M/575 AMD 1 - Medical Devices (MDR-IVDR)
Medical devices in support of Regulation (EU) 2017/745 and in vitro diagnostic medicial devices in support of Regulation (EU) 2017746
General Information
Frequently Asked Questions
A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.
M/575 AMD 1 is a European Standardization Mandate titled "Medical devices in support of Regulation (EU) 2017/745 and in vitro diagnostic medicial devices in support of Regulation (EU) 2017746". Medical devices in support of Regulation (EU) 2017/745 and in vitro diagnostic medicial devices in support of Regulation (EU) 2017746 There are 18 standards developed under this mandate.
Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.
2022-05-21-JO- to ensure continuity, HAS assessment should be prepared by Tony Wilkes
- Amendment14 pagesEnglish languagee-Library read for1 day
2022-05-21-JO- to ensure continuity, HAS assessment should be prepared by Tony Wilkes
- Amendment14 pagesEnglish languagee-Library read for1 day
1.1 This document specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only.
These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities.
1.2 This document specifies minimum requirements:
- for the performance and design of sterilizers intended to deliver an LTSF process capable of sterilizing medical devices;
- for the equipment and controls of these sterilizers which are needed for operation, control and monitoring of the sterilization processes, and which can be used for validation of the sterilization process.
1.3 This document specifies further test equipment and test procedures used to verify conformance of the equipment design and performance specified by this document.
1.4 This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.
- Standard127 pagesEnglish languagee-Library read for1 day
1.1 This document specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only.
These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities.
1.2 This document specifies minimum requirements:
- for the performance and design of sterilizers intended to deliver an LTSF process capable of sterilizing medical devices;
- for the equipment and controls of these sterilizers which are needed for operation, control and monitoring of the sterilization processes, and which can be used for validation of the sterilization process.
1.3 This document specifies further test equipment and test procedures used to verify conformance of the equipment design and performance specified by this document.
1.4 This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.
- Standard127 pagesEnglish languagee-Library read for1 day
IEC 60118-0:2022 gives recommendations for the measurement of the performance characteristics of air conduction hearing aids measured with an acoustic coupler or occluded ear simulator.
This document is applicable to the measurement and evaluation of the electroacoustical characteristics of hearing aids, for example for type testing and manufacturer data sheets.
This document is also applicable for the measurement of the performance characteristics of hearing aids for production, supply and delivery quality-assurance purposes.
The measurement results obtained by the methods specified in this document will express the performance under conditions of the measurement and can deviate substantially from the performance of the hearing aid under actual conditions of use.
This document primarily uses an acoustic coupler according to IEC 60318-5 which is only intended for loading a hearing aid with specified acoustic impedance and is not intended to reproduce the sound pressure in a person's ear. For measurements reflecting the output level in the normal human ear the occluded ear simulator according to IEC 60318-4 can be used. For extended high-frequency measurements and for deep insert hearing aids, the acoustic coupler according to IEC 60318-8 can be used.
This document also covers measurement of hearing aids with non-acoustic inputs, such as wireless, inductive or electrical input.
This document does not cover the measurement of hearing aids for simulated in situ working conditions, for which IEC 60118-8 can be applied.
This document does not cover the measurement of hearing aids under typical user settings and using a speech-like signal, for which IEC 60118-15 can be applied.
IEC 60118-0:2022 merges and updates the methods previously described in IEC 60118-0:2015 and IEC 60118-7:2005. It cancels and replaces the third edition of IEC 60118-0 published in 2015. This edition constitutes a technical revision.
Measurements for quality control as described in IEC 60118-7:2005 can be found in Clause 10 of this document.
This edition includes the following significant technical changes with respect to previous editions:
a) the default use of an acoustic coupler according to IEC 60318-5,
b) addition of the optional use of an occluded ear simulator according to IEC 60318-4,
c) addition of the optional use of an acoustic coupler according to IEC 60318-8 (new standard based on IEC TS 62886) when information about the response above 8 kHz is needed, or the optional use of the acoustic coupler according to IEC 60318-8 for deep insert hearing aids,
d) the addition of measurements of the performance of hearing aids for production, supply and delivery quality assurance purposes,
e) corrected and updated measurement configuration and methods, adding the use of a sequential measurement as preferred configuration,
f) updated and expanded measurement procedures for the non-acoustic inputs of the hearing aid.
- Standard77 pagesEnglish languagee-Library read for1 day
IEC 60118-0:2022 gives recommendations for the measurement of the performance characteristics of air conduction hearing aids measured with an acoustic coupler or occluded ear simulator. This document is applicable to the measurement and evaluation of the electroacoustical characteristics of hearing aids, for example for type testing and manufacturer data sheets. This document is also applicable for the measurement of the performance characteristics of hearing aids for production, supply and delivery quality-assurance purposes. The measurement results obtained by the methods specified in this document will express the performance under conditions of the measurement and can deviate substantially from the performance of the hearing aid under actual conditions of use. This document primarily uses an acoustic coupler according to IEC 60318-5 which is only intended for loading a hearing aid with specified acoustic impedance and is not intended to reproduce the sound pressure in a person's ear. For measurements reflecting the output level in the normal human ear the occluded ear simulator according to IEC 60318-4 can be used. For extended high-frequency measurements and for deep insert hearing aids, the acoustic coupler according to IEC 60318-8 can be used. This document also covers measurement of hearing aids with non-acoustic inputs, such as wireless, inductive or electrical input. This document does not cover the measurement of hearing aids for simulated in situ working conditions, for which IEC 60118-8 can be applied. This document does not cover the measurement of hearing aids under typical user settings and using a speech-like signal, for which IEC 60118-15 can be applied. IEC 60118-0:2022 merges and updates the methods previously described in IEC 60118-0:2015 and IEC 60118-7:2005. It cancels and replaces the third edition of IEC 60118-0 published in 2015. This edition constitutes a technical revision. Measurements for quality control as described in IEC 60118-7:2005 can be found in Clause 10 of this document. This edition includes the following significant technical changes with respect to previous editions: a) the default use of an acoustic coupler according to IEC 60318-5, b) addition of the optional use of an occluded ear simulator according to IEC 60318-4, c) addition of the optional use of an acoustic coupler according to IEC 60318-8 (new standard based on IEC TS 62886) when information about the response above 8 kHz is needed, or the optional use of the acoustic coupler according to IEC 60318-8 for deep insert hearing aids, d) the addition of measurements of the performance of hearing aids for production, supply and delivery quality assurance purposes, e) corrected and updated measurement configuration and methods, adding the use of a sequential measurement as preferred configuration, f) updated and expanded measurement procedures for the non-acoustic inputs of the hearing aid.
- Standard77 pagesEnglish languagee-Library read for1 day
Contains requirements concerning basic safety and essential performance that are generally applicable to medical electrical equipment. For certain types of medical electrical equipment, these requirements are either supplemented or modified by the special requirements of a collateral or particular standard. Where particular standards exist, this standard should not be used alone. The contents of the corrigenda of December 2006, of July 2007, the interpretation sheet 1 of April 2008, the interpretation sheet 2 of January 2009 and the interpretation sheet 2 of May 2013 have been included in this copy.
- Amendment48 pagesEnglish languagee-Library read for1 day
Contains requirements concerning basic safety and essential performance that are generally applicable to medical electrical equipment. For certain types of medical electrical equipment, these requirements are either supplemented or modified by the special requirements of a collateral or particular standard. Where particular standards exist, this standard should not be used alone. The contents of the corrigenda of December 2006, of July 2007, the interpretation sheet 1 of April 2008, the interpretation sheet 2 of January 2009 and the interpretation sheet 2 of May 2013 have been included in this copy.
- Amendment48 pagesEnglish languagee-Library read for1 day
2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.
- Amendment23 pagesEnglish languagee-Library read for1 day
2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.
- Amendment23 pagesEnglish languagee-Library read for1 day
This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized.
It does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.
It does not describe a quality assurance system for control of all stages of manufacture.
It does not apply to packaging materials and/or systems used to contain a contaminated medical device during transportation of the item to the site of reprocessing or disposal.
- Standard52 pagesEnglish languagee-Library read for1 day
This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems.
It is applicable to industry, to health care facilities, and to wherever medical devices are packaged and sterilized.
It does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.
- Standard21 pagesEnglish languagee-Library read for1 day
This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems.
It is applicable to industry, to health care facilities, and to wherever medical devices are packaged and sterilized.
It does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.
- Standard21 pagesEnglish languagee-Library read for1 day
This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized.
It does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements can be necessary for drug/device combinations.
It does not describe a quality assurance system for control of all stages of manufacture.
It does not apply to packaging materials and/or systems used to contain a contaminated medical device during transportation of the item to the site of reprocessing or disposal.
- Standard52 pagesEnglish languagee-Library read for1 day
This document specifies requirements and tests for low temperature hydrogen peroxide sterilizers, which use a vaporized aqueous solution of hydrogen peroxide as the sterilizing agent.
These sterilizers are used for the sterilization of medical devices, particularly thermolabile medical devices.
This document specifies minimum requirements
• for the performance and design of sterilizers intended to deliver a process capable of sterilizing medical devices;
• for the equipment and controls of these sterilizers needed for operation, control and monitoring, and which can be used for validation of the sterilization processes;
• for the test equipment and test procedures used to verify the sterilizer performance specified by this document.
This document does not specify requirements for equipment intended to process liquids, biological waste, or human tissues.
This document does not describe a quality management system for the control of all stages of the manufacture of the sterilizer.
This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.
NOTE 1 Attention is drawn to the standards for quality management, e.g. EN ISO 13485.
NOTE 2 Environmental aspects of this standard are addressed in Annex H.
- Draft125 pagesEnglish languagee-Library read for1 day
This document specifies requirements and tests for low temperature hydrogen peroxide sterilizers, which use a vaporized aqueous solution of hydrogen peroxide as the sterilizing agent.
These sterilizers are used for the sterilization of medical devices, particularly thermolabile medical devices.
This document specifies minimum requirements
• for the performance and design of sterilizers intended to deliver a process capable of sterilizing medical devices;
• for the equipment and controls of these sterilizers needed for operation, control and monitoring, and which can be used for validation of the sterilization processes;
• for the test equipment and test procedures used to verify the sterilizer performance specified by this document.
This document does not specify requirements for equipment intended to process liquids, biological waste, or human tissues.
This document does not describe a quality management system for the control of all stages of the manufacture of the sterilizer.
This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.
NOTE 1 Attention is drawn to the standards for quality management, e.g. EN ISO 13485.
NOTE 2 Environmental aspects of this standard are addressed in Annex H.
- Draft125 pagesEnglish languagee-Library read for1 day
This European Standard specifies requirements and the relevant tests for large steam sterilizers primarily used in health care for the sterilization of medical devices and their accessories contained in one or more sterilization modules. The test loads described in this European Standard are selected to represent the majority of loads (i.e. wrapped goods consisting of metal, rubber and porous materials) for the evaluation of general purpose steam sterilizers for medical devices. However, specific loads (e.g. heavy metal objects or long and/or narrow lumen) will require the use of other test loads.
This European Standard applies to steam sterilizers designed to accommodate at least one sterilization module or having a chamber volume of at least 60 l.
Large steam sterilizers can also be used during the commercial production of medical devices.
This European Standard does not specify requirements for equipment intended to use, contain or be exposed to flammable substances or substances which could cause combustion. This European Standard does not specify requirements for equipment intended to process biological waste or human tissues.
This European Standard does not describe a quality management system for the control of all stages of the manufacture of the sterilizer.
NOTE 1 Attention is drawn to the standards for quality management systems e.g. EN ISO 13485.
NOTE 2 Environmental aspects are addressed in Annex A.
- Draft4 pagesEnglish languagee-Library read for1 day
This European Standard specifies requirements and the relevant tests for large steam sterilizers primarily used in health care for the sterilization of medical devices and their accessories contained in one or more sterilization modules. The test loads described in this European Standard are selected to represent the majority of loads (i.e. wrapped goods consisting of metal, rubber and porous materials) for the evaluation of general purpose steam sterilizers for medical devices. However, specific loads (e.g. heavy metal objects or long and/or narrow lumen) will require the use of other test loads.
This European Standard applies to steam sterilizers designed to accommodate at least one sterilization module or having a chamber volume of at least 60 l.
Large steam sterilizers can also be used during the commercial production of medical devices.
This European Standard does not specify requirements for equipment intended to use, contain or be exposed to flammable substances or substances which could cause combustion. This European Standard does not specify requirements for equipment intended to process biological waste or human tissues.
This European Standard does not describe a quality management system for the control of all stages of the manufacture of the sterilizer.
NOTE 1 Attention is drawn to the standards for quality management systems e.g. EN ISO 13485.
NOTE 2 Environmental aspects are addressed in Annex A.
- Draft4 pagesEnglish languagee-Library read for1 day