Residential cookers fired by solid fuel - Requirements and test methods

This Standard is applicable to hand fired appliances whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occuring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent products or be multi-fuel in accordance with the appliance maufacturer's instructions. This standard is not applicable to hopper fed or mechanically fired appliances or those appliances having fan assisted combustion air.

Herde für feste Brennstoffe - Anforderungen und Prüfungen

Cuisinières domestiques à combustible solide - Exigences et méthodes d'essai

Štedilniki na trdna goriva - Zahteve in preskusne metode

General Information

Status
Withdrawn
Publication Date
14-Sep-2004
Withdrawal Date
20-Dec-2022
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
21-Dec-2022

Relations

Buy Standard

Amendment
EN 12815:2003/A1:2005 en
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Amendment
EN 12815:2003/A1:2005 de
German language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2005
Štedilniki na trdna goriva - Zahteve in preskusne metode
Residential cookers fired by solid fuel - Requirements and test methods
Herde für feste Brennstoffe - Anforderungen und Prüfungen
Cuisinieres domestiques a combustible solide - Exigences et méthodes d'essai
Ta slovenski standard je istoveten z: EN 12815:2001/A1:2004
ICS:
97.040.20 âWHGLOQLNLGHORYQLSXOWL Cooking ranges, working
SHþLFHLQSRGREQLDSDUDWL tables, ovens and similar
appliances
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 12815:2001/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2004
ICS 97.040.20
English version
Residential cookers fired by solid fuel - Requirements and test
methods
Cuisinières domestiques à combustible solide - Exigences Herde für feste Brennstoffe - Anforderungen und Prüfungen
et méthodes d'essai
This amendment A1 modifies the European Standard EN 12815:2001; it was approved by CEN on 18 June 2004.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this
amendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references concerning such
national standards may be obtained on application to the Central Secretariat or to any CEN member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12815:2001/A1:2004: E
worldwide for CEN national Members.

Foreword
This document (EN 12815:2001/A1:2004) has been prepared by Technical Committee CEN/TC 295
“Residential solid fuel burning appliances”, the secretariat of which is held by BSI.

This Amendment to the European Standard EN 12815:2001 shall be given the status of a national standard,
either by publication of an identical text or by endorsement, at the latest by February 2005, and conflicting
national standards shall be withdrawn at the latest by May 2006.

This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directives.

For the relationship with EU Directives, see informative Annex ZA, which is an integral part of this document.

According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland
and United Kingdom.
1 Contents list
Insert the title listing for a new Clause 9 after Clause 8 as follows:

“Clause 9  Evaluation of conformity”

Insert the title listings for new Tables 9 and 10 after Table 8 and before Table A.1 as follows:

“Table 9 – Characteristics to take account of in deciding family of appliances
Table 10 – Performance characteristics to take account of in deciding family of appliances”

Delete the existing contents listing of Table 5 and Table 6

Delete the existing title listing for Annex D and insert a new listing for Annex ZA (after existing Annex C) as
follows:
“Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction
Products Directive
Insert a new title listing for Bibliography after new Annex ZA.

2 Clause 2 Normative references

Add the following new references:

EN 50165 Electrical equipment of non-electric appliances for household and similar purposes —
Safety requirements.
ISO 2859 (all parts) Sampling procedures for inspection by attributes.“

3 Clause 3 Terms and definitions

Delete the existing 3.28 and replace with the following:

“3.28
flue gas connector
duct through which flue gases are conveyed from the flue spigot of the appliance into the chimney flue”

4 Clause 4 Materials, design and construction

4.1 Production documentation
Add the following new text after the first paragraph:

“The parameters and characteristics considered in making the decisions in relation to either the family or range
of appliances to be submitted for initial type testing (see 9.2.1) or further type testing where changes are made
to an appliance (see 9.2.2) shall be recorded. A copy of the parameters and characteristics considered in
making the decisions shall be included in the production documentation for each appliance.”

5 Clause 5 Safety
5.4 Natural draught safety test

Delete the first sentence of 5.4 and replace with the following:

“If the appliance manufacturer claims that the appliance is capable of continuous operation and specifies it may
be installed into a shared flue i.e. a chimney serving more than one appliance, when tested in accordance with
A.4.15, either the flue draught throughout the test period shall be not less than 3 Pa or where the flue draught
falls below 3 Pa then over a further 10 h period from when the draught falls below 3 Pa the total quantity of
carbon monoxide in the flue gas, calculated to NTP as detailed in A.6.2.8 shall not be greater than 250 dm³.”

New sub-clause 5.7
Add a new sub- clause5.7 to cover electrical safety as follows:

“5.7 Electrical safety
The appliance shall comply with the electrical safety requirements of EN 50165 if mains operated electrical
equipment is fitted as part of the appliance.”

6 Clause 6 Performance
6.3 Carbon monoxide emission classes

Delete the existing clause title and the whole of the existing text and the accompanying NOTE of sub-clause 6.3
together with the whole of Table 5 and replace with the following:

“6.3 Carbon monoxide emission
“When measured during the nominal heat output test in accordance with A.4.9, the mean carbon monoxide
concentration calculated to 13% oxygen (O ) content in the flue gas shall be less than or equal to the
manufacturer’s declared value and shall not exceed 1,0%.”

Some countries have existing national legislation which set limits for maximum carbon monoxide concentration
levels under slow combustion, in these cases the carbon monoxide level shall be measured during the slow
combustion test in accordance with A.4.12 for appliances sold in that country.”

6.4 Efficiency at nominal heat output

Delete the existing clause title and the whole of the existing text and the accompanying NOTE of sub-clause 6.4
together with the whole of Table 6 and replace with the following:
“6.4 Efficiency
When tested in accordance with A.4.9, the measured total efficiency from the mean of at least two test results
at nominal heat output shall be greater than or equal to the manufacturer’s declared value and shall equal or
exceed 60 %.
Some countries have existing national legislation which set limits for efficiency under slow combustion
conditions, in these cases the carbon monoxide level shall be measured during the slow combustion test in
accordance with A.4.12 for appliances sold in that country.”

6.5 Refuelling interval at nominal heat output

rd
Add a new 3 paragraph to sub-clause 6.5 as follows:

“The nominal load shall be calculated using the refuelling intervals, the minimum efficiencies and the calorific
values of the fuels as detailed in A.4.2.”

7 Clause 7 Appliance instructions

7.2 Installation instructions
Delete the existing indent 12 of sub-clause 7.2 and replace with the following:

“ – the flue gas mass flow in g/s at nominal heat output if required by national/local regulation (or alternatively
the nominal heat output and the appliance efficiency and mean CO concentration when operating at nominal
heat output should be given for all test fuel types);

8 Clause 8 Marking
Delete the existing indent 3 of Clause 8 and replace with the following three indents:

“ – the measured CO concentration at 13% oxygen content;
– the determined appliance efficiency at nominal heat output;
– the model number and/or designation or type to enable the appliance to be identified;”

9 New Clause 9
Add the following new clause:
“9 Evaluation of conformity
9.1 General
The compliance of a cooker with the requirements of this standard and with the stated values (including
classes) shall be demonstrated by:

- type testing,
- factory production control by the manufacturer, including product assessment.

For the purposes of testing, appliances may be grouped into families, where it is considered that the selected
performance characteristic or characteristics, especially in respect of those detailed in Table 9 and Table 10
is/are common to all appliances within that family.

9.2 Type testing
9.2.1 Initial type testing
Initial type testing shall be performed to demonstrate conformity to this standard. In the case of an appliance
already in production the appliance to be tested shall be chosen at random and be representative of general
production and the manufacturer shall provide a written declaration to this effect.

In the case of a prototype the appliance tested shall be a model representative of the intended future production
and the manufacturer shall provide a written declaration that this is the case. When the appliance goes into
production a dimensional and constructional check shall be undertaken on the production appliance to confirm
it is in agreement with the originally type tested prototype model. If the dimensions of the production appliance
diverge by more than 1 % of the dimension or ± 3 mm whichever is the lesser from that of the prototype in
relation to the firebox and/or combustion chamber and any other dimension considered to be critical to the
safety and performance of the appliance (especially in respect of the characteristics of Table 9 and Table 10)
then the production appliance itself shall be subjected to further type testing as detailed in 9.2.2.

Similarly, if there is a change to the construction materials used which will adversely alter the performance
characteristics of the appliance especially as regards its safety and/or the meeting of the performance
characteristics of Table 10 then the production appliance itself shall be subject to further type testing as detailed
in 9.2.2. This requirement regarding re-testing shall be applied if during the subsequent production or at the
start of a new production run such a change is made to dimensions and/or construction materials. To ensure
that this takes place there shall be a dimensional/constructional check on a current production appliance over
an ongoing period not exceeding 3 years to demonstrate conformity to type.

Where tests have been previously performed in accordance with the provisions of this standard (same product,
same characteristic(s), test method, sampling procedure, system of attestation of conformity, etc.) then the
results of these tests shall be taken into account in assessing continuing conformity to type.

For a family or range of appliance it shall be permissible to test only selected appliances across the family or
range and to only verify selected constructional and performance characteristics on the others, subject to a
clear decision being made that the appliances are part of a family or range of appliances. For the initial type test
at least a sufficient number of the appliances shall be chosen from across the family or range so as to represent
adequately the family or range. The chosen appliances shall be subjected to complete testing to fully verify their
compliance with all of the constructional and performance characteristics in accordance with this standard. For
the other appliances in the family or range not chosen for complete testing it shall be permissible to only verify
selected constructional and/or performance characteristics to ensure their compliance with the requirements of
this standard and/or to ensure they will perform the same as the fully type tested appliances of the family or
range.
In selecting appliances for type testing from a product range based upon their nominal heat outputs as
representing such a family then sufficient appliances from the range shall be chosen for test such that the ratio
of nominal heat output between the appliances does not exceed the ratio of 1,6:1.

Further, in deciding that the appliances belong to a family or range due account shall be taken of the
construction and performance characteristics of each appliance especially in respect of the list of characteristics
detailed in Table 9 and Table 10. The list of characteristics in Table 9 and Table 10 is not definitive and other
aspects may need to be considered in making this judgement. Where a range of appliances of the same
firebox and output have differing canopies or external cladding both in size and materials of construction (eg
where the hot surface would be likely to be closer to combustible surfaces or there is a change from a lower to
a higher conductivity or emissivity material) then at least one appliance shall be chosen which will be the worst
scenario case and will demonstrate the safety of the range as regards surface temperature and safety of
adjacent combustible materials.

Where the manufacturer claims conformity to the standard for a family of appliances on a number of different
fuel types a selection of tests shall be made which demonstrates the conformity of the family in respect of the
safety (Clause 5) and performance (Clause 6) on
...


SLOVENSKI STANDARD
01-april-2005
Štedilniki na trdna goriva - Zahteve in preskusne metode
Residential cookers fired by solid fuel - Requirements and test methods
Herde für feste Brennstoffe - Anforderungen und Prüfungen
Cuisinieres domestiques a combustible solide - Exigences et méthodes d'essai
Ta slovenski standard je istoveten z: EN 12815:2001/A1:2004
ICS:
97.040.20 âWHGLOQLNLGHORYQLSXOWL Cooking ranges, working
SHþLFHLQSRGREQLDSDUDWL tables, ovens and similar
appliances
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPÄISCHE NORM
EN 12815:2001/A1
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2004
ICS 97.040.20
Deutsche Fassung
Herde für feste Brennstoffe - Anforderungen und Prüfungen
Residential cookers fired by solid fuel - Requirements and Cuisinières domestiques à combustible solide - Exigences
test methods et méthodes d'essai
Diese Änderung A1 modifiziert die Europäische Norm EN 12815:2001. Sie wurde vom CEN am 18.Juni 2004 angenommen.
Die CEN-Mitglieder sind gehalten, die CEN/CENELEC-Geschäftsordnung zu erfüllen, in der die Bedingungen festgelegt sind, unter denen
diese Änderung in der betreffenden nationalen Norm, ohne jede Änderung, einzufügen ist. Auf dem letzen Stand befindliche Listen dieser
nationalen Normen mit ihren bibliographischen Angaben sind beim Management-Zentrum oder bei jedem CEN-Mitglied auf Anfrage
erhältlich.
Diese Änderung besteht in drei offiziellen Fassungen (Deutsch, Englisch, Französisch). Eine Fassung in einer anderen Sprache, die von
einem CEN-Mitglied in eigener Verantwortung durch Übersetzung in seine Landessprache gemacht und dem Management-Zentrum
mitgeteilt worden ist, hat den gleichen Status wie die offiziellen Fassungen.
CEN-Mitglieder sind die nationalen Normungsinstitute von Belgien, Dänemark, Deutschland, Estland, Finnland, Frankreich, Griechenland,
Irland, Island, Italien, Lettland, Litauen, Luxemburg, Malta, den Niederlanden, Norwegen, Österreich, Polen, Portugal, Schweden, der
Schweiz, der Slowakei, Slowenien, Spanien, der Tschechischen Republik, Ungarn, dem Vereinigten Königreich und Zypern.
EUROPÄISCHES KOMITEE FÜR NORMUNG
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
Management-Zentrum: rue de Stassart, 36  B-1050 Brüssel
© 2004 CEN Alle Rechte der Verwertung, gleich in welcher Form und in welchem Ref. Nr. EN 12815:2001/A1:2004 D
Verfahren, sind weltweit den nationalen Mitgliedern von CEN vorbehalten.

Vorwort
Dieses Dokument (EN 12815:2001/A1:2004) wurde vom Technischen Komitee CEN/TC 295 „Häusliche
Feuerstätten für feste Brennstoffe“ erarbeitet, dessen Sekretariat vom BSI gehalten wird.
Diese Änderung zur Europäischen Norm EN 12815:2001 muss den Status einer nationalen Norm erhalten,
entweder durch Veröffentlichung eines identischen Textes oder durch Anerkennung bis Februar 2005, und
etwaige entgegenstehende nationale Normen müssen bis Mai 2006 zurückgezogen werden.
Dieses Dokument wurde unter einem Mandat erarbeitet, das die Europäische Kommission und die
Europäische Freihandelszone dem CEN erteilt haben, und unterstützt grundlegende Anforderungen der
EU-Richtlinie(n).
Zum Zusammenhang mit EU-Richtlinie(n) siehe informativen Anhang ZA, der Bestandteil dieses Dokumentes ist.
Entsprechend der CEN/CENELEC-Geschäftsordnung sind die nationalen Normungsinstitute der folgenden
Länder gehalten, diese Europäische Norm zu übernehmen: Belgien, Dänemark, Deutschland, Estland,
Finnland, Frankreich, Griechenland, Irland, Island, Italien, Lettland, Litauen, Luxemburg, Malta, Niederlande,
Norwegen, Österreich, Polen, Portugal, Schweden, Schweiz, Slowakei, Slowenien, Spanien, Tschechische
Republik, Ungarn, Vereinigtes Königreich und Zypern.
1 Inhaltsangabe
Die Überschrift für einen neuen Abschnitt 9 nach Abschnitt 8 ist wie folgt einzufügen:
Abschnitt 9 Konformitätsprüfung
Nach Tabelle 8 und vor Tabelle A.1 ist der Titel des nachfolgenden neuen Tabellen 9 und 10 einzusetzen:
Tabelle 9 – Bei der Entscheidungsfindung hinsichtlich einer Feuerstättengruppe zu berücksichtigende
Merkmale
Tabelle 10 – Leistungsmerkmale, die zur Entscheidung einer Familie von Feuerstätten zu berücksichtigen
sind
Die bestehenden Inhaltsangaben für Tabelle 5 und 5 sind zu streichen.
Die bestehende Inhaltsangabe von Anhang D ist zu streichen und zu ersetzen durch die Inhaltsangabe von
Anhang ZA (nach bestehenden Anhang C) wie folgt:
Anhang ZA (informativ) Abschnitte dieser Europäischen Norm bezüglich der Vorschriften der Europäischen
Bauprodukten-Richtlinie
Nach der neuen Inhaltsangabe für den neuen Anhang ZA wird ein neuer Titel Literaturhinweise eingefügt.
2 Abschnitt 2 Normative Verweisungen
Folgendes ist zu ergänzen:
EN 50165, Elektrische Ausrüstung von nicht-elektrischen Geräten für den Hausgebrauch und ähnliche
Zwecke. Sicherheitsanforderungen
ISO 2859 (alle Teile), Sampling procedures for inspection by attributes"
3 Abschnitt 3 Begriffe
Absatz 3.28 ist zu streichen und durch folgenden zu ersetzen:
3.28
Verbindungsstück
Kanal, durch den die Abgase vom Abgasstutzen der Feuerstätte in den Schornsteinzug geführt werden
4 Abschnitt 4 Werkstoffe, Auslegung und Ausführung
4.1 Dokumentation zur Fertigung
Nach dem ersten Absatz ist folgender Text zu ergänzen:
Die Kenndaten und Merkmale, die bei der Entscheidungsfindung hinsichtlich der zur Erstprüfung (siehe 9.2.1)
oder – falls Änderungen an einer Feuerstätte vorgenommen wurden – zur Folgeprüfung (siehe 9.2.2.)
einzuschickenden Feuerstättengruppe oder –reihe berücksichtigt werden, müssen festgehalten werden. Eine
Kopie der bei der Entscheidungsfindung berücksichtigten Kenndaten und Merkmale wird in die Dokumentation
zur Fertigung für jede Feuerstätte übernommen.
5 Abschnitt 5 Anforderungen an die Sicherheit
5.4 Sicherheitsprüfung bei natürlichem Förderdruck
Der erste Satz in Abschnitt 5.4 ist zu streichen und durch folgenden Text zu ersetzen:
Wenn der Hersteller angibt, dass das Gerät für Dauerbetrieb und speziell für die Installation von mehren
Geräten an einem Abgassystem geeignet ist z.B. mehrere Geräte an einem Schornstein, dann ist das Gerät
nach A.4.15 zu prüfen. Bei der Prüfung nach A.4.15 darf entweder der Förderdruck während der
Versuchsdauer nicht weniger als 3 Pa betragen oder - falls der Förderdruck 3 Pa unterschreitet – die
Kohlenstoffmonoxidgesamtmenge im Abgas berechnet im Normzustand nach A.6.2.8 während eines
Zeitraums von weiteren 10 h nach Unterschreiten von 3 Pa nicht mehr als 250 dm³ betragen.
Neuer Abschnitt 5.7
Folgender neuer Absatz 5.7 zur elektrischen Sicherheit ist zu ergänzen:
5.7 Elektrische Sicherheit
Die Feuerstätte muss den elektrischen Sicherheitsanforderungen von EN 50165 entsprechen, falls netzbetrie-
bene elektrische Ausrüstung Bestandteil der Feuerstätte ist.
6 Abschnitt 6 Anforderungen an das Leistungsvermögen
6.3 Grenzwerte für Kohlenstoffmonoxidemissionen
Der Abschnitt 6.3 mit dem Titel, Texten, zugehörigen Anmerkungen und Tabelle 5 sind zu streichen und durch
folgenden Abschnitt zu ersetzen:
6.3 Kohlenstoffmonexidemission
Bei der Prüfung der Nennwärmeleistung nach A.4.9 darf die mittlere Kohlenstoffmonoxid-Konzentration,
bezogen auf 13 % O -Gehalt im Abgas nicht größer als der vom Hersteller angegebene Wert, bzw. 1 % nicht
überschreiten.
In einigen Ländern fordern nationale Gesetze Grenzwerte für Kohlenstoffmonoxid-Emission bei Schwachlast;
in diesen Fällen muss die Kohlenstoffmonoxid-Emission bei der Prüfung der Nennwärmeleistung nach A.4.12
gemessen werden, falls diese Geräte in diesem Land verkauft werden.
6.4 Wirkungsgrad bei Nennwärmeleistung
Der Abschnitt 6.4 mit dem Titel, Texten, zugehörigen Anmerkungen und Tabelle 6 sind zu streichen und durch
folgenden Abschnitt zu ersetzen:
6.4 Wirkungsgrad
Bei der Prüfung nach A.4.9 darf der Gesamtwirkungsgrad – ermittelt aus mindestens zwei Abbrandperioden –
den vom Hersteller genannten Wert nicht unterschreiten und nicht geringer sein als 60 %.
In einigen Ländern fordern nationale Gesetze Grenzwerte für Wirkungsgrade bei Schwachlast; in diesen
Fällen muss der Mindestwirkungsgrad bei der Prüfung der Schwachlast nach A.4.12 bestimmt werden, falls
die Feuerstätten in diesem Land verkauft werden.
6.5 Brenndauer bei Nennwärmeleistung
Folgender neuer dritter Abschnitt in Abschnitt 6.5 einzufügen:
Die Aufgabe für die Nennwärmeleistung errechnet sich aus der Brenndauer, dem Mindestwirkungsgrad und
dem Heizwert des Brennstoffs nach A.4.2.
7 Abschnitt 7 Anleitungen für die Feuerstätte
7.2 Aufstellanleitung
Der 12. Spielstrich von Abschnitt 7.2 ist zu streichen und durch folgenden zu ersetzen:
 Abgasmassenstrom in g/s bei Nennwärmeleistung bestimmen nationale oder örtliche Vorschriften (oder
alternativ Nennwärmeleistung, Wirkungsgrad und mittlerer CO -Gehalt bei Nennwärmeleistung für alle
geprüften Brennstoffe).
8 Abschnitt 8 Kennzeichnung
Spiegelstrich 3 aus Abschnitt 8 ist zu streichen und durch folgenden zu ersetzen:
 die gemessene CO-Konzentration bei 13 % O -Gehalt;
 Bestimmung des Grätewirkungsgrad bei Nennwärmeleistung;
 die Modellnummer und/oder Typbezeichnung zur Identifizierung;
9 Neuer Abschnitt 9
Der folgende neue Abschnitt 9 ist zu ergänzen:
9 Konformitätsprüfung
9.1 Allgemeines
Die Übereinstimmung eines Herdes mit den Bestimmungen dieser Norm sowie mit den vorgegebenen Werten
(inklusive Klassen) muss nachgewiesen werden durch:
 Typprüfung
 werkseigene Produktionskontrolle durch den Hersteller, einschl. Produktprüfung
Feuerstätten können für Prüfzwecke in Gruppen eingeteilt werden, wenn davon auszugehen ist, dass das
ausgewählte Leistungsmerkmal oder die ausgewählten Leistungsmerkmale in den Tabellen 9 und 10 allen
Feuerstätten dieser Gruppe gemeinsam sind.
9.2 Typprüfung
9.2.1 Erstprüfung
Die Erstprüfung erfolgt zum Nachweis der Konformität mit dieser Norm. Befindet sich eine Feuerstätte bereits
in Produktion, so wird die zu prüfende Feuerstätte zufällig ausgewählt und ist repräsentativ für die gesamte
Produktion, und der Hersteller gibt eine diesbezügliche schriftliche Erklärung ab.
Im Falle eines Prototyps ist die geprüfte Feuerstätte ein Modell, das repräsentativ für die geplante zukünftige
Produktion ist, und der Hersteller bestätigt in einer schriftlichen Erklärung, dass dies der Fall ist. Wenn die
Feuerstätte in die Produktion geht, muss die produzierte Feuerstätte bezüglich ihrer Abmessungen und
Konstruktion untersucht werden um festzustellen, dass diese mit dem typgeprüften Original-Modell
übereinstimmt. Wenn die Abmaße der Feuerstätte aus der Produktion um mehr als 1 % oder ± 3 mm (was
auch immer die geringere Abweichung ist) von dem Prototypen bezüglich des Feuerraums oder eines
anderen Abmaßes, was bezüglich Sicherheit und Leistung der Feuerstätte (besonders im Hinblick auf die
Eigenschaften der Tabellen 9 und 10) abweichen, dann muss die Feuerstätte aus der Produktion einer
weiteren Typprüfung, wie in 9.2.2 beschrieben, unterzogen werden.
Ähnlich wenn andere Werkstoffe verwendet werden, die normwidrig die Leistungseigenschaften der
Feuerstätte verändern im Hinblick auf die Sicherheit und/oder in der Erfüllung der Leistungskriterien aus
Tabelle 10, muss die Feuerstätte aus der Produktion einer weiteren Typprüfung nach 9.2.2 unterzogen
werden. Diese Anforderung bezüglich der Nachprüfung ist anzuwenden, wenn während der anschließenden
Produktion oder zu Beginn einer neuen Produktion eine Änderung der Abmaße und/oder der Werkstoffe
durchgeführt wird. Um dies sicherzustellen, muss eine Prüfung der Abmaße und Werkstoffe an einer in der
Produktion befindlichen Feuerstätte in einem Zeitraum von nicht mehr als 3 Jahren durchgeführt werden, um
Übereinstimmung festzustellen.
Zuvor bereits entsprechend den Bestimmungen dieser Norm durchgeführte Prüfungen (gleiches Produkt,
gleiche(s) Merkmal(e), Prüfverfahren, Probenahmeverfahren, System der Konformitätsbescheinigungen usw.)
müssen berücksichtigt werden, um Konformität abschätzen zu können.
Bei einer Feuerstättengruppe oder –reihe ist es zulässig, nur ausgewählte Feuerstätten dieser Gruppe oder
Reihe zu prüfen und bei den übrigen nur ausgewählte Konstruktions- und Leistungsmerkmale zu überprüfen,
wenn klar entschieden wird, dass die Feuerstätten einer Feuergruppe oder –reihe angehören.
Für die erste Typprüfung muss eine zumindest ausreichende Anzahl von Feuerstätten von einer Gruppe oder
Reihe ausgewählt werden, die ausreichend die Gruppe oder Reihe repräsentieren. Die ausgewählten
Feuerstätten müssen einer kompletten Prüfung unterzogen werden, um ihre Übereinstimmung mit dieser
Norm in allen Eigenschaften der Konstruktion und des Leistungsvermögens sicherzustellen. Für die anderen
Feuerstätten dieser Gruppe oder Reihe, die nicht für eine umfassende Prüfung ausgewählt werden, ist es
zulässig, nur ausgewählte Konstruktions- und Leistungsmerkmale zu überprüfen, um ihre Übereinstimmung
mit den Anforderungen dieser Norm sicherzustellen und/oder um sicherzustellen, dass sie dasselbe leisten
wie die gänzlich typgeprüfte Feuerstätte einer Reihe oder Gruppe.
Wenn Feuerstätten für die Typprüfung aus einer Reihe bezüglich ihrer Nennwärmeleistungen ausgewählt
werden, die die Reihe darstellen, dann müssen genügend Feuerstätten aus der Reihe für die Prüfung gewählt
werden, dass das Verhältnis der Nennwärmeleistungen zwischen den einzelnen Feuerstätten von 1,6: 1 nicht
überschritten wird.
Bei der Entscheidung, ob die Feuerstätten einer Gruppe oder Reihe angehören, müssen die Konstruktions-
und Leistungsmerkmale jeder Feuerstätte entsprechend den Merkmalen in den Tabellen 9 und 10 gebührend
berücksichtigt werden. Das Merkmalverzeichnis in den Tabellen 9 und 10 ist nicht endgültig, und die
Berücksichtigung anderer Aspekte kann bei diesem Urteil erforderlich sein. Wenn eine Gruppe von
Feuerstätten mit gleichem Brennraum und gleicher Wärmeleistung unterschiedliche Mantelhauben und
metallische Verkleidungen in Größe und Werkstoff (z. B. wo heiße Oberflächen näher an brennbaren
Bauteilen sind oder wo es eine Abänderung von niedriger zur höheren Wärmeleitfähigkeit oder Strahlung gibt)
muss zumindest eine Feuerstätte mit den schlechtest möglichen Eigenschaften ausgewählt werden, die die
Sicherheit der Reihe bezüglich Oberfläche
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.