ISO 17201-1:2018
(Main)Acoustics - Noise from shooting ranges - Part 1: Determination of muzzle blast by measurement
Acoustics - Noise from shooting ranges - Part 1: Determination of muzzle blast by measurement
This document specifies a method to determine the acoustic source energy of the muzzle blast for calibres of less than 20 mm or explosive charges of less than 50 g TNT equivalent. It is applicable at distances where peak pressures less than 1 kPa (equivalent to a peak sound pressure level of 154 dB) are observed. The source energy, directivity of the source and their spectral structure determined by this procedure can be used as input data to sound propagation programmes, enabling the prediction of shooting noise in the neighbourhood of shooting ranges. Additionally, the data can be used to compare sound emission from different types of guns or different types of ammunition used with the same gun. This document is applicable to guns used in civil shooting ranges but it can also be applied to military guns. It is not applicable to the assessment of hearing damage or sound levels in the non-linear region. Suppressors and silencers are not taken into consideration in this document.
Acoustique — Bruit des stands de tir — Partie 1: Mesurage de l´énergie sonore en sortie de bouche
Le présent document spécifie une méthode permettant de déterminer l'énergie acoustique émise en sortie de bouche pour des armes de calibres inférieurs à 20 mm ou des charges explosives de moins de 50 g d'équivalent TNT. Elle est applicable à des distances où les valeurs de crête de pression acoustique observées sont inférieures à 1 kPa (équivalent à un niveau de pression acoustique de crête de 154 dB). L'énergie sonore émise, la directivité de la source et leur structure spectrale, déterminées par ce mode opératoire, peuvent être utilisées en tant que données d'entrée pour les modes de propagation du son permettant la prédiction du bruit généré par les tirs au voisinage des stands de tir. En outre, les données peuvent servir à comparer le bruit émis par différents types d'armes ou différents types de munitions utilisées par la même arme. Le présent document concerne les armes utilisées dans les stands de tir, mais elle peut également s'appliquer aux armes à usage militaire. Elle n'est pas applicable pour les besoins d'une évaluation des dommages auditifs ou des niveaux sonores dans la zone non linéaire. Les suppresseurs et silencieux ne sont pas pris en considération dans le présent document.
General Information
Relations
Overview
ISO 17201-1:2018 - Acoustics: Noise from shooting ranges - Part 1 specifies a standardized method for determining muzzle blast source energy by measurement. It applies to firearms with calibres less than 20 mm or explosive charges under 50 g TNT equivalent, and only at distances where peak pressures are below 1 kPa (≈154 dB peak sound pressure level). The measured source energy, directivity and spectral structure are intended as input to sound propagation models for predicting shooting noise in surrounding areas. The standard excludes suppressors/silencers and is not intended for assessing hearing damage or non-linear (very close-field) acoustic regions.
Key topics and technical requirements
- Scope limits: calibres < 20 mm; explosive charges < 50 g TNT equivalent; distances with peak SPL < 154 dB.
- Measured quantities: sound exposure, sound exposure level, peak sound pressure and spectral structure.
- Source characteristics: determination of source energy, angular directivity and interpolated angular distribution.
- Measurement procedure essentials: site selection and weather considerations, microphone and equipment placement, ground reflection correction, dealing with projectile sound, calibration and validation.
- Instrumentation standards referenced: IEC 60942 (sound calibrators), IEC 61672-1 (sound level meters) and ISO/IEC Guide 98-3 (GUM, measurement uncertainty).
- Quality control: calibration, validation routines and evaluation of measurement uncertainty.
- Reporting: standardized content for measurement reports to enable use in propagation models and comparative assessments.
Practical applications
- Provide input data for environmental noise models to predict shooting noise at neighborhood receptors.
- Compare sound emissions between different firearms or different ammunition types for the same gun.
- Support shooting range design and mitigation, zoning/permit assessments, and community noise evaluations.
- Applicable to civil shooting ranges and can also be applied to military guns when within the defined scope.
Who should use this standard
- Acoustic consultants and environmental noise modelers
- Shooting range designers and operators assessing off-site noise impact
- Ammunition and firearm manufacturers comparing muzzle-blast emissions
- Regulators and planners conducting noise assessments for permits and land-use decisions
- Military acoustics teams when measurements fall within the standard’s limits
Related standards
- Other parts of the ISO 17201 series (for broader shooting-range acoustics guidance)
- IEC 60942, IEC 61672-1 for measurement equipment conformity
- ISO/IEC Guide 98-3 (GUM) for expressing measurement uncertainty
Keywords: ISO 17201-1, muzzle blast measurement, shooting range noise, acoustics, sound exposure level, peak sound pressure, source energy, directivity, sound propagation models.
Frequently Asked Questions
ISO 17201-1:2018 is a standard published by the International Organization for Standardization (ISO). Its full title is "Acoustics - Noise from shooting ranges - Part 1: Determination of muzzle blast by measurement". This standard covers: This document specifies a method to determine the acoustic source energy of the muzzle blast for calibres of less than 20 mm or explosive charges of less than 50 g TNT equivalent. It is applicable at distances where peak pressures less than 1 kPa (equivalent to a peak sound pressure level of 154 dB) are observed. The source energy, directivity of the source and their spectral structure determined by this procedure can be used as input data to sound propagation programmes, enabling the prediction of shooting noise in the neighbourhood of shooting ranges. Additionally, the data can be used to compare sound emission from different types of guns or different types of ammunition used with the same gun. This document is applicable to guns used in civil shooting ranges but it can also be applied to military guns. It is not applicable to the assessment of hearing damage or sound levels in the non-linear region. Suppressors and silencers are not taken into consideration in this document.
This document specifies a method to determine the acoustic source energy of the muzzle blast for calibres of less than 20 mm or explosive charges of less than 50 g TNT equivalent. It is applicable at distances where peak pressures less than 1 kPa (equivalent to a peak sound pressure level of 154 dB) are observed. The source energy, directivity of the source and their spectral structure determined by this procedure can be used as input data to sound propagation programmes, enabling the prediction of shooting noise in the neighbourhood of shooting ranges. Additionally, the data can be used to compare sound emission from different types of guns or different types of ammunition used with the same gun. This document is applicable to guns used in civil shooting ranges but it can also be applied to military guns. It is not applicable to the assessment of hearing damage or sound levels in the non-linear region. Suppressors and silencers are not taken into consideration in this document.
ISO 17201-1:2018 is classified under the following ICS (International Classification for Standards) categories: 17.140.20 - Noise emitted by machines and equipment; 95.020 - Military in general; 97.220.10 - Sports facilities. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 17201-1:2018 has the following relationships with other standards: It is inter standard links to ISO 8655-7:2022, ISO 17201-1:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase ISO 17201-1:2018 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 17201-1
Second edition
2018-11
Acoustics — Noise from shooting
ranges —
Part 1:
Determination of muzzle blast by
measurement
Acoustique — Bruit des stands de tir —
Partie 1: Mesurage de l´énergie sonore en sortie de bouche
Reference number
©
ISO 2018
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Gun and ammunition . 5
4.1 General . 5
4.2 Gun . 5
4.3 Ammunition . 6
4.4 Ballistic parameters . 7
4.5 Test situation . 8
4.6 Other features . 8
5 Basic concept for measurement and analysis . 8
5.1 General . 8
5.2 Quantity to be measured .10
5.3 Angular source energy distribution level .10
5.4 Interpolated angular source energy distribution level .11
5.5 Source energy level .11
5.6 Directivity .11
6 Measurement site .12
6.1 Site .12
6.2 Weather conditions .12
7 Measurement planning .12
7.1 General remarks .12
7.2 Gun .12
7.3 Measurement position.12
7.4 Measurement equipment .13
7.5 Dealing with projectile sound .13
8 Calibration and validation .13
9 Measurement procedures .14
9.1 General .14
9.2 Ground reflection correction .14
10 Control of measurement layout .14
11 Measurement uncertainty .15
11.1 General .15
11.2 Empirical part .15
12 Report .16
Annex A (informative) Small arms glossary .17
Annex B (informative) Example .28
Annex C (informative) Guidance on the measurement uncertainty .36
Bibliography .39
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/iso/foreword .html.
This document was prepared by Technical Committee ISO/TC 43, Acoustics, Subcommittee SC 1, Noise.
This second edition cancels and replaces the first edition (ISO 17201-1:2005), which has been technically
revised. It also incorporates the Technical Corrigendum ISO 17201-1:2005/Cor 1:2009.
The main changes compared to the previous edition are as follows:
— the complete document has been editorially revised;
— 5.1, especially Figure 3 and the attached formula have been technically revised;
— Annex A (informative) "Small arms glossary" has been revised editorially;
— Annex B (informative) has been technically revised;
— references have been updated.
A list of all parts in the ISO 17201 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2018 – All rights reserved
Introduction
The initiative to prepare a standard on impulse noise from shooting ranges was taken by AFEMS, the
Association of European Manufacturers of Sporting Ammunition, in April 1996 by the submission of
a formal proposal to CEN. After consultation in CEN in 1998, CEN/TC 211, Acoustics asked ISO/TC 43/
SC 1, Noise to prepare the ISO 17201 series.
To obtain reliable data for the prediction of shooting sound levels at a reception point, the energy of
sound emission produced by the muzzle blast is needed. The muzzle blast is produced by the propellant
gas expelled from the barrel of a weapon; in most cases the gas has a supersonic fluid speed. Close to the
muzzle, the sound pressure is very high and cannot be described with linear acoustics. For the purpose
of this document, the non-linear region is defined by the observation of a peak sound pressure level
of 154 dB or more. This document defines how the sound source energy and directivity of the muzzle
blast can be obtained from the measurement of sound exposure levels and how these measurements
are to be carried out. The source energy, its directivity and spectral structure can be used as input for
sound propagation models for environmental noise assessment. This cannot be used for calculations of
sound exposure levels close to the weapon, for instance to estimate injury to people or animals.
INTERNATIONAL STANDARD ISO 17201-1:2018(E)
Acoustics — Noise from shooting ranges —
Part 1:
Determination of muzzle blast by measurement
1 Scope
This document specifies a method to determine the acoustic source energy of the muzzle blast for
calibres of less than 20 mm or explosive charges of less than 50 g TNT equivalent. It is applicable at
distances where peak pressures less than 1 kPa (equivalent to a peak sound pressure level of 154 dB)
are observed. The source energy, directivity of the source and their spectral structure determined by
this procedure can be used as input data to sound propagation programmes, enabling the prediction of
shooting noise in the neighbourhood of shooting ranges. Additionally, the data can be used to compare
sound emission from different types of guns or different types of ammunition used with the same gun.
This document is applicable to guns used in civil shooting ranges but it can also be applied to military
guns. It is not applicable to the assessment of hearing damage or sound levels in the non-linear region.
Suppressors and silencers are not taken into consideration in this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60942, Electroacoustics — Sound calibrators
IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications
ISO/IEC Guide 98-3, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in
me a s ur ement (GUM: 1995)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
3.1
sound pressure
p
difference between instantaneous total pressure and static pressure
Note 1 to entry: The sound pressure is expressed in pascals (Pa).
Note 2 to entry: Static pressure is the pressure that exists in the absence of sound waves.
Note 3 to entry: This definition applies to a medium allowing a non-zero mean flow in the atmosphere.
1)
Note 4 to entry: This definition is technically in accordance with ISO 80000-8:— , item 8-2.2.
Note 5 to entry: For the definition of "static pressure" see ISO 80000-8:—, item 8-2.1, with the difference of
allowing non-zero mean flow.
3.2
sound pressure level
L
p
ten times the logarithm to the base 10 of the ratio of the square of the root-mean-squared sound
pressure, p , to the square of a reference value, p
rms 0
p
rms
L =10lg dB (1)
p
p
Note 1 to entry: The sound pressure level is expressed in decibels (dB).
Note 2 to entry: The sound pressure is expressed in pascals (Pa).
Note 3 to entry: For sound in air and other gases, the reference sound pressure is given by p = 20 μPa.
Note 4 to entry: The sound pressure level can be frequency weighted and time weighted.
Note 5 to entry: This definition is technically in accordance with ISO 80000-8:—, item 8-15.
[SOURCE: ISO/TR 25417:2007, 2.2, modified — “the sound pressure, p” has been replaced with “the root-
mean-squared sound pressure, p ”; the wording “where the reference value, p , is 20 μPa” has been
rms 0
removed; the original NOTE 1 and 2 have been removed; Note 1, 2, 3, 4 and 5 to entry have been added.]
3.3
peak sound pressure
p
peak
maximum absolute sound pressure (3.1) during a stated time interval
Note 1 to entry: The peak sound pressure is expressed in pascals (Pa).
[SOURCE: ISO/TR 25417:2007, 2.4, modified — The word “greatest” has been replaced with “maximum”;
the word “certain” has been replaced with “stated”; NOTE 2 has been removed.]
3.4
peak sound pressure level
L
p,peak
ten times the logarithm to the base of 10 of the ratio of the square of the peak sound pressure, p (3.3)
peak
to the square of the reference value, p
p
peak
L =10lg dB (2)
p,peak
p
Note 1 to entry: The reference value is given by p = 20 μPa.
Note 2 to entry: The peak sound pressure level is expressed in decibels (dB).
Note 3 to entry: Peak sound pressure should be determined with a detector as defined in IEC 61672-1; IEC 61672-
2 only specifies the accuracy of a detector using C-weighting.
[SOURCE: ISO/TR 25417:2007, 2.5, modified — The wording “where the reference value, p , is 20 μPa”
has been removed; the original NOTE has been removed; Note 1, 2 and 3 to entry have been added.]
1) Under preparation.
2 © ISO 2018 – All rights reserved
3.5
event duration
T
stated time interval, long enough to encompass all significant sound of a stated event
Note 1 to entry: The event duration is expressed in seconds (s).
3.6
sound exposure
E
T
integral of the square of the sound pressure, p (3.1), over a stated time interval or event duration, T (3.5),
starting at t and ending at t
1 2
t
Ep= ()ttd (3)
T
∫
t
Note 1 to entry: The sound exposure is expressed in pascal-squared seconds (Pa s).
[SOURCE: ISO/TR 25417:2007, 2.6, modified — The original NOTE 1 to 4 have been removed; Note 1 to
entry has been added.]
3.7
sound exposure level
L
E,T
ten times the logarithm to the base 10 of the ratio of the sound exposure, E (3.6), to a reference value, E
T 0
E
T
L =10lg dB (4)
ET,
E
Note 1 to entry: The sound exposure level is expressed in decibels (dB).
Note 2 to entry: For sound in air and other gases, the reference value is given by E = 400 μPa s.
Note 3 to entry: This definition is technically in accordance with ISO 80000-8:—, item 8-17.
[SOURCE: ISO/TR 25417:2007, 2.7, modified — The original NOTE 1 to 3 have been removed; Note 1, 2
and 3 to entry have been added.]
3.8
source energy
Q
total sound source energy of the event
Note 1 to entry: The source energy is expressed in joules (J).
3.9
source energy level
L
Q
ten times the logarithm to the base 10 of the ratio of source energy, Q (3.8), to the reference source
energy, Q
Q
L =10lg dB (5)
Q
Q
Note 1 to entry: The source energy level is expressed in decibels (dB).
−12
Note 2 to entry: The reference value is given by Q = 10 J.
3.10
angular source energy distribution
S (α)
q
acoustic energy radiated from the muzzle blast into the far field, per unit solid angle
Note 1 to entry: The acoustic energy radiated by the muzzle blast within a narrow cone centred on the direction
α (3.14) is:
dQ
S α = (6)
()
q
dΩ
where
Q is the sound energy (3.8);
Ω is the solid angle expressed in steradians.
−1
Note 2 to entry: The angular source energy distribution, S (α), is expressed in joules per steradians (J sr ).
q
Note 3 to entry: Rotational symmetry is assumed around the line with α = 0.
3.11
interpolated angular source energy distribution
S α
()
q
continuous function in α of the source energy distribution S α (3.10) derived by using a defined
()
q
interpolation method
Note 1 to entry: The interpolated angular source energy distribution, S α , is expressed in joules per steradian
()
q
−1
(J sr ).
3.12
angular source energy distribution level
L (α)
q
angular source energy distribution (3.10), given by ten times the logarithm to base 10 of the ratio of
angular source energy distribution, S α (3.10) to the reference value, S
()
q q
S α
()
q
L α =10lg dB (7)
()
q
S
q
0
Note 1 to entry: The angular source energy distribution level, L (α), is expressed in decibels (dB).
q
−12 −1
Note 2 to entry: The reference value is given by S = 10 J sr .
q
3.13
interpolated angular source energy distribution level
L α
()
q
continuous function in α of the angular source energy distribution level, L (α) (3.12), derived by using a
q
defined interpolation method
Note 1 to entry: The interpolated angular source energy distribution level is expressed in decibels (dB).
3.14
angle alpha
α
angle between the line of fire and the line from the muzzle to the receiver
Note 1 to entry: The angle alpha is expressed in radians in all formulae.
4 © ISO 2018 – All rights reserved
3.15
angle beta
β
angle describing the rotation around the line of fire, anticlockwise from the view of the shooter
Note 1 to entry: The angle beta is expressed in radians in all formulae.
3.16
angle gamma
γ
angle describing the inclination of the line of fire from the horizontal plane
Note 1 to entry: The angle gamma is expressed in radians in all formulae.
Note 2 to entry: See Figure 3.
3.17
angle delta
δ
angle constituted by the projection of angle α on the horizontal plane
Note 1 to entry: The angle delta is expressed in radians in all formulae.
Note 2 to entry: See Figure 3.
3.18
directivity
D(α)
difference between the angular source energy distribution level (3.12) of the source under test and the
source energy distribution level of a monopole source with the same acoustic source energy
Note 1 to entry: The directivity is expressed in decibels (dB).
3.19
muzzle distance
r
m
distance measured from the muzzle to the microphone point
Note 1 to entry: The muzzle distance is expressed in metres (m).
Note 2 to entry: See Figure 3.
4 Gun and ammunition
4.1 General
The information given in 4.2 to 4.6 is needed to unambiguously define the weapon plus ammunition
combination for which the sound exposure level of the muzzle blast is estimated. All terms have the
meanings given in Reference [14] and Annex A.
4.2 Gun
The following features shall be stated:
— description or brand name;
— type of gun (shot gun, rifle, revolver, pistol, etc.);
— calibre or gauge;
— barrel bore;
— barrel length.
The following feature should be stated:
— number, type and disposition of barrels (side-to-side, superposed, drilling, etc.).
If present, special features such as the following shall be mentioned:
— flame shield;
— muzzle brake.
Special features such as the following should be mentioned:
— choke;
— reload system.
Figure 1 is a schematic view and gives the main terms used to describe the gun.
Key
1 stock 7 front sight
2 trigger guard 8 rear sight
3 trigger 9 bolt
4 magazine (inside) 10 receiver
5 barrel 11 safety lock
6 muzzle 12 bolt handle
Figure 1 — Main terms used to describe the gun (schematic view)
The main parts of smooth-bore barrel and a rifled barrel are given in Annex A.
4.3 Ammunition
The following information is needed and shall be stated:
— description or brand name;
— projectile calibre;
— projectile mass.
The following additional information should be given:
— type and mass or chemical energy of propellant;
— type of projectile (ball, sabot, pellets or blank).
6 © ISO 2018 – All rights reserved
In case of shot guns (shot pellets), the following additional information shall be stated:
— type, number, size and weight or type-number of pellets.
In case of shot guns (shot pellets), the following additional information should be stated:
— total length of the cartridge and the gauge;
— type of tube;
— type of wad;
— type of crimping.
Schematic views of ammunition for rifles, pistols and shotguns are shown in Figure 2, with names of
their main components.
Key
1 projectile (bullet) for rifle 6 tube
2 projectile (bullet) for pistol 7 shot pellets
3 case 8 plastic cylinder
4 propellant 9 wad
5 primer 10 case head
NOTE The measurements can be influenced by conditions such as the heating of the barrel during repetitive
shooting, the temperature, the humidity and the age of the ammunition.
Figure 2 — Schematic view of ammunition
4.4 Ballistic parameters
The muzzle speed (speed of the projectile at the muzzle), as a result of a gun/ammunition combination
as specified by the manufacturer, shall be stated.
Other available ballistic parameters should be stated.
NOTE Muzzle speed is a calculated value that corresponds to the speed of the projectile itself for rifles, or to
the speed of the centre of gravity of the cloud of pellets close to the muzzle of a shot gun.
4.5 Test situation
Any object that can cause reflections or shield the muzzle blast shall be mentioned. Such objects can be,
for example, a part of the weapon, the support of the weapon or part of this support. Also, the gunman
can be seen as a part of the weapon system that can shield the muzzle blast. All these elements, which
are commonly used under normal operation of the weapon, shall be present during the measurement
and shall be mentioned in the report. Other circumstances which can affect the noise source data shall
also be reported. The gun shall be positioned as it would be under normal operating conditions. If the
gun is put on a high support and fired with a rope, the shielding effect of the gunman is not taken into
account. Therefore, it should be ensured that the experimental set up is as close to normal operation
conditions as possible (see also 7.2).
4.6 Other features
All other information concerning the test conditions or anything that can affect measured source data
shall be reported.
EXAMPLES
— the barrel in use in the case of a combination firearm, if the barrels have different features, especially bore;
— special features, like muzzle brakes, etc.;
— storage conditions of ammunition (temperature, humidity, duration, etc.).
5 Basic concept for measurement and analysis
5.1 General
For the measurement of the muzzle blast, it is assumed that radiation of sound is rotationally
symmetrical around the line of fire. This assumption is used to define spherical coordinates, r , α and β
m
which are centred at the muzzle. The angles are defined in Clause 3.
As the muzzle blast can be directional, measurements may be carried out on a circle. The goal is to
measure the level and also the directivity pattern. An equal distance between measuring points makes
it easier to use interpolation algorithms to get a continuous function for directivity pattern.
The measurements and the analyses shall yield spectral information in at least octave bands (preferably
in one-third-octave-bands) from 31,5 Hz to 8 kHz.
The calculation method given in the 5.2 to 5.6 applies to broadband analysis as well as octave-band or
one-third-octave-band analysis.
8 © ISO 2018 – All rights reserved
a) Side view
b) Top view
Key
1 gun
2 muzzle
3 microphone
4 line of fire
5 ground plane
NOTE 1 All distances are measured in meters.
NOTE 2 The relation between these angles is given below:
rh+−tan γ h
()
()
pm g
coscαγ= os()cos δ
() ()
rh+−cos δ h
()
()
p mg
where
r is the projected distance on the ground plane from the muzzle to the microphone;
p
r is the distance from the muzzle to the microphone;
m
h is the height of the microphone above ground;
m
h is the height of the muzzle of the gun above ground.
g
Figure 3 — Angles γ and δ
5.2 Quantity to be measured
The basic quantity to be measured is the sound exposure level measured at a distance, r , and
m
angles α and β
pr ,,t αβ,
()
m
Lr ,,αβ =10lg ddt B (8)
()
E m
∫
T
I
pT
0 I
where
T is the time interval, in seconds;
I
T is the reference time interval, T =1s .
I I
0 0
For further notation see Figure 3 and definitions (Clause 3).
Assuming rotational symmetry, the sound exposure level is a function of r and α alone.
m
However, due to ground reflections, when measuring above ground, the sound exposure level, L , also
E
depends on β. The corrections to remove ground reflections are described in 9.2. After the corrections,
the sound exposure level is assumed to depend on distance, r , and angle α only.
m
5.3 Angular source energy distribution level
The angular source energy distribution levels, L (α ), are estimated on the basis of the sound exposure
q n
level measurements at N discrete angles, α , at the distance, r , by:
n m
LLαα= rA,1+ rA−+1dB rA++A (9)
() () () ()
qn Enmdiv matm mZ gr
where
A is a correction that accounts for the geometric spread:
div
r
m
A =10lg dB+11dB
div
(10)
r
with r = 1 m;
A is a correction for air absorption (see ISO 9613-1);
atm
A is a correction in order to obtain free field condition (see 9.2 and Reference [15]);
gr
NOTE This reference gives a simple algorithm to calculate the ground reflection of a spheri-
cal wave correctly, as described in Reference [16].
10 © ISO 2018 – All rights reserved
A is used to correct for non-standard meteorological conditions (see ISO 3741, ISO 3745 and
Z
ISO 9614-3):
BT
A =−10lg dB (11)
Z
BT
0
with
B is the air pressure under the condition of measurement;
B is the reference air pressure, B = 1 013 hPa;
0 0
T is the temperature under the condition of measurement;
T is the reference temperature, T = 296 K.
0 0
5.4 Interpolated angular source energy distribution level
In order to calculate the total source energy and to provide a continuous directivity function, a curve
fitting for the angular source energy distribution level is needed. The curve-fitting methods used shall
describe the periodic behaviour of the directivity function.
The angular source energy distribution level, L α , is obtained by interpolation and shall be reported
()
q
as follows:
N−1
Laαα=+ ajcos (12)
() ()
qj0 ∑
j=1
where N is the number of terms used to describe L α .
()
q
NOTE 1 This formulation corresponds to an approach according to Fourier without Sine terms. As rotational
symmetry is assumed, the Sine terms are zero.
NOTE 2 The parameters, a , can be obtained using Fourier Transformation, least-square fits or any other
j
interpolation method.
For an example, see Annex B.
5.5 Source energy level
The source energy level is calculated from the interpolated angular source energy distribution levels by:
2π
1 π 01, L α
()
q
L =10lg 10 rrsindαβ ddα B (13)
Q ∫ 0 0
∫
2 α=0
β=0
r
Since rotational symmetry is assumed, this can be written as:
π
01, L α
()
q
L =10lg21π 0 sindαα dB (14)
Q
∫
α=0
5.6 Directivity
The directivity D(α) of the muzzle blast is given by:
DLαα= −−L 10lg4πdB (15)
() ()
()
qQ
6 Measurement site
6.1 Site
The measurement site shall be reasonably level, homogeneous with respect to the ground impedance,
and free of objects that can cause reflections that affect the accuracy of the measurement.
EXAMPLE Examples of homogeneous grounds are:
— concrete,
— water,
— asphalt, and
— grass or sand.
6.2 Weather conditions
The average wind speed at 10 m height shall be less than 3 m/s.
The relative humidity shall be less than 95 %. The background level of wind-induced sound at the
microphone should not be so great that it interferes with the measured signal at any frequency of
interest.
7 Measurement planning
7.1 General remarks
Apart from the muzzle blast, the event signal may also include projectile sound, reflections from objects
and from the ground. When planning a measurement, it should be taken into consideration how these
“unwanted” contributions can be separated from the muzzle blast in the later data analysis. Commonly
used methods are the following.
a) Window technique: This technique is applicable for signals that arrive at the microphone
separated in time, where the width and position of the window is adjusted in such a way that
only the sound from the muzzle blast can be analysed. It is typically used for reflecting objects
and projectile sound. In a measurement layout with source and receiver heights that ensure a clear
separation of the direct and the reflected wave from the ground, it can also be used to exclude the
effect of ground reflections. In this case, it is A = 0.
gr
b) Ground impedance models: These models are used if the measured signal is a superposition of
the direct wave and the reflected wave from the ground. They yield a prediction of the ground
effect based on the reflection of a spherical wave at a complex impedance ground.
Other methods may also be used. The methods used shall be described.
7.2 Gun
The barrel should preferably be horizontal and at least 1,5 m above ground. In some directions, the
projectile sound wave and the muzzle blast can be separated by window techniques. For directions
where this is not possible, the correction may be computed. Projectile sound is also generated by
projectiles from shot guns and pistols as long as the speed of these projectiles is supersonic.
7.3 Measurement position
The measurement positions can be arranged in either a semicircle or a full circle. The angular
increment of angle α should preferably be regular. The angular increment should be 45° or less, see
also Clause 10. One measurement position should be close to the line of fire. Care shall be taken not
12 © ISO 2018 – All rights reserved
to choose measurement angles too close to the border of the projectile sound region. The difference
in the averaged broadband sound exposure level of the frequency range of interest between adjacent
measuring points shall be smaller than 5 dB. In order to reduce meteorological effects, the distance
between the source and measurement positions should be chosen to be as short as possible.
The microphone should normally be placed at a distance of at least 10 m up to 50 m to ensure that
the peak pressures do not exceed 1 kPa. It should be tested (considering the pressure limit of 1 kPa)
at which distance the prerequisite is fulfilled. By increasing the measurement and source heights, the
time delay between the direct and reflected signals can be increased.
7.4 Measurement equipment
Sound level meters and similar measurement instrumentation shall comply with the requirements for a
class 1 instrument as specified in IEC 61672-1.
Compliance with additional requirements for the measurement of impulsive noise is recommended.
Such requirements are specified in IEC 61672-1.
If a digital or analogue recording instrument is used for (intermediate) storage, it shall have an adequate
bandwidth and dynamic range.
The measurement equipment, and in particular the measurement microphones, shall be suitable for
measurement of high peak sound pressures. The potential to overload the microphones near to the
trajectory should be taken into account.
7.5 Dealing with projectile sound
Projectile sound occurs when the speed of a projectile is supersonic. This is typical for rifles, but can also
be observed with shotguns and pistols. Projectile sound only takes place in a distinct region in front of
the weapon (the Mach area). The border of the Mach area at the muzzle is defined by the angle, ξ :
c
ξ =arccos (16)
v
0
where
v is the projectile speed at the muzzle;
c is the speed of sound under the conditions of measurement.
For a measurement position where α equals ξ , the signals from the muzzle sound and the projectile
sound arrive at the same time and cannot be separated by time windowing. For measurement
angles with α smaller than ξ , the projectile sound always arrives first and can be separated by time
windowing. Care shall be taken not to choose a measurement position too close to the border of the
Mach area to enable the necessary time gap for a separation. In the case of noise from shotguns, the
time delay between the projectile sound and muzzle blast can be so small that time windowing or other
techniques cannot be applied. However, the projectile moves with supersonic speed for only a short
distance and its sound can be considered as coming from a point source. Therefore, the simultaneous
inclusion of the projectile´s sound with the muzzle blast is acceptable. An increase of delay between the
two signals may be achieved by increasing the measurement distance for the measurement positions
within the Mach area (for details see ISO 17201-4).
8 Calibration and validation
System calibration shall include the response of all cables, amplifiers and accessories to be used
when actual data are collected. Calibration shall be performed at appropriate times to ensure that
the time-averaged sound pressure level can be measured over the entire dynamic range within the
stated tolerance of the instrument. Acceptable acoustical calibration methods include the use of sound
calibrators, acoustical shock sources or static pressure devices. Electrical calibration means are
acceptable for field use, provided that acoustical calibration is accomplished before and after field use.
Electrical signals should be applied to the microphone input via a suitable adapter.
The complete measurement chain shall be calibrated by the user at regular intervals and at least before
and after a series of measurements at one frequency at least. The sound calibrator shall fulfil the
requirements for a class 1 sound calibrator as specified in IEC 60942 under the actual environmental
conditions.
The measurement instruments shall be checked regularly and shall be calibrated with traceability to a
national standard.
For further guidance in calibrating for measurement of impulses, see ISO 10843.
9 Measurement procedures
9.1 General
At least five measurements of the sound exposure shall be made at each microphone position. The
measured values of E (α, r ) are averaged arithmetically (which means that the sound exposure levels
T m
are averaged energetically). It is preferred that simultaneous measurements be made at all microphone
positions. Alternatively, measurements may be made sequentially but, as a minimum, two microphones
should be used with one microphone always remaining at the same position.
If the peak sound pressure level exceeds 154 dB at any of the microphone positions, the measurement
distance shall be increased. These peak sound pressure levels should preferably be read from the
time/pressure signal, where the error due to limited high-frequency response of the equipment can be
corrected.
9.2 Ground reflection correction
There are several methods to correct for the ground reflection. No corrections for ground reflection are
necessary when windowing techniques are applied. Otherwise, the resulting levels shall be corrected
to free-field conditions by applications of another suitable method (see, for example, Annex B). This
document requires that the method and the corrections be recorded. If a method other than the one
described in Annex B is used to determine the ground reflection, the value of A in Formula (9) shall be
gr
changed correspondingly.
10 Control of measurement layout
To determine whether or not the number of measurement points is sufficient, the following procedure
shall be applied.
(1)
Step 1: The source energy level, L , is calculated using the interpolated angular source energy
Q
distribution level as given in Formula (12):
π
01, L α
1 ()
()
q
L =10lg 21π 0 sindαα dB (17)
Q
∫
α=0
where the superscript 1 denotes this procedure.
14 © ISO 2018 – All rights reserved
(2)
Step 2: A source energy level, L , is calculated from the interpolated angular source energy
Q
distribution, S α , as follows:
()
q
π
2π
()2
L =10lg S ααsindα dB (18)
()
Qq
∫
Q
α=0
where the superscript 2 denotes this procedure;
S α is obtained with the same interpolation method used for the estimation of L α .
() ()
q q
(1) (2)
If the absolute value of the difference between L and L is 0,4 dB or less, the number of measured
Q Q
angular directions is considered to be sufficient:
() ()
LL−≤04,dB (19)
QQ
11 Measurement uncertainty
11.1 General
The measurement uncertainties associated with the source energy level and the directivity determined
in accordance with this document shall be evaluated, preferably in compliance with ISO/IEC Guide 98-3.
The uncertainties arise in part from variations between test sites, changes in atmospheric conditions,
geometry of the environment, acoustical properties of the ground, background noise, and the type
and calibration of instrumentation. They are also due to variations in experimental techniques,
including the number and location of microphone positions, sound source location and orientation, and
determination of the corrections. In addition, uncertainties can occur if measurements are taken too
close to the source; such uncertainties increase for smaller distances and lower frequencies.
The expanded measurement uncertainty together with the corresponding coverage factor shall be
stated for a coverage probability of 95 % as defined in ISO/IEC Guide 98-3.
Guidance on how to express the uncertainty is given in Annex C.
11.2 Empirical part
This document provides two quantities to express the muzzle blast: the source energy level and its
directivity. The contribution to the uncertainties from measurement as described above shall be
estimated from the variance, s of the directivity:
D
n m
s = LLαα− (20)
() ()
D qi qj, i
∑∑
nm⋅−N
i==11j
where
m is the number of repetitive measurements;
n is the number of measured directions;
is the measured angular source energy distribution level, j, in direction α ;
i
L α
()
qj, i
N is the number of used coefficients in Formula (12) (see 5.4).
The uncertainty contribution, Δ , of the directivity is given by:
D
st⋅ nm⋅−NP,
()
D
Δ = (21)
D
m
where
t is the student factor; see Table 1 below;
P is the coverage probability (chosen to be 0,05).
Table 1 — Distribution of t-values in consideration of the number of degrees of freedom
Number of Coverage probability, P
degrees of
%
freedom
68,27 95
1 1,84 12,71
5 1,11 2,57
10 1,05 2,23
20 1,03 2,09
40 1,01 2,02
NOTE See Reference [15].
For the source energ
...
NORME ISO
INTERNATIONALE 17201-1
Deuxième édition
2018-11
Acoustique — Bruit des stands de tir —
Partie 1:
Mesurage de l´énergie sonore en
sortie de bouche
Acoustics — Noise from shooting ranges —
Part 1: Determination of muzzle blast by measurement
Numéro de référence
©
ISO 2018
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2018
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2018 – Tous droits réservés
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Arme et munition . 5
4.1 Généralités . 5
4.2 Arme . 6
4.3 Munition . 7
4.4 Paramètres balistiques. 8
4.5 Contexte de l’essai . 8
4.6 Autres éléments (fonctions et dispositifs) . 9
5 Concept de base pour le mesurage et l’analyse . 9
5.1 Généralités . 9
5.2 Grandeur à mesurer .10
5.3 Niveau de distribution angulaire de l’énergie acoustique émise par la source .11
5.4 Niveau de distribution angulaire interpolée de l’énergie acoustique émise par la source 11
5.5 Niveau d’énergie acoustique émise par la source .12
5.6 Directivité .12
6 Site de mesurage .12
6.1 Site .12
6.2 Conditions météorologiques .12
7 Planification des mesurages .13
7.1 Observations d’ordre général .13
7.2 Arme .13
7.3 Position de mesure .13
7.4 Appareillage de mesure .14
7.5 Traitement du bruit émis par un projectile .14
8 Étalonnage et validation .14
9 Méthodes de mesure .15
9.1 Généralités .15
9.2 Correction de la réflexion par le sol .15
10 Contrôle de la configuration de mesurage.15
11 Incertitude de mesure .16
11.1 Généralités .16
11.2 Méthode empirique.16
12 Rapport.17
Annexe A (informative) Glossaire des armes légères.19
Annexe B (informative) Exemple .31
Annexe C (informative) Lignes directrices pour l’incertitude de mesure.39
Bibliographie .42
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos.
Le présent document a été élaboré par le comité technique ISO/TC 43, Acoustique, sous-comité SC 1, Bruit.
Cette deuxième édition annule et remplace la première édition (ISO 17201-1:2005), qui a fait l’objet d’une
révision technique. Elle comprend également le Corrigendum technique ISO 17201-1:2005/Cor 1:2009.
Les principales modifications par rapport à l’édition précédente sont les suivantes:
— révision rédactionnelle du document complet;
— révision technique de 5.1, en particulier de la Figure 3 et de la formule associée;
— révision rédactionnelle de l’Annexe A (informative) “Glossaire des armes légères”;
— révision technique de l’Annexe B (informative);
— mise à jour des références.
Une liste de toutes les parties de la série ISO 17201 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
iv © ISO 2018 – Tous droits réservés
Introduction
L’initiative d’élaborer une norme sur le bruit impulsionnel des stands de tir a été prise par l’AFEMS
(Association of European Manufacturers of Sporting Ammunition, l’association des fabricants
européens de munitions pour le tir sportif), en avril 1996, sous la forme d’une proposition formelle
au CEN. Après consultation au CEN en 1998, le CEN/TC 211, Acoustique, a demandé à l’ISO/TC 43/SC 1,
Bruit, de préparer la série de normes ISO 17201.
Afin d’obtenir des données fiables pour la prévision des niveaux de bruit émis par les tirs et perçus
à un point donné, il est nécessaire de déterminer l’énergie sonore d’émission en sortie de bouche.
La détonation à la bouche est produite par les gaz de la charge propulsive éjectés par le canon d’une
arme; dans la plupart des cas, le gaz est expulsé à une vitesse supersonique. À proximité de la bouche,
la pression acoustique est très élevée et ne peut être décrite en termes d’acoustique linéaire. Pour
les besoins du présent document, la zone non linéaire est définie grâce à l’observation d’un niveau
de pression acoustique de crête de 154 dB ou plus. Le présent document définit par quelle méthode
l’énergie sonore et la directivité en sortie de bouche peuvent être obtenues à partir du mesurage
des niveaux d’exposition sonore et de quelle manière ces mesurages doivent être effectués. L’énergie
acoustique émise, sa directivité et sa structure spectrale peuvent servir à l’établissement de modèles de
propagation du son pour l’évaluation du bruit ambiant. Elle ne peut pas être utilisée pour les calculs des
niveaux d’exposition sonore à proximité de l’arme, par exemple pour apprécier les lésions causées aux
personnes ou aux animaux.
NORME INTERNATIONALE ISO 17201-1:2018(F)
Acoustique — Bruit des stands de tir —
Partie 1:
Mesurage de l´énergie sonore en sortie de bouche
1 Domaine d'application
Le présent document spécifie une méthode permettant de déterminer l’énergie acoustique émise en
sortie de bouche pour des armes de calibres inférieurs à 20 mm ou des charges explosives de moins de
50 g d’équivalent TNT. Elle est applicable à des distances où les valeurs de crête de pression acoustique
observées sont inférieures à 1 kPa (équivalent à un niveau de pression acoustique de crête de 154 dB).
L’énergie sonore émise, la directivité de la source et leur structure spectrale, déterminées par ce mode
opératoire, peuvent être utilisées en tant que données d’entrée pour les modes de propagation du son
permettant la prédiction du bruit généré par les tirs au voisinage des stands de tir. En outre, les données
peuvent servir à comparer le bruit émis par différents types d’armes ou différents types de munitions
utilisées par la même arme.
Le présent document concerne les armes utilisées dans les stands de tir, mais elle peut également
s’appliquer aux armes à usage militaire. Elle n’est pas applicable pour les besoins d’une évaluation des
dommages auditifs ou des niveaux sonores dans la zone non linéaire.
Les suppresseurs et silencieux ne sont pas pris en considération dans le présent document.
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
IEC 60942, Électroacoustique — Calibreurs acoustiques
IEC 61672-1, Électroacoustique — Sonomètres — Partie 1: Spécifications
Guide ISO/IEC 98-3, Incertitude de mesure — Partie 3: Guide pour l’expression de l’incertitude de mesure
(GUM: 1995)
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https: //www .iso .org/obp
— IEC Electropedia: disponible à l’adresse http: //www .electropedia .org/
3.1
pression acoustique
p
différence entre la pression instantanée et la pression statique
Note 1 à l'article: La pression acoustique est exprimée en pascals (Pa).
Note 2 à l'article: La pression statique est la pression qui existe en l’absence de toute onde acoustique.
Note 3 à l'article: La présente définition s’applique à un milieu permettant un écoulement moyen non nul dans
l’atmosphère.
1)
Note 4 à l'article: La présente définition est techniquement conforme à l’ISO 80000-8:— , Article 8-2.2.
Note 5 à l'article: Pour la définition de la “pression statique”, voir l’ISO 80000-8:—, Article 8-2.1, avec la différence
qu’elle autorise un écoulement moyen non nul.
3.2
niveau de pression acoustique
L
p
dix fois le logarithme décimal du rapport du carré de la pression acoustique efficace, p , au carré de
rms
la valeur de référence, p
p
rms
L =10lg dB (1)
p
p
Note 1 à l'article: Le niveau de pression acoustique est exprimé en décibels (dB).
Note 2 à l'article: La pression acoustique est exprimée en pascals (Pa).
Note 3 à l'article: Pour le son se propageant dans l’air et d’autres gaz, la pression acoustique de référence est
donnée par p = 20 μPa.
Note 4 à l'article: Le niveau de pression acoustique peut être pondéré en fréquence ou en fonction du temps.
Note 5 à l'article: La présente définition est techniquement conforme à l’ISO 80000-8:—, Article 8-15.
[SOURCE: ISO/TR 25417:2007, 2.2, modifié — «la pression acoustique, p» a été remplacé par «la pression
acoustique efficace, p »; la formulation «où la valeur de référence, p , est 20 μPa» a été supprimée; les
rms 0
NOTES 1 et 2 d’origine ont été supprimées; les Notes 1, 2, 3, 4 et 5 à l’article ont été ajoutées.]
3.3
pression acoustique de crête
p
crête
pression acoustique (3.1) absolue maximale pendant un intervalle de temps déclaré
Note 1 à l'article: La pression acoustique de crête est exprimée en pascals (Pa).
[SOURCE: ISO/TR 25417:2007, 2.4, modifié — L’expression «plus grande» a été remplacée par
«maximale»; le mot «certain» a été remplacé par «déclaré»; la NOTE 2 a été supprimée.]
3.4
niveau de pression acoustique de crête
L
p,crête
dix fois le logarithme décimal du rapport du carré de la pression acoustique de crête, p (3.3), au
crête
carré de la valeur de référence, p
p
crête
L =10lg dB (2)
p,crête
p
Note 1 à l'article: La valeur de référence est donnée par p = 20 μPa.
Note 2 à l'article: Le niveau de pression acoustique de crête est exprimé en décibels (dB).
Note 3 à l'article: Il convient de déterminer la pression acoustique de crête avec un détecteur tel que défini dans
l’IEC 61672-1; l’IEC 61672-2 ne spécifie que l’exactitude d’un détecteur en utilisant une pondération C.
1) En cours d’élaboration.
2 © ISO 2018 – Tous droits réservés
[SOURCE: ISO/TR 25417:2007, 2.5, modifié — La formulation «où la valeur de référence, p , est 20 μPa»
a été supprimée; la NOTE d’origine a été supprimée; les Notes 1, 2 et 3 à l’article ont été ajoutées.]
3.5
durée d’un événement
T
intervalle de temps déclaré suffisamment long pour englober l’ensemble du son significatif d’un
événement spécifié
Note 1 à l'article: La durée d’un événement est exprimée en secondes (s).
3.6
exposition sonore
E
T
intégrale du carré de la pression acoustique, p (3.1), sur un intervalle de temps ou une durée d’événement,
T (3.5), déclaré commençant à t et finissant à t
1 2
t
Ep= ()ttd (3)
T
∫
t
Note 1 à l'article: L’exposition sonore est exprimée en pascals carrés·secondes (Pa s).
[SOURCE: ISO/TR 25417:2007, 2.6, modifié — Les NOTES 1 à 4 d’origine ont été supprimées; la Note 1 à
l’article a été ajoutée.]
3.7
niveau d’exposition sonore
L
E,T
dix fois le logarithme décimal du rapport de l’exposition sonore, ET (3.6), à une valeur de référence, E
E
T
L =10lg dB (4)
ET,
E
Note 1 à l'article: Le niveau d’exposition sonore est exprimé en décibels (dB).
Note 2 à l'article: Pour le son se propageant dans l’air et d’autres gaz, la valeur de référence est donnée par
E = 400 μPa s.
Note 3 à l'article: La présente définition est techniquement conforme à l’ISO 80000-8:—, Article 8-17.
[SOURCE: ISO/TR 25417:2007, 2.7, modifié — Les NOTES 1 à 3 d’origine ont été supprimées; les Notes 1,
2 et 3 à l’article ont été ajoutées.]
3.8
énergie acoustique émise par la source
Q
énergie acoustique totale produite pendant la durée de l’événement
Note 1 à l'article: L’énergie acoustique émise par la source est exprimée en joules (J).
3.9
niveau d’énergie acoustique émise par la source
L
Q
dix fois le logarithme décimal du rapport de l’énergie acoustique émise par la source, Q (3.8), à l’énergie
acoustique de référence émise par la source, Q
Q
L =10lg dB (5)
Q
Q
0
Note 1 à l'article: Le niveau d’énergie acoustique émise par la source est exprimé en décibels (dB).
−12
Note 2 à l'article: La valeur de référence est donnée par Q = 10 J.
3.10
distribution angulaire de l’énergie acoustique émise par la source
S (α)
q
énergie acoustique rayonnée par la détonation en champ lointain par unité d’angle solide
Note 1 à l'article: L’énergie acoustique rayonnée par la détonation dans les limites d’un cône étroit centré sur la
direction α (3.14) est:
dQ
S α = (6)
()
q
dΩ
où
Q est l’énergie acoustique (3.8);
Ω est l’angle solide exprimé en stéradians.
Note 2 à l'article: La distribution angulaire de l’énergie acoustique émise par la source, S (α), est exprimée en
q
−1
joules par stéradian (J sr ).
Note 3 à l'article: Il est supposé une symétrie de révolution autour de la ligne de tir avec α = 0.
3.11
distribution angulaire interpolée de l’énergie acoustique émise par la source
S α
()
q
fonction continue en α de la distribution de l’énergie acoustique émise par la sourceS α (3.10) dérivée
()
q
en utilisant une méthode d’interpolation définie
Note 1 à l'article: La distribution angulaire interpolée de l’énergie acoustique émise par la source, S α , est
()
q
−1
exprimée en joules par stéradian (J sr ).
3.12
niveau de distribution angulaire de l’énergie acoustique émise par la source
L (α)
q
distribution angulaire de l’énergie acoustique émise par la source (3.10), donnée par dix fois le logarithme
décimal du rapport de la distribution angulaire de l’énergie acoustique émise par la source, S α (3.10) à
()
q
la valeur de référence, S
q
S α
()
q
L α =10lg dB (7)
()
q
S
q
Note 1 à l'article: Le niveau de distribution angulaire de l’énergie acoustique émise par la source, L (α), est
q
exprimé en décibels (dB).
−12 −1
Note 2 à l'article: La valeur de référence est donnée par S = 10 J sr .
q
3.13
niveau de distribution angulaire interpolée de l’énergie acoustique émise par la source
L α
()
q
fonction continue en α du niveau de distribution angulaire de l’énergie acoustique émise par la source,
L (α) (3.12), dérivée en utilisant une méthode d’interpolation définie
q
Note 1 à l'article: Le niveau de distribution angulaire interpolée de l’énergie acoustique émise par la source est
exprimé en décibels (dB).
4 © ISO 2018 – Tous droits réservés
3.14
angle alpha
α
angle situé entre la ligne de tir et la ligne reliant la bouche au récepteur
Note 1 à l'article: L’angle alpha est exprimé en radians dans toutes les formules.
3.15
angle bêta
β
angle décrivant la rotation autour de la ligne de tir, dans le sens antihoraire, tel que vu par le tireur
Note 1 à l'article: L’angle bêta est exprimé en radians dans toutes les formules.
3.16
angle gamma
γ
angle décrivant l’inclinaison de la ligne de tir par rapport au plan horizontal
Note 1 à l'article: L’angle gamma est exprimé en radians dans toutes les formules.
Note 2 à l'article: Voir Figure 3.
3.17
angle delta
δ
angle formé par la projection de l’angle α sur le plan horizontal
Note 1 à l'article: L’angle delta est exprimé en radians dans toutes les formules.
Note 2 à l'article: Voir Figure 3.
3.18
directivité
D(α)
différence entre le niveau de distribution angulaire de l’énergie acoustique émise par la source (3.12) de la
source soumise à essai et le niveau de distribution de l’énergie acoustique d’une source monopole ayant
la même énergie acoustique que la source
Note 1 à l'article: La directivité est exprimée en décibels (dB).
3.19
distance à la bouche
r
m
distance mesurée de la bouche au point d’installation du microphone
Note 1 à l'article: La distance à la bouche est exprimée en mètres (m).
Note 2 à l'article: Voir Figure 3.
4 Arme et munition
4.1 Généralités
Afin de définir sans équivoque la combinaison arme plus munition pour laquelle le niveau d’exposition
sonore en sortie de bouche est estimé, les informations données de 4.2 à 4.6 sont nécessaires. Tous les
termes correspondent aux sens qui leur sont donnés dans la Référence [14] et dans l’Annexe A.
4.2 Arme
Les éléments suivants doivent être déclarés:
— description ou nom commercial;
— type d’arme (fusil de chasse, carabine, revolver, pistolet, etc.);
— calibre;
— âme du canon;
— longueur du canon.
Il convient de déclarer les éléments suivants:
— nombre, type et disposition des canons (jumelés juxtaposés ou superposés, à trois canons
[drilling], etc.).
Le cas échéant, les éléments spécifiques tels que les suivants doivent être mentionnés:
— pare-flammes;
— frein de bouche.
Il convient de mentionner les éléments spécifiques tels que les suivants:
— choke (étranglement);
— système de rechargement.
La Figure 1 est une représentation schématique donnant les principaux termes utilisés pour décrire
l’arme.
Légende
1 crosse 7 guidon
2 pontet 8 hausse
3 détente 9 culasse
4 magasin (à l’intérieur) 10 boîte de culasse
5 canon 11 cran de sûreté
6 bouche 12 levier de culasse
Figure 1 — Principaux termes utilisés pour décrire l’arme (représentation schématique)
L’Annexe A présente les principaux éléments d’un canon à âme lisse et d’un canon rayé.
6 © ISO 2018 – Tous droits réservés
4.3 Munition
Les informations suivantes sont nécessaires et doivent être déclarées:
— description ou nom commercial;
— calibre du projectile;
— masse du projectile.
Il convient de donner les informations supplémentaires suivantes:
— type et masse ou énergie chimique de la charge propulsive;
— type de projectile (balle, sabot, grenaille ou cartouche à blanc).
Dans le cas des fusils de chasse (charge de grenaille), les informations supplémentaires suivantes
doivent être déclarées:
— type, nombre, taille et poids ou numéro de la grenaille.
Dans le cas des fusils de chasse (charge de grenaille), il convient de déclarer les informations
supplémentaires suivantes:
— longueur totale de la cartouche et calibre;
— type de tube;
— type de bourre;
— type de sertissage.
Des vues schématiques de munitions pour carabines, pistolets et fusils de chasse sont représentées à la
Figure 2 avec leurs principaux éléments constitutifs.
Légende
1 projectile (balle) pour carabine 6 tube
2 projectile (balle) pour pistolet 7 charge de grenaille
3 douille 8 étui cylindrique
4 poudre 9 bourre
5 amorce 10 culot de douille
NOTE Les mesurages peuvent être influencés par certains facteurs tels que le réchauffement du canon suite
à des tirs à répétition, la température, l’humidité et l’ancienneté de la munition.
Figure 2 — Représentation schématique de munitions
4.4 Paramètres balistiques
La vitesse initiale (vitesse du projectile à la bouche), comme étant le résultat de la combinaison arme/
munition, telle que spécifiée par le fabricant, doit être déclarée.
Il convient de déclarer les autres paramètres balistiques disponibles.
NOTE La vitesse initiale est une valeur calculée correspondant à la vitesse du projectile lui-même pour les
carabines ou à la vitesse de déplacement du centre de gravité du nuage de plombs à proximité de la bouche d’un
fusil de chasse.
4.5 Contexte de l’essai
Tout objet pouvant provoquer des réflexions ou faire écran à la détonation doit être mentionné. Par
exemple, une partie de l’arme, le support de l’arme ou un élément de ce support peuvent constituer de
tels objets. Le tireur peut être considéré comme faisant partie du système d’arme pouvant faire écran
à la détonation. Tous ces éléments, qui sont généralement utilisés dans des conditions normales de
fonctionnement de l’arme, doivent être disponibles lors du mesurage et doivent être mentionnés dans le
rapport. D’autres circonstances susceptibles d’affecter les données relatives à la source de bruit doivent
également être consignées dans le rapport. L’arme doit être positionnée telle qu’elle devrait l’être dans
ses conditions normales de fonctionnement. Si l’arme est posée sur un support surélevé et que la mise à
feu est effectuée à distance à l’aide d’une corde, l’effet écran du tireur n’est pas pris en considération. Par
conséquent, il convient de s’assurer que la configuration expérimentale se rapproche le plus possible
des conditions normales de fonctionnement (voir aussi 7.2).
8 © ISO 2018 – Tous droits réservés
4.6 Autres éléments (fonctions et dispositifs)
Toute autre information concernant les conditions de déroulement de l’essai ou susceptible d’influer sur
les données relatives à la source de bruit mesurée doit être consignée dans le rapport.
EXEMPLES
— Le canon utilisé, dans le cas d’une arme à feu à tubes mixtes, lorsque les canons sont équipés de différents
dispositifs, et tout particulièrement l’âme.
— Les dispositifs spéciaux, tels que freins de bouche, etc.
— Les conditions de stockage des munitions (température, humidité, durée, etc.).
5 Concept de base pour le mesurage et l’analyse
5.1 Généralités
Pour le mesurage de la détonation en sortie de bouche, la propagation du son est supposée s’effectuer
selon une symétrie de révolution autour de la ligne de tir. Cette hypothèse sert à définir des coordonnées
sphériques, r , α et β, centrées par rapport à la bouche. Les angles sont définis dans l’Article 3.
m
La détonation pouvant se propager de manière directionnelle, les mesurages peuvent être effectués sur
un cercle. Le but est d’en mesurer le niveau ainsi que le diagramme de directivité. Une distance égale
entre points de mesurages facilite l’utilisation d’algorithmes d’interpolation permettant d’obtenir une
fonction continue pour le diagramme de directivité.
Les mesurages et les analyses doivent permettre de fournir des informations d’ordre spectral au moins
dans des bandes d’octave (de préférence dans des bandes de tiers d’octave) de 31,5 Hz à 8 kHz.
La méthode de calcul donnée de 5.2 à 5.6 s’applique à une analyse à large bande ainsi qu’à une analyse
par bandes d’octave ou par bandes de tiers d’octave.
a) Vue de côté
b) Vue de dessus
Légende
1 arme
2 bouche
3 microphone
4 ligne de tir
5 plan du sol
NOTE 1 Toutes les distances sont mesurées en mètres.
NOTE 2 La relation entre ces angles est donnée ci-dessous:
rh+−tan γ h
()
()
pm g
cosc()αγ= os()cos()δ
rh+−cos ()δ h
()
p mg
où
r est la distance projetée sur le plan du sol entre la bouche et le microphone;
p
r est la distance entre la bouche et le microphone;
m
h est la hauteur à laquelle est placé le microphone par rapport au sol;
m
h est la hauteur à laquelle est située la bouche de l’arme par rapport au sol.
g
Figure 3 — Angles γ et δ
5.2 Grandeur à mesurer
La grandeur de base à mesurer est le niveau d’exposition sonore mesuré à une distance r et selon les
m
angles α et β.
pr ,,t αβ,
()
m
Lr ,,αβ =10lg ddt B (8)
()
E m
∫
T
I pT
0 I
où
T est l’intervalle de temps, en secondes;
I
T est l’intervalle de temps de référence, T =1s .
I I
0 0
10 © ISO 2018 – Tous droits réservés
Pour les autres notations, voir Figure 3 et les définitions (Article 3).
En supposant que le son se propage selon une symétrie de révolution, le niveau d’exposition sonore est
fonction de r et α uniquement.
m
Toutefois, en raison des réflexions par le sol, lors de mesurages effectués au-dessus du sol, le niveau
d’exposition sonore, L , dépend également de β. Les corrections permettant d’éliminer les réflexions
E
par le sol sont décrites en 9.2. Après correction, le niveau d’exposition sonore est supposé dépendre de
la distance, r , et de l’angle α uniquement.
m
5.3 Niveau de distribution angulaire de l’énergie acoustique émise par la source
Les niveaux de distribution angulaire de l’énergie acoustique émise par la source, L (α ), sont estimés
q n
sur la base des mesurages du niveau d’exposition sonore à N angles discrets, α , à la distance r par:
n m
LLαα= rA,1+ rA−+1dB rA++A (9)
() () () ()
qn Enmdiv matm mz gr
où
A est une correction qui compense la dispersion géométrique:
div
r
m
A =10lg dB+11dB
div
2 (10)
r
0
avec r = 1 m;
A est une correction tenant compte de l’absorption par l’air (voir l’ISO 9613-1);
atm
A est une correction destinée à obtenir des conditions en champ libre (voir 9.2 et la Réfé-
gr
rence [15]).
NOTE Cette référence donne un algorithme simple permettant de calculer correctement la
réflexion par le sol d’une onde sphérique, tel que décrit dans la Référence [16].
A est un paramètre utilisé pour la correction en cas de conditions météorologiques non nor-
Z
malisées (voir l’ISO 3741, l’ISO 3745 et l’ISO 9614-3):
BT
A =−10lg dB (11)
Z
BT
0
avec
B est la pression atmosphérique dans les conditions de réalisation du mesurage;
B est la pression atmosphérique de référence, B = 1 013 hPa;
0 0
T est la température dans les conditions de réalisation du mesurage;
T est la température de référence, T = 296 K.
0 0
5.4 Niveau de distribution angulaire interpolée de l’énergie acoustique émise par la
source
Afin de calculer l’énergie acoustique totale émise par la source et de fournir une fonction continue
de directivité, un ajustement de la courbe de niveau de distribution angulaire de l’énergie acoustique
émise par la source est nécessaire. Les méthodes d’ajustement de courbe utilisées doivent décrire le
comportement périodique de la fonction de directivité.
Le niveau de distribution angulaire de l’énergie acoustique émise par la source, L α , est obtenu par
()
q
interpolation et doit être consigné dans le rapport de la manière suivante:
N−1
Laαα=+ ajcos (12)
() ()
qj0 ∑
j=1
où N est le nombre de termes utilisés pour décrire L α .
()
q
NOTE 1 Cette formulation correspond à une approche conforme à celle de Fourier, mais sans termes
sinusoïdaux. Une symétrie de révolution suppose que les termes sinusoïdaux sont égaux à zéro.
NOTE 2 Les paramètres, a , peuvent être obtenus en utilisant la transformation de Fourier, les ajustements par
j
les moindres carrés ou toute autre méthode d’interpolation.
Un exemple est donné dans l’Annexe B.
5.5 Niveau d’énergie acoustique émise par la source
Le niveau d’énergie acoustique émise par la source est calculé à partir des niveaux de distribution
angulaire interpolée de l’énergie acoustique émise par la source, par:
2π
1 π 01, L α
()
q
L =10lg 10 rrsindαβ ddα B (13)
Q ∫ 0 0
∫
α=0
β=0
r
Étant donné la symétrie de révolution supposée, la formule peut s’écrire:
π
01, L ()α
q
L =10lg21π 0 sindαα dB (14)
Q
∫
α=0
5.6 Directivité
La directivité D(α) de la détonation en sortie de bouche est donnée par:
DLαα= −−L 10lg4πdB (15)
() ()
()
qQ
6 Site de mesurage
6.1 Site
Le site de mesurage doit être raisonnablement plan, homogène eu égard à l’impédance acoustique du
sol et exempt de tout objet pouvant provoquer des réflexions de nature à fausser l’exactitude de mesure.
EXEMPLE Exemples de sols homogènes:
— béton;
— eau;
— asphalte, et
— gazon ou sable.
6.2 Conditions météorologiques
La vitesse moyenne du vent à 10 m de hauteur doit être inférieure à 3 m/s.
12 © ISO 2018 – Tous droits réservés
L’humidité relative doit être inférieure à 95 %. Il convient que le niveau du bruit de fond généré par
le vent, à l’emplacement du microphone, ne soit pas assez fort pour parasiter le signal mesuré à toute
fréquence représentative.
7 Planification des mesurages
7.1 Observations d’ordre général
Outre la détonation en sortie de bouche, l’environnement acoustique peut également inclure un son
émis par le départ d’un projectile, des réflexions par des objets et par le sol. Lors de la planification d’un
mesurage, il convient de prendre en considération la manière selon laquelle ces éléments «indésirables»
peuvent être séparés de la détonation en sortie de bouche dans l’analyse ultérieure des données. Les
méthodes utilisées en règle générale sont les suivantes.
a) Technique de fenêtrage: cette technique est applicable aux signaux qui parviennent au microphone
décalés dans le temps, où la largeur et la position de la fenêtre sont ajustées de manière à ne pouvoir
analyser que le bruit de la détonation en sortie de bouche. Elle constitue une méthode type utilisée
pour le bruit émis par les objets réfléchissants et les projectiles. Lors d’un mesurage, la disposition
de la source et du récepteur à certaines hauteurs permet une nette séparation entre l’onde directe
et celle réfléchie par le sol et peut également servir à éliminer l’effet des réflexions par le sol. Dans
ce cas, A = 0.
gr
b) Modèles d’impédance acoustique du sol: ces modèles sont utilisés lorsque le signal mesuré est
une superposition de l’onde directe et de l’onde réfléchie par le sol. Ils permettent une prédiction de
l’effet de sol fondée sur la réflexion d’une onde sphérique sur un terrain à impédance complexe.
D’autres méthodes peuvent être également utilisées. Les méthodes utilisées doivent être décrites.
7.2 Arme
Il convient que le canon soit positionné de préférence horizontalement et à une hauteur d’au moins 1,5 m
au-dessus du sol. Dans certaines directions, l’onde sonore générée par le projectile et la détonation en
sortie de bouche peuvent être discriminées par des techniques de fenêtrage. Pour les directions où cela
n’est pas possible, la correction peut être calculée. Un bruit émis par le projectile est également généré
par des projectiles tirés à partir de fusils de chasse et de pistolets, tant que la vitesse de ces projectiles
est supersonique.
7.3 Position de mesure
Les positions de mesure peuvent être disposées soit en demi-cercle, soit en cercle. Il convient de
préférence d’incrémenter l’angle α de manière régulière. Il convient que l’incrémentation angulaire soit
inférieure ou égale à 45°; voir également l’Article 10. Il convient que la position de mesure soit proche de
la ligne de tir. Il est nécessaire de faire attention à ne pas choisir des angles de mesure trop proches de
la zone limite de propagation du bruit émis par le projectile. La différence de niveau d’exposition sonore
moyennée à large bande du domaine de fréquence représentatif entre points de mesure adjacents doit
être inférieure à 5 dB. Afin de réduire les effets météorologiques, il convient de choisir une distance qui
soit la plus courte possible entre la source et les positions de mesure.
Il convient en règle générale de placer le microphone à une distance d’au moins 10 m jusqu’à 50 m
pour être sûr d’obtenir des valeurs de crête de pression acoustique n’excédant pas 1 kPa. Il convient de
déterminer par des essais (compte tenu de la pression acoustique limite de 1 kPa) la distance à laquelle
les conditions préalables requises sont satisfaites. En augmentant les hauteurs auxquelles sont placés
le point de mesure et la source, il est possible d’accentuer le décalage dans le temps entre les signaux
directs et réfléchis.
7.4 Appareillage de mesure
Les sonomètres et les instruments de mesure similaires doivent être conformes aux exigences relatives
à un instrument de classe 1, telles que spécifiées dans l’IEC 61672-1.
Pour le mesurage du bruit impulsionnel, la conformité aux exigences additionnelles est recommandée.
Ces exigences sont spécifiées dans l’IEC 61672-1.
Lorsqu’un instrument d’enregistrement numérique ou analogique est utilisé pour l’archivage
(intermédiaire), il doit disposer d’une bande passante et d’une gamme dynamique adéquates.
L’appareillage de mesure, et en particulier les microphones de mesure, doit être adapté et capable de
mesurer des pressions acoustiques de crête élevées. Il convient de prendre en compte la possibilité de
surcharge des microphones proches de la trajectoire.
7.5 Traitement du bruit émis par un projectile
Le bruit émis par un projectile est perceptible lorsque la vitesse du projectile est supersonique. Cela
est caractéristique pour les carabines, mais peut être également observé sur les fusils de chasse et les
pistolets. Le bruit émis par un projectile se situe dans une zone distincte à l’avant de l’arme (la zone de
Mach). La limite de la zone de Mach au niveau de la bouche est définie par l’angle ξ :
c
ξ =arccos (16)
v
0
où
v est la vitesse du projectile en sortie de bouche;
c est la vitesse du son dans les conditions de réalisation du mesurage.
Pour une position de mesure où l’angle α est égal à ξ , les signaux correspondant au bruit accompagnant
la détonation et le projectile en sortie de bouche parviennent en même temps et ne peuvent être
discriminés par un fenêtrage temporel. Pour une position angulaire de mesure où l’angle α est plus petit
que ξ , le bruit accompagnant le projectile parvient toujours en premier et peut être discriminé par un
fenêtrage temporel. Il est nécessaire de veiller à ne pas choisir une position de mesure trop proche de
la limite de la zone de Mach afin de prévoir l’intervalle de temps nécessaire à la séparation des deux
signaux. Pour le bruit émis par des fusils de chasse, le décalage temporel entre le bruit accompagnant le
projectile et celui induit par la détonation en sortie de bouche peut être tellement faible que le fenêtrage
temporel ou toute autre technique ne peut pas être appliqué. Cependant, puisque le projectile se déplace
à une vitesse supersonique uniquement sur une courte distance, le bruit qui l’accompagne peut être
considéré comme arrivant d’une source ponctuelle. Par conséquent, l’inclusion simultanée du bruit
accompagnant les projectiles avec la détonation en sortie de bouche est admise. Une augmentation du
décalage temporel entre les deux signaux peut être obtenue par un accroissement de la distance de
mesure pour les positions de mesure dans la zone de Mach (pour les détails, voir l’ISO 17201-4).
8 Étalonnage et validation
L’étalonnage du système doit s’étendre à tous les câbles, amplificateurs et accessoires à mettre en
œuvre lors de la collecte de données réelles. L’étalonnage doit être effectué à des périodes adéquates
afin de permettre le mesurage du niveau de pression acoustique temporel moyen sur l’ensemble de
la gamme dynamique dans les limites de tolérance déclarées de l’instrument. Les méthodes admises
d’étalonnage acoustique prévoient l’utilisation de calibreurs acoustiques, de sources
...
ISO 17201-1:2018 is a standard that defines a method for measuring the acoustic source energy of the muzzle blast from smaller calibers and explosives. This method is applicable when the peak pressures are less than 1 kPa and can be used to predict shooting noise near shooting ranges. The data obtained can also be used to compare sound emission from different types of guns or different ammunition used with the same gun. This standard is applicable to both civil and military guns but does not assess hearing damage or sound levels in the non-linear region. Suppressors and silencers are not considered in this standard.
The ISO 17201-1:2018 standard provides a method for determining the acoustic energy produced by the muzzle blast of firearms with calibers less than 20 mm or explosive charges less than 50 g TNT equivalent. This method is suitable for distances where peak pressures are below 1 kPa, which corresponds to a peak sound pressure level of 154 dB. The resulting data can be used to predict shooting noise in the vicinity of shooting ranges and compare the sound emissions of different types of guns or ammunition. The standard is applicable to both civilian and military guns but does not assess hearing damage or sound levels in the nonlinear range. It also does not include suppressors or silencers in its considerations.
記事のタイトル:ISO 17201-1:2018 - 音響 - 射撃場からの騒音 - 第1部:計測によるマズルブラストの決定 記事の内容:この文書は、直径20mm未満の銃口とTNT換算50g未満の爆薬のマズルブラストの音響源エネルギーを決定する方法を規定しています。ピーク圧力が1kPa未満(ピーク音圧レベル154dBに相当)の距離で適用されます。この手続きによって決定された音源エネルギー、音源の指向性、およびその周波数構造は、音の伝播プログラムの入力データとして使用され、射撃場周辺の射撃騒音を予測することができます。また、得られたデータは、同じ銃で使用される異なるタイプの銃弾や異なるタイプの銃からの音響放射を比較するためにも使用できます。この規格は民間の射撃場で使用される銃に適用することができますが、軍用銃にも適用することができます。この文書は非線形領域での聴覚損傷や音響レベルの評価には適用されません。消音装置やサイレンサーはこの文書では考慮されていません。
기사 제목: ISO 17201-1:2018 -음향학- 사격장으로부터의 소음- 제1부: 측정에 의한 총구 폭발력 결정 기사 내용: 이 문서는 20mm 미만의 총구 또는 50g TNT 동등의 폭발물에 대한 총구 폭발력의 음향 원천 에너지를 결정하기 위한 방법을 규정합니다. 이는 최대 압력이 1 kPa(최대음압수준 154dB에 해당) 이하인 거리에서 적용됩니다. 이 절차에 의해 결정된 원천 에너지, 원본의 직접성 및 스펙트럼 구조는 음향 전파 프로그램에 입력 데이터로 사용될 수 있으며, 측사장 근처에서의 사격소음을 예측할 수 있도록 합니다. 또한 동일한 총에서 사용되는 다른 종류의 총알이나 탄약의 사운드 배출을 비교하는 데에도 사용될 수 있습니다. 이 문서는 시민 사격장에서 사용되는 총기에 적용되지만, 군용 총기에도 적용될 수 있습니다. 이 문서는 비선형 영역에서의 청력 손상 평가나 소음 수준에는 적용되지 않으며, 소음기나 소음 억제 장치는 고려되지 않습니다.
기사 제목: ISO 17201-1:2018 - 음향학 - 사격장에서의 소음 - 일부 1편: 측정을 통한 총열 폭발력의 결정 기사 내용: 이 문서는 20mm 미만의 총구와 50g TNT 동등물질 미만의 폭발물에 대한 총열 폭발력의 음향 원천 에너지를 결정하기 위한 방법을 명시한다. 최대 압력이 1 kPa 이하(최대 음압 단계 154 dB에 해당)인 거리에서 적용 가능하다. 이 절차에 의해 결정된 원천 에너지, 원천의 직항성 및 그들의 주파수 구조는 소리 전파 프로그램에 입력 데이터로 사용될 수 있어, 사격장 주변에서의 사격 소음 예측이 가능하다. 또한, 이 데이터는 동일한 총에 사용되는 다른 종류의 총알 또는 다른 종류의 총기로부터의 소리 방출을 비교하는 데에도 사용될 수 있다. 이 문서는 민간 사격장에서 사용되는 총기에 적용될 수 있지만, 군용 총기에도 적용될 수 있다. 이 문서는 비선형 지역에서의 청력 손상 또는 음향 수준에 대한 평가에는 적용되지 않는다. 저음소거기(서프레서)와 소음 저감기(실렌서)는 이 문서에서 고려되지 않는다.
記事のタイトル:ISO 17201-1:2018 - 音響 - 射撃場からの騒音 - 第1部:測定によるマズルブラストの決定 記事の内容:この文書は、口径が20mm未満またはTNT換算で50g未満の爆発物を使用する銃のマズルブラストの音響エネルギーを決定する方法を規定しています。ピーク圧力が1kPa(ピークサウンド圧力レベル154dBに相当)未満の距離で適用されます。この手順で決定されたエネルギー源、音源の指向性、およびスペクトル構造は、音響伝播プログラムに入力データとして使用でき、射撃場周辺での銃声を予測することができます。また、同じ銃で使用される異なるタイプの銃弾や弾薬の音響放射を比較するためにもデータを使用できます。この文書は市民の射撃場で使用される銃に適用されますが、軍用銃にも適用できます。非線形領域における聴力の損傷や音量の評価には適用されませんし、消音器やサイレンサーは考慮されていません。










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...