Petroleum products - Determination and application of precision data in relation to methods of test

Produits pétroliers — Détermination et application des valeurs de fidélité relatives aux méthodes d'essai

General Information

Status
Withdrawn
Publication Date
31-Oct-1979
Withdrawal Date
31-Oct-1979
Current Stage
9599 - Withdrawal of International Standard
Start Date
17-Dec-1992
Completion Date
13-Dec-2025
Ref Project

Relations

Standard
ISO 4259:1979 - Petroleum products -- Determination and application of precision data in relation to methods of test
English language
27 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4259:1979 - Petroleum products — Determination and application of precision data in relation to methods of test Released:11/1/1979
French language
27 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 4259:1979 is a standard published by the International Organization for Standardization (ISO). Its full title is "Petroleum products - Determination and application of precision data in relation to methods of test". This standard covers: Petroleum products - Determination and application of precision data in relation to methods of test

Petroleum products - Determination and application of precision data in relation to methods of test

ISO 4259:1979 is classified under the following ICS (International Classification for Standards) categories: 75.080 - Petroleum products in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 4259:1979 has the following relationships with other standards: It is inter standard links to SIST ISO 4259:1996, ISO 4259:1992. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase ISO 4259:1979 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.

Standards Content (Sample)


International Standard @ 4259
INTERNATIONAL ORGANIZATION FOR STANDARDIZATIONOME~YHAPOAHAR OPïAHH3AUHR il0 CTAHAAPTH3AUHH«)RGANISATION INTERNATIONALE DE NORMALISATION
Petroleum products - Determination and application of
precision data h relation to methods of test
Produits pétroliers - Détermination et application des valeurs de fidélité relatives aux méthodes d'essai
First edition - 1979-11-15
I
- UDC 666.7:519.23:620.1 Ref. No. IS0 4259-1979 (E)
E
R
Descriptors : petroleum products, test results, reliability, statistical analysis, definitions
z
O
(1
Price based on 27 pages
FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 member bodies). The work of developing
International Standards is carried out through IS0 technical committees. Every
member body interested in a subject for which a technical committee has been set
up has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated
to the member bodies for approval before their acceptance as International
Standards by the IS0 Council.
i
International Standard IS0 4259 was developed by Technical Committee
lSO/TC 28, Petroleum products and lubricants, and was circulated to the member
bodies in April 1977.
I
It has been approved by the member bodies of the following countries :
Australia Hungary Romania
Austria India South Africa, Rep. of
Brazil Iran Spain
Bulgaria Israel Turkey
Canada Italy United Kingdom
Finland Japan USA
France Poland USSR
Germany, F.R. Portugal
The member body of the following country expressed disapproval of the document
on technical grounds :
Sweden
0 International organization for Standardization, 1979
Printed in Switzerland
INTERNATIONAL STANDARD IS0 4259-1 979 (E)/ER RATUM
Published 1981-01-15
INTERNATIONAL ORGANIZ4TION FOR STANDARDIZATION .MEXLlYHAPOAHAR OPTAHM3AUMR il0 CTAHLlAPTH3AUMM .ORGANISATION INTERNATIONALE DE NORMALISATION
Petroleum products - Determination and application of precision data in relation to methods of test
ERRATUM
Page 1
In clause 1, paragraph 2, line 2, replace "tests" by "test".
Page 4
In subclause 4.1, paragraph 3, line 3, replace "weighed" by "weighted".
Page 6
In sub-clause 4.3, paragraph 2, line 3, replace "If" by "It"
Page 7
In sub-clause 5.1.2, formula (41, replace "SS," by "S'S, ".
In sub-clause 5.2, line 4, add "at" after "out",
Page 17
S L
jt In clause C.3, in the expression for "Mi2", replace " " by " ".

CONTENTS Page
O Introduction . 1
1 Scope and field of application . 1
2 Definitions., . 1
3 Stages in planning of an inter-laboratory test programme for the determi-
nation of the precision of a test method .
a draft method of test . 3
3.1 Preparing
Planning a pilot programme with at least two laboratories . 3
3.2
3.3 Planning the inter-laboratory programme . 3
3.4 Executing the inter-laboratory programme . 3
4 Inspection of inter-laboratory results for uniformity and for outliers . 3
4.0 Introduction . 3
4.1 Transformation of data . 4
4.2 Tests for outliers . 4
4.3 Rejection of complete data from a sample . 6
5 Analysis of variance and calculation of precision estimates . 6
5.0 Introduction . 6
5.1 Estimating missing or rejected values . 6
5.2 Rejection test for outlying laboratories . 7
5.3 AnalysiS of variance . 7
5.4 Expectation of mean square and calculation of precision estimates . 9
5.5 Precision clause of a method of test . 10
6 Significance of repeatability r and reproducibility R as discussed in earlier
clauses . 10
6.0 Introduction . 10
6.1 Repeatability r . 10
6.2 Reproducibility R . 11
7 Specifications . 12
7.1 Aim of specifications . 12
7.2 Construction of specifications . 12

8 Quality control against specifications . . 12
8.0 Introduction .
. 12
8.1 Testing margin at the supplier's .
. 12
8.2 Testing margin at the recipient's .
. 13
9 Acceptance and rejection rules in case of dispute . . 13
Annexes
A Determination of number of samples required .
. 14
B Derivation of formula for calculating the number of samples required .
. 15
C Notation and tests .
. 16
D Example of procedure for inspection of results of test for determinatiot f
bromine number .
. 19
E Types of dependence and corresponding transformations .
.22
F Univariate regression analysis .
.23
G Rules for rounding off results . .26
H Explanation of formulae in 6.1.2 and 6.2.2 . .27
Bibliography .
.27
iii
~~
INTERNATIONAL STANDARD
IS0 4259-1979 (E)
Petroleum products - Determination and application of
precision data in relation to methods of test
O INTRODUCTION usually wider than when the same number of tests are
carried out by a single laboratory, and there is some
For purposes of quality control and to check compliance
variation between means obtained by different laboratories.
with specifications, the properties of commercial petroleum
These give rise to the between-laboratory variance which is
products are assessed by standard laboratory test methods.
that component of the overall variance due to the
Two or more measurements of the same property of a
difference in the mean values obtained by different
specific sample by any given test method do not usually
laboratories. (There is a corresponding definition for
give exactly the same result. It is therefore necessary to
between-operator variance.)
take proper account of this fact, by arriving at statistically
based estimates of the precision for a method, i.e. an
objective measure of the degree of agreement to be
2.3 bias : The difference between the true value (related
expected between two or more results obtained in specified
to the method of test) (see 2.24) and the known value (see
circumstances.
2.81, where this is available.
2.4 blind coding : The assignment of a different number
1 SCOPE AND FIELD OF APPLICATION to each sample but not to repeats. No other identification
or information on any sample is given to the operator,
This International Standard covers the calculation of
precision estimates and their application to specifications.
In particular, it contains definitions of relevant statistical
2.5 check sample : A sample taken at the place where the
terms (clause2), the procedures to be adopted in the
is exchanged, i.e. where the responsibility for the
product
planning of an inter-laboratory test programme to
product quality passes from the supplier to the recipient.
determine the precision of a test method (clause 3), the
method of calculating the precision from the results of such
a programme (clauses 4 and 51, and the procedure to be
2.6 degrees of freedom: The divisor used in the
followed in the interpretation of laboratory results in
calculation of variance; one less than the number of
relation both to precision of the methods and to the limits
independent results.
laid down in specifications (clauses 6 to 9).
NOTE - The definition applies strictly only in the simplest cases.
It must be emphasised that the procedures in this Inter-
Complete definitions are beyond the scope of this International
Standard.
national Standard are designed to cover methods of tests
for petroleum products only. The latter are, in general,
homogeneous products with which serious sampling
problems do not normally arise. It would not be 2.7 determination : The process of carrying out the series
appropriate, therefore, to consider the procedures to be of operations specified in the test method, whereby a single
necessarily of wider application, for example to
value is obtained.
heterogeneous solids.
2.8 known value : The actual quantitative value implied
by the preparation of the sample.
2 DEFINITIONS
NOTE - The known value does not always exist, for example for
For the purposes of this International Standard, the follow
empirical tests such as flash point.
ing definitions apply :
2.1 analysis of variance: A technique which enables the
2.9 mean; arithmetic mean; average: For a given set of
total variance of a method to be broken down into its
results, the sum of the results divided by their number.
component factors.
2.2 between-laboratory variance : When results obtained
2.10 mean square: The sum of squares divided by the
by more than one laboratory are compared, the scatter is
degrees of freedom.
IS0 4259-1979 (E)
2.1 1 normal distribution : The probability distribution of
a continuous random variable X such that, if x is any real
number, the probability density is
(1)
f(K
-m NOTE - p is the true value and U is the standard deviation of the
normal distribution (U > O).
b) Quanti atively
2.12 operator: A person who normally and regularly
carries out a particular test.
The value equal to or below which the absolute
difference etween two single test results on identical
I
material obtained by operators in different laboratories,
2.13 outlier : A result far enough in magnitude from other
using the sjandardized test method, may be expected to
results to be considered not a part of the set.
lie with a pecified probability; in the absence of other
indication, ;the probability level is 95 %.
2.14 precision : The closeness of agreement between the
2.20 result : The final value obtained by following the
results obtained by applying the experimental procedure
complete set f instructions in the test method; it may be
several times on identical materials and under prescribed
obtained from O a single determination of from several deter-
conditions. The smaller the random part of the experimen-
the instructions in the method. (it
tal error, the more precise is the procedure.
all the results are rounded off according to
in annex G.)
2.15 random error : The chance variation encountered in
all test work despite the closest control of variables.
2.21 standard deviation : A measure of the dispersion of a
series of results around their mean, equal to the positive
2.16 recipient : Any individual or organization who
square root O the variance and estimated by the positive
receives or accepts the product delivered by the supplier.
square root of the mean square.
f
2.17 repeatability :
a) Qualitatively
2.23 supplie : Any individual or organization responsible
The closeness of agreement between successive results T‘
for the quality of a product just before it is taken over by
obtained in the normal and correct operation of the
the recipient. ~
same method on identical test material, under the same
conditions (same operator, same apparatus, same
2.24 true value : For practical purposes, the value towards
laboratory, and short intervals of time).
which the ave age of single results obtained by n laboratories
NOTE - The representative parameters of the dispersion of the tends, as n te 1 ds towards infinity; consequently, such a true
population which may be associated with the results are
value is associ ted with the particular method of test.
qualified by the term “repeatability”, for example repeatability
b
standard deviation, repeatability variance.
NOTE - A difffrent and idealized definition is given in IS0 3534,
Statistics - Vocabulary and symbols.
b) Quantitatively
The value equal to or below which the absolute
test results obtained in the
difference between two single
above conditions may be expected to lie with a specified
probability; in the absence of other indication, the
probability level is 95 %.
METHOD
2.18 replication : The execution of a test method more
The stages it? planning an inter-laboratory test programme
than once so as to improve precision and to obtain a closer
are as folfows :
estimation of sampling error. Replication should be
distinguished from repetition in that the former implies
a) Prepar ng a draft method of test.
that experiments are carried out at one place and, as far as
b) Planni I g a pilot programme with two laboratories.
possible, one period of time.
IS0 4259-1979 (E)
c) Planning the inter-laboratory programme. 3.4 Executing the inter-laboratory programme
d) Executing the inter-laboratory programme. One person shall be responsible for the entire programme,
from the distribution of the texts and samples, to the final
The four stages are described in turn.
appraisal of the results. He shall be familiar with the
method, but shall not personally take part in the tests.
3.1 Preparing a draft method of test
The text of the method shall be distributed to all the labo-
This shall contain all the necessary details for carrying out
ratories in time to raise any queries before the tests begin.
the test and reporting the results. Any condition which
If any laboratory wants to practice the method in advance,
could alter the results shall be specified.
this shall be done with samples other than those used in the
programme.
The clause on precision will be included at this stage only
as a heading. The samples shall be accumulated, subdivided and
distributed by the organizer, who shall also keep a reserve
of each sample for emergencies. It is most important that
3.2 Planning a pilot programme with at least two
the individual laboratory portions be homogeneous. They
laboratories
shall be blindcoded before distribution, and the following
A pilot programme is necessary for the following reasons :
instructions shall be sent with them :
a) to verify the details in the operation of the test;
a) the agreed draft method of test;
b) to find out how well operators can follow the
b) the handling and storing requirements for the
instructions of the method;
samples;
c) the order in which the samples are to be tested (a
c) to check the precautions regarding samples;
different random order for each laboratory);
d) to estimate roughly the precision of the test.
d) the statement that two results are to be obtained
At least two samples are required, covering the range of
consecutively on each sample by the same operator with
results to which the test is intended to apply; however, at
the same apparatus;
least 12 laboratory/sample combinations should be
e) the period of time during which all the samples are
included. Each sample is tested twice by each laboratory
to be tested;
under repeatability conditions. If any omissions or
inaccuracies in the draft method are revealed, they shall
a form for reporting the results. For each sample,
f)
now be corrected. The results shall be analysed for bias and
there shall be space for the date of testing, the two
precision : if either is considered to be too large, then
results, and any unusual occurrences. The unit of
alterations to the method shall be considered.
accuracy for reporting the results shall be specified;
g) a statement that the test shall be carried out under
3.3 Planning the inter-laboratory programme
normal conditions, using operators with good experience
There shall be at least five participating laboratories, but it but not exceptional knowledge; and that the duration of
is preferable to exceed this number in order to reduce the the test shall be the same as normal.
number of samples required.
NOTE - The pilot programme operators may take part in the
inter-laboratory programme. If their extra experience in testing
The number of samples shall be sufficient to cover the
a few more samples produces a noticeable effect, it should serve
give reliability to
range of the property measured, and to
as a warning that the method is not satisfactory. They should be
the precision estimates. If any variation of precision with
identified in the report of the results SO that any effect may be
noted.
level was observed in the results of the pilot programme,
then at least five samples shall be used in the inter-
laboratory programme. In any case, it is advisable to aim
4 INSPECTION OF INTER-LABORATORY RESULTS
for 30 degrees of freedom in both repeatability and repro-
FOR UNIFORMITY AND FOR OUTLIERS
ducibility. For repeatability, this means obtaining a total
of 30 pairs of results in the programme. For reproducibility,
4.0 Introduction
table 11 (annex A) gives the number of samples required in
This clause specifies procedures for examining the results
terms of L, P and O, where L is the number of participating
reported in a statistically designed inter-laboratory
laboratories and P and O are the ratios of variance
programme (see clause 3) to establish
component estimates obtained from the pilot programme.
a) the independence of precision,
Specifically, P is the ratio of the interaction component to
the repeatscomponent, and 0 is the ratio of the laboratories
b) the level of the results,
component to the repeats component. Annex B gives the
c) the uniformity of precision from laboratory to
derivation of the formula used. If O is much larger than P,
laboratory,
then 30 degrees of freedom cannot be achieved; the blank
and to detect the presence of outliers. The procedures are
entries in table 11 correspond to this situation or the
described in mathematical terms based on the notation of
approach of it (i.e. when more than 20 samples are
annex C and illustrated with reference to the example of
required). For these cases, there is likely to be a significant
calculation of the bromine number set out in annex D.
bias between laboratories.
IS0 4259-1979 (E)
Throughout this clause (and clause 5), the procedures to be After selecting a transformation on the basis of the depen-
m, it shall be verified that the same trans-
used are first specified and then illustrated by a worked dence of D on
D.
exarnple using data given in annex
It is assumed throughout this clause that all the results are
either from a single normal distribution or capable of being
transformed into such a distribution (see 4.1). Other cases
(which are rare) would require different treatment which is
4.1 .I Worked example
beyond the scope of this International Standard.
Table 1 lists the ~ values of m, D, and d for the eight samples
in the example given in annex D.
4.1 Transformation of data
Inspection of he figures in table 1 shows than both D and
In many test methods the precision depends on the level
1'
d increase witp m, the rate of increase diminishing as m
of the test result, and thus the variability of the reported
increases. A plot of these figures on log-log paper (i.e. a
results is different from sample to sample. The method of
graph of log and log d against log m) shows that the
analysis outlined in this International Standard requires
points may re,asonably 1 be considered as lying about two
that this should not be so and the position is rectified, if
straight lines ('see the figure in annex F). The gradients of
necessary, by a transformation.
these lines are 0,64 and 0,58 respectively and thus, bearing
The laboratories standard deviations Di, (see annex C,
in mind the e rors in these estimated gradients, they may
t
clause C.3) are calculated and plotted against the sample
for convenience be considered as parallel lines with
means mi. If the points so plotted may be considered as
gradient 213. ~
lying about a line parallel to the m-axis, then no trans-
transformation is appropriate both for
formation is necessary. If, however, the plotted points lie
reproducibility, and is given by the
about a curve of the form D = f(m), then a transformation
formula
will be necessary.
The relationship D = f(m) is best established by the
technique of univariate regression analysis (strictly speaking,
Since the constant multiplier may be ignored, the trans-
an iteratively weighed regression should be used, but in
formation thus reduces to that of taking the cube roots
most cases an unweighted regression gives a satisfactory
results (bromine numbers). This yields
approximation).
data shown in table 16 (annex D), in
An outline of the calculation necessary is given in annex F, roots are quoted correct to three decimal
places.
but it is a standard programme for most computers.
Normally, a 5 % significance level will be used to test
whether a regression coefficient differs from zero.
If it has been shown that there is a significantly non-zero
regression coefficient giving a dependence of the form
D = f(m), then the appropriate transformation y = F(x),
where x is the reported result, is given by the formula
shall be inspekted for outliers. These are the values which
are so differdnt from the remainder that it can only be
concluded th t they have arisen from some fault in the
. . . (2)
application of the method or from testing a wrong sample.
t
Many possible tests may be used and the associated signifi-
where k is constant.
cance levels haried, but those that are specified in the
following sub-clauses I have been found to be appropriate
The particular cases likely to be encountered, together with
in this lnterndtional Standard.
the required transformations, are listed in table 20
(annex E). A regression of log D- on log mi will show I
4.2.1 Uniforhity of repeatability
any dependence of the form D =Amb.
The first O tlier test is concerned with detecting a
The choice of transformation is difficult to make the
discordant re ult in a pair of repeat results. This test[']
subject of formalized rules and qualified statistical assistance
involves calcylating i the e$ over all the laboratoryhample
may be required in particular cases.
TABLE 1 ~
Samplenumber 1 3 1 2
m 10,756 I 1,22 I 2.15 I 3,64 110.9 11 48.2 I 65,4 I114
I -
D [ 0,067 10,159 I 0,729 1 0,211 I 0,291 1 [ 150 1 2,22 I 2,93
d I0.050 O 10.057 2 I 0,127 I 0,115 I 0,094 3 I 0,527 I 0,817 I 0,935
~
IS0 4259-1979 (E)
combinations. Cochran‘s criterion at the 1 % level is then range of Dixon r tests’’] is appropriate. This involves form-
used to test the ratio of the largest of these values over ing for each sample, and finally for the laboratory totals
their sum (see annex C, clause C.4). If its value exceeds the (see 5.2), ratios of various differences between the pair
value given in table 17 (annex D), corresponding to the sums aij (see annex C, clause C.5).
1 % probability level, k being the number of pairs available
The appropriate ratio shall be compared with the critical
for comparison, then the member of the pair farthest from
1 % values given in table 18 (annex D), with the value of n
the sample mean shall be rejected and the process repeated,
determined by the number of laboratories concerned. If
reducing k by 1, until no more rejections are called for.
significant value is encountered for individual samples, the
In certain cases, this test ”snowballs” and leads to an un-
corresponding extreme values shall be omitted and the
acceptably large proportion of rejections, (say more than
process repeated. If any extreme values are found in the
10%). If this is so, this rejection test shall be abandoned
laboratory totals, then all the results from this laboratory
and some or all of the rejected results shall be retained. An
shall be rejected.
arbitrary decision based on judgement will be necessary
in this case.
4.2.2 Worked example
4.2.3.1 WORKED EXAMPLE
In the case of the example given in annex D, the difference
0 The application of Dixon‘s test to sample 1 is shown in
between transformed repeat results, i.e. of the pairs of
numbers in table 16, in units of the third decimal place,
detail below. (See note.)
are shown in table 2.
The first step is to place the pair sums for each laboratory
which tested sample 1 in ascending order of magnitude, as
TABLE 2
shown in table 3.
La bora t o r y
1 2
The appropriate Dixon ratio for nine laboratories is rl 1.
-
42 21
For testing the highest value,
23 12
O 6 7 O
- 3,188 - 2,562
14 6 O 32
4 14 r1 ’ - 3,188 - 2,409
65 28
23 20 20
O
= 0,804
62 4 O
44 20 44 O 27 32
This value is greater than the tabulated value and so the
O 59 40 O 30 26 O
- - -
results from laboratory D on this sample are rejected.
The largest
range is 0,078 for laboratory G on sample f
As there has been a rejection, the procedure is repeated for
The sum of squares of all the ranges is
high values without the results for laboratory D being taken
into account. This gives
0.042’ + 0.021’ + . + 0,026’ f O’ = 0.043 9
- 2,562 - 2,540
Thus, the ratio to be compared with the Cochran‘s criterion
r’ ’ - 2,562 - 2,409
is
= 0,144
0,078’
--
- 0,138
0,043 9 Comparison of this value with the corresponding value in
table 18 (annex D), for eight laboratories shows that it is
There are 72 ranges and, as from table 17 (annex D), the
not significant and so there are no further outliers.
criterion for 75 ranges is 0,180 9, this ratio is not significant.
For testing the lowest value,
4.2.3 Uniformity of reproducibility
- 2,409 - 2,409
r’ ’ - 2,562 - 2,409
The remaining outlier tests are concerned with establishing
uniformity in the reproducibility estimate, and are designed
=O
to detect either a discordant pair of results from a laboratory
on a particular sample or a discordant set of results from a This value is compared with the corresponding value in
laboratory on all samples. For both purposes, one of the
table 18 (annex D), namely 0,677.
TABLE 3
Laboratory BI FI CI HI El A IG I J ID
Pair sum 12,409 12,409 12,432 12,476 12,497 12,520 12,540 12,562 13,188
IS0 4259-1979 (E)
others, which are close together lying between 3,85 and
As the calculated value is less than the one in table 18,
5,lO. and so should be rejected. It is noted that the size
there are no outliers at the low end.
of the repeats standard deviation in this sample also tends
This procedure is repeated for each sample. In this example
to confirm it as an outlier.
there were no further significant ratios, and so the only
rejections made were those for sample 1 obtained by
laboratory D.
NOTE - If the two lowest values or the two highest values are
equal, there can be no corresponding outlier.
5 ANALYSIS OF VARIANCE AND CALCULATION
OF PRECISION ESTIMATES
4.3 Rejection of complete data from a sample
5.0 Introduction
The laboratories standard deviation and repeats standard
deviation shall be examined for any outlying samples. If a
After the data have been inspected for uniformity, a trans-
transformation has been carried out or any rejection made,
formation has been performed if necessary, and any outliers
new standard deviations shall be calculated.
have been rejected (see clause 4), an analysis shall be carried
out. First the missing values shall be estimated by the least
If the standard deviation for any sample is excessively
squares method, then an analysis of variance table
large, it shall be examined with a view to rejecting the
constructed, and finally the precision estimates derived.
results from that sample. If is not possible to give an exact
criterion for defining "excessively large" in this context,
but it is felt that this action should be taken only in
5.1 Estimating missing or rejected values
extreme cases1 ).
5.1 .I One of the two repeat values missing or rejected
NOTE - At this stage it is desirable to check that the rejections
carried out have not invalidated the transformation used. If
if one of a pair of repeats (yijl or yijz) is missing or
necessary, the procedure from 4.1 should be repeated with the
outliers deleted.
rejected, this shall be considered to have the same value as
the other repeat in accordance with the least squares
method.
4.3.1 Worked example
The laboratories standard deviations of the transformed
5.1.2 Both repeat values missing or rejected
results, after the rejection of the pair of results by
If both the repeat values are missing, estimates of aij
laboratory D on sample ,I, are given in table 4 in ascending
(= yij, + yij2) shall be made by forming the laboratories x
order of sample mean.
samples interaction sum of squares, including the missing
Inspections shows that there is no outlying sample amongst
values of the totals of the iaboratories/samples pairs of
these. It will be noted that the laboratories standard
results as unknown variables. Any laboratory from which
deviations are now independent of the sample means,
all the results were rejected by Dixon's test shall be ignored
which was the purpose of transforming the results. It was
and the new value of L used. The estimates of the missing
not considered necessary in this case to repeat the
or rejected values shall then be found by forming the partial
calculations with the outlier deleted.
derivatives of this sum of squares with respect to each
variable in turn and equating these to zero to solve as a set
The figures in table 5, taken from a test programme on
of simultaneous equations.
bromine numbers over 100, will illustrate the case of a
sample rejection.
Formula (4) may be used where only one pair sum has to
It is clear, by inspection, that the laboratories standard be estimated. If more estimates are to be made, see, for
deviation of sample 93 at 15,26 is far greater than the instance, reference [5] for details.
TABLE 4
1 4 5 6 2 7
Sample number 3 8
Sample mean 0,910 1 1,066 1,240 1,538 2,217 3,639 4,028 4,851
0.027 8 0.047 4 0.035 7 0.029 7 0,019 6 0.037 8 0.044 8 0,041 6
Laboratories standard deviation
93 92 91 94 95 96
Sample number 90 89
Sample mean 96,l 99,8 119,3 125.4 126,O 139,l 139,4 159,5
Laboratories standard deviation 5,lO 4,20 15,26 4,40 4 ,O9 4,87 4,74 3,85
0,91 0,73 1,32 1,12 1,36
Repeats standard deviation 1 ,I3 0,99 2.97
A test which may prove to be appropriate, but of which no experience is available in this context, is that which involves the ratio gf the
1)
maximum to the minimum of a set of variances (at the 1 % level), as described in Biometrika tables forstatisticjam, volume 1, table 31.
IS0 4259-1979 (E)
If the value of one pair sum a, has to be estimated, the
Table 7 summarizes the calculated Dixon ratios.
estimate is given by the formula
TABLE 7
I
a. =
I Ratio I rql I
(LL, + SS, - TI
...
(4)
Il
(L - 1) 6'- 1)
Low I 0,282
High 1 0,095 I
where
S' = S - number of samples rejected in 4.3
Comparison with the value tabulated in table 18 (annex D)
shows that neither of these ratios is significant and therefore
is the total of remaining pairs in the ith laboratory;
L,
no complete laboratory rejections are necessary.
is the total of remaining pairs in thejth sample;
SI
5.3 Analysis of variance
is the total of all pairs except aji.
T,
5.3.1 Forming the sums of squares for the laboratories x
samples interaction sum of squares
5.1.2.1 WORKED EXAMPLE
The two results from laboratory Don sample 1 were rejected The estimated values, if any, shall be put in the array and
(see 4.2) and thus a4 has to be estimated. an approximate analysis of variance performed.
Total of remaining results in laboratory 4 = 36,354 Mean correction
M = P/2L'S' . . . (5)
Total of remaining results in sample 1 = 19,845
where L' = L - number of laboratories rejected in 5.2.
Total of all the results except a4 = 348,358
Samples sum of squares
AlsoSt=8andL=9.
Hence, the estimate of a4, is given by
. . . (6)
-
[(g X 36,354) + (8 x 19,845) -348.3581
a,J -
(9-1) (8-1)
L/=1 J
Therefore
Laboratories sum of squares
a. = --
'I 56
. . . (7)
5.2 Rejection test for outlying laboratories
Pairs sum of squares
At this stage, one further rejection test remains to be
carried out. This determines whether it is necessary to
reject the complete set of results from any particular
. . (8)
laboratory. It could not be carried out an earlier stage,
L -I
except in the case where no individual results or pairs
are missing or rejected. The procedure again consists of
I = the laboratories x samples interaction sum of squares
the set of Dixon r tests (see 4.2.3). applied to the
laboratory totals over all samples, with any estimated results
= (pairs sum of squares) -(laboratories sum of squares) -
included (see note in 4.3). If any laboratories are rejected
(sample sum of squares)
on all samples, new estimates must be calculated for any
Ignoring any pairs in which there are estimated values,
remaining missing values (see 5.1).
E = repeats sum of squares
5.2.1 Worked example
The procedure on the laboratory totals shown in table6
below follows exactly that specified in 4.2.3.
Laboratory I G I C H I D I A I B I E F J
* including estimated value.
IS0 4259-1979 (E)
Uncorrected pairs sum of squares
The purpose of performing this approximate analysis of
variance is to obtain the minimized laboratories x samples
L' S'
interaction sum of squares, 1. This is then used as indicated
= 112 C a; . . . (11)
in 5.3.1 .I, to obtain the laboratories sum of squares.
i-l/=l
If there were no estimated values, the above analysis of
where Si = 2 (L'-number of missing pairs in that
variance is exact and the following sub-clause should be
sample).
disregarded.
The laboratories sum of squares is equal to (pairs sum of
squares) - (samples sum of squares) - (the minimized
5.3.1.1 WORKED EXAMPLE
laboratories x samples interaction sum of squares).
Mean correction
- 350,81 52
-
= 854,660 5
Samples sum of squares
5.3.2.1 WORKED EXAMPLE
- 22,3022 + 72,5122 + . + 19,1922
Uncorrected samples sum of squares
-
- 854,660 5
- 19,8452 + 72,5122 + . + 19,1922
-- -
= 293,540 9
16 18 18
Laboratories sum of squares
= 1 145,1834
- 38,9922 + 39,0202 4- . + 39,3872
-
- 854,660 5
Uncorrected pairs sum of squares
2,5202 8,0412 2,238*
-
= 0,035 6 _-
+- + . +-
2 2 2
Pairs sum of squares
= 1 145,332 9
=1/2 (2,5202 + 8,0412 + . + 2,2382) - 854,660 5
Therefore, laboratories sum of squares
= 293,690 8
1 145,332 9 - 1 145,183 4 - 0,114 3
Repeats sum of squares
= 0,035 2
= 112 (0,0422 + 0,021* + . + 02)
= 0,021 9
5.3.3 Degrees of freedom
Table 8 can then be derived.
The degrees of freedom for the laboratories are (L' - 1). The
TAB LE 8 degrees of freedom for laboratories x samples interaction
are (L' - 1) (S'- 1) for a complete array and are reduced
Source of variation Sum of squares
by one for each pair which is estimated. The degrees of
293,540 9
Samples
freedom for repeats are (L'S') and are reduced by one for
Laboratories 0,035 6
each pair in which one or both values are estimated.
Laboratories X samples 0.1 14 3
Pairs 293,690 8
Repeats 0,021 9
- 5.3.3.1 WORKED EXAMPLE
There are eight samples and nine laboratories in this
example. As no complete laboratories or samples were
5.3.2 Forming the sum of squares for the exact analysis of
rejected, then S' = 8 and L' = 9.
variance
Laboratories degrees of freedom = L - 1 = 8
In this sub-clause, all the estimated pairs are disregarded
and new values of g are calculated. The following sums of
Laboratories x samples interaction degrees of freedom, if
squares for the exact analysis of varianceI3] are formed.
there has been no estimates, would have been (9- 1)
(8 - 1) = 56, But one pair was estimated, hence labora-
Uncorrected sample sum of squares
tories x samples interaction degrees of freedom = 55.
s' gi'
Repeats degrees of freedom would have been 72 if there
= v-
. . . (IO)
had been no estimates. In this case one pair was estimated,
L si
hence repeats degrees of freedom = 71.
j= 1
IS0 4259-1979 (E)
5.3.4 Mean squares and analysis of variance
Laboratories x samples : O: + y U:
The mean square in each case is the sum of squares divided Repeats : U:
by the degrees of freedom. This leads to the analysis of
where
variance shown in table 9.
TABLE 9
Source of Degrees of Sum of
variation freedom sauares
square
Laboratories Laboratories sum
of squares
Laboratories
Z
X samples - number of
estimated pairs
Repeats
L'S' - number E
of pairs in which
one or both
values are
where
nii is the number of results from the ith laboratory
5.3.4.1 WORKED EXAMPLE
on the jth sample, if tested;
The analysis of variance is shown in table IO.
Ni is the number of results in ith laboratory;
TABLE 10
N' is the total number of actual results minus
number of rejected results;
Source of Degrees of Sum of Mean
variation freedom squares square
K is the number of i XS cells containing a result.
Laboratories 8 0,035 2 0,004 400
Laboratories
If there are no cells with only a single estimated result, then
55 0,114 3 0.002 078
X samples
a=y=2
Repeats 71 0,021 9 0,000 308
NOTE -This sub-clause is based upon the assumptions that both
samples and laboratories are "random effects".
5.4.2.1 WORKED EXAMPLE
5.4 Expectation of mean square and calculation of
precision estimates
For the example, which has eight samples, and nine labora-
tories.
5.4.1 Expectation of mean square with no estimated
values
For a complete array with no estimated values, the expec-
tations of mean squares are
=2
Laboratories : U: + 2 U: + 2s U$
Laboratories x samples : U: + 2 U: /3= 142-
1 142
Repeats : U:
= 15,78
where
U: is the component of variance due to interaction
between laboratories and samples;
=2
U; is the component of variance due to differences
between laboratories.
5.4.3 Calculation of precision estimates
5.4.2 Expectation of mean square with estimated values
REPE ATAB I L ITY
5.4.3.1
The coefficients of U: and U; in the expression for mean
square are altered in the cases where there are estimated
The repeatability variance is twice the mean square for
values. The expectations of mean squares then become
repeats. The repeatability estimate is the product of the
repeatability standard deviation and the "t-value" with
l
Laboratories : U: + a U: + U$
appropriate degrees of freedom [see table 19 (annex DI.
I
IS0 4259-1979 (E)
5.4.3.2.1 Worked example
This calculated estimate shall be rounded down to the
nearest unit used in quoting the results, as a consequence
Reproducibility variance
of the definition of repeatability.
13,78
=Y- 15,78 0'004 40)(G
5.4.3.1 .I Worked example
= 0,000 558 + 0,001 81 5 + 0,000 308
Repeatability variance
= 0,002 681
= 2 U;
v = 7 188/(39 + 60 + 1)
= 0,000 616
7 188
Repeatability of y =-
I O0
= t,, d5jSô-m
= 72 (correct to nearest integer)
= 0,049 5
Reproducibility of y
Repeatability of x
= t72 40,002 681
= 3 x213 x 0,049 5
= 0,103 4
= 0,148 x2'3
Reproducibility of x
5.4.3.2 RE PROD U c IB IL ITY
= 0,31 O x2j3
Reproducibility variance = 2 (U; + U: 4- U;) and can be
5.5 Precision clause of a method of test
calculated using formula (13).
When the precision of a method of test has been deter-
Reproducibility variance
mined, according to the procedures set out in this Inter-
national Standard, it shall be included in the method as
follows :
"Range or sample
where the symbols are as set out in 5.3.4 and 5.4.2.
Repeatability Reproducibility
description
The reproducibility estimate is the product of the repro-
.......... .......... ..........
ducibility standard deviation and the "t-value" with
.......... .......... ..........
appropriate degrees of freedom [see table 19 (annex DI].
These precision values have been obtained using the
An approximation to the degrees of freedom of the repro-
procedures set out in IS0 4259."
is given by formula (14).
ducibility variance
(Reproducibility varianceI2
U= . (14) 6 SIGNIFICANCE OF REPEATABILITY r AND
rZj r5j
REPRODUCIBILITY R AS DISCUSSED IN EARLIER
- rr: +-+-
CLAUSES
L'-1 VLÇ v,
6.0 Introduction
where
The value of these quantities is estimated from analysis
r,, r2 and r3 are the three successive terms in formula
of variance (two-factor with replication) performed on the
(13);
results obtained in a statistically designed inter-laboratory
programme in which different laboratories each test a range
vLs is the degrees of freedom for laboratories x samples;
of samples. Repeatability and reproducibility values should
v, is the degrees of freedom for repeats.
be included in each published test method, and it is noted
that the latter is usually greater than the former, if derived
This calculated estimate shall also be rounded down to the
in accordance with this International Standard.
nearest unit used in quoting the results, as a consequence
of the definition of reproducibility.
6.1 Repeatability r
Note that if a transformation y = f(x) has been used, then
Most laboratories do not carry out more than one test on
each sample for routine quality control purposes, except in
(15)
abnormal circumstances, such as in cases of dispute or if the
test operator wishes to confirm that his technique is satis-
where R(x), R(y) are the corresponding reproducibility factory. In these abnormal circumstances, when multiple
functions. A similar relationship applies to the repeatability
results are obtained, it is useful to check the consistency of
functions r(x), r(y).
repeat results against the repeatability of the method and
IS0 4259-1979 (E)
the appropriate procedure is outlined in 6.1.1. It is also
However, since r for most test methods is much smaller
useful to know what degree of confidence can be placed in
than U, little improvement in the precision of the average
the average results, and the method of determining this is
is obtained by carrying out multiple testing under repeat-
given in 6.1.2.
ability conditions.
NOTE - If the reproducibility R of a test method has been found
6.1 .I Acceptability of results
considerably greater than twice the repeatability r, the reasons for
the large value of the ratio Rlr should be analysed and the method,
When only two results are obtained under repeatability
if possible, should be improved.
conditions and their difference is less than or equal to r,
the test operator may consider his work as being under
6.2 Reproducibility R
control and may take the average of the two results as the
estimated value of the property being tested.
6.2.1 Acceptability of results
If the two results differ by more than r, both shall be
The procedure specified in this sub-clause is intended for
considered as suspect and at least three more results
judging the acceptability, with respect to the reproducibility
obtained. The difference between the most divergent result
of the test method, of results obtained by different labo-
and the average of the remainder (including the first two)
ratories in normal day-to-day operations and transactions.
shall then be calculated and this difference compared with
In cases of dispute between a supplier and a recipient, the
the repeatability of the method. If the difference is less
procedure specified in clause 7 shall be adopted.
than or equal to r, all the results
...


Zd
I
I
@ 4259
ICrme internationale
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION*MEWlYHAPOflHAR OPTAHH3AUHR no CTAH~APTH3AUHM.ORGANlSATlON INTERNATIONALE DE NORMALISATION
0 Produits pétroliers - Détermination et application des
valeurs de fidélité relatives aux méthodes d'essai
Petroleum products - Determination and application of precision data in relation to methods of test
Première édition - 1979-11-15
G CDU 665.7 : 519.23 : 620.1 Réf. no : IS0 4259-1979 (FI
-
m
Descripteurs : produit pétrolier, résultat d'essai, fiabilité, analyse statistique, définition
c
Prix basé sur 27 pages
s
AVANT-PROPOS
L’ISO (Organisation internationale de normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (comités membres de I‘ISO). L‘élaboration
des Normes internationales est confiée aux comités techniques de I‘ISO. Chaque
comité membre intéressé par une étude a le droit de faire partie dia comité technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont
soumis aux comités membres pour approbation, avant leur acceptation comme
Normes internationales par le Conseil de I’ISO.
La Norme internationale IS0 4259 a été élaborée par le comité technique
ISO/TC 28, Produits pétroliers et lubrifiants, et a été soumise aux comités membres
en avril 1977.
Les comités membres des pays suivants l’ont approuvée :
Afrique du Sud, Rép. d’ Finlande Pologne
Allemagne, R.F. France Portugal
Australie Hongrie Roumanie
Autriche Inde Royaume-Uni
Brésil Iran Turquie
Bulgarie Israël
URSS
Canada Italie USA
Espagne Japon
Le comité membre du pays suivant l‘a désapprouvée pour des raisons techniques :
Suède
O organisation internationale de normalisation, 1979
I rnprimé en Suisse
i
SOMMAIRE Page
O Introduction . 1
1 Objet et domaine d'application . 1
2 Définitions . 1
e
3 Étapes de l'organisation d'un programme d'essai interlaboratoires pour la
détermination de la fidélité d'une méthode d'essai . 2
3.1 Préparation d'un projet de méthode d'essai . 3
3.2 Organisation d'un programme pilote avec au moins deux laboratoires . 3
3.3 Organisation du programme interlaboratoires . 3
3.4 Exécution du programme interlaboratoires . 3
4 Examen des résultats de l'essai interlaboratoires du point de vue de
l'uniformité et des valeurs aberrantes . 4
4.0 Introduction . 4
4.1 Transformation des données . 4
4.2 Recherche des valeurs aberrantes . 5
4.3 Rejet de tous les résultats concernant un échantillon . 6
5 Analyse de la variance et calcul des estimations de fidélité . 6
5.0 Introduction . 6
5.1 Estimation des valeurs manquantes ou rejetées . 7
5.2 Test de rejet des résultats d'un laboratoire . 7
5.3 Analyse de la variance . 7
5.4 Espérance des carrés moyens et calcul des estimations de fidélité . 9
i
5.5 Chapitre d'une méthode d'essai relatif à la fidélité . 11
6 Signification de la répétabilité r et de la reproductibilité R exposées dans les
chapitres précédents . 11
6.0 Introduction . 11
6.1 Répétabilitér . 11
6.2 Reproductibilité R . 11
t
7 Spécifications . 12
7.1 But des spécifications . 12
7.2 . 12
Établissement des spécifications
II
8 Contrôle de qualité et spécifications . 13
8.0 Introduction . 13
8.1 Marge de contrôle du fournisseur . 13
........................... 13
8.2 Marge de contrôle du réceptionnaire
et de non.conformit6. en cas de désaccord . 13
9 Règles de conformité
Annexes
Détermination du nombre d'échantillons requis . 15
A
Dérivation de la formule de calcul du nombre d'échantillons requis . 16
B
Notation et tests . 17
C
D Exemple de procédure pour l'étude des résultats de la détermination de
l'indice de brome . 20
E Types de dépendance et transformations correspondantes . 23
F Analyse de régression à une variable indépendante . 24
G Règles d'arrondissage des résultats . 27
H Explication des formules données en 6.1.2 et 6.2.2. . 28
Bibliographie . 28
...
Ill
NORME INTERNATIONALE IS0 4259-1979 (F)
Produits pétroliers - Détermination et application des
valeurs de fidélité relatives aux méthodes d'essai
O INTRODUCTION 2.2 variance uentre laboratoires)) : Lorsque des résultats
obtenus par plus d'un laboratoire sont comparés, la disper-
Pour les besoins de contrôle de qualité et pour vérifier leur
sion est normalement plus importante que lorsque le même
conformité aux spécifications, les caractéristiques des pro-
nombre d'essais est effectué par un seul laboratoire, et il y a
duits pétroliers commerciaux sont contrôlées selon des
des écarts entre les moyennes obtenues par les différents
méthodes d'essai normalisées de laboratoire. Deux ou plu-
laboratoires. Ces écarts donnent lieu à la variance entre
0 sieurs déterminations de la même caractéristique d'un
laboratoires qui est l'élément de la variance totale
échantillon donné, selon une méthode d'essai quelconque
par les différences entre les valeurs moyennes obtenues par
fixée, ne donnent généralement pas exactement le même
les différents laboratoires. (Il existe une définition corres-
résultat. II est donc nécessaire de tenir compte correcte-
pondante pour la variance entre opérateurs.)
ment de ce fait, en parvenant à des estimations de base
statistique de la fidélité d'une méthode, qui constituent
2.3 biais : Différence entre la valeur vraie (associée à la
une mesure objective du degré de concordance à attendre
méthode d'essai) (voir 2.24) et la valeur connue (voir 2.81,
entre deux ou plusieurs résultats obtenus dans des condi-
lorsque celle-ci est disponible.
tions données.
2.4 codage : Attribution d'un numéro différent pour
chaque échantillon, ce même numéro étant valable pour
1 OBJET ET DOMAINE D'APPLICATION
les répétitions. Aucune autre identification ou informa-
tion sur les échantillons n'est donnée à l'opérateur.
La présente Norme internationale traite du calcul des esti-
mations de fidélité et leurs applications aux spécifications.
2.5 échantillon de contrôle : Échantillon prélevé au lieu
En particulier, elle contient les définitions des termes statis-
où le produit est échangé, c'est-à-dire où la responsabilité
tiques concernés (voir chapitre 2), les procédures à suivre
de la qualité du produit passe du fournisseur au réception-
dans l'organisation d'un programme d'essai interlaboratoires
naire.
destiné à déterminer la fidélité d'une méthode d'essai (voir
chapitre 3), la méthode de calcul de la fidélité à partir des
résultats d'un tel programme (voir chapitres 4 et 51, et la
2.6 degrés de liberté : Diviseur utilisé dans le calcul de la
procédure à suivre dans l'interprétation des résultats de
variance; une unité de moins que le nombre de résultats
laboratoire à la lumière à la fois de la fidélité des méthodes
indépendants.
et des limites fixées dans les spécifications (voir chapitres 6
NOTE - La définition n'est strictement applicable que dans les cas
à 9).
les plus simples. Des définitions plus completes sont en dehors de
l'objet de la présente Norme internationale.
On doit insister sur le fait que les procédures de la présente
Norme internationale sont destinées à couvrir seulement les
méthodes d'essai des produits pétroliers. Ces produits sont
2.7 détermination : Exécution de la série d'opérations
généralement homogènes et ne soulèvent pas normalement
spécifiées dans la méthode d'essai et permettant d'obtenir
de difficiles problèmes d'échantillonnage. II ne serait donc
une seule valeur.
pas justifié de considérer que ces procédures puissent être
appliquées à des domaines plus larges, par exemple aux
2.8 valeur connue : Valeur quantitative réelle découlant de
solides hétérogènes.
la préparation de l'échantillon.
NOTE - La valeur connue n'existe pas toujours, par exemple dans
le cas d'essais empiriques tels que la détermination du point d'éclair.
2 DÉFINITIONS
Dans le cadre de la présente Norme internationale, les défi- 2.9 moyenne; moyenne arithmétique : Pour une série
donnée de résultats, somme des résultats divisée par leur
nitions suivantes sont applicables :
nombre.
2.1 analyse de la variance : Technique qui permet de
2.10 moyenne des carrés : Somme des carrés divisée par le
décomposer la variance totale d'une méthode en ses diffé-
nombre de degrés de liberté.
rents facteurs composants.
IS0 4259-1979 (F)
2.19 reproductibilité :
2.1 1 distribution normale : Distribution de probabilité
d'une variable aléatoire continue X, telle que, si x est un
a) Qualitativement
nombre réel quelconque, la densité de probabilité est
Étroitesse de l'accord entre les résultats individuels
obtenus dans l'exécution normale et correcte de la même
méthode sur un produit identique soumis à l'essai, mais
dans des conditions différentes (opérateurs différents,
appareillages différents et laboratoires différents).
-m NOTE - Les parametres représentatifs de la dispersion de la
population qui peut être associée aux résultats sont qualifiés
NOTE - g est la valeur vraie et U est l'écart-type de la distribution
du terme «reproductibilité)), par exemple écart-type de repro-
normale (U > O).
ductibilité, variance de reproductibilité.
2.12 opérateur : Personne qui effectue normalement et b) Quantitativement
régulièrement un essai particulier.
Valeur à laquelle la différence absolue entre deux résul-
tats individuels sur un produit identique obtenus par des
2.13 valeur aberrante : Résultat dont la valeur est suffi-
opérateurs dans des laboratoires différents, en utilisant
samment éloignée des autres résultats pour qu'il ne soit pas
la méthode d'essai normalisée, doit rester égale ou infé-
considéré comme faisant partie de l'ensemble des résultats.
rieure, pour une probabilité spécifiée; en l'absence
d'autre indication, le niveau de probabilité est de 95 %.
2.14 fidélité : Étroitesse de l'accord entre les résultats
obtenus en appliquant le procédé expérimental à plusieurs
2.20 résultat: Valeur finale obtenus en suivant le mode
reprises sur des produits identiques et dans des conditions
opératoire complet de la méthode d'essai; suivant les ins-
déterminées. Le procédé est d'autant plus fidèle que la
tructions de la méthode, cette valeur peut être obtenue au
partie aléatoire des erreurs expérimentales qui affectent
moyen d'une seule ou de plusieurs déterminations. (il est
les résultats est moindre.
admis que tous les résultats sont arrondis conformément à
la procédure spécifiée dans l'annexe G.)
2.15 erreur aléatoire : Possibilité d'erreurs dans tout essai,
en dépit du meilleur contrôle possible des variables.
2.21 écart-type : Mesure de la dispersion d'une série de
résultats autour de leur moyenne, égale à la racine carrée
2.16 réceptionnaire : Toute personne physique ou morale
positive de la variance et estimée par la racine carrée posi-
qui reçoit ou accepte le produit livré par le fournisseur.
tive de la moyenne des carrés.
2.17 répétabilité :
2.22 somme des carrés : Somme des carrés de la différence
entre une série de résultats et leur moyenne.
a) Qualitativement
Étroitesse de l'accord entre les résultats successifs obte-
2.23 fournisseur : Toute personne physique ou morale
nus dans l'exécution normale et correcte de la même
responsable de la qualité d'un produit juste avant qu'il ne
méthode sur un produit identique soumis à l'essai, dans
soit pris en charge par le réceptionnaire.
les mêmes conditions (même opérateur, même appareil-
lage, même laboratoire et courts intervalles de temps).
2.24 valeur vraie : Pour les besoins pratiques, valeur vers
NOTE - Les paramètres représentatifs de la dispersion de la
laquelle tend la moyenne des résultats individuels obtenus
population qui peut être associée aux résultats sont qualifiés du
par n laboratoires, lorsque n tend vers l'infini. En consé-
terme ((répétabilité)). par exemple écart-type de répétabilité,
quence, une valeur vraie ainsi définie est associée à chaque
variance de répétabilité.
méthode d'essai particulière.
b) Quantitativement
NOTE - Une définition différente et idéalisée est donnée dans
I'ISO 3534, Statistique - Vocabulaire et symboles.
à laquelle la différence absolue entre deux résul-
Valeur
tats individuels obtenus dans les conditions ci-dessus doit
2.25 variance : Moyenne des carrés de l'écart d'une
rester égale ou inférieure, pour une probabilité spécifiée;
variable aléatoire par rapport à sa moyenne.
en l'absence d'autre indication, le niveau de probabilité
est de 95 %.
3 ÉTAPES DE L'ORGANISATION D'UN
2.18 répétition : Exécution d'une méthode d'essai plus PROGRAMME D'ESSAI INTER LABORATOI R ES
d'une fois pour amélidrer la fidélité et obtenir une estima- POUR LA DETERMINATION DE LA FIDELITE
tion plus étroite de l'erreur d'échantillonnage. Une répéti- D'UNE MÉTHODE D'ESSAI
tion doit être distinguée d'une redétermination dans la
Les étapes de l'organisation d'un programme d'essai inter-
mesure où le premier terme implique que les essais sont
laboratoires sont les suivantes :
effectués à un seul endroit et, autant que possible, sur une
seule période de temps. a) Préparation d'un projet de méthode d'essai.
IS0 4259-1979 (F)
b) Organisation d'un programme pilote avec deux composantes de variance obtenues dans le programme
laboratoires. pilote. Spécifiquement, P est le rapport de la composante
interaction à la composante répétitions, et O est le rapport
c) Organisation du programme interlaboratoires.
de la composante laboratoires à la composante répétitions.
L'annexe B donne le calcul de la formule utilisée. Si O est
d) Exécution du programme interlaboratoires.
beaucoup plus grand que P, les 30 degrés de liberté ne peu-
Les quatre étapes sont décrites successivement. vent être atteints : i'entrée vide dans la table l l correspond
à cette situation ou à une situation proche (c'est-à-dire
lorsque plus de 20 échantillons sont requis). Dans ces cas,
3.1 Préparation d'un projet de méthode d'essai
il doit y avoir un biais significatif entre laboratoires.
Celui-ci doit contenir tous les détails nécessaires pour
de l'essai et l'expression des résultats. Toute
l'exécution
3.4 Exécution du programme interlaboratoires
condition susceptible d'avoir une influence sur les résul-
tats doit être spécifiée.
Une personne doit être responsable du programme entier,
depuis la distribution des textes et des échantillons jusqu'à
Seul le titre du chapitre relatif à la fidélité figurera à ce
l'application finale des résultats. Elle doit bien connaître la
stade.
méthode, mais ne doit pas prendre part personnellement
aux essais.
3.2 Organisation d'un programme pilote avec au moins
deux laboratoires Le texte de la méthode doit être diffusé à tous les labora-
toires à temps pour leur permettre de soulever d'éventuelles
Un programme pilote est nécessaire pour les raisons sui-
questions avant le début des essais. Si un laboratoire désire
vantes :
pratiquer la méthode à l'avance, cela devrait être fait sur des
échantillons autres que ceux utilisés dans le programme.
a) pour vérifier les détails de l'opération de l'essai;
Les échantillons doivent être réunis, divisés et distribués par
b) pour déterminer dans quelle mesure les opérateurs
l'organisateur qui doit également conserver une réserve de
peuvent observer correctement les instructions de la
chaque échantillon pour les cas d'urgence. II est de la plus
méthode;
haute importance que les parties fractionnées pour chaque
c) pour contrôler les instructions concernant les échan-
laboratoire soient homogènes. Celles-ci doivent être codées
tillons;
avant la distribution, et les instructions suivantes doivent
accompagner leur envoi :
d) pour estimer grossièrement la fidélité de l'essai.
a) le projet de méthode choisi pour les essais;
Au moins deux échantillons sont nécessaires, couvrant la
plage de résultats pour laquelle l'essai est destiné s'appliquer;
b) les instructions pour la manipulation et le stockage
cependant, au moins 12 combinaisons laboratoire/échan-
des échantillons;
tillon devraient être incluses. Chaque échantillon est essayé
c) l'ordre dans lequel les échantillons doivent être
deux fois par chaque laboratoire dans les conditions de
essayés (un ordre aléatoire différent pour chaque labora-
répétabilité. Si des omissions ou des imprécisions dans le
toire);
projet de méthode sont révélées, elles doivent alors être
d) l'indication que deux résultats doivent être obtenus
corrigées. Les résultats doivent être analysés sous l'angle du
consécutivement sur chaque échantillon, par le même
biais et de la fidélité : si l'un ou l'autre paraît trop impor-
opérateur avec le même appareillage;
tant, des modifications à la méthode doivent être envisagées.
e) la période durant laquelle tous les échantillons
3.3 Organisation du programme interlaboratoires doivent être essayés;
f) la manière de reporter les résultats. Pour chaque
Celui-ci doit recueillir la participation d'au moins cinq
échantillon, il doit être prévu la date de l'essai, les deux
laboratoires, mais il est préférable de dépasser ce nombre
résultats et toute circonstance inhabituelle. Le degré
pour réduire le nombre d'échantillons requis.
de précision pour l'expression des résultats doit être
spécifié;
Le nombre d'échantillons doit être suffisant pour couvrir
la plage de la propriété mesurée, et rendre représentatives
g) l'indication que l'essai doit être exécuté dans des
les estimations de fidélité. Si une quelconque variation de la
conditions normales, par des opérateurs ayant acquis
fidélité avec le niveau était observée dans les résultats du
une expérience bonne mais qui n'est pas exceptionnelle;
programme pilote, il serait nécessaire d'utiliser au moins
et que la durée de l'essai doit être la même qu'à la nor-
cinq échantillons dans le programme interlaboratoires. Dans
male.
tous les cas, il est recommandé de viser 30 degrés de liberté,
NOTE - Les opérateurs du programme pilote peuvent prendre
à la fois pour la répétabilité et la reproductibilité. Pour la
part au programme interlaboratoires. Si leur extra-expérience
l
répétabilité, cela signifie un total de 30 paires de résultats
dans l'essai de quelques échantillons de plus produit un effet
dans le programme. Pour la reproductibilité, la table 11
notable, elle devrait servir d'avertissement en ce sens que la
(annexe A) donne le nombre d'échantillons requis en fonc-
méthode n'est pas satisfaisante. Ils devraient être identifiés
tion de L, P et O, où L est le nombre de laboratoires parti-
dans le compte rendu des résultats de sorte que tout effet
puisse être noté.
cipiants, et P et 0 sont les rapports des estimations des
IS0 4259 -1 979 ( F)
4 EXAMEN DES RÉSULTATS DE L'ESSAI
S'il apparaît un coefficient de régression significativement
INTERLABORATOIRES DU POINT DE VUE DE
différent de zéro donnant une dépendance de la forme
L'UNIFORMITÉ ET DES VALEURS ABERRANTES
D = f(m), la transformation adéquate y = F(x), où x est
le résultat, est donnée par la formule
4.0 Introduction
dx
Le présent chapitre spécifie les procédures d'examen des
Fix) = k . . . (2)
résultats exprimés dans un essai circulaire organisé dans un
but statistique (voir chapitre 3) pour établir
où k est une constante.
a) l'indépendance de la fidélité,
b) le niveau des résultats, Les cas particuliers les pius courants sont indiqués dans la
table 20 (annexe E) avec les transformations correspon-
la fidélité d'un laboratoire à un autre,
c) l'uniformité de
dantes. Une correspondance linéaire entre log Di et log mi
et pour détecter la présence de valeurs aberrantes. Les pro-
révèle une relation de la torme D = AmB.
cédures sont décrites en termes mathématiques basés sur
Le choix d'une transformation est difficile pour faire le
la notation de l'annexe C et illustrées par des références à
sujet de règles formelles, et une assistance statistique
l'exemple de calcul de l'indice de brome exposé dans
qualifiée peut être nécessaire dans certains cas particuliers.
l'annexe D.
Dans le présent chapitre (et le chapitre 5), les procédures à
Après le choix d'une transformation sur la base d'une rela-
employer sont d'abord spécifiées, puis illustrées par un
tion entre D et m, il doit être vérifié que la même transfor-
exemple en utilisant les résultats donnés dans l'annexe D.
mation est également valable pour l'écart-type, d, de
répétabilité (voir annexe C, chapitre C.3). Si ce n'est pas le
II est supposé, dans la suite du présent chapitre, que tous les
cas, soit une transformation particulière sera nécessaire, soit
résultats soit appartiennent à une distribution normale
les résultats ne nécessiteront pas de transformation pour le
unique, soit sont susceptibles d'être transformés en une
calcul de la répétabilité.
telle distribution (voir 4.1). Les autres cas (qui sont rares)
nécessiteraient un traitement différent qui n'est pas dans
l'objet de la présente Norme internationale. 4.1 .I Exemple
Dans le cas de l'exemple donné dans l'annexe D, les valeurs
4.1 Transformation des données
de m, D et d, pour les huit échantillons, figurent dans la
table 1.
Dans de nombreuses méthodes d'essai, la fidélité dépend du
niveau du résultat de l'essai, et donc la dispersion des
De l'examen des nombres de la table 1, il peut être constaté
résultats notés diffère d'un échantillon à un autre. La
qu'à la fois D et d augmentent avec m, mais d'autant moins
méthode d'analyse décrite dans la présente Norme inter-
rapidement que m est plus grand. Si l'on reporte ces
nationale suppose qu'il n'en est pas ainsi, et la situation est
nombres sur un papier log-log (c'est-à-dire si l'on réalise un
corrigée, si nécessaire, par une transformation.
graphique de log D et log d en fonction de log m), on
Les écarts-types, Di. des laboratoires (voir annexe C, cha-
constate que les points sont disposés approximativement
pitre C.3) sont calculés et portés en regard des moyennes,
suivant deux lignes droites (voir annexe F, figure). Les
m., des échantillons. Si les points ainsi obtenus sont
.J pentes de ces droites sont respectivement 0,64 et 0,58, et,
disposés approximativement suivant une droite parallèle à
si l'on tient compte des erreurs d'estimation de ces pentes,
l'axe des m, il n'est pas nécessaire de procéder à une trans-
on peut admettre qu'il s'agit de droites parallèles de pente
formation. Mais, si les points sont disposés approximative-
213.
ment suivant une courbe de type D = fh), il faut procéder
à une transformation.
Par conséquent, la même transformation convient pour la
répétabilité et la reproductibilité, et est donnée par la
La relation D = f(m) est plus facile à établir selon la tech-
formule
nique d'analyse de régression à une variable indépendante
(il faudrait, en réalité, faire appel à une régression itérative
pondérée, mais, dans la plupart des cas, une régression non
Puisqu'on peut négliger le coefficient constant, la trans-
pondérée constitue une approximation suffisante).
formation se réduit à l'extraction des racines cubiques des
est donné dans l'annexe F,
Un exposé des calculs nécessaires
résultats obtenus (indices de brome). Cette opération
mais il s'agit d'un programme normalisé pour la plupart des
fournit les données transformées figurant dans la table 16
ordinateurs. Habituellement, un niveau de probabilité de
(annexe D), dans laquelle les racines cubiques sont données
5% est utilisé pour déterminer si un coefficient de
avec trois décimales.
régression est différent de zéro.
TABLE 1
Numéro de
3 8 1 4 5 6 2 7
l'échantillon
m
0,756 1.22 2,15 3,64 10,9 48,2 65,4 114
D 0,067 0,159
0,729 0,211 0,291 1.50 2.22 2.93
I I l I. I.
d 10,050 0 1 0,057 2 I 0,127 I 0,115 I 0,094 3 I 0,527
0,817 I 0,935
I
IS0 4259-1979 (FI
4.2 Recherche des valeurs aberrantes L'écart le plus grand est 0,078 pour le laboratoire G sur
l'échantillon 3. La somme des carrés de tous les écarts est
Après avoir appliqué aux données expérimentales la ou
0,042' + 0,021' + . t 0,026' + O2 = 0,043 9
les transformations appropriées, ou décidé que cela n'était
pas nécessaire, il faut étudier les résultats transformés pour
Par suite, le rapport à comparer au critère de Cochran est
rechercher les valeurs aberrantes. Ce sont des valeurs si
différentes des autres qu'il peut être admis qu'elles pro-
-- 0'078' - 0,138
viennent d'une quelconque erreur dans l'application de la
0,043 9
méthode, ou de l'essai d'un mauvais échantillon. On peut
utiliser de nombreux tests d'élimination et faire varier les II y a 72 paires et, comme dans la table 17 (annexe D), le
seuils de signification associés, mais on a constaté que ceux critère pour 75 paires est 0,180 9, ce rapport n'est pas
recommandés ci-après conviennent à l'objet de la présente significatif.
Norme internationale.
de la reproductibilité
4.2.3 Uniformité
4.2.1 Uniformité de la répétabilité
Les autres recherches de valeurs aberrantes s'attachent à
établir l'uniformité de la reproductibilité estimée. Elles ont
Le premier test de recherche des valeurs aberrantes a pour
pour but de déceler soit une paire de résultats discordants
but de détecter un résultat discordant dans une paire de
résultats répétés. Ce test[' 1 implique le calcul de e$ sur obtenus par un laboratoire sur un échantillon particulier,
soit un groupe de résultats discordants provenant d'un labo-
toutes les combinaisons laboratoire/échantillon. On
ratoire sur tous les échantillons. Dans ces deux recherches,
applique ensuite le critère de Cochran au niveau de 1 % au
on peut utiliser l'un des tests de Dixon (r)f2I. II s'agit de
rapport de la plus grande de ces valeurs à leur somme (voir
annexe C, chapitre C.4). Si sa valeur dépasse la valeur former, pour chaque échantillon puis pour la somme des
donnée dans la table 17 (annexe DI, correspondant à un résultats de chaque laboratoire (voir 5.2), les rapports de
diverses différences entre les sommes de paires de résultats
niveau de probabilité de 1 %, k étant le nombre de paires
aii (voir annexe C, chapitre C.5).
soumises à comparaison, il faut rejeter l'élément de la paire
qui est le plus éloigné de la moyenne de l'échantillon. On
Le rapport approprié est comparé aux valeurs critiques 1 %
répète la procédure en réduisant k d'une unité jusqu'à ce
données dans la table 18 (annexe D), n étant le nombre de
qu'il ne soit plus nécessaire de rejeter des valeurs. Dans
laboratoires concernés. Si une valeur significative se mani-
certains cas, ce test fait ((boule de neige)) et conduit à une
feste pour un ou plusieurs échantillons, il faut rejeter les
proportion de rejets inacceptable (par exemple plus de
valeurs extrêmes correspondantes et répéter la procédure.
10 %). Dans ce cas, il faut abandonner ce test de rejet et
Si l'on trouve une valeur extrême parmi les sommes de
conserver quelques-uns ou la totalité des résultats rejetés.
il faut rejeter tous les
résultats de chaque laboratoire,
Une décision arbitraire basée sur un jugement est alors
résultats provenant du ou des laboratoires correspondants.
nécessai re.
4.2.3.1 EXEMPLE
4.2.2 Exemple
L'application du test de Dixon est exposée en détail ci-après
Dans le cas de l'exemple donné dans l'annexe D, les diffé- pour le cas de l'échantillon 1. (Voir la note.)
rences entre les résultats rejetés transformés, c'est-à-dire
La première étape consiste à placer les sommes de paires de
entre les paires de nombres de la table 16, en unités de la
chaque laboratoire qui a fait l'essai sur l'échantillon 1 en
troisième décimale, figurent dans la table 2.
ordre croissant, comme indiqué dans la table 3.
TABLE 2
Le rapport de Dixon convenant pour neuf laboratoires est
rl 1.
11213 6 17 18
Pour tester la valeur la plus haute,
3,188 - 2,562
-
rll - 3,188 - 2,409
= 0,804
29 20
O0
Cette valeur est plus grande que la valeur de la table 18, et
H 44 O
les résultats du laboratoire D sur cet échantillon doivent
40 O
être rejetés.
TAE -E 3
1 Laboratoire ]BI FI C HI El AI G.IJ I D
I 2,409 1 2,409 I 2,432 2,476 1 2,497 I 2,520 12,540 12,562 13,188
I Somme des résultats
IS0 4259-1979 (F)
Puisqu'il y a eu rejet, la procédure doit être répétée pour NOTE .- À ce stade, il est souhaitable de vérifier que les rejets
effectués n'invalident pas la transformation utilisée. Si nécessaire,
les hautes valeurs, sans tenir compte des résultats du labora-
4.1 doit être répétée, sans tenir compte des valeurs
la procédure de
toire D. Cela donne
aberrantes.
- 2,562 - 2,540
4.3.1 Exemple
r1 ' - 2,562 - 2,409
Les écarts-types des laboratoires des résultats transformés,
= 0,144
après rejet de la paire de résultats du laboratoire D sur
La comparaison de cette valeur avec la valeur correspon-
l'échantillon 1, sont donnés dans la table 4 par ordre crois-
dante de la table 18 (annexe DI, pour huit laboratoires, per-
sant de la valeur moyenne obtenue sur l'échantillon.
met de constater qu'elle n'est pas significative et qu'il n'y a
L'étude de ces données permet de constater qu'il n'y a pas
pas de nouvelles valeurs aberrantes.
d'échantillon aberrant. II est à noter que les écarts-types des
Pour tester la valeur la plus basse,
laboratoires sont maintenant indépendants des moyennes
des échantillons, ce qui était bien le but de la transforma-
- 2,409 - 2,409
tion des résultats. Dans le cas étudié, il n'a pas été jugé
r1 - 2,562 - 2,409
utile de refaire les calculs après avoir éliminé les valeurs
aberrantes.
=O
Les nombres de la table 5, extraits d'un programme d'essai
Cette valeur est comparée avec la valeur correspondante de
sur l'indice de brome devaleur supérieure à 100, illustreront
la table 18 (annexe DI, soit 0,677.
le cas d'un rejet d'échantillon.
Puisque lavaleur calculée est inférieure à celle de la table 18,
L'étude de ces données permet de constater immédiatement
il n'y a pas de valeurs aberrantes dans les valeurs basses.
que l'écart-type des laboratoires pour l'échantillon 93
Cette procédure est répétée pour chaque échantillon. Dans (15,261 est beaucoup plus grand que les autres qui sont
cet exemple, il n'y a pas d'autres rapports significatifs et les tous du même ordre de grandeur entre 3,85 et 5,lO; cet
échantillon doit donc être rejeté. II est à noter que les
seuls rejets effectués sont ceux des résultats obtenus par le
laboratoire D sur l'échantillon 1. valeurs de l'écart-type des répétitions tendent également
à confirmer que cet échantillon est aberrant.
NOTE - Si les deux valeurs les plus basses ou les deux valeurs les
plus hautes sont égales, il peut n'y avoir aucune valeur aberrante
correspondante.
4.3 Rejet de tous les résultats concernant un échantillon
II faut examiner l'écart-type des laboratoires et l'écart-type 5 ANALYSE DE LA VARIANCE ET CALCUL DES
des répétitions en vue de déceler la présence d'échantillons ESTIMATIONS DE FIDÉLITÉ
aberrants. Si l'on a procédé à une transformation ou si un
rejet a été fait, il faut calculer de nouveaux écarts-types.
5.0 Introduction
Si l'écart-type pour l'un des échantillons est beaucoup trop
Après avoir contrôlé l'uniformité des résultats, effectué une
grand, il faut l'examiner avec l'idée de rejeter les résultats
transformation et rejeté les valeurs aberrantes (voir
de cet échantillon. II n'est pas possible de formuler un chapitre41, on procède à une analyse de variance. En
critère exact pour définir ce qu'on entend par l'expression premier lieu, les valeurs manquantes sont estimées selon la
((beaucoup trop grand)) dans ce contexte, mais il apparaît méthode des moindres carrés. On procède ensuite à I'éta-
qu'une telle décision ne devrait être prise que dans des cas blissement d'une table d'analyse de variance, puis on déter-
extrêmes1 ). mine les estimations de fidélité.
Numéro de l'échantillon 3 8 1 4 5 6 2 7
4,028 4,851
Moyenne de l'échantillon 0,910 1 1,066 1,240 1,538 2,217 3,639
0,037 8 0,044 8 0,041 0
Écart-type des laboratoires 0,027 8 0,047 4 0,035 7 0,029 7 0,019 6
95 96
91 94
89 93 92
Numéro de l'échantillon
139,4 159,5
Moyenne de l'échantillon 96,l 99.8 119,3 125,4 126,O 139.1
4.74 3,85
4,40 4 ,O9 4,87
5.10 4,20 15.26
Écart-type des laboratoires
1,12 1,36
0.91 0,73 1,32
1,13 0,99 2,97
des répétitions
Écart-type
1 ) II existe un test qui peut se révéler adéquat, mais pour lequel on ne dispose d'aucune expérience dans ce contexte. II s'agit d'utiliser le
rapport du maximum au minimum d'un groupe de variances (au niveau 1 %), conformément à la description donnée dans Biometrika rabies for
statisticians, volume 1, table 31.
IS0 4259-1979 (F)
5.1 Estimation des valeurs manquantes ou rejetées
Par conséquent, l'estimation de a4, est donnée par
-
5.1 .I Cas où l'une des valeurs répétées est manquante ou
[(9 x 36,354) + (8 x 19,845) - 348,3581
ai) -
(9-1) (8-1)
rejetée
II vient
Si l'une des valeurs d'une paire de résultats répétés (yiil ou
yjjz) est manquante ou rejetée, on la considère égale à
l'autre valeur de la paire, conformément à la méthode des
moindres carrés.
5.2 Test de rejet des résultats d'un .-,oratoire
5.1.2 Cas où les deux valeurs répétées sont manquantes ou
rejetées
À ce stade, il ne reste plus qu'un test de rejet à effectuer.
Celui-ci détermine s'il est nécessaire de rejeter l'intégralité
Si les deux valeurs répétées sont manquantes, on fait des
des résultats obtenus par un laboratoire particulier. Ce test
estimations de aii (= yijl + yijz) en formant la somme des
ne pouvait pas être fait précédemment à moins qu'il n'y ait
carrés de l'interaction laboratoires x échantillons, en y
eu ni rejet, ni aucun résultat manquant. Ici encore, la pro-
incorporant, sous forme de variables inconnues, les valeurs
cédure à suivre est une série de tests de Dixon (r) (voir
manquantes dans la somme des paires de résultats labora-
4.2.3) appliqués aux totaux du laboratoire par rapport à
toire/échantillon. Un laboratoire dont tous les résultats ont
tous les échantillons, les résultats estimés étant inclus s'il y
été rejetés selon le test de Dixon doit être purement et sim-
en a (voir note à 4.3). Si l'on a éliminé un laboratoire pour
plement éliminé; il faut alors utiliser la nouvelle valeur de L.
tous les échantillons, les estimations de toutes les valeurs
On évalue les valeurs manquantes ou rejetées en formant les
manquantes restantes (voir 5.1 1 doivent être calculées.
dérivées partielles de cette somme de carrés par rapport à
chaque variable, l'une après l'autre, et en égalant ces équa-
5.2.1 Exemple
tions à zéro pour les résoudre comme un groupe d'équations
simultanées.
La procédure exposée ci-après, relative aux totaux des labo-
ratoires (voir table 6). est identique à celle qui est spécifiée
La formule (4) peut être utilisée lorsqu'on veut estimer une
en 4.2.3.
seule somme de résultats rejetés. Si l'on doit évaluer
plusieurs paires, se reporter à la référence [5].
La table 7 résume les rapports de Dixon calculés.
Si l'on doit estimer la valeur d'une seule somme ajp cette
TABLE 7
estimation est donnée par la formule
I Rapport I rl I 1
I inférieur I 0.282 I
. . . (4)
1SuMrieur I 0,095 I

La comparaison avec la valeur de la table 18 (annexe D)
S' = S - nombre d'échantillons rejetés en 4.3;
permet de constater qu'aucun de ces rapports n'est signi-
e
ficatif et que, par conséquent, aucune élimination de labo-
L est le total des résultats restant du jeme laboratoire;
ratoire n'est nécessaire.
SI est le total des résultats restantsdu j*me échantillon;
5.3 Analyse de la variance
T est le total de tous les résultats sauf ajj.
f
5.3.1 Calcul des sommes des carrés pour la somme des
5.1.2.1 EXEMPLE
carrés de l'in teraction laboratoires x échantillons
Les deux résultats du laboratoire D sur l'échantillon 1 ont
Les valeurs estimées, s'il en existe, sont insérées dans le
été rejetés (voir 4.2) et, par suite, a4 doit être estimé.
tableau des résultats. On procède ensuite à une analyse
Total des résultats restants du laboratoire D = 36,354
approximative de la variance.
Total des résultats restants de l'échantillon 1 = 19,845
Correction moyenne
Total de tous les résultats sauf a4 = 348,358 M= PI2L'S'
. . (5)
On a égaiement S' = 8 et L = 9. où L' = L - nombre de laboratoires rejetés en 5.2.
TABLE 6
Laboratoire I G I C I H I D I A I B I E I F I J
Total I 38,560 I 38,777 I 38,840 1 38.811" I 38,992 I 39,020 I 39,099 I 39,329 I 39,387
Y compris la valeur estimée.
IS0 4259-1979 (F)
Somme des carrés des paires
Somme des carrés des échantillons
=1/2 (2,5202 + 8,0412 + . + 2,2382) - 854,660 5
r 1
. . . (6) = 293,690 8
Somme des carrés des répétitions
J
= 1/2 (0,0422 + 0,021* -t . + 02)
Somme des carrés des laboratoires
= 0,021 9
On peut alors obtenir la table 8,
L -I
TABLE 8
Somme des carrés
Somme des carrés des paires Origine de la variation
I
Échantillons 293,540 9
Laboratoires 0,035 6
r Lf st i
Laboratoires X échantillons 0.1 14 3
. . . (8)
= 112 p
a; J -M
1-1 1-1
Paires 293,690 8
I = somme des carrés de l'interaction laboratoires x
échantil Ions
5.3.2 Calcul de la somme des carrés pour l'analyse exacte
de la variance
= (somme des carrés des paires) - (somme des carrés des
Dans ce paragraphe, on néglige toutes les valeurs estimées et
laboratoires) - (somme des carrés des échantillons).
on calcule de nouvelles valeurs de g. On calcule comme suit
les paires dans lesquelles il y a des valeurs les sommesdescarréspour l'analyse exacte de la varianceI3I :
En négligeant
estimées,
Somme non corrigée des carrés des échantillons
E = somme des carrés des répétitions
gi"
. . . (IO)
I ' S'
=c,
]=I '
=I122 ce:, .
Somme non corrigée des carrés des paires
1-11 1
L' S'
Cette analyse approximative de la variance a pour but
= 112 C a? . . . (1 1)
d'obtenir la valeur minimale de I, somme des carrés de
Il
l'interaction laboratoires x échantillons. Cette valeur est i= ?I= 1
ensuite utilisée, comme indiqué en 5.3.1 .I, pour obtenir la
où S. = 2 (L' - nombre de paires manquantes pour cet
J
somme des carrés des laboratoires.
échantil Ion).
S'il n'existe pas de valeurs estimées, l'analyse de variance
La somme des carrés des laboratoires est égale à (somme des
précédente est exacte et le paragraphe suivant est nul et
carrés des paires) - (somme des carrés des échantillons) -
non avenu.
(somme rendue minimale des carrés de l'interaction labora-
toires x échantillons), c'est-à-dire
5.3.1.1 EXEMPLE
Correction moyenne
1 . . . (12)
1 /2
- 350,81 52
-
5.3.2.1 Ex EM P LE
= 854,660 5
Somme non corrigée des carrés des échantillons
Somme des carrés des échantillons
- 19,8452 + 72,5122 + . + 19,1922
22,3022 + 72,5122 + . + 19,1922
-- -
- -
- 854,660 5
16 18 18
= 1 145,1834
= 293,540 9
Somme des carrés des laboratoires Somme non corrigée des carrés des paires
2,5202 80412 2,2382
38,9922 + 39,0202 + . + 39,3872
-
- -
--
+-+ . +-
-- 854,660 5
2 2 2
= 0,035 6
= 1 145,332 9
IS0 4259-1979 (FI
Par conséquent, somme des carrés des laboratoires
5.4 Espérance des carrés moyens et calcul des estimations
de fidélité
= 1 145,332 9 ~ 1 145,183 4 - 0,114 3
= 0,035 2
5.4.1 Espérance des carrés moyens en l'absence de valeurs
5.3.3 Degrés de liberté
estimées
Les degrés de liberté pour les laboratoires sont (L' - 1). Les
Dans le cas d'une table complète sans valeurs estimées, les
degrés de liberté pour l'interaction laboratoires X échan-
espérances mathématiques des carrés moyens sont
tillons sont (L' - 1) (S'- 1) pour une table complète, et ils
sont réduits d'une unité pour chaque paire estimée. Les
Laboratoires : U; + 2 U: + 2s 02
degrés de liberté des répétitions sont (L'S'), et ils sont
Laboratoires x échantillons : U; + 2 U:
réduits d'une unité pour chaque paire dans laquelle une
valeur ou les deux ont été estimées.
Répétitions : U;

5.3.3.1 EXEMPLE
Dans cet exemple, il y a huit échantillons et neuf labora-
est la composante de la variance due à l'interaction
U:
toires. Puisqu'il n'y a pas eu rejet complet d'un laboratoire
entre les laboratoires et les échantillons;
0 ou d'un échantillon, on a S' = 8 et L' = 9.
est la composante de la variance due aux différences
U$
Degrés de liberté des laboratoires = L - 1 = 8
entre les laboratoires.
Degrés de liberté de l'interaction laboratoires x échan-
tillons : s'il n'y avait pas eu d'estimations, on aurait (9 - 1)
5.4.2 Espérance des carrés moyens lorsqu 'il y a des valeurs
(8 - 1) = 56. Mais, puisqu'il y a eu estimation d'une paire,
estimées
il vient : degrés de liberté de l'interaction laboratoires x
échantillons = 55. S'il n'y avait pas eu d'estimations, les
Lorsqu'il existe des valeurs estimées, les coefficients de U:
répétitions auraient eu 72 degrés de liberté. Mais, puisqu'il
et de U: sont modifiés dans l'expression des carrés moyens.
y a eu estimation d'une paire, cette valeur est réduite d'une
Les espérances mathématiques des carrés moyens deviennent
unité, donc elles ont 71 degrés de liberté.
Laboratoires : U: + a U: + /3 U;
5.3.4 Carrés moyens et analyse de variance
Laboratoires x échantillons : U; + y U:
Dans chaque cas, le carré moyen est égal a la somme des
carrés divisée par le nombre de degrés de liberté. Cela Répétitions : U;
à la table 9 d'analyse de variance.
conduit

TABLE 9
Origine de la Degrés de Somme des Carré
variation
liberté carrés moyen
Laboratoires
Somme des
ML
carrés des
laboratoires
Laboratoires (L'- 1) (S'- 1)
MLS
X échantillons - nombre de
paires estimées
Répétitions L'S' - nombre
Mr
de paires dans
lesquelles une
valeur ou les
deux ont été
dans lesquelles
estimées
nij est le nombre de résultats du iéme laboratoire
sur leième échantillon, s'il est essayé;
Ni est le nombre de résultats du ième laboratoire;
N' est le nombre total de résultats moins le nombre
de résultats rejetés;
Origine de la Degrés de Somme des Carré
variation liberté carrés moyen
K est le nombre decases L ~Scontenant un résultat.
Laboratoires 8 0,035 2 0,004 400
S'il n'existe pas de cases comportant seulement un seul
Laboratoires
0,114 3 I 0,002 078 I
résultat estimé, alors
X échantillons
I I 55 I
Répétitions 71 0,021 9 I 0,000308
a=y=2
IS0 4259-1979 (F)
NOTE - Le présent paragraphe est basé sur l'hypothèse d'après
L'estimation de la reproductibilité est égale au produit de
laquelle les échantillons et les laboratoires produisent des ((effets
l'écart-type de la reproductibilité par la valeur relative
aléatoires)).
au nombre de degrés de liberté de la reproductibilité ou
correspondant (voir annexe D, table 19). Une approxima-
tion du nombre de degrés de liberté de la variance de la
5.4.2.1 EXEMPLE
reproductibilité est donnée par la formule
Pour l'exemple étudié comportant huit échantillons et neuf
laboratoires,
(variance de la reproductibilité)2
V= . . . (14)
r:+-+- r$ r$
LI- 1 VLS V
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...