Test Method for Determining Open Assembly Time of Carpet Mastic Adhesives

SCOPE
1.1 This test method describes a procedure to measure open assembly time for a troweled carpet adhesive.
1.2 This test method provides an evaluation of the ability of an adhesive to effectively wet out the intended carpet backing.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Sep-1998
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6325-98 - Test Method for Determining Open Assembly Time of Carpet Mastic Adhesives
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6325 – 98
Test Method for
Determining Open Assembly Time of Carpet Mastic
Adhesives
This standard is issued under the fixed designation D 6325; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 4.2 The test method provides a means of measuring the
open assembly time for an adhesive. Use of such a test method
1.1 This test method describes a procedure to measure open
can aid both the manufacturer to develop and the user to select
assembly time for a troweled carpet adhesive.
the appropriate adhesive for the installation of carpet.
1.2 This test method provides an evaluation of the ability of
4.3 Test Method C 679 was used as a model for this test
an adhesive to effectively wet out the intended carpet backing.
method.
1.3 The values stated in inch-pound units are to be regarded
as the standard. The values given in parentheses are for
5. Apparatus
information only.
1 1
5.1 Applicator Trowel— ⁄8 in. (3.2 mm) wide, ⁄8in. (3.2
1.4 This standard does not purport to address all of the
mm) deep, ⁄16 in. (1.6 mm) space V-notch.
safety concerns, if any, associated with its use. It is the
5.2 One-kg Weight, at least 2 in. (51 mm) in diameter.
responsibility of the user of this standard to establish appro-
5.3 Chronometer.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
6. Materials
2. Referenced Documents 6.1 Adhesive—Any appropriate adhesive used to install
carpet.
2.1 ASTM Standards:
6.2 Polyethylene—Low density (LDPE) with a 0.006 in.
C 679 Test Method for Tack-Free Time of Elastomeric
2 (0.15 mm) thickness.
Sealants
6.3 Glass, 12 in. by 12 in.
D 618 Practice for Conditioning Plastics for Testing
D 907 Terminology of Adhesives
7. Conditioning
7.1 Condition the LDPE, glass, and adhesive to be tested 24
3. Terminology
h prior to testing at 73.4 6 3.6°F (23 6 2°C) and 50 6 5%
3.1 Definitions:
relative humidity according to Practice D 618.
3.1.1 Many of the terms in this test method are defined in
Terminology D 907.
8. Sample Preparation
8.1 Cut the LDPE into twenty 2 in. (50.8 mm) by 2 in. (50.8
4. Significance and Use
mm) pieces.
4.1 The ability to have a sufficient open assembly time is
critical when bonding a carpet. An adhesive with too short an
9. Procedure
open assembly time will not allow the installer enough time to
9.1 Hold the trowel at a 45° angle and spread enough
position the carpet before the adhesive is dried beyond use. A
adhesive to cover the entire glass surface. Start the c
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.