kSIST FprEN 882:2026
(Main)Chemicals used for treatment of water intended for human consumption - Sodium aluminate
- Abstract
This document is applicable to sodium aluminate used for treatment of water intended for human consumption. It describes the characteristics and specifies the requirements of sodium aluminate and refers to the corresponding analytical methods. It gives information for its use in water treatment. It also specifies the rules relating to safe handling (Annex B) and describes the use of sodium aluminate (Annex A).
- Status
- Not Published
- Public Enquiry End Date
- 15-Oct-2025
- Technical Committee
- IOVO - Water supply and waste water engineering
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 28-Aug-2026
- Due Date
- 16-Oct-2026
- Completion Date
- 02-Sep-2026
kSIST FprEN 882:2026 is a draft standard for sodium aluminate used in the treatment of water intended for human consumption. It specifies how the product is identified, what purity limits apply, how it is tested, and what information is needed for delivery, labelling, storage and safe handling. It is written for manufacturers, suppliers, laboratories and water-treatment users who need a common product specification.
What does kSIST FprEN 882:2026 specify?
kSIST FprEN 882:2026 applies to sodium aluminate used for treating water intended for human consumption. It describes the product, sets purity criteria, points to the analytical methods to use, and gives guidance on use in water treatment.
The document is organized into seven clauses and two annexes. Clause 4 identifies and describes the material, Clause 5 sets purity criteria, Clause 6 covers test methods, and Clause 7 covers labelling, transport and storage. Annex A gives general information on sodium aluminate use, and Annex B gives safety rules.
| Annex | What it covers |
|---|---|
| Annex A | General information on sodium aluminate, including origin, manufacture, quality, use, dose, application and removal of excess product |
| Annex B | General rules relating to safety, including safe handling and emergency procedures |
The introduction also notes that conformity with the document does not by itself mean the product is accepted in every EU or EFTA Member State. In practice, users still need to check the national rules that apply where the product will be used.
What are the key requirements of kSIST FprEN 882:2026?
kSIST FprEN 882:2026 is mainly a product specification. The most important requirements are the identification of the chemical, the purity limits, the test methods, and the controls for delivery, labelling and storage.
Product identification and form
Clause 4 identifies sodium aluminate by chemical names, its common name, formula information, and registry numbers. It also says the product is supplied as solids or solutions. For a buyer or laboratory, this helps make sure the product ordered, received and tested is the correct chemical and not another aluminium compound.
Clause 4 also describes the physical form: solids may be powder or granules, while solutions may be colourless to yellow liquid. The document gives physical property data such as density, solubility, viscosity and melting or crystallization behavior. These details matter because they affect pumping, dilution, storage and handling on site.
Purity criteria and impurity control
Clause 5 sets minimum purity requirements for sodium aluminate used in water treatment. The active matter content in the commercial product, expressed as aluminium, must stay within the tolerance stated against the manufacturer's declared value. That matters for dose control, because the treatment effect depends on the actual aluminium content.
Clause 5 also limits impurities and main by-products. Table 2 sets limits for iron and insoluble matter in solid product. Table 3 sets limits for key chemical parameters, including arsenic, cadmium, chromium, mercury, nickel, lead, antimony and selenium, and groups products into three parameter types. In practice, this is the part users check when they need to match a product grade to raw water quality and treated-water objectives.
The annex adds a practical warning: the selected grade can affect trace metals in the treated water, so the product grade should be chosen with the raw water, dose, process conditions and local water-quality targets in mind.
Test methods
Clause 6 is simple but important: sampling and analysis must use the relevant methods in EN 1302. That means the product is not tested with an arbitrary in-house method if conformity is being checked. For quality control and acceptance testing, users need the EN 1302 methods for aluminium-based coagulants.
Delivery, labelling, transport and storage
Clause 7 controls how the product is delivered and stored. Solids should be delivered in suitable packages or lined bulk trucks, and liquid product should be delivered in corrosion-resistant tankers. Delivery equipment must not have been used previously for another product unless it has been cleaned and prepared. This helps prevent contamination that could affect purity or safety.
Clause 7 also points to EU labelling requirements and transport rules. The document associates the product with corrosive hazard labelling and gives transport entries for solid and solution forms. For logistics teams, this is the section that drives packaging, shipping documents, warehouse handling and hazard communication.
Storage guidance is practical as well. Solution tanks should be made of corrosion-resistant material, and external tanks may need protection against freezing or excessive viscosity increase. The product must also be kept away from incompatible substances such as acids and several metals and metal salts. This matters because sodium aluminate is strongly alkaline and can react aggressively with some materials.
Use and safety
Annex A describes sodium aluminate as a coagulant and flocculant. It explains how it is typically diluted before use, gives guidance on usual dosing, describes how it is applied, and lists expected secondary effects such as increased pH and alkalinity. It also explains how excess product should be removed during treatment so that aluminium levels are reduced in the finished water.
Annex B sets the safety approach. The supplier must provide current safety instructions, and the annex gives procedures for accidental contact, spillage and fire. In practical terms, it tells operators how to respond quickly if the product is spilled, inhaled, ingested or splashed.
Who uses kSIST FprEN 882:2026?
kSIST FprEN 882:2026 is used by people who specify, supply, receive, test and apply sodium aluminate in drinking-water treatment. Typical users include:
- water utility and treatment-plant operators, for dosing and process control
- procurement and quality managers, for product specification and supplier checks
- manufacturers and suppliers, for product declaration, labelling and transport
- laboratory staff, for sampling and analysis against EN 1302
- transport and warehouse teams, for packaging, incompatibility control and storage conditions
The standard is especially relevant where sodium aluminate is used as a coagulant or flocculant and where the operator must manage pH, alkalinity and trace-metal carryover.
What changed in kSIST FprEN 882:2026 from the previous edition?
kSIST FprEN 882:2026 supersedes EN 882:2016. The change stated in the document is an update of the information related to the Drinking Water Directive.
Which standards are used with kSIST FprEN 882:2026?
kSIST FprEN 882:2026 names EN 1302 as its normative reference. EN 1302 provides the sampling and analytical methods used for this product family.
The bibliography also points to Directive (EU) 2020/2184 and Regulation (EC) No 1272/2008. The directive is used as the drinking-water policy reference in the annexed trace-metal discussion, and the regulation supports the labelling approach for classification and packaging.
What does the kSIST FprEN 882:2026 document contain?
kSIST FprEN 882:2026 contains identification data, physical-property data, purity requirements, analytical references, transport and storage guidance, and safety information. It also includes a viscosity table and annexed tables showing the effect of product grade on trace metals in treated water.
The document gives practical guidance on dilution, dosing, application by metering pump, and removal of excess aluminium during treatment. It also gives emergency actions for accidents, spillages and fire, which makes it useful not only for purchasing and specification work but also for plant operation and operator training.
Relations
- Effective Date
- 19-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.
Sponsored listings
Frequently Asked Questions
kSIST FprEN 882:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Chemicals used for treatment of water intended for human consumption - Sodium aluminate". This standard covers: This document is applicable to sodium aluminate used for treatment of water intended for human consumption. It describes the characteristics and specifies the requirements of sodium aluminate and refers to the corresponding analytical methods. It gives information for its use in water treatment. It also specifies the rules relating to safe handling (Annex B) and describes the use of sodium aluminate (Annex A).
This document is applicable to sodium aluminate used for treatment of water intended for human consumption. It describes the characteristics and specifies the requirements of sodium aluminate and refers to the corresponding analytical methods. It gives information for its use in water treatment. It also specifies the rules relating to safe handling (Annex B) and describes the use of sodium aluminate (Annex A).
kSIST FprEN 882:2026 is classified under the following ICS (International Classification for Standards) categories: 13.060.20 - Drinking water; 71.100.80 - Chemicals for purification of water. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN 882:2026 has the following relationships with other standards: It is inter standard links to SIST EN 882:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
kSIST FprEN 882:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 882:2025
01-oktober-2025
Kemikalije, ki se uporabljajo za pripravo pitne vode - Natrijev aluminat
Chemicals used for treatment of water intended for human consumption - Sodium
aluminate
Produkte zur Aufbereitung von Wasser für den menschlichen Gebrauch -
Natriumaluminat
Produits chimiques utilisés pour le traitement de l'eau destinée à la consommation
humaine - Aluminate de sodium
Ta slovenski standard je istoveten z: prEN 882
ICS:
13.060.20 Pitna voda Drinking water
71.100.80 Kemikalije za čiščenje vode Chemicals for purification of
water
oSIST prEN 882:2025 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST prEN 882:2025
oSIST prEN 882:2025
DRAFT
EUROPEAN STANDARD
prEN 882
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2025
ICS 71.100.80 Will supersede EN 882:2016
English Version
Chemicals used for treatment of water intended for human
consumption - Sodium aluminate
Produits chimiques utilisés pour le traitement de l'eau Produkte zur Aufbereitung von Wasser für den
destinée à la consommation humaine - Aluminate de menschlichen Gebrauch - Natriumaluminat
sodium
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 164.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 882:2025 E
worldwide for CEN national Members.
oSIST prEN 882:2025
prEN 882:2025 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Description . 6
4.1 Identification . 6
4.1.1 Chemical name . 6
4.1.2 Synonym or common name . 6
4.1.3 Relative molecular mass . 6
4.1.4 Empirical formula . 6
4.1.5 Chemical formula . 7
4.1.6 CAS Registry Number . 7
4.1.7 EINECS reference . 7
4.2 Commercial form . 7
4.3 Physical properties . 7
4.3.1 Appearance . 7
4.3.2 Density . 7
4.3.3 Solubility . 7
4.3.4 Vapour pressure . 7
4.3.5 Boiling point at 100 kPa . 8
4.3.6 Melting or crystallization point . 8
4.3.7 Specific heat . 8
4.3.8 Viscosity (dynamic) . 8
4.3.9 Critical temperature . 8
4.3.10 Critical pressure . 8
4.3.11 Physical hardness . 8
4.4 Chemical properties . 9
5 Purity criteria . 9
5.1 General . 9
5.2 Composition of commercial product . 9
5.3 Impurities and main by-products . 10
5.4 Chemical parameters . 10
6 Test methods . 10
6.1 Sampling . 10
6.2 Analyses . 11
7 Labelling – Transportation – Storage . 11
7.1 Means of delivery . 11
7.2 Labelling in accordance with the EU legislation . 11
7.3 Transportation regulations and labelling . 12
7.4 Marking . 12
7.5 Storage . 12
7.5.1 General . 12
oSIST prEN 882:2025
prEN 882:2025 (E)
7.5.2 Long term stability . 13
7.5.3 Storage incompatibilities . 13
Annex A (informative) General information on sodium aluminate . 14
A.1 Origin . 14
A.1.1 Raw materials . 14
A.1.2 Manufacturing process . 14
A.2 Quality of commercial product . 14
A.3 Use . 16
A.3.1 Function . 16
A.3.2 Form in which it is used. 16
A.3.3 Treatment dose . 16
A.3.4 Means of application . 16
A.3.5 Secondary effects . 16
A.3.6 Removal of excess product . 17
Annex B (normative) General rules relating to safety . 18
B.1 Rules for safe handling and use . 18
B.2 Emergency procedures . 18
B.2.1 Accident . 18
B.2.2 Spillage . 18
B.2.3 Fire . 18
Bibliography . 19
oSIST prEN 882:2025
prEN 882:2025 (E)
European foreword
This document (prEN 882:2025) has been prepared by Technical Committee CEN/TC 164 “Water
supply”, the secretariat of which is held by AFNOR.
This document has been submitted to the CEN Enquiry.
This document will supersede EN 882:2016.
Significant technical differences between this edition prEN 882:2025 and EN 882:2016 are as follows:
a) update of the information related to Drinking Water Directive.
oSIST prEN 882:2025
prEN 882:2025 (E)
Introduction
In respect of potential adverse effects on the quality of water intended for human consumption, caused
by the product covered by this document:
a) this document provides no information as to whether the product may be used without restriction
in any of the Member States of the EU or EFTA;
b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national
regulations concerning the use and/or the characteristics of this product remain in force.
NOTE Conformity with this document does not confer or imply acceptance or approval of the product in any of
the Member States of the EU or EFTA. The use of the product covered by this document is subject to regulation or
control by National Authorities.
oSIST prEN 882:2025
prEN 882:2025 (E)
1 Scope
This document is applicable to sodium aluminate used for treatment of water intended for human
consumption. It describes the characteristics and specifies the requirements of sodium aluminate and
refers to the corresponding analytical methods. It gives information for its use in water treatment. It also
determines the rules relating to safe handling (Annex B) and use of sodium aluminate (Annex A).
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 1302, Chemicals used for treatment of water intended for human consumption — Aluminium-based
coagulants — Analytical methods
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
4 Description
4.1 Identification
4.1.1 Chemical name
Aluminium sodium oxide
Aluminium sodium dioxide
Aluminium sodium tetrahydroxide
4.1.2 Synonym or common name
Sodium aluminate
4.1.3 Relative molecular mass
82 for NaAlO .
4.1.4 Empirical formula
a) NaAlO .
b) NaAlO 0,1 Na O⋅nH O (n varies from 0,3 to 0,4).
2 2 2
...