Petroleum, petrochemical and natural gas industries - Air-cooled heat exchangers (ISO 13706:2005)

ISO 13706:2005 gives requirements and recommendations for the design, materials, fabrication, inspection, testing and preparation for shipment of air-cooled heat exchangers for use in the petroleum and natural gas industries.
ISO 13706:2005 is applicable to air-cooled heat exchangers with horizontal bundles, but the basic concepts can also be applied to other configurations.

Erdöl-, petrochemische und Erdgasindustrie - Luftgekühlte Wärmeaustauscher (ISO 13706:2005)

Industries du pétrole, de la pétrochimie et du gaz naturel - Echangeurs de chaleur refroidis à l'air (ISO 13706:2005)

Petrokemična industrija ter industrija za predelavo nafte in zemeljskega plina – Zračno hlajeni prenosniki toplote (ISO 13706:2005)

General Information

Status
Withdrawn
Publication Date
14-Oct-2005
Withdrawal Date
30-Nov-2011
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Dec-2011
Completion Date
01-Dec-2011

Relations

Effective Date
22-Dec-2008
Effective Date
14-Dec-2011
Standard

EN ISO 13706:2006

English language
123 pages
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

ABS Group Brazil

ABS Group certification services in Brazil.

Brazil Verified

Sponsored listings

Frequently Asked Questions

EN ISO 13706:2005 is a standard published by the European Committee for Standardization (CEN). Its full title is "Petroleum, petrochemical and natural gas industries - Air-cooled heat exchangers (ISO 13706:2005)". This standard covers: ISO 13706:2005 gives requirements and recommendations for the design, materials, fabrication, inspection, testing and preparation for shipment of air-cooled heat exchangers for use in the petroleum and natural gas industries. ISO 13706:2005 is applicable to air-cooled heat exchangers with horizontal bundles, but the basic concepts can also be applied to other configurations.

ISO 13706:2005 gives requirements and recommendations for the design, materials, fabrication, inspection, testing and preparation for shipment of air-cooled heat exchangers for use in the petroleum and natural gas industries. ISO 13706:2005 is applicable to air-cooled heat exchangers with horizontal bundles, but the basic concepts can also be applied to other configurations.

EN ISO 13706:2005 is classified under the following ICS (International Classification for Standards) categories: 27.060.30 - Boilers and heat exchangers; 75.180.20 - Processing equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

EN ISO 13706:2005 has the following relationships with other standards: It is inter standard links to EN ISO 13706:2000, EN ISO 13706:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN ISO 13706:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Erdöl-, petrochemische und Erdgasindustrie - Luftgekühlte Wärmeaustauscher (ISO 13706:2005)Industries du pétrole, de la pétrochimie et du gaz naturel - Echangeurs de chaleur refroidis a l'air (ISO 13706:2005)Petroleum, petrochemical and natural gas industries - Air-cooled heat exchangers (ISO 13706:2005)75.180.20Predelovalna opremaProcessing equipment71.120.30Prenosniki toploteHeat exchangersICS:Ta slovenski standard je istoveten z:EN ISO 13706:2005SIST EN ISO 13706:2006en,fr01-julij-2006SIST EN ISO 13706:2006SLOVENSKI
STANDARDSIST EN ISO 13706:20001DGRPHãþD

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN ISO 13706October 2005ICS 75.180.20; 27.060.30Supersedes EN ISO 13706:2000
English VersionPetroleum, petrochemical and natural gas industries - Air-cooledheat exchangers (ISO 13706:2005)Industries du pétrole, de la pétrochimie et du gaz naturel -Echangeurs de chaleur refroidis à l'air (ISO 13706:2005)Erdöl- und Erdgasindustrien - Luftgekühlte Wärmetauscher(ISO 13706:2005)This European Standard was approved by CEN on 30 September 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 13706:2005: ESIST EN ISO 13706:2006

Foreword
This document (EN ISO 13706:2005) has been prepared by Technical Committee ISO/TC 67 "Materials, equipment and offshore structures for petroleum and natural gas industries" in collaboration with Technical Committee CEN/TC 12 "Materials, equipment and offshore structures for petroleum and natural gas industries", the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2006, and conflicting national standards shall be withdrawn at the latest by April 2006.
This document supersedes EN ISO 13706:2000.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Endorsement notice
The text of ISO 13706:2005 has been approved by CEN as EN ISO 13706:2005 without any modifications.
Reference numberISO 13706:2005(E)© ISO 2005
INTERNATIONAL STANDARD ISO13706Second edition2005-10-15Petroleum, petrochemical and natural gas industries — Air-cooled heat exchangersIndustries du pétrole, de la pétrochimie et du gaz naturel — Échangeurs de chaleur refroidis à l'air
ISO 13706:2005(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
©
ISO 2005 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 • CH-1211 Geneva 20 Tel.
+ 41 22 749 01 11 Fax
+ 41 22 749 09 47 E-mail
copyright@iso.org Web
www.iso.org Published in Switzerland
ii © ISO 2005 – All rights reserved
ISO 13706:2005(E) © ISO 2005 – All rights reserved iiiContents Page Foreword.v Introduction.vi 1 Scope.1 2 Normative references.1 3 Terms and definitions.2 4 General.4 5 Proposals.5 6 Documentation.5 6.1 Approval information.5 6.2 Final records.6 7 Design.7 7.1 Tube bundle design.7 7.2 Air-side design.19 7.3 Structural design.30 8 Materials.35 8.1 General.35 8.2 Headers.36 8.3 Louvres.36 8.4 Other components.36 9 Fabrication of tube bundle.37 9.1 Welding.37 9.2 Post-weld heat treatment.37 9.3 Tube-to-tubesheet joints.37 9.4 Gasket contact surfaces.39 9.5 Thread lubrication.39 9.6 Alignment and tolerances.39 9.7 Assembly.39 10 Inspection, examination and testing.41 10.1 Quality control.41 10.2 Pressure test.42 10.3 Shop run-in.42 10.4 Equipment performance testing.42 10.5 Nameplates.42 11 Preparation for shipment.42 11.1 General.42 11.2 Surfaces and finishes.43 11.3 Identification and notification.43 12 Supplemental requirements.43 12.1 General.43 12.2 Design.43 12.3 Examination.44 12.4 Testing.44 Annex A (informative)
Recommended practices.45 Annex B (informative)
Checklist, data sheets and electronic data exchange.49 SIST EN ISO 13706:2006

ISO 13706:2005(E) iv © ISO 2005 – All rights reserved Annex C (informative)
Winterization of air-cooled heat exchangers.66 Bibliography.115
ISO 13706:2005(E) © ISO 2005 – All rights reserved vForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 13706 was prepared by Technical Committee ISO/TC 67, Materials, equipment and offshore structures for petroleum, petrochemical and natural gas industries, Subcommittee SC 6, Processing equipment and systems. This second edition cancels and replaces the first edition (ISO 13706:2000), which has been technically revised. SIST EN ISO 13706:2006

ISO 13706:2005(E) vi © ISO 2005 – All rights reserved Introduction Users of this International Standard should be aware that further or differing requirements may be needed for individual applications. This International Standard is not intended to inhibit a vendor from offering, or the purchaser from accepting, alternative equipment or engineering solutions for the individual application. This may be particularly applicable where there is innovative or developing technology. Where an alternative is offered, the vendor should identify any variations from this International Standard and provide details.
INTERNATIONAL STANDARD ISO 13706:2005(E) © ISO 2005 – All rights reserved 1Petroleum, petrochemical and natural gas industries — Air-cooled heat exchangers 1 Scope This International Standard gives requirements and recommendations for the design, materials, fabrication, inspection, testing and preparation for shipment of air-cooled heat exchangers for use in the petroleum and natural gas industries. This International Standard is applicable to air-cooled heat exchangers with horizontal bundles, but the basic concepts can also be applied to other configurations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 76, Rolling bearings — Static load ratings ISO 281, Rolling bearings — Dynamic load ratings and rating life ISO 286 (all parts), ISO system of limits and fits ISO 1081, Belt drives — V-belts and V-ribbed belts, and corresponding grooved pulleys — Vocabulary ISO 1459, Metallic coatings — Protection against corrosion by hot dip galvanizing — Guiding principles ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods ISO 2491, Thin parallel keys and their corresponding keyways (Dimensions in millimetres) ISO 3744, Acoustics — Determination of sound power levels of noise sources using sound pressure — Engineering method in an essentially free field over a reflecting plane ISO 4183, Belt drives — Classical and narrow V-belts — Grooved pulleys (system based on datum width) ISO 4184, Belt drives — Classical and narrow V-belts — Lengths in datum system ISO 5287, Belt drives — Narrow V-belts for the automotive industry — Fatigue test ISO 5290, Belt drives — Grooved pulleys for joined narrow V-belts — Groove sections 9N/J, 15N/J and 25N/J (effective system) ISO 8501-1, Preparation of steel substrates before application of paints and related products — Visual assessment of surface cleanliness — Part 1: Rust grades and preparation grades of uncoated steel substrates and of steel substrates after overall removal of previous coatings SIST EN ISO 13706:2006

ISO 13706:2005(E) 2 © ISO 2005 – All rights reserved ISO 9563, Belt drives — Electrical conductivity of antistatic endless synchronous belts — Characteristics and test method AGMA 60011), Design and selection of components for enclosed gear drives AGMA 6010, Standard for spur, helical, herringbone and bevel enclosed drives ASME PTC 302), Air cooled heat exchangers ICC3), International Building Code 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 bank one or more items arranged in a continuous structure 3.2 bare tube surface total area of the outside surfaces of the tubes, based on the length measured between the outside faces of the header tubesheets 3.3 bay one or more tube bundles, serviced by two or more fans, including the structure, plenum and other attendant equipment NOTE Figure 1 shows typical bay arrangements. 3.4 finned surface 〈of a tube〉 total area of the outside surface exposed to air 3.5 forced-draught exchanger exchanger designed with the tube bundles located on the discharge side of the fan 3.6 induced-draught exchanger exchanger designed with the tube bundles located on the suction side of the fan 3.7 item one or more tube bundles for an individual service 3.8 item number purchaser's identification number for an item
1) American Gear Manufacturers' Association, 1500 King Street, Suite 201, Alexandria, VA 22314, USA. 2) American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990, USA. 3) International Code Council Foundation, 10624 Indian Woods Drive, Cincinnati, OH 45242, USA. SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 33.9 pressure design code recognized pressure vessel standard specified or agreed by the purchaser EXAMPLE ASME Section VIII. 3.10 structural code recognized structural standard specified or agreed by the purchaser EXAMPLES AISC M011 and AISC S302. 3.11 tube bundle assembly of headers, tubes and frames
a)
One-bay b)
Two-bay Key 1 tube bundle Figure 1 — Typical bay arrangements SIST EN ISO 13706:2006

ISO 13706:2005(E) 4 © ISO 2005 – All rights reserved 4 General z 4.1 The pressure design code shall be specified or agreed by the purchaser. Pressure components shall comply with the pressure design code and the supplemental requirements given in this International Standard. NOTE A bullet (z) at the beginning of a subclause indicates a requirement for the purchaser to make a decision or provide information (see checklist in Annex B). 4.2 The air-cooled heat exchanger shall be either a forced-draught exchanger or an induced-draught exchanger and shall include the components shown in Figure 2 and any auxiliaries such as ladders, walkways and platforms. 4.3 Annex A, which may be consulted if required, includes for information some recommended mechanical and design details. Annex A also includes precautions for consideration when specifying certain design aspects, including temperature limitations, type of extended surface, tube support methods, type of air-cooled heat exchanger, materials of gasket construction and operational considerations such as walkway access. z 4.4 The vendor shall comply with the applicable local regulations specified by the purchaser. 4.5 In this International Standard, where practical, US Customary units are included in brackets for information.
a)
Forced draught b)
Induced draught Key 1 tube bundle 2 header 3 nozzle 4 supporting column 5 plenum
6 fan 7 fan ring 8 fan deck 9 drive assembly 10 fan guard Figure 2 — Typical components of an air-cooled heat exchanger SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 55 Proposals 5.1 The vendor's proposal shall include a completed data sheet for each item (see example in Annex B). 5.2 A proposal drawing shall be furnished which shows the major dimensions in plan and elevation, and the nozzle sizes and their orientation. 5.3 The proposal shall state whether vertically mounted electric motors shall be shaft up or shaft down. 5.4 The proposal shall fully define the extent of shop assembly and include a general description of the components to be assembled in the field. 5.5 Any proposal for a design that is not fully described in this International Standard shall include additional drawings sufficient to describe the details of construction. 5.6 The proposal shall include a detailed description of any exceptions to the specified requirements. z 5.7 The proposal shall include noise data. The proposal shall include a noise data sheet (see example in Annex B) if specified by the purchaser. 5.8 The proposal shall include fan performance characteristic curves with the design point marked on the curves. 5.9 The proposal shall include details of the method used to secure the fin ends, see 7.1.11.7. 6 Documentation 6.1 Approval information z 6.1.1 For each item number, the vendor shall produce documents which include the following information. The purchaser shall specify which documents shall be submitted and which of them shall be subject to approval: a) purchaser's item number, the service, the project name and location, the purchaser's order number and the vendor's shop order number; b) design pressure, maximum allowable working pressure, test pressure, maximum and minimum design temperature, and corrosion allowance; c) any applicable codes and purchase specifications of the purchaser; d) material specifications and grades for all pressure parts; e) overall dimensions; f) dimensions and locations of supports and sizes of holding-down bolts; g) nozzle size, rating, facing, location, projection beyond header surface, allowable loadings (forces and moments) and direction of flow; h) drive mount details; i) masses of the tube bundle, the exchanger empty and full of water, and the mass of the heaviest component or combination of components intended by the vendor to be handled in a single lift; j) column reactions for each load type listed in 7.3.3; SIST EN ISO 13706:2006

ISO 13706:2005(E) 6 © ISO 2005 – All rights reserved k) post-weld heat treatment requirements; l) radiographic and other non-destructive examination requirements; m) surface preparation and painting requirements; n) design exposure temperatures for mechanical and instrumentation components; o) nameplate and its position; p) tube-to-tubesheet joint and details of joint preparation. q) plug torque values with recommended thread lubrication. 6.1.2 The vendor shall also furnish gasket detail drawings, field assembly drawings, and drawings for all auxiliary equipment and controls furnished. Drawings shall show electrical and control connections, including those of motive and signal air for any pneumatically actuated louvres or fans. The gasket details shall include type and material, and shall be shown on a separate drawing. z 6.1.3 Calculations required by the pressure design code shall be made for the design of pressure components, including header boxes, tubes and tube joints. Additionally, sufficient detail shall be supplied for any non-standard pressure boundary components, such as swage-type transition nozzles. If specified by the purchaser, the calculations shall be submitted for approval. z 6.1.4 If specified by the purchaser, weld maps, all proposed welding procedures, including tube to tubesheet welding procedures and qualifications (including impact test results, if applicable) shall be submitted for approval prior to fabrication. z 6.1.5 Further engineering information required from the vendor for installation, operation, maintenance, or inspection shall be a matter of agreement between the purchaser and the vendor. 6.2 Final records 6.2.1 The vendor shall maintain records of the materials used and fabrication details for at least 10 years. z 6.2.2 The purchaser shall specify which of the following shall be furnished, and shall specify if any of them shall be in an electronic medium: a) an “as-built” data sheet, including material specifications and grades for all pressure parts; b) a manufacturer's data report in accordance with the pressure design code; c) certified material test reports for all pressure parts; d) fan and hub data, including shaft bore and keyway dimensions and coupling and sheave data; e) a schematic diagram for automatically controlled fan pitch or louvre blade adjustment, if the controller is furnished by the vendor; f) installation, operation and maintenance instructions, including the type of lubrication furnished for gears and bearings; g) parts list; h) a certified noise data sheet for the air-cooled heat exchanger with the fans operating at rated speed and at design conditions; i) fan performance characteristic curves showing the operating point and shaft power consumption; SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 7j) louvre characteristic performance curve; k) temperature recorder charts made during post-weld heat treatment of the headers; l) non-destructive testing records. 7 Design 7.1 Tube bundle design 7.1.1 General 7.1.1.1 Tube bundles shall be rigid, self-contained, and designed for handling as a complete assembly. 7.1.1.2 The vendor shall make provision for lateral movement of exchanger tube bundles of at least 6 mm (1/4 in) in both directions or 12,7 mm (1/2 in) in only one direction, unless the purchaser and the vendor agree on a different value. 7.1.1.3 Provision shall be made to accommodate thermal expansion of tubes. 7.1.1.4 All tubes shall be supported to prevent sagging and meshing or deformation of fins. Tube supports shall be spaced not more than 1,83 m (6 ft) from centre to centre. 7.1.1.5 A hold-down member (tube keeper) shall be provided at each tube support. Hold-down members shall be attached to side frames by bolting. 7.1.1.6 Tubes of single-pass condensers shall be sloped downward at least 10 mm/m (1/8 in/ft) towards the outlet header. 7.1.1.7 Tubes of multi-pass condensers need not be sloped. 7.1.1.8 Air seals shall be provided throughout the tube bundle and the bay to minimize air leakage and bypassing. Any air gap that exceeds 10 mm (3/8 in) in width shall be sealed. 7.1.1.9 The minimum thickness of metal used for air seal construction shall be 2,7 mm (12 gauge USS) (0,105 in) within the bundle side frame and 1,9 mm (14 gauge USS) (0,08 in) outside the bundle side frame. NOTE USS is US Standard for sheet and plate iron and steel. 7.1.1.10 Bolts for removable air seals shall be at least 10 mm (3/8 in) nominal diameter. z 7.1.1.11 Winterization shall be as specified or agreed by the purchaser. Annex C should be used. z 7.1.1.12 The exchanger shall be designed for an internal steam-out operation at the temperature, pressure, and operating conditions if specified by the purchaser. 7.1.2 Heating coils 7.1.2.1 Heating coils provided to protect the tube bundle against freeze-up shall be in a separate bundle, and not part of the tube bundle. 7.1.2.2 Heating coils shall cover the full width of the tube bundle. 7.1.2.3 The tube pitch of the heating coil shall not exceed twice the tube pitch of the tube bundle. 7.1.2.4 If steam is used as heating fluid, heating coils shall be single pass, and the tubes shall be sloped downward at least 10 mm/m (1/8 in/ft) towards the outlet. SIST EN ISO 13706:2006

ISO 13706:2005(E) 8 © ISO 2005 – All rights reserved 7.1.2.5 Pipe-type headers with welded-in tubes may be used for steam service. 7.1.3 Tube bundle design temperature z 7.1.3.1 The maximum and minimum design temperatures for pressure parts shall be as specified by the purchaser. z 7.1.3.2 The purchaser shall separately specify the maximum operating temperature to be applied for fin type selection (the fin design temperature). The design temperatures for pressure parts are not intended to govern fin type selection or to apply in determining exposure temperatures of mechanical and instrumentation components. 7.1.4 Tube bundle design pressure z The design pressure shall be as specified by the purchaser. 7.1.5 Corrosion allowance z 7.1.5.1 The corrosion allowance shall be as specified by the purchaser for all surfaces exposed to the process fluid, except that no corrosion allowance shall be provided for tubes, gaskets or gasket contact surfaces. If not specified, a minimum corrosion allowance of 3 mm (1/8 in) shall be provided for carbon and low-alloy steel components. 7.1.5.2 The corrosion allowance shall be provided on each side of pass partition plates or stiffeners. 7.1.5.3 A thickness equal to the depth of the pass partition groove may be considered as available corrosion allowance on grooved cover plate and tubesheet surfaces. 7.1.6 Headers 7.1.6.1 General z 7.1.6.1.1 Headers shall be designed to prevent excessive warpage of tubesheets and/or leakage at tube joints. The analysis shall consider maximum operating temperature and maximum cooling conditions at minimum ambient air temperature. If specified by the purchaser, the analysis shall consider alternative operations such as low process flow at low ambient air temperature, freezing of fluids in tubes, steam-out, loss of fans due to power failure, and cycling conditions. 7.1.6.1.2 If the fluid temperature difference between the inlet and the outlet of a multi-pass bundle exceeds 110 °C (200 °F), U-tube construction, split headers or other methods of restraint relief shall be employed. 7.1.6.1.3 The need for restraint relief in single- or multi-pass bundles shall be investigated regardless of the fluid temperature difference between the inlet and outlet of the bundle. The designer shall provide calculations to prove the adequacy of the design. Some of the stresses are additive, and tube joint efficiency shall be considered. Calculations shall consider the following stress combinations: a) For tube stress and/or tube joint stress: 1) stress caused by pressure and temperature; 2) stress caused by nozzle forces and moments; 3) stress caused by differential tube expansion (including that caused by waxing or fouling) between rows/passes in the coil sections; 4) stress caused by lateral header movement. SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 9b) For header and nozzle stress: 1) stress caused by temperature and pressure; 2) stress caused by nozzle forces and moments; NOTE Forces and moment can induce movement of the header, see Note in 7.1.10.2. 3) stress caused by differential tube expansion between rows/passes in the coil sections. c) For header attachments and supports (including coil side frames and cooler structure): 1) stress caused by mass of header full of
water; 2) stress caused by nozzle forces and moments; NOTE Forces and moment can induce movement of the header, see Note in 7.1.10.2. 3) stress caused by tube expansion. NOTE There can be additional loads and stresses imposed on the tube bundle that have not been stated above (e.g. seismic). 7.1.6.1.4 Headers shall be designed so that the cross-sectional flow area of each pass is at least 100 % of the flow area in the corresponding tube pass. 7.1.6.1.5 The lateral velocity in the header shall not exceed the velocity in the nozzle. Multiple nozzles or an increased header cross-sectional area may be required. 7.1.6.1.6 The minimum nominal thickness of header components shall be as shown in Table 1. Table 1 — Minimum nominal thickness of header components Component Minimum thickness
Carbon or low-alloy steel High-alloy steel or other material Tubesheet 19 mm (3/4 in) 16 mm (5/8 in) Plug sheet 19 mm (3/4 in) 16 mm (5/8 in) Top, bottom and end plates 12 mm (1/2 in) 10 mm (3/8 in) Removable cover plates 25 mm (1 in) 22 mm (7/8 in) Pass partition plates and stay plates 12 mm (1/2 in) 6 mm (1/4 in) NOTE The thickness indicated for any carbon or low-alloy steel component includes a corrosion allowance of up to 3 mm (1/8 in). The thickness indicated for any component of high-alloy steel or other material does not include a corrosion allowance. The thickness is based on an expanded tube-to-tubesheet joint with one groove. 7.1.6.1.7 Pass partitions used as stay plates for the tubesheet and plug sheet shall be made of one integral plate. 7.1.6.1.8 Header types other than those described in 7.1.6.2 or 7.1.6.3 may be proposed as an alternative design (see Clause 12). SIST EN ISO 13706:2006

ISO 13706:2005(E) 10 © ISO 2005 – All rights reserved 7.1.6.2 Removable cover plate and removable bonnet headers 7.1.6.2.1 The cover plate header design shall permit removal of the cover without disturbing header piping connections. Figure 3a) shows typical construction of tube bundles with removable cover plate headers. 7.1.6.2.2 The bonnet header design shall permit removal of the bonnet with the minimum dismantling of header piping connections. Figure 3 b) shows typical construction of tube bundles with removable bonnet headers. 7.1.6.2.3 Bolted joints shall be designed using through bolts with either confined gaskets or unconfined full-face gaskets. Stud bolt construction may be used if approved by the purchaser. Gasket contact surfaces on cover plates, matching header box flanges and tubesheets shall be machined. The surface finish shall be appropriate for the type of gasket (A.7 may be consulted for guidance on this).Typical constructions are shown in Figure 4. 7.1.6.2.4 Either jackscrews or a minimum clearance of 5 mm (3/16 in) shall be provided at the cover periphery to facilitate dismantling. 7.1.6.2.5 Stay-bolts shall not be used. 7.1.6.2.6 For stud type construction, provision (e.g. sliding pins) shall be made to prevent damage to the studs during handling of the cover plate. 7.1.6.2.7 The minimum nominal diameter of through-bolts shall be 16 mm (5/8 in). The minimum nominal diameter of stud bolts shall be 20 mm (3/4 in). 7.1.6.2.8 The maximum spacing between bolt centres shall be in accordance with the pressure design code. 7.1.6.2.9 The minimum spacing between bolt centres shall be as shown in Table 2. SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 11 a)
Removable cover-plate header
b)
Removable bonnet header Key
1 tubesheet 2 removable cover plate 3 removable bonnet 4 top and bottom plates 5 tube 6 pass partition 7 gasket 8 nozzle 9 side frame 10 tube spacer 11 tube support cross-member 12 tube keeper 13 vent 14 drain 15 instrument connection Figure 3 — Typical construction of tube bundles with removable cover plate and removable bonnet headers SIST EN ISO 13706:2006

ISO 13706:2005(E) 12 © ISO 2005 – All rights reserved
a)
Flanged construction, confined gasket b)
Flanged construction, semi-confined gasket c)
Flanged construction, non-confined gasket Figure 4 — Typical confined and full-faced gasket joint details Table 2 — Minimum flange bolt spacing Nominal bolt diameter Minimum bolt spacing 16 mm (5/8 in) 38 mm (1 1/2 in) 19 mm (3/4 in) 44 mm (1 3/4 in) 22 mm (7/8 in) 52 mm (2 1/16 in) 25 mm (1 in) 57 mm (2 1/4 in) 29 mm (1 1/8 in) 64 mm (2 1/2 in) 32 mm (1 1/4 in) 71 mm (2 13/16 in) 35 mm (1 3/8 in) 76 mm (3 1/16 in) 38 mm (1 1/2 in) 83 mm (3 1/4 in) 41 mm (1 5/8 in) 89 mm (3 1/2 in) 44 mm (1 3/4 in) 95 mm (3 3/4 in) 48 mm (1 7/8 in) 102 mm (4 in) 51 mm (2 in) 108 mm (4 1/4 in) 7.1.6.2.10 Spacing between bolts straddling corners shall be such that the diagonal distance between bolts adjacent to the corner does not exceed the lesser of the spacing on the sides or the ends. 7.1.6.3 Plug headers 7.1.6.3.1 Threaded plug holes shall be provided opposite the ends of each tube for access. Holes shall be threaded to the full depth of the plug sheet. Figure 5 shows typical construction of a tube bundle with plug headers. 7.1.6.3.2 The nominal thread diameter of the plug holes shall be equal to the outside diameter of the tube plus at least 3 mm (1/8 in). 7.1.6.3.3 Gasket contact surfaces of plug holes shall be spot-faced. The edges of the facing shall be free of burrs. SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 13 Key
1 tubesheet 2 plug sheet 3 top and bottom plates 4 end plate 5 tube 6 pass partition 7 stiffener 8 plug 9 nozzle 10 side frame 11 tube spacer 12 tube support cross-member 13 tube keeper 14 vent 15 drain 16 instrument connection Figure 5 — Typical construction of a tube bundle with plug headers 7.1.7 Plugs for tube access 7.1.7.1 Plugs shall be the shoulder type with straight-threaded shanks. 7.1.7.2 Hollowed plugs shall not be used. 7.1.7.3 Plugs shall have hexagonal heads. The minimum dimension across the flats shall be at least equal to the plug shoulder diameter. 7.1.7.4 The pressure seal shall be maintained by means of a gasket between the flange of the plug and the plug sheet. 7.1.7.5 Positive means (such as a self-centring taper) shall be provided to ensure seating of the gasket in the spot-faced recess. SIST EN ISO 13706:2006

ISO 13706:2005(E) 14 © ISO 2005 – All rights reserved 7.1.7.6 Plugs shall be long enough to fill the plug sheet threads, with a tolerance of ± 1,5 mm (1/16 in), except for galling materials or if the nominal plug sheet thickness is greater than 50 mm (2 in), for which alternative designs may be used with the approval of the purchaser. Additional factors to consider in selecting the plug design are thread interference, erosion, crevice corrosion and retention of fluid in cavities. 7.1.7.7 The thickness of the plug head from its gasket surface to the top face shall be at least 50 % of the nominal tube outside diameter. Greater thickness may be required due to pressure rating and material considerations. 7.1.7.8 Threads of plugs having nominal diameters 30 mm (1 1/4 in) and smaller shall be fine series threads. 7.1.8 Gaskets 7.1.8.1 Plug gaskets shall be of the solid-metal or double-metal-jacketed, filled type, of the same general material classification as the plug. 7.1.8.2 Plug gaskets shall be flat and free of burrs. 7.1.8.3 The minimum thickness of solid metal plug gaskets shall be 1,5 mm (0,060 in). 7.1.8.4 For joint type a) in Figure 4, cover plate and bonnet gaskets shall be of the double-metal-jacketed, filled type. Filler material shall be non-asbestos and shall be suitable for sealing, exposure resistance and fire safety performance. 7.1.8.5 For joint type b) in Figure 4, double-metal-jacketed, filled type gaskets or [at design pressures of 2 100 kPa gauge (300 psig) or less] compressed sheet composition gaskets suitable for the service shall be used. Gaskets shall be non-asbestos and shall be suitable for sealing, exposure resistance and fire safety performance. 7.1.8.6 For joint type c) in Figure 4, compressed sheet composition gaskets suitable for the service may be used at design pressures of 2 100 kPa gauge (300 psig) or less. Gaskets shall be non-asbestos and shall be suitable for sealing, exposure resistance and fire safety performance. 7.1.8.7 The width of removable cover plate and removable bonnet gaskets shall be at least 10 mm (3/8 in). 7.1.8.8 Gaskets shall be of one piece. 7.1.8.9 A.7 may be consulted for further guidance on gaskets. 7.1.9 Nozzles and other connections 7.1.9.1 Flanges shall be in accordance with the pressure design code unless otherwise specified by purchaser. 7.1.9.2 Connections of nominal size DN 32 (NPS 1 1/4), DN 65 (NPS 2 1/2), DN 90 (NPS 3 1/2), DN 125 (NPS 5) or less than DN 20 (NPS 3/4) shall not be used. 7.1.9.3 Connections DN 40 (NPS 1 1/2) and larger shall be flanged. 7.1.9.4 In hydrogen service [i.e. if the partial pressure of hydrogen is greater than 700 kPa (100 psia)] all connections shall be flanged and slip-on flanges shall not be used. 7.1.9.5 If design conditions require the equivalent of PN 150 (ANSI 900) or higher flange ratings, all connections shall be flanged. 7.1.9.6 The nominal thickness of the nozzle neck, of carbon steel and low-alloy steel flanged connections shall not be less than specified in Table 3. SIST EN ISO 13706:2006

ISO 13706:2005(E) © ISO 2005 – All rights reserved 15Table 3 — Minimum nozzle neck nominal thickness Pipe size DN (NPS) Nozzle neck thickness mm (in) 20 (3/4) 5,56 (0,219) 25 (1) 6,35 (0,250) 40 (1 1/2) 7,14 (0,281) 50 (2) 8,74 (0,344) 80 (3) 11,13 (0,438) 100 (4) 13,49 (0,531) 150 (6) 10,97 (0,432) 200 (8) 12,70 (0,500) 250 (10) 15,09 (0,594) 300 (12) 17,48 (0,688) NOTE The data in this table are taken from ASME B36.10M, using Schedule 160 for sizes up to DN 100 (NPS 4) and Schedule 80 for the larger sizes. 7.1.9.7 The facing of process flanges shall be in a horizontal plane unless another arrangement is specified by the purchaser. 7.1.9.8 Flanged carbon steel connections shall be one of the following types: a) a forged or centrifugally cast, integrally flanged welding neck; b) a pipe welded to a forged or centrifugally cast welding neck flange; c) a seamless transition piece attached to a forged or centrifugally cast welding neck flange; d) a cast or fabricated transition, if allowed by the purchaser; e) a pipe or a seamless transition welded to a forged slip-on flange. 7.1.9.9 If a transition is used, stay bars, greater header thickness or greater nozzle thickness may be required to provide adequate mechanical strength. 7.1.9.10 Except in hydrogen service (see 7.1.9.4), forged carbon steel slip-on flanges may be used on connections to headers that are limited to: a) a maximum design pressure of 2 100 kPa gauge (300 psig); b) a maximum design temperature of 450 °C (850 °F); c) a maximum service corrosion allowance of 3 mm (1/8 in). 7.1.9.11 Threaded connections shall be DN 25 (NPS 1), except that pressure gauge connections shall be DN 20 (NPS 3/4). 7.1.9.12 Threaded connections shall be one of the following types and shall comply with the pressure design code: a) forged steel full-coupling threaded one end only, with a suitable rating (e.g. ASME B16.11, class 6 000); b) forged steel fitting with integral reinforcement; c) tapped holes for vent and drain connections, where header plate thickness permits; d) equivalent boss connection. SIST EN ISO 13706:2006

ISO 13706:2005(E) 16 © ISO 2005 – All rights reserved 7.1.9.13 If a thermowell connection is specified, it shall be located in the nozzle unless the nozzle is smaller than DN 100 (NPS 4), in which case the connection shall be located on the header adjacent to the nozzle. 7.1.9.14 If a pressure gauge connection is specified it shall be located on the nozzle unless the nozzle is smaller than DN 80 (NPS 3), in which case the connection shall be located on the header adjacent to the nozzle. 7.1.9.15 Pipe threads shall be taper pipe threads (e.g. ASME B1.20.1) and shall comply with the pressure design code. z 7.1.9.16 The size, type and location of chemical cleaning connections, if any, shall be specified by the purchaser. 7.1.9.17 If specified, instrument connections shall be located in at least one inlet and outlet nozzle per bundle, except that none are required in intermediate nozzles of stacked bundles. 7.1.9.18 All threaded piping connections shall be closed with a round-headed solid plug. 7.1.9.19 Flanged auxiliary connections, if any, shall be closed with blind flanges. The gasket and bolting materials shall be suitable for the specified operating conditions. 7.1.9.20 Vent and drain connections shall be provided at high and low points respectively on each header. Header nozzles installed at high and low points may serve as vents and drains. Connections serving as vents and drains shall not extend into the header beyond the inside surface. 7.1.9.21 If the header thickness will not permit minimum thread engagement of vent and drain plugs, couplings or built-up bosses shall be installed. 7.1.9.22 Bolts between connecting nozzles of stacked tube bundles shall be removable without moving the bundles. 7.1.10 Maximum allowable moments and forces for nozzles and headers 7.1.10.1 Each nozzle, in its d
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...