SC 59M - Performance of electrical household and similar cooling and freezing appliances
Standardization in the field of performance of electrical household and similar cooling and freezing appliances such as refrigerators, frozen-food storage cabinets and food freezers. To elaborate characteristics and test methods for performance, environmental issues and accessibility. This includes specifying the essential characteristics for commercial refrigerating appliances cooled by internal natural convection or forced air circulation, which are factory assembled, laying down the methods of test for the checking of these characteristics.
Aptitude à la fonction des appareils électrodomestiques de refroidissement et analogues et appareils de réfrigération
Normalisation dans le domaine de l’aptitude à la fonction des appareils électrodomestiques de refroidissement et analogues et des appareils frigorifiques tels que les réfrigérateurs, les conservateurs de denrées congelées et les congélateurs. Elaboration des caractéristiques et des méthodes d'essai pour l’aptitude à la fonction, les questions environnementales et l'accessibilité. Cela inclut la spécification des caractéristiques essentielles pour les appareils de réfrigération à usage commercial refroidis par une convection interne naturelle ou par une circulation d’air forcée, qui sont assemblés en usine, avec détermination des méthodes d'essai pour la vérification de ces caractéristiques.
General Information
- Standard34 pagesEnglish and French languagesale 15% off
IEC 63169:2020 deals with a test to simulate the weight loss of leafy produce, given certain conditions of temperature, humidity and air movement in one or more test zones. The test can only be applied to spaces larger than 200 mm × 150 mm ×100 mm (L × W × H).
The aim of the test is to measure the weight loss rate by measuring the weight of a test tray prior to the test and after a given duration.
Weight loss is one of the considerations for shelf life of produce. Other considerations such as condensation will be addressed in future amendments.
- Standard60 pagesEnglish languagesale 15% off
- Standard37 pagesEnglish and French languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60704-2-14:2013 specifies the measuring conditions to provide for sufficient accuracy in determining the noise emitted and comparing the results of measurements taken by different laboratories, whilst simulating as far as possible the practical use of household refrigerators, frozen-food storage cabinets and food freezers. It is recommended to consider the determination of noise levels as part of a comprehensive testing procedure covering many aspects of the properties and performance of household refrigerators, frozen-food storage cabinets and food freezers. This edition includes the following significant technical changes with respect to the previous edition:
a) the description of an appropriate test enclosure has been removed from this part of IEC 60704 and has been incorporated into Part 1 of IEC 60704-1;
b) the values of standard deviations of sound power levels determined according to this part of IEC 60704 have been added.
This publication is to be read in conjunction with IEC 60704-1:2010.
- Standard14 pagesEnglish languagesale 15% off
- Standard28 pagesEnglish and French languagesale 15% off
- Standard59 pagesEnglish and French languagesale 15% off
- Standard62 pagesEnglish and French languagesale 15% off
IEC 62552-1:2015 specifies the essential characteristics of household refrigerating appliances, cooled by internal natural convection or forced air circulation, and establishes test methods for checking the characteristics. For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to be type tests to assess the fundamental design and operation of a refrigerating appliance. This part of IEC 62552 does not define requirements for production sampling or conformity assessment or certification. This part of IEC 62552 does not define a regime for verification testing as this varies by region and country. When verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary, it is preferable, wherever practicable, that all the tests specified be applied to a single unit. The tests can also be made individually for the study of a particular characteristic. IEC 62552-1, -2 and -3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, -2 and -3 constitute a technical revision and includes the following significant technical changes with respect to IEC 62552:2007:
a) All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment.
b) In Part 1 (this part) there are some changes to test room equipment specifications and the setup for testing to provide additional flexibility especially when testing multiple appliances in a single test room.
- Standard129 pagesEnglish and French languagesale 15% off
- Standard363 pagesEnglish and French languagesale 15% off
IEC 62552-3:2015 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics. This part of IEC 62552 describes the methods for the determination of energy consumption characteristics and defines how these can be assembled to estimate energy consumption under different usage and climate conditions. This part of IEC 62552 also defines the determination of volume.
- All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment.
- For more efficient analysis and to better characterise the key product characteristics under different operating conditions, the test data from many of the energy tests in Part 3 (this part) is now split into components (such as steady state operation and defrost and recovery). The approach to determination of energy consumption has been completely revised, with many internal checks now included to ensure that data complying with the requirements of the standard is as accurate as possible and of high quality.
- Part 3 (this part) now provides a method to quantify each of the relevant energy components and approaches on how these can be combined to estimate energy under different conditions on the expectation that different regions will select components and weightings that are most applicable when setting both their local performance and energy efficiency criteria while using a single set of global test measurements.
- For energy consumption measurements in Part 3 (this part), no thermal mass (test packages) is included in any compartment and compartment temperatures are based on the average of air temperature sensors (compared to the temperature in the warmest test package). There are also significant differences in the position of temperature sensors in unfrozen compartments.
- The energy consumption test in Part 3 (this part) now has two specified ambient temperatures (16°C and 32°C).
- A load processing energy efficiency test has been added in Part 3 (this part).
- Tests (both performance (Part 2) and energy (Part 3 (this part)) have been added for wine storage appliances.
- Standard328 pagesEnglish and French languagesale 15% off
- Standard679 pagesEnglish and French languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
IEC 62552-2:2015 specifies the essential characteristics of household refrigerating appliances cooled by internal natural convection or forced air circulation, and specifies test methods for checking the characteristics. This part of IEC 62552 describes the methods for the determination of performance requirements. Although there is some commonality in the set-ups for different tests (and so it may be an advantage to apply them all to one sample), these are separate tests to evaluate specific characteristics of the sample being tested. This part of IEC 62552 does not specify a procedure to generalise the results from sample test results to a prediction of the characteristics of the whole population from which that sample was selected. IEC 62552-1, IEC 62552-2 and IEC 62552-3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, IEC 62552-2 and IEC 62552-3 together constitute a technical revision and include the following significant technical changes with respect to IEC 62552:2007:
- A cooling capacity test has been added in Part 2 (this part).
- A pull-down test has been added in Part 2 (this part).
- Performance tests have been added for wine storage appliances in Part 2 (this part).
- Standard86 pagesEnglish and French languagesale 15% off
- Standard191 pagesEnglish and French languagesale 15% off
- Standard30 pagesEnglish and French languagesale 15% off
- Standard79 pagesEnglish and French languagesale 15% off
- Standard8 pagesEnglish and French languagesale 15% off
IEC TR 63061:2017(E) sets out a uniform calculation method for the parameter of adjusted volume that is commonly employed in the calculation of energy efficiency household refrigerators, freezers and refrigerator-freezers.
- Technical report16 pagesEnglish languagesale 15% off
Specifies methods for measuring airborne acoustical noise emitted by electric refrigerators, frozen-food storage cabinets, food freezers and their combinations for household and similar uses, supplied from the mains or from batteries. This standard does not apply to appliances, equipment or machines designed exclusively for industrial or commercial purposes.
- Standard21 pagesEnglish and French languagesale 15% off
- Standard10 pagesEnglish and French languagesale 15% off
Specifies the essential characteristics of household refrigerating appliances, factory-assembled and cooled by internal natural convection or forced air circulation, and establishes test methods for checking the characteristics. These are type tests, and because of this, when verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary, it is preferable, wherever practicable, that all the tests specified be applied to a single unit. The tests can also be made individually for the study of a particular characteristic. The contents of the corrigendum of March 2008 have been included in this copy.
- Standard173 pagesEnglish and French languagesale 15% off