HD 384.4.473 S1:1980
(Main)Electrical installations of buildings - Part 4: Protection for safety - Chapter 47: Application of protective measures for safety - Section 473: Measures of protection against overcurrent
Electrical installations of buildings - Part 4: Protection for safety - Chapter 47: Application of protective measures for safety - Section 473: Measures of protection against overcurrent
Specifies where overload and short-circuit protective devices have to be placed in the run of the conductor. States particular requirements for protection of phase and neutral conductors according to TN, TT and IT systems. Note: -Requirements do not take account of external influences. For application of protective measures in relation to conditions of external influences, see IEC 60364-4-482.
Elektrische Anlagen von Gebäuden - Teil 4: Schutzmaßnahmen - Kapitel 47: Anwendung der Schutzmaßnahmen - Hauptabschnitt 473: Schutzmaßnahmen gegen Überstrom
Installations électriques des bâtiments - Partie 4: Protection pour assurer la sécurité - Chapitre 47: Application des mesures de protection pour assurer la sécurité - Section 473: Mesures de protection contre les surintensités
Spécifie l'endroit où les dispositifs de protection contre les surcharges et contre les courts-circuits doivent être placés sur le parcours du conducteur. Expose les règles particulières pour la protection des conducteurs de phase et de neutre selon les schémas TN, TT et IT. Pour l'application de mesures de protection en fonction des influences externes, voir la IEC 60364-4-482.
Električne inštalacije v zgradbah – 4. del: Varnostne zahteve – 47. poglavje: Uporaba zaščitnih ukrepov – 473. podpoglavje: Nadtokovna zaščita (IEC 60364-4-473:1977, spremenjen)
General Information
- Status
- Withdrawn
- Publication Date
- 13-May-1980
- Technical Committee
- CLC/TC 64 - Electrical installations and protection against electric shock
- Drafting Committee
- IEC/TC 64 - IEC_TC_64
- Parallel Committee
- IEC/TC 64 - IEC_TC_64
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Mar-2013
- Completion Date
- 01-Mar-2013
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Frequently Asked Questions
HD 384.4.473 S1:1980 is a standardization document published by CLC. Its full title is "Electrical installations of buildings - Part 4: Protection for safety - Chapter 47: Application of protective measures for safety - Section 473: Measures of protection against overcurrent". This standard covers: Specifies where overload and short-circuit protective devices have to be placed in the run of the conductor. States particular requirements for protection of phase and neutral conductors according to TN, TT and IT systems. Note: -Requirements do not take account of external influences. For application of protective measures in relation to conditions of external influences, see IEC 60364-4-482.
Specifies where overload and short-circuit protective devices have to be placed in the run of the conductor. States particular requirements for protection of phase and neutral conductors according to TN, TT and IT systems. Note: -Requirements do not take account of external influences. For application of protective measures in relation to conditions of external influences, see IEC 60364-4-482.
HD 384.4.473 S1:1980 has the following relationships with other standards: It is inter standard links to HD 60364-4-43:2010, EN 60204-1:1997, EN 60519-4:1997, EN 60204-1:1992, HD 384.5.52 S1:1995, EN 60204-32:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
HD 384.4.473 S1:1980 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2000
(OHNWULþQHLQãWDODFLMHY]JUDGEDK±GHO9DUQRVWQH]DKWHYH±SRJODYMH
8SRUDED]DãþLWQLKXNUHSRY±SRGSRJODYMH1DGWRNRYQD]DãþLWD,(&
VSUHPHQMHQ
Electrical installations of buildings -- Part 4: Protection for safety -- Chapter 47:
Application of protective measures for safety - Section 473: Measures of protection
against overcurrent
Elektrische Anlagen von Gebäuden -- Teil 4: Schutzmaßnahmen -- Kapitel 47:
Anwendung der Schutzmaßnahmen - Hauptabschnitt 473: Schutzmaßnahmen gegen
Überstrom
Installations électriques des bâtiments -- Partie 4: Protection pour assurer la sécurité --
Chapitre 47: Application des mesures de protection pour assurer la sécurité - Section
473: Mesures de protection contre les surintensités
Ta slovenski standard je istoveten z: HD 384.4.473 S1:1980
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...