SIST EN 17124:2018
(Main)Hydrogen fuel - Product specification and quality assurance - Proton exchange membrane (PEM) fuel cell applications for road vehicles
Hydrogen fuel - Product specification and quality assurance - Proton exchange membrane (PEM) fuel cell applications for road vehicles
This European Standard specifies the quality characteristics of hydrogen fuel and the corresponding quality assurance in order to ensure uniformity of the hydrogen product as dispensed for utilisation in proton exchange membrane (PEM) fuel cell road vehicle systems.
Wasserstoff als Kraftstoff - Produktfestlegung und Qualitätssicherung - Protonenaustauschmembran (PEM) - Brennstoffzellenanwendungen für Straßenfahrzeuge
Dieses Dokument legt die Qualitätseigenschaften von Wasserstofftreibstoff und die zugehörige Qualitätssicherung fest, um eine Gleichförmigkeit des Wasserstoffprodukts sicherzustellen, das für die Nutzung in Fahrzeugsystemen mit Protonen-Austauschmembran-Brennstoffzellen (Proton Exchange Membrane, PEM) getankt wird.
Carburant hydrogène - Spécification de produit et assurance qualité - Applications des piles à combustible à membrane à échange de protons (MEP) pour les véhicules routier
La présente Norme européenne spécifie les caractéristiques de qualité du carburant hydrogène et l'assurance qualité correspondante, afin d'assurer l'uniformité du produit hydrogène tel que distribué pour une utilisation dans les systèmes de véhicules routiers à piles à combustible à membrane à échange de protons (MEP).
Vodik kot gorivo - Specifikacija izdelka in zagotavljanje kakovosti - Membrane za protonsko izmenjavo (PEM) - Gorivne celice za cestna vozila
Ta evropski standard določa kakovostne značilnosti vodika kot goriva in povezano zagotavljanje kakovosti za namene zagotavljanja enotnosti vodikovega izdelka za uporabo v sistemih cestnih vozil z gorivnimi celicami z membranami za protonsko izmenjavo (PEM).
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 17124:2018
01-december-2018
Vodik kot gorivo - Specifikacija izdelka in zagotavljanje kakovosti - Membrane za
protonsko izmenjavo (PEM) - Gorivne celice za cestna vozila
Hydrogen fuel - Product specification and quality assurance - Proton exchange
membrane (PEM) fuel cell applications for road vehicles
Wasserstoff als Kraftstoff - Produktfestlegung und Qualitätssicherung -
Protonenaustauschmembran (PEM) - Brennstoffzellenanwendungen für
Straßenfahrzeuge
Carburant hydrogène - Spécification de produit et assurance qualité - Applications des
piles à combustible à membrane à échange de protons (MEP) pour les véhicules routier
Ta slovenski standard je istoveten z: EN 17124:2018
ICS:
27.075 Tehnologija vodika Hydrogen technologies
SIST EN 17124:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 17124:2018
---------------------- Page: 2 ----------------------
SIST EN 17124:2018
EN 17124
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2018
EUROPÄISCHE NORM
ICS 27.075; 71.100.20
English Version
Hydrogen fuel - Product specification and quality
assurance - Proton exchange membrane (PEM) fuel cell
applications for road vehicles
Carburant hydrogène - Spécification de produit et Wasserstoff als Kraftstoff - Produktfestlegung und
assurance qualité - Applications des piles à Qualitätssicherung - Protonenaustauschmembran
combustible à membrane à échange de protons (MEP) (PEM) - Brennstoffzellenanwendungen für
pour les véhicules routier Straßenfahrzeuge
This European Standard was approved by CEN on 28 May 2018.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 17124:2018 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Requirements . 6
5 Hydrogen Quality Control Approaches . 7
5.1 General requirements . 7
5.2 Sampling . 8
5.3 Monitoring . 8
6 Hydrogen Quality Assurance Methodology . 8
6.1 General Requirements – Potential sources of impurities . 8
6.2 Prescriptive Approach for Hydrogen Quality Assurance . 8
6.3 Risk Assessment for Hydrogen and Quality Assurance . 8
7 Routine Quality Control . 12
8 Non-routine Quality Control . 12
9 Non compliances . 13
Annex A (informative) Impact of impurities . 14
A.1 General . 14
A.2 Inert Gases: Argon, Nitrogen . 14
A.3 Oxygen. 14
A.4 Carbon Dioxide . 14
A.5 Carbon Monoxide . 14
A.6 Methane . 15
A.7 Water . 15
A.8 Total sulphur compounds . 15
A.9 Ammonia . 15
A.10 Total Hydrocarbons . 15
A.11 Formaldehyde . 16
A.12 Formic Acid . 16
A.13 Halogenated Compounds . 16
A.14 Helium . 16
A.15 Solid and liquid particulates (Aerosols) . 16
Annex B (informative) Example of Supply chain evaluation with regards to potential sources
of impurities . 18
B.1 Potential Sources of Impurities . 18
B.2 Production . 18
B.2.1 General . 18
B.2.2 Reforming . 18
B.2.3 Alkaline Electrolysis . 19
B.2.4 Proton exchange membrane (PEM) electrolysis . 19
B.2.5 Byproducts . 19
B.2.6 New production methods . 19
2
---------------------- Page: 4 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
B.3 Transportation . 20
B.3.1 General . 20
B.3.2 Pipeline . 20
B.3.3 Filling centre and tube trailer . 20
B.4 HRS . 21
B.5 Special operations: Commissioning, Maintenance . 21
B.6 Particles . 21
Annex C (informative) Example of Risk Assessment — Centralized production, pipeline
transportation . 22
Bibliography . 30
3
---------------------- Page: 5 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
European foreword
This document (EN 17124:2018) has been prepared by Technical Committee CEN/TC 268 “Cryogenic
vessels and specific hydrogen technologies applications”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2019, and conflicting national standards shall be
withdrawn at the latest by April 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
the United Kingdom.
4
---------------------- Page: 6 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
1 Scope
This document specifies the quality characteristics of hydrogen fuel and the corresponding quality
assurance in order to ensure uniformity of the hydrogen product as dispensed for utilization in proton
exchange membrane (PEM) fuel cell road vehicle systems.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
constituent
component (or compound) found within a hydrogen fuel mixture
3.2
contaminant
impurity that adversely affects the components within the fuel cell system or the hydrogen storage
system
Note 1 to entry: An adverse effect can be reversible or irreversible.
3.3
detection limit
lowest quantity of a substance that can be distinguished from the absence of that substance with a stated
confidence limit
3.4
determination limit
lowest quantity which can be measured at a given acceptable level of uncertainty
3.5
fuel cell system
power system used for the generation of electricity on a fuel cell vehicle, typically containing the following
subsystems: fuel cell stack, air processing, fuel processing, thermal management and water management
3.6
hydrogen fuel index
fraction or percentage of a fuel mixture that is hydrogen
3.7
irreversible effect
effect which results in a permanent degradation of the fuel cell power system performance that cannot
be restored by practical changes of operational conditions and/or gas composition
5
---------------------- Page: 7 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
3.8
on-site fuel supply
hydrogen fuel supplying system with a hydrogen production system in the same site
3.9
off-site fuel supply
hydrogen fuel supplying system without a hydrogen production system in the same site, receiving
hydrogen fuel which is produced out of the site
3.10
particulate
solid or liquid particle (aerosol) that can be entrained somewhere in the delivery, storage, or transfer of
the hydrogen fuel
3.11
reversible effect
effect which results in a non-permanent degradation of the fuel cell power system performance that can
be restored by practical changes of operational conditions and/or gas composition
4 Requirements
The fuel quality requirements at the dispenser nozzle applicable to the aforementioned grades of
hydrogen fuel for PEM fuel cells in road vehicles shall meet the requirements of Table 1. The fuel
specifications are not process or feedstock specific. Non-listed contaminants have no guarantee of being
benign.
6
---------------------- Page: 8 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Table 1 — Fuel quality specifications for PEM fuel cell road vehicle applications
Constituent Characteristics
a 99,97 %
Hydrogen fuel index (minimum mole fraction)
Total non-hydrogen gases 300 μmol/mol
Maximum concentration of individual contaminants
Water (H O) 5 μmol/mol
2
b 2 μmol/mol
Total hydrocarbons (THC) (Excluding Methane)
Methane (CH ) 100 µmol/mol
4
Oxygen (O ) 5 μmol/mol
2
Helium (He) 300 μmol/mol
Nitrogen (N ) 300 μmol/mol
2
Argon (Ar) 300 μmol/mol
Carbon dioxide (CO ) 2 μmol/mol
2
c 0,2 μmol/mol
Carbon monoxide (CO)
Total sulphur compounds (H S basis) 0,004 μmol/mol
2
c 0,2 μmol/mol
Formaldehyde (HCHO)
c 0,2 μmol/mol
Formic acid (HCOOH)
Ammonia (NH ) 0,1 μmol/mol
3
d 0,05 μmol/mol
Halogenated compounds (Halogenate ion basis)
Maximum particulates concentration 1 mg/kg
For the constituents that are additive, such as total hydrocarbons and total sulphur
compounds, the sum of the constituents shall be less than or equal to the acceptable limit.
a
The hydrogen fuel index is determined by substracting the “total non-hydrogen gases” in this
table, expressed in mole percent, from 100 mol percent.
b
Total hydrocarbons include oxygenated organic species. Total hydrocarbons shall be measured
on a carbon basis (μmolC/mol).
c
Total of CO, HCHO, HCOOH shall not exceed 0,2 µmol/mol
d
All halogenated compounds which could potentially be in the hydrogen gas (for example,
hydrogen chloride (HCl), and organic halides (R-X)) should be determined according to the hydrogen
quality assurance discussed in Clause 6 and the sum shall be less than 0,05 µmol /mol).
5 Hydrogen Quality Control Approaches
5.1 General requirements
Quality verification requirements for the qualification tests shall be performed at the dispenser nozzle
under the applicable standardized sampling and analytical methods where available. Alternatively, the
quality verification requirements may be performed at other locations in accordance with the quality
assurance risk assessment.
7
---------------------- Page: 9 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
There are two kinds of quality control at a Hydrogen Refueling Stations (HRS): on line monitoring or off
line analysis after sampling. These methods can be used individually or together to ensure hydrogen
quality levels.
5.2 Sampling
Spot sampling at an HRS involves capturing a measured amount for chemical analysis. Sampling is used
to perform an accurate and comprehensive analysis of impurities, which is done externally, typically at a
laboratory. Since the sampling process involves drawing a gas sample, it is typically done on a periodic
basis and requires specialized sampling equipment and personnel to operate it. The sampling procedure
shall ensure and maintain the integrity of the sample.
NOTE ISO/TS 19880-1 includes recommendations for sampling procedure.
5.3 Monitoring
An HRS can have real time monitoring of the hydrogen gas stream for one or more impurities on a
continuous or semi-continuous basis. A critical impurity can be monitored to ensure it does not exceed a
critical level, or monitoring of canary species are used to alert of potential issues with the hydrogen
production or purification process. Monitoring equipment is installed in-line with the hydrogen gas
stream and shall meet the process requirements of the HRS, as well as be calibrated on a periodic basis.
6 Hydrogen Quality Assurance Methodology
6.1 General Requirements – Potential sources of impurities
For a given HRS, the contaminants listed in the hydrogen specification referred to Table 1 may or may
not be present. There are several parts of the supply chain where impurities can be introduced. Annex B
describes potential impurities at each step of the supply chain.
When a contaminant is classified as potentially present, it shall be taken into account in the Quality
Assurance methodology (risk assessment or prescriptive approach) described below.
6.2 Prescriptive Approach for Hydrogen Quality Assurance
A prescriptive approach can be applied for clearly identified supply chains. An approach to conducting a
quality analysis of the contaminants listed in Clause 5 is to consider the potential sources of
contaminants, and establish protocol for analysing potential contaminants.
Taking into account all existing hydrogen production methods, hydrogen transportation methods and
non-routine procedures, prescriptive quality assurance plan shall be determined.
6.3 Risk Assessment for Hydrogen and Quality Assurance
Risk assessment consists of identifying the probability of having each impurity above the threshold
values of specifications given in Table 1 and evaluating the severity of each impurity for the fuel cell car.
As an aid to clearly defining the risk(s) for risk assessment purposes, three fundamental questions are
often helpful:
— What might go wrong: which event could cause the impurities to be above the threshold value?
— What is the likelihood (probability of occurrence) that impurities could be above the threshold value?
— What are the consequences (severity) for the fuel cell car?
In doing an effective risk assessment, the robustness of the data set is important because it determines
the quality of the output. Revealing assumptions and reasonable sources of uncertainty will enhance
8
---------------------- Page: 10 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
confidence in this output and/or help identify its limitations. The output of the risk assessment is a
qualitative description of a range of risk. The probability of an occurrence in which each hydrogen
impurity exceeds the threshold value is defined by the following table of occurrence classes:
Table 2 — Occurrence classes for an impurity
Occurrence Class name Occurrence or frequency Occurrence or
class frequency
Very unlikely Contaminant above threshold
0 (Practically never been observed for this type Never
impossible) of source in the industry
Known to occur in the Industry
1 Very rare for the type of source/ Supply 1 per 1 000 000 refueling
chain considered
Has happened more than
2 Rare 1 per 100 000 refueling
once/year in the Industry
Has happened repeatedly for this
3 Possible type of source at a specific 1 out of 10 000 refueling
location
4 Frequent Happens on a regular basis Often
The range of severity level (level of damage for vehicle) is defined in Table 3:
9
---------------------- Page: 11 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Table 3 — Severity levels for an impurity
Severity FCEV Performance impact or damage Impact categories
class
Performance Hardware Hardware
impact impact impact
temporary permanent
— No impact
0 No No No
— Minor impact
1 Yes No No
— Temporary loss of power
— No impact on hardware
— Car still operates
— Reversible damage
2 Yes or No Yes No
— Requires specific light maintenance
procedure
— Car still operates
— Reversible damage
3 Yes Yes No
— Requires specific immediate
maintenance procedure . Gradual
power loss that does not compromise
safety
— Irreversible damage
a Yes Yes Yes or No
4
— Requires major repair (e.g. stack
change)
— Power loss or Car Stop that
compromises safety
a
Any damage, whether permanent ornon-permanent, which compromises safety will be categorized as 4,
otherwise non-permanent damage will be categorized as 1, 2 or 3.
The severity level of each impurity shall be determined. Indeed, the impact on the car if each impurity
exceeds the threshold values given in Table 1 will depend on the concentration of the contaminant. The
following Table 4 shows the summary of the concentration based impact of the impurities on the fuel cell.
In the first two columns the contaminants with their chemical formulas are given. An estimate of the
exceeded concentration above the threshold value for each impurity is named “Level 1” and is given in
column 5. According to this concentration, a severity class is given in column 4 for each impurity. This
severity class covers the impact of this impurity above the threshold value up to this limit.
If higher concentrations that exceed Level 1 can be reached, the Severity Class is given in column 6.
10
---------------------- Page: 12 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Table 4 — Severity Classes (SC) — Impact of impurities on fuel cell powertrain
Impurity Threshold SC for impurity Level 1 SC for impurity
Value [ppm] concentration Value concentration greater
from threshold than Level 1
(Table 1) [ppm]
to level 1
Total non-H2 gases 300 Not applicable 300 4
Nitrogen and N2, Ar 300 Not applicable 300 4
Argon
Oxygen O2 5 No test data No test data Without test data for
available available proposed level 1 value
validation already SC 4
if Threshold exceeded
Carbon dioxide CO2 2 1 3 4
b
Carbon monoxide CO 0,2 2–3 1 4
Methane CH4 100 1 300 4
Water H2O 5 4 NA Already SC 4 if
Threshold exceeded
Total sulphur H2S basis 0,004 4 NA Already SC 4 if
compounds Threshold exceeded
Ammonia NH3 0,1 4 NA Already SC 4 Threshold
exceeded
b
Total CH4 basis 2 1–4 NA Already SC 4 if
hydrocarbons Threshold exceeded
b
Formaldehyde CH2O 0,2 2–3 1 4
b
Formic Acid CH2O2 0,2 2–3 1 4
Total carbon Σ CO, 0,2 2–3 1 4
monoxide, CH2O,
formaldehyde and CH O
2 2
formic acid
Total halogenated 0,05 4 NA Already SC 4 if
compounds Threshold exceeded
Helium He 300 Not applicable 300 4
Maximum 1 mg/kg 4 NA Already SC 4 if
particulates Threshold exceeded
concentration
(liquid and solid)
a
Threshold value according to the requirements in the hydrogen specification.
b
Higher value to be considered for risk assessment approach until more specific data are available.
The final risk is defined by Table 5, titled “Acceptability table”, and which combines both of the above
tables as follows:
11
---------------------- Page: 13 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Table 5 — Acceptability table
Severity
Occurrence 0 1 2 3 4
as the
4
combined
probabilities
3
of
2
occurrence
along the
1
whole supply
0
chain
Further investigations are
Acceptable risk area Unacceptable risk ;
needed: existing barriers
Key Existing controls additionnal control or
or control may not be
acceptable barriers are required
enough
For each impurity of the specification and for a given HRS (including the supply chain of hydrogen), a risk
assessment shall be applied to define the global risk. Risk control includes decision making to reduce
and/or accept risks. The purpose of risk control is to reduce the risk to an acceptable level. The amount
of effort used for risk control should be proportional to the significance of the risk. Decision makers might
use different processes, including a benefit-cost analysis, for understanding the optimal level of risk
control. Risk control might focus on the following questions:
— Is the risk above an acceptable level?
— What can be done to reduce or eliminate risks?
— What is the appropriate balance among benefits, risks and resources?
For each level of risk, decision shall be taken in order to either refuse the risk and then find mitigation or
barriers to reduce it, or accept the risk level as it is. Risk reduction focuses on processes for mitigation or
avoidance of quality risks when it exceeds an acceptable level (yellow or red zone in Table 5). Risk
reduction might include actions taken to mitigate the severity and/or probability of occurrence.
An example of such approach is given in Annex C.
7 Routine Quality Control
Routine analysis is performed on a periodic basis once every specified time period or once for each lot or
batch. The methodology selected in hydrogen quality assurance plan determines the type and frequency
of the routine analysis. A prescriptive methodology may be used as described in 6.2 or a risk assessment
methodology may be used as described in 6.3. Information on the routine analysis for each step of the
supply chain is provided in Annex B.
8 Non-routine Quality Control
The hydrogen quality plan shall identify any non-routine conditions and subsequent required actions.
Some common non-routine conditions include the following:
— a new production system is constructed at a production site or a new HRS is first commissioned;
— the production system at a production site or HRS is modified;
12
---------------------- Page: 14 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
— a routine or non-routine open inspection, repair, catalyst exchange, or the like is performed on a
production system at the production site or HRS;
— a question concerning quality is raised when, for example, there is a problem with a vehicle because
of hydrogen supplied at the production site or HRS, and a claim is received from a user directly or
indirectly;
— an issue concerning quality emerges when, for example, a voluntary audit raises the possibility that
quality control is not administered properly;
— analysis is deemed necessary for testing, research or any other purposes;
— after any severe malfunctions of transportation system of compressed hydrogen, liquid hydrogen
and hydrogen pipeline.
9 Non compliances
In case of quality control showing results not compliant with table under Article 5, proper action shall be
taken by the operator to prevent further out of specification H refuelling of the vehicles.
2
13
---------------------- Page: 15 ----------------------
SIST EN 17124:2018
EN 17124:2018 (E)
Annex A
(informative)
Impact of impurities
A.1 General
The following chapter gives a brief description of the impact of impurities on the stack, fuel cell
components and the complete fuel cell powertrain. Detai
...
SLOVENSKI STANDARD
oSIST prEN 17124:2017
01-julij-2017
Hydrogen fuel - Product specification and Quality assurance - Proton exchange
membrane (PEM) fuel cell applications for road vehicles
Hydrogen fuel - Product specification and Quality assurance - Proton exchange
membrane (PEM) fuel cell applications for road vehicles
Wasserstoff als Kraftstoff - Produktfestlegung - Teil 2: Protonenaustauschmembran
(PEM) - Brennstoffzellenanwendungen für Straßenfahrzeuge
&RPEXVWLEOHjEDVHGK\GURJqQH6SpFLILFDWLRQSURGXLWHWDVVXUDQFHTXDOLWp
$SSOLFDWLRQVXWLOLVDQWGHVSLOHVjFRPEXVWLEOHjPHPEUDQHpFKDQJHXVHGHSURWRQV
3(0SRXUYpKLFXOHVURXWLHUV
Ta slovenski standard je istoveten z: prEN 17124
ICS:
27.075 Tehnologija vodika Hydrogen technologies
oSIST prEN 17124:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 17124:2017
---------------------- Page: 2 ----------------------
oSIST prEN 17124:2017
DRAFT
EUROPEAN STANDARD
prEN 17124
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2017
ICS 27.075; 71.100.20
English Version
Hydrogen fuel - Product specification and quality
assurance - Proton exchange membrane (PEM) fuel cell
applications for road vehicles
Combustible à base d¿hydrogène - Spécification Wasserstoff als Kraftstoff - Produktfestlegung - Teil 2:
produit et assurance qualité - Applications utilisant des Protonenaustauschmembran (PEM) -
piles à combustible à membrane échangeuse de Brennstoffzellenanwendungen für Straßenfahrzeuge
protons (PEM) pour véhicules routiers
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 268.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 17124:2017 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Requirements . 6
5 Hydrogen Quality Control Approaches . 7
5.1 General requirements . 7
5.2 Sampling . 8
5.3 Monitoring . 8
6 Hydrogen Quality Assurance Methodology . 8
6.1 General Requirements – Potential sources of impurities . 8
6.2 Prescriptive Approach for H Quality Assurance . 8
2
6.3 Risk Assessment for H quality Assurance . 8
2
7 Routine Quality Control . 12
8 Non-routine Quality Control . 12
9 Non compliances . 13
Annex A (informative) Impact of impurities . 14
A.1 General . 14
A.2 Inert Gases: Ar, N . 14
2
A.3 Oxygen . 14
A.4 Carbon Dioxide . 14
A.5 Carbon Monoxide . 14
A.6 Methane . 15
A.7 Water . 15
A.8 Total Sulphur compounds . 15
A.9 Ammonia . 15
A.10 Total Hydrocarbons . 15
A.11 Formaldehyde . 16
A.12 Formic Acid . 16
A.13 Halogenated Compounds . 16
A.14 Helium . 16
A.15 Solid and liquid particulates (Aerosols) . 16
Annex B (informative) Example of Supply chain evaluation with regards to potential sources
of impurities . 18
B.1 Potential Sources of Impurities . 18
B.2 Production . 18
B.2.1 General . 18
B.2.2 Reforming . 18
B.2.3 Alkaline Electrolysis. 19
B.2.4 Proton exchange membrane electrolysis . 19
B.2.5 Byproducts . 19
B.2.6 New production methods . 19
B.3 Transportation . 20
2
---------------------- Page: 4 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
B.3.1 General . 20
B.3.2 Pipeline . 20
B.3.3 Filling centre and Tube Trailer . 20
B.4 HRS . 21
B.5 Special operations: Commissionning, Maintenance . 21
B.6 Particulates . 21
Annex C (informative) Example of Risk Assessment — Centralized production, pipeline
transportation . 22
Bibliography . 30
3
---------------------- Page: 5 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
European foreword
This document (prEN 17124:2017) has been prepared by Technical Committee CEN/TC 268 “Cryogenic
vessels and specific hydrogen technologies applications”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
4
---------------------- Page: 6 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
1 Scope
This draft European standard specifies the quality characteristics of hydrogen fuel and the corresponding
quality assurance in order to ensure uniformity of the hydrogen product as dispensed for utilization in
proton exchange membrane (PEM) fuel cell road vehicle systems.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 14687-2:2012, Hydrogen fuel — Product specification — Part 2: Proton exchange membrane (PEM)
fuel cell applications for road vehicles
ISO/TS 19880-1, Gaseous hydrogen — Fuelling stations — Part 1: General requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
constituent
component (or compound) found within a hydrogen fuel mixture
3.2
contaminant
impurity that adversely affects the components within the fuel cell system or the hydrogen storage
system
Note 1 to entry An adverse effect can be reversible or irreversible.
3.3
detection limit
lowest quantity of a substance that can be distinguished from the absence of that substance with a stated
confidence limit
3.4
determination limit
lowest quantity which can be measured at a given acceptable level of uncertainty
3.5
fuel cell system
power system used for the generation of electricity on a fuel cell vehicle, typically containing the following
subsystems: fuel cell stack, air processing, fuel processing, thermal management and water management
3.6
hydrogen fuel index
fraction or percentage of a fuel mixture that is hydrogen
3.7
irreversible effect
effect, which results in a permanent degradation of the fuel cell power system performance that cannot
be restored by practical changes of operational conditions and/or gas composition
5
---------------------- Page: 7 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
3.8
on-site fuel supply
hydrogen fuel supplying system with a hydrogen production system in the same site
3.9
off-site fuel supply
hydrogen fuel supplying system without a hydrogen production system in the same site, receiving
hydrogen fuel which is produced out of the site
3.10
particulate
solid or aerosol particle that can be entrained somewhere in the delivery, storage, or transfer of the
hydrogen fuel
3.11
reversible effect
effect which results in a temporary degradation of the fuel cell power system performance that can be
restored by practical changes of operational conditions and/or gas composition
4 Requirements
The fuel quality requirements at the dispenser nozzle applicable to the aforementioned grades of
hydrogen fuel for PEM fuel cells in road vehicles shall meet the requirements of Table 1. The fuel
specifications are not process or feed stock specific. Non-listed contaminants have no guarantee of being
benign.
6
---------------------- Page: 8 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
Table 1 — Directory of limiting characteristics
Constituent Characteristics
a 99,97 %
Hydrogen fuel index (minimum mole fraction)
Total non-hydrogen gases 300 μmol/mol
Maximum concentration of individual contaminants
Water (H O) 5 μmol/mol
2
b 2 μmol/mol
Total hydrocarbons (Excluding Methane)
Methane (CH ) 100 µmol/mol
4
Oxygen (O ) 5 μmol/mol
2
Helium (He) 300 μmol/mol
Nitrogen (N ) 300 μmol/mol
2
Argon (Ar) 300 μmol/mol
Carbon dioxide (CO ) 2 μmol/mol
2
c 0,2 μmol/mol
Carbon monoxide (CO)
Total sulfur compounds (H S basis) 0,004 μmol/mol
2
c 0,2 μmol/mol
Formaldehyde (HCHO)
c 0,2 μmol/mol
Formic acid (HCOOH)
Ammonia (NH ) 0,1 μmol/mol
3
d 0,05 μmol/mol
Total halogenated compounds (Halogenate ion
basis)
Maximum particulates concentration 1 mg/kg
For the constituents that are additive, such as total hydrocarbons and total sulfur
compounds, the sum of the constituents shall be less than or equal to the acceptable limit.
a
The hydrogen fuel index is determined by substracting the “total non-hydrogen gases” in this
table, expressed in mole percent, from 100 mol percent.
b
Total hydrocarbons include oxygenated organic species. Total hydrocarbons shall be measured
on a carbon basis (μmolC/mol).
c
Total of CO, HCHO, HCOOH shall not exceed 0,2 µmol/mol
d
Total halogenated compounds include, for example, hydrogen chloride (HCl), and organic halides
(R-X). Species will be checked according Quality Assurance.
5 Hydrogen Quality Control Approaches
5.1 General requirements
Quality verification requirements for the qualification tests shall be performed at the dispenser nozzle
under applicable standardized sampling and analytical methods where available. Alternatively, the
7
---------------------- Page: 9 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
quality verification requirements may be performed at other locations or under other methods
acceptable to the supplier and the customer.
There are two kinds of quality control at a HRS: On line monitoring or off line analysis after sampling.
These methods can be used individual or together to ensure hydrogen quality levels.
5.2 Sampling
Spot sampling at a HRS involves capturing a measured amount for chemical analysis. Sampling is used to
perform an accurate and comprehensive analysis of impurities which is done externally, typically at a
laboratory. Since the sampling process involves drawing a sample of gas, it is typically done on a periodic
basis and requires specialized sampling equipment and personnel to operate it. Sampling procedures
shall follow the requirements in ISO/TS 19880-1. Sampling procedure shall ensure and maintain the
integrity of the sample.
5.3 Monitoring
A HRS can have real time monitoring of the hydrogen gas stream for one or more impurities on a
continuous or semi-continuous basis. A critical impurity can be monitored to ensure it does not exceed a
critical level, or monitoring of canary species are used to alert of potential issues with the hydrogen
production or purification process. Monitoring equipment is installed in-line with the hydrogen gas
stream and shall meet the process requirements of the HRS, as well as be calibrated on a periodic basis.
6 Hydrogen Quality Assurance Methodology
6.1 General Requirements – Potential sources of impurities
For a given HRS, the contaminants listed in the hydrogen specification referred to Clause 4 may or may
not be potentially present. There are several parts of the supply chain where impurities can be
introduced. The potential impurities in each step of the supply chain are described in Annex X.
When a contaminant is classified as potentially present, it shall be taken into account in the Quality
Assurance methodology (risk assessment or prescriptive approach) described at Clause 8.
6.2 Prescriptive Approach for H Quality Assurance
2
A prescriptive approach can be applied for clearly identified supply chains. An approach to conducting a
quality analysis of the contaminants listed in Clause 5 is to consider the potential sources of
contaminants, and establish protocol for analysing potential contaminants.
An example of such approach is given in Annex B.
Prescriptive quality assurance plan shall be determined taking into account all existing hydrogen
production methods, hydrogen transportation methods and non-routine procedures.
6.3 Risk Assessment for H quality Assurance
2
Risk assessment consists of the identification of the probability to have each impurity above the threshold
values of specifications given in Clause 5 and the evaluation of severity of each impurity for the fuel cell
car. As an aid to clearly defining the risk(s) for risk assessment purposes, three fundamental questions
are often helpful:
— What might go wrong: which event can cause the impurities to be above the threshold value?
— What is the likelihood (probability of occurrence) that impurities can be above the threshold value?
— What are the consequences (severity) for the fuel cell car?
8
---------------------- Page: 10 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
In doing an effective risk assessment, the robustness of the data set is important because it determines
the quality of the output. Revealing assumptions and reasonable sources of uncertainty will enhance
confidence in this output and/or help identify its limitations. The output of the risk assessment is a
qualitative description of a range of risk. For the probability of occurrence of the event: impurities in
hydrogen exceed the threshold value, the following table of occurrence classes has been defined:
Table 2 — Occurrence classes for an impurity
Occurrence Class name Occurrence or frequency Occurrence or
class frequency
Very unlikely Contaminant above threshold
0 (Practically never been onserved for this Never
impossible) type of source in the industry
Heard in the Industry for the
1 per 1 000 000
1 Very rare type of source/ Supply chain
refueling
considered
Has happened more than
2 Rare 1 per 100 000 refueling
once/year in the Industry
Has happened repeatedly for
3 Possible this type of source at a specific 1 out of 10 000 refueling
location
4 Frequent Happens on a regular basis Often
The range of severity level (level of damage for vehicle) is defined by the following table:
9
---------------------- Page: 11 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
Table 3 — Severity levels for an impurity
Severity FCEV Performance impact or damage Impact categories
class
Performan Hardware Hardware
ce impact impact impact
temporary permanent
0 — No impact No No No
1 — Minor impact Yes No No
— Temporary loss of power
— No impact on hardware
— Car still operates
2 — Reversible damage Yes or No Yes No
— Requires specific procedure, light
maintenance
— Car still operates
3 — Reversible damage Yes Yes No
— Requires specific procedure and
immediate maintenance. Gradual
power loss that does not compromises
safety
4 — Irreversible damage Yes Yes a
Yes or No
— Requires major repair (e.g. stack
change)
— Power loss or Car Stop that
compromises safety
a
Any damage, whether permanent or temporary, which compromises safety will be categorized as 4,
otherwise temporary damage will be categorized as 1, 2 or 3.
The following Table 4 Severity Classes shows the summary of the concentration based impact of the
impurities on the fuel cell. In the first two columns the contaminants with their chemical formulas are
given. The third column gives an indication of the severity class up to the Limiting characteristics
threshold value which is given in column four. The column six gives the Level 1 Value needed for the risk
assessment approach to define the quality assurance. The columns five and seven indicate the severity
classes for the concentration ranges from ISO 14687-2:2012 threshold value up to Level 1 Value and from
Level 1 Value to infinity.
10
---------------------- Page: 12 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
Table 4 — Severity Classes — Impact of impurities on fuel cell powertrain
Impurity SC for 0 ppm ISO 14687 SC for Level 1 SC for
Value
≤ Concentration Threshold Value ≤ Concentr Level 1
< ISO Value Value [ppm] ation < Level 1 [ppm] Value ≤ Concentration
Value ≤ 100 %
Total non-H2 gases 0 300 Not applicable 300 4
Total Nitrogen and N2, Ar 0 300 Not applicable 300 4
Argon
Oxygen O2 0 5 No test data No test data Without test data for
available available proposed level 1 value
validation already SC 4
if Threshold exceeded
Carbon dioxide CO2 0 2 1 3 4
b
Carbon monoxide CO 0–2 0,2 2–3 1 4
Methane CH 0 100 1 300 4
4
Water H2O 0 5 4 NA Already SC 4 if
Threshold exceeded
Total sulfur H2S basis 0–4 0,004 4 NA Already SC 4 if
compounds Threshold exceeded
Ammonia NH3 0 0,1 4 NA Already SC 4 Threshold
exceeded
b
Total CH basis 0–4 2 1–4 NA Already SC 4 if
4
hydrocarbons Threshold exceeded
b
Formaldehyde CH O 0–2 0,2 2–3 1 4
2
b
Formic Acid CH2O2 0–2 0,2 2–3 1 4
Total carbon Σ CO, 0–2 0,2 2–3 1 4
monoxide, CH2O,
formaldehyde and CH O
2 2
formic acid
Total halogenated 0–4 0,05 4 NA Already SC 4 if
compounds Threshold exceeded
Helium He 0 300 Not applicable 300 4
Maximum 0–4 1 mg/kg 4 NA Already SC 4 if
particulates Threshold exceeded
concentration
(liquid and solid)
a
Threshold value according to hydrogen specification. Requirements
b
Higher value to be considered for risk assessment approach until more specific data are available.
11
---------------------- Page: 13 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
The final risk is defined by the acceptability table build by combination of both above tables as follows:
Table 5 — Acceptability table
Severity
0 1 2 3 4
Occurrence As
4
the combined
probabilities
3
of occurrence
2
along the
whole supply
1
chain
0
Unacceptable risk ; Further investigations are
Acceptable risk area Existing
Key additionnal control or needed: existing barriers or
controls acceptable
barriers are required control may not be enough
For each impurity of the specification and for a given HRS (including the supply chain of hydrogen), a risk
assessment shall be applied to define the global risk. Risk control includes decision making to reduce
and/or accept risks. The purpose of risk control is to reduce the risk to an acceptable level. The amount
of effort used for risk control should be proportional to the significance of the risk. Decision makers might
use different processes, including benefit-cost analysis, for understanding the optimal level of risk
control. Risk control might focus on the following questions:
— Is the risk above an acceptable level?
— What can be done to reduce or eliminate risks?
— What is the appropriate balance among benefits, risks and resources?
For each level of risk, decision shall be taken in order to either refuse the risk and then find mitigation or
barriers to reduce it, or accept the risk level as it is. Risk reduction focuses on processes for mitigation or
avoidance of quality risk when it exceeds an acceptable level (yellow or red zone in 9). Risk reduction
might include actions taken to mitigate the severity and/or probability of occurrence.
7 Routine Quality Control
Routine analysis is performed on a periodic basis once every specified time period or once for each lot or
batch. The methodology selected in hydrogen quality assurance plan determines the type and frequency
of the routine analysis. A prescriptive methodology may be used as described in 6.2 or a risk assessment
methodology may be used as described in 6.3. Information on the routine analysis for each step of the
supply chain is provided in Annex Y.
8 Non-routine Quality Control
The hydrogen quality plan shall identify any non-routine conditions and subsequent required actions.
Some common non-routine conditions include the following:
— a new production system is constructed at a production site or a new HRS is first commissioned;
— the production system at a production site or HRS is modified;
12
---------------------- Page: 14 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
— a routine or non-routine open inspection, repair, catalyst exchange, or the like is performed on a
production system at the production site or HRS;
— a question concerning quality is raised when, for example, there is a problem with a vehicle because
of hydrogen supplied at the production site or HRS, and a claim is received from a user directly or
indirectly;
— an issue concerning quality emerges when, for example, a voluntary audit raises the possibility that
quality control is not administered properly;or
— analysis is deemed necessary for testing, research or any other purposes;
— after any severe malfunctions of transportation system of compressed hydrogen, liquid hydrogen
and hydrogen pipeline
9 Non compliances
In case of quality control showing results not compliant with table under Article 5, proper action shall be
taken by the operator to prevent further refueling with out of specification H to the vehicles.
2
13
---------------------- Page: 15 ----------------------
oSIST prEN 17124:2017
prEN 17124:2017 (E)
Annex A
(informative)
Impact of impurities
A.1 General
The following chapter gives a brief description of the impact of impurities on the stack, fuel cell
components and the complete fuel cell powertrain. Detailed information can be found in the relevant
literature and journal publications. It has to be noted that Annex A refers to known impurities and their
effects on the fuel cell powertrain at the time of publication. It cannot be excluded that further impurities
exists. Furthermore in most cases only the impact of a single impurity has been investigated and there is
still the need for fundamental research regarding the impact of a combination of the different impurities
on the fuel cell power train.
A.2 Inert Gases: Ar, N
2
The main effect due to the presence of inert gases such as argon (Ar) and nitrogen (
...
Questions, Comments and Discussion