EN 61000-4-12:2017
(Main)Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
NEW!IEC 61000-4-12:2017 is available as IEC 61000-4-12:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a mathematical modelling of ring wave waveform; b) new Annex B on selection of generators and test levels; c) new Annex C on explanatory notes; d) new Annex D on measurement uncertainty; e) addition of high speed CDN; f) addition of a calibration procedure for CDN.
Elektromagnetische Verträglichkeit (EMV) - Teil 4-12: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen gedämpfte Sinusschwingungen (Ring wave)
Compatibilité électromagnétique (CEM) - Partie 4-12: Techniques d'essai et de mesure - Essai d'immunité à l’onde sinusoïdale fortement amortie
NEW!IEC 61000-4-12:2017 est disponible sous forme de IEC 61000-4-12:2017 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.L’IEC 61000-4-12:2017 traite des méthodes d'essai des matériels électriques et électroniques dans leurs conditions d'exploitation et des exigences d'immunité aux ondes sinusoïdales fortement amorties se manifestant sur les alimentations basse tension ainsi que sur les lignes de commande et de signal raccordées aux réseaux publics ou privés. Le présent document a pour objet d'établir une référence commune dans le but d'évaluer l’immunité des matériels électriques et électroniques soumis à des ondes sinusoïdales fortement amorties. La méthode d’essai documentée dans la présente partie de l’IEC 61000 décrit une méthode cohérente en vue d'évaluer l'immunité d'un matériel ou d'un système vis‑à-vis d'un phénomène défini. Elle a le statut de publication fondamentale en CEM en accord avec le Guide 107 de l’IEC. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: a) ajout d’une modélisation mathématique de forme d’onde sinusoïdale fortement amortie; b) ajout d’une nouvelle Annexe B relative à la sélection des générateurs et des niveaux d’essai; c) ajout d’une nouvelle Annexe C relative aux notes explicatives; d) ajout d’une nouvelle Annexe D relative à l’incertitude de mesure; e) ajout d’un RCD à grande vitesse; f) ajout d’une procédure d’étalonnage pour le RCD.
Elektromagnetna združljivost (EMC) - 4-12. del: Preskusne in merilne tehnike - Preskus odpornosti proti zadušenemu nihajnemu valu
Ta del standarda IEC 61000 se nanaša na zahteve glede odpornosti in preskusne metode za električno in elektronsko opremo v pogojih obratovanja v povezavi z zadušenimi nihajnimi valovi, ki nastajajo v nizkonapetostnih močnostnih, krmilnih in signalnih vodih, napajanih prek javnih in nejavnih omrežij.
Namen tega dokumenta je določiti skupno referenco za vrednotenje odpornosti električne in elektronske opreme proti zadušenim nihajnim valovom. Preskusna metoda, dokumentirana v tem delu standarda IEC 61000, opisuje skladno metodo za oceno odpornosti opreme ali sistema proti opredeljenemu pojavu.
OPOMBA: To je osnovna objava o elektromagnetni združljivosti, ki jo uporabljajo tehnični odbori v okviru Mednarodne elektrotehniške komisije (IEC), kot je opisano v vodilu 107 Mednarodne elektrotehniške komisije.
Poleg tega je v vodilu 107 navedeno, da so tehnični odbori v okviru Mednarodne elektrotehniške komisije odgovorni za določitev morebitne uporabe tega standarda s preskusom odpornosti, v primeru uporabe pa so odgovorni za določitev ustreznih preskusnih ravni in meril učinkovitosti. Odbor TC 77 in njegovi pododbori so pripravljeni za sodelovanje s tehničnimi odbori pri vrednotenju posameznih preskusov odpornosti in preskusnih ravni odpornosti za ustrezne proizvode.
Ta dokument določa:
– preskusno napetost in valovno obliko toka;
– obseg preskusnih ravni;
– opremo za preskušanje;
– postavitev za preskušanje;
– preskusne postopke.
General Information
Relations
Overview
EN 61000-4-12:2017 (IEC 61000-4-12:2017) defines a standardized ring wave immunity test used in electromagnetic compatibility (EMC) evaluations. It specifies immunity requirements and a consistent test method to assess how electrical and electronic equipment, under normal operating conditions, tolerate ring waves on low-voltage power, control and signal lines supplied by public and non‑public networks. The edition is available as an RLV (Redline Version) showing changes from the previous edition and has status as a basic EMC publication under IEC Guide 107.
Key topics and technical requirements
- Phenomenon and waveform: description and mathematical modelling of the damped sinusoidal ring wave (open-circuit voltage and short-circuit current).
- Test levels and selection: defined test levels and guidance (Table 1 and Annex B) for different installation classes and port types.
- Test instrumentation:
- Ring wave generator: circuit topology, impedance values and performance characteristics.
- Coupling/decoupling networks (CDNs): designs for AC/DC power ports and for interconnection lines (unshielded/ shielded, symmetrical/unsymmetrical).
- High‑speed CDN: new inclusion for high-frequency interconnection lines.
- Calibration and verification:
- Calibration procedures for the ring wave generator and for CDNs (explicit calibration process added).
- Measurement uncertainty analysis (new Annex D) with contributors and example uncertainty budgets.
- Test setup and execution: EUT connections, protective earth requirements, laboratory reference conditions, repetition rate and phase angle considerations.
- Evaluation and reporting: performance criteria, test report content and pass/fail assessment procedures.
- Informative annexes: Annex B (generator/test level selection), Annex C (explanatory notes), Annex D (measurement uncertainty).
Practical applications
- Validates immunity of consumer, industrial and medical equipment against ring waves caused by switching, faults or transients on low-voltage networks.
- Used to qualify equipment connected to power, control and signal lines where damped sinusoidal disturbances are likely.
- Ensures robust product behavior in real-world installations (public grid, generator-fed systems, local networks).
Who should use this standard
- EMC test laboratories and certification bodies performing immunity testing.
- Product designers, compliance engineers and test engineers for electrical/electronic equipment.
- Utilities and system integrators concerned with equipment resilience on power and signal lines.
Related standards and keywords
Relevant references include other IEC/EN EMC standards (e.g., IEC 61000-4-5, IEC 61000-4-18) and environmental/testing guides (IEC 60068 series).
Keywords: EN 61000-4-12:2017, IEC 61000-4-12, ring wave immunity test, EMC testing, coupling/decoupling network (CDN), ring wave generator, CDN calibration, measurement uncertainty.
Frequently Asked Questions
EN 61000-4-12:2017 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test". This standard covers: NEW!IEC 61000-4-12:2017 is available as IEC 61000-4-12:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a mathematical modelling of ring wave waveform; b) new Annex B on selection of generators and test levels; c) new Annex C on explanatory notes; d) new Annex D on measurement uncertainty; e) addition of high speed CDN; f) addition of a calibration procedure for CDN.
NEW!IEC 61000-4-12:2017 is available as IEC 61000-4-12:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a mathematical modelling of ring wave waveform; b) new Annex B on selection of generators and test levels; c) new Annex C on explanatory notes; d) new Annex D on measurement uncertainty; e) addition of high speed CDN; f) addition of a calibration procedure for CDN.
EN 61000-4-12:2017 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61000-4-12:2017 has the following relationships with other standards: It is inter standard links to EN 61000-4-12:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61000-4-12:2017 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 61000-4-12:2017 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2018
1DGRPHãþD
SIST EN 61000-4-12:2007
Elektromagnetna združljivost (EMC) - 4-12. del: Preskusne in merilne tehnike -
Preskus odpornosti proti zadušenemu nihajnemu valu
Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques -
Ring wave immunity test
Elektromagnetische Verträglichkeit (EMV) - Teil 4-12: Prüf- und Messverfahren -
Störfestigkeit gegen gedämpfte Sinusschwingungen (Ringwave)
Compatibilité électromagnétique (CEM) - Partie 4-12: Techniques d'essai et de mesure -
Essai d'immunité à l'onde sinusoïdale amortie
Ta slovenski standard je istoveten z: EN 61000-4-12:2017
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 61000-4-12
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2017
ICS 33.100.20 Supersedes EN 61000-4-12:2006
English Version
Electromagnetic compatibility (EMC) - Part 4-12: Testing and
measurement techniques - Ring wave immunity test
(IEC 61000-4-12:2017)
Compatibilité électromagnétique (CEM) - Elektromagnetische Verträglichkeit (EMV) -
Partie 4-12: Techniques d'essai et de mesure - Essai Teil 4-12: Prüf- und Messverfahren - Prüfung der
d'immunité à l'onde sinusoïdale fortement amortie Störfestigkeit gegen gedämpfte Sinusschwingungen (Ring
(IEC 61000-4-12:2017) wave)
(IEC 61000-4-12:2017)
This European Standard was approved by CENELEC on 2017-08-22. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61000-4-12:2017 E
European foreword
The text of document 77B/764/CDV, future edition 3 of IEC 61000-4-12, prepared by SC 77B "High
frequency phenomena" of IEC/TC 77 "Electromagnetic compatibility" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 61000-4-12:2017.
The following dates are fixed:
(dop) 2018-05-22
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2020-08-22
standards conflicting with the
document have to be withdrawn
This document supersedes EN 61000-4-12:2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 61000-4-12:2017 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60068-1 NOTE Harmonized as EN 60068-1.
IEC 61000-4-5 NOTE Harmonized as EN 61000-4-5.
IEC 61000-4-18 NOTE Harmonized as EN 61000-4-18.
IEC 61010-1 NOTE Harmonized as EN 61010-1.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050 Series International Electrotechnical Vocabulary - -
(IEV)
IEC 61000-4-12 ®
Edition 3.0 2017-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
Electromagnetic compatibility (EMC) –
Part 4-12: Testing and measurement techniques – Ring wave immunity test
Compatibilité électromagnétique (CEM) –
Partie 4-12: Techniques d'essai et de mesure – Essai d'immunité à l’onde
sinusoïdale fortement amortie
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.100.20 ISBN 978-2-8322-4556-9
– 2 – IEC 61000-4-12:2017 © IEC 2017
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms, definitions and abbreviated terms . 8
3.1 Terms and definitions . 8
3.2 Abbreviated terms . 10
4 General . 10
4.1 Description of the phenomenon . 10
4.2 Relevant parameters . 12
4.2.1 Repetition rate . 12
4.2.2 Phase angle . 12
5 Test levels . 13
6 Test instrumentation . 13
6.1 Ring wave generator . 13
6.1.1 Ring wave generator circuit . 13
6.1.2 Impedance values . 14
6.1.3 Performance characteristics of the ring wave generator . 14
6.1.4 Calibration of the ring wave generator . 15
6.2 Coupling/decoupling networks . 15
6.2.1 General . 15
6.2.2 Coupling/decoupling networks for AC/DC power port rated up to 63 A
per line . 16
6.2.3 Coupling/decoupling networks for interconnection lines . 19
6.3 Calibration of coupling/decoupling networks . 22
6.3.1 General . 22
6.3.2 Calibration of CDNs for AC/DC power port rated up to 63 A per line . 22
6.3.3 Calibration of CDNs for interconnection lines . 23
7 Test setup . 26
7.1 Test equipment . 26
7.2 Verification of the test instrumentation . 27
7.3 Test setup for ring waves applied to EUT power ports . 27
7.4 Test setup for ring waves applied to unshielded unsymmetrical
interconnection lines . 28
7.5 Test setup for ring waves applied to unshielded symmetrical interconnection
lines . 28
7.6 Test setup for ring waves applied to shielded lines . 28
7.7 Protective earth connection . 29
8 Test procedure . 30
8.1 General . 30
8.2 Laboratory reference conditions . 30
8.2.1 Climatic conditions . 30
8.2.2 Electromagnetic conditions . 30
8.3 Execution of the test . 30
9 Evaluation of test results . 31
IEC 61000-4-12:2017 © IEC 2017 – 3 –
10 Test report . 32
Annex A (informative) Information on electromagnetic environments, installation
classes and test levels . 33
Annex B (informative) Selection of generators and test levels . 35
B.1 General . 35
B.2 The classification of environments . 35
B.3 The definition of port types. 35
B.4 Selection of the test levels . 36
Annex C (informative) Explanatory notes . 38
C.1 Different source impedance . 38
C.2 Application of the tests . 38
C.2.1 Equipment level immunity . 38
C.2.2 System level immunity . 38
Annex D (informative) Measurement uncertainty (MU) considerations . 39
D.1 General . 39
D.2 Legend for ring wave parameters . 39
D.3 Uncertainty contributors to the ring wave measurement uncertainty . 40
D.4 Uncertainty of the generator output voltage and current measurement . 40
D.4.1 General . 40
D.4.2 Rise time of the ring wave . 40
D.4.3 Peak of the ring wave . 42
D.4.4 Further MU contributions to time measurements . 43
D.4.5 Rise time of the step response and bandwidth of the frequency
response of the measuring system . 43
D.4.6 Impulse peak and width distortion due to the limited bandwidth of the
measuring system . 44
D.5 Application of uncertainties in the ring waveform compliance criterion . 45
Bibliography . 46
Figure 1 – Waveform of the ring wave (open-circuit voltage and short-circuit current) . 12
Figure 2 – Example of schematic circuit of the ring wave generator . 14
Figure 3 – Selection of coupling/decoupling method . 16
Figure 4 – Example of coupling network and decoupling network for capacitive
coupling on AC/DC lines: line-to-line coupling . 17
Figure 5 – Example of coupling network and decoupling network for capacitive
coupling on AC/DC lines: line-to-ground coupling . 18
Figure 6 – Example of coupling network and decoupling network for capacitive
coupling on AC lines (three phases): line L3-to-line L2 coupling . 18
Figure 7 – Example of coupling network and decoupling network for capacitive
coupling on AC lines (three phases): line L3-to-ground coupling . 19
Figure 8 – Example of coupling network and decoupling network for unshielded
unsymmetrical interconnection lines: line-to-line and line-to-ground coupling . 20
Figure 9 – Example of coupling and decoupling network for unshielded symmetrical
interconnection lines: lines-to-ground coupling . 21
Figure 10 – Example of coupling and decoupling network for unshielded symmetrical
interconnection lines: lines-to-ground coupling via capacitors . 22
Figure 11 – Example of test setup for ring waves applied to shielded lines . 29
– 4 – IEC 61000-4-12:2017 © IEC 2017
Table 1 – Test levels . 13
Table 2 – Relationship between peak open-circuit voltage and peak short-circuit
current . 15
Table 3 – Ring wave specification at the EUT power port of the CDN . 17
Table 4 – Summary of calibration process for CDNs for unsymmetrical interconnection
lines . 24
Table 5 – Ring wave waveform specifications at the EUT port of the CDN for
unsymmetrical interconnection lines . 25
Table 6 – Summary of calibration process for CDNs for symmetrical interconnection
lines . 26
Table 7 – Ring wave waveform specifications at the EUT port of the CDN for
symmetrical interconnection lines . 26
Table B.1 – Power ports: Selection of the test levels (depending on the installation
class) . 36
Table B.2 – Circuits/lines: Selection of the test levels (depending on the installation
class) . 37
Table D.1 – Example of uncertainty budget for ring wave rise time (T ) . 41
Table D.2 – Example of uncertainty budget for the peak of the short-circuit current of
the ring wave (I ) . 42
Pk1
Table D.3 – α factor (Formula (D.3)) of different unidirectional impulse responses
corresponding to the same bandwidth of the system B . 44
IEC 61000-4-12:2017 © IEC 2017 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 4-12: Testing and measurement techniques –
Ring wave immunity test
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-4-12 has been prepared by subcommittee 77B: High
frequency phenomena, of IEC technical Committee 77: Electromagnetic compatibility.
It forms Part 4-12 of IEC 61000. It has the status of a basic EMC publication in accordance
with IEC Guide 107.
This third edition cancels and replaces the second edition published in 2006. This edition
constitutes a technical revision. This edition includes the following significant technical
changes with respect to the previous edition:
a) addition of a mathematical modelling of ring wave waveform;
b) new Annex B on selection of generators and test levels;
c) new Annex C on explanatory notes;
d) new Annex D on measurement uncertainty;
– 6 – IEC 61000-4-12:2017 © IEC 2017
e) addition of high speed CDN;
f) addition of a calibration procedure for CDN.
The text of this International Standard is based on the following documents:
CDV Report on voting
77B/764/CDV 77B/774/RVC
Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61000 series, published under the general title Electromagnetic
compatibility (EMC), can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
IEC 61000-4-12:2017 © IEC 2017 – 7 –
INTRODUCTION
IEC 61000 is published in separate parts according to the following structure:
Part 1: General
General considerations (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of the product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 6: Generic standards
Part 9: Miscellaneous
Each part is further subdivided into several parts, published either as international standards
or as technical specifications or technical reports, some of which have already been published
as sections. Others will be published with the part number followed by a dash and a second
number identifying the subdivision (example: IEC 61000-6-1).
This part is an International Standard which gives immunity requirements and test procedures
related to ring waves. It should be noted that edition 1 of IEC 61000-4-12, published in 1995,
covered immunity tests against two phenomena, ring waves and damped oscillatory waves.
This situation was changed in edition 2, published in 2006, where IEC 61000-4-12 covered
the ring wave phenomena only and the damped oscillatory wave phenomenon was moved into
a new standard IEC 61000-4-18.
– 8 – IEC 61000-4-12:2017 © IEC 2017
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 4-12: Testing and measurement techniques –
Ring wave immunity test
1 Scope
This part of IEC 61000 relates to the immunity requirements and test methods for electrical
and electronic equipment, under operational conditions, to ring waves occurring in low-voltage
power, control and signal lines supplied by public and non-public networks.
The object of this document is to establish a common reference for evaluating the immunity of
electrical and electronic equipment when subjected to ring waves. The test method
documented in this part of IEC 61000 describes a consistent method to assess the immunity
of an equipment or system against a defined phenomenon.
NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC.
As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity
test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and
performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the
evaluation of the value of particular immunity test and test levels for their products.
This document defines:
– test voltage and current waveforms;
– a range of test levels;
– test equipment;
– test setups;
– test procedures.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60050 (all parts), International Electrotechnical Vocabulary (IEV) (available at
www.electropedia.org)
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050 (all parts) as
well as the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
IEC 61000-4-12:2017 © IEC 2017 – 9 –
3.1.1
calibration
set of operations which establishes, by reference to standards, the relationship which exists
under specified conditions, between an indication and a result of a measurement
Note 1 to entry: This term is based on the "uncertainty" approach.
Note 2 to entry: The relationship between the indications and the results of measurement can be expressed, in
principle, by a calibration diagram.
[SOURCE: IEC 60050-311:2001, 311-01-09]
3.1.2
coupling
interaction between circuits, transferring energy from one circuit to another
3.1.3
coupling network
CN
electrical circuit for the purpose of transferring energy from one circuit to another
3.1.4
coupling/decoupling network
CDN
combination of a coupling network and a decoupling network
3.1.5
decoupling network
DN
electrical circuit for the purpose of preventing test voltages applied to the equipment under
test (EUT) from affecting other devices, equipment, or systems which are not under test
3.1.6
immunity (to a disturbance)
ability of a device, equipment, or system to perform without degradation in the presence of an
electromagnetic disturbance
[SOURCE: IEC 60050-161:1990, 161-01-20]
3.1.7
port
particular interface of an equipment, which couples this equipment with the external
electromagnetic environment (IEC 60050-161:1990, 161-01-01) and through which the
equipment is influenced by the environment
[SOURCE: IEC 60050-161:1990, 161-01-27]
3.1.8
ring wave
damped oscillation, whose damping time constant is of the order of one period
[SOURCE: IEC 60050-161:1990, 161-02-30]
3.1.9
rise time
T
r
interval of time between the instants at which the instantaneous value of an impulse first
reaches 10 % value and then the 90 % value
– 10 – IEC 61000-4-12:2017 © IEC 2017
[SOURCE: IEC 60050-161:1990, 161-02-05, modified – the content of the note has been
included in the definition and “pulse” has been changed to “impulse”]
3.1.10
transient (adj and noun)
pertaining to or designating a phenomenon or a quantity which varies between two
consecutive steady states during a time interval short compared with the time-scale of interest
[SOURCE: IEC 60050-161:1990, 161-02-01]
3.1.11
verification
set of operations which is used to check the test equipment system (e.g. the test generator
and its interconnecting cables) to demonstrate that the test system is functioning
Note 1 to entry: The methods used for verification may be different from those used for calibration.
Note 2 to entry: For the purposes of this basic EMC standard this definition is different from the definition given in
IEC 60050-311:2001, 311-01-13.
3.2 Abbreviated terms
AE Auxiliary equipment
CD Coupling device
CDN Coupling/decoupling network
CLD Clamping device
CN Coupling network
DN Decoupling network
EMC Electromagnetic compatibility
EUT Equipment under test
GDT Gas discharge tube
MU Measurement uncertainty
PDF Probability density function
PE Protective earth
RGP Reference ground plane
RWG Ring wave generator
SPD Surge protective device
4 General
4.1 Description of the phenomenon
The ring wave (described in Figure 1) is an oscillatory transient, induced in low-voltage cables
due to the switching of electrical networks and reactive loads, faults and insulation breakdown
of power supply circuits or lightning. It is, in fact, the most diffused phenomenon occurring in
power supply (high voltage, medium voltage, low voltage) networks, as well as in control and
signal lines.
The ring wave is representative of a wide range of electromagnetic environments of
residential, as well as industrial installations. It is suitable for checking the immunity of
equipment in respect of the above-mentioned phenomena, which give rise to impulses
characterized by sharp front-waves that, in the absence of filtering actions, are in the order of
10 ns to a fraction of µs. The duration of these impulses may range from 10 µs to 100 µs.
IEC 61000-4-12:2017 © IEC 2017 – 11 –
The rise time and duration of the impulse are dependent on the propagation characteristics of
the media and the path.
The propagation of the wave in the lines (power and signal) is always subject to reflections,
due to the mismatching impedance (the lines are terminated with loads or connected to
protection devices, input line filters, etc.). These reflections produce oscillations, whose
frequency is related to the propagation speed. The presence of parasitic parameters
(e.g. stray capacitance of components like motors, transformer windings, etc.) are additional
influencing factors.
The rise time can be increased by the low-pass characteristics of the line. This effect is more
relevant for fast rise times (in the order of 10 ns), and less relevant for slow rise times (in the
order of 1 µs).
Another cause of the ring wave is lightning, which itself is characterized by a unidirectional
waveform (standard 1,2/50 µs impulse). Circuits subjected to the indirect effects of lightning
(inductive coupling among lines) are influenced by the derivative of the primary impulse and
the coupling mechanisms involved, which can cause oscillations. The characteristics of the
resulting ring wave depend on the reactive parameters of the ground circuits, metal structures
involved in the lightning current flow, and the propagation in the low-voltage transmission
lines.
The phenomenon, which is created by the above mentioned effects at the equipment ports, is
an oscillatory transient or a ring wave. Oscillatory transients are covered in IEC 61000-4-18. A
ring wave with a defined 0,5 µs rise time and 100 kHz oscillation frequency has been
determined to be typical and is widely used for testing products.
The formula of the ideal waveform of Figure 1, w(t), is as follows:
n
t
t
t
w(t) = A ⋅ K ⋅ ⋅ exp− ⋅cos(βt)
n
t
2
t
1+
t
1
with
2π
T 1
and β = and T = 10 µs
t = ⋅ = 7,21μs
2 ln R T
where the parameters for oscillation period T = 10 µs are:
A = 1; K = 1,81; n = 1,83; t = 0,507 µs
NOTE R is the ratio between Pk and Pk , Pk and Pk . The value of R ensures that the ratios Pk /Pk , Pk /Pk are
2 3 3 4 2 3 3 4
in the range specified by this document. The value of R cannot be too small otherwise the ratio Pk /Pk exceeds the
1 2
specified tolerance. R = 2 has been selected. The parameters n and t are adjusted to obtain T = 0,5 μs.
1 1
– 12 – IEC 61000-4-12:2017 © IEC 2017
Pk (U or I )
1 Pk Pk
1 1
100 %
90 %
T
Pk
10 %
t
T Pk
1 4
110 % to 40%
Pk
IEC
Key
T Rise time
T Oscillation period
NOTE Only Pk is specified for the current waveform.
Figure 1 – Waveform of the ring wave
(open-circuit voltage and short-circuit current)
Other IEC standards, such as IEC 61000-4-5, refer to the 1,2/50 µs standard lightning
impulse, which may be considered to be complementary to the ring wave described in this
document.
It is the responsibility of the product committees to define the most appropriate test, according
to the phenomenon considered as relevant.
4.2 Relevant parameters
4.2.1 Repetition rate
The repetition rate of the transient is directly related to the frequency of occurrence of the
primary phenomenon (lightning and switching). It is higher whenever the primary cause is the
load switching in control lines, and less frequent in the case of faults and lightning. The
occurrence may typically range from once per second down to once per year.
The repetition rate may be increased in order to reduce the duration of the test. It should be
selected according to the characteristics of the protection device used for
mitigation/suppression of transients.
4.2.2 Phase angle
Equipment failures related to the ring wave on power supply sources can depend on the
phase angle of the AC mains at which the transient is applied. When a protection element
operates during a ring wave test, follow current may occur depending on the phase angle at
which the transient occurs. Follow current is the current from the connected power source that
flows through a protective element, or from any arc in the EUT both during and following the
transient.
U/I
IEC 61000-4-12:2017 © IEC 2017 – 13 –
For semiconductors, the phenomenon may be related to the conduction state of the device at
the time the ring wave occurs. Semiconductor parameters that may be involved, include
forward and reverse recovery characteristics and secondary breakdown performance.
Devices most likely to fail in a phase-related way are semiconductors involved in the power
input circuitry. Other devices in different areas of the EUT can also exhibit such failure
modes.
5 Test levels
The preferred test levels for the ring wave applicable to power, signal and control ports of the
equipment, are given in Table 1. The test level is defined as the voltage of the first peak
(maximum or minimum) in the test waveform (Pk in Figure 1).
Different test levels may apply to power, signal and control ports.
Table 1 – Test levels
Open-circuit test voltage
Level kV
b
Line-to-line Line-to-ground
1 0,25 0,5
2 0,5 1
3 1 2
4 2 4
a
X Special Special
a
"X" can be any level, above, below or in between the others. This level shall be specified by product
committees and/or equipment specification.
b
For symmetrical interconnection lines the test can be applied to multiple lines simultaneously with respect to
ground, i.e. “lines to ground”.
The test levels shall be selected according to the installation conditions; classes of installation
are given in Annex C. Annex A gives information on test levels.
The test shall be applied at all test levels in Table 1 up to and including the specified test
level (see 8.3).
For selection of the test levels for the different interfaces, refer to Annex B.
6 Test instrumentation
6.1 Ring wave generator
6.1.1 Ring wave generator circuit
The generator output shall have the capability to operate under short-circuit conditions.
A block diagram of a representative ring wave generator is shown in Figure 2.
– 14 – IEC 61000-4-12:2017 © IEC 2017
R
S
S
R R
1 2
R
U C L C
1 1 2
IEC
Key
U: high-voltage source R : 30 Ω resistor
C : energy storage capacitor R : 12 Ω resistor
1 4
C : filter capacitor L : oscillating circuit coil
2 1
R : charging resistor S : high-voltage switch
1 1
R : filter resistor S : output impedance selector
2 2
Figure 2 – Example of schematic circuit of the ring wave generator
6.1.2 Impedance values
Two values of impedance (see R and R in Figure 2) have been selected as follows:
3 4
• 12 Ω when testing AC/DC power ports and shielded interconnection lines
• 30 Ω when testing unshielded interconnection lines
6.1.3 Performance characteristics of the ring wave generator
A generator with a floating output shall be used.
The generator is a single-shot ring wave generator with the following characteristics,
measured at the output of the generator:
– voltage rise time (T in Figure 1) 0,5 µs ± 30 % (open-circuit condition)
– current rise time (T in Figure 1) 0,2 µs to 1,0 µs (short-circuit condition)
– voltage oscillation frequency (1/T in Figure 1) 100 kHz ± 10 %
NOTE 1 Oscillation frequency is defined as the reciprocal of the period between the first and third zero crossings
after the initial peak.
– decay (voltage only; see Figure 1) 0,4 ≤ ratio of Pk to Pk ≤ 1,1
2 1
0,4 ≤ ratio of Pk to Pk ≤ 0,8
3 2
0,4 ≤ ratio of Pk to Pk ≤ 0,8
4 3
no requirements for Pk onwards
– repetition rate 1/min or faster
– output impedance see Table 2
NOTE 2 The output impedance is calculated from the open-circuit voltage U divided by the short-circuit current
Pk1
I
Pk1
– open-circuit voltage U (see Figure 1) adjustable from 0,25 kV to the required
Pk1
test level
– short-circuit current I (see Figure 1) see Table 2
Pk1
– phase shifting in a range between 0° to 360° relative to the
phase angle of the AC line voltage to the EUT
with a tolerance of ±10°
IEC 61000-4-12:2017 © IEC 2017 – 15 –
– polarity of Pk (see Figure 1) positive and negative
Table 2 – Relationship between peak open-circuit voltage
and peak short-circuit current
Open-circuit peak voltage ± 10 % Short-circuit peak current ± 10 % Short-circuit peak current ± 10 %
at generator output at 12 Ω generator output at 30 Ω generator output
0,25 kV 20,8 A 8,3 A
0,5 kV 41,7 A 16,7 A
1,0 kV 83,3 A 33,3 A
2,0 kV 166,7 A 66,7 A
4,0 kV 333,3 A 133,3 A
6.1.4 Calibration of the ring wave generator
The test generator characteristics shall be calibrated in order to establish that they meet the
requirements of this document. For this purpose the following procedure shall be undertaken.
The generator output shall be connected to a measurement system with a sufficient bandwidth
(minimum 20 MHz), voltage and current capability to monitor the characteristics of the
waveform.
The characteristics of the generator shall be measured both under open-circuit (load greater
than or equal to 10 kΩ) and short-circuit conditions at the same set voltage.
All performance characteristics stated in 6.1.3, with the exception of phase shifting and
repetition rate, shall be met at the output of the generator. Phase shifting performance shall
be met at the output of the CDN at 0°, 90°, 180° and 270° at one polarity.
6.2 Coupling/decoupling networks
6.2.1 General
Each coupling/decoupling network (CDN) consists of a coupling network and a decoupling
network as shown in the examples of Figure 4 through Figure 10.
NOTE The coupling capacitors can be part of the CDN or part of the generator or discrete external components.
The coupling network shall be provided with a coupling capacitor suitable for the selected
impedance of the test generator, i.e. ≥3 µF.
On the AC or DC power lines, the decoupling network provides relatively high impedance to
the ring wave transient but at the same time allows current to flow to the EUT. This
impedance allows the voltage waveform to be developed at the output of the
coupling/decoupling network and prevents the ring wave current from flowing back into the AC
or DC power supply. High voltage capacitors are used as the coupling element, sized to allow
the full waveform durations to be coupled to the EUT. The coupling/decoupling network for the
AC or DC power supply shall be designed so that the open-circuit voltage waveform and
short-circuit current waveform meet the requirements of Table 3.
For I/O and communication lines, the series impedance of the decoupling network limits the
available bandwidth for data transmission. Coupling elements can be capacitors, in cases
where the line tolerates the capacitive loading effects, clamping devices or arrestors. When
coupling to interconnection lines, the waveforms may be distorted by the coupling
mechanisms which are described in 6.2.3.
– 16 – IEC 61000-4-12:2017 ©
...
The article discusses the release of the standard EN 61000-4-12:2017, which is about testing and measuring electromagnetic compatibility (EMC) for electrical and electronic equipment. Specifically, it focuses on the immunity requirements and test methods for ring waves in low-voltage power, control, and signal lines. The standard aims to provide a common reference for evaluating the immunity of equipment to ring waves. The new edition includes technical changes such as the inclusion of a mathematical model of the ring wave waveform and the addition of new annexes addressing generator and test level selection, explanatory notes, measurement uncertainty, and the calibration procedure for common mode disturbance networks (CDN).
記事のタイトル:EN 61000-4-12:2017 - 電磁両立性(EMC)- 部分4-12:試験および計測技術- リングウェーブ耐性試験 記事の内容:新しい! IEC 61000-4-12:2017は、以前の版との技術内容の変更を示す国際標準とそのレッドラインバージョン(IEC 61000-4-12:2017 RLV)として入手可能です。 IEC 61000-4-12:2017は、公共および非公共ネットワークから供給される低電圧電力、制御および信号線に発生するリングウェーブに対する電気および電子機器の耐性要件と試験方法に関連しています。 この文書の目的は、設備がリングウェーブにさらされた場合における電気および電子機器の耐性を評価するための共通基準を確立することです。 IEC 61000のこの部分に記載された試験方法は、定義された現象に対する設備またはシステムの耐性を評価するための一貫した方法を説明しています。 これはIECガイド107に従い、基本的なEMCパブリケーションの地位を持っています。 この版には、次の重要な技術的変更が前版と比較して含まれています:a)リングウェーブ波形の数学的モデリングの追加;b)選択生成器および試験レベルに関する新しい付録B;c)説明のための新しい付録C;d)測定の不確かさに関する新しい付録D;e)高速CDNの追加;f)CDNのキャリブレーション手順の追加。
기사 제목: EN 61000-4-12:2017 - 전자기적 호환성 (EMC) - 부분 4-12: 시험 및 측정 기법 - 링 웨이브 내성 시험 기사 내용: 새로운! IEC 61000-4-12:2017은 기존 판의 기술 내용과 비교해서 모든 변경 사항을 보여주는 국제 표준과 그의 레드라인 버전인 IEC 61000-4-12:2017 RLV로 사용 가능합니다. IEC 61000-4-12:2017는 공공 및 비공공 네트워크에서 공급되는 저전압 전력, 제어 및 신호선에 발생하는 링 웨이브에 대한 전기 및 전자 장비의 내성 요구사항 및 시험 방법과 관련됩니다. 이 문서의 목적은 링 웨이브에 노출될 때 전기 및 전자 장비의 내성을 평가하기 위한 공통 참조를 정립하는 것입니다. IEC 61000의 이 부분에 기재된 시험 방법은 정의된 현상에 대한 장비 또는 시스템의 내성을 평가하기 위한 일관된 방법을 설명합니다. 이것은 IEC 가이드 107에 따라 기본 EMC 출판물인 지위를 가지고 있습니다. 이 판에는 이전 판과 비교하여 다음과 같은 중요한 기술적 변경 사항이 포함되어 있습니다: a) 링 웨이브 파형의 수학적 모델링 추가; b) 선택적 생성기 및 시험 수준에 대한 새로운 부록 B; c) 설명 참고 사항에 대한 새로운 부록 C; d) 측정 불확실성에 대한 새로운 부록 D; e) 고속 CDN 추가; f) CDN의 교정 절차 추가.








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...