Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 3: Radiated, radio-frequency, electromagnetic field immunity test

Applies to the immunity of electrical and electronic equipment to radiated electromagnetic energy. Establishes test levels and the required test procedures. Establishes a common reference for evaluating the performance of electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.

Compatibilité électromagnétique (CEM) - Partie 4: Techniques d'essai et de mesure - Section 3: Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques

Traite de l'immunité des matériels électriques et électroniques à l'énergie électromagnétique rayonnée. Définit les niveaux d'essai et les procédures d'essai nécessaires. Etablit une référence commune d'évaluation des performances des matériels électriques et électroniques soumis à des champs électromagétiques aux fréquences radioélectriques.

General Information

Status
Published
Publication Date
24-Apr-2001
Current Stage
DELPUB - Deleted Publication
Start Date
06-Mar-2002
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 61000-4-3:1995+AMD1:1998 CSV - Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test Released:11/27/1998 Isbn:2831845688
English and French language
73 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 61000-4-3:1995+AMD1:1998+AMD2:2000 CSV - Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test Released:4/25/2001 Isbn:2831856752
English and French language
77 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME
CEI
INTERNATIONALE
IEC
61000-4-3
INTERNATIONAL
Edition 1.1
STANDARD
1998-11
Edition 1:1995 consolidée par l’amendement 1:1998
Edition 1:1995 consolidated with amendment 1:1998
Compatibilité électromagnétique (CEM) –
Partie 4-3:
Techniques d’essai et de mesure –
Essai d’immunité aux champs électromagnétiques
rayonnés aux fréquences radioélectriques
Electromagnetic compatibility (EMC) –
Part 4-3:
Testing and measurement techniques –
Radiated, radio-frequency, electromagnetic field
immunity test
Numéro de référence
Reference number
CEI/IEC 61000-4-3:1995+A1:1998

Numéros des publications Numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. issued with a designation in the 60000 series.

Publications consolidées Consolidated publications

Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant des amendements sont disponibles. including amendments are available. For example,

Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to

indiquent respectivement la publication de base, la the base publication, the base publication incor-
publication de base incorporant l’amendement 1, et porating amendment 1 and the base publication

la publication de base incorporant les amendements 1 incorporating amendments 1 and 2.

et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept under
constamment revu par la CEI afin qu'il reflète l'état constant review by the IEC, thus ensuring that the
actuel de la technique. content reflects current technology.
Des renseignements relatifs à la date de re- Information relating to the date of the reconfirmation of
confirmation de la publication sont disponibles dans the publication is available in the IEC catalogue.
le Catalogue de la CEI.
Les renseignements relatifs à ces révisions, à l'établis- Information on the revision work, the issue of revised
sement des éditions révisées et aux amendements editions and amendments may be obtained from
peuvent être obtenus auprès des Comités nationaux de la IEC National Committees and from the following
CEI et dans les documents ci-dessous: IEC sources:
• «Site web»* de la CEI • IEC web site*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
(Catalogue en ligne)* (On-line catalogue)*
• Bulletin de la CEI • IEC Bulletin
Disponible sur le «site web»* de la CEI Available both at the IEC web site* and
et comme périodique imprimé as a printed periodical
Terminologie, symboles graphiques Terminology, graphical and letter
et littéraux symbols
En ce qui concerne la terminologie générale, le lec-teur For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire Electro- IEC 60050: International Electrotechnical Vocabulary
technique International (VEI). (IEV).
Pour les symboles graphiques, les symboles littéraux et For graphical symbols, and letter symbols and signs
les signes d'usage général approuvés par la CEI, le approved by the IEC for general use, readers are
referred to publications IEC 60027: Letter symbols to
lecteur consultera la CEI 60027: Symboles littéraux à
utiliser en électrotechnique, la CEI 60417: Symboles be used in electrical technology, IEC 60417: Graphical
graphiques utilisables sur le matériel. Index, relevé et symbols for use on equipment. Index, survey and
compilation of the single sheets
compilation des feuilles individuelles, et la CEI 60617: and IEC 60617:
Symboles graphiques pour schémas. Graphical symbols for diagrams.

* Voir adresse «site web» sur la page de titre. * See web site address on title page.

NORME
CEI
INTERNATIONALE
IEC
61000-4-3
INTERNATIONAL
Edition 1.1
STANDARD
1998-11
Edition 1:1995 consolidée par l’amendement 1:1998
Edition 1:1995 consolidated with amendment 1:1998

Compatibilité électromagnétique (CEM) –
Partie 4-3:
Techniques d’essai et de mesure –
Essai d’immunité aux champs électromagnétiques
rayonnés aux fréquences radioélectriques
Electromagnetic compatibility (EMC) –
Part 4-3:
Testing and measurement techniques –
Radiated, radio-frequency, electromagnetic field
immunity test
 IEC 1998 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
W
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61000-4-3 © CEI:1995+A.1:1998

SOMMAIRE
Pages
AVANT-PROPOS . 4

INTRODUCTION . 6

Articles
1 Domaine d'application et objet. 8
2 Références normatives. 8
3 Généralités. 10
4 Définitions. 10
5 Niveaux d'essai. 16
6 Matériel d'essai. 18
7 Montage d'essai. 24
8 Procédures d'essai. 26
9 Résultats d'essai et compte rendu d'essai . 30
Figures
1 Définition du niveau d'essai et des formes d'onde apparaissant à la sortie
du générateur de signaux (niveau d'essai 1) . 32
2 Exemple d'installation d'essai . 34
3 Etalonnage du champ. 36
4 Etalonnage du champ, dimensions de la zone uniforme . 38
5 Exemple de montage d'essai pour un matériel posé au sol . 40
6 Exemple de montage d'essai pour un matériel de table. 42
Annexes
A Justification du choix de la modulation pour les essais relatifs à la protection contre
les émissions aux fréquences radioélectriques des radiotéléphones numériques . 44
B Antennes émettrices. 54
C Utilisation des chambres anéchoïques. 56
D Autres méthodes d'essai – Cellules TEM et lignes TEM à plaques . 58
E Autres installations d'essai . 60
F Informations destinées aux comités de produits sur le choix des niveaux d’essai . 62
G Mesures spéciales pour les transmetteurs fixes . 68
H Choix des méthodes d'essai . 68
I Description de l'environnement. 70

61000-4-3 © IEC:1995+A.1:1998 – 3 –

CONTENTS
Page
FOREWORD. 5

INTRODUCTION . 7

Clause
1 Scope and object . 9
2 Normative references. 9
3 General. 11
4 Definitions. 11
5 Test levels. 17
6 Test equipment. 19
7 Test set-up. 25
8 Test procedures. 27
9 Test results and test report. 31
Figures
1 Definition of the test level and the waveshapes occurring at the output of the signal
generator . 33
2 Example of suitable test facility. 35
3 Calibration of field . 37
4 Calibration of field, dimensions of the uniform area. 39
5 Example of test set-up for floor-standing equipment . 41
6 Example of test set-up for table-top equipment . 43
Annexes
A Rationale for the choice of modulation for tests related to the protection against
RF emissions from digital radio telephones. 45
B Field generating antennas . 55
C Use of anechoic chambers . 57

D Other test methods – TEM cells and striplines . 59
E Other test facilities . 61
F Guidance for product committees on the selection of test levels. 63
G Special measures for fixed transmitters . 69
H Selection of test methods . 69
I Description of the environment . 71

– 4 – 61000-4-3 © CEI:1995+A.1:1998

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

_________
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –

Partie 4-3: Techniques d'essai et de mesure –

Essai d'immunité aux champs électromagnétiques rayonnés

aux fréquences radioélectriques

AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61000-4-3 a été établie par le sous-comité 65A: Aspects systèmes,
du comité d'études 65 de la CEI: Mesure et commande dans les processus industriels.
Elle constitue la section 3 de la partie 4 de la norme CEI 61000 et remplace la première édition
de la CEI 60801-3, parue en 1984. Elle a le statut de publication fondamentale en CEM en
accord avec le guide 107 de la CEI.

La présente version consolidée de la CEI 61000-4-3 est issue de la première édition (1995) et
de son amendement 1 (1998) [documents 77B/234, 77B/235/FDIS et 77B/238, 77B/239/RVD].
Elle porte le numéro d'édition 1.1.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1.
Les annexes A à I sont données uniquement à titre d'information.

61000-4-3 © IEC:1995+A.1:1998 – 5 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –

Radiated, radio-frequency, electromagnetic field immunity test

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-4-3 has been prepared by subcommittee 65A: System
aspects, of IEC technical committee 65: Industrial-process measurement and control.
It forms section 3 of part 4 of IEC 61000 and replaces the first edition of IEC 60801-3 issued in
1984. It has the status of a basic EMC publication in accordance with IEC Guide 107.
This consolidated version of IEC 61000-4-3 is based on the first edition (1995) and its

amendment 1 (1998) [documents 77B/234, 77B/235/FDIS et 77B/238, 77B/239/RVD].
It bears the edition number 1.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1.
Annexes A to I are for information only.

– 6 – 61000-4-3 © CEI:1995+A.1:1998

INTRODUCTION
La présente norme fait partie de la série des normes 61000 de la CEI, selon la répartition

suivante:
Partie 1: Généralités
Considérations générales (introduction, principes fondamentaux)

Définitions, terminologie
Partie 2: Environnement
Description de l'environnement
Classification de l'environnement
Niveaux de compatibilité
Partie 3: Limites
Limites d'émission
Limites d'immunité (dans la mesure où elles ne relèvent pas des comités de produit)
Partie 4: Techniques d'essai et de mesure
Techniques de mesure
Techniques d'essai
Partie 5: Guide d'installation et d'atténuation
Guide d'installation
Méthodes et dispositifs d'atténuation
Partie 9: Divers
Chaque partie est à son tour subdivisée en sections qui seront publiées soit comme Normes
internationales soit comme rapports techniques.
La présente section constitue une norme internationale qui traite des prescriptions en matière
d'immunité et des procédures d'essai qui s'appliquent aux champs électromagnétiques
rayonnés aux fréquences radioélectriques.

61000-4-3 © IEC:1995+A.1:1998 – 7 –

INTRODUCTION
This standard is part of the IEC 61000 series, according to the following structure:

Part 1: General
General considerations (introduction, fundamental principles)

Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of the product committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 9: Miscellaneous
Each part is further subdivided into sections which are to be published either as International
Standards or as technical reports.
This section is an International Standard which gives immunity requirements and test
procedures related to radiated, radio-frequency, electromagnetic fields.

– 8 – 61000-4-3 © CEI:1995+A.1:1998

COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –

Partie 4-3: Techniques d'essai et de mesure –

Essai d'immunité aux champs électromagnétiques rayonnés

aux fréquences radioélectriques

1 Domaine d'application et objet

La présente section de la CEI 61000-4 traite de l'immunité des matériels électriques et
électroniques à l'énergie électromagnétique rayonnée. Elle définit les niveaux d'essai et les
procédures d'essai nécessaires.
Cette section a pour objet d'établir une référence commune d'évaluation des performances des
matériels électriques et électroniques soumis à des champs électromagnétiques aux
fréquences radioélectriques.
La présente section traite des essais d’immunité relatifs aux cas généraux. Des considérations
particulières sont consacrées à la protection contre les émissions aux fréquences radio-
électriques des radiotéléphones numériques.
NOTE – Cette section définit des méthodes d'essai pour mesurer l'incidence des rayonnements électromagnétiques
sur le matériel concerné. La simulation et les mesures des rayonnements électromagnétiques ne sont pas
suffisamment exactes pour déterminer quantitativement les effets. Les méthodes d'essai définies ont été
principalement mises au point pour obtenir une bonne reproductibilité des résultats sur différentes installations
d'essai en vue d'une analyse qualitative des effets.
Cette section ne vise pas à spécifier les essais devant s'appliquer à des appareils ou systèmes
particuliers. Le but principal est de donner une référence de base d'ordre général à tous les
comités de produits CEI concernés. Les comités de produits (ou les utilisateurs et fabricants
de matériel) restent responsables du choix approprié des essais et du niveau de sévérité à
appliquer à leur matériel.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 61000.
Au moment de la publication, les éditions indiquées étaient en vigueur. Tout document normatif
est sujet à révision, et les parties prenantes aux accords fondés sur la présente partie de la
CEI 61000 sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes

des documents normatifs indiqués ci-après. Les membres de la CEI et de l'ISO possèdent le
registre des Normes internationales en vigueur.
CEI 60050(161):1990, Vocabulaire Electrotechnique International (VEI) – Chapitre 161:
Compatibilité électromagnétique
CEI 61000-4-6:1996, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d'essai
et de mesure – Section 6: Essai d'immunité aux perturbations conduites, induites par les
champs électromagnétiques aux fréquences radioélectriques

61000-4-3 © IEC:1995+A.1:1998 – 9 –

ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –

Radiated, radio-frequency, electromagnetic field immunity test

1 Scope and object
This section of IEC 61000-4 is applicable to the immunity of electrical and electronic equipment
to radiated electromagnetic energy. It establishes test levels and the required test procedures.
The object of this section is to establish a common reference for evaluating the performance of
electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.
This section deals with immunity tests related to general purposes. Particular considerations
are devoted to the protection against radiofrequency emissions from digital radio telephones.
NOTE – Test methods are defined in this section for measuring the effect that electromagnetic radiation has on the
equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for
quantitative determination of effects. The test methods defined are structured for the primary objective of
establishing adequate repeatability of results at various test facilities for qualitative analysis of effects.
This section does not intend to specify the tests to be applied to particular apparatus or
systems. Its main aim is to give a general basic reference to all concerned product committees
of the IEC. The product committees (or users and manufacturers of equipment) remain
responsible for the appropriate choice of the tests and the severity level to be applied to their
equipment.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 61000. At the time of publication, the editions indicated
were valid. All normative documents are subject to revision, and parties to agreements based
on this part of IEC 61000 are encouraged to investigate the possibility of applying the most
recent editions of the normative documents indicated below. Members of IEC and ISO maintain
registers of currently valid International Standards.
International Electrotechnical Vocabulary (IEV) – Chapter 161:
IEC 60050(161):1990,
Electromagnetic compatibility
Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
IEC 61000-4-6:1996,
techniques – Section 6: Immunity to conducted disturbances induced by radio-frequency fields

– 10 – 61000-4-3 © CEI:1995+A.1:1998

3 Généralités
La plupart des matériels électroniques sont, dans une certaine mesure, perturbés par les
rayonnements électromagnétiques. Ces rayonnements proviennent souvent de petits
émetteurs/récepteurs radio portatifs utilisés par le personnel d'exploitation, de maintenance et

de sécurité, des émetteurs fixes de radio et télévision, des émetteurs radio utilisés à bord des

véhicules et de diverses sources électromagnétiques industrielles.

Ces dernières années, il a été constaté une augmentation significative de l’utilisation de

radiotéléphones et autres radiotransmetteurs fonctionnant à des fréquences comprises entre

0,8 GHz et 3 GHz. Beaucoup de ces services utilisent des méthodes de modulation avec une
enveloppe non constante (par exemple AMRT).
En dehors de cette énergie électromagnétique rayonnée de façon délibérée, il existe
également des rayonnements parasites provoqués par des appareils de soudure, des
thyristors, des éclairages fluorescents, des commutateurs de charges inductives, etc. Pour la
plus grande part, ces perturbations se manifestent sous forme de perturbations électriques
conduites et, en tant que telles, sont traitées dans d'autres parties de la présente norme. Les
méthodes utilisées pour prévenir les effets des champs électromagnétiques réduisent aussi
normalement les effets provoqués par ces sources.
L'environnement électromagnétique est déterminé par la valeur du champ électromagnétique
(la valeur du champ est exprimée en volts par mètre). Les structures environnantes ou la
proximité d'autres matériels déformant et/ou réfléchissant les ondes électromagnétiques
rendent la mesure du champ difficile sans l'utilisation d'instruments sophistiqués et son calcul
n'est pas aisé avec les équations et les formules classiques.
4 Définitions
Pour les besoins de la présente section de la CEI 61000-4, les définitions suivantes et celles
de la CEI 60050(161) s'appliquent.
4.1
modulation d'amplitude
opération par laquelle on fait varier l'amplitude d'une onde porteuse suivant une loi spécifiée
4.2
chambre anéchoïque
enceinte blindée revêtue d'un matériau absorbant les ondes radioélectriques afin de réduire les
réflexions provenant des surfaces internes
4.2.1
chambre totalement anéchoïque
enceinte blindée dont les surfaces internes sont totalement revêtues d'un matériau absorbant
4.2.2
chambre semi-anéchoïque
enceinte blindée dont toutes les surfaces internes sont revêtues d'un matériau absorbant à
l'exception du sol, qui doit être réfléchissant (plan de sol)
4.2.3
chambre semi-anéchoïque modifiée
chambre semi-anéchoïque dans laquelle des absorbants supplémentaires sont disposés sur le
plan de sol
61000-4-3 © IEC:1995+A.1:1998 – 11 –

3 General
Most electronic equipment is, in some manner, affected by electromagnetic radiation. This
radiation is frequently generated by such sources as the small hand-held radio transceivers
that are used by operating, maintenance and security personnel, fixed-station radio and

television transmitters, vehicle radio transmitters, and various industrial electromagnetic

sources.
In recent years there has been a significant increase in the use of radio telephones and other

radio transmitters operating at frequencies between 0,8 GHz and 3 GHz. Many of these

services use modulation techniques with a non-constant envelope (e.g. TDMA).
In addition to electromagnetic energy deliberately generated, there is also spurious radiation
caused by devices such as welders, thyristors, fluorescent lights, switches operating inductive
loads, etc. For the most part, this interference manifests itself as conducted electrical inter-
ference and, as such, is dealt with in other parts of this standard. Methods employed to prevent
effects from electromagnetic fields will normally also reduce the effects from these sources.
The electromagnetic environment is determined by the strength of the electromagnetic field
(field strength in volts per metre). The field strength is not easily measured without
sophisticated instrumentation nor is it easily calculated by classical equations and formulae
because of the effect of surrounding structures or the proximity of other equipment that will
distort and/or reflect the electromagnetic waves.
4 Definitions
For the purposes of this section of IEC 61000-4, the following definitions, together with those in
IEC 60050(161) apply.
4.1
amplitude modulation
process by which the amplitude of a carrier wave is varied following a specified law
4.2
anechoic chamber
shielded enclosure which is lined with radio-frequency absorbers to reduce reflections from the
internal surfaces
4.2.1
fully anechoic chamber
shielded enclosure whose internal surfaces are totally lined with anechoic material
4.2
semi-anechoic chamber
shielded enclosure where all internal surfaces are covered with anechoic material with the
exception of the floor, which shall be reflective (ground plane)
4.2.3
modified semi-anechoic chamber
semi-anechoic chamber which has additional absorbers installed on the ground plane

– 12 – 61000-4-3 © CEI:1995+A.1:1998

4.3
antenne
transducteur servant soit à l'émission de puissance aux fréquences radioélectriques dans

l'espace à partir d'une source de signaux, soit à intercepter l'arrivée d'un champ électro-

magnétique en le convertissant en un signal électrique

4.4
symétriseur
dispositif transformant une tension symétrique par rapport à la masse en une tension

asymétrique ou inversement. [VEI 161-04-34]

4.5
ondes entretenues
ondes électromagnétiques dont les oscillations successives sont identiques en régime établi et
qui peuvent être interrompues ou modulées pour transmettre des informations
4.6
onde électromagnétique
énergie rayonnante créée par l'oscillation d'une charge électrique caractérisée par l'oscillation
des champs électrique et magnétique
4.7
champ lointain
région dans laquelle la puissance surfacique émise par une antenne obéit approximativement à
la loi de l'inverse du carré de la distance.
λ π λ
Pour un dipôle, cela correspond à des distances supérieures à /2 où désigne la longueur
d'onde du rayonnement
4.8
valeur du champ
le terme «valeur du champ» n'est utilisé que pour les mesures effectuées en champ lointain.
Ces mesures peuvent concerner soit la composante électrique, soit la composante magnétique
du champ et peuvent être exprimées en V/m, A/m ou W/m , chacune de ces unités pouvant
être convertie dans les autres unités
NOTE – Pour les mesures effectuées en champ proche, on utilisera le terme de «champ électrique» ou de «champ
magnétique» suivant que le champ résultant, électrique ou magnétique, est mesuré. Dans cette région du champ, la
relation entre les valeurs des champs électrique et magnétique et la distance est complexe et difficile à prévoir
puisqu'elle dépend des configurations spécifiques. Dans la mesure où il n'est généralement pas possible de
déterminer la relation de phase spatio-temporelle des différentes composantes du champ complexe, la puissance
surfacique est, de la même manière, indéterminée.
4.9
bande de fréquences
gamme continue de fréquences située entre deux limites
4.10
champ d’induction
champ électrique et/ou magnétique prédominant à une distance d < λ/2π, où λ désigne la
longueur d’onde, et où les dimensions physiques de la source sont nettement plus petites que
la distance d
4.11
isotrope
ayant des propriétés d'égale valeur dans toutes les directions
4.12
polarisation
orientation du vecteur de champ électrique d'un champ rayonné

61000-4-3 © IEC:1995+A.1:1998 – 13 –

4.3
antenna
transducer which either emits radio-frequency power into space from a signal source or

intercepts an arriving electromagnetic field, converting it into an electrical signal

4.4
balun
device for transforming an unbalanced voltage to a balanced voltage or vice versa [IEV 161-04-34]

4.5
continuous waves (CW)
electromagnetic waves, the successive oscillations of which are identical under steady-state
conditions, which can be interrupted or modulated to convey information
4.6
electromagnetic (EM) wave
radiant energy produced by the oscillation of an electric charge characterized by oscillation of
the electric and magnetic fields
4.7
far field
region where the power flux density from an antenna approximately obeys an inverse square
law of the distance.
For a dipole this corresponds to distances greater than λ/2π, where λ is the wavelength of the
radiation
4.8
field strength
the term "field strength" is applied only to measurements made in the far field. The
measurement may be of either the electric or the magnetic component of the field and may be
expressed as V/m, A/m or W/m ; any one of these may be converted into the others
NOTE – For measurements made in the near field, the term "electric field strength" or "magnetic field strength" is
used according to whether the resultant electric or magnetic field, respectively, is measured. In this field region, the
relationship between the electric and magnetic field strength and distance is complex and difficult to predict, being
dependent on the specific configuration involved. Inasmuch as it is not generally feasible to determine the time and
space phase relationship of the various components of the complex field, the power flux density of the field is
similarly indeterminate.
4.9
frequency band
continuous range of frequencies extending between two limits
4.10
induction field
d < λ/2π, where λ is the
predominant electric and/or magnetic field existing at a distance
wavelength and the physical dimensions of the source are much smaller than distance d
4.11
isotropic
having properties of equal values in all directions
4.12
polarization
orientation of the electric field vector of a radiated field

– 14 – 61000-4-3 © CEI:1995+A.1:1998

4.13
enceinte blindée
structure métallique étanche ou à écran, expressément conçue dans le but d'isoler l'intérieur

de l'environnement électromagnétique extérieur. Le but est d'empêcher les champs

électromagnétiques ambiants extérieurs de provoquer une dégradation des performances et

d'empêcher l'émission interne de provoquer des perturbations pour les activités extérieures

4.14
ligne TEM à plaques
ligne de transmission adaptée formée de deux plaques parallèles entre lesquelles une onde se

propage en mode électromagnétique transverse afin de produire un champ spécifié pour des
essais [VEI 161-04-31]
4.15
rayonnements parasites
toute émission électromagnétique indésirable émanant d'un dispositif électrique
4.16
balayage
vobulation continue ou incrémentale sur une gamme de fréquences
4.17
émetteur/récepteur
association dans un boîtier commun de matériel d'émission et de réception radio.
4.18
matériel porté par un corps humain
matériel prévu pour être utilisé lorsqu’il est porté par un corps humain. Cette définition inclut
les dispositifs portatifs qui sont tenus par les personnes pendant le fonctionnement (par
exemple les dispositifs de poche) ainsi que les prothèses électroniques et les implants
4.19
valeur efficace maximale
valeur efficace de courte durée la plus élevée d’un signal à fréquence radioélectrique modulé,
pendant une durée d’observation d’une période de modulation. La valeur efficace de courte
durée est évaluée sur une seule période de la porteuse. Par exemple, à la figure 1b), la tension
efficace maximale est la suivante:
V V ×
= / (2 2 ) = 1,8 volt
eff. maximale p-p
4.20
modulation à enveloppe non constante

type de modulation où l’amplitude de l’onde porteuse varie lentement dans le temps en
comparaison avec la période de la porteuse elle-même. Des exemples sont, notamment, la
modulation d’amplitude conventionnelle et l’AMRT
4.21
AMRT (accès multiple réparti dans le temps)
type de modulation à multiplexage temporel qui place plusieurs canaux de communication sur
la même onde porteuse à une fréquence allouée. A chaque canal est attribué un créneau de
temps durant lequel, si le canal est actif, l’information est transmise comme une impulsion de
puissance à fréquence radioélectrique. Si le canal n'est pas actif, aucune impulsion n'est
transmise, et donc l'enveloppe de la porteuse n'est pas constante. Pendant l’impulsion,
l’amplitude est constante et la porteuse à fréquence radioélectrique est modulée en fréquence
ou en phase
61000-4-3 © IEC:1995+A.1:1998 – 15 –

4.13
shielded enclosure
screened or solid metal housing designed expressly for the purpose of isolating the internal

from the external electromagnetic environment. The purpose is to prevent outside ambient

electromagnetic fields from causing performance degradation and to prevent emission from

causing interference to outside activities

4.14
stripline
terminated transmission line consisting of two parallel plates between which a wave is

propagated in the transverse electromagnetic mode to produce a specified field for testing
purposes [IEV 161-04-31]
4.15
spurious radiation
any undesired electromagnetic emission from an electrical device
4.16
sweep
continuous or incremental traverse over a range of frequencies
4.17
transceiver
combination of radio transmitting and receiving equipment in a common housing
4.18
human body-mounted equipment
equipment which is intended for use when attached to the human body. This definition includes
hand-held devices which are carried by people while in operation (e.g. pocket devices) as well
as electronic aid devices and implants
4.19
maximum RMS value
the highest short-term RMS value of a modulated RF signal during an observation time of one
modulation period. The short-term RMS is evaluated over a single carrier cycle. For example,
in figure 1b), the maximum RMS voltage is:
V = V / (2 × 2 ) = 1,8 volts
maximum RMS p-p
4.20
non-constant envelope modulation
RF modulation schemes where the amplitude of the carrier wave varies slowly in time
compared with the period of the carrier itself. Examples include conventional amplitude
modulation and TDMA
4.21
TDMA (time division multiple access)
a time multiplexing modulation scheme which places several communication channels on the
same carrier wave at an allocated frequency. Each channel is assigned a time slot during
which, if the channel is active, the information is transmitted as a pulse of RF power. If the
channel is not active no pulse is transmitted, thus the carrier envelope is not constant. During
the pulse, the amplitude is constant and the RF carrier is frequency- or phase-modulated

– 16 – 61000-4-3 © CEI:1995+A.1:1998

5 Niveaux d'essai
5.1 Niveaux d’essai relatifs aux cas généraux

La gamme préférentielle des niveaux d'essai est indiquée dans le tableau 1.

Gamme de fréquences: de 80 MHz à 1 000 MHz.

Tableau 1 – Niveaux d'essai
Niveau Valeur du champ d'essai
V/m
1 1
2 3
3 10
x Spécial
NOTE – x est un niveau à déterminer. Ce niveau peut être donné dans
la spécification de produit.
Le tableau 1 indique la valeur de champ du signal non modulé. Pour l'essai du matériel, ce
signal est modulé en amplitude à 80 % avec une onde sinusoïdale de 1 kHz pour simuler les
menaces réelles (voir figure 1). Pour la description de l'essai, se reporter à l'article 8.
NOTE 1 – Les comités de produit peuvent décider de choisir une fréquence frontière plus basse ou plus élevée que
80 MHz entre la CEI 61000-4-3 et la CEI 61000-4-6 (voir annexe H).
NOTE 2 – Les comités de produit peuvent adopter un autre type de modulation.
NOTE 3 –
La CEI 61000-4-6 définit également des méthodes d’essai d’immunité des matériels électriques et
électroniques aux rayonnements électromagnétiques. Elle couvre les fréquences en dessous de 80 MHz.
5.2 Niveaux d’essai relatifs à la protection contre les émissions aux fréquences
radioélectriques des radiotéléphones numériques
La gamme préférentielle des niveaux d’essai est indiquée au tableau 2 pour les gammes de
fréquences de 800 MHz à 960 MHz et de 1,4 GHz à 2,0 GHz.
Tableau 2 – Gammes de fréquences: 800 MHz à 960 MHz
et 1,4 GHz à 2,0 GHz
Niveau Valeur du champ d’essai
V/m
x Spécial
NOTE – x est un niveau à déterminer. Ce niveau peut être donné dans
la norme de produit.
La colonne relative à la valeur du champ d’essai donne les valeurs de la porteuse non
modulée. Pour l’essai du matériel, cette porteuse est modulée en amplitude à 80 % avec une
onde sinusoïdale de 1 kHz pour simuler les menaces réelles (voir figure 1). La description de
l’essai est donnée à l’article 8.

61000-4-3 © IEC:1995+A.1:1998 – 17 –

5 Test levels
5.1 Test levels related to general purposes

The preferential range of test levels is given in table 1.

Frequency range: 80 MHz to 1 000 MHz.

Table 1 – Test levels
Level Test field strength
V/m
1 1
2 3
3 10
x Special
NOTE – x is an open test level. This level may be given in the product
specification.
Table 1 gives details of the field strength of the unmodulated signal. For testing of
equipment, this signal is 80 % amplitude modulated with a 1 kHz sinewave to simulate actual
threats (see figure 1). Details of how the test is performed are given in clause 8.
NOTE 1 – Product committees may decide to choose a lower or higher transition frequency than 80 MHz between
IEC 61000-4-3 and IEC 61000-4-6 (see annex H).
NOTE 2 – Product committees may select alternative modulation schemes.
NOTE 3 – IEC 61000-4-6 also defines test methods for establishing the immunity of electrical and electronic
equipment against radiated electromagnetic energy. It covers frequencies below 80 MHz.
5.2 Test levels related to the protection against RF emissions from digital radio
telephones
The preferred range of test levels is given in table 2 for the frequency ranges from 800 MHz to
960 MHz and from 1,4 GHz to 2,0 GHz.
Table 2 – Frequency ranges: 800 MHz to 960 MHz
and 1,4 GHz to 2,0 GHz
Level Test field strength
V/m
x Special
NOTE – x is an open test level. This level may be given in the product
standard.
The test field strength column gives values of the unmodulated carrier signal. For testing of
equipment, this carrier signal is 80 % amplitude modulate
...


NORME CEI
INTERNATIONALE IEC
61000-4-3
INTERNATIONAL
Edition 1.2
STANDARD
2001-04
Edition 1:1995 consolidée par les amendements 1:1998 et 2:2000
Edition 1:1995 consolidated with amendments 1:1998 and 2:2000
PUBLICATION FONDAMENTALE EN CEM
BASIC EMC PUBLICATION
Compatibilité électromagnétique (CEM) –
Partie 4-3:
Techniques d’essai et de mesure –
Essai d’immunité aux champs électromagnétiques
rayonnés aux fréquences radioélectriques
Electromagnetic compatibility (EMC) –
Part 4-3:
Testing and measurement techniques –
Radiated, radio-frequency, electromagnetic field
immunity test
Numéro de référence
Reference number
CEI/IEC 61000-4-3:1995+A1:1998+A2:2000

Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and

base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61000-4-3
INTERNATIONAL
Edition 1.2
STANDARD
2001-04
Edition 1:1995 consolidée par les amendements 1:1998 et 2:2000
Edition 1:1995 consolidated with amendments 1:1998 and 2:2000
PUBLICATION FONDAMENTALE EN CEM
BASIC EMC PUBLICATION
Compatibilité électromagnétique (CEM) –
Partie 4-3:
Techniques d’essai et de mesure –
Essai d’immunité aux champs électromagnétiques
rayonnés aux fréquences radioélectriques
Electromagnetic compatibility (EMC) –
Part 4-3:
Testing and measurement techniques –
Radiated, radio-frequency, electromagnetic field
immunity test
 IEC 2001 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
W
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 61000-4-3  CEI:1995+A1:1998
2 –
+A2:2000
SOMMAIRE
Pages
AVANT-PROPOS . 6

INTRODUCTION . 10

Articles
1 Domaine d'application et objet. 12
2 Références normatives. 12
3 Généralités . 14
4 Définitions. 14
5 Niveaux d'essai .20
6 Matériel d'essai . 22
7 Montage d'essai . 28
8 Procédures d'essai. 30
9 Evaluation des résultats d’essai. 34
10 Rapport d’essai . 34
Annexe A (informative) Justification du choix de la modulation pour les essais relatifs
à la protection contre les émissions aux fréquences radioélectriques des
radiotéléphones numériques . 48
Annexe B (informative) Antennes émettrices. 58
Annexe C (informative) Utilisation des chambres anéchoïques. 60
Annexe D (informative) Autres méthodes d'essais –
Cellules TEM et lignes TEM à plaques . 62
Annexe E (informative) Autres installations d'essai . 64
Annexe F (informative) Informations destinées aux comités de produits
sur le choix des niveaux d’essai. 66
Annexe G (informative) Mesures spéciales pour les transmetteurs fixes. 72
Annexe H (informative) Choix des méthodes d'essai . 72
Annexe I (informative) Description de l’environnement . 74

Figure 1 – Définition du niveau d'essai et des formes d'onde apparaissant
à la sortie du générateur de signaux . 36
Figure 2 – Exemple d'installation d'essai. 38
Figure 3 – Etalonnage du champ. 40
Figure 4 – Etalonnage du champ, dimensions de la zone uniforme . 42
Figure 5 – Exemple de montage d'essai pour un matériel posé au sol . 44
Figure 6 – Exemple de montage d'essai pour un matériel de table. 46

61000-4-3  IEC:1995+A1:1998 – 3 –

+A2:2000
CONTENTS
Page
FOREWORD . 7

INTRODUCTION . 11

Clause
1 Scope and object . 13
2 Normative references . 13
3 General. 15
4 Definitions. 15
5 Test levels . 21
6 Test equipment . 23
7 Test set-up. 29
8 Test procedures . 31
9 Evaluation of test results . 35
10 Test report . 35
Annex A (informative) Rationale for the choice of modulation for tests related
to the protection against RF emissions from digital radio telephones . 49
Annex B (informative) Field generating antennas . 59
Annex C (informative) Use of anechoic chambers . 61
Annex D (informative) Other test methods – TEM cells and striplines . 63
Annex E (informative) Other test facilities . 65
Annex F (informative) Guidance for product committees on the selection of test levels. 67
Annex G (informative) Special measures for fixed transmitters. 73
Annex H (informative) Selection of test methods . 73
Annex I (informative) Description of the environment . 75
Figure 1 – Definition of the test level and the waveshapes occurring
at the output of the signal generator. 37

Figure 2 – Example of suitable test facility . 39
Figure 3 – Calibration of field . 41
Figure 4 – Calibration of field, dimensions of the uniform area. 43
Figure 5 – Example of test set-up for floor-standing equipment . 45
Figure 6 – Example of test set-up for table-top equipment. 47

– 61000-4-3  CEI:1995+A1:1998
4 –
+A2:2000
Pages
Tableau 1 – Niveaux d'essai . 20

Tableau 2 – Gammes de fréquences: 800 MHz à 960 MHz et 1,4 GHz à 2,0 GHz . 20

Tableau A.1 − Comparaison des méthodes de modulation. 50

Tableau A.2 − Niveaux de brouillage relatifs (note 1). 52

Tableau A.3 − Niveaux d’immunité relatifs (note 1). 54

Tableau F.1 − Exemples de niveaux d’essai, de distances de protection associées

et suggestions de critères d’aptitude à la fonction . 68
Tableau I.1 – Unités mobiles et portables. 76
Tableau I.2 – Stations de base. 76

61000-4-3  IEC:1995+A1:1998 – 5 –

+A2:2000
Page
Table 1 – Test levels . 21

Table 2 – Frequency ranges: 800 MHz to 960 MHz and 1,4 GHz to 2,0 GHz . 21


Table A.1 Comparison of modulation methods . 51


Table A.2 Relative interference levels (note 1) . 53

Table A.3 − Relative immunity levels (note 1). 55

Table F.1 – Examples of test levels, associated protection distances

and suggested performance criteria . 69
Table I.1 – Mobile and portable units . 77
Table I.2 – Base stations . 77

– 61000-4-3  CEI:1995+A1:1998
6 –
+A2:2000
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

_________
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –

Partie 4-3: Techniques d'essai et de mesure –

Essai d'immunité aux champs électromagnétiques rayonnés

aux fréquences radioélectriques

AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61000-4-3 a été établie par le sous-comité 65A: Aspects systèmes,
du comité d'études 65 de la CEI: Mesure et commande dans les processus industriels.
Elle constitue la section 3 de la partie 4 de la norme CEI 61000 et remplace la première édition
de la CEI 60801-3, parue en 1984. Elle a le statut de publication fondamentale en CEM en

accord avec le Guide 107 de la CEI.
La présente version consolidée de la CEI 61000-4-3 est issue de la première édition (1995), de
son amendement 1 (1998) [documents 77B/234+235/FDIS et 77B/238+239/RVD] et de son
amendement 2 (2000) [documents 77B/291/FDIS et 77B/298/RVD].
Elle porte le numéro d'édition 1.2.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1 et l'amendement 2.
Les annexes A à I sont données uniquement à titre d'information.

61000-4-3  IEC:1995+A1:1998 – 7 –

+A2:2000
INTERNATIONAL ELECTROTECHNICAL COMMISSION

_________
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –

Radiated, radio-frequency, electromagnetic field immunity test

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-4-3 has been prepared by subcommittee 65A: System
aspects, of IEC technical committee 65: Industrial-process measurement and control.
It forms section 3 of part 4 of IEC 61000 and replaces the first edition of IEC 60801-3 issued
in 1984. It has the status of a basic EMC publication in accordance with IEC Guide 107.

This consolidated version of IEC 61000-4-3 is based on the first edition (1995), its amendment 1
(1998) [documents 77B/234+235/FDIS and 77B/238+239/RVD] and amendment 2 (2000)
[documents 77B/291/FDIS and 77B/298/RVD].
It bears the edition number 1.2.
A vertical line in the margin shows where the base publication has been modified by
amendment 1 and amendment 2.
Annexes A to I are for information only.

– 61000-4-3  CEI:1995+A1:1998
8 –
+A2:2000
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera

pas modifié avant 2002. A cette date, la publication sera

reconduite;
supprimée;
remplacée par une édition révisée, ou

amendée.
61000-4-3  IEC:1995+A1:1998 – 9 –

+A2:2000
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2002. At this date, the publication will be

reconfirmed;
withdrawn;
replaced by a revised edition, or

amended.
– 61000-4-3  CEI:1995+A1:1998
10 –
+A2:2000
INTRODUCTION
La présente norme fait partie de la série des normes 61000 de la CEI, selon la répartition

suivante:
Partie 1: Généralités
Considérations générales (introduction, principes fondamentaux)

Définitions, terminologie
Partie 2: Environnement
Description de l'environnement
Classification de l'environnement
Niveaux de compatibilité
Partie 3: Limites
Limites d'émission
Limites d'immunité (dans la mesure où elles ne relèvent pas des comités de produit)
Partie 4: Techniques d'essai et de mesure
Techniques de mesure
Techniques d'essai
Partie 5: Guide d'installation et d'atténuation
Guide d'installation
Méthodes et dispositifs d'atténuation
Partie 9: Divers
Chaque partie est à son tour subdivisée en sections qui seront publiées soit comme Normes
internationales soit comme rapports techniques.
La présente section constitue une norme internationale qui traite des prescriptions en matière
d'immunité et des procédures d'essai qui s'appliquent aux champs électromagnétiques
rayonnés aux fréquences radioélectriques.

61000-4-3  IEC:1995+A1:1998 – 11 –

+A2:2000
INTRODUCTION
This standard is part of the IEC 61000 series, according to the following structure:

Part 1: General
General considerations (introduction, fundamental principles)

Definitions, terminology
Part 2: Environment
Description of the environment

Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of the product committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 9: Miscellaneous
Each part is further subdivided into sections which are to be published either as International
Standards or as technical reports.
This section is an International Standard which gives immunity requirements and test
procedures related to radiated, radio-frequency, electromagnetic fields.

– 61000-4-3  CEI:1995+A1:1998
12 –
+A2:2000
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –

Partie 4-3: Techniques d'essai et de mesure –

Essai d'immunité aux champs électromagnétiques rayonnés

aux fréquences radioélectriques

1 Domaine d'application et objet
La présente section de la CEI 61000-4 traite de l'immunité des matériels électriques et
électroniques à l'énergie électromagnétique rayonnée. Elle définit les niveaux d'essai et les
procédures d'essai nécessaires.
Cette section a pour objet d'établir une référence commune d'évaluation des performances des
matériels électriques et électroniques soumis à des champs électromagnétiques aux
fréquences radioélectriques.
La présente section traite des essais d’immunité relatifs aux cas généraux. Des considérations
particulières sont consacrées à la protection contre les émissions aux fréquences radio-
électriques des radiotéléphones numériques.
NOTE Cette section définit des méthodes d'essai pour mesurer l'incidence des rayonnements électromagnétiques
sur le matériel concerné. La simulation et les mesures des rayonnements électromagnétiques ne sont pas
suffisamment exactes pour déterminer quantitativement les effets. Les méthodes d'essai définies ont été
principalement mises au point pour obtenir une bonne reproductibilité des résultats sur différentes installations
d'essai en vue d'une analyse qualitative des effets.
Cette section ne vise pas à spécifier les essais devant s'appliquer à des appareils ou systèmes
particuliers. Le but principal est de donner une référence de base d'ordre général à tous les
comités de produits CEI concernés. Les comités de produits (ou les utilisateurs et fabricants
de matériel) restent responsables du choix approprié des essais et du niveau de sévérité à
appliquer à leur matériel.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 61000.
Au moment de la publication, les éditions indiquées étaient en vigueur. Tout document normatif
est sujet à révision, et les parties prenantes aux accords fondés sur la présente partie de la
CEI 61000 sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes
des documents normatifs indiqués ci-après. Les membres de la CEI et de l'ISO possèdent le
registre des Normes internationales en vigueur.
CEI 60050(161):1990, Vocabulaire Electrotechnique International (VEI) – Chapitre 161:
Compatibilité électromagnétique
CEI 61000-4-6:1996, Compatibilité électromagnétique (CEM) – Partie 4: Techniques d'essai
et de mesure – Section 6: Essai d'immunité aux perturbations conduites, induites par les
champs électromagnétiques aux fréquences radioélectriques

61000-4-3  IEC:1995+A1:1998 – 13 –

+A2:2000
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –

Radiated, radio-frequency, electromagnetic field immunity test

1 Scope and object
This section of IEC 61000-4 is applicable to the immunity of electrical and electronic equipment
to radiated electromagnetic energy. It establishes test levels and the required test procedures.
The object of this section is to establish a common reference for evaluating the performance of
electrical and electronic equipment when subjected to radio-frequency electromagnetic fields.
This section deals with immunity tests related to general purposes. Particular considerations
are devoted to the protection against radiofrequency emissions from digital radio telephones.
NOTE Test methods are defined in this section for measuring the effect that electromagnetic radiation has on the
equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for
quantitative determination of effects. The test methods defined are structured for the primary objective of
establishing adequate repeatability of results at various test facilities for qualitative analysis of effects.
This section does not intend to specify the tests to be applied to particular apparatus or
systems. Its main aim is to give a general basic reference to all concerned product committees
of the IEC. The product committees (or users and manufacturers of equipment) remain
responsible for the appropriate choice of the tests and the severity level to be applied to their
equipment.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 61000. At the time of publication, the editions indicated
were valid. All normative documents are subject to revision, and parties to agreements based
on this part of IEC 61000 are encouraged to investigate the possibility of applying the most
recent editions of the normative documents indicated below. Members of IEC and ISO maintain
registers of currently valid International Standards.
IEC 60050(161):1990, International Electrotechnical Vocabulary (IEV) – Chapter 161:

Electromagnetic compatibility
IEC 61000-4-6:1996, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 6: Immunity to conducted disturbances induced by radio-frequency fields

– 61000-4-3  CEI:1995+A1:1998
14 –
+A2:2000
3 Généralités
La plupart des matériels électroniques sont, dans une certaine mesure, perturbés par les

rayonnements électromagnétiques. Ces rayonnements proviennent souvent de petits

émetteurs/récepteurs radio portatifs utilisés par le personnel d'exploitation, de maintenance et

de sécurité, des émetteurs fixes de radio et télévision, des émetteurs radio utilisés à bord des

véhicules et de diverses sources électromagnétiques industrielles.

Ces dernières années, il a été constaté une augmentation significative de l’utilisation de

radiotéléphones et autres radiotransmetteurs fonctionnant à des fréquences comprises entre

0,8 GHz et 3 GHz. Beaucoup de ces services utilisent des méthodes de modulation avec une
enveloppe non constante (par exemple AMRT).
En dehors de cette énergie électromagnétique rayonnée de façon délibérée, il existe
également des rayonnements parasites provoqués par des appareils de soudure, des
thyristors, des éclairages fluorescents, des commutateurs de charges inductives, etc. Pour la
plus grande part, ces perturbations se manifestent sous forme de perturbations électriques
conduites et, en tant que telles, sont traitées dans d'autres parties de la présente norme. Les
méthodes utilisées pour prévenir les effets des champs électromagnétiques réduisent aussi
normalement les effets provoqués par ces sources.
L'environnement électromagnétique est déterminé par la valeur du champ électromagnétique
(la valeur du champ est exprimée en volts par mètre). Les structures environnantes ou la
proximité d'autres matériels déformant et/ou réfléchissant les ondes électromagnétiques
rendent la mesure du champ difficile sans l'utilisation d'instruments sophistiqués et son calcul
n'est pas aisé avec les équations et les formules classiques.
4 Définitions
Pour les besoins de la présente section de la CEI 61000-4, les définitions suivantes et celles
de la CEI 60050(161) s'appliquent.
4.1
modulation d'amplitude
opération par laquelle on fait varier l'amplitude d'une onde porteuse suivant une loi spécifiée
4.2
chambre anéchoïque
enceinte blindée revêtue d'un matériau absorbant les ondes radioélectriques afin de réduire les
réflexions provenant des surfaces internes

4.2.1
chambre totalement anéchoïque
enceinte blindée dont les surfaces internes sont totalement revêtues d'un matériau absorbant
4.2.2
chambre semi-anéchoïque
enceinte blindée dont toutes les surfaces internes sont revêtues d'un matériau absorbant à
l'exception du sol, qui doit être réfléchissant (plan de sol)
4.2.3
chambre semi-anéchoïque modifiée
chambre semi-anéchoïque dans laquelle des absorbants supplémentaires sont disposés sur le
plan de sol
61000-4-3  IEC:1995+A1:1998 – 15 –

+A2:2000
3 General
Most electronic equipment is, in some manner, affected by electromagnetic radiation. This

radiation is frequently generated by such sources as the small hand-held radio transceivers

that are used by operating, maintenance and security personnel, fixed-station radio and

television transmitters, vehicle radio transmitters, and various industrial electromagnetic

sources.
In recent years there has been a significant increase in the use of radio telephones and other

radio transmitters operating at frequencies between 0,8 GHz and 3 GHz. Many of these
services use modulation techniques with a non-constant envelope (e.g. TDMA).
In addition to electromagnetic energy deliberately generated, there is also spurious radiation
caused by devices such as welders, thyristors, fluorescent lights, switches operating inductive
loads, etc. For the most part, this interference manifests itself as conducted electrical inter-
ference and, as such, is dealt with in other parts of this standard. Methods employed to prevent
effects from electromagnetic fields will normally also reduce the effects from these sources.
The electromagnetic environment is determined by the strength of the electromagnetic field
(field strength in volts per metre). The field strength is not easily measured without
sophisticated instrumentation nor is it easily calculated by classical equations and formulae
because of the effect of surrounding structures or the proximity of other equipment that will
distort and/or reflect the electromagnetic waves.
4 Definitions
For the purposes of this section of IEC 61000-4, the following definitions, together with those in
IEC 60050(161) apply.
4.1
amplitude modulation
process by which the amplitude of a carrier wave is varied following a specified law
4.2
anechoic chamber
shielded enclosure which is lined with radio-frequency absorbers to reduce reflections from the
internal surfaces
4.2.1
fully anechoic chamber
shielded enclosure whose internal surfaces are totally lined with anechoic material
4.2
semi-anechoic chamber
shielded enclosure where all internal surfaces are covered with anechoic material with the
exception of the floor, which shall be reflective (ground plane)
4.2.3
modified semi-anechoic chamber
semi-anechoic chamber which has additional absorbers installed on the ground plane

– 61000-4-3  CEI:1995+A1:1998
16 –
+A2:2000
4.3
antenne
transducteur servant soit à l'émission de puissance aux fréquences radioélectriques dans

l'espace à partir d'une source de signaux, soit à intercepter l'arrivée d'un champ électro-
magnétique en le convertissant en un signal électrique

4.4
symétriseur
dispositif transformant une tension symétrique par rapport à la masse en une tension

asymétrique ou inversement. [VEI 161-04-34]

4.5
ondes entretenues
ondes électromagnétiques dont les oscillations successives sont identiques en régime établi et
qui peuvent être interrompues ou modulées pour transmettre des informations
4.6
onde électromagnétique
énergie rayonnante créée par l'oscillation d'une charge électrique caractérisée par l'oscillation
des champs électrique et magnétique
4.7
champ lointain
région dans laquelle la puissance surfacique émise par une antenne obéit approximativement à
la loi de l'inverse du carré de la distance.
Pour un dipôle, cela correspond à des distances supérieures à λ/2π où λ désigne la longueur
d'onde du rayonnement
4.8
valeur du champ
le terme «valeur du champ» n'est utilisé que pour les mesures effectuées en champ lointain.
Ces mesures peuvent concerner soit la composante électrique, soit la composante magnétique
du champ et peuvent être exprimées en V/m, A/m ou W/m , chacune de ces unités pouvant
être convertie dans les autres unités
NOTE Pour les mesures effectuées en champ proche, on utilisera le terme de «champ électrique» ou de «champ
magnétique» suivant que le champ résultant, électrique ou magnétique, est mesuré. Dans cette région du champ, la
relation entre les valeurs des champs électrique et magnétique et la distance est complexe et difficile à prévoir
puisqu'elle dépend des configurations spécifiques. Dans la mesure où il n'est généralement pas possible de
déterminer la relation de phase spatio-temporelle des différentes composantes du champ complexe, la puissance
surfacique est, de la même manière, indéterminée.
4.9
bande de fréquences
gamme continue de fréquences située entre deux limites
4.10
champ d’induction
champ électrique et/ou magnétique prédominant à une distance d < λ/2π, où λ désigne la
longueur d’onde, et où les dimensions physiques de la source sont nettement plus petites que
la distance d
4.11
isotrope
ayant des propriétés d'égale valeur dans toutes les directions
4.12
polarisation
orientation du vecteur de champ électrique d'un champ rayonné

61000-4-3  IEC:1995+A1:1998 – 17 –

+A2:2000
4.3
antenna
transducer which either emits radio-frequency power into space from a signal source or

intercepts an arriving electromagnetic field, converting it into an electrical signal

4.4
balun
device for transforming an unbalanced voltage to a balanced voltage or vice versa [IEV 161-04-34]

4.5
continuous waves (CW)
electromagnetic waves, the successive oscillations of which are identical under steady-state
conditions, which can be interrupted or modulated to convey information
4.6
electromagnetic (EM) wave
radiant energy produced by the oscillation of an electric charge characterized by oscillation of
the electric and magnetic fields
4.7
far field
region where the power flux density from an antenna approximately obeys an inverse square
law of the distance.
For a dipole this corresponds to distances greater than λ/2π, where λ is the wavelength of the
radiation
4.8
field strength
the term "field strength" is applied only to measurements made in the far field. The
measurement may be of either the electric or the magnetic component of the field and may be
expressed as V/m, A/m or W/m ; any one of these may be converted into the others
NOTE For measurements made in the near field, the term "electric field strength" or "magnetic field strength" is
used according to whether the resultant electric or magnetic field, respectively, is measured. In this field region, the
relationship between the electric and magnetic field strength and distance is complex and difficult to predict, being
dependent on the specific configuration involved. Inasmuch as it is not generally feasible to determine the time and
space phase relationship of the various components of the complex field, the power flux density of the field is
similarly indeterminate.
4.9
frequency band
continuous range of frequencies extending between two limits
4.10
induction field
d < λ/2π, where λ is the
predominant electric and/or magnetic field existing at a distance
wavelength and the physical dimensions of the source are much smaller than distance d
4.11
isotropic
having properties of equal values in all directions
4.12
polarization
orientation of the electric field vector of a radiated field

– 61000-4-3  CEI:1995+A1:1998
18 –
+A2:2000
4.13
enceinte blindée
structure métallique étanche ou à écran, expressément conçue dans le but d'isoler l'intérieur

de l'environnement électromagnétique extérieur. Le but est d'empêcher les champs
électromagnétiques ambiants extérieurs de provoquer une dégradation des performances et
d'empêcher l'émission interne de provoquer des perturbations pour les activités extérieures

4.14
ligne TEM à plaques
ligne de transmission adaptée formée de deux plaques parallèles entre lesquelles une onde se

propage en mode électromagnétique transverse afin de produire un champ spécifié pour des
essais [VEI 161-04-31]
4.15
rayonnements parasites
toute émission électromagnétique indésirable émanant d'un dispositif électrique
4.16
balayage
vobulation continue ou incrémentale sur une gamme de fréquences
4.17
émetteur/récepteur
association dans un boîtier commun de matériel d'émission et de réception radio.
4.18
matériel porté par un corps humain
matériel prévu pour être utilisé lorsqu’il est porté par un corps humain. Cette définition inclut
les dispositifs portatifs qui sont tenus par les personnes pendant le fonctionnement (par
exemple les dispositifs de poche) ainsi que les prothèses électroniques et les implants
4.19
valeur efficace maximale
valeur efficace de courte durée la plus élevée d’un signal à fréquence radioélectrique modulé,
pendant une durée d’observation d’une période de modulation. La valeur efficace de courte
durée est évaluée sur une seule période de la porteuse. Par exemple, à la figure 1b), la tension
efficace maximale est la suivante:
V = V / (2 × 2 ) = 1,8 volt
eff. maximale p-p
4.20
modulation à enveloppe non constante

type de modulation où l’amplitude de l’onde porteuse varie lentement dans le temps en
comparaison avec la période de la porteuse elle-même. Des exemples sont, notamment, la
modulation d’amplitude conventionnelle et l’AMRT
4.21
AMRT (accès multiple réparti dans le temps)
type de modulation à multiplexage temporel qui place plusieurs canaux de communication sur
la même onde porteuse à une fréquence allouée. A chaque canal est attribué un créneau de
temps durant lequel, si le canal est actif, l’information est transmise comme une impulsion de
puissance à fréquence radioélectrique. Si le canal n'est pas actif, aucune impulsion n'est
transmise, et donc l'enveloppe de la porteuse n'est pas constante. Pendant l’impulsion,
l’amplitude est constante et la porteuse à fréquence radioélectrique est modulée en fréquence
ou en phase
61000-4-3  IEC:1995+A1:1998 – 19 –

+A2:2000
4.13
shielded enclosure
screened or solid metal housing designed expressly for the purpose of isolating the internal

from the external electromagnetic environment. The purpose is to prevent outside ambient

electromagnetic fields from causing performance degradation and to prevent emission from
causing interference to outside activities

4.14
stripline
terminated transmission line consisting of two parallel plates between which a wave is
propagated in the transverse electromagnetic mode to produce a specified field for testing
purposes [IEV 161-04-31]
4.15
spurious radiation
any undesired electromagnetic emission from an electrical device
4.16
sweep
continuous or incremental traverse over a range of frequencies
4.17
transceiver
combination of radio transmitting and receiving equipment in a common housing
4.18
human body-mounted equipment
equipment which is intended for use when attached to the human body. This definition includes
hand-held devices which are carried by people while in operation (e.g. pocket devices) as well
as electronic aid devices and implants
4.19
maximum RMS value
the highest short-term RMS v
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.