Abstract

This document is published as a dual logo standard and is applicable for the explosion protection requirements for the construction, testing and marking for Group I Ex Equipment that can be an individual item, or be an assembly of multiple items of Ex Equipment and Ex Components forming mining machinery. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it can be assumed that Ex Equipment can be operated are: - temperature −20 °C to +60 °C; - pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and - air with normal oxygen content, typically a volume fraction of 21 %. This part of ISO/IEC 80079 applies for Ex Equipment and Ex Components with Explosion Protection Levels (EPLs) Ma and Mb. This document supplements and modifies the general requirements of IEC 60079‑0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document can be used for guidance on underground applications where firedamp or coal dust can be present, but which are not Group I mines, for example tunnels. This second edition cancels and replaces the first edition, published in 2016. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 2.0 and the previous edition of the document.

Status
Not Published
Publication Date
01-Nov-2026
Current Stage
6055 - CEN Ratification completed (DOR) - Publishing
Start Date
01-Sep-2026
Due Date
01-Sep-2026
Completion Date
01-Sep-2026

Buy Documents

Draft

prEN ISO 80079-38:2025

English language (45 pages)
Preview
Preview
e-Library read for
×1 day

FprEN ISO/IEC 80079-38 is a dual-logo standard for explosive atmospheres in underground mines, published by CEN with ISO/IEC involvement. It specifies explosion protection requirements for the construction, testing and marking of Group I Ex Equipment and Ex Components, including assemblies that form mining machinery, for Explosion Protection Levels (EPLs) Ma and Mb.

What does FprEN ISO/IEC 80079-38 specify?

FprEN ISO/IEC 80079-38 covers explosion protection for Ex Equipment and Ex Components used in underground mines that may contain firedamp, combustible dust, or both. It also gives guidance for similar underground applications, such as tunnels, when firedamp or coal dust may be present and the situation is not classified as a mine.

The standard is organized into clauses on scope, normative references, terms and definitions, general requirements, equipment-specific requirements, EPL Ma equipment using two independent protection means, fire protection, information for use, and marking. It also includes two informative annexes: one worked example and one guidance annex.

The scope assumes these atmospheric conditions for operation:

  • temperature from -20 °C to +60 °C
  • pressure from 80 kPa to 110 kPa
  • air with normal oxygen content, typically about 21 % by volume

It supplements and modifies IEC 60079-0. Where a requirement here conflicts with IEC 60079-0, this document takes precedence.

AnnexWhat it covers
Annex AInformative example of an ignition hazard assessment for a coal mine shearer
Annex BInformative additional guidance on temperature, dust, protection devices, cables, cutting equipment and cable reels

What are the key requirements of FprEN ISO/IEC 80079-38?

FprEN ISO/IEC 80079-38 sets the practical explosion-protection rules for mining equipment design, integration, verification and marking. The most important point is that a mining machine is not treated as a simple collection of certified parts: the assembly, the connections between parts, and the residual ignition hazards all have to be addressed.

General explosion-protection baseline

Clause 4 requires Ex Equipment and Ex Components to meet the relevant EPL Ma or Mb requirements for Group I. If equipment is installed on a mining machine, the certificate conditions or schedule of limitations must be followed, and residual conditions may need an “X” suffix and supporting instructions.

Clause 4.2 requires an ignition hazard assessment using ISO 80079-36. The documentation must cover hazards controlled within the assembly and hazards left to the end-user installation. In practice, this means the manufacturer has to show how ignition sources are prevented, controlled, or passed on as installation conditions.

Non-electrical and electrical equipment

Clause 4.3 requires all non-electrical Ex Equipment and Ex Components, including connecting parts, to comply with ISO 80079-36 and, where needed, another suitable type of protection. Clause 4.4 requires all electrical Ex Equipment and Ex Components to comply with IEC 60079-0 and at least one Group I protection concept.

Clause 4.4 then adds mining-specific electrical measures:

  • overload protection for motors and supply cables
  • short-circuit protection for external cables
  • earth-fault protection and continuous protective conductors
  • safe charging of batteries in explosive atmospheres only from intrinsically safe circuits
  • mechanical protection of live parts against mining damage
  • construction rules for electric cables that form part of the equipment

In practice, these requirements are there to stop overheating, arcing, and insulation faults from becoming ignition sources.

Equipment-specific rules

Clause 5 adds special requirements for the mining equipment types most likely to create ignition risks. Cutting and stripping equipment needs either ventilation to the cutting zone, water sprays to the cutting picks, or both, with interlocks and monitored minimum flow or air conditions. Fans, brakes, compressors, drilling equipment, batteries, optical radiation systems, electromagnetic and ultrasonic sources, and gas monitoring systems each have their own requirements.

This matters because the document does not rely on one generic protection method. It links the protection method to the hazard created by each machine function.

EPL Ma by two independent protection means

Clause 6 is specific to EPL Ma equipment using two independent means of protection. The outer enclosure and the inner apparatus must each meet the relevant protection concept, and each protection type must be checkable on its own. The clause also limits which protection concepts may be combined inside enclosures with free space or without free space.

For manufacturers, this clause is important when a machine achieves Ma status by combining protection methods such as flameproof enclosure, pressurization, encapsulation, powder filling, intrinsic safety, increased safety, or constructional safety.

Fire protection, instructions and marking

Clause 7 requires fire-resistant materials where the ignition hazard assessment shows they are needed, and it includes requirements for hydraulic and pneumatic systems, fire-resistant fluids, cable-reeling equipment, and fire-retardant self-extinguishing cable sheaths. Clause 8 requires warnings and instructions for use, maintenance and repair, including residual risks and emergency actions. Clause 9 sets the marking rules, including the use of “80079-38” in the protection symbol and the EPL marking for the complete mining machine.

What terms does FprEN ISO/IEC 80079-38 define?

  • Firedamp - a flammable mixture of gases naturally occurring in a mine, mainly methane with other gases present in smaller amounts.
  • Ex Component - equipment intended to be part of Ex Equipment, marked with the symbol “U”, and not intended to be used alone.
  • Ex Equipment - explosion-protected equipment, which may include Ex Components but needs evaluation as part of the final equipment.
  • Mining machinery or mining machine - an assembly fitted with, or intended to be fitted with, a drive system and used in mines.
  • Equipment Protection Level (EPL) - the level of protection assigned to equipment according to its likelihood of becoming an ignition source.
  • EPL Ma - equipment for mines susceptible to firedamp with a very high level of protection, suitable even if energized during an outbreak of gas.
  • EPL Mb - equipment for mines susceptible to firedamp with a high level of protection, suitable for normal operation and expected malfunctions until it is de-energized.
  • Safety device - a device that contributes to the safe functioning of Ex Equipment or protective systems with respect to explosion risk.

Who uses FprEN ISO/IEC 80079-38?

FprEN ISO/IEC 80079-38 is used by manufacturers of underground mining machinery, Ex Equipment and Ex Components. It is also used by design engineers, safety engineers, test laboratories, certification bodies, quality managers and mine operators.

In practice, they use it to decide protection concepts, perform ignition hazard assessments, define instructions and warnings, verify cable and enclosure design, apply marking, and check whether a machine is suitable for Ma or Mb use in mines with firedamp and coal dust.

What changed in FprEN ISO/IEC 80079-38 from the previous edition?

This second edition cancels and replaces the first edition published in 2016. The foreword describes it as a technical revision.

The listed changes include:

  • scope clarified and narrowed to construction, testing and marking for Group I
  • hand tools removed from the scope
  • scope expanded to cover EPL Ma as well as Mb
  • definitions aligned with IEC 60079-0 and related standards
  • body text revised to mandatory requirements for conformity assessment
  • new clause 6 added for EPL Ma equipment using a second independent means
  • guidance moved into Annex B
  • marking revised for Ma, Mb and Ma/Mb situations
  • gas monitoring updated to IEC 60079-29-0
  • references and examples for conveyor belts and hand tools removed where no longer relevant

Which standards are used with FprEN ISO/IEC 80079-38?

StandardWhat it contributes
IEC 60079-0General requirements for Ex Equipment and baseline marking rules
IEC 60079-1, IEC 60079-5, IEC 60079-11, IEC 60079-18, IEC 60079-25, IEC 60079-28, IEC 60079-29-0, IEC 60079-33Specific protection concepts, intrinsically safe systems, optical radiation, gas detectors and special protection
IEC 60204-1, IEC 60204-11Electrical safety requirements for machinery, including overload and earth-fault functions
IEC 60332-1Fire performance for electric and optical fibre cables
IEC 60529IP degree of protection for enclosures
ISO 340, ISO 14935, ISO 15029-1, ISO/TS 15029-2Fire and ignition test methods for materials and fire-resistant fluids
ISO 630-5, ISO 1940-1, ISO 7010Steel material specification, balancing quality and safety signs
ISO 80079-36, ISO 80079-37Non-electrical ignition protection, constructional safety and control of ignition sources
ISO/IEC 80079-41Requirements for reciprocating internal combustion engines
EN 1676, EN 12163, EN 10025-2Material specifications used in fan construction guidance

What does the FprEN ISO/IEC 80079-38 document contain?

The document contains construction, test and marking requirements that are specific to underground mining machinery and its Ex Equipment and Ex Components. It includes rules for ignition hazard assessment, electrical protection, cable construction, cutting and stripping equipment, fans, compressors, brakes, batteries, gas monitoring and fire protection.

It also contains a worked example in Annex A for a shearer used in a coal mine, with a figure showing the machine layout and a table that records ignition sources and the protection measures used. Annex B provides practical guidance on service temperature, dust deposits, short-circuit protection, earth-fault protection, cables, cutting equipment and cable reels.

The body of the standard also includes tables for fan material combinations and hydraulic-fluid limits, plus marking examples for machine-level and equipment-level use. For certification and design work, these sections are useful because they show what needs to be checked, documented and listed in instructions without turning the document into a simple checklist.

Relations

Effective Date
12-Feb-2026
Effective Date
05-Jun-2024
Effective Date
05-Jun-2024

Buy Documents

Draft

prEN ISO 80079-38:2025

English language (45 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

FprEN ISO/IEC 80079-38 is a draft published by the European Committee for Standardization (CEN). Its full title is "Explosive atmospheres - Part 38: Equipment and components in explosive atmospheres in underground mines (ISO/IEC FDIS 80079-38:2026)". This standard covers: This document is published as a dual logo standard and is applicable for the explosion protection requirements for the construction, testing and marking for Group I Ex Equipment that can be an individual item, or be an assembly of multiple items of Ex Equipment and Ex Components forming mining machinery. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it can be assumed that Ex Equipment can be operated are: - temperature −20 °C to +60 °C; - pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and - air with normal oxygen content, typically a volume fraction of 21 %. This part of ISO/IEC 80079 applies for Ex Equipment and Ex Components with Explosion Protection Levels (EPLs) Ma and Mb. This document supplements and modifies the general requirements of IEC 60079‑0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document can be used for guidance on underground applications where firedamp or coal dust can be present, but which are not Group I mines, for example tunnels. This second edition cancels and replaces the first edition, published in 2016. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 2.0 and the previous edition of the document.

This document is published as a dual logo standard and is applicable for the explosion protection requirements for the construction, testing and marking for Group I Ex Equipment that can be an individual item, or be an assembly of multiple items of Ex Equipment and Ex Components forming mining machinery. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it can be assumed that Ex Equipment can be operated are: - temperature −20 °C to +60 °C; - pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and - air with normal oxygen content, typically a volume fraction of 21 %. This part of ISO/IEC 80079 applies for Ex Equipment and Ex Components with Explosion Protection Levels (EPLs) Ma and Mb. This document supplements and modifies the general requirements of IEC 60079‑0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document can be used for guidance on underground applications where firedamp or coal dust can be present, but which are not Group I mines, for example tunnels. This second edition cancels and replaces the first edition, published in 2016. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 2.0 and the previous edition of the document.

FprEN ISO/IEC 80079-38 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres; 73.100.30 - Equipment for drilling and mine excavation. The ICS classification helps identify the subject area and facilitates finding related standards.

FprEN ISO/IEC 80079-38 has the following relationships with other standards: It is inter standard links to ISO/IEC 80079-38:2026, EN ISO/IEC 80079-38:2016/A1:2018, EN ISO/IEC 80079-38:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

FprEN ISO/IEC 80079-38 is associated with the following European legislation: EU Directives/Regulations: 2014/34/EU, 2023/1230; Standardization Mandates: M/596, M/605. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

FprEN ISO/IEC 80079-38 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 3 FOREWORD
  • 4 INTRODUCTION
  • 5 1 Scope
  • 6 2 Normative references
  • 7 3 Terms, definitions and abbreviated terms
  • 8 4 Requirements for Ex Equipment and Ex Components
  • 9 4.1 General
  • 10 4.2 Ignition hazard assessment
  • 11 4.3 Non-electrical Ex Equipment and Ex Components
  • 12 4.4 Electrical Ex Equipment and Ex Components
  • 13 4.4.1 General
  • 14 4.4.2 Over-current protection
  • 15 4.4.3 Earth-fault protection
  • 16 4.4.4 Charging of cells or batteries
  • 17 4.4.5 Mechanical protection of live parts
  • 18 4.4.6 Electric cables that are part of the Ex Equipment
  • 19 5 Additional requirements for specific Ex Equipment and Ex Components
  • 20 5.1 Cutting and stripping equipment
  • 21 5.1.1 General
  • 22 5.1.2 Mining machines with cutting picks
  • 23 5.1.3 Stripping mining machines
  • 24 5.2 Rope haulages for level and inclined transport
  • 25 5.3 Fans
  • 26 5.3.1 Ventilating fans for use in underground parts of mine
  • 27 5.3.2 Other fans
  • 28 5.4 Internal combustion engines
  • 29 5.5 Air compressors
  • 30 5.6 Drilling Ex Equipment and Ex Components
  • 31 5.7 Brakes
  • 32 5.7.1 Brakes used only for stopping in emergency
  • 33 5.7.2 Service brakes (including friction brakes and fluid based retarders)
  • 34 5.8 Traction batteries, starter batteries and vehicle lighting batteries
  • 35 5.9 Equipment and transmission systems using optical radiation
  • 36 5.10 Electromagnetic and ultrasonic energy radiating equipment
  • 37 5.11 Gas monitoring systems
  • 38 6 EPL Ma equipment having the requisite Level of Protection using a second 39 independent means
  • 40 6.1 General
  • 41 6.2 Requirements for an outer enclosure as the second independent means
  • 42 6.2.1 Temperature rise limits
  • 43 6.2.2 Outer enclosure with free space inside
  • 44 6.2.3 Outer enclosure with no free space inside
  • 45 6.2.4 Prevention of ingress of flammable dust and water
  • 46 6.3 Restriction on internal equipment

227 INTRODUCTION 228 This part of ISO/IEC 80079 specifies requirements for the constructional features of Ex 229 Equipment and Ex Components that may be an individual item or form an assembly, to enable 230 them to be used in mines, or parts of mines, susceptible to explosive atmospheres of firedamp, 231 combustible dust or a combination of the two.

232 Most of the Ex Equipment used on mining machinery complies with the Type of Protection 233 standards as an individual item of equipment, for example motors and switchgear, and they 234 have their own marking requirements. The Type of Protection standards, however, do not deal 235 with the interconnection of Ex Equipment and Ex Components.

236 Both non-electrical Ex Equipment and the interconnection of electrical/non-electrical Ex 237 Equipment might require an ignition hazard assessment.

238 The need for this document arises because of major operational differences between 239 underground mining operations and those in other industries working with, or in, explosive 240 atmospheres. Examples of these differences are:

241 – firedamp can be released during the extraction of coal or other mining where firedamp is 242 trapped; 243 – the ignitability of the atmosphere around Ex Equipment and Ex Components usually 244 depends upon the amount of dilution offered by an active ventilating system; 245 – the atmosphere in the general body of mine air in which machinery is working can change 246 from one that is not explosive to one that is explosive (for example, during an outburst of 247 firedamp) and, depending on the likelihood, this may impact on the EPL required (Ma versus 248 Mb) ; 249 – persons working in the mine are usually situated within the explosive atmosphere; 250 – there is a need to monitor constantly the mine atmosphere at strategic places to ensure that 251 power can be disconnected from all Ex Equipment except EPL Ma Ex Equipment which is 252 suitable for use in a constantly present explosive atmosphere; 253 – in gassy coal mines, an initial explosion of firedamp can raise combustible dust clouds that 254 when ignited commonly provide a significantly more serious explosion; 255 – some mining machinery contains cutting devices and drilling devices that might produce an 256 ignition risk from sparks generated from contact with strata containing high concentrations 257 of quartz or iron pyrites; and 258 – long roadways in coal mines are equipped with mineral conveying systems carrying a 259 product that has a potential for raising a combustible dust cloud and the release of firedamp.

262 EXPLOSIVE ATMOSPHERES – 263 264 Part 38: Equipment and components in explosive 265 atmospheres in underground mines 266 267 1 Scope 268 This part of ISO/IEC 80079 specifies the explosion protection requirements for the construction, 269 testing and marking for Group I of Ex Equipment that can be an individual item, or be an 270 assembly of multiple items of Ex Equipment and Ex Components forming mining machinery. 271 NOTE 1 The Group I designation takes account of the fact coal dust (which is a combustible dust) is expected to 272 be present, with or without the presence of firedamp, which is predominately methane. 273 NOTE 2 The definition of Group I also covers mines other than coal mines that are susceptible to firedamp. 274 NOTE 3 The term “assembly” as used in this document is not identical in meaning to the term “Equipment Assembly” 275 as defined in IEC 60079-46.

276 The standard atmospheric conditions (relating to the explosion characteristics of the 277 atmosphere) under which it can be assumed that Ex Equipment can be operated are:

278 • temperature -20 °C to +60 °C; 279 • pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and 280 • air with normal oxygen content, typically a volume fraction of 21 %.

281 This part of ISO/IEC 80079 applies for Ex Equipment and Ex Components with Explosion 282 Protection Levels (EPLs) Ma and Mb.

283 This document supplements and modifies the general requirements of IEC 60079-0. Where a 284 requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of 285 this document takes precedence.

286 This document is not applicable to tunnelling situations where firedamp or coal dust might be 287 produced if such situations are not classified as mines. However, it might be appropriate to 288 use this document as guidance for those situations.

289 2 Normative references 290 The following documents, in whole or in part, are normatively referenced in this document and 291 are indispensable for its application. For dated references, only the edition cited applies. For 292 undated references, the latest edition of the referenced document (including any amendments) 293 applies.

294 IEC 60079-0, Explosive atmospheres – Part 0: Equipment – General requirements 295 IEC 60079-1, Explosive atmospheres – Part 1: Equipment protection by flameproof enclosures 296 "d" 297 IEC 60079-5, Explosive atmospheres – Part 5: Equipment protection by powder filling "q" 298 IEC 60079-11, Explosive atmospheres – Part 11: Equipment protection by intrinsic safety "i" 299 IEC 60079-18, Explosive atmospheres – Part 18: Equipment protection by encapsulation "m" 300 IEC 60079-25, Explosive atmospheres – Part 25: Intrinsically safe electrical systems 301 IEC 60079-28, Explosive atmospheres – Part 28: Protection of equipment and transmission 302 systems using optical radiation 303 IEC 60079-29-0, Explosive atmospheres – Part 29-0: Gas detectors – General requirements 304 and test methods (under development) 305 IEC 60079-33, Explosive Atmospheres - Part 33: Equipment protection by special protection “s” 306 IEC 60204-1, Safety of machinery – Electrical equipment of machines – Part 1: General 307 requirements 308 IEC 60204-11, Safety of machinery – Electrical equipment of machines – Part 11: Requirements 309 for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV 310 IEC 60332-1 (all parts), Tests on electric and optical fibre cables under fire conditions 311 IEC 60529, Degrees of protection provided by enclosures (IP Code) 312 ISO 340, Conveyor belts – Laboratory scale flammability characteristics – Requirements and 313 test method 314 ISO 630-5, Structural steels – Part 5: Technical delivery conditions for structural steels with 315 improved atmospheric corrosion resistance 316 ISO 1940-1, Mechanical vibration – Balance quality requirements for rotors in a constant (rigid) 317 state – Part 1: Specification and verification of balance tolerances 318 ISO 7010, Graphical symbols – Safety colours and safety signs – Registered safety signs 319 ISO 14935, Petroleum and related products – Determination of wick flame persistence of fire- 320 resistant fluids 321 ISO 15029-1, Petroleum and related products – Determination of spray ignition characteristics 322 of fire-resistant fluids – Part 1: Spray flame persistence – Hollow-cone nozzle method 323 ISO/TS 15029-2, Petroleum and related products – Determination of spray ignition 324 characteristics of fire-resistant fluids – Part 2: Spray test – Stabilized flame heat release method 325 ISO 80079-36 Explosive atmospheres – Part 36: Non-electrical equipment for explosive 326 atmospheres – Basic method and requirements 327 ISO 80079-37, Explosive atmospheres – Part 37: Non-electrical equipment for explosive 328 atmospheres – Non-electrical type of protection constructional safety “c”, control of ignition 329 sources “b”, liquid immersion “k” 330 ISO/IEC 80079-41, Explosive atmospheres - Part 41: Reciprocating internal combustion 331 engines (under development) 332 EN 1676, Aluminium and aluminium alloys – Alloyed ingots for remelting – Specifications 333 EN 12163, Copper and copper alloys – Rod for general purposes 334 EN 10025-2, Hot rolled products of structural steels – Part 2: Technical delivery conditions for 335 non-alloy structural steels 336 3 Terms, definitions and abbreviated terms 337 For the purposes of this document, the following terms and definitions apply. 338 ISO and IEC maintain terminology databases for use in standardization at the following 339 addresses:

340 • IEC Electropedia: available at https://www.electropedia.org/ 341 • ISO Online browsing platform: available at https://www.iso.org/obp 342 NOTE Additional definitions applicable to explosive atmospheres can be found in IEC 60050-426. 343 3.1 344 firedamp 345 flammable mixture of gases naturally occurring in a mine 346 Note 1 to entry: Firedamp consists mainly of methane, but always contains small quantities of other gases, such as 347 nitrogen, carbon dioxide, and hydrogen, and sometimes ethane and carbon monoxide. The terms firedamp and 348 methane are used frequently in mining practice as synonyms.

349 [SOURCE: IEC 60079-0:2017, 3.44] 350 3.2 351 flammable substance 352 substance which is itself flammable, or is capable of producing a flammable gas, vapour or mist 353 [SOURCE: IEC 60079-10-1:2020, 3.6.1 ] 354 3.3 355 Ex Component 356 equipment intended to be part of Ex Equipment, marked with the symbol “U”, which is not 357 intended to be used alone, and requires additional consideration when incorporated into Ex 358 Equipment 359 [SOURCE: IEC 60079-0:2017, 3.36] 360 3.4 361 equipment 362 general term including apparatus, fittings, devices, components, and the like used as a part of 363 or in connection with, an installation 364 [SOURCE: IEC 60079-0:2017, 3.31] 365 3.5 366 Ex Equipment 367 explosion-protected equipment 368 Note 1 to entry: Such equipment often includes Ex Components, but additional evaluation is always required as part 369 of their incorporation into equipment.

370 [SOURCE: IEC 60079-0:2017, 3.37] 371 3.6 372 explosive atmosphere 373 mixture with air, under atmospheric conditions, of flammable substances in the form of gas, 374 vapour, dust, fibres, or flyings which, after ignition, permits self-sustaining propagation 375 [SOURCE: IEC 60079-0:2017, 3.38] 377 mining machinery 378 mining machine 379 assembly, fitted with or intended to be fitted with a drive system consisting of linked parts or 380 components, at least one of which moves, and which are joined together for use in mines 381 Note 1 to entry: The term "machinery" also covers an assembly of machines which, in order to achieve the same 382 end, are arranged and controlled so that they function as an integral whole. 383 3.8 384 malfunction 385 equipment or components which do not perform their intended function with respect to explosion 386 protection 387 Note 1 to entry: For the purposes of this document this can happen due to a variety of reasons, including 388 – failure of one (or more) of the component parts of the equipment or components; 389 – external disturbances (for example shocks, vibration, electromagnetic fields); 390 – design error or deficiency (e.g. software errors); 391 – disturbance of the power supply or other services; 392 – loss of control by the operator (especially for hand-held machines).

393 [SOURCE: IEC 60079-0:2017, 3.56] 394 3.9 395 Equipment Protection level 396 EPL 397 Level of Protection assigned to equipment based on its likelihood of becoming a source of 398 ignition and distinguishing the differences between explosive gas atmospheres, explosive dust 399 atmospheres, and the explosive atmospheres in mines susceptible to firedamp. 400 [SOURCE: IEC 60079-0:2017, 3.33] 401 3.10 402 EPL Ma 403 equipment for installation in a mine susceptible to firedamp, having a " very high" Level of 404 Protection, which has sufficient security that it is unlikely to become an ignition source in normal 405 operation, during expected malfunctions or during rare malfunctions, even when left energized 406 in the presence of an outbreak of gas 407 [SOURCE: IEC 60079-0:2017, 3.33.1] 408 3.11 409 EPL Mb 410 equipment for installation in a mine susceptible to firedamp, having a "high" Level of Protection, 411 which has sufficient security that it is unlikely to become a source of ignition in normal operation 412 or during expected malfunctions in the time span between there being an outbreak of gas and 413 the equipment being de-energized 414 [SOURCE: IEC 60079-0:2017, 3.33.2] 415 3.12 416 maximum surface temperature 417 highest temperature which is attained in service under the most adverse conditions (but within 418 the specified tolerances) by any part or surface of Ex Equipment 419 [SOURCE:IEC 60079-0:2017, 3.57] 421 non-electrical equipment 422 equipment which can achieve its intended function mechanically 423 Note 1 to entry: Equipment addressed in ISO 80079-36 can be powered by any kind of energy including electrical 424 equipment.

425 [SOURCE: ISO 80079-36:2016, 3.7] 426 3.14 427 mechanical sparks 428 sparks, as well as showers of sparks, produced by impact or friction between two similar or 429 dissimilar solid materials 430 3.15 431 incendive sparks 432 mechanical sparks with sufficient thermal energy to ignite a flammable atmosphere 433 3.16 434 hydraulic fluids 435 all fluids and their concentrates for hydraulic transmission and monitoring with exception of 436 water 437 3.17 438 safety device 439 device intended for use inside or outside explosive atmospheres but required for or contributing 440 to the safe functioning of Ex Equipment and protective systems with respect to the risks of 441 explosion 442 Note 1 to entry: Safety devices differ from the term devices used in the IEC 61508 and IEC 61511 series. Safety 443 devices can be compared to the terms like “safety-related system (IEC 61508)” or “safety instrumented system (IEC 444 61511)”.

445 [SOURCE: IEC TS 60079-42:2019, 3.1] 446 4 Requirements for Ex Equipment and Ex Components 447 4.1 General 448 Ex Equipment and Ex Components shall conform with the applicable requirements for EPL Ma 449 or Mb according to the IEC 60079 series for electrical equipment and according to the 450 ISO/IEC 80079 series for non-electrical equipment, for Group I. The requirement for conformity 451 with Ma or Mb will depend on the intended application.

452 When Ex Equipment or Ex Components are installed on a mining machine, the Specific 453 Conditions of Use or the Schedule of Limitations specified in the certificates shall be complied 454 with as part of the assembly or the mining machine certificate number shall include the “X” suffix 455 in accordance with the marking requirements of IEC 60079-0 and the remaining Specific 456 Conditions of Use shall be listed on that certificate.

457 NOTE Typical conditions for Specific Cond

...