IEC 61000-4-4:2004/COR2:2007
(Corrigendum)Corrigendum 2 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
Corrigendum 2 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
Corrigendum 2 - Compatibilité électromagnétique (CEM) - Partie 4-4: Techniques d'essai et de mesure - Essais d'immunité aux transitoires électriques rapides en salves
General Information
- Status
- Published
- Publication Date
- 05-Jun-2007
- Technical Committee
- SC 77B - High frequency phenomena
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 30-Apr-2012
- Completion Date
- 14-Feb-2026
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard
TL 9000 QuEST Forum
Telecommunications quality management system.

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
Sponsored listings
Frequently Asked Questions
IEC 61000-4-4:2004/COR2:2007 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 2 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test". This standard covers: Corrigendum 2 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
Corrigendum 2 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-4:2004/COR2:2007 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61000-4-4:2004/COR2:2007 has the following relationships with other standards: It is inter standard links to IEC 61000-4-4:2004, IEC 61000-4-4:2004/COR1:2006, IEC 61000-4-4:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61000-4-4:2004/COR2:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61000-4-4
(Second edition – 2004)
Electromagnetic compatibility (EMC) –
Part 4-4: Testing and measurement techniques –
Electrical fast transient/burst immunity test
CORRIGENDUM 2
Page 25
6.2.2 Verification of the characteristics of the coupling/decoupling network
Replace the second paragraph by the following:
The waveform shall be verified at the common mode output of the coupling/decoupling network with
all outputs tied together and a single 50 Ω termination as shown in Figure 14. In addition to
verification of the waveform at the common mode output of the coupling/decoupling network, it is
recommended that each individual output be checked to ensure that all outputs are functional."
Signal from test generator
Decoupling
L
L
Termination
L
resistor
N
50 Ω
U
meas
PE
IEC 1033/07
Figure 14 – Verification of the waveform at the common mode output of the
coupling/decoupling network
th
Delete the 4 paragraph starting with “The functionality verification of ….”.
June 2007
CEI 61000-4-4
(Deuxième édition – 2004)
C
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...