Abstract

IEC 61760-4:2026 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to semiconductor devices, and devices for flow (wave) soldering.
NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749‑20 or J-STD-020F and J-STD-033, are described in the Introduction.
This edition includes the following significant technical changes with respect to the previous edition:
a) The content is updated to cover the classification conditions given in the new editions of J-STD-020F and IEC 60068-2-58.

Status
Published
Publication Date
27-May-2026
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
28-May-2026
Due Date
19-Jun-2026
Completion Date
19-Jun-2026

Buy Documents

Standard

IEC 61760-4:2026 - Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices

ISBN:978-2-8327-1256-6
Release Date:28-May-2026
English language (30 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

REDLINE IEC 61760-4:2026 RLV - Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices

ISBN:978-2-8327-1282-5
Release Date:28-May-2026
English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61760-4:2026 - Technologie de montage en surface - Partie 4: Classification, emballage, étiquetage et manipulation des dispositifs sensibles a l'humidité

ISBN:978-2-8327-1256-6
Release Date:28-May-2026
French language (33 pages)
sale 15% off
Preview
sale 15% off
Preview

IEC 61760-4:2026 is an International Standard from IEC on surface mounting technology. It specifies how moisture sensitive devices are classified by moisture sensitivity level for soldering heat, and how they are packaged, labelled, stored, handled and dried before reflow soldering. It is written for surface mount devices and certain through-hole devices that the supplier has documented for reflow soldering, not for semiconductor devices or devices for flow (wave) soldering.

What does IEC 61760-4:2026 specify?

IEC 61760-4:2026 defines a moisture sensitivity classification scheme and the related packaging, labelling and handling provisions for moisture sensitive devices. It extends classification and packaging methods to device types where existing standards are not required or not suitable, and introduces additional moisture sensitivity levels and an alternative dry-pack method.

The document is organized into:

  • Clause 4: general information on moisture sensitivity and the meaning of MSL
  • Clause 5: assessment and classification, including the non-moisture sensitive level N
  • Clause 6: test procedure for classification
  • Clause 7: packaging and labelling requirements
  • Clause 8: storage, humidity indication, unpacking and re-packing
  • Clause 9: drying methods and bakeout considerations
  • Annexes A to D for assemblies, mass/gain loss analysis, baking examples, and labels
AnnexWhat it covers
Annex AMoisture sensitivity of assemblies
Annex BMass/gain loss analysis
Annex CBaking of devices and an example baking process
Annex DMoisture sensitivity labels and graphical symbols

What are the key requirements of IEC 61760-4:2026?

Classification is based on moisture sensitivity level and reflow soldering heat

IEC 61760-4:2026 classifies devices by moisture sensitivity level (MSL) according to their response to moisture followed by soldering heat. Clause 5 says non-moisture sensitive devices can be identified by design and material analysis and designated level N, while Clause 6 defines the test route for devices that are moisture sensitive.

In practice, this tells a supplier or buyer whether a part can be handled as a standard dry component or whether it needs controlled packaging, limited floor life, and pre-bake steps before reflow.

The test sequence is drying, moisture soak, temperature load, recovery, then final inspection

Clause 6 requires a defined sequence: drying, moisture soak, temperature load, recovery, and final measurements. The specimen is baked before the soak, then subjected to soak conditions selected from Table 2, then to the classification temperature profile in Figure 1 and Tables 3 and 4, followed by recovery under standard atmospheric conditions from IEC 60068-1.

This matters because the classification is not based on humidity alone. It checks whether moisture absorbed before soldering can cause damage during reflow, which is the actual manufacturing risk.

Classification uses defined soak conditions and reflow cycles

Clause 6.4 requires three reflow cycles under the appropriate classification profile. The profile limits heating and cooling gradients and ties the classification temperature to the solder process and package type. For special devices, the standard allows the profiles from IEC 60068-2-58:2015 Table 7, or other agreed profiles in the relevant specification.

For users, this means the classification must match the way the device is actually assembled. For suppliers, it means the relevant specification needs to state the profile and any agreed deviations.

Pass or fail is decided by inspection and electrical checks

Clause 6.6 requires visual inspection, electrical measurements, and, if required, non-destructive inspection. Visual inspection focuses on cracks, delamination, swelling, warpage, bulging and dimensional changes. Clause 6.7 states that if one or more test samples fail at final measurements, the package does not pass that level.

This is important in practice because the standard is looking for package damage that can show up only after moisture and heat exposure. The inspection criteria protect assembly yield and field reliability.

Packaging uses moisture barrier bags, desiccant and humidity indication

Clause 7 defines the dry-pack approach. Devices are packed in a moisture barrier bag (MBB), with desiccant and humidity indication. The standard distinguishes MBB Type 1 and Type 2 by water vapour transmission rate (WVTR), and links desiccant quantity to bag size, WVTR and intended shelf life.

For the user, this means packaging is not just for shipping - it is part of the protection strategy that maintains shelf life and controls exposure before soldering.

Labels must show the key handling information

Annex D and Clause 7.3 require moisture sensitivity labelling. The moisture sensitivity caution label (MSCL) on the MBB carries the MSL, shelf life in the sealed bag, the peak body top surface temperature used for classification, floor life at 30 °C and 60 % RH, and the bag seal date. The moisture sensitivity identification label (MSID) identifies containers holding moisture sensitive devices.

This helps production, stores and receiving staff see how long the bag can remain open and whether the parts still need baking.

Storage, floor life and drying are controlled to preserve solderability

Clause 8 gives storage conditions, shelf life and floor life guidance. Clause 9 gives drying options and bakeout conditions, including re-bake after excessive exposure and baking before dry pack. The standard also limits high-temperature baking time to reduce oxidation and solderability loss.

In practice, this is the part that supports shop-floor decisions: whether parts can still be used as received, whether they need re-bake, and how long they may remain outside the bag before reflow.

What terms does IEC 61760-4:2026 define?

  • moisture sensitive device (MSD) - A device that can suffer electrical or mechanical degradation during soldering because absorbed moisture vaporizes.
  • moisture sensitivity level (MSL) - A rating that shows how susceptible a device is to moisture damage during reflow soldering.
  • moisture barrier bag (MBB) - A bag designed to limit water vapour transmission and protect moisture sensitive devices in dry pack.
  • manufacturer’s exposure time (MET) - The maximum time after baking before the component must be sealed, including allowed distributor opening time where applicable.
  • floor life - The allowable time a device may stay in normal room conditions after opening the MBB and before reflow.
  • shelf life - The time a product can remain in its original packaging under specified storage, transport and handling conditions while quality remains acceptable.
  • humidity indicator card (HIC) - A card with moisture-sensitive dots that change colour when the indicated relative humidity is exceeded.
  • water vapour transmission rate (WVTR) - The measure used to specify how much moisture can pass through the MBB material.

Who uses IEC 61760-4:2026?

IEC 61760-4:2026 is used by component manufacturers, distributors, electronics assemblers, and quality or reliability engineers who need a shared method for classifying and handling moisture sensitive parts. It is also relevant to buyers and supply-chain teams who set packaging and storage expectations, and to test laboratories that perform moisture sensitivity classification.

In practice, it is used for product qualification, incoming goods control, packaging design, dry-pack preparation, labelling, storage rules, and rework or baking decisions before reflow soldering.

What changed in IEC 61760-4:2026 from the previous edition?

IEC 61760-4:2026 is the second edition. It cancels and replaces the first edition published in 2015 and Amendment 1:2018.

The significant technical change stated for this edition is that the content has been updated to cover the classification conditions given in the new editions of J-STD-020F and IEC 60068-2-58.

Which standards are used with IEC 61760-4:2026?

  • IEC 60068-1:2013 - Gives the standard atmospheric conditions used for recovery and general environmental-testing guidance.
  • IEC 60068-2-58:2015 and IEC 60068-2-58 - Provide solderability and soldering-heat test methods and, for special devices, alternative temperature profiles.
  • IEC 61760-2 - Gives the storage conditions referenced for moisture sensitive devices.
  • IEC 61340-5-1 - Provides guidance for electrostatic discharge (ESD) protection during handling.
  • IEC 60417:2025 DB:2025 - Provides the standardized graphical symbol for moisture sensitive devices.
  • JEDEC JEP113 - Provides symbol and label examples used for moisture sensitive devices.
  • J-STD-020F - Supplies the moisture/reflow sensitivity classification conditions that this standard aligns with and extends.
  • J-STD-033 - Covers handling, packaging, shipping and use of moisture/reflow sensitive surface mount devices.
  • IEC 60749-20 - Is cited as background for plastic encapsulated semiconductors, which helps explain the scope of this part.

What does the IEC 61760-4:2026 document contain?

IEC 61760-4:2026 contains the classification tables, soak conditions, and temperature profiles used to assess moisture sensitivity. It also includes package-related data such as MBB material properties, HIC requirements, and example re-bake and baking conditions.

The document provides:

  • Figure 1 for the classification temperature profile
  • Figure 2 for examples of humidity indicator cards
  • Figure C.1 for an example baking process
  • Figures D.1 to D.3 for symbols and label examples
  • Tables 1 to 7 covering MSL levels, soak conditions, classification temperatures, MBB properties, and baking conditions
  • Formulae for calculating desiccant mass and related packaging design values

Annex B gives a practical mass/gain loss analysis method for evaluating absorption and desorption. Annex D gives the label content and symbol set used to identify moisture sensitive devices and their handling precautions.

Relations

Effective Date
20-Sep-2024
Effective Date
12-Apr-2024

Buy Documents

Standard

IEC 61760-4:2026 - Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices

ISBN:978-2-8327-1256-6
Release Date:28-May-2026
English language (30 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

REDLINE IEC 61760-4:2026 RLV - Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices

ISBN:978-2-8327-1282-5
Release Date:28-May-2026
English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61760-4:2026 - Technologie de montage en surface - Partie 4: Classification, emballage, étiquetage et manipulation des dispositifs sensibles a l'humidité

ISBN:978-2-8327-1256-6
Release Date:28-May-2026
French language (33 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 61760-4:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Surface mounting technology - Part 4: Classification, packaging, labelling and handling of moisture sensitive devices". This standard covers: IEC 61760-4:2026 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to semiconductor devices, and devices for flow (wave) soldering. NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749‑20 or J-STD-020F and J-STD-033, are described in the Introduction. This edition includes the following significant technical changes with respect to the previous edition: a) The content is updated to cover the classification conditions given in the new editions of J-STD-020F and IEC 60068-2-58.

IEC 61760-4:2026 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to semiconductor devices, and devices for flow (wave) soldering. NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749‑20 or J-STD-020F and J-STD-033, are described in the Introduction. This edition includes the following significant technical changes with respect to the previous edition: a) The content is updated to cover the classification conditions given in the new editions of J-STD-020F and IEC 60068-2-58.

IEC 61760-4:2026 is classified under the following ICS (International Classification for Standards) categories: 31.190 - Electronic component assemblies. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61760-4:2026 has the following relationships with other standards: It is inter standard links to IEC 61760-4:2015/AMD1:2018, IEC 61760-4:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61760-4:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 moisture sensitive device
  • 3.2 moisture sensitivity level
  • 3.3 moisture barrier bag
  • 3.4 manufacturer’s exposure time
  • 3.5 floor life
  • 3.6 shelf life
  • 3.7 active desiccant
  • 3.8 moisture indicating desiccant
  • 3.9 humidity indicator card
  • 3.10 water vapour transmission rate
  • 4 General information
  • 4.1 Moisture sensitive devices
  • 4.2 Moisture sensitivity level (MSL)
  • 4.3 Relation to other environmental test methods (humidity tests)
  • 5 Assessment of moisture sensitivity
  • 5.1 Identification of non-moisture sensitive devices
  • 5.2 Classification
  • 6 Test procedure
  • 6.1 General
  • 6.2 Drying
  • 6.3 Moisture soak
  • 6.4 Temperature load
  • 6.5 Recovery
  • 6.6 Final measurements
  • 6.7 Classification
  • 6.8 Information to be given in the relevant specification
  • 7 Requirements to packaging and labelling
  • 7.1 Packaging process
  • 7.2 Packaging material for dry pack
  • 7.3 Information to be given on labels
  • 8 Handling of moisture sensitive devices
  • 8.1 Storage
  • 8.2 ESD
  • 8.3 Humidity indication
  • 8.4 Unpacking and re-packing
  • 9 Drying
  • 9.1 Drying options
  • 9.2 Methods
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Bibliography

INTRODUCTION Due to the higher temperature profiles of reflow soldering processes using tin-silver-copper alloys or other lead-free solder alloys with higher melting temperatures than Sn-Pb eutectic solder, the sensitivity of components against soldering heat, when being exposed to moisture before soldering, becomes an increasingly important factor.

The currently existing standards describing the moisture sensitivity classification of devices are applicable for plastic encapsulated semiconductors and similar solid state packages (e.g. IEC 60749-20 [1]), but not for other types of components.

This part of IEC 61760 also extends the classification and packaging methods as described in J-STD-020F [2] and J-STD-033 [3]. It is intended to be used for such type of components, where J-STD-020F [2] and J-STD-033 [3] are not required or not appropriate. It is important to note that moisture sensitivity levels existing in both J-STD-020F [2] and this document are equivalent.

1 Scope

This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to - semiconductor devices, - devices for flow (wave) soldering.

NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60068-1:2013, Environmental testing - Part 1: General and guidance

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1 moisture sensitive device

MSD device where during soldering the evaporation of absorbed moisture is likely to deteriorate its electrical or mechanical performance compared to what is given in the relevant specification Note 1 to entry: This note applies to the French language only.

3.2 moisture sensitivity level

MSL rating indicating a device’s susceptibility to damage due to absorbed moisture when subjected to reflow soldering Note 1 to entry: This note applies to the French language only.

3.3 moisture barrier bag

MBB bag designed to restrict the transmission of water vapour and used to pack moisture sensitive devices (3.1) Note 1 to entry: This note applies to the French language only.

3.4 manufacturer’s exposure time

MET maximum time after baking that the component manufacturer requires to process components prior to sealing of the bag Note 1 to entry: The manufacturer’s exposure time also includes the maximum time allowed at the distributor in order to keep the bag open to split up its content into smaller shipments. Note 2 to entry: This note applies to the French language only.

3.5 floor life

allowable time for a device or semi-finished assembly to be exposed to normal room environment humidity and temperature after removal from a moisture barrier bag (3.3) or storage chamber and before a solder reflow process

3.6 shelf life

recommendation of time that products can be stored in the original packaging, during which the defined quality of the goods remains acceptable under specified conditions of transportation, storage and handling

3.7 active desiccant

absorbent material used to maintain a low relative humidity

3.8 moisture indicating desiccant

desiccant whose colour (hue) changes perceptibly, when a certain relative humidity is exceeded Note 1 to entry: Typically a colour change due to a moisture indicating desiccant is from blue to pink, when the change from dry state to wet state is detected.

3.9 humidity indicator card

HIC card on which a moisture sensitive chemical is printed such that it changes colour from dry to wet when the indicated relative humidity is exceeded Note 1 to entry: This note applies to the French language only.

3.10 water vapour transmission rate

WVTR measure of the permeability of a plastic film material to moisture, used to specify a moisture barrier bag (3.3) for dry packing Note 1 to entry: This note applies to the French language only.

4 General information

4.1 Moisture sensitive devices

Certain materials, plastic polymers and fillers are hygroscopic and can absorb moisture dependent on time and the storage environment. Absorbed moisture will vaporize during rapid heating in the solder reflow process, generating - pressure in the material, - deformation, - swelling, - delamination, - cracking, - degradation of inner connection.

The penetration of moisture into the absorbing material is generally caused through exposure to the ambient air. Moisture absorption or moisture penetrating into cavities can lead to moisture concentrations in the device which are high enough to cause cracking or delamination to the device during the soldering process (e.g. “popcorn phenomenon”), which can adversely affect reliability.

NOTE “Popcorn phenomenon” defines internal stress causes the package to bulge and then crack with an audible “pop”.

Moisture can also influence the bonding strength of adhesives, sealings, encapsulants, plastics with galvanic coating, etc.

Moisture exposure also can induce the transport of ionic contaminations into the device, thereby increasing the potential for circuit failure due to corrosion. Hence it is necessary to dry moisture sensitive devices , to seal them in a moisture barrier bag and to remove them immediately prior to soldering onto the circuit board. The permissible time, from the opening of the moisture barrier bag until the final soldering process, that a device can remain unprotected in an environment with a level of humidity approximating to real-world conditions (e.g. 30 °C/60 % RH) is a measure of the sensitivity of the device to ambient humidity. This amount of time is called floor life.

4.2 Moisture sensitivity level (MSL)

The moisture sensitivity level (MSL) is determined at the classification temperature, which is set above practical soldering temperatures. The actual soldering temperature measured at the top surface of the component therefore shall be less than the classification temperature. Packaging, storage, floor life and pre-treatment of moisture sensitive devices before being subjected to reflow soldering processes are identified by the MSL (see Clause 5 and Table 1). The method for classification of devices into MSL is described in Clause 6.

4.3 Relation to other environmental test methods (humidity tests)

In humidity tests, for example as in IEC 60068-2-78 [4], devices are tested either in unmounted or in mounted condition (e.g. soldered to a test board). These tests detect the influence of adsorbed or absorbed moisture to the performance of the device (e.g. electrical characteristics, corrosion effects), but cannot detect the influence of absorbed moisture to the sensitivity against heat stresses of the soldering processes.

The target of the test method described in this document is to test the resistance of devices against the soldering heat in combination with the humidity load as preconditioning process.

Other effects of humidity, like deterioration of electrical characteristics or isolation properties, are not covered by this document and shall be tested separately.

5 Assessment of moisture sensitivity

5.1 Identification of non-moisture sensitive devices

Non-moisture sensitive devices shall be identified by analysis of design and materials of devices depending on whether they can absorb humidity, or humidity can penetrate into cavities. If the materials apparently do not absorb humidity, the devices can be declared by the manufacturer as non-moisture sensitive.

Such non-moisture sensitive devices shall be designated as level “N”. There are no requirements for non-moisture sensitive devices .

5.2 Classification

The procedure to classify moisture sensitive devices into MSL is described in Clause 6. The devices are classified at the appropriate classification temperature selected from Table 3 and Table 4. See Annex A for the classification of semi-finished assemblies. The recommended procedure is to start testing at the lowest moisture sensitivity level, which the evaluation package is reasonably expected to pass (based on knowledge of other similar evaluation packages).

If suppliers and users agree, components can be classified at temperatures other than those in Table 4.

If the conditions in Table 1 or Table 2 are not suitable for a specific product, other conditions can be applied according to the agreement between users and suppliers. Table 1 – Moisture sensitivity levels LEVEL floor life Floor life shelf life Protective packaging Desicca Humidity time condition nt indicator (reference condition) 1 a ≤30 °C/85 % RH 12 months No requirement

or as 2 a ≤30 °C/60 % RH b No Optional specified 1 year MBB type 1 , <60 % RH in

by the MBB no pre-drying supplier C2a 4 weeks ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 2a b MBB type 2 , <10 % RH in MBB pre-drying C3 168 h ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 3 b MBB type 2 , <10 % RH in MBB pre-drying 4 72 h ≤30 °C/60 % RH b Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying 5 48 h ≤30 °C/60 % RH c Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying

LEVEL floor life Floor life shelf life Protective packaging Desicca Humidity time condition nt indicator (reference condition) The floor life can be longer if the environmental conditions are less severe than the reference condition, or shorter, if more severe.

Extended shelf life can be agreed upon, but requires recalculation of the amount of desiccant. a The sum of keeping time at floor and storage time should not exceed the maximum storage period as specified by the supplier.

b The required shelf life and humidity in packed condition shall be assured by the amount of the desiccant, calculated by the use of water vapour transmission rate (WVTR) of the applied MBB. For the description of MBB type, see Table 5.

Humidity indicator can be HIC or moisture indicating desiccant.

6 Test procedure

6.1 General

6.1.1 Structurally similar components

Classification may be performed for a group of structurally similar components. Information about structural similarity shall be given in the relevant specification.

6.1.2 Verification and validation tests

The relevant specification shall describe the minimum number of specimens to be tested. The minimum number should be at least 11 pieces.

NOTE A sample of 11 pieces tested with an acceptance number zero represents a Lot Tolerance Percent Defective (LTPD) of 20 % with a confidence level (C.L.) of 90 %. See ISO 2859-1 [5] for further information.

6.1.3 Selection of applicable soak conditions and temperature profile

The soak conditions related to the MSL shall be selected from Table 2, the applicable temperature profile for classification (Figure 1) from Table 3 and Table 4.

6.2 Drying

The specimen shall be baked at 125 °C ± 5 °C for at least 24 h, unless otherwise specified in the relevant specification.

However, alternative baking conditions may be applied, when confirmed by the mass gain or loss analysis as described in Annex B.

6.3 Moisture soak

Table 2 – Moisture soak conditions LEVEL Soak time (h) a Alternative Soak condition 1 (168 +5/−0) (85 ± 2) °C, (85 ± 5) % RH (336 +5/−0) h; (85 ± 2) °C, (60 ± 5) % RH 2 (168 +5/−0) (85 ± 2) °C, (60 ± 5) % RH – C2a (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, – followed by followed by (30 ± 2) °C, (672 +5/−0) (60 ± 5) % RH 2a (696 + 5/−0) (30 ± 2) °C, (60 ± 5) % RH C3 (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, followed by followed by (30 ± 2) °C, (168 +5/−0) (60 ± 5) % RH

LEVEL Soak time (h) a Alternative Soak condition 3 (192 +5/−0) (30 ± 2) °C, (60 ± 5) % RH 4 (96 +2/−0) (30 ± 2) °C, (60 ± 5) % RH 5 (72 +2/−0) In levels C2a and C3, the first stage of soak condition corresponds to shelf life (≤30 °C, ≤30 % RH, one year) in the MBB type 1. The second stage of soak condition corresponds to floor life (as in IEC 60749-20 [1]). a Soak conditions according to J-STD-020F [2]. Alternatively accelerated equivalent soak conditions from Table 4 in J-STD-020F [2] may be applied in case the activation energy is confirmed by the manufacturer.

6.4 Temperature load

6.4.1 Classification temperature profile

Key Minimum preheating temperature T

Maximum preheating temperature T

Liquidus temperature T

Classification temperature T

Preheating duration t

Time at liquidus t

t Time within (T – 5 °C) 3 c t Time to T 4 c a Temperature gradient of the increasing slope b Preheat area c Temperature gradient of the decreasing slope The temperature gradient of the increasing slope shall not exceed 3 K/s and the temperature gradient of the decreasing slope shall not exceed 6 K/s.

Figure 1 – Classification temperature profile

Table 3 – Parameters of the classification temperature profile Solder Sn-Pb (or equivalent) SnAgCu (or equivalent) Sn-Bi (or equivalent) process 100 °C 150 °C 100 °C T

150 °C 200 °C 120 °C T

(60 to 120) s (60 to 120) s (30 to 90) s t

183 °C 217 °C 139 °C T

(60 to 150) s (60 to 150) s (60 to 150) s t

20 s 30 s 20 s t

See Table 4 T

≤6 min ≤8 min ≤4 min t

Table 4 – Classification temperatures T

Solder process Package Classification temperature T for package volume

thickness 3 3 3 <350 mm 350 mm to >2 000 mm

2 000 mm mm °C °C °C

SnPb (or <2,5 235 220 220 equivalent) ≥2,5 220 220 220 SnAgCu (or <1,6 260 260 260 equivalent) 1,6 to 2,5 260 250 245 >2,5 250 245 245 >2,5 plus high not applicable b b 230 230 a thermal capacity Sn-Bi (or All package thickness and volume: 190 equivalent) [LTS] a This condition may be applied for devices with high thermal mass, where peak package temperature does not reach 245 °C when soldered with a profile typical to soldering processes using SnAgCu alloy solder, or for very temperature sensitive devices. The peak package temperature is measured at the device surface or any other point specified in the relevant specification.

b T measured at the device terminal or solder joint shall achieve the minimum temperature and time necessary

for a specific solder alloy to form a solder joint.

6.4.2 Classification temperature profile for special devices

When the classification temperature profiles of Table 3 and Table 4 are not applicable to a device (e.g. components with high thermal mass or thermal sensitivity) the temperature profiles in IEC 60068-2-58:2015 [6], Table 7, can be used. Other profiles may be specified in the relevant specification according to the agreement between user and supplier. For information see also J-STD 075A [7].

6.4.3 Reflow

The sample shall be subjected to 3 cycles of the appropriate reflow conditions as defined in Figure 1, Table 3 and Table 4, starting in a time interval of 15 min to 4 h after removal from the temperature/humidity chamber. The recovery period between two successive cycles shall be the time it takes until the temperature of the specimen drops below 50 °C.

If the timing between removal from climatic test chamber and initial reflow cannot be met, the parts shall be rebaked and resoaked according to 6.2 and 6.3.

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 moisture sensitive device
  • 3.2 moisture sensitivity level
  • 3.3 moisture barrier bag
  • 3.4 manufacturer’s exposure time
  • 3.5 floor life
  • 3.6 shelf life
  • 3.7 active desiccant
  • 3.8 unit of desiccant
  • 3.8 moisture indicating desiccant
  • 3.9 humidity indicator card
  • 3.10 water vapour transmission rate
  • 4 General information
  • 4.1 Moisture sensitive devices
  • 4.2 Moisture sensitivity level (MSL)
  • 4.3 Relation to other environmental test methods (humidity tests)
  • 5 Assessment of moisture sensitivity
  • 5.1 Identification of non-moisture sensitive devices
  • 5.2 Classification
  • 6 Test procedure
  • 6.1 General
  • 6.2 Drying
  • 6.3 Moisture soak
  • 6.4 Temperature load
  • 6.5 Recovery
  • 6.6 Final measurements
  • 6.7 Classification
  • 6.8 Information to be given in the relevant specification
  • 7 Requirements to packaging and labelling
  • 7.1 Packaging process
  • 7.2 Packaging material for dry pack
  • 7.3 Information to be given on labels
  • 8 Handling of moisture sensitive devices
  • 8.1 Storage
  • 8.2 ESD
  • 8.3 Humidity indication
  • 8.4 Unpacking and re-packing
  • 9 Drying
  • 9.1 Drying options
  • 9.2 Methods
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Bibliography
  • FOREWORD
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 moisture sensitive device
  • 3.2 moisture sensitivity level
  • 3.3 moisture barrier bag
  • 3.4 manufacturer’s exposure time
  • 3.5 floor life
  • 3.6 shelf life
  • 3.7 active desiccant
  • 3.8 moisture indicating desiccant
  • 3.9 humidity indicator card
  • 3.10 water vapour transmission rate
  • 4 General information
  • 4.1 Moisture sensitive devices
  • 4.2 Moisture sensitivity level (MSL)
  • 4.3 Relation to other environmental test methods (humidity tests)
  • 5 Assessment of moisture sensitivity
  • 5.1 Identification of non-moisture sensitive devices
  • 5.2 Classification
  • 6 Test procedure
  • 6.1 General
  • 6.2 Drying
  • 6.3 Moisture soak
  • 6.4 Temperature load
  • 6.5 Recovery
  • 6.6 Final measurements
  • 6.7 Classification
  • 6.8 Information to be given in the relevant specification
  • 7 Requirements to packaging and labelling
  • 7.1 Packaging process
  • 7.2 Packaging material for dry pack

INTRODUCTION Due to the higher temperature profiles of reflow soldering processes using tin-silver-copper alloys or other lead-free solder alloys with higher melting temperatures than Sn-Pb eutectic solder, the sensitivity of components against soldering heat, when being exposed to moisture before soldering, becomes an increasingly important factor.

The currently existing standards describing the moisture sensitivity classification of devices are applicable for plastic encapsulated semiconductors and similar solid state packages (e.g. IEC 60749-20 [1]), but not for other types of components.

This part of IEC 61760 also extends the classification and packaging methods as described in J-STD-020F [2] and J-STD-033 [3]. It is intended to be used for such type of components, where J-STD-020F [2] and J-STD-033 [3] are not required or not appropriate. It is important to note that moisture sensitivity levels existing in both J-STD-020F [2] and this document are equivalent.

1 Scope

This part of IEC 61760 specifies the classification of moisture sensitive device into moisture sensitivity level related to soldering heat, and provisions for packaging, labelling and handling. It extends the classification and packaging methods to such components, where currently existing standards are not required or not appropriate. For such cases, this document introduces additional moisture sensitivity levels and an alternative method for packaging. This document applies to devices intended for reflow soldering, like surface mount devices, including specific through-hole devices (where the device supplier has specifically documented support for reflow soldering), but not to - semiconductor devices, - devices for flow (wave) soldering.

NOTE Background of this document and its relation to currently existing standards, e.g. IEC 60749-20 [1] or J-STD-020F [2] and J-STD-033 [3], are described in the Introduction.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60068-1:2013, Environmental testing - Part 1: General and guidance IEC 60749-20, Semiconductor devices – Mechanical and climatic test methods – Part 20:

Resistance of plastic encapsulated SMDs to the combined effect of moisture and soldering heat IEC 61340-5-1, Electrostatics – Part 5-1: Protection of electronic devices from electrostatic phenomena – General requirements IEC 61760-2, Surface mounting technology – Part 2: Transportation and storage conditions of surface mounting devices (SMD) – Application guide IPC/JEDEC J-STD-020E, January 2015, Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1 moisture sensitive device

MSD device where during soldering the evaporation of absorbed moisture is likely to deteriorate its electrical or mechanical performance compared to what is given in the relevant specification Note 1 to entry: This note applies to the French language only.

3.2 moisture sensitivity level

MSL rating indicating a device’s susceptibility to damage due to absorbed moisture when subjected to reflow soldering Note 1 to entry: This note applies to the French language only.

3.3 moisture barrier bag

MBB bag designed to restrict the transmission of water vapour and used to pack moisture sensitive devices (3.1) Note 1 to entry: This note applies to the French language only.

3.4 manufacturer’s exposure time

MET maximum time after baking that the component manufacturer requires to process components prior to sealing of the bag Note 1 to entry: The manufacturer’s exposure time also includes the maximum time allowed at the distributor in order to keep the bag open to split up its content into smaller shipments. Note 2 to entry: This note applies to the French language only.

3.5 floor life

allowable time for a device or semi-finished assembly to be exposed to normal room environment humidity and temperature after removal from a moisture barrier bag (3.3) or storage chamber and before a solder reflow process

3.6 shelf life

recommendation of time that products can be stored in the original packaging, during which the defined quality of the goods remains acceptable under specified conditions of transportation, storage and handling

3.7 active desiccant

absorbent material used to maintain a low relative humidity

3.8 unit of desiccant

amount of active desiccant that will absorb a minimum of 2,85 g of water vapour at 25 °C and a relative humidity of 20 % within 24 h

3.8 moisture indicating desiccant

desiccant whose colour (hue) changes perceptibly, when a certain relative humidity is exceeded Note 1 to entry: Typically a colour change due to a moisture indicating desiccant is from blue to pink, when the change from dry state to wet state is detected.

3.9 humidity indicator card

HIC card on which a moisture sensitive chemical is printed such that it changes colour from dry to wet when the indicated relative humidity is exceeded

Note 1 to entry: This note applies to the French language only.

3.10 water vapour transmission rate

WVTR measure of the permeability of a plastic film material to moisture, used to specify a moisture barrier bag (3.3) for dry packing Note 1 to entry: This note applies to the French language only.

4 General information

4.1 Moisture sensitive devices

Certain materials, plastic polymers and fillers are hygroscopic and can absorb moisture dependent on time and the storage environment. Absorbed moisture will vaporize during rapid heating in the solder reflow process, generating - pressure in the material, - deformation, - swelling, - delamination, - cracking, - degradation of inner connection.

The penetration of moisture into the absorbing material is generally caused through exposure to the ambient air. Moisture absorption or moisture penetrating into cavities can lead to moisture concentrations in the device which are high enough to cause cracking and/or delamination to the device during the soldering process (e.g. “popcorn phenomenon”), which may can adversely affect reliability.

NOTE “Popcorn phenomenon” defines internal stress causes the package to bulge and then crack with an audible “pop”.

Moisture can also influence the bonding strength of adhesives, sealings, encapsulants, plastics with galvanic coating, etc.

Moisture exposure also can induce the transport of ionic contaminations into the device, thereby increasing the potential for circuit failure due to corrosion. Hence it is necessary to dry moisture sensitive devices , to seal them in a moisture barrier bag and only to remove them immediately prior to soldering onto the PCB circuit board. The permissible time, from the opening of the moisture barrier bag until the final soldering process, that a device can remain unprotected in an environment with a level of humidity approximating to real-world conditions (e.g. 30 °C/60 % RH) is a measure of the sensitivity of the device to ambient humidity. This amount of time is called floor life.

4.2 Moisture sensitivity level (MSL)

The moisture sensitivity level (MSL) is determined at the classification temperature, which is set above practical soldering temperatures. The actual soldering temperature measured at the top surface of the component therefore shall be less than the classification temperature. Packaging, storage, floor life and pre-treatment of moisture sensitive devices before being subjected to reflow soldering processes are identified by the MSL (see Clause 5 and Table 1). The method for classification of devices into MSL is described in Clause 6.

4.3 Relation to other environmental test methods (humidity tests)

In humidity tests, for example as in IEC 60068-2-78 [4], devices are testedeither in unmounted or in mounted condition (e.g. soldered to a test board). These tests detect the influence of adsorbed or absorbed moisture to the performance of the device (e.g. electrical characteristics, corrosion effects), but cannot detect the influence of absorbed moisture to the sensitivity against heat stresses of the soldering processes.

The target of the test method described in this document is to test the resistance of devices against the soldering heat in combination with the humidity load as preconditioning process. Other effects of humidity, like deterioration of electrical characteristics or isolation properties, are not covered by this document and need to shall be tested separately.

5 Assessment of moisture sensitivity

5.1 Identification of non-moisture sensitive devices

Non-moisture sensitive devices shall be identified by analysis of design and materials of devices depending on whether they can absorb humidity, or humidity can penetrate into cavities. If the materials apparently do not absorb humidity, the devices may can be declared by the manufacturer as non-moisture sensitive.

Such non-moisture sensitive devices shall be designated as level “N”. There are no requirements for non-moisture sensitive devices .

5.2 Classification

The procedure to classify moisture sensitive devices into MSL is described in Clause 6. The devices are classified at the appropriate classification temperature selected from Table 3 and Table 4. See Annex A for the classification of semi-finished assemblies. The recommended procedure is to start testing at the lowest moisture sensitivity level, which the evaluation package is reasonably expected to pass (based on knowledge of other similar evaluation packages).

If suppliers and users agree, components can be classified at temperatures other than those in Table 4.

If the conditions in Table 1 or Table 2 are not suitable for a specific product, other conditions can be applied according to the agreement between users and suppliers.

Table 1 – Moisture sensitivity levels LEVEL floor life Floor life shelf life Protective packaging Desicca Humidity time condition nt indicator (reference condition) 12 months 1 a ≤30 °C/85 % RH No requirement

or as 2 a ≤30 °C/60 % RH b No Optional specified 1 year MBB type 1 , <60 % RH in

by the MBB no pre-drying supplier C2a 4 weeks ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 2a b MBB type 2 , <10 % RH in MBB pre-drying C3 168 h ≤30 °C/60 % RH b Yes c MBB type 1 , <30 % RH in Yes MBB no pre-drying 3 b MBB type 2 , <10 % RH in MBB pre-drying 4 72 h ≤30 °C/60 % RH b Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying 5 48 h ≤30 °C/60 % RH bc Yes c MBB type 2 , <10 % RH Yes in MBB pre-drying The floor life can be longer if the environmental conditions are less severe than the reference condition, or shorter, if more severe.

Extended shelf life can be agreed upon, but needs requires recalculation of the amount of desiccant. a The sum of keeping time at floor and storage time should not exceed the maximum storage period as specified by the supplier.

b The required shelf life and humidity in packed condition shall be assured by the amount of the desiccant, calculated by the use of water vapour transmission rate (WVTR) of the applied MBB. For the description of MBB type, see Table 5.

Humidity indicator can be HIC or moisture indicating desiccant.

6 Test procedure

6.1 General

6.1.1 Structurally similar components

Classification may be performed for a group of structurally similar components. Information about structural similarity shall be given in the relevant specification.

6.1.2 Verification and validation tests

The relevant specification shall describe the minimum number of specimens to be tested. The minimum number should be at least 11 pieces.

NOTE A sample of 11 pieces tested with an acceptance number zero represents a Lot Tolerance Percent Defective (LTPD) of 20 % with a confidence level (C.L.) of 90 %. See ISO 2859-1 [5] for further information.

6.1.3 Selection of applicable soak conditions and temperature profile

The soak conditions related to the MSL shall be selected from Table 2, the applicable temperature profile for classification (Figure 1) from Table 3 and Table 4.

6.2 Drying

The specimen shall be baked at 125 °C ± 5 °C for at least 24 h, unless otherwise specified in the relevant specification.

However, alternative baking conditions can may be applied, when confirmed by the mass gain or loss analysis as described in Annex B.

6.3 Moisture soak

Table 2 – Moisture soak conditions LEVEL Soak time (h) a Alternative Soak condition 1 (168 +5/−0) (85 ± 2) °C, (85 ± 5) % RH (336 +5/−0) h; (85 ± 2) °C, (60 ± 5) % RH 2 (168 +5/−0) (85 ± 2) °C, (60 ± 5) % RH – C2a (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, – followed by followed by (30 ± 2) °C, (672 +5/−0) (60 ± 5) % RH 2a (696 + 5/−0) (30 ± 2) °C, (60 ± 5) % RH C3 (168 +5/−0) (85 ± 2) °C, (30 ± 5) % RH, followed by followed by (30 ± 2) °C, (168 +5/−0) (60 ± 5) % RH 3 (192 +5/−0) (30 ± 2) °C, (60 ± 5) % RH 4 (96 +2/−0) (30 ± 2) °C, (60 ± 5) % RH 5 (72 +2/−0) In levels C2a and C3, the first stage of soak condition corresponds to shelf life (≤30 °C, ≤30 % RH, one year) in the MBB type 1. The second stage of soak condition corresponds to floor life (as in IEC 60749-20 [1]). a Soak conditions according to IPC/JEDEC J-STD-020E J-STD-020F [2]. Alternatively accelerated equivalent soak conditions from Table 5-1 in J-STD-020E Table 4 in J-STD-020F [2] may be applied in case the activation energy is confirmed by the manufacturer.

6.4 Temperature load

6.4.1 Classification temperature profile

Key T Minimum preheating temperature

Maximum preheating temperature T

Liquidus temperature T

Classification temperature T

Preheating duration t

Time at liquidus t

t Time within (T – 5 °C) 3 c t Time to T 4 c a Temperature gradient of the increasing slope b Preheat area c Temperature gradient of the decreasing slope The temperature gradient of the increasing slope shall not exceed 3 K/s and the temperature gradient of the decreasing slope shall not exceed 6 K/s.

Figure 1 – Classification temperature profile

Table 3 – Parameters of the classification temperature profile Solder Sn-Pb (or equivalent) SnAgCu (or equivalent) Sn-Bi (or equivalent) process 100 °C 150 °C 100 °C T

150 °C 200 °C 120 °C T

(60 to 120) s (60 to 120) s (30 to 90) s t

183 °C 217 °C 139 °C T

(60 to 150) s (60 to 150) s (60 to 150) s t

20 s 30 s 20 s t

See Table 4 T

≤6 min ≤8 min ≤4 min t

Table 4 – Classification temperatures T

Solder process Package Classification temperature T for package volume

thickness 3 3 3 <350 mm 350 mm to >2 000 mm

2 000 mm mm °C °C °C

SnPb (or <2,5 235 220 220 equivalent) ≥2,5 220 220 220 SnAgCu (or <1,6 260 260 260 equivalent) 1,6 to 2,5 260 250 245 >2,5 250 245 245 >2,5 plus high not applicable b b 230 230 a thermal capacity Sn-Bi (or All package thickness and volume: 190 equivalent) [LTS] a This condition may be applied for devices with high thermal mass, where peak package temperature does not reach 245 °C when soldered with a profile typical to soldering processes using SnAgCu alloy solder, or for very temperature sensitive devices. The peak package temperature is measured at the device surface or any other point specified in the relevant specification.

b T measured at the device terminal or solder joint shall achieve the minimum temperature and time necessary

for a specific solder alloy to form a solder joint.

6.4.2 Classification temperature profile for special devices

When the classification temperature profiles of Table 3 and Table 4 are not applicable to a device (e.g. components with high thermal mass and/or thermal sensitivity) the temperature profiles in IEC 60068-2-58:2015 [6], Table 7, can be used. Other profiles may be specified in the relevant specification according to the agreement between user and supplier. For information see J-STD-075:2008 also J-STD 075A [7].

6.4.3 Reflow

The sample shall be subjected to 3 cycles of the appropriate reflow conditions as defined in Figure 1, Table 3 and Table 4, starting in a time interval between of 15 min to 4 h after removal from the temperature/humidity chamber. The recovery period between two successive cycles shall be the time it takes until the temperature of the specimen drops below 50 °C.

If the timing between removal from the temperature/humidity climatic test chamber and initial reflow cannot be met, the parts shall be rebaked and resoaked according to 6.2 and 6.3. All temperatures refer to the centre of the package, measured on the package body surface that is facing up during assembly reflow (for example live-bug orientation). For users, Tc shall not exceed the classification temperature in Table 4. For suppliers Tc shall be equal to or exceed the classification temperature in Table 4. NOTE 1 The temperature profile defined in Figure 1, Table 3 and Table 4 is the same as comparable to the test conditions and severities specified in IEC 60068-2-58 [8]. Thus, the temperature load used for testing resistance to soldering heat per each individual reflow treatment and for moisture sensitivity is equivalent. NOTE 2 The temperature profile defined in Figure 1, Table 3 and Table 4conforms with Figure 5-1 and Table 5-2 of J-STD-020E J-STD-020F [2], which allow wider tolerances of, for example, peak temperature compared to the prescription given in this document.

6.5 Recovery

The specimen shall be stored under the standard atmospheric conditions for measurements and test as given in IEC 60068-1:2013, (15 to 35) °C, (25 to 75) % RH for the time given in the relevant specification.

6.6 Final measurements

6.6.1 Requirements

A component is considered to pass that level of moisture sensitivity if it passes the requirements of 6.6.2 and 6.6.3, and if required, the non-destructive inspection of 6.6.4.

6.6.2 Visual inspection

Visual inspection shall be performed after the test. Special attention shall be paid to external cracks and swelling which will be looked for under a magnification of 40×. A device shall be considered as failure if it exhibits any of the following:

a) external crack visible using 40× optical microscope; b) internal crack or delamination that intersects internal connections; c) internal crack or delamination extending from any terminal to any other internal element relevant for the function of the device; d) internal crack or delamination extending more than 2/3 the distance from any internal element relevant for the function of the device to the outside of the package; e) changes in package body flatness caused by warpage, swelling or bulging invisible to the naked eye; f) dimensions out of specification.

Hot temperature warpage may be specified for multi-pin devices. If parts meet in hot condition coplanarity and stand-off dimensions as specified at room temperature, they shall be considered passing.

The relevant specification may prescribe additional inspection criteria. If internal cracks are detected by non-destructive inspection in 6.6.4, they are considered a failure or verified good using polished cross sections through the identified site. For packages known to be sensitive to vertical cracks, it is recommended that polished cross sections be used to confirm the non-existence of near vertical cracks within the mould compound or encapsulant.

...

Contents

  • 1 Domaine d’application
  • 2 Références normatives
  • 3 Termes et définitions
  • 3.1 dispositif sensible à l'humidité
  • 3.2 niveau de sensibilité à l'humidité
  • 3.3 sac de protection contre l'humidité
  • 3.4 temps d'exposition du fabricant
  • 3.5 durée de vie
  • 3.6 durée de conservation
  • 3.7 déshydratant actif
  • 3.8 déshydratant indicateur d'humidité
  • 3.9 carte indicateur d'humidité
  • 3.10 vitesse de transmission de la vapeur d'eau
  • 4 Informations générales
  • 4.1 Dispositifs sensibles à l'humidité
  • 4.2 Niveau de sensibilité à l'humidité (MSL)
  • 4.3 Relation avec d'autres méthodes d'essais d'environnement (essais d'humidité)
  • 5 Évaluation de la sensibilité à l'humidité
  • 5.1 Identification des dispositifs non sensibles à l'humidité
  • 5.2 Classification
  • 6 Mode opératoire d'essai
  • 6.1 Généralités
  • 6.2 Séchage
  • 6.3 Trempage dans l'humidité
  • 6.4 Charge de température
  • 6.5 Récupération
  • 6.6 Mesures finales
  • 6.7 Classification
  • 6.8 Informations à fournir dans la spécification applicable
  • 7 Exigences relatives à l'emballage et à l'étiquetage
  • 7.1 Processus d'emballage
  • 7.2 Matériau d'emballage pour emballage sec
  • 7.3 Informations devant figurer sur les étiquettes
  • 8 Manipulation des dispositifs sensibles à l'humidité
  • 8.1 Stockage
  • 8.2 ESD
  • 8.3 Indication d'humidité
  • 8.4 Déballage et remballage
  • 9 Séchage
  • 9.1 Options de séchage
  • 9.2 Méthodes
  • Bibliographie

INTRODUCTION En raison des profils de température plus élevés des procédés de brasage par refusion utilisant des alliages étain-argent-cuivre ou d'autres alliages de brasure sans plomb avec des températures de fusion plus élevées que la brasure eutectique Sn-Pb, la sensibilité des composants à la chaleur de brasage, lorsqu'ils sont exposés à l'humidité avant le brasage, devient un facteur de plus en plus important.

Les normes actuelles décrivant la classification de sensibilité à l'humidité des dispositifs sont applicables aux semi-conducteurs encapsulés en plastique et aux boîtiers semi-conducteurs similaires (par exemple, IEC 60749‑20 [1]), mais pas aux autres types de composants. La présente partie de l'IEC 61760 élargit également la classification et les méthodes d'emballage décrites dans la J-STD-020F [2] et la J-STD-033 [3]. Il est destiné à être utilisé pour ce type de composants, lorsque J-STD-020F [2] et J-STD-033 [3] ne sont pas exigés ou ne sont pas appropriés.

Il est important de noter que les niveaux de sensibilité à l'humidité (3.2) existants dans la J-STD-020F [2] et dans le présent document sont équivalents.

1 Domaine d’application

La présente partie de l'IEC 61760 spécifie la classification du dispositif sensible à l'humidité (3.1) en niveau de sensibilité à l'humidité (3.2) relatif à la chaleur de brasage, et les dispositions relatives à l'emballage, à l'étiquetage et à la manipulation.

Elle étend la classification et les méthodes d'emballage à ces composants, lorsque les normes existantes ne sont pas requises ou ne sont pas appropriées. Dans de tels cas, le présent document introduit des niveaux supplémentaires de sensibilité à l'humidité et une méthode alternative d'emballage.

Le présent document s'applique aux dispositifs destinés au brasage par refusion, tels que les dispositifs pour montage en surface, y compris les dispositifs spécifiques à trous traversants (lorsque le fournisseur du dispositif dispose d'un support spécifiquement documenté pour le brasage par refusion), mais pas aux dispositifs suivants - dispositifs à semiconducteurs, - dispositifs de brasage par flux (à la vague).

NOTE Le contexte du présent document et sa relation avec les normes existantes, par exemple l'IEC 60749‑20 [1] ou la J-STD-020F [2] et la J-STD-033 [3], sont décrits dans l'Introduction.

2 Références normatives

Les documents suivants sont cités dans le texte de sorte qu'ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).

IEC 60068-1, Essais d'environnement - Partie 1: Généralités et lignes directrices

3 Termes et définitions

Pour les besoins du présent document, les termes et définitions suivants s'appliquent. L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:

  • IEC Electropedia: disponible à l'adresse https://www.electropedia.org/
  • ISO Online browsing platform: disponible à l'adresse https://www.iso.org/obp

3.1 dispositif sensible à l'humidité

MSD dispositif dans lequel, pendant le brasage, l'évaporation de l'humidité absorbée est susceptible de détériorer ses performances électriques ou mécaniques par rapport à ce qui est indiqué dans la spécification applicable Note 1 à l'article: Cette note s'applique uniquement à la langue française.

3.2 niveau de sensibilité à l'humidité

MSL valeur assignée indiquant la sensibilité d'un dispositif aux dommages dus à l'humidité absorbée lorsqu'il est soumis à un brasage par refusion Note 1 à l'article: Cette note s'applique uniquement à la langue française.

3.3 sac de protection contre l'humidité

MBB sac conçu pour limiter la transmission de la vapeur d'eau et utilisé pour emballer les dispositifs sensibles à l'humidité (3.1) Note 1 à l'article: Cette note s'applique uniquement à la langue française.

3.4 temps d'exposition du fabricant

MET durée maximale après cuisson requise par le fabricant de composants pour traiter les composants avant le scellement du sac Note 1 à l'article: La durée d'exposition du fabricant inclut également la durée maximale autorisée au niveau du distributeur afin de maintenir le sac ouvert pour diviser son contenu en plus petites expéditions. Note 2 à l'article: Cette note s'applique uniquement à la langue française.

3.5 durée de vie

temps admissible pour qu'un dispositif ou un assemblage semi-fini soit exposé à l'humidité et à la température normales de l'environnement ambiant après avoir été retiré d'un sac barrière contre l'humidité (3.3) ou d'une chambre de stockage et avant un processus de refusion de la brasure

3.6 durée de conservation

recommandation de durée pendant laquelle les produits peuvent être stockés dans leur emballage d'origine, pendant laquelle la qualité définie des marchandises reste acceptable dans des conditions spécifiées de transport, de stockage et de manutention

3.7 déshydratant actif

matériau absorbant utilisé pour maintenir une faible humidité relative

3.8 déshydratant indicateur d'humidité

déshydratant dont la couleur (teinte) change de manière perceptible, lorsqu'une certaine humidité relative est dépassée Note 1 à l'article: Généralement, un changement de couleur dû à un déshydratant indicateur d'humidité est de bleu à rose, lorsque le changement de l'état sec à l'état humide est détecté.

3.9 carte indicateur d'humidité

HIC carte sur laquelle un produit chimique sensible à l'humidité est imprimé de telle sorte qu'il passe de sec à humide lorsque l'humidité relative indiquée est dépassée Note 1 à l'article: Cette note s'applique uniquement à la langue française.

3.10 vitesse de transmission de la vapeur d'eau

WVTR mesure de la perméabilité à l'humidité d'un matériau en film plastique, utilisée pour spécifier un sac barrière contre l'humidité (3.3) pour l'emballage à sec Note 1 à l'article: Cette note s'applique uniquement à la langue française.

4 Informations générales

4.1 Dispositifs sensibles à l'humidité

Certains matériaux, polymères plastiques et charges sont hygroscopiques et peuvent absorber l'humidité en fonction du temps et de l'environnement de stockage. L'humidité absorbée s'évapore pendant le chauffage rapide pendant le processus de refusion de la brasure, générant - pression dans le matériau, - déformation, - gonflement, - délamination, - fissuration, - dégradation de la connexion interne.

La pénétration d'humidité dans le matériau absorbant est généralement provoquée par l'exposition à l'air ambiant. L'absorption d'humidité ou la pénétration d'humidité dans les cavités peut conduire à des concentrations en humidité dans le dispositif suffisamment élevées pour provoquer une fissuration ou une délamination du dispositif pendant le processus de brasage (par exemple, « phénomène pop-corn »), ce qui peut affecter négativement la fiabilité.

NOTE Le « phénomène pop-corn » définit une contrainte interne qui provoque un gonflement de l'emballage, puis une fissuration avec un « pop » sonore.

L'humidité peut également influer sur la force d'adhérence des adhésifs, des joints d'étanchéité, des encapsulants, des plastiques avec revêtement galvanique, etc. L'exposition à l'humidité peut également induire le transport de contaminations ioniques dans le dispositif, augmentant ainsi le risque de défaillance du circuit due à la corrosion. Il est donc nécessaire de sécher les dispositifs sensibles à l'humidité (3.1), de les sceller dans un sac de protection contre l'humidité (3.3) et de les retirer immédiatement avant de les braser sur la carte de circuit imprimé. Le temps admissible, entre l'ouverture du sac de protection contre l'humidité (3.3) et le processus de brasage final, pendant lequel un dispositif peut rester non protégé dans un environnement dont le niveau d'humidité se rapproche des conditions réelles (par exemple, 30 °C/60 % HR) est une mesure de la sensibilité du dispositif à l'humidité ambiante. Cette durée est appelée durée de vie au sol (3.5).

4.2 Niveau de sensibilité à l'humidité (MSL)

Le niveau de sensibilité à l'humidité (3.2) (MSL) est déterminé à la température de classification, qui est fixée au-dessus des températures de brasage pratiques. La température de brasage réelle mesurée à la surface supérieure du composant doit donc être inférieure à la température de classification.

L'emballage, le stockage, la durée de vie au sol (3.5) et le prétraitement des dispositifs sensibles à l'humidité (3.1) avant d'être soumis aux processus de brasage par refusion sont identifiés par la LSM (3.2) (voir Article 5 et Tableau 1).

La méthode de classification des dispositifs en MSL (3.2) est décrite à l'Article 6.

4.3 Relation avec d'autres méthodes d'essais d'environnement (essais d'humidité)

Lors des essais d'humidité, par exemple comme dans l'IEC 60068‑2‑78 [4], les dispositifs sont soumis à essai soit non montés, soit montés (par exemple, soudés sur une carte d'essai). Ces essais détectent l'influence de l'humidité adsorbée ou absorbée sur les performances du dispositif (par exemple, caractéristiques électriques, effets de corrosion), mais ne peuvent pas détecter l'influence de l'humidité absorbée sur la sensibilité aux contraintes thermiques des processus de brasage.

L'objectif de la méthode d'essai décrite dans le présent document est de soumettre à essai la résistance des dispositifs à la chaleur de brasage en combinaison avec la charge d'humidité comme procédé de préconditionnement.

D'autres effets de l'humidité, tels que la détérioration des caractéristiques électriques ou des propriétés d'isolation, ne sont pas couverts par le présent document et doivent être soumis à essai séparément.

5 Évaluation de la sensibilité à l'humidité

5.1 Identification des dispositifs non sensibles à l'humidité

Les dispositifs non sensibles à l'humidité doivent être identifiés par analyse de la conception et des matériaux des dispositifs selon qu'ils peuvent absorber l'humidité ou selon que l'humidité peut pénétrer dans les cavités. Si les matériaux n'absorbent apparemment pas l'humidité, les dispositifs peuvent être déclarés par le fabricant comme non sensibles à l'humidité. Ces dispositifs non sensibles à l'humidité doivent être désignés comme étant de niveau « N ». Il n'existe pas d'exigences pour les dispositifs non sensibles à l'humidité.

5.2 Classification

Le mode opératoire de classification des dispositifs sensibles à l'humidité (3.1) en MSL (3.2) est décrit à l'Article 6. Les dispositifs sont classés à la température de classification appropriée choisie dans les Tableaux 3 et 4. Voir l'Annexe A pour la classification des ensembles semi-finis.

Le mode opératoire recommandé consiste à commencer l'essai au niveau de sensibilité à l'humidité le plus bas (3.2), que l'ensemble d'évaluation est raisonnablement censé satisfaire (d'après la connaissance d'autres ensembles d'évaluation similaires). Si les fournisseurs et les utilisateurs sont d'accord, les composants peuvent être classés à des températures autres que celles indiquées dans le Tableau 4. Si les conditions du Tableau 1 ou du Tableau 2 ne conviennent pas à un produit spécifique, d'autres conditions peuvent être appliquées conformément à l'accord entre les utilisateurs et les fournisseurs.

Tableau 1– Niveaux de sensibilité à l'humidité NIVEAU durée de Durée de vie au durée de Emballage de Dessiccan Indicateu vie au sol (3.5) conservat protection t r sol (3.5) condition ion (3.6) d'humidi durée (condition de té référence) 1 a ≤30 °C/85 % HR 12 mois ou Aucune exigence

comme b 2 a ≤30 °C/60 % HR No Facultatif spécifié MBB (3.3) type 1 , 1 an

par le <60 % HR dans MBB fournisseu (3.3) pas de préséchage r b c C2a 4 ≤30 °C/60 % HR Oui MBB (3.3) type 1 , Oui semaines <30 % HR dans MBB (3.3) pas de préséchage b 2a MBB (3.3) type 2 , <10 % HR dans MBB (3.3) préséchage b c C3 168 h ≤30 °C/60 % HR Oui MBB (3.3) type 1 , Oui <30 % HR dans MBB (3.3) pas de préséchage b

MBB (3.3) type 2 , <10 % HR dans MBB (3.3) préséchage b c 4 72 h ≤30 °C/60 % HR Oui MBB (3.3) type 2 , Oui <10 % HR dans MBB (3.3) préséchage c c 5 48 h ≤30 °C/60 % HR Oui MBB (3.3) type 2 , Oui <10 % HR dans MBB (3.3) préséchage La durée de vie au sol (3.5) peut être plus longue si les conditions d'environnement sont moins sévères que la condition de référence, ou plus courte si elles sont plus sévères. Une durée de conservation prolongée (3.6) peut faire l'objet d'un accord, mais nécessite de recalculer la quantité de déshydratant.

A Il convient que la somme du temps de stockage au sol et du temps de stockage ne dépasse pas la période de stockage maximale spécifiée par le fournisseur.

b La durée de conservation exigée (3.6) et l'humidité en condition de remplissage doivent être assurées par la quantité de déshydratant, calculée en utilisant le taux de transmission de la vapeur d'eau (3.10) (WVTR) du MBB appliqué (3.3). Pour la description du type MBB (3.3), voir le Tableau 5.

Indicateur d'humidité: HIC (3.9) ou déshydratant indicateur d'humidité (3.8).

6 Mode opératoire d'essai

6.1 Généralités

6.1.1 Composants de structure similaire

La classification peut être effectuée pour un groupe de composants de structure similaire. Des informations sur la similitude structurelle doivent être données dans la spécification applicable.

6.1.2 Essais de vérification et de validation

La spécification applicable doit décrire le nombre minimal d'éprouvettes à soumettre à essai. Il convient que le nombre minimal soit d'au moins 11 pièces.

NOTE Un échantillon de 11 pièces soumises à essai avec un nombre d'acceptation nul représente un pourcentage de tolérance du lot (LTPD) défectueux de 20 % avec un niveau de confiance (C.L.) de 90 %. Voir l'ISO 2859‑1 [5] pour plus d'informations.

6.1.3 Choix des conditions de trempe et du profil de température applicables

Les conditions d'immersion liées à la LSM (3.2) doivent être choisies dans le Tableau 2, le profil de température applicable pour la classification (Figure 1) dans le Tableau 3 et le Tableau 4.

6.2 Séchage

Sauf spécification contraire dans la spécification applicable, l'éprouvette doit être cuite à 125 °C ± 5 °C pendant au moins 24 h.

Toutefois, d'autres conditions de cuisson peuvent être appliquées, si elles sont confirmées par l'analyse du gain ou de la perte de masse décrite à l'Annexe B.

6.3 Trempage dans l'humidité

Tableau 2– Conditions de trempe dans l'humidité NIVEAU Temps a Alternative Condition d'immersion d'immersion (h) 1 (168 +5/−0) (85 ± 2) °C, (85 ± 5) % HR (336 +5/−0) h; (85 ± 2) °C, (60 ± 5) % HR 2 (168 +5/−0) (85 ± 2) °C, (60 ± 5) % HR – C2a (168 +5/−0) suivi (85 ± 2) °C, (30 ± 5) % HR, puis – de (672 +5/−0) (30 ± 2) °C, (60 ± 5) % HR 2a (696 + 5/−0) (30 ± 2) °C, (60 ± 5) % HR C3 (168 +5/−0) suivi (85 ± 2) °C, (30 ± 5) % HR, puis de (168 +5/−0) (30 ± 2) °C, (60 ± 5) % HR 3 (192 +5/−0) (30 ± 2) °C, (60 ± 5) % HR 4 (96 +2/−0) (30 ± 2) °C, (60 ± 5) % HR 5 (72 +2/−0) Dans les niveaux C2a et C3, la première étape de la condition de trempage correspond à la durée de conservation (3.6) (≤30 °C, ≤30 % HR, un an) dans le MBB (3.3) type 1. La deuxième étape de l'état d'immersion correspond à la durée de vie au sol (3.5) (comme dans l'IEC 60749‑20 [1]).

a Conditions de trempage selon la J-STD-020F [2]. Des conditions de trempe équivalentes accélérées du Tableau 4 de la J-STD-020F [2] peuvent également être appliquées si l'énergie d'activation est confirmée par le fabricant.

6.4 Charge de température

6.4.1 Profil de température de classification

Légende T Température minimale de préchauffage

T Température maximale de préchauffage

T Température du liquide

Température de classification Tc t Durée de préchauffage

t Temps au liquidus

t Temps compris entre ( – 5 °C) 3 Tc t Temps jusqu'à 4 Tc a Gradient de température de la pente croissante b Zone de préchauffage c Gradient de température de la pente décroissante Le gradient de température de la pente croissante ne doit pas dépasser 3 K/s et le gradient de température de la pente décroissante ne doit pas dépasser 6 K/s. Figure 1 – Profil de température de classification

Tableau 3– Paramètres du profil de température de classification Procédé de Sn-Pb (ou équivalent) SnAgCu (ou équivalent) Sn-Bi (ou équivalent) brasage T 100 °C 150 °C 100 °C

T 150 °C 200 °C 120 °C

t (60 à 120) s (60 à 120) s (30 à 90) s

T 183 °C 217 °C 139 °C

t (60 à 150) s (60 à 150) s (60 à 150) s

t 20 s 30 s 20 s

T Voir Tableau 4

t ≤6 min ≤8 min ≤4 min

Tableau 4 – Températures de classification T

Procédé de Epaisseur du Température de classification pour le volume du boîtier Tc brasage boîtier 3 3 3 <350 mm 350 mm à 2 000 >2 000 mm

mm mm °C °C °C

SnPb (ou <2,5 235 220 220 équivalent) ≥ 2,5 220 220 220 SnAgCu (ou <1,6 260 260 260 équivalent) 1,6 à 2,5 260 250 245 >2,5 250 245 245 b b >2,5 plus capacité non applicable 230 230 a thermique élevée Sn-Bi (ou Épaisseur et volume de l'emballage: 190 équivalent) [LTS] a Cette condition peut être appliquée aux dispositifs ayant une masse thermique élevée, pour lesquels la température maximale du boîtier n'atteint pas 245 °C lorsqu'il est brasé avec un profil typique des procédés de brasage utilisant une brasure en alliage SnAgCu, ou pour les dispositifs très sensibles à la température. La température maximale de l'emballage est mesurée à la surface du dispositif ou en tout autre point spécifié dans la spécification applicable.

b T mesuré au niveau de la borne du dispositif ou du joint de brasure doit atteindre la température et le temps

minimaux nécessaires pour qu'un alliage de brasure spécifique forme un joint de brasure.

6.4.2 Profil de température de classification pour les dispositifs spéciaux

Lorsque les profils de température de classification du Tableau 3 et du Tableau 4 ne sont pas applicables à un dispositif (par exemple, composants ayant une masse thermique ou une sensibilité thermique élevée), les profils de température de l'IEC 60068-2-58:2015 [6], Tableau 7, peuvent être utilisés. D'autres profils peuvent être spécifiés dans la spécification applicable conformément à l'accord entre l'utilisateur et le fournisseur. Pour plus d'informations, voir également J-STD 075A [7].

6.4.3 Reflux

L'échantillon doit être soumis à 3 cycles des conditions de refusion appropriées définies à la Figure 1, au Tableau 3 et au Tableau 4, en commençant dans un intervalle de temps de 15 min à 4 h après le retrait de l'enceinte de température/humidité. La période de rétablissement entre deux cycles successifs doit être le temps nécessaire pour que la température de l'éprouvette chute en dessous de 50 °C.

Si le temps écoulé entre le retrait de la chambre d'essai climatique et le reflux initial ne peut pas être respecté, les parties doivent être à nouveau sectionnées et trempées conformément à 6.2 et 6.3.

Toutes les températures se rapportent au centre de l'emballage, mesurées sur la surface du corps de l'emballage qui est tournée vers le haut pendant la refusion de l'assemblage (par exemple, orientation live-bug).

...