Abstract

Covers the EMC requirements for DECT equipment. This amendment makes the neseccary modifications to bring ETS 300 329 into line with the policy described in ETR 238. This ETS is intended to become a Harmonised Standard, the reference of which is intended to be published in the Official Journal of the European Communities referencing the EMC Directive.

Status
Published
Publication Date
30-Sep-1998
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Oct-1998
Due Date
01-Oct-1998
Completion Date
01-Oct-1998
Mandate
T-353

Buy Documents

Standardization document

SIST ETS 300 329:1998

English language (29 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 329:1998 is the Slovenian adoption of ETS 300 329 Edition 2 from ETSI. It specifies electromagnetic compatibility (EMC) requirements, test methods, limits and performance criteria for Digital Enhanced Cordless Telecommunications (DECT) radio equipment and associated ancillary equipment, so manufacturers and test laboratories can assess how the equipment behaves under EMC stress.

What does SIST ETS 300 329:1998 specify?

SIST ETS 300 329:1998 covers the EMC assessment of DECT radio communication and ancillary equipment operating in the 1 880 to 1 900 MHz range. It sets the minimum performance, measurement methods, test limits and pass criteria for the radio equipment types described in ETS 300 175-2 and I-ETS 300 176.

The standard uses the environment classes from the generic EMC standards for residential, commercial, light industrial and vehicular use. It also makes clear that compliance with this ETS is not the same as compliance with licensing or safety requirements.

The document is organized into a foreword, clauses 1 to 9, and Annex A. Clause 1 gives the scope, clause 2 lists normative references, clauses 3 to 6 define the terminology, test conditions, performance assessment and performance criteria, clause 7 gives applicability tables, and clauses 8 and 9 give the emission and immunity test methods.

AnnexWhat it covers
Annex ASubclauses relevant for compliance with the essential requirements of the EC Council Directives, mapped to the EMC Directive

What are the key requirements of SIST ETS 300 329:1998?

Test setup and signal conditions

SIST ETS 300 329:1998 requires testing under normal conditions from the relevant product or basic standards, or from the equipment documentation, within the manufacturer’s declared humidity, temperature and supply-voltage range. The test configuration must be as close as practical to intended use, and detachable antennas must be fitted in a typical way.

For transceivers, the normal test modulation uses the DECT RF carrier at the nominal channel centre frequency with gaussian shaped frequency-shift keying and a 1 152 kbit/s bit sequence. For speech equipment, the audio input may be coupled acoustically or electrically, but the equipment must not be modified just to add test ports.

For receivers and receiver parts of transceivers, the wanted input signal is set well above sensitivity, and the standard includes a method for ignoring narrow band responses. In practice, this means labs must distinguish genuine EMC problems from spurious receiver responses before judging failure.

Performance assessment and host equipment

SIST ETS 300 329:1998 requires the manufacturer to declare, at submission for test, the primary functions to be checked, the intended functions, the ancillary or host equipment to be used, the ports, and the method for checking loss of user control functions or stored data. That declaration is recorded in the test report, so the test lab knows exactly what has been evaluated.

The standard classifies equipment as base station equipment, mobile equipment or portable equipment, and some products may fit more than one class depending on intended use. This matters because the applicable emission and immunity tests depend on the class.

For DECT equipment that needs host equipment to function, two assessment routes are allowed. One route tests a specific composite system with the intended host, and the other uses a test jig plus three host equipment examples selected with agreement from the Notified Body. This helps manufacturers of plug-in cards and embedded radio parts show representative EMC performance without testing every possible host.

Emission requirements

Clause 8 covers emission testing for transceivers, receivers and ancillary equipment. It includes enclosure radiation testing for ancillary equipment, conducted emission testing on DC power ports, and conducted emission testing on AC mains ports where applicable.

The test configuration must represent normal operation, use enough connected ports to simulate real use, and maximize emissions where practical. The methods reference EN 55022 and CISPR 16-1, and the limits are taken from the class B framework used in the standard. In practice, the lab needs to measure both what the equipment radiates and what it puts onto its power leads.

Immunity requirements

Clause 9 covers immunity tests for radio frequency fields, electrostatic discharge, fast transients, conducted RF disturbance, vehicular transients and surges, voltage dips and interruptions, and AC mains surges. Applicability depends on whether the equipment is base station, mobile, portable or ancillary equipment.

The test methods reference EN 61000-4-2, -4-3, -4-4, -4-5, -4-6 and -4-11, plus ISO 7637-1 and ISO 7637-2 for vehicular power-line disturbances. The standard also tells the tester when to ignore narrow band receiver responses and when to record the exact frequencies used.

Performance criteria during and after stress

SIST ETS 300 329:1998 uses four performance criterion groups: CT and TT for DECT transceivers, and CR and TR for DECT receive-only equipment. Continuous-phenomena tests focus on maintaining the link and avoiding loss of user control functions or stored data, while transient-phenomena tests check that the equipment returns to intended operation after each exposure.

For equipment with analogue speech circuits, the standard also checks audio breakthrough by measuring the speech output response during EMC stress. In practical terms, the equipment must keep its communications function, and any speech degradation must remain within the allowed criterion.

What terms does SIST ETS 300 329:1998 define?

  • Ancillary equipment - Equipment used with a receiver or transceiver to add operational or control functions, but which cannot work as a stand-alone user device.
  • DECT equipment - Apparatus that includes one or more transceivers or receivers, or parts of them, that conform to ETS 300 175-2.
  • Host equipment - Equipment that can work on its own, but to which DECT radio equipment must be connected to provide extra functionality.
  • Base station equipment - DECT equipment powered from AC mains or DC power input, including Fixed Parts (FP) and Portable Parts (PP) in this standard’s usage.
  • Mobile equipment - DECT equipment powered by a vehicular supply.
  • Portable equipment - DECT equipment powered by an internal battery.
  • Equipment Under Test (EUT) - The specific equipment being subjected to the EMC test sequence.

Who uses SIST ETS 300 329:1998?

Manufacturers of DECT radios, cordless telephony products and DECT ancillary equipment use this standard to design products for EMC testing and to prepare the required declarations for the test lab. Test laboratories use it to set up measurements, choose the right configurations and apply the correct performance criteria.

Notified Bodies and EMC compliance engineers use it when reviewing host-connected equipment, plug-in cards and product-family claims. Buyers and quality managers use it to understand whether a DECT product has been assessed for the EMC environment they need, especially in residential, commercial, light industrial or vehicular use.

What changed in SIST ETS 300 329:1998 from the previous edition?

SIST ETS 300 329:1998 is the second edition of ETS 300 329. The scope and foreword state that this edition makes the changes needed to align the standard with the policy described in ETR 238 and to support publication as a Harmonised Standard for the EMC Directive.

Which standards are used with SIST ETS 300 329:1998?

  • EN 50081-1 and EN 50082-1 - Provide the generic emission and immunity environment classification used by the standard.
  • 89/336/EEC - The EMC Directive context for the harmonized compliance mapping in Annex A.
  • ETS 300 175-2 and ETS 300 175-3 - Define the DECT physical layer and MAC-layer behavior used in test signaling and loopback procedures.
  • I-ETS 300 176 - Gives the DECT approval test specification and acoustic test arrangements.
  • ISO 7637-1 and ISO 7637-2 - Provide the vehicular transient test framework for 12 V and 24 V DC systems.
  • EN 55022 and CISPR 16-1 - Supply the conducted and radiated emission measurement methods and limits framework.
  • EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 - Provide the EMC immunity test methods for ESD, radiated RF, fast transients, surges, conducted RF and voltage dips/interruptions.
  • ITU-T Recommendation 0.153 - Provides the bit-pattern reference used in the DECT loopback test sequence.
  • ETR 238 - The policy guidance named in the foreword and scope as the basis for the amendments.

What does the SIST ETS 300 329:1998 document contain?

The document contains the full EMC test framework for DECT equipment, including the general test conditions in clause 4, the performance assessment rules in clause 5, and the performance criteria in clause 6. It also includes applicability overview tables that show which tests apply to base station, mobile, portable and ancillary equipment.

Clauses 8 and 9 give the emission and immunity test methods, while Annex A maps the relevant subclauses to the essential requirements of the EC Council Directive. The document also includes two figures for the audio breakthrough measurement setup and calibration, which are used when analogue speech circuits must be assessed during EMC testing.

Buy Documents

Standardization document

SIST ETS 300 329:1998

English language (29 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 329:1998 is a standardization document published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) for Digital Enhanced Cordless Telecommunications (DECT) equipment". This standard covers: Covers the EMC requirements for DECT equipment. This amendment makes the neseccary modifications to bring ETS 300 329 into line with the policy described in ETR 238. This ETS is intended to become a Harmonised Standard, the reference of which is intended to be published in the Official Journal of the European Communities referencing the EMC Directive.

Covers the EMC requirements for DECT equipment. This amendment makes the neseccary modifications to bring ETS 300 329 into line with the policy described in ETR 238. This ETS is intended to become a Harmonised Standard, the reference of which is intended to be published in the Official Journal of the European Communities referencing the EMC Directive.

SIST ETS 300 329:1998 is classified under the following ICS (International Classification for Standards) categories: 33.060.01 - Radiocommunications in general; 33.070.30 - Digital Enhanced Cordless Telecommunications (DECT); 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 329:1998 is associated with the following European legislation: Standardization Mandates: T-353. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST ETS 300 329:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Definitions and abbreviations
  • 3.1 Definitions
  • 3.2 Abbreviations
  • 4 General test conditions
  • 4.1 Test conditions
  • 4.2 Arrangements for test signals at the input of the transceiver
  • 4.3 Normal test modulation
  • 4.4 Connection of test signals for transceivers
  • 4.5 Connection of test signals for receiver-only equipment
  • 4.6 Receiver test signal level
  • 4.7 Narrow band responses on receivers or receivers which are part of transceivers
  • 5 Performance assessment
  • 5.1 General
  • 5.2 Equipment classification
  • 5.3 Ancillary equipment
  • 5.4 Assessment of host connected equipment and plug-in cards
  • 5.5 Performance assessment test procedure to verify no loss of user control functions or
  • 5.6 Performance assessment of audio breakthrough
  • 6 Performance criteria
  • 6.1 Performance criteria for Continuous phenomena applied to DECT Transceivers (CT)
  • 6.2 Performance criteria for Transient phenomena applied to DECT Transceivers (TT)
  • 6.3 Performance criteria for Continuous phenomena applied to DECT Receive-only
  • 6.4 Performance criteria for Transient phenomena applied to DECT Receive-only
  • 7 Applicability overview tables
  • 7.1 Emission
  • 7.2 Immunity
  • 8 Test methods and limits for emission tests of transceivers and/or receivers
  • 8.1 Test configuration
  • 8.2 Enclosure, ancillary equipment tested in isolation
  • 8.3 DC power input/output port
  • 8.4 AC mains power input/output port
  • 9 Test methods for immunity tests of transceivers and/or receivers and/or
  • 9.1 Test configuration
  • 9.2 Radio frequency electromagnetic field (80 - 1 000 MHz)
  • 9.3 Electrostatic discharge
  • 9.4 Fast transients common mode
  • 9.5 RF common mode, 0,15 MHz - 80 MHz
  • 9.6 Transients and surges, vehicular environment
  • 9.7 Voltage dips and interruptions
  • 9.8 Surges, common and differential mode
  • Annex A (normative): Subclauses of this ETS relevant for compliance with
  • 8 Test methods and limits for emission
  • 8.2 Enclosure, ancillary equipment tested 4(a)
  • 8.3 DC power input/output port 4(a)
  • 8.4 AC mains 4(a)
  • 9 Test methods for immunity tests of
  • 9.2 Radio frequency electromagnetic field 4(b)
  • 9.3 Electrostatic discharge 4(b)
  • 9.4 Fast transient common mode 4(b)
  • 9.5 RF common mode, 0,15 - 80 MHz 4(b)
  • 9.6 Transient and surges, vehicular 4(b)
  • 9.7 Voltage dips and interruptions 4(b)
  • 9.8 Surges, common and differential 4(b)

1 Scope

This European Telecommunication Standard (ETS) covers the assessment of radio communication and ancillary equipment in respect of ElectroMagnetic Compatibility (EMC). This ETS specifies the minimum performance and the methods of measurements of EMC on Digital Enhanced Cordless Telecommunications (DECT) radio and ancillary equipment. This ETS specifies the applicable EMC tests, the limits, and the performance criteria for digital radio equipment as described in ETS 300 175-2 [4] and I-ETS 300 176 [5], operating in the frequency range 1 880 to 1 900 MHz, and for the associated ancillary equipment. The environment classification used in this ETS refers to the environment classification used in the Generic Standards EN 50081-1 [1] and EN 50082-1 [2], except the vehicular environment class which refers to ISO 7637 [6], [7].

The EMC requirements have been selected to ensure an adequate level of compatibility for apparatus at residential, commercial, light industrial and vehicular environments. The levels, however, do not cover extreme cases which may occur in any location but with a low probability of occurrence. This ETS may not cover those cases where a potential source of interference, which is producing individually repeated transient phenomena, or a continuous phenomena, is permanently present, e.g. a radar or broadcast site in the near vicinity. In such a case it may be necessary to use special protection applied to either the source of interference, or the interfered part, or both. Compliance of radio equipment to the requirements of this ETS does not signify compliance to any requirement related to the use of the equipment (i.e. licensing requirements). Compliance to this ETS does not signify compliance to any safety requirements. However, it is the responsibility of the assessor of the equipment that any observation regarding the equipment becoming dangerous or unsafe as a result of the application of the tests of this ETS, should be recorded in the test report.

2 Normative references

This ETS incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies.

[1] EN 50081-1 (1992): "Electromagnetic compatibility - Generic emission standard. Part 1: Residential, commercial and light industry".

[2] EN 50082-1 (1992): "Electromagnetic compatibility - Generic immunity standard. Part 1: Residential, commercial and light industry".

[3] 89/336/EEC: "Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility".

[4] ETS 300 175-2 (1993): "Radio Equipment and Systems (RES) - Digital European Cordless Telecommunications (DECT) Common interface Part 2:

Physical layer".

[5] I-ETS 300 176: "Radio Equipment and Systems (RES) - Digital European Cordless Telecommunications (DECT) Approval test specification". [6] ISO 7637-1 (1990): "Road vehicles - Electrical disturbance by conduction and coupling - Part 1: Passenger cars and light commercial vehicles with nominal 12 V supply voltage - Electrical transient conduction along supply lines only".

SIST ETS 300 329:1998 Page 8 ETS 300 329: June 1997 [7] ISO 7637-2 (1990): "Road vehicles - Electrical disturbance by conduction and coupling - Part 2: Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines only".

[8] ETS 300 175-3: "Radio Equipment and Systems (RES); Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 3: Medium Access Control (MAC) layer".

[9] ITU-T Recommendation 0.153 (1988): "Basic parameters for the measurement of error performance at bit rates below the primary rate".

[10] EN 55022 (1994): "Limits and methods of measurement of radio disturbance characteristics of information technology equipment".

[11] CISPR 16-1 (1993): "Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus".

[12] EN 61000-4-3: "Electromagnetic Compatibility (EMC) - Part 4: Testing and measurements techniques - Section 3: Radiated, radio-frequency, electromagnetic field immunity test".

[13] EN 61000-4-2: "Electromagnetic Compatibility (EMC) - Part 4: Testing and measurements techniques - Section 2: Electrostatic discharge immunity test. Basic EMC publication".

[14] EN 61000-4-4: "Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 4: Electrical fast transient/burst immunity test. Basic EMC publication".

[15] EN 61000-4-6: "Electromagnetic Compatibility (EMC) - Part 4: Testing and measurements techniques - Section 6: Immunity to conducted disturbances induced by radio-frequency fields".

[16] EN 61000-4-11: "Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 11: Voltage dips, short interruptions and voltage variations immunity tests".

[17] EN 61000-4-5: "Electromagnetic Compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test".

3 Definitions and abbreviations

3.1 Definitions

For the purposes of this ETS, the following definitions apply:

ancillary equipment: Equipment (apparatus), used in connection with a receiver or transceiver is considered as an ancillary equipment (apparatus) if:

  • the equipment is intended for use in conjunction with a receiver, or transceiver to provide additional operational and/or control features to the radio equipment (e.g. to extend control to another position or location); and
  • the equipment cannot be used on a stand alone basis to provide user functions independently of a receiver or transceiver; and
  • the receiver or transceiver to which it is connected, is capable of providing some intended operation such as transmitting and/or receiving without the ancillary equipment (i.e. it is not a sub-unit of the main equipment essential to the main equipment basic functions).

SIST ETS 300 329:1998 Page 9 ETS 300 329: June 1997 base station equipment: Used to describe DECT equipment including Fixed Parts (FP) and/or Portable Parts (PP) as defined in ETS 300 175-2 [4] which are powered via an AC power input port or a DC power input port.

DECT equipment: Apparatus which includes one or more transceivers and/or receivers and/or parts thereof which conform to the requirements of ETS 300 175-2 [4]. host equipment: Any equipment which has a complete user functionality when not connected to the DECT radio equipment, and to which the DECT radio equipment provides additional functionality, and to which connection is necessary for the DECT radio equipment to offer functionality. integral antenna: An antenna designed to be connected to the equipment without the use of an external connector and considered to be part of the equipment. An integral antenna may be fitted internally or externally to the equipment.

manufacturer: The legal entity responsible under the terms of the Council Directive 89/336/EEC [3] for placing the product on the market.

mobile equipment: DECT equipment powered by a vehicular power supply. port: A particular interface of the specified equipment (apparatus) with the electro-magnetic environment. portable equipment: DECT equipment powered by an internal battery. NOTE: More than one of the equipment classifications may apply to certain equipment, as described in subclause 5.2, dependent upon the manufacturer's declaration of normal intended use.

3.2 Abbreviations

For the purposes of this ETS, the following abbreviations apply:

BER Bit Error Ratio BPF Band Pass Filter BW Band Width CF Carrier Frequency BER Bit Error Ratio CR Continuous phenomena applied to DECT Receive-only equipment CT Continuous phenomena applied to DECT Transceivers DECT Digital Enhanced Cordless Telecommunications EMC ElectroMagnetic Compatibility ERP Ear Reference Point EUT Equipment Under Test FP Fixed Part LISN Line Impedance Stabilization Network MRP Mouth Reference Point PP Portable Part RF Radio Frequency SPL Sound Pressure Level TR Transient phenomena applied to DECT Receive-only equipment TT Transient phenomena applied to DECT Transceivers

4 General test conditions

4.1 Test conditions

The equipment shall be tested under normal test conditions contained in the relevant product and basic standards or in the information accompanying the equipment, which are within the manufacturer's declared range of humidity, temperature, and supply voltage.

The test conditions shall be recorded in the test report.

SIST ETS 300 329:1998 Page 10 ETS 300 329: June 1997 The test configuration shall be as close to normal intended use as possible, and shall be recorded in the test report.

Whenever the Equipment Under Test (EUT) is provided with a detachable antenna, the EUT shall be tested with the antenna fitted in a manner typical of normal intended use. For DECT equipment parts for which connection to a host equipment is necessary to offer functionality the test configuration shall be as defined in subclause 5.4.

4.2 Arrangements for test signals at the input of the transceiver

4.2.1 Loop back data

The normal test modulation shall be transmitted by the test system and looped back in the radio equipment, as described in ETS 300 175-3 [8] and I-ETS 300 176 [5].

4.2.2 Speech equipment

Audio input signals may be connected to the EUT either by a non-metallic acoustic tube or, if provided, electrical connections. The DECT equipment shall not be modified to provide any electrical connection ports for the purposes of this test. Suitable test arrangements for the acoustic tube are described in I-ETS 300 176 [5].

4.3 Normal test modulation

For all types of DECT equipment the wanted input signal shall be a Radio Frequency (RF) carrier set to the nominal centre frequency of one of the DECT RF channels, using gaussian shaped frequency-shift keying (BT = 0,5) and modulated with a 1 152 kbit/s bit sequence. The encoding of the bit sequence shall conform to the encoding specified in ETS 300 175-2 [4] and ETS 300 175-3 [8].

The parts of the data sequence that shall transmit a bit sequence conforming to the D-M2 pattern as specified in ITU-T Recommendation 0.153 [9] are those which are looped back according to the loop back test message described in ETS 300 175-3 [8].

The burst timings of this carrier shall conform to the limits specified in ETS 300 175-2 [4].

4.4 Connection of test signals for transceivers

4.4.1 RF connection

Where the equipment incorporates an external antenna connector, the wanted signal to establish communications shall be delivered to that connector by a coaxial cable. Adequate measures shall be taken to minimize the effect of unwanted currents on the external conductor of the coaxial cable at the point of entry to the equipment.

The source of the wanted input signal shall be located outside of the test environment. Where the equipment does not incorporate an external RF connector i.e. integral antenna equipment, the wanted signal to establish communications shall be delivered from the equipment to an antenna located within the test environment. Adequate measures shall be taken to protect the measuring equipment from the effect of all the radiated fields within the test environment.

4.5 Connection of test signals for receiver-only equipment

4.5.1 RF connection

Where the equipment incorporates an external antenna connector, the wanted signal to establish communications shall be presented to that connector by a coaxial cable. Adequate measures shall be taken to minimize the effect of unwanted currents on the external conductor of the coaxial cable at the point of entry to the equipment.

SIST ETS 300 329:1998 Page 11 ETS 300 329: June 1997 The source of the wanted input signal shall be located outside of the test environment. Where the equipment does not incorporate an external RF connector i.e. integral antenna equipment, the wanted signal, to establish communications, shall be presented to the equipment from an antenna located within the test environment. Adequate measures shall be taken to protect the measuring equipment from the effect of all the radiated fields within the test environment.

4.6 Receiver test signal level

For tests on receivers and the receiver parts of transceivers the level of the wanted input signal shall be adjusted to approximately 40 dB above the radio receiver sensitivity limit as defined in ETS 300 175-2 [4]. The source of the wanted input signal shall be located outside of the test environment.

4.7 Narrow band responses on receivers or receivers which are part of transceivers

No immunity tests shall be carried out on frequencies of identified narrow band responses i. e. spurious responses, of the receiver parts of the DECT equipment.

The procedure by which a narrow band response is distinguished from a wide band response is as follows:

  • if during testing an increase in the bit error rate of the looped back data from the EUT is observed, or there is an increase in the measured value of speech output signal level, the frequency of the unwanted signal shall be recorded and then increased by 2 MHz and the test repeated. Similarly, the frequency of the unwanted signal shall be set to the frequency recorded in the previous test, and then decreased by 2 MHz and the test repeated;
  • if the bit error rate and speech output signal of the EUT as measured are within the permitted limits at the two test frequencies described in the previous paragraph, then the response observed at the recorded frequency of the unwanted signal shall be considered a narrow band response and shall not be used in determining the EMC compliance of the EUT;
  • if the bit error rate or speech output signal level of the EUT as measured is outside the permitted limits at the two test frequencies, then the test shall be repeated using frequency offsets of plus and minus 2,5 MHz. If at this second set of test frequencies the bit error rate or speech output signal level as measured is still outside the permitted limits, then the response is considered to be a wide band phenomena and the EUT fails the test.

5 Performance assessment

5.1 General

The manufacturer shall at the time of submission of the equipment for test, declare the following information which shall be recorded in the test report:

  • in the case of receive-only equipment, the primary functions of the radio equipment to be tested during and after the EMC testing;
  • the intended functions of the EUT which shall be in accordance with the documentation accompanying the equipment;
  • the ancillary equipment and/or host equipment to be used with the radio equipment for testing;
  • the user-control functions and stored data that are required for normal operation and the method to be used to assess whether these have been lost after EMC stress;
  • an exhaustive list of ports, classified as either power or signal/control. Power ports shall further be classified as AC or DC power;
  • the volume setting required to provide nominal operation of the product as defined in I-ETS 300 176 [5].

SIST ETS 300 329:1998 Page 12 ETS 300 329: June 1997

5.2 Equipment classification

Portable equipment or combinations of equipment declared as capable of being powered for intended use by the battery in the vehicle shall additionally be considered as vehicular mobile equipment. Portable or mobile equipment or combinations of equipment declared as capable of being powered for intended use by AC mains shall additionally be considered as base station equipment.

5.3 Ancillary equipment

At the manufacturer's discretion an ancillary equipment may be:

  • declared compliant separately from a receiver or transceiver to all the applicable immunity and emission clauses of this ETS;
  • declared compliant to another appropriate harmonized EMC standard;
  • tested with it connected to a receiver or transceiver, in which case compliance shall be demonstrated to the appropriate clauses of this ETS.

In each case, compliance enables the ancillary equipment to be used with different receivers, transmitters, or transceivers.

5.4 Assessment of host connected equipment and plug-in cards

For DECT equipment parts for which connection to or integration with a host equipment is necessary in order to offer functionality, two alternative approaches defined in subclauses 5.4.1 and 5.4.2 may be used. The manufacturer shall declare which alternative is to be used.

5.4.1 Alternative A: composite equipment

A combination of DECT radio equipment part and a specific type of host equipment may be used for assessment according to this ETS.

Where more than one such combination is intended, each combination shall be tested separately. Where a specific combination of host equipment and a DECT radio equipment part is tested as a composite system for compliance, repeat testing shall not be required for:

  • those other combinations of hosts and DECT radio equipment parts which are based on substantially similar host models in the circumstance that the variations in mechanical and electrical properties between such host models are unlikely to influence significantly the intrinsic immunity and unwanted emissions of the DECT radio equipment part;
  • the DECT radio equipment part which can not be used without mechanical, electrical, or software modification in variations of host equipment different from those represented by the units for which compliance to this ETS has been demonstrated.
5.4.2 Alternative B: use of a test jig and three hosts

Where the DECT radio equipment part is intended for use with a variety of host equipment, the manufacturer shall supply a suitable test jig to enable compliance with this ETS to be assessed. The test jig shall be designed such that alteration of the DECT radio equipment part's intrinsic immunity and unwanted emissions is minimized.

Where connection between the DECT radio equipment part and the host equipment control and/or power ports is by cables, optical fibres, or other similar means, this connection to the host shall be considered as a suitable test jig.

SIST ETS 300 329:1998 Page 13 ETS 300 329: June 1997 The test jig shall allow the DECT radio equipment part to be powered and stimulated in a way similar to the way in which it would be powered and stimulated when connected to or inserted into the host equipment.

In addition to tests using the test jig the DECT radio equipment part shall be tested when connected to, or inserted into, three different host equipment. These hosts shall be provided by the manufacturer and shall be selected from the list of compatible hosts published by the manufacturer as part of the user documentation supplied with the DECT radio equipment part.

The selection of hosts shall be by agreement with the Notified Body. Notified bodies have the discretion to require the manufacturer to inform them of each deletion from or addition to the list of compatible hosts published in the user documentation.

...