This document defines procedures for determining the standard thermal outputs and other characteristics of radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source. This document specifies the laboratory arrangements and testing methods to be adopted, the admissible tolerances, the criteria for selecting the samples to be tested and for verifying the conformity of the current production with the samples tested at the initial test. This document also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products. This document does not apply to fan-assisted radiators, fan-assisted convectors and trench convectors or to independent heating appliances.

  • Standard
    64 pages
    English language
    sale 15% off

This document specifies procedures and conditions to enable the heat flux in water-based surface heating and cooling systems to be determined relative to the medium differential temperature for systems. The determination of thermal performance of water-based surface heating and cooling systems and their conformity to this document is carried out by calculation in accordance with design documents and a model. This enables a uniform assessment and calculation of water-based surface heating and cooling systems. The surface temperature and the temperature uniformity of the heated/cooled surface, nominal heat flux between water and space, the associated nominal medium differential temperature, and the field of characteristic curves for the relationship between heat flux and the determining variables are given as the result. This document includes a general method based on finite difference or finite element Methods and simplified calculation methods depending on position of pipes and type of building structure.

  • Standard
    57 pages
    English language
    sale 15% off
  • Standard
    59 pages
    French language
    sale 15% off

This document establishes requirements for the installation of embedded radiant heating and cooling systems. It specifies general and uniform requirements for the design and construction of heating and cooling floors, ceiling and wall structures to ensure that the heating/cooling systems are suited to the particular application. The requirements specified by this document are applicable only to the components of the heating/cooling systems and the elements which are part of the heating/cooling surface and which are installed due to the heating/cooling systems. This document is applicable to water-based embedded surface heating and cooling systems in residential, commercial and industrial buildings. The methods apply to systems integrated into the wall, floor or ceiling construction without any open-air gaps, but are not applicable to panel systems with open-air gaps which are not integrated into the building structure.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

This document establishes a system design and dimensioning method to ensure the heating and cooling capacity of the radiant heating and cooling systems.

  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off

This document allows the calculation of peak cooling capacity of Thermo Active Building Systems (TABS) – Type V according to ISO 11855-1, based on heat gains, such as solar gains, internal heat gains, and ventilation, and the calculation of the cooling power demand on the water side, to be used to size the cooling system, as regards, e.g. the chiller size, fluid flow rate. This document defines a detailed method aimed at the calculation of heating and cooling capacity in non-steady state conditions.

  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    59 pages
    French language
    sale 15% off

This document specifies the basic definitions, symbols, and comfort criteria for embedded radiant heating and cooling systems.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off

This document specifies procedures and conditions to enable the heat flow in water-based and electrical surface heating and cooling systems to be determined relative to the medium differential temperature for systems. The determination of thermal performance of water-based surface heating and cooling systems and their conformity to this document is carried out by calculation in accordance with design documents and a model. This enables a uniform assessment and calculation of water-based surface heating and cooling systems. The surface temperature and the temperature uniformity of the heated/cooled surface, nominal heat flow density between water or electrical heated layer and space, the associated nominal medium differential temperature, and the field of characteristic curves for the relationship between heat flow density and the determining variables are given as the result. This document is applicable to water-based embedded surface heating and cooling systems in residential, commercial and industrial buildings. This document is also applicable for electrical heated embedded systems. The methods apply to systems integrated into the wall, floor or ceiling construction without any open air gaps. It does not apply to ceiling mounted panel systems with open air gaps which are not integrated into the building structure.

  • Standard
    7 pages
    English language
    sale 15% off

This document establishes guidelines for the determination of input parameters for ceiling mounted radiant heating and cooling panels in relation to ISO 52031. The requirements specified by this document are applicable only to the components of the heating/cooling systems and the elements which are part of the heating/cooling panels and which are installed to provide heating and/or cooling. This document is applicable to water-based ceiling mounted radiant heating and cooling panels in residential, commercial and industrial buildings. The methods apply to systems mounted under the ceiling with an open air gap between the panels and the ceiling. This document also applies, as appropriate, to the use of fluids other than water as a heating or cooling medium. This document is also applicable for testing of systems. The methods do not apply to heated or chilled ceiling beams.

  • Standard
    6 pages
    English language
    sale 15% off

This document establishes guidelines for the control of embedded radiant heating and cooling systems. It specifies uniform requirements for the design and construction of heating and cooling floors, ceiling and wall structures to ensure that the heating/cooling systems are suited to the particular application. The requirements specified in this document are applicable only to the components of the heating/cooling systems and the elements which are part of the heating/cooling surface and which are installed due to the heating/cooling systems. This document is applicable to water-based embedded surface heating and cooling systems in residential, commercial and industrial buildings. The methods apply to systems integrated into the wall, floor or ceiling construction without any open air gaps. It is not applicable to panel systems with an open air gap which is not integrated with the building structure. This document also applies, as appropriate, to the use of fluids other than water as a heating or cooling medium. This document is not applicable for testing of systems. The methods do not apply to heated or chilled ceiling panels or beams.

  • Standard
    13 pages
    English language
    sale 15% off

ISO 18566-4:2017 specifies the control of ceiling mounted radiant heating and cooling panels. The requirements in this document are applicable only to the components of the heating/cooling systems and the elements which are part of the heating/cooling panels and which are installed to provide heating and/or cooling. ISO 18566-4:2017 is applicable to water-based ceiling mounted radiant heating and cooling panels in residential, commercial and industrial buildings. The methods apply to systems mounted under the ceiling with or without open air gaps between the panels and the ceiling.

  • Standard
    8 pages
    English language
    sale 15% off

ISO 18566-3:2017 specifies the design of ceiling mounted radiant panels. ISO 18566-3:2017 is applicable to water-based heating and cooling panel systems (free hanging) in residential, commercial and industrial buildings. The methods apply to systems mounted to the ceiling construction with an open air gap. ISO 18566-3:2017 applies to all types of prefabricated radiant panels that are part of the room periphery. ISO 18566-3:2017 does not cover panels embedded into ceiling, wall or floor structures without open air gap and hybrid (combined thermal radiation and forced-convection) ceiling panels.

  • Standard
    14 pages
    English language
    sale 15% off

ISO 18566-2:2017 dry cooling only surfaces with an air gap between construction and the emitter (not embedded) with or without an insulation fed with water at temperatures below 120 °C connected with a centralized heating and/or cooling supply source intended to be installed in buildings. Ceiling mounted radiant panels covered by this document are limited to a width from 0,3 m up to 1,5 m. ISO 18566-2:2017 also defines the additional common data that the manufacturer provides to the trade, in order to ensure the correct application of the products.

  • Standard
    17 pages
    English language
    sale 15% off

ISO 18566-1:2017 specifies the design, test conditions and methods for the determination of the cooling and heating capacity and control of radiant heating and cooling panels with an open air gap. This document applies to all types of prefabricated radiant panels that are part of the room periphery such as ceiling, walls and floor. ISO 18566-1:2017 is applicable to water-based heating and cooling panel systems (free hanging) in residential, commercial and industrial buildings. The methods apply to systems mounted to the wall, floor or ceiling construction with an open air gap. ISO 18566-1:2017 does not cover panels embedded into ceiling, wall or floor structures and hybrid (combined thermal radiation and forced-convection) ceiling panels. ISO 18566-1:2017 specifies the definition, symbols, comfort criteria, technical specifications and requirements of ceiling mounted radiant panels.

  • Standard
    26 pages
    English language
    sale 15% off