CEN/TR 14819-2:2005
(Main)Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations
Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations
This part of the technical report specifies safety recommendations applicable to the prevention and fighting of
fires in funicular railways not in tunnels, aerial ropeways and ski-tows that may endanger the health and safety
of persons.
With regard to funicular railways, these recommendations are applicable to those not running in a tunnel and
having a pathway alongside the track that does not allow passengers to exit the carrier in less than 5 min. For
funicular railways where evacuation of the carrier can be completed within 5 min, the same recommendations
may be applied in part according to the results of the safety analysis of the installation.
With regard to these problems of fire, it is essential to take organizational measures relating to operation, but
these are not covered in this report.
Requirements for aerial ropeways operating in a tunnel may also be based on CEN/TR 14819-1.
Sicherheitsempfehlungen für Seilbahnen für den Personenverkehr - Brandverhütung und -bekämpfung - Teil 2: Andere Standseil- und Seilbahnen
Recommandations de sécurité pour les installations à câbles transportant des personnes - Prévention et lutte contre les incendies - Partie 2 : Autres funiculaires et autres installations
La présente partie du rapport technique établit les recommandations de sécurité s'appliquant à la prévention et à la lutte contre l'incendie des funiculaires sans tunnel, des téléphériques et des téléskis pouvant mettre en danger la sécurité et la santé des personnes.
Concernant les funiculaires, ces recommandations sont applicables à ceux ne possédant pas de tunnel, et dont le cheminement le long de la voie ne permet pas une sortie des passagers du véhicule en moins de 5 minutes. Pour les funiculaires dont l'évacuation du véhicule se fait en moins de 5 minutes, les mêmes recommandations peuvent être appliquées en partie suivant les résultats de l'étude de sécurité de l'installation.
Vis à vis de ces problèmes d'incendie, il est nécessaire de prendre des mesures d'organisation qui relèvent de l'exploitation mais ceci n'est pas traité dans le présent rapport.
Les téléphériques fonctionnant en tunnel pourront aussi s'inspirer du CEN/TR 14819-1.
Varnostna priporočila za žičniške naprave za prevoz oseb – Preprečevanje in gašenje požara – 2. del: Ostale tirne vzpenjače in druge žičniške naprave
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2006
9DUQRVWQDSULSRURþLOD]DåLþQLãNHQDSUDYH]DSUHYR]RVHE±3UHSUHþHYDQMHLQ
JDãHQMHSRåDUD±GHO2VWDOHWLUQHY]SHQMDþHLQGUXJHåLþQLãNHQDSUDYH
Safety recommendations for cableway installations designed to carry persons -
Prevention and fight against fire - Part 2: Other funicular railways and other installations
Sicherheitsempfehlungen für Seilbahnen für den Personenverkehr - Brandverhütung und
-bekämpfung - Teil 2: Andere Standseil- und Seilbahnen
Recommandations de sécurité pour les installations a câbles transportant des personnes
- Prévention et lutte contre les incendies - Partie 2 : Autres funiculaires et autres
installations
Ta slovenski standard je istoveten z: CEN/TR 14819-2:2005
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
45.100 2SUHPD]DåLþQLFH Cableway equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
TECHNICAL REPORT
CEN/TR 14819-2
RAPPORT TECHNIQUE
TECHNISCHER BERICHT
November 2005
ICS 13.220.20; 45.100
English Version
Safety recommendations for cableway installations designed to
carry persons - Prevention and fight against fire - Part 2: Other
funicular railways and other installations
Recommandations de sécurité pour les installations à Sicherheitsempfehlungen für Seilbahnen für den
câbles transportant des personnes - Prévention et lutte Personenverkehr - Brandverhütung und -bekämpfung - Teil
contre les incendies - Partie 2 : Autres funiculaires et 2: Andere Standseil- und Seilbahnen
autres installations
This Technical Report was approved by CEN on 29 August 2005. It has been drawn up by the Technical Committee CEN/TC 242.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 14819-2:2005: E
worldwide for CEN national Members.
Contents Page
Foreword .4
Introduction.5
1 Scope.6
2 Normative references.6
3 Terms and definitions .7
4 General recommendations.8
4.1 Application of this technical report .8
4.2 Safety principles.8
4.2.1 General.8
4.2.2 Hazard scenarios.8
4.2.3 Safety measures.8
5 Basic recommendations .9
6 Recommendations concerning fire prevention and firefighting in carriers.10
6.1 Materials .10
6.2 Electrical cabinets.10
6.3 Cabling outside the electrical cabinets and lighting.11
6.4 Batteries.11
6.5 Battery chargers.11
6.6 Video equipment (camera, monitor) .11
6.7 Heating, air conditioning.11
6.8 Electrical components outside cabinets which are energized during travel (dynamos,
alternators, motors).11
6.9 Pantographs .12
6.10 Rail brake – Retarder.12
6.11 Hydraulic power plants and circuits – Pressure vessels – Refrigerants .12
6.12 Prohibition of smoking, open fires and the transportation of flammable materials.12
6.13 Extinguishers and other means of firefighting .12
6.14 Capacity of carriers.13
6.15 Recovery measures in the event of a fire on board a carrier .13
6.16 Emergency exits from carriers .13
7 Recommendations concerning fire prevention and firefighting in the area of the line.13
7.1 Rails and overhead catenaries supplying auxiliary electrical power to carriers.13
7.2 Transmission of electrical power along the track or supported by line support structures.14
7.3 Remote communication cable between carrier and control point .14
7.4 Transportation of flammable liquid along the funicular railway track .14
7.5 Track or route of line.14
8 Recommendations concerning fire prevention and firefighting in stations.15
8.1 General.15
8.2 Platform materials .15
8.3 Maintenance pit beneath carriers at the platform .16
8.4 Space adjacent to the platforms.16
8.5 Transmission of electrical power .16
8.6 Contacts for recharging the carrier batteries.16
8.7 Video equipment (camera, monitor) .16
8.8 Dispensing machines for use by passengers and other platform furniture.17
8.9 Prohibition of smoking, open fires and the transportation of flammable materials.17
8.10 Extinguishers.17
8.11 Smoke detection and clearing. 17
9 Recommendations concerning fire prevention and firefighting in the machine room and
electrical power system spaces. 17
9.1 Prevention. 17
9.2 Limitation of spread of fire. 17
10 Recommendations concerning fire prevention and firefighting in electrical supply spaces. 18
11 Recommendations concerning fire prevention and firefighting in the control room. 18
11.1 Civil engineering. 18
11.2 Spaces adjacent to the control point. 19
11.3 Electrical equipment. 19
11.4 Video monitors . 19
11.5 Space heating .19
11.6 Domestic utensils. 19
11.7 Furniture . 19
11.8 Putting safety devices out of service. 19
11.9 Personnel. 20
12 Lightning. 20
13 Training of personnel . 20
14 Maintenance. 20
Bibliography. 21
Foreword
This Technical Report (CEN/TR 14819-2:2005) has been prepared by Technical Committee CEN/TC 242
“Safety requirements for passenger transportation by rope”, the secretariat of which is held by AFNOR.
CEN/TR 14819 comprises the following parts presented under the general title of Safety recommendations for
cableway installations designed to carry persons - Prevention and fight against fire:
Part 1: Funicular railways in tunnels
Part 2: Other funicular railways and other installations
This technical report forms part of the standards programme approved by the CEN Technical Board (CEN/BT)
on safety requirements for cableway installations designed to carry persons:
1 Safety requirements for cableway installations designed to carry persons - Terminology
2 Safety requirements for cableway installations designed to carry persons - General requirements
3 Safety requirements for cableway installations designed to carry persons - Calculations
4 Safety requirements for cableway installations designed to carry persons - Ropes
5 Safety requirements for cableway installations designed to carry persons - Tensioning devices
6 Safety requirements for cableway installations designed to carry persons - Drive systems and other
mechanical equipment
7 Safety requirements for cableway installations designed to carry persons - Carriers
8 Safety requirements for cableway installations designed to carry persons - Electrical equipment other
than for drive systems
9 Safety requirements for cableway installations designed to carry persons - Civil engineering works
10 Safety requirements for cableway installations designed to carry persons – Pre-commissioning inspection,
maintenance and operational inspection and checks
11 Safety requirements for cableway installations designed to carry persons – Recovery and evacuation
12 Safety requirements for cableway installations designed to carry persons - Operation
13 Safety requirements for cableway installations designed to carry persons - Quality assurance
Together these form a series of standards regarding design, manufacture, construction, maintenance and
operation of all cableway installations designed to carry persons.
Introduction
This draft report has been prepared by a working group set up by TC 242 "Safety requirements for passenger
transportation by rope". It responds to a request by the European Commission and CEN and will be of use to
operators and designers of installations other than funicular railways in tunnels covered by CEN/TR 14819-1.
1 Scope
This part of the technical report specifies safety recommendations applicable to the pre
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.