SIST EN 14382:2019+A1:2025
(Main)Gas safety shut-off devices for inlet pressure up to 10 MPa (100 bar)
Gas safety shut-off devices for inlet pressure up to 10 MPa (100 bar)
Continued integrity of safety shut-off devices is ensured by periodic functional checks. For periodic
functional checks it is common to refer to national regulations/standards where existing or
users/manufacturers practices.
This document considers the reaction of the SSDs functional class A to the specified reasonable
expected failures in terms of “fail close” behaviour, but it should be consider that there are other types
of failures whose consequences cannot bring to the same reactions (these risks are covered via
redundancy as per EN 12186) and that residual hazards should be reduced by a suitable surveillance in
use / maintenance.
In this document, both safety shut-off devices that can be classified as “safety accessories” by
themselves according the Pressure Equipment Directive (2014/68/EU) as well as safety shut-off
devices that can be used to provide the necessary pressure protection through redundancy (e.g. shutoff
device integrated in a pressure regulator, shut-off device with a second shut-off device) are considered.
Addition of environmental considerations;
The provisions in this document are in line with the state of art at the moment of writing.
This document does not intend to limit the improvement of actual provisions (materials, requirements,
test methods, acceptance criteria, etc.) or the developing of new provisions for SSDs where they are
suitable to ensure an equivalent level of reliability.
Some clauses of this standard should be re-considered at the time when characteristics for nonconventional
gases will be available.
Gas safety shut-off devices according to this European standard do not have their own source of ignition
and therefore are not within the scope of European Directive 2014/34/EU. Any additional component
(e.g. proximity switch, travel transducer etc.) should be independently considered in the framework of
assemblies per ATEX Guideline to the application of Directive 2014/34/EU of the European Parliament
and of the Council of 26nd February 2014, edition December 2017, §§42 and 43.
The document includes also environmental considerations.
Gas-Sicherheitsabsperreinrichtungen für Eingangsdrücke bis 10 MPa (100 bar)
No scope available
Dispositifs de sécurité pour postes et installations de détente-régulation de pression de gaz - Clapets de sécurité pour pressions amont jusqu'à 10 MPa (100 bar)
No scope available
Plinske varnostne zaporne naprave za vstopne tlake do 10 MPa (100 bar) (vključno z dopolnilom A1)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2025
Nadomešča:
SIST EN 14382:2019
Plinske varnostne zaporne naprave za vstopne tlake do 10 MPa (100 bar) (vključno
z dopolnilom A1)
Gas safety shut-off devices for inlet pressure up to 10 MPa (100 bar)
Gas-Sicherheitsabsperreinrichtungen für Eingangsdrücke bis 10 MPa (100 bar)
Dispositifs de sécurité pour postes et installations de détente-régulation de pression de
gaz - Clapets de sécurité pour pressions amont jusqu'à 10 MPa (100 bar)
Ta slovenski standard je istoveten z: EN 14382:2019+A1:2024
ICS:
23.060.40 Tlačni regulatorji Pressure regulators
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 14382:2019+A1
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2024
EUROPÄISCHE NORM
ICS 23.060.40 Supersedes EN 14382:2019
English Version
Gas safety shut-off devices for inlet pressure up to 10 MPa
(100 bar)
Dispositifs de sécurité pour postes et installations de Gas-Sicherheitsabsperreinrichtungen für
détente-régulation de pression de gaz - Clapets de Eingangsdrücke bis 10 MPa (100 bar)
sécurité pour pressions amont jusqu'à 10 MPa (100
bar)
This European Standard was approved by CEN on 23 April 2019 and includes Amendment approved by CEN on 22 October
2023.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14382:2019+A1:2024 E
worldwide for CEN national Members.
Contents Page
European foreword . 5
1 Scope . 6
2 Normative references . 7
3 Terms and definitions . 8
3.1 General terms and definition of type of gas safety shut-off devices . 8
3.2 Terms and definition of components of safety devices . 9
3.3 Terms, symbols and definitions related to the functional performance . 15
3.4 Possible values of all variables. 16
3.5 Terms, symbols and definitions related to the set value of the trip pressure . 16
3.6 Terms, symbols and definitions related to the flow . 17
3.7 Terms, symbols and definitions related to accuracy and some other performances . 17
3.8 Terms, symbols and definitions related to the design and tests . 18
3.9 Summary of symbols, terms, subclauses and units. 20
4 Construction requirements . 21
4.1 Basic requirements . 21
4.2 Materials . 24
4.3 Strength of housings and other parts. 25
4.4 Strength of elastomeric diaphragms . 28
5 Functional and characteristic requirements . 29
5.1 General . 29
5.2 Accuracy group . 30
5.3 Response time . 31
5.4 Relatching difference and unlatching . 31
5.5 Closing force . 31
5.6 Endurance and accelerated ageing . 32
5.7 Strength of the trip mechanism, valve seat and closing member against the dynamic
impact of flowing gas . 32
5.8 Antistatic characteristics . 32
5.9 Flow coefficient . 32
5.10 Final visual inspection . 32
6 Testing . 33
6.1 General . 33
6.2 Tests . 33
6.3 Type test . 34
6.4 Selection of test samples . 34
6.5 Routine tests . 35
6.6 Production surveillance . 35
7 Test and verification methods . 35
7.1 Dimensional check and visual inspection . 35
7.2 Materials check . 35
7.3 Verification of the strength of parts under pressure . 35
7.4 Verification of the strength of parts transmitting actuating forces . 35
7.5 Shell and inner metallic partition walls strength test . 36
7.6 Alternative shell and inner metallic partition walls strength test . 36
7.7 External tightness test . 36
7.8 Internal sealing test . 37
7.9 Test method and acceptance criteria to verify the antistatic characteristics . 37
7.10 Accuracy group . 37
7.11 Response time . 42
7.12 Relatching difference and unlatching . 43
7.13 Verification of closing force . 44
7.14 Endurance and accelerated ageing . 44
7.15 Resistance to gas of non-metallic parts . 44
7.16 Verification of the strength of the trip mechanism, valve seat and closing member
against dynamic impact of flowing gas . 44
7.17 Final visual inspection . 45
8 Field surveillance . 45
9 Documentation . 46
9.1 Documentation related to type test . 46
9.2 Documentation related to the routine tests . 46
9.3 Documentation related to production surveillance in accordance with 6.6 . 46
9.4 Operating instructions . 47
9.5 Information on sizing . 47
10 Marking . 48
10.1 General requirements . 48
10.2 Basic requirements . 48
10.3 Other additional requirements . 48
10.4 Markings for the various connections. 49
10.5 Identification of auxiliary devices . 49
11 Packaging and transportation of finished product . 49
Annex A (informative) Ice formation . 50
A.1 General . 50
A.2 Requirements . 50
A.3 Tests . 50
)
Annex B (informative) Compliance evaluation . 51
B.1 General . 51
B.2 Introduction. 51
B.3 Procedure . 51
B.4 Manufacturer’s compliance evaluation .
...