Lamp controlgear - Part 1: General and safety requirements

This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp controlgear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included. This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to supplement or modify the corresponding clauses in part 1, to provide the relevant requirements for each type of product. This first edition of IEC 61347-1, together with parts 1 to 9 of IEC 61347-2, cancels and replaces IEC 60920, IEC 60922, IEC 60924, IEC 60926, IEC 60928 and IEC 61046, and constitute a minor revision. The relationship between the parts that make up IEC 61347-2 and the IEC standards they replace is detailed as follows: IEC 61347-2-1 replaces IEC 60926 IEC 61347-2-2 replaces IEC 61046 IEC 61347-2-3 replaces IEC 60928 IEC 61347-2-4 replaces IEC 60924, Section 3 IEC 61347-2-5 replaces IEC 60924, Section 4 IEC 61347-2-6 replaces IEC 60924, Section 5 IEC 61347-2-7 replaces IEC 60924, Section 6 IEC 61347-2-8 replaces IEC 60920 IEC 61347-2-9 replaces IEC 60922

Appareillages de lampes - Partie 1: Prescriptions générales et prescriptions de sécurité

La présente partie de la CEI 61347 spécifie les prescriptions générales et les prescriptions de sécurité pour les appareillages de lampes destinés à être utilisés sur des alimentations à courant continu jusqu'à 250 V et/ou sur des alimentations à courant alternatif jusqu'à 1000 V à 50 Hz ou 60 Hz. La présente norme traite aussi des appareillages de lampes pour les lampes qui ne sont pas encore normalisées. Les essais traités dans cette norme sont des essais de type. Les prescriptions pour les essais individuels des appareillages de lampes pendant la production ne sont pas incluses. La présente partie 1 doit être utilisée conjointement avec la partie 2 appropriée, qui comporte les articles complétant ou modifiant les articles correspondants de la partie 1, afin d'établir les règles complètes pour chaque type d'appareil. Cette première édition de la CEI 61347-1, ainsi que les parties 1 à 9 de la CEI 61347-2 annulent et remplacent la CEI 60920, la CEI 60922, la CEI 60924, la CEI 60926, la CEI 60928, et la CEI 61046, et constituent une révision mineure. La correspondance entre les parties composant la CEI 61347-2 et les normes qu'elles remplacent est détaillée ci-dessous: la CEI 61347-2-1 remplace la CEI 60926 la CEI 61347-2-2 remplace la CEI 61046 la CEI 61347-2-3 remplace la CEI 60928 la CEI 61347-2-4 remplace la CEI 60924, Section 3 la CEI 61347-2-5 remplace la CEI 60924, Section 4 la CEI 61347-2-6 remplace la CEI 60924, Section 5 la CEI 61347-2-7 remplace la CEI 60924, Section 6 la CEI 61347-2-8 remplace la CEI 60920 la CEI 61347-2-9 remplace la CEI 60922

General Information

Status
Published
Publication Date
12-Nov-2003
Technical Committee
Drafting Committee
Current Stage
DELPUB - Deleted Publication
Start Date
31-Jan-2007
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 61347-1:2000 - Lamp controlgear - Part 1: General and safety requirements Released:10/13/2000 Isbn:2831854946
English and French language
117 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 61347-1:2000+AMD1:2003 CSV - Lamp controlgear - Part 1: General and safety requirements Released:11/13/2003 Isbn:283187260X
English and French language
125 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
61347-1
INTERNATIONAL
Première édition
STANDARD
First edition
2000-10
Appareillages de lampes –
Partie 1:
Prescriptions générales et prescriptions
de sécurité
Lamp controlgear –
Part 1:
General and safety requirements

Numéro de référence
Reference number
CEI/IEC 61347-1:2000
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and

base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61347-1
INTERNATIONAL
Première édition
STANDARD
First edition
2000-10
Appareillages de lampes –
Partie 1:
Prescriptions générales et prescriptions
de sécurité
Lamp controlgear –
Part 1:
General and safety requirements

 IEC 2000 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
XA
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61347-1 © CEI:2000
SOMMAIRE
Pages
AVANT-PROPOS . 6

INTRODUCTION . 12

Articles
1 Domaine d'application . 14

2 Références normatives. 14
3 Définitions. 16
4 Prescriptions générales . 24
5 Généralités sur les essais . 24
6 Classification .26
7 Marquage.26
7.1 Indications à préciser . 26
7.2 Durabilité et lisibilité du marquage. 28
8 Bornes . 28
9 Dispositions en vue de la mise à la terre de protection. 30
10 Protection contre le contact accidentel avec des parties actives. 30
11 Résistance à l'humidité et isolement . 32
12 Rigidité diélectrique. 32
13 Essai d'endurance thermique des enroulements des ballasts . 34
14 Conditions de défaut . 40
15 Construction. 44
15.1 Bois, coton, soie, papier et matériaux fibreux similaires . 44
15.2 Les cartes imprimées . 44
16 Lignes de fuite et distances dans l'air . 46
17 Vis, parties transportant le courant et connexions . 50
18 Résistance à la chaleur, au feu et aux courants de cheminement. 50
19 Résistance à la corrosion . 52
Annexe A (normative) Essai ayant pour objet de déterminer si une partie conductrice
est une partie active pouvant entraîner un choc électrique . 58

Annexe B (normative) Prescriptions particulières pour les appareillages de lampes
à protection thermique .60
Annexe C (normative) Prescriptions particulières pour les appareillages de lampes
électroniques avec dispositifs de protection contre la surchauffe . 74
Annexe D (normative) Prescriptions pour les essais d'échauffement des appareillages
de lampes à protection thermique . 80
Annexe E (normative) Usage de constantes S différentes de 4 500 pour les essais t . 86
w
Annexe F (normative) Enceinte à l'abri des courants d'air. 92
Annexe G (normative) Explications concernant le calcul des valeurs des impulsions
de tension . 94
Annexe H (normative) Essais. 104
Bibliographie . 116

61347-1 © IEC:2000 – 3 –
CONTENTS
Page
FOREWORD . 7

INTRODUCTION . 13

Clause
1 Scope . 15

2 Normative references. 15
3 Definitions. 17
4 General requirements . 25
5 General notes on tests. 25
6 Classification .27
7 Marking. 27
7.1 Items to be marked . 27
7.2 Durability and legibility of marking . 29
8 Terminals. 29
9 Provisions for protective earthing. 31
10 Protection against accidental contact with live parts. 31
11 Moisture resistance and insulation . 33
12 Electric strength.33
13 Thermal endurance test for windings of ballasts. 35
14 Fault conditions . 41
15 Construction .45
15.1 Wood, cotton, silk, paper and similar fibrous material . 45
15.2 Printed circuits. 45
16 Creepage distances and clearances. 47
17 Screws, current-carrying parts and connections . 51
18 Resistance to heat, fire and tracking . 51
19 Resistance to corrosion. 53
Annex A (normative) Test to establish whether a conductive part is a live part which
may cause an electric shock. 59

Annex B (normative) Particular requirements for thermally protected lamp controlgear. 61
Annex C (normative) Particular requirements for electronic lamp controlgear with
means of protection against overheating . 75
Annex D (normative) Requirements for carrying out the heating tests of thermally
protected lamp controlgear. 81
Annex E (normative) Use of constant S other than 4 500 in t tests. 87
w
Annex F (normative) Draught-proof enclosure . 93
Annex G (normative) Explanation of the derivation of the values of pulse voltages . 95
Annex H (normative) Tests . 105
Bibliography . 117

– 4 – 61347-1 © CEI:2000
Pages
Figure 1 – Relation entre la température de l’enroulement et la durée de l’essai

d’endurance . . 54

Figure 2 – Lignes de fuite entre conducteurs sur cartes imprimées qui ne sont pas reliés

conductivement au réseau d'alimentation. 56

Figure D.1 – Exemple d'enceinte chauffante pour les ballasts avec protection thermique. 84

Figure E.1 – Contrôle de la valeur revendiquée de S . 90

Figure G.1 – Circuit pour la mesure de l’énergie des impulsions de courte durée. 100

Figure G.2 – Circuit convenant à la production et à l’application de tensions d’impulsion

de longue durée. 102
Figure H.1 – Disposition pour l’essai d’échauffement . 114
Tableau 1 – Tension d'essai de rigidité diélectrique. 34
Tableau 2 – Températures théoriques d'essai pour les ballasts soumis à un essai
d'endurance d'une durée de 30 jours . 38
Tableau 3 – Distances minimales pour tensions alternatives sinusoïdales (50/60 Hz) . 48
Tableau 4 – Distances minimales pour tensions impulsionnelles non sinusoïdales. 48
Tableau B.1 – Fonctionnement avec protection thermique. 68
Tableau B.2 – Fonctionnement avec protection thermique. 70

61347-1 © IEC:2000 – 5 –
Page
Figure 1 – Relation between winding temperature and endurance test duration. 55

Figure 2 – Creepage distances between conductors on printed boards not conductively

connected to the supply mains . 57

Figure D.1 – Exemple of heating enclosure for thermally protected ballasts. 85

Figure E.1 – Assessment of claimed value of S . 91

Figure G.1 – Circuit for measuring short-duration pulse energy . 101

Figure G.2 – Suitable circuit for producing and applying long-duration pulses . 103

Figure H.1 – Test arrangement for heating test . 115
Table 1 – Electric strength test voltage. 35
Table 2 – Theoretical test temperatures for ballasts subjected to an endurance test
duration of 30 days. 39
Table 3 – Minimum distances for a.c. (50/60 Hz) sinusoidal voltages . 49
Table 4 – Minimum distances for non-sinusoidal pulse voltages . 49
Table B.1 – Thermal protection operation. 69
Table B.2 – Thermal protection operation. 71

– 6 – 61347-1 © CEI:2000
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

___________
APPAREILLAGES DE LAMPES –
Partie 1: Prescriptions générales et prescriptions de sécurité

AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61347-1 a été établie par le sous-comité 34C: Appareils
auxiliaires pour lampes, du comité d’études 34 de la CEI: Lampes et équipements associés.
Cette première édition de la CEI 61347-1, ainsi que les parties 1 à 9 de la CEI 61347-2
annulent et remplacent la CEI 60920, la CEI 60922, la CEI 60924, la CEI 60926, la CEI 60928,
et la CEI 61046, et constituent une révision mineure.

La correspondance entre les parties composant la CEI 61347-2 et les normes qu’elles
remplacent est détaillée ci-dessous:
la CEI 61347-2-1 remplace la CEI 60926
la CEI 61347-2-2 remplace la CEI 61046
la CEI 61347-2-3 remplace la CEI 60928
la CEI 61347-2-4 remplace la CEI 60924, Section 3
la CEI 61347-2-5 remplace la CEI 60924, Section 4
la CEI 61347-2-6 remplace la CEI 60924, Section 5
la CEI 61347-2-7 remplace la CEI 60924, Section 6
la CEI 61347-2-8 remplace la CEI 60920
la CEI 61347-2-9 remplace la CEI 60922

61347-1 © IEC:2000 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
LAMP CONTROLGEAR –
Part 1: General and safety requirements

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-1 has been prepared by subcommittee 34C: Auxiliaries for
lamps, of IEC technical committee 34: Lamps and related equipment.
This first edition of IEC 61347-1, together with parts 1 to 9 of IEC 61347-2, cancels and
replaces IEC 60920, IEC 60922, IEC 60924, IEC 60926, IEC 60928 and IEC 61046, and
constitute a minor revision.
The relationship between the parts that make up IEC 61347-2 and the IEC standards they
replace is detailed as follows:

IEC 61347-2-1 replaces IEC 60926
IEC 61347-2-2 replaces IEC 61046
IEC 61347-2-3 replaces IEC 60928
IEC 61347-2-4 replaces IEC 60924, Section 3
IEC 61347-2-5 replaces IEC 60924, Section 4
IEC 61347-2-6 replaces IEC 60924, Section 5
IEC 61347-2-7 replaces IEC 60924, Section 6
IEC 61347-2-8 replaces IEC 60920
IEC 61347-2-9 replaces IEC 60922

– 8 – 61347-1 © CEI:2000
Le texte de cette norme est issu des documents suivants:

FDIS Rapport de vote
34C/508/FDIS 34C/522/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.

Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.

La présente partie 1 doit être utilisée conjointement avec la partie 2 appropriée, qui comporte
les articles complétant ou modifiant les articles correspondants de la partie 1, afin d'établir les
règles complètes pour chaque type d'appareil.
NOTE Dans la présente norme, les caractères suivants sont employés:
– Prescriptions proprement dites: caractères romains.
– Modalités d'essais: caractères italiques.
– NOTES: petits caractères romains.
Les annexes A, B, C, D, E, F, G et H font partie intégrante de cette norme.
La CEI 61347, comprend les parties suivantes, présentées sous le titre général: Appareillages
de lampes:
– Partie 1: Prescriptions générales et prescriptions de sécurité
– Partie 2-1: Prescriptions particulières pour les dispositifs d'amorçage (autres que starters
à lueur)
– Partie 2-2: Prescriptions particulières pour les convertisseurs abaisseurs électroniques
alimentés en courant continu ou alternatif pour lampes à incandescence
– Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant
alternatif pour lampes fluorescentes
– Partie 2-4: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage général
– Partie 2-5: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des transports en commun
– Partie 2-6: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des aéronefs
– Partie 2-7: Prescriptions particulières pour les ballasts électroniques alimentés en courant

continu pour l'éclairage de secours
– Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
– Partie 2-9: Prescriptions particulières pour les ballasts pour lampes à décharge (à l'exclu-
sion des lampes fluorescentes)
– Partie 2-10: Prescriptions particulières pour les onduleurs et les convertisseurs électro-
niques destinés à l’alimentation en haute fréquence des lampes tubulaires à décharge à
démarrage à froid (tubes néon)
– Partie 2-11: Prescriptions particulières pour les circuits électroniques divers pour usage
1)
avec les luminaires
________
1)
A publier.
61347-1 © IEC:2000 – 9 –
The text of this standard is based on the following documents:

FDIS Report on voting
34C/508/FDIS 34C/522/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.

This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to
supplement or modify the corresponding clauses in part 1, to provide the relevant
requirements for each type of product.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
Annexes A, B, C, D, E, F, G and H form an integral part of this standard.
IEC 61347, consists of the following parts under the general title Lamp controlgear:
– Part 1: General and safety requirements
– Part 2-1: Particular requirements for starting devices (other than glow starters)
– Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors
for filament lamps
– Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
– Part 2-4: Particular requirements for d.c. electronic ballasts for general lighting
– Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport
lighting
– Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
– Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency
lighting
– Part 2-8: Particular requirements for ballasts for fluorescent lamps
– Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent
lamps)
– Part 2-10: Particular requirements for electronic invertors and convertors for high-
frequency operation of cold start tubular discharge lamps (neon tubes)
– Part 2-11: Particular requirements for miscellaneous electronic circuits used with
1)
luminaires
________
1)
To be published.
– 10 – 61347-1 © CEI:2000
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2003.

A cette date, la publication sera

• reconduite;
• supprimée;
• remplacée par une édition révisée, ou

• amendée.
61347-1 © IEC:2000 – 11 –
The committee has decided that the contents of this publication will remain unchanged

until 2003. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or

• amended.
– 12 – 61347-1 © CEI:2000
INTRODUCTION
Cette première édition de la CEI 61347-1, publiée conjointement avec les parties 2-1 à 2-9,

constitue une modification éditoriale de la CEI 60926, la CEI 61046, la CEI 60928, la

CEI 60924, la CEI 60920 et la CEI 60922. La présentation en parties publiées séparément faci-

litera les futures modifications et révisions. Des prescriptions supplémentaires seront ajoutées
si et quand le besoin en sera reconnu.

Les différentes parties qui composent la CEI 61347-2 sont équivalentes, sur le plan technique,

aux normes originales de la CEI sur lesquelles elles sont fondées. Ainsi les produits qui ont

été reconnus conformes à la CEI 60920, à la CEI 60922, à la CEI 60924, à la CEI 60926, à

la CEI 60928 et à la CEI 61046 peuvent être considérés comme conformes aux prescriptions
des parties composant la CEI 61347-2, qui les remplacent. De la même manière, dans le cas
où d'autres normes requièrent la conformité à la CEI 60920, à la CEI 60922, à la CEI 60924, à
la CEI 60926, à la CEI 60928 et à la CEI 61046, la conformité aux parties de la CEI 61347-2
équivalentes est considérée comme satisfaisant à ces exigences.
La présente partie de la CEI 61347 donne un ensemble de prescriptions générales et de
sécurité et d’essais qui sont considérés comme pouvant s'appliquer de manière générale à la
plupart des types d'appareillages de lampes et qui peuvent être rappelés, selon les besoins,
dans les parties composant la CEI 61347-2. La présente partie 1 ne peut donc pas être consi-
dérée comme étant une spécification en elle-même pour n'importe quel type d'appareillage
de lampes, et ses dispositions s'appliquent seulement aux types particuliers d'appareillages de
lampes, dans le domaine déterminé par la partie 2 appropriée de la CEI 61347.
Les parties qui composent la CEI 61347-2, en faisant référence à un quelconque des articles
de la présente partie, spécifient le domaine dans lequel cet article est applicable et l'ordre dans
lequel les essais seront à effectuer; elles incluent aussi des prescriptions supplémentaires, si
nécessaire. L'ordre dans lequel les articles de la présente partie sont numérotés n'a pas de
signification particulière car l'ordre dans lequel leurs dispositions s'appliquent est déterminé
pour chaque type d'appareillage de lampe par la partie 2 appropriée de la série CEI 61347-2.
Toutes ces parties sont autonomes et, par conséquent, ne contiennent pas de références les
unes aux autres.
Quand les prescriptions de l'un quelconque des articles de la présente partie de la CEI 61347
sont citées en référence dans les parties composant la CEI 61347-2 par la phrase «Les
prescriptions de l'article n de la CEI 61347-1 s'appliquent», cette phrase sera interprétée
comme signifiant que toutes les prescriptions de cet article de la partie 1 s'appliquent, excepté
éventuellement celles qui d'évidence ne s'appliquent pas au type particulier d'appareillage de
lampe couvert par la partie 2 considérée.
Les appareillages de lampes qui sont conformes au texte de cette norme ne seront pas
nécessairement jugés comme étant conformes aux principes de sécurité de la norme si,

lorsqu'ils sont examinés et essayés, il est trouvé qu'ils ont d'autres caractéristiques qui altèrent
le niveau de sécurité objet de ces prescriptions.
Un appareillage de lampe présentant des dispositions de construction différentes ou utilisant
des matériaux différents de ceux détaillés dans les prescriptions de cette norme peut être
examiné et soumis aux essais dans l'esprit de la prescription et, s'il est trouvé qu'il est prati-
quement équivalent, peut être jugé comme satisfaisant aux principes de sécurité de la norme.
Les prescriptions de performance pour les appareillages de lampes sont le sujet des normes
CEI suivantes: CEI 60921, CEI 60923, CEI 60925, CEI 60927, CEI 60929, et CEI 61047 en
fonction du type d’appareillage de lampe.
NOTE Les prescriptions de sécurité garantissent que les équipements électriques construits selon ces prescrip-
tions sont, lorsqu'ils sont correctement montés et entretenus et qu'ils sont utilisés pour les applications auxquelles
ils sont destinés, sans danger pour les personnes, les animaux domestiques ou les biens.
Des prescriptions pour des appareillages électroniques de lampes pour d'autres types de
lampes feront l'objet de normes séparées, si le besoin apparaît.

61347-1 © IEC:2000 – 13 –
INTRODUCTION
This first edition of IEC 61347-1, published in conjunction with parts 2-1 to 2-9, represents an

editorial review IEC 60926, IEC 61046, IEC 60928, IEC 60924, IEC 60920 and IEC 60922.

The formatting into separately published parts provides for ease of future amendments and

revisions. Additional requirements will be added as and when a need for them is recognized.

The different parts which make up IEC 61347-2 are technically equivalent to the original IEC

standards on which they are based. As such, products which have been shown to comply with
IEC 60920, IEC 60922, IEC 60924, IEC 60926, IEC 60928 and IEC 61046 can be considered

as complying with the requirements of the part 2 of IEC 61347 which replaces them. Similarly,

where other standards call for compliance with IEC 60920, IEC 60922, IEC 60924, IEC 60926,
IEC 60928 and IEC 61046, conformity with the equivalent part 2 of IEC 61347 is considered to
meet this requirement.
This part of IEC 61347 provides a set of general and safety requirements and tests which are
considered to be generally applicable to most types of lamp controlgear and which can be
called up as required by the different parts that make up IEC 61347-2. This part 1 is thus not
to be regarded as a specification in itself for any type of lamp controlgear, and its provisions
apply only to particular types of lamp controlgear, to the extent determined by the appropriate
part 2 of IEC 61347.
The parts which make up IEC 61347-2, in referring to any of the clauses of this part, specify
the extent to which such a clause is applicable and the order in which the tests are to be
performed; they also include additional requirements as necessary. The order in which the
clauses of this part are numbered has no particular significance, as the order in which their
provisions apply is determined for each type of lamp controlgear by the appropriate part 2 of
IEC 61347-2 series. All such parts are self-contained and therefore do not contain references
to each other.
Where the requirements of any of the clauses of this part of IEC 61347 are referred to in
the various parts that make up IEC 61347-2 by the phrase "The requirements of clause n of
IEC 61347-1 apply", this phrase will be interpreted as meaning that all requirements of the
clause in question of part 1 apply, except any which are clearly inapplicable to the particular
type of lamp controlgear covered by the part 2 concerned.
Lamp controlgear which complies with the text of this standard will not necessarily be judged
to comply with the safety principles of the standard if, when examined and tested, it is found
to have other features which impair the level of safety covered by these requirements.
Lamp controlgear employing materials or having forms of construction differing from those

detailed in the requirements of this standard may be examined and tested according to the
intent of the requirement and, if found to be substantially equivalent, may be judged to comply
with the safety principles of the standard.
Performance requirements for lamp controlgear are the subject of IEC 60921, IEC 60923,
IEC 60925, IEC 60927, IEC 60929 and IEC 61047 as appropriate for the type of lamp
controlgear.
NOTE Safety requirements ensure that electrical equipment constructed in accordance with these requirements
does not endanger the safety of persons, domestic animals or property when properly installed and maintained and
used in applications for which it was intended.
Requirements for electronic lamp controlgear for other types of lamps will be the subject of a
separate standard, as the need arises.

– 14 – 61347-1 © CEI:2000
APPAREILLAGES DE LAMPES –
Partie 1: Prescriptions générales et prescriptions de sécurité

1 Domaine d'application
La présente partie de la CEI 61347 spécifie les prescriptions générales et les prescriptions

de sécurité pour les appareillages de lampes destinés à être utilisés sur des alimentations à

courant continu jusqu'à 250 V et/ou sur des alimentations à courant alternatif jusqu'à 1 000 V
à 50 Hz ou 60 Hz.
La présente norme traite aussi des appareillages de lampes pour les lampes qui ne sont pas
encore normalisées.
Les essais traités dans cette norme sont des essais de type. Les prescriptions pour les essais
individuels des appareillages de lampes pendant la production ne sont pas incluses.
Les prescriptions pour les semi-luminaires sont données dans la CEI 60598.
En complément aux prescriptions générales données dans la présente norme, l'annexe B
donne des prescriptions générales et de sécurité applicables aux appareillages de lampes à
protection thermique.
L’annexe C comporte les prescriptions générales et de sécurité complémentaires qui
s’appliquent aux appareillages de lampes avec protection contre la surchauffe.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 61347.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications ne
s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente partie de
la CEI 61347 sont invitées à rechercher la possibilité d’appliquer les éditions les plus récentes
des normes indiquées ci-après. Pour les références non datées, la dernière édition du
document normatif en référence s’applique. Les membres de la CEI et de l’ISO possèdent le
registre des Normes internationales en vigueur.
CEI 60065, Appareils audio, vidéo et appareils électroniques analogues – Exigences de sécurité
CEI 60081, Lampes à fluorescence à deux culots – Prescriptions de performances

CEI 60112, Méthode pour déterminer des indices de résistance et de tenue au cheminement
des matériaux isolants solides dans des conditions humides
CEI 60249 (toutes les parties), Matériaux de base pour circuits imprimés
CEI 60249-1, Matériaux de base pour circuits imprimés – Première partie: Méthodes d'essai
CEI 60317-0-1, Spécifications pour types particuliers de fils de bobinage – Partie 0:
Prescriptions générales – Section 1: Fil de section circulaire en cuivre émaillé
CEI 60417 (toutes les parties), Symboles graphiques utilisables sur le matériel
CEI 60529, Degrés de protection procurés par les enveloppes (Code IP)
CEI 60598-1, Luminaires – Partie 1: Prescriptions générales et essais
CEI 60691, Protecteurs thermiques – Prescriptions et guide d'application

61347-1 © IEC:2000 – 15 –
LAMP CONTROLGEAR –
Part 1: General and safety requirements

1 Scope
This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use

on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.

This standard also covers lamp controlgear for lamps which are not yet standardized.
Tests dealt with in this standard are type tests. Requirements for testing individual lamp
controlgear during production are not included.
Requirements for semi-luminaires are given in IEC 60598.
In addition to the requirements given in this standard, annex B sets out general and safety
requirements applicable to thermally protected lamp controlgear.
Annex C sets out additional general and safety requirements as they apply to electronic lamp
controlgear with means of protection against overheating.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 61347. For dated references, subsequent
amendments to, or revisions of, any of these publications do not apply. However, parties to
agreements based on this part of IEC 61347 are encouraged to investigate the possibility of
applying the most recent editions of the normative documents indicated below. For undated
references, the latest edition of the normative document referred to applies. Members of IEC
and ISO maintain registers of currently valid International Standards.
IEC 60065, Audio, video and similar electronic apparatus – Safety requirements
IEC 60081, Double-capped fluorescent lamps – Performance specifications
IEC 60112, Method for determining the comparative and the proof tracking indices of solid
insulating materials under moist conditions

IEC 60249 (all parts), Base materials for printed circuits
IEC 60249-1, Base materials for printed circuits – Part 1: Test methods
IEC 60317-0-1, Specifications for particular types of winding wires – Part 0: General
requirements – Section 1: Enamelled round copper wire
IEC 60417 (all parts), Graphical symbols for use on equipment
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 60598-1, Luminaires – Part 1: General requirements and tests
IEC 60691, Thermal-links – Requirements and application guide

– 16 – 61347-1 © CEI:2000
CEI 60695-2-1/0, Essais relatifs aux risques du feu – Partie 2: Méthodes d’essai – Section 1

feuille 0: Méthodes d’essai au fil incandescent – Généralités

CEI 60695-2-2, Essais relatifs aux risques du feu – Partie 2: Méthodes d’essai – Section 2:

Essai au brûleur-aiguille
CEI 60730-2-3, Dispositifs de commande électrique automatiques à usage domestique et

analogue – Deuxième partie: Règles particulières pour les protecteurs thermiques des ballasts

pour lampes tubulaires à fluorescence

CEI 60901, Lampes à fluorescence à culot unique – Prescrip
...


NORME CEI
INTERNATIONALE IEC
61347-1
INTERNATIONAL
Edition 1.1
STANDARD
2003-11
Edition 1:2000 consolidée par l’amendement 1:2003
Edition 1:2000 consolidated with amendment 1:2003
Appareillages de lampes –
Partie 1:
Prescriptions générales et prescriptions
de sécurité
Lamp controlgear –
Part 1:
General and safety requirements

Numéro de référence
Reference number
CEI/IEC 61347-1:2000+A1:2003
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For

devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1

exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
x Site web de la CEI (www.iec.ch) x IEC Web Site (www.iec.ch)
x Catalogue des publications de la CEI x Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
x IEC Just Published x IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
x Service clients x Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61347-1
INTERNATIONAL
Edition 1.1
STANDARD
2003-11
Edition 1:2000 consolidée par l’amendement 1:2003
Edition 1:2000 consolidated with amendment 1:2003
Appareillages de lampes –
Partie 1:
Prescriptions générales et prescriptions
de sécurité
Lamp controlgear –
Part 1:
General and safety requirements

© IEC 2003 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
XB
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue

FI 01 Interprétation de l’Article 9

CEI 61347-1: 2000 Première édition

Appareillages de lampes - Partie 1: Prescriptions générales et prescriptions de sécurité

FEUILLE D’INTERPRETATION
La restriction "Toutefois, si l'appareillage de lampe comporte une borne de terre, celle-ci doit

être utilisée uniquement pour la mise à la terre de cet appareillage" n'est pas applicable aux

appareillages de lampe indépendants.

Les appareillages de lampe indépendants peuvent avoir des bornes de terre qui ne sont pas

destinées seulement à leur propre mise à la terre.

Appareillage électronique
de commande indépendant
Luminaire
L
N
PE
Lampe
Par exemple : pontet en métal
massif ou en fil de 1,5 mm
Autre appareillage
électronique
de commande
IEC  1423/06
septembre 2006  ICS 29.140.99 Texte anglais au verso

IS 01 Interpretation of Clause 9

IEC 61347-1: 2000 First edition

Lamp controlgear - Part 1: General and safety requirements

INTERPRETATION SHEET
The restriction “However, if a lamp controlgear has an earthing terminal, this terminal shall only be

used for earthing the lamp controlgear” is not applicable for independent lamp controlgear.

Independent lamp controlgear may have earthing terminals which are not only for their own earthing.

Independant ECG
Luminaire
L
N
PE
Lamp
For example : massive metal block
or 1,5 mm wire
Further ECGs
IEC  1423/06
September 2006  ICS 29.140.99 French text overleaf

– 2 – 61347-1 © CEI:2000+A1:2003

SOMMAIRE
AVANT-PROPOS . 6

INTRODUCTION .12

1 Domaine d'application.16

2 Références normatives.16

3 Définitions.18

4 Prescriptions générales.26
5 Généralités sur les essais .26
6 Classification.28
7 Marquage.28
8 Bornes.30
9 Dispositions en vue de la mise à la terre de protection.32
10 Protection contre le contact accidentel avec des parties actives.32
11 Résistance à l'humidité et isolement.34
12 Rigidité diélectrique.34
13 Essai d'endurance thermique des enroulements des ballasts.36
14 Conditions de défaut .42
15 Construction.46
16 Lignes de fuite et distances dans l'air .48
17 Vis, parties transportant le courant et connexions.52
18 Résistance à la chaleur, au feu et aux courants de cheminement .52
19 Résistance à la corrosion .54
Annexe A (normative) Essai ayant pour objet de déterminer si une partie conductrice
est une partie active pouvant entraîner un choc électrique .60
Annexe B (normative) Prescriptions particulières pour les appareillages de lampes à
protection thermique.62
Annexe C (normative) Prescriptions particulières pour les appareillages de lampes
électroniques avec dispositifs de protection contre la surchauffe.76
Annexe D (normative) Prescriptions pour les essais d'échauffement des appareillages

de lampes à protection thermique .82
Annexe E (normative) Usage de constantes S différentes de 4 500 pour les essais t .88
w
Annexe F (normative) Enceinte à l'abri des courants d'air .94
Annexe G (normative) Explications concernant le calcul des valeurs des impulsions de
tension .96
Annexe H (normative) Essais.106
Annexe I (normative) Prescriptions complémentaires pour les ballasts magnétiques à
incorporer avec isolation double ou renforcée .118
Bibliographie .124

61347-1 © IEC:2000+A1:2003 – 3 –

CONTENTS
FOREWORD . 7

INTRODUCTION .13

1 Scope.17

2 Normative references.17

3 Definitions.19

4 General requirements.27
5 General notes on tests.27
6 Classification.29
7 Marking.29
8 Terminals.31
9 Provisions for protective earthing.33
10 Protection against accidental contact with live parts .33
11 Moisture resistance and insulation .35
12 Electric strength.35
13 Thermal endurance test for windings of ballasts.37
14 Fault conditions.43
15 Construction.47
16 Creepage distances and clearances .49
17 Screws, current-carrying parts and connections.53
18 Resistance to heat, fire and tracking.53
19 Resistance to corrosion.55
Annex A (normative) Test to establish whether a conductive part is a live part which
may cause an electric shock .61
Annex B (normative) Particular requirements for thermally protected lamp controlgear .63
Annex C (normative) Particular requirements for electronic lamp controlgear with
means of protection against overheating .77
Annex D (normative) Requirements for carrying out the heating tests of thermally

protected lamp controlgear.83
Annex E (normative) Use of constant S other than 4 500 in t tests.89
w
Annex F (normative) Draught-proof enclosure .95
Annex G (normative) Explanation of the derivation of the values of pulse voltages.97
Annex H (normative) Tests.107
Annex I (normative) Additional requirements for built-in magnetic ballasts with double
or reinforced insulation.119
Bibliography.125

– 4 – 61347-1 © CEI:2000+A1:2003

Figure 1 – Relation entre la température de l’enroulement et la durée de l’essai

d’endurance .56

Figure 2 – Lignes de fuite entre conducteurs sur cartes imprimées qui ne sont pas reliés

conductivement au réseau d'alimentation.58

Figure D.1 – Exemple d'enceinte chauffante pour les ballasts avec protection thermique.86

Figure E.1 – Contrôle de la valeur revendiquée de S.92

Figure G.1 – Circuit pour la mesure de l’énergie des impulsions de courte durée.102

Figure G.2 – Circuit convenant à la production et à l’application de tensions d’impulsion

de longue durée .104

Figure H.1 – Disposition pour l’essai d’échauffement .116
Tableau 1 – Tension d'essai de rigidité diélectrique .36
Tableau 2 – Températures théoriques d'essai pour les ballasts soumis à un essai
d'endurance d'une durée de 30 jours .40
Tableau 3 – Distances minimales pour tensions alternatives sinusoïdales (50/60 Hz) .50
Tableau 4 – Distances minimales pour tensions impulsionnelles non sinusoïdales .50
Tableau B.1 – Fonctionnement avec protection thermique.70
Tableau B.2 – Fonctionnement avec protection thermique.72

61347-1 © IEC:2000+A1:2003 – 5 –

Figure 1 – Relation between winding temperature and endurance test duration.57

Figure 2 – Creepage distances between conductors on printed boards not conductively
connected to the supply mains .59

Figure D.1 – Exemple of heating enclosure for thermally protected ballasts .87

Figure E.1 – Assessment of claimed value of S.93

Figure G.1 – Circuit for measuring short-duration pulse energy .103

Figure G.2 – Suitable circuit for producing and applying long-duration pulses .105

Figure H.1 – Test arrangement for heating test .117

Table 1 – Electric strength test voltage .37
Table 2 – Theoretical test temperatures for ballasts subjected to an endurance test
duration of 30 days .41
Table 3 – Minimum distances for a.c. (50/60 Hz) sinusoidal voltages .51
Table 4 – Minimum distances for non-sinusoidal pulse voltages .51
Table B.1 – Thermal protection operation.71
Table B.2 – Thermal protection operation.73

– 6 – 61347-1 © CEI:2000+A1:2003

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

___________
APPAREILLAGES DE LAMPES –
Partie 1: Prescriptions générales et prescriptions de sécurité

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.

La Norme internationale CEI 61347-1 a été établie par le sous-comité 34C: Appareils
auxiliaires pour lampes, du comité d’études 34 de la CEI: Lampes et équipements associés.
La correspondance entre les parties composant la CEI 61347-2 et les normes qu’elles
remplacent est détaillée ci-dessous:
la CEI 61347-2-1 remplace la CEI 60926
la CEI 61347-2-2 remplace la CEI 61046
la CEI 61347-2-3 remplace la CEI 60928
la CEI 61347-2-4 remplace la CEI 60924, Section 3
la CEI 61347-2-5 remplace la CEI 60924, Section 4
la CEI 61347-2-6 remplace la CEI 60924, Section 5
la CEI 61347-2-7 remplace la CEI 60924, Section 6
la CEI 61347-2-8 remplace la CEI 60920
la CEI 61347-2-9 remplace la CEI 60922

61347-1 © IEC:2000+A1:2003 – 7 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
LAMP CONTROLGEAR –
Part 1: General and safety requirements

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-1 has been prepared by subcommittee 34C: Auxiliaries for
lamps, of IEC technical committee 34: Lamps and related equipment.

The relationship between the parts that make up IEC 61347-2 and the IEC standards they
replace is detailed as follows:
IEC 61347-2-1 replaces IEC 60926
IEC 61347-2-2 replaces IEC 61046
IEC 61347-2-3 replaces IEC 60928
IEC 61347-2-4 replaces IEC 60924, Section 3
IEC 61347-2-5 replaces IEC 60924, Section 4
IEC 61347-2-6 replaces IEC 60924, Section 5
IEC 61347-2-7 replaces IEC 60924, Section 6
IEC 61347-2-8 replaces IEC 60920
IEC 61347-2-9 replaces IEC 60922

– 8 – 61347-1 © CEI:2000+A1:2003

La présente version consolidée de la CEI 61347-1 est issue de la première édition (2000)
[documents 34C/508/FDIS et 34C/522/RVD] et de son amendement 1 (2003) [documents
34C/604/FDIS et 34C/616/RVD].
Elle porte le numéro d'édition 1.1.

Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.

La présente partie 1 doit être utilisée conjointement avec la partie 2 appropriée, qui comporte
les articles complétant ou modifiant les articles correspondants de la partie 1, afin d'établir les
règles complètes pour chaque type d'appareil.
NOTE Dans la présente norme, les caractères suivants sont employés:
– Prescriptions proprement dites: caractères romains.
– Modalités d'essais: caractères italiques.
– NOTES: petits caractères romains.
Les annexes A, B, C, D, E, F, G, H et I font partie intégrante de cette norme.
La CEI 61347 comprend les parties suivantes, présentées sous le titre général: Appareillages
de lampes:
– Partie 1: Prescriptions générales et prescriptions de sécurité
– Partie 2-1: Prescriptions particulières pour les dispositifs d'amorçage (autres que starters
à lueur)
– Partie 2-2: Prescriptions particulières pour les convertisseurs abaisseurs électroniques
alimentés en courant continu ou alternatif pour lampes à incandescence
– Partie 2-3: Prescriptions particulières pour les ballasts électroniques alimentés en courant
alternatif pour lampes fluorescentes
– Partie 2-4: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage général
– Partie 2-5: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des transports en commun
– Partie 2-6: Prescriptions particulières pour les ballasts électroniques alimentés en courant
continu pour l'éclairage des aéronefs
– Partie 2-7: Prescriptions particulières pour les ballasts électroniques alimentés en courant

continu pour l'éclairage de secours
– Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
– Partie 2-9: Prescriptions particulières pour les ballasts pour lampes à décharge (à l'exclu-
sion des lampes fluorescentes)
– Partie 2-10: Prescriptions particulières pour les onduleurs et les convertisseurs électro-
niques destinés à l’alimentation en haute fréquence des lampes tubulaires à décharge à
démarrage à froid (tubes néon)
– Partie 2-11: Prescriptions particulières pour les circuits électroniques divers pour usage
1)
avec les luminaires
________
1)
A publier.
61347-1 © IEC:2000+A1:2003 – 9 –

This consolidated version of IEC 61347-1 is based on the first edition (2000) [documents
34C/508/FDIS and 34C/522/RVD] and its amendment 1 (2003) [documents 34C/604/FDIS and
34C/616/RVD].
It bears the edition number 1.1.

A vertical line in the margin shows where the base publication has been modified by
amendment 1.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.

This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to
supplement or modify the corresponding clauses in part 1, to provide the relevant
requirements for each type of product.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
Annexes A, B, C, D, E, F, G, H and I form an integral part of this standard.
IEC 61347 consists of the following parts under the general title Lamp controlgear:
– Part 1: General and safety requirements
– Part 2-1: Particular requirements for starting devices (other than glow starters)
– Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors
for filament lamps
– Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
– Part 2-4: Particular requirements for d.c. electronic ballasts for general lighting
– Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport
lighting
– Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
– Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency
lighting
– Part 2-8: Particular requirements for ballasts for fluorescent lamps
– Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent
lamps)
– Part 2-10: Particular requirements for electronic invertors and convertors for high-
frequency operation of cold start tubular discharge lamps (neon tubes)
– Part 2-11: Particular requirements for miscellaneous electronic circuits used with
1)
luminaires
________
1)
To be published.
– 10 – 61347-1 © CEI:2000+A1:2003

Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2005.
A cette date, la publication sera

• reconduite;
• supprimée;
• remplacée par une édition révisée, ou

• amendée.
61347-1 © IEC:2000+A1:2003 – 11 –

The committee has decided that the contents of this publication will remain unchanged
until 2005. At this date, the publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or

• amended.
– 12 – 61347-1 © CEI:2000+A1:2003

INTRODUCTION
Cette première édition de la CEI 61347-1, publiée conjointement avec les parties 2-1 à 2-9,

constitue une modification éditoriale de la CEI 60926, la CEI 61046, la CEI 60928, la

CEI 60924, la CEI 60920 et la CEI 60922. La présentation en parties publiées séparément faci-

litera les futures modifications et révisions. Des prescriptions supplémentaires seront ajoutées

si et quand le besoin en sera reconnu.

Les différentes parties qui composent la CEI 61347-2 sont équivalentes, sur le plan technique,

aux normes originales de la CEI sur lesquelles elles sont fondées. Ainsi les produits qui ont

été reconnus conformes à la CEI 60920, à la CEI 60922, à la CEI 60924, à la CEI 60926, à

la CEI 60928 et à la CEI 61046 peuvent être considérés comme conformes aux prescriptions
des parties composant la CEI 61347-2, qui les remplacent. De la même manière, dans le cas
où d'autres normes requièrent la conformité à la CEI 60920, à la CEI 60922, à la CEI 60924, à
la CEI 60926, à la CEI 60928 et à la CEI 61046, la conformité aux parties de la CEI 61347-2
équivalentes est considérée comme satisfaisant à ces exigences.
La présente partie de la CEI 61347 donne un ensemble de prescriptions générales et de
sécurité et d’essais qui sont considérés comme pouvant s'appliquer de manière générale à la
plupart des types d'appareillages de lampes et qui peuvent être rappelés, selon les besoins,
dans les parties composant la CEI 61347-2. La présente partie 1 ne peut donc pas être consi-
dérée comme étant une spécification en elle-même pour n'importe quel type d'appareillage
de lampes, et ses dispositions s'appliquent seulement aux types particuliers d'appareillages de
lampes, dans le domaine déterminé par la partie 2 appropriée de la CEI 61347.
Les parties qui composent la CEI 61347-2, en faisant référence à un quelconque des articles
de la présente partie, spécifient le domaine dans lequel cet article est applicable et l'ordre dans
lequel les essais seront à effectuer; elles incluent aussi des prescriptions supplémentaires, si
nécessaire. L'ordre dans lequel les articles de la présente partie sont numérotés n'a pas de
signification particulière car l'ordre dans lequel leurs dispositions s'appliquent est déterminé
pour chaque type d'appareillage de lampe par la partie 2 appropriée de la série CEI 61347-2.
Toutes ces parties sont autonomes et, par conséquent, ne contiennent pas de références les
unes aux autres.
Quand les prescriptions de l'un quelconque des articles de la présente partie de la CEI 61347
sont citées en référence dans les parties composant la CEI 61347-2 par la phrase «Les
prescriptions de l'article n de la CEI 61347-1 s'appliquent», cette phrase sera interprétée
comme signifiant que toutes les prescriptions de cet article de la partie 1 s'appliquent, excepté
éventuellement celles qui d'évidence ne s'appliquent pas au type particulier d'appareillage de
lampe couvert par la partie 2 considérée.
Les appareillages de lampes qui sont conformes au texte de cette norme ne seront pas

nécessairement jugés comme étant conformes aux principes de sécurité de la norme si,
lorsqu'ils sont examinés et essayés, il est trouvé qu'ils ont d'autres caractéristiques qui altèrent
le niveau de sécurité objet de ces prescriptions.
Un appareillage de lampe présentant des dispositions de construction différentes ou utilisant
des matériaux différents de ceux détaillés dans les prescriptions de cette norme peut être
examiné et soumis aux essais dans l'esprit de la prescription et, s'il est trouvé qu'il est prati-
quement équivalent, peut être jugé comme satisfaisant aux principes de sécurité de la norme.
Les prescriptions de performance pour les appareillages de lampes sont le sujet des normes
CEI suivantes: CEI 60921, CEI 60923, CEI 60925, CEI 60927, CEI 60929, et CEI 61047 en
fonction du type d’appareillage de lampe.
NOTE Les prescriptions de sécurité garantissent que les équipements électriques construits selon ces prescrip-
tions sont, lorsqu'ils sont correctement montés et entretenus et qu'ils sont utilisés pour les applications auxquelles
ils sont destinés, sans danger pour les personnes, les animaux domestiques ou les biens.

61347-1 © IEC:2000+A1:2003 – 13 –

INTRODUCTION
This first edition of IEC 61347-1, published in conjunction with parts 2-1 to 2-9, represents an

editorial review IEC 60926, IEC 61046, IEC 60928, IEC 60924, IEC 60920 and IEC 60922.

The formatting into separately published parts provides for ease of future amendments and

revisions. Additional requirements will be added as and when a need for them is recognized.

The different parts which make up IEC 61347-2 are technically equivalent to the original IEC

standards on which they are based. As such, products which have been shown to comply with

IEC 60920, IEC 60922, IEC 60924, IEC 60926, IEC 60928 and IEC 61046 can be considered

as complying with the requirements of the part 2 of IEC 61347 which replaces them. Similarly,

where other standards call for compliance with IEC 60920, IEC 60922, IEC 60924, IEC 60926,
IEC 60928 and IEC 61046, conformity with the equivalent part 2 of IEC 61347 is considered to
meet this requirement.
This part of IEC 61347 provides a set of general and safety requirements and tests which are
considered to be generally applicable to most types of lamp controlgear and which can be
called up as required by the different parts that make up IEC 61347-2. This part 1 is thus not
to be regarded as a specification in itself for any type of lamp controlgear, and its provisions
apply only to particular types of lamp controlgear, to the extent determined by the appropriate
part 2 of IEC 61347.
The parts which make up IEC 61347-2, in referring to any of the clauses of this part, specify
the extent to which such a clause is applicable and the order in which the tests are to be
performed; they also include additional requirements as necessary. The order in which the
clauses of this part are numbered has no particular significance, as the order in which their
provisions apply is determined for each type of lamp controlgear by the appropriate part 2 of
IEC 61347-2 series. All such parts are self-contained and therefore do not contain references
to each other.
Where the requirements of any of the clauses of this part of IEC 61347 are referred to in
the various parts that make up IEC 61347-2 by the phrase "The requirements of clause n of
IEC 61347-1 apply", this phrase will be interpreted as meaning that all requirements of the
clause in question of part 1 apply, except any which are clearly inapplicable to the particular
type of lamp controlgear covered by the part 2 concerned.
Lamp controlgear which complies with the text of this standard will not necessarily be judged
to comply with the safety principles of the standard if, when examined and tested, it is found
to have other features which impair the level of safety covered by these requirements.
Lamp controlgear employing materials or having forms of construction differing from those
detailed in the requirements of this standard may be examined and tested according to the

intent of the requirement and, if found to be substantially equivalent, may be judged to comply
with the safety principles of the standard.
Performance requirements for lamp controlgear are the subject of IEC 60921, IEC 60923,
IEC 60925, IEC 60927, IEC 60929 and IEC 61047 as appropriate for the type of lamp
controlgear.
NOTE Safety requirements ensure that electrical equipment constructed in accordance with these requirements
does not endanger the safety of persons, domestic animals or property when properly installed and maintained and
used in applications for which it was intended.

– 14 – 61347-1 © CEI:2000+A1:2003

Des prescriptions pour des appareillages électroniques de lampes pour d'autres types de
lampes feront l'objet de normes séparées, si le besoin apparaît.

NOTE L’appareillage peut se présenter sous la forme d’un circuit imprimé et peut incorporer ce qui suit:

– appareillage;
– douille(s);
– commutateur(s);
– bornes pour l’alimentation.
Il convient que l’appareillage de lampe soit conforme à cette norme.

Il convient que les douilles, commutateurs et bornes pour l’alimentation soient conformes à leurs normes
respectives.
61347-1 © IEC:2000+A1:2003 – 15 –

Requirements for electronic lamp controlgear for other types of lamps will be the subject of a
separate standard, as the need arises.

NOTE Controlgear can consist of a printed circuit board and may incorporate the following:

– controlgear;
– lampholder(s);
– switch(es);
– supply terminals.
The lamp controlgear should comply with this standard.

The lampholders(s), switch(es) and supply terminals should comply with their own standards.

– 16 – 61347-1 © CEI:2000+A1:2003

APPAREILLAGES DE LAMPES –
Partie 1: Prescriptions générales et prescriptions de sécurité

1 Domaine d'application
La présente partie de la CEI 61347 spécifie les prescriptions générales et les prescriptions

de sécurité pour les appareillages de lampes destinés à être utilisés sur des alimentations à

courant continu jusqu'à 250 V et/ou sur des alimentations à courant alternatif jusqu'à 1 000 V

à 50 Hz ou 60 Hz.
La présente norme traite aussi des appareillages de lampes pour les lampes qui ne sont pas
encore normalisées.
Les essais traités dans cette norme sont des essais de type. Les prescriptions pour les essais
individuels des appareillages de lampes pendant la production ne sont pas incluses.
Les prescriptions pour les semi-luminaires sont données dans la CEI 60598.
En complément aux prescriptions générales données dans la présente norme, l'annexe B
donne des prescriptions générales et de sécurité applicables aux appareillages de lampes à
protection thermique.
L’annexe C comporte les prescriptions générales et de sécurité complémenta
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...