SIST ETS 300 329 E1:2005
(Main)Radio Equipment and Systems (RES); Electro-Magnetic Compatibility (EMC) for Digital European Cordless Telecommunications (DECT) equipment
- Abstract
Covers the EMC requirements for DECT equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
- Status
- Published
- Publication Date
- 31-Jan-2005
- Technical Committee
- RES - Radio equipment and systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-2005
- Due Date
- 01-Feb-2005
- Completion Date
- 01-Feb-2005
SIST ETS 300 329 E1:2005 is the Slovenian standard for the electro-magnetic compatibility (EMC) of Digital European Cordless Telecommunications (DECT) equipment, published by SIST and identical to ETS 300 329 Edition 1 from ETSI. It specifies the EMC tests, limits and performance criteria for DECT radio equipment and associated ancillary equipment operating in the 1 880 MHz to 1 900 MHz band. In practice, it is used when a DECT product needs evidence of EMC performance for the Council Directive 89/336/EEC.
What does SIST ETS 300 329 E1:2005 specify?
SIST ETS 300 329 E1:2005 covers the assessment of DECT radio communication equipment and ancillary equipment for EMC. It brings together the test conditions, test methods, applicability rules and pass/fail criteria needed to check how DECT products behave under emissions and immunity testing.
The scope is tied to DECT equipment as described in ETS 300 175-2 and I-ETS 300 176, including equipment in residential, commercial, light industrial and vehicular environments. The document notes that the selected levels are intended for normal use environments and may not cover rare extreme cases or strong permanent nearby interference sources.
The standard is organized into:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Definitions
- Clause 4 General test conditions
- Clause 5 Performance assessment
- Clause 6 Performance criteria
- Clause 7 Applicability overview tables
- Clause 8 Test methods and limits for emission tests
- Clause 9 Test methods for immunity tests
What are the key requirements of SIST ETS 300 329 E1:2005?
SIST ETS 300 329 E1:2005 is built around three practical questions: how the equipment is set up, what disturbances are applied, and what still has to work afterwards. The most important requirements are in Clauses 4 to 9.
Clause 4 requires testing under normal operating conditions, within the manufacturer-declared temperature, humidity and supply-voltage range. The setup has to be close to intended use, and the test report must record the conditions and configuration. This matters because EMC results only mean something if the product is tested as users will actually install it.
Clauses 4.2 to 4.7 define the wanted signal, modulation and receiver set-up. DECT equipment is tested with normal test modulation, loop-back data where relevant, and speech arrangements that avoid modifying the equipment just to create a test port. The standard also gives a rule for identifying narrow-band receiver responses so that spurious but harmless responses are not treated as EMC failures.
Clause 5 makes the manufacturer declare the product’s intended functions, the user-control functions and stored data to be protected, the ports, and the ancillary or host equipment used for testing. For host-connected parts, the standard allows either a composite-equipment approach or a test-jig approach with three hosts. This matters because the declared product configuration defines what gets tested and how far a module can be separated from its host.
Clauses 5.5, 5.6 and 6 define the performance criteria. The equipment must keep its primary functions during and after EMC stress, maintain the communications link where applicable, protect user control functions and stored data, and avoid unintentional transmission. Continuous and transient phenomena are handled separately through the CT, TT, CR and TR criteria, so the pass/fail decision matches the type of disturbance.
Clause 6 also covers analogue speech circuits. Where DECT equipment includes speech paths, the speech output level is checked against a reference level during EMC exposure. In practice, this is how the standard judges whether interference is affecting voice quality even when the link still exists.
Clause 8 covers emissions. It uses EN 55022 methods for enclosure radiation and for conducted emissions on DC and AC power ports, with Class B limits. That gives test labs a common method for checking unwanted noise from the enclosure and power connections.
Clause 9 covers immunity. The standard requires tests for radiated RF fields, electrostatic discharge, fast transients, RF common-mode disturbance, vehicular transients and surges, voltage dips and interruptions, and AC mains surges. The exact applicability depends on whether the equipment is base station, mobile, portable or ancillary equipment, and on the type of port being tested.
What terms does SIST ETS 300 329 E1:2005 define?
SIST ETS 300 329 E1:2005 defines the product and test categories that control how EMC testing is applied.
- Ancillary equipment: equipment used with a receiver or transceiver to add control or operating functions, but which cannot provide those functions on its own.
- DECT equipment: apparatus containing one or more DECT transceivers and/or receivers, or parts of them, that conform to ETS 300 175-2.
- Host equipment: equipment with complete user functionality on its own, to which the DECT radio part is added to provide extra functionality.
- Integral antenna: an antenna that is part of the equipment and does not use an external connector.
- Mobile equipment: DECT equipment powered by a vehicular power supply.
- Portable equipment: DECT equipment powered by an internal battery.
- Port: a specific interface between the equipment and the electromagnetic environment.
Who uses SIST ETS 300 329 E1:2005?
SIST ETS 300 329 E1:2005 is used by DECT manufacturers, EMC test laboratories, compliance engineers, quality managers and conformity assessors. It is also relevant to notified bodies and to designers of host equipment or ancillary equipment that must work with a DECT radio part.
In practice, these users apply the standard when they:
- choose the test configuration and declared product class
- prepare the equipment, host and ancillary set-up for testing
- run emission and immunity tests
- document ports, operating modes and test conditions
- evaluate whether communications, user functions and stored data are preserved after EMC stress
Which standards are used with SIST ETS 300 329 E1:2005?
SIST ETS 300 329 E1:2005 relies on several companion standards and references for methods, limits and DECT-specific behavior.
| Standard | What it contributes |
|---|---|
| EN 50081-1 | Generic emission standard for residential, commercial and light industry |
| EN 50082-1 | Generic immunity standard for residential, commercial and light industry |
| prETS 300 339 | General EMC standard for radio equipment |
| 89/336/EEC | EMC Directive referenced for regulatory use |
| ETS 300 175-2 | DECT common interface physical layer and related DECT definitions |
| ETS 300 175-3 | DECT common interface medium access control layer and loop-back behavior |
| I-ETS 300 176 | DECT approval test specification and acoustic test arrangements |
| ISO 7637 Parts 1 and 2 | Vehicular transient disturbance testing on 12 V and 24 V systems |
| EN 55022 | Emission test methods and Class B limits |
| CISPR Publication No. 16-1 | Measuring receiver requirements for conducted emission tests |
| ENV 50140 | Radiated RF immunity test method |
| IEC 801-2 | Electrostatic discharge test method |
| IEC 801-4 | Fast transient test method |
| ENV 50141 | Conducted RF immunity by current clamp injection |
| IEC 1000-4-11 | Voltage dips and interruptions |
| IEC 1000-4-5 | Surge immunity |
What does the SIST ETS 300 329 E1:2005 document contain?
SIST ETS 300 329 E1:2005 contains the test logic, not just a list of limits. Tables 1 and 2 map which emission and immunity tests apply to base station, mobile, portable and ancillary equipment, and Tables 3 to 5 give the emission limits used for enclosure, DC power and AC mains ports.
Clause 5.6 and Figures 1 and 2 set out the audio breakthrough measurement and calibration arrangements for equipment with analogue speech circuits. Clauses 4.7 and 9.2 to 9.8 provide the decision rules, test set-ups and test sequences for receiver responses, RF field immunity, ESD, fast transients, RF common-mode disturbance, vehicular disturbances, voltage dips and surges. The document also tells the assessor what the manufacturer must declare and what the test report must record.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST ETS 300 329 E1:2005 is a standardization document published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio Equipment and Systems (RES); Electro-Magnetic Compatibility (EMC) for Digital European Cordless Telecommunications (DECT) equipment". This standard covers: Covers the EMC requirements for DECT equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
Covers the EMC requirements for DECT equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
SIST ETS 300 329 E1:2005 is classified under the following ICS (International Classification for Standards) categories: 33.060.01 - Radiocommunications in general; 33.070.30 - Digital Enhanced Cordless Telecommunications (DECT); 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ETS 300 329 E1:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Definitions
- 4 General test conditions
- 4.1 Test conditions
- 4.2 Arrangements for test signals at the input of the transceiver
- 4.3 Normal test modulation
- 4.4 Connection of test signals for transceivers
- 4.5 Connection of test signals for receiver-only equipment
- 4.6 Receiver test signal level
- 4.7 Narrow band responses on receivers or receivers which are part of transceivers
- 5 Performance assessment
- 5.1 General
- 5.2 Equipment classification
- 5.3 Ancillary equipment
- 5.4 Assessment of host connected equipment and plug-in cards
- 5.5 Performance assessment test procedure to verify no loss of user control functions or
- 5.6 Performance assessment of audio breakthrough
- 6 Performance criteria
- 6.1 Performance criteria for Continuous phenomena applied to DECT Transceivers (CT)
- 6.2 Performance criteria for Transient phenomena applied to DECT Transceivers (TT)
- 6.3 Performance criteria for Continuous phenomena applied to DECT Receive-only
- 6.4 Performance criteria for Transient phenomena applied to DECT Receive-only equipment
- 7 Applicability overview tables
- 7.1 Emission
- 7.2 Immunity
- 8 Test methods and limits for emission tests of transceivers and/or receivers
- 8.1 Test Configuration
- 8.2 Enclosure
- 8.3 DC power input/output port
- 8.4 AC mains power input/output port
- 9 Test methods for immunity tests of transceivers and/or receivers and/or
- 9.1 Test Configuration
- 9.2 Radio frequency electro-magnetic field (80 - 1 000 MHz)
- 9.3 Electrostatic discharge
- 9.4 Fast transients common mode
- 9.5 RF common mode, 0,15 MHz - 80 MHz (current clamp injection)
- 9.6 Transients and surges, vehicular environment
- 9.7 Voltage dips and interruptions
- 9.8 Surges, common and differential mode
1 Scope
This European Telecommunication Standard (ETS) covers the assessment of radio communication and ancillary equipment in respect of Electro-Magnetic Compatibility (EMC). This ETS specifies the minimum performance and the methods of measurements of EMC on Digital European Cordless Telecommunications (DECT) radio and ancillary equipment. This ETS specifies the applicable EMC tests, the limits, and the performance criteria for digital radio equipment as described in ETS 300 175-2 [5] , and I-ETS 300 176 [6], operating in the frequency range 1 880 to 1 900 MHz, and for the associated ancillary equipment. The environment classification used in this ETS refers to the environment classification used in the Generic Standards EN 50081-1 [1] and EN 50082-1 [2], except the vehicular environment class which refers to ISO 7637 [7].
The EMC requirements have been selected to ensure an adequate level of compatibility for apparatus at residential, commercial, light industrial and vehicular environments. The levels, however, do not cover extreme cases which may occur in any location but with a low probability of occurrence. This ETS may not cover those cases where a potential source of interference, which is producing individually repeated transient phenomena, or a continuous phenomena, is permanently present, e.g. a radar or broadcast site in the near vicinity. In such a case it may be necessary to use special protection applied to either the source of interference, or the interfered part, or both. Compliance of radio equipment to the requirements of this ETS does not signify compliance to any requirement related to the use of the equipment (i.e. licensing requirements). Compliance to this ETS does not signify compliance to any safety requirements. However, it is the responsibility of the assessor of the equipment that any observation regarding the equipment becoming dangerous or unsafe as a result of the application of the tests of this ETS, should be recorded in the test report.
2 Normative references
This ETS incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies.
[1] EN 50081-1 (1992): "Electromagnetic compatibility - Generic emission standard. Part 1: Residential, commercial and light industry".
[2] EN 50082-1 (1992): "Electromagnetic compatibility - Generic immunity standard. Part 1: Residential, commercial and light industry".
[3] Draft prETS 300 339 (1993): "Radio Equipment and Systems (RES) - General Electro-Magnetic Compatibility (EMC) for radio equipment".
[4] 89/336/EEC: "Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility".
[5] ETS 300 175-2 (1993): "Radio Equipment and Systems (RES) - Digital European Cordless Telecommunications (DECT) Common interface Part 2:
Physical layer".
[6] I-ETS 300 176: "Radio Equipment and Systems (RES) - Digital European Cordless Telecommunications (DECT) Approval test specification".
SIST ETS 300 329 E1:2005 Page 8 ETS 300 329: November 1994 [7] ISO 7637 (1990): "Road vehicles-Electrical disturbance by conducting and coupling" Part 1: "Passenger cars and light commercial vehicles with nominal 12 V supply voltage".
ISO 7637 (1990): "Road vehicles-Electrical disturbance by conducting and coupling" Part 2: "Commercial vehicles with nominal 24 V supply voltage- Electrical transient conduction along supply lines only".
[8] ETS 300 175-3: "Radio Equipment and Systems (RES) - Digital European Cordless Telecommunications (DECT) Common interface Part 3: Medium access control layer".
[9] CCITT Recommendation 0.153 (1988): "Basic parameters for the measurement of error performance at bit rates below the primary rates".
[10] EN 55022: "Limits and methods of measurement of radio interference characteristics of information technology equipment".
[11] CISPR Publication No. 16-1: "Specification for radio disturbance and immunity measuring apparatus and methods".
[12] ENV 50140: "Basic immunity standard - Radiated, radio frequency, electromagnetic fields". [13] IEC 801-2 (second edition 1991) Part 2: "Electrostatic discharge requirements". [14] IEC 801-4 (1988) Part 4: "Electrical fast transients / burst requirements". [15] ENV 50141: "Basic immunity standard - Conducted disturbances induced by radio-frequency fields".
[16] IEC 1000-4-11: "Voltage dips, short interruptions and voltage variations. Immunity tests".
[17] IEC 1000-4-5: "Surge immunity requirements".
3 Definitions
For the purposes of this ETS the following definitions apply:
ancillary equipment: Equipment (apparatus), used in connection with a receiver or transceiver is considered as an ancillary equipment (apparatus) if:
- the equipment is intended for use in conjunction with a receiver, or transceiver to provide additional operational and/or control features to the radio equipment (e.g. to extend control to another position or location); and
- the equipment cannot be used on a stand alone basis to provide user functions independently of a receiver or transceiver; and
- the receiver or transceiver to which it is connected, is capable of providing some intended operation such as transmitting and/or receiving without the ancillary equipment (i.e. it is not a sub-unit of the main equipment essential to the main equipment basic functions). base station equipment: Used to describe DECT equipment including Fixed Parts (FPs) and/or Portable Parts (PPs) as defined in ETS 300 175-2 [5] which are powered via an ac power input port or a dc power input port.
DECT equipment: Apparatus which includes one or more transceivers and/or receivers and/or parts thereof which conform to the requirements of ETS 300 175-2 [5].
SIST ETS 300 329 E1:2005 Page 9 ETS 300 329: November 1994 host equipment: Any equipment which has a complete user functionality when not connected to the DECT radio equipment, and to which the DECT radio equipment provides additional functionality, and to which connection is necessary for the DECT radio equipment to offer functionality. integral antenna: An antenna designed to be connected to the equipment without the use of an external connector and considered to be part of the equipment. An integral antenna may be fitted internally or externally to the equipment.
manufacturer: The legal entity responsible under the terms of the Council Directive, 89/336/EEC [4], for placing the product on the market.
mobile equipment: Used to describe all DECT equipment powered by a vehicular power supply. port: A particular interface of the specified equipment (apparatus) with the electro-magnetic environment. portable equipment: Used to describe all DECT equipment powered by an internal battery. NOTE: More than one of the equipment classifications may apply to certain equipment, as described in subclause 5.2, dependent upon the manufacturer's declaration of normal intended use.
4 General test conditions
4.1 Test conditions
The equipment shall be tested under normal test conditions contained in the relevant product and basic standards or in the information accompanying the equipment, which are within the manufacturers declared range of humidity, temperature, and supply voltage.
The test conditions shall be recorded in the test report.
The test configuration shall be as close to normal intended use as possible, and shall be recorded in the test report.
Whenever the EUT is provided with a detachable antenna, the EUT shall be tested with the antenna fitted in a manner typical of normal intended use.
For DECT equipment parts for which connection to a host equipment is necessary to offer functionality the test configuration shall be as defined in subclause 5.4.
4.2 Arrangements for test signals at the input of the transceiver
4.2.1 Loop back data
The normal test modulation shall be transmitted by the test system and looped back in the radio equipment, as described in ETS 300 175-3 [8] and I-ETS 300 176 [6].
4.2.2 Speech equipment
Audio input signals may be connected to the EUT either by a non-metallic acoustic tube or, if provided, electrical connections. The DECT equipment shall not be modified to provide any electrical connection ports for the purposes of this test. Suitable test arrangements for the acoustic tube are described in I-ETS 300 176 [6].
4.3 Normal test modulation
For all types of DECT equipment the wanted input signal shall be a RF carrier set to the nominal centre frequency of one of the DECT RF channels, using gaussian shaped frequency-shift keying (BT = 0,5) and modulated with a 1 152 kbit/s bit sequence.
The encoding of the bit sequence shall conform to the encoding specified in ETS 300 175-2 [5] and ETS 300 175-3 [8].
SIST ETS 300 329 E1:2005 Page 10 ETS 300 329: November 1994 The parts of the data sequence that shall transmit a bit sequence conforming to the D-M2 pattern as specified in CCITT Recommendation 0.153 [9] are those which are looped back according to the loop back test message described in ETS 300 175-3 [8].
The burst timings of this carrier shall conform to the limits specified in ETS 300 175-2 [5].
4.4 Connection of test signals for transceivers
4.4.1 RF connection
Where the equipment incorporates an external antenna connector, the wanted signal to establish communications shall be delivered to that connector by a coaxial cable. Adequate measures shall be taken to minimise the effect of unwanted currents on the external conductor of the coaxial cable at the point of entry to the equipment.
The source of the wanted input signal shall be located outside of the test environment. Where the equipment does not incorporate an external RF connector i.e. integral antenna equipment, the wanted signal to establish communications shall be delivered from the equipment to an antenna located within the test environment. Adequate measures shall be taken to protect the measuring equipment from the effect of all the radiated fields within the test environment.
4.5 Connection of test signals for receiver-only equipment
4.5.1 RF connection
Where the equipment incorporates an external antenna connector, the wanted signal, to establish communications shall be presented to that connector by a coaxial cable. Adequate measures shall be taken to minimise the effect of unwanted currents on the external conductor of the coaxial cable at the point of entry to the equipment.
The source of the wanted input signal shall be located outside of the test environment. Where the equipment does not incorporate an external RF connector i.e. integral antenna equipment, the wanted signal, to establish communications, shall be presented to the equipment from an antenna located within the test environment. Adequate measures shall be taken to protect the measuring equipment from the effect of all the radiated fields within the test environment.
4.6 Receiver test signal level
For tests on receivers and the receiver parts of transceivers the level of the wanted input signal shall be adjusted to approximately 40 dB above the radio receiver sensitivity limit as defined in the ETS 300 175-2 [5].
The source of the wanted input signal shall be located outside of the test environment.
4.7 Narrow band responses on receivers or receivers which are part of transceivers
No immunity tests shall be carried out on frequencies of identified narrow band responses i e. spurious responses, of the receiver parts of the DECT equipment.
The procedure by which a narrow band response is distinguished from a wide band response is as follows:
- if during testing an increase in the bit error rate of the looped back data from the EUT is observed, or there is an increase in the measured value of speech output signal level, the frequency of the unwanted signal shall be recorded and then increased by 2 MHz and the test repeated. Similarly, the frequency of the unwanted signal shall be set to the frequency recorded in the previous test, and then decreased by 2 MHz and the test repeated;
- if the bit error rate and speech output signal of the EUT as measured are within the permitted limits at the two test frequencies described in the previous paragraph, then the response observed at the
SIST ETS 300 329 E1:2005 Page 11 ETS 300 329: November 1994 recorded frequency of the unwanted signal shall be considered a narrow band response and shall not be used in determining the EMC compliance of the EUT; - if the bit error rate or speech output signal level of the EUT as measured is outside the permitted limits at the two test frequencies, then the test shall be repeated using frequency offsets of plus and minus 2,5 MHz. If at this second set of test frequencies the bit error rate or speech output signal level as measured is still outside the permitted limits, then the response is considered to be a wide band phenomena and the EUT fails the test.
5 Performance assessment
5.1 General
The manufacturer shall at the time of submission of the equipment for test, declare the following information which shall be recorded in the test report:
- in the case of receive-only equipment, the primary functions of the radio equipment to be tested during and after the EMC testing;
- the intended functions of the EUT which shall be in accordance with the documentation accompanying the equipment;
- the ancillary equipment and/or host equipment to be used with the radio equipment for testing;
- the user-control functions and stored data that are required for normal operation and the method to be used to assess whether these have been lost after EMC stress;
- an exhaustive list of ports, classified as either power or signal/control. Power ports shall further be classified as ac or dc power.
5.2 Equipment classification
Portable equipment or combinations of equipment declared as capable of being powered for intended use by the battery in the vehicle shall additionally be considered as vehicular mobile equipment. Portable or mobile equipment or combinations of equipment declared as capable of being powered for intended use by ac mains shall additionally be considered as base station equipment.
5.3 Ancillary equipment
At the manufacturer's discretion an ancillary equipment may be:
- declared compliant separately from a receiver or transceiver to all the applicable immunity and emission clauses of this ETS;
- declared compliant to another appropriate harmonized EMC standard;
- tested with it connected to a receiver or transceiver, in which case compliance shall be demonstrated to the appropriate clauses of this ETS.
In each case, compliance enables the ancillary equipment to be used with different receivers, transmitters, or transceivers.
5.4 Assessment of host connected equipment and plug-in cards
For DECT equipment parts for which connection to or integration with a host equipment is necessary in order to offer functionality two alternative approaches are permitted. The manufacturer shall declare which alternative shall be used.
SIST ETS 300 329 E1:2005 Page 12 ETS 300 329: November 1994
5.4.1 Alternative A: composite equipment
A combination of DECT radio equipment part and a specific type of host equipment may be used for assessment according to this ETS.
Where more than one such combination is intended, each combination shall be tested separately. Where a specific combination of host equipment and a DECT radio equipment part is tested as a composite system for compliance, repeat testing shall not be required for:
- those other combinations of hosts and DECT radio equipment parts which are based on substantially similar host models in the circumstance that the variations in mechanical and electrical properties between such host models are unlikely to significantly influence the intrinsic immunity and unwanted emissions of the DECT radio equipment part;
- the DECT radio equipment part which cannot be used without mechanical, electrical, or software modification in variations of host equipment different from those represented by the units for which compliance to this ETS has been demonstrated.
5.4.2 Alternative B: use of a test jig and three hosts
Where the DECT radio equipment part is intended for use with a variety of host equipment, the manufacturer shall supply a suitable test jig to enable compliance with this ETS to be assessed. The test jig shall be designed such that alteration of the DECT radio equipment part's intrinsic immunity and unwanted emissions is minimised.
Where connection between the DECT radio equipment part and the host equipment control and/or power ports is by cables, optical fibres, or other similar means, this connection to the host shall be considered as a suitable test jig.
The test jig shall allow the DECT radio equipment part to be powered and stimulated in a way similar to the way in which it would be powered and stimulated when connected to or inserted into the host equipment.
In addition to tests using the test jig the DECT radio equipment part shall be tested when connected to, or inserted into, three different host equipment. These hosts shall be provided by the manufacturer and shall be selected from the list of compatible hosts published by the manufacturer as part of the user documentation supplied with the DECT radio equipment part.
The selection of hosts shall be by agreement with the Notified Body. Notified bodies shall have the discretion to require the manufacturer to inform them of each deletion from or addition to the list of compatible hosts published in the user documentation.
5.5 Performance assessment test procedure to verify no loss of user control functions or
stored data for DECT transceivers The test system shall send the test message "clear test modes" as described in ETS 300 175-3 [8] if the bearer was maintained.
The test system shall control the EUT so that it transmits on a specified slot and channel according to the test procedures described in ETS 300 175-3 [8].
The test system shall verify a Bit Error Ratio (BER) of 1x10 or better.
...