SIST EN 300 225 V1.4.1:2006
(Main)Electromagnetic compatibility and Radio spectrum Matters (ERM); Technical characteristics and methods of measurement for survival craft portable VHF radiotelephone apparatus
- Abstract
The present document states the minimum technical characteristics required for portable VHF radiotelephones operating in the bands between 156 MHz and 174 MHz allocated to the Maritime Mobile Services by the Radio Regulations (see Radio Regulations, Appendices 18 [1] and 19 [2]) and suitable for use in survival craft and, optionally, on board ships at sea. The requirements detailed in the Radio Regulations, International Convention for the Safety Of Life At Sea SOLAS 1974 and the International Maritime Organization Resolutions A.694(17) [4] and A.809(19) [3] are incorporated in the present document.
- Status
- Published
- Publication Date
- 28-Feb-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Mar-2006
- Due Date
- 01-Mar-2006
- Completion Date
- 01-Mar-2006
SIST EN 300 225 V1.4.1:2006 is the Slovenian adoption of ETSI EN 300 225 V1.4.1 for portable VHF radiotelephone apparatus used in survival craft. It specifies the minimum technical characteristics and measurement methods for equipment operating in the 156 MHz to 174 MHz Maritime Mobile Service bands, so manufacturers, test laboratories and buyers can check whether a handset is suitable for maritime distress and safety use.
What does SIST EN 300 225 V1.4.1:2006 specify?
SIST EN 300 225 V1.4.1:2006 specifies portable VHF radiotelephones for survival craft and, optionally, for use on board ships at sea. It sets out minimum technical characteristics and the measurement methods used to verify them, and it brings in requirements from the Radio Regulations, SOLAS 1974, and IMO Resolutions A.694(17) and A.809(19).
The document is organized into general requirements, test conditions, measurement methods, environmental tests, field measurements, transmitter and receiver tests, and secondary battery charger requirements. Two normative annexes cover the special measuring receiver used for adjacent channel power measurements and the solar radiation test source.
| Annex | What it covers |
|---|---|
| Annex A | Measuring receiver specification for adjacent channel power measurement |
| Annex B | Simulated solar radiation source for the solar radiation test |
What are the key requirements of SIST EN 300 225 V1.4.1:2006?
SIST EN 300 225 V1.4.1:2006 focuses on three things in practice: the radio must work for emergency maritime use, it must survive harsh marine conditions, and it must be testable in a repeatable way. The clauses give the product features, the operating conditions and the acceptance limits that a test house checks.
Portable construction and use in survival craft - Clause 4.1 requires a portable set with an integral transmitter/receiver, antenna, battery, control unit, microphone and loudspeaker. It must be easy to use with gloves, operable largely with one hand, small and light, highly visible, and fitted for attachment to clothing plus a wrist or neck strap. In practice, this means the radio must be usable during an evacuation or rescue, not just on a bench.
Channel and frequency behavior - Clause 4.2 requires simplex operation on single-frequency channels, with channel 16 and at least one other channel from Appendix 18, excluding DSC calling channel 70. Independent transmit and receive frequency selection is not allowed. Clause 4.4 limits channel switching to 5 seconds and transmit-receive changeover to 0,3 seconds, so the set can be used quickly under stress.
Emission and modulation - Clause 4.6 specifies phase modulation, G3E, with 25 kHz channel separation and frequency deviation approaching ±5 kHz. Clauses 9.4 to 9.11 then check deviation, audio response, distortion, adjacent channel power, residual modulation and transient frequency behavior. In practice, these tests confirm that speech is intelligible and that the radio does not interfere excessively with nearby channels.
Power and battery endurance - Clause 4.7 requires an integral battery, operation from primary batteries, and at least eight hours of continuous operation using the stated transmit-to-receive duty cycle at the highest rated transmit power. It also requires easy battery replacement without special tools and without harming watertightness. Clause 11 adds requirements for a secondary battery charger, including charge indication, full-charge indication, and charging time of no more than 14 hours.
Environmental resistance - Clause 7 subjects the equipment to drop, vibration, temperature cycling, sea-water corrosion, immersion, thermal shock, solar radiation and oil resistance tests. The practical point is that the radio must still pass a performance check after exposure to the kind of handling and weather a survival craft set can face at sea.
Receiver performance - Clause 10 checks receiver sensitivity, selectivity, blocking, intermodulation response, limiter behavior and receiver noise. For users, this means weak distress calls should still be received while strong nearby signals, interference and noise are controlled.
Field emissions and transmitter power - Clauses 8.2 to 8.4 measure transmitter ERP and spurious emissions from both transmitter and receiver. The limits control unwanted radiation, which matters for spectrum use and for avoiding interference with other maritime and nearby radio services.
Test conditions and uncertainty - Clauses 5 and 6 define normal and extreme test temperatures, humidity, power sources, receiver input arrangements, normal test modulation and measurement uncertainty. Clause 6.7 requires measurement uncertainty to be reported and used in deciding conformance. For a buyer or test lab, this is what makes results comparable and auditable.
What terms does SIST EN 300 225 V1.4.1:2006 define?
- ERP (Effective Radiated Power) - The power radiated in the direction of maximum field strength, used to judge how strongly the transmitter can be heard.
- SINAD - The ratio of signal plus noise plus distortion to noise plus distortion, used to assess receiver quality under realistic speech conditions.
- MMS (Maritime Mobile Service) - The maritime radio service for ship and shore communications in the frequency bands covered by the standard.
- DSC (Digital Selective Calling) - A maritime calling method mentioned because channel 70 is excluded from the operating channels in this document.
- emf (electro-motive force) - The signal level expressed at the receiver input terminals during sensitivity and rejection tests.
- IF (Intermediate Frequency) - The internal receiver frequency used in the measuring receiver described in Annex A.
Who uses SIST EN 300 225 V1.4.1:2006?
SIST EN 300 225 V1.4.1:2006 is used by manufacturers of survival craft VHF radiotelephones and by makers of associated battery chargers. It is also used by test houses, conformity assessment bodies, and technical teams that perform type testing, production verification or certification of maritime radio equipment.
Ship equipment buyers, quality managers and regulators use it to compare products against the same technical target. It is especially relevant in maritime safety, GMDSS-related equipment supply, and the design or procurement of radios intended for life-saving appliances.
What changed in SIST EN 300 225 V1.4.1:2006 from the previous edition?
SIST EN 300 225 V1.4.1:2006 is the result of incorporating an amendment into the third edition of ETS 300 225 (1998). The foreword states that this amendment was approved through the ETSI One-step Approval Procedure.
Which standards are used with SIST EN 300 225 V1.4.1:2006?
- ITU Radio Regulations, Appendix 18 - Gives the VHF maritime mobile transmitting frequencies used by this standard.
- ITU Radio Regulations, Appendix 19 - Provides related maritime technical characteristics referenced in the scope.
- IMO Resolution A.809(19) - Gives performance standards for survival craft two way VHF radiotelephone apparatus.
- IMO Resolution A.694(17) - Sets general requirements for shipborne radio equipment forming part of GMDSS and for electronic navigational aids.
- ETSI TR 100 028 - Provides the method used to treat measurement uncertainty.
- ITU-T Recommendation O.41 - Describes the psophometer network used for SINAD measurements.
- ETSI EN 300 019 - Gives environmental conditions and environmental test classifications for telecommunications equipment.
- ISO 694 - Is used for the compass safe distance declaration.
- SOLAS 1974 - Supplies the maritime safety framework incorporated into the equipment requirements.
What does the SIST EN 300 225 V1.4.1:2006 document contain?
The document contains detailed test procedures for construction checks, channel switching, power limits, modulation quality, transmitter transient behavior, receiver sensitivity and interference rejection. It also includes environmental test methods such as drop, vibration, salt mist, immersion, thermal shock, solar radiation and oil exposure, plus separate procedures for the secondary battery charger.
Several clauses define how to set up the tests, including the use of artificial antennas, combining networks, measuring receivers, substitution methods and performance checks before and after environmental exposure. Annex A gives the characteristics of the receiver used for adjacent channel power measurement, and Annex B defines the simulated solar radiation source used in the sunlight test.
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
SIST EN 300 225 V1.4.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM); Technical characteristics and methods of measurement for survival craft portable VHF radiotelephone apparatus". This standard covers: The present document states the minimum technical characteristics required for portable VHF radiotelephones operating in the bands between 156 MHz and 174 MHz allocated to the Maritime Mobile Services by the Radio Regulations (see Radio Regulations, Appendices 18 [1] and 19 [2]) and suitable for use in survival craft and, optionally, on board ships at sea. The requirements detailed in the Radio Regulations, International Convention for the Safety Of Life At Sea SOLAS 1974 and the International Maritime Organization Resolutions A.694(17) [4] and A.809(19) [3] are incorporated in the present document.
The present document states the minimum technical characteristics required for portable VHF radiotelephones operating in the bands between 156 MHz and 174 MHz allocated to the Maritime Mobile Services by the Radio Regulations (see Radio Regulations, Appendices 18 [1] and 19 [2]) and suitable for use in survival craft and, optionally, on board ships at sea. The requirements detailed in the Radio Regulations, International Convention for the Safety Of Life At Sea SOLAS 1974 and the International Maritime Organization Resolutions A.694(17) [4] and A.809(19) [3] are incorporated in the present document.
SIST EN 300 225 V1.4.1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.100.01 - Electromagnetic compatibility in general; 47.020.70 - Navigation and control equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 225 V1.4.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 3 Abbreviations
- 9 ETSI EN 300 225 V1.4.1 (2004-12)
- 4 General requirements
- 4.1 Construction
- 4.2 Frequencies and power
- 10 ETSI EN 300 225 V1.4.1 (2004-12)
- 4.3 Controls
- 4.4 Switching time
- 4.5 Safety precautions
- 4.6 Class of emission and modulation characteristics
- 11 ETSI EN 300 225 V1.4.1 (2004-12)
- 4.7 Battery
- 4.8 Labelling
- 5 Test conditions, power sources and ambient
- 5.1 Normal and extreme test conditions
- 5.2 Test power source
- 12 ETSI EN 300 225 V1.4.1 (2004-12)
- 5.3 Normal test conditions
- 5.4 Extreme test conditions
- 13 ETSI EN 300 225 V1.4.1 (2004-12)
- 5.5 Procedure for tests at extreme temperatures
- 6 General conditions of measurement
- 6.1 Test connections
- 6.2 Arrangements for test signals applied to the receiver input
- 6.3 Receiver mute or squelch facility
- 6.4 Normal test modulation
- 6.5 Artificial antenna
- 14 ETSI EN 300 225 V1.4.1 (2004-12)
- 6.6 Test channels
- 6.7 Measurement uncertainty and interpretation of the
- 15 ETSI EN 300 225 V1.4.1 (2004-12)
- 7 Environmental tests
- 7.1 Introduction
- 7.2 Procedure
- 7.3 Performance check
- 7.4 Drop test on hard surface
- 16 ETSI EN 300 225 V1.4.1 (2004-12)
- 7.5 Vibration test
- 7.6 Temperature tests
- 17 ETSI EN 300 225 V1.4.1 (2004-12)
- 18 ETSI EN 300 225 V1.4.1 (2004-12)
- 7.7 Corrosion test (sea water test)
- 19 ETSI EN 300 225 V1.4.1 (2004-12)
- 7.8 Immersion test
- 7.9 Thermal shock
- 7.10 Solar radiation
- 20 ETSI EN 300 225 V1.4.1 (2004-12)
- 7.11 Oil resistance test
- 8 Field measurement
- 8.1 General
- 8.2 Transmitter Effective Radiated Power (ERP)
- 21 ETSI EN 300 225 V1.4.1 (2004-12)
- 8.3 Spurious emissions from the transmitter
- 22 ETSI EN 300 225 V1.4.1 (2004-12)
- 8.4 Spurious emissions from the receiver
- 9 Transmitter
- 9.1 General
- 9.2 Frequency error
- 23 ETSI EN 300 225 V1.4.1 (2004-12)
- 9.3 Carrier power referenced to ERP
- 9.4 Frequency deviation
- 24 ETSI EN 300 225 V1.4.1 (2004-12)
- 9.5 Limitation characteristics of the modulator
- 25 ETSI EN 300 225 V1.4.1 (2004-12)
- 9.6 Sensitivity of the modulator, including microphone
- 9.7 Audio frequency response
- 9.8 Audio frequency harmonic distortion of the emission
- 26 ETSI EN 300 225 V1.4.1 (2004-12)
- 9.9 Adjacent channel power
- 27 ETSI EN 300 225 V1.4.1 (2004-12)
- 9.10 Residual modulation of the transmitter
- 9.11 Transient frequency behaviour of the transmitter
- 28 ETSI EN 300 225 V1.4.1 (2004-12)
- 29 ETSI EN 300 225 V1.4.1 (2004-12)
- 30 ETSI EN 300 225 V1.4.1 (2004-12)
- 31 ETSI EN 300 225 V1.4.1 (2004-12)
- 10 Receiver
- 10.1 Harmonic distortion and rated audio frequency output power
1 Scope
The present document states the minimum technical characteristics required for portable VHF radiotelephones operating in the bands between 156 MHz and 174 MHz allocated to the Maritime Mobile Services by the Radio Regulations (see Radio Regulations, Appendices 18 [1] and 19 [2]) and suitable for use in survival craft and, optionally, on board ships at sea. The requirements detailed in the Radio Regulations, International Convention for the Safety Of Life At Sea SOLAS 1974 and the International Maritime Organization Resolutions A.694(17) [4] and A.809(19) [3] are incorporated in the present document.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
[1] ITU Radio Regulations, Appendix 18: "Table of transmitting frequencies in the VHF maritime mobile band".
[2] ITU Radio Regulations, Appendix 19: "Technical characteristics of emergency position-indicating radiobeacons operating on the carrier frequency 2 182 kHz".
[3] International Maritime Organization Resolution A.809(19): "Performance standards for survival craft two way VHF radiotelephone apparatus".
[4] International Maritime Organization Resolution A.694(17): "General Requirements for Shipborne Radio Equipment Forming Part of the Global Maritime Distress and Safety System (GMDSS) and for Electronic Navigational Aids".
[5] ETSI TR 100 028 (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [6] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits". [7] ETSI EN 300 019 (all parts): "Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment".
[8] ISO 694: "Ships and marine technology - Positioning of magnetic compasses in ships". [9] International Maritime Organisation: "International Convention for the Safety Of Life At Sea (SOLAS)".
3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ad amplitude difference DSC Digital Selective Calling emf electro-motive force ERP Effective Radiated Power fd frequency difference ETSI
SIST EN 300 225 V1.4.1:2006
9 ETSI EN 300 225 V1.4.1 (2004-12)
IF Intermediate Frequency MMS Maritime Mobile Service RF Radio Frequency rms root mean square SINAD (Signal + Noise + Distortion)/(Noise + Distortion) ratio SOLAS International Convention for the Safety of Life at Sea
4 General requirements
4.1 Construction
The equipment shall be portable and capable of being used for on-scene communications between survival craft, between survival craft and ship and between survival craft and rescue unit. It may also be used for on-board communications when capable of operating on appropriate frequencies. The equipment shall comprise at least:
- an integral transmitter/receiver including antenna and battery;
- an integral control unit including a press-to-transmit switch; and
- an internal microphone and loudspeaker.
The equipment shall be of either, highly visible yellow or orange colour, or marked with a surrounding highly visible yellow or orange marking strip, which shall be visible also during charging and storage, as applicable. The mechanical and electrical construction and finish of the equipment shall conform in all respects to good engineering practice and the equipment shall be suitable for use on board ships and survival craft at sea. All controls shall be of sufficient size to enable the usual control functions to be easily performed by a user wearing gloves for immersion suits, in accordance with SOLAS 1974 Chapter III, Regulation 32 [9]. The number of controls should be the minimum necessary for simple and satisfactory operation. With the possible exception of channel selection, it shall be possible to operate the equipment using only one hand. Any parts of the equipment required to be checked during inspection or maintenance operations as laid down by the manufacturer, shall be readily accessible. Components shall be readily identifiable. For the purpose of conformance testing in accordance with the present document, adequate technical and operational documentation shall be supplied with the equipment.
The equipment shall not be unduly affected by sea water, oil, or exposure to sunlight. The equipment shall be of small size and light weight (not more than 1,5 litres and 1,5 kg). The equipment shall have provisions for its attachment to the clothing of the user and also be provided with a wrist or neck strap. For safety reasons, the strap should include a suitable weak link to prevent the bearer from being ensnared. The manufacturer shall provide evidence on the method of attaching the equipment to the user's clothing, including the immersion suit specified in SOLAS 1974 Chapter III, Regulation 32 [9]. The manufacturer shall supply documentary proof of compliance with this requirement.
4.2 Frequencies and power
The equipment shall operate only on single-frequency channels for voice communications with manual control (simplex).
The equipment shall provide for transmission and reception of signals on channel 16 and at least one other single frequency channel from those specified in Appendix 18 of the Radio Regulations [1], (with the exception of the DSC calling channel 70), (see also clause 6.6).
Independent selection of transmitting and receiving frequencies shall not be possible. ETSI
SIST EN 300 225 V1.4.1:2006
10 ETSI EN 300 225 V1.4.1 (2004-12)
After switch on the equipment shall be operational within 5 seconds and meet the requirements of the present document within 1 minute.
It shall not be possible to transmit during channel switching operations.
4.3 Controls
The equipment shall have a channel selector and shall indicate the designator of the channel at which the equipment is set, as given in Appendix 18 of the Radio Regulations [1].
It shall be possible to determine that channel 16 has been selected in all ambient light conditions. The equipment shall have the following additional controls:
- on/off switch for the equipment with a visual indication that the equipment is switched on;
- a manual non-locking push to talk switch to operate the transmitter;
- a switch for reducing the power to not exceed 1 watt ERP; if the transmitter ERP is greater than 1 watt;
- an audio-frequency volume control;
- a squelch control;
- a carrier power detector giving a visual indication that the carrier is being produced. The user shall not have access to any control which may impair the technical characteristics of the equipment if wrongly set.
4.4 Switching time
The channel switching arrangements shall be such that the time necessary to change over from using one of the channels to using any other channel does not exceed 5 seconds. The time necessary to change over from transmission to reception and vice versa, shall not exceed 0,3 seconds.
4.5 Safety precautions
Means shall be incorporated to prevent damage to the equipment due to reversal of polarity of the battery power supply. The equipment shall be designed to be free of sharp projections which could damage survival craft. The manufacturer shall declare the survival craft compass safe distance according to ISO Recommendation 694 [8]. The equipment shall not be damaged by the effects of an open circuit or a short circuit of the antenna.
4.6 Class of emission and modulation characteristics
The equipment shall use phase modulation, G3E (frequency modulation with a pre-emphasis of 6 dB/octave) for speech.
The equipment shall be designed to operate satisfactorily to the requirements of the present document with a channel separation of 25 kHz.
The frequency deviation corresponding to 100 % modulation shall approach ±5 kHz as nearly as practicable. ETSI
SIST EN 300 225 V1.4.1:2006
11 ETSI EN 300 225 V1.4.1 (2004-12)
4.7 Battery
The battery shall be integrated in the equipment. In addition provision may be made to operate the equipment using an external power source.
The equipment shall be capable of operating with primary batteries. In addition the equipment may be capable of operating with secondary batteries.
Primary batteries shall have a shelf life of at least two years. Primary batteries shall have a colour and marking as described in clause 4.1. Secondary batteries shall not have the same colour or marking as the primary batteries. The capacity of the integral primary battery shall be sufficient to operate the equipment continuously for at least eight hours at any temperature condition (see clauses 5.3.1 and 5.4.1) with a 1:9 transmit to receive duty cycle at the highest rated transmit power.
This duty cycle is defined as:
- 6 s transmit at full RF output power without modulation, 6 s reception with an RF input signal at the nominal frequency of the receiver at a level of +60 dBμV using normal test modulation (see clause 6.4); and
- the audio volume control of the receiver set at maximum followed by 48 s reception without input signal and the squelch control operational (muted).
Provisions shall be made for replacing the battery easily without the use of special tools and without degrading the performance of the equipment (particularly water tightness after re-assembly). If the equipment is capable of operation with secondary batteries, see clause 11.
4.8 Labelling
All controls and indicators shall be clearly labelled.
The equipment shall be clearly labelled with brief instructions for operation. The equipment shall be clearly marked on the exterior with identification of the manufacturer, type designation, serial number and the compass safe distance.
The type and designation of the battery used and the expiry date of any primary battery shall be clearly labelled.
5 Test conditions, power sources and ambient
temperatures
5.1 Normal and extreme test conditions
Conformance testing shall be made under normal test conditions and also, where stated, under extreme test conditions.
5.2 Test power source
During conformance testing, the equipment shall be supplied from a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The tests power source shall only be used in measurements where its effect on the test results shall be negligible. For the purpose of testing the power source voltage shall be measured at the input terminals of the equipment.
During testing, the power source voltages shall be maintained within a tolerance of ±3 % relative to the voltage level at the beginning of each test.
ETSI
SIST EN 300 225 V1.4.1:2006
12 ETSI EN 300 225 V1.4.1 (2004-12)
The test power source shall only be used in measurements where the use of the test power source is mutually agreed between manufacturer and test house. In the event of any discrepancy, results obtained using the batteries shall take precedence over results obtained using the test power source.
5.3 Normal test conditions
5.3.1 Normal temperature and humidity
The normal temperature and humidity conditions for tests shall be a combination of temperature and humidity within the following limits:
- temperature +15°C to +35°C;
- relative humidity 20 % to 75 %.
5.3.2 Normal power source
The normal test voltage shall be the nominal voltage of the primary battery as declared by the manufacturer.
5.4 Extreme test conditions
5.4.1 Extreme temperatures
5.4.1.1 Upper extreme temperature
For tests at the upper extreme temperature, measurements shall be made at a temperature of +55°C.
5.4.1.2 Lower extreme temperature
For tests at the lower extreme temperature, measurements shall be made at a temperature of -20°C.
5.4.2 Extreme test power supply values
5.4.2.1 Upper extreme test voltage
The upper extreme test voltage shall be determined in each case and shall be the voltage corresponding to the voltage that the primary battery gives at the upper extreme temperature at the beginning of the battery test cycle (see clause 4.7) with a load equal to that of the equipment in the muted receive position.
5.4.2.2 Lower extreme test voltage
The equipment fitted with an unused primary battery shall be placed in a climatic chamber and cooled to -20°C allowing a stabilization period of two hours. The equipment shall be activated as described in clause 4.7 for a period of eight hours. After this period the battery voltage shall be measured during equipment transmission. If the equipment is capable of operating with secondary batteries, it shall be fitted with a fully charged secondary battery and placed in a climatic chamber and cooled to -20°C allowing a stabilization period of two hours. After this period the battery voltage shall be measured during equipment transmission. The lower voltage measured shall be taken as the extreme lower test voltage. ETSI
SIST EN 300 225 V1.4.1:2006
13 ETSI EN 300 225 V1.4.1 (2004-12)
5.5 Procedure for tests at extreme temperatures
The equipment shall be switched off during the temperature-stabilizing periods. Before conducting tests at the upper temperature, the equipment shall be placed in the test chamber and left until thermal equilibrium is reached. The equipment shall then be switched on for half an hour during which the transmitter shall be keyed with a duty cycle of 5 minute transmission in the high power transmit condition and 5 minute reception. The equipment shall meet the requirements of the present document after this period. For tests at the lower temperature, the equipment shall be left in the test chamber until thermal equilibrium is reached and shall then be switched to the standby or receive position for one minute, after which the equipment shall meet the requirements of the present document.
6 General conditions of measurement
6.1 Test connections
For the purposes of conformance testing, the manufacturer and the test house shall agree on suitable connections to test points within the equipment, which allow easy access to:
- the transmitter output (for 50 Ω connection);
- the receiver input (for 50 Ω connection);
- the transmitter audio input(s);
- the receiver audio output(s);
- the push-to-talk switch.
6.2 Arrangements for test signals applied to the receiver input
Test signal generators shall be connected to the receiver input in such a way that the impedance presented to the receiver input is 50 Ω, irrespective of whether one or more test signals are applied to the receiver simultaneously. The levels of the test signals shall be expressed in terms of the emf at the terminals to be connected to the receiver. The effects of any intermodulation product and noise product in the test signal generators should be negligible. The nominal frequency of the receiver is the carrier frequency of the selected channel.
6.3 Receiver mute or squelch facility
Unless otherwise specified, the receiver squelch facility shall be made inoperative for the duration of the conformance tests.
6.4 Normal test modulation
For normal test modulation, the modulation frequency shall be 1 kHz and the frequency deviation shall be ±3 kHz.
6.5 Artificial antenna
When tests are conducted with an artificial antenna, this shall be a 50 Ω non-reactive, non-radiating load. ETSI
SIST EN 300 225 V1.4.1:2006
14 ETSI EN 300 225 V1.4.1 (2004-12)
6.6 Test channels
Conformance testing shall be made on channel 16 (safety) unless otherwise stated. For the purpose of field measurement conformance testing, the equipment shall also be capable of operating on channel 17.
6.7 Measurement uncertainty and interpretation of the
measuring results
6.7.1 Measurement uncertainty
Absolute measurement uncertainties: maximum values
RF frequency ±1 × 10 RF power ±0,75 dB Maximum frequency deviation:
- within 300 Hz to 6 kHz of audio frequency ±5 %
- within 6 kHz to 25 kHz of audio frequency ±3 dB Deviation limitation ±5 % Adjacent channel power ±5 dB Audio output power ±0,5 dB Amplitude characteristics of receiver limiter ±1,5 dB Sensitivity at 20 dB SINAD ±3 dB Two signal measurement ±4 dB Three signal measurement ±3 dB Radiated emission of transmitter ±6 dB Radiated emission of receiver ±6 dB Transmitter transient time ±20 % Transmitter transient frequency ±250 Hz For the test methods according to the present document the uncertainty figures are valid to a confidence level of 95 % calculated according to the methods described in TR 100 028 [5].
6.7.2 Interpretation of the measurement results
The interpretation of the results recorded in a test report for the measurements described in the present document shall be as follows:
- the measured value related to the corresponding limit will be used to decide whether an equipment meets the requirements of the present document;
- the measurement uncertainty value for the measurement of each parameter shall be included in the test report;
- the recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the maximum values given above.
NOTE: This procedure for using maximum acceptable uncertainty values is valid until superseded by other appropriate publications of ETSI covering this subject.
ETSI
SIST EN 300 225 V1.4.1:2006
15 ETSI EN 300 225 V1.4.1 (2004-12)
The use of the measured value has been chosen because there is no other ETSI standard covering the subject at the time of publication of the present document. Therefore the measurement uncertainty shall be used as a quality of the actual measurement. The measurement uncertainty values may also be used by Accreditation Authorities during their accreditation procedures to ensure compliance with the requirements of conformance testing to ETSI standards.
7 Environmental tests
7.1 Introduction
The tests in this clause are performed in order to simulate the environment in which the equipment is intended to operate. Classification of other environmental conditions may be found in EN 300 019 [7].
7.2 Procedure
Environmental tests shall be carried out before tests of the same equipment in respect to the other requirements of the present document are performed. The following tests shall be carried out in the order they appear in this clause. Unless otherwise stated, the equipment shall be connected to an electrical power source only during the periods for which it is specified that electrical tests shall be carried out. These shall be done with normal test voltage.
7.3 Performance check
For the purpose of the present document, the term performance check shall be taken to mean a check of the transmitter output power as specified in clause 9.2 (high power only), the transmitter frequency error as specified in clause 9.1 and receiver sensitivity as specified in clause 10.3.
The performance check shall only be made on channel 16 and the carrier power shall be between 0,25 W and 25 W, the frequency error shall be less than ±1,5 kHz and the receiver sensitivity shall be better than +12 dBµV (emf).
7.4 Drop test on hard surface
7.4.1 Definition
The immunity against the effects of dropping is the ability of the equipment to maintain the specified mechanical and electrical performance after being subjected to a series of drops on a hard wooden test surface.
...