CEN/TC 295/WG 1 - Cookers
Standardisation concerning appliances fired by wood logs, briquettes and mineral fuels only, excluding slow heat release appliances, tiled stoves and sauna stoves, with or without: - assistance fan; - regulation; - partial accumulation; - boiler.
Cookers
Standardisation concerning appliances fired by wood logs, briquettes and mineral fuels only, excluding slow heat release appliances, tiled stoves and sauna stoves, with or without: - assistance fan; - regulation; - partial accumulation; - boiler.
General Information
This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
- wood logs;
- compressed untreated wood;
- wood pellets;
- lignite briquettes;
- solid mineral fuels;
- peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
- appliances for hot water only production and heat output < 5 kW;
- automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-1 of EN 16510 is applicable to freestanding or inset roomheaters fired by solid fuel, without functional modification that operate with fire doors either as closed only or as closed or open.
The appliances covered by this Part 2-1 of EN 16510 provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions:
- wood logs;
- compressed untreated wood;
- wood pellets;
- solid minearal fuels;
- peat briquettes.
This Part 2-1 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This Part 2-1 of EN 16510 is to be used in conjunction with EN 16510 1 of which it is an integral part.
- Draft24 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-4 of EN 16510 is applicable to hand and automatically fired residential independent boilers having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation.
The appliances covered by this Part 2-4 of EN 16510 may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions: .
- wood logs
- compressed untreated wood
- wood pellets
- solid minearal fuels
- peat briquettes.
This Part 2-4 of EN 16510 is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This Part 2-4 of EN 16510 is also not applicable to the design and construction of automatic stoking devices.
This Part 2-4 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Draft29 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-3 of EN 16510 is applicable to hand fired residential cookers whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn one or more types of the following solid fuels in accordance with the appliance manufacturer’s instructions:
- wood logs
- compressed untreated wood
- wood pellets
- solid mineral fuels
- peat briquettes.
This Part 2-3 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fired.
This Part 2-3 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Draft37 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2-2 of EN 16510 is applicable to hand fed solid fuel fired inset appliances, with or without functional modification, that operate without firedoors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel. The surround of these appliances are integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure. These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating.
These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions.
This Part 2-2 of EN 16510 also covers ‘Kachelofen’ and ‘Putzofen’ inset appliances, having nominal heat outputs up to 15 kW prEN 16510-1
This Part 2-2 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this Part 2-2 of EN 16510.
This Part 2-2 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
- Draft35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission), instructions and marking together with associated test methods for type testing, residential open fires and inset appliances fired by solid fuel.
This standard is applicable to hand fired appliances which are listed under categories 1b, 1c, 2b, 2c, 3a, 3b and 3c of Table 1. The surround of the appliances is integrated with the building with the exception of free-standing appliances and inset appliances which are installed into a fireplace recess or enclosure.
This standard is not applicable to appliances with fan assisted combustion air.
These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. They may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this standard.
- Draft104 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, performance (efficiency and emission), safety, instructions and marking together with associated test methods and test fuels for type testing residential independent boilers fired by solid fuel.
This standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn either solid mineral fuels, peat briquettes or natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions.
This standard is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This standard is also not applicable to the design and construction of automatic stoking devices.
- Draft82 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission), instructions and marking together with associated test methods and test fuels for type testing residential coking apliances fired by solid fuel.
This standard is applicable to hand fired appliances whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler they also provide domestic hot water and/or central heating. These appliances may burn either solid mineral fuels, peat briquettes or natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions.
This standard is not applicable to hopper fed or mechanically fired appliances or those appliances having fan assisted combustion air.
- Draft98 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Addition of NOTE in 6.3
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - Addition of NOTE in 6.7
- Corrigendum2 pagesEnglish and German languagesale 10% offe-Library read for1 day
TC - Addition of NOTE in 6.3.2
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.1.1
- Corrigendum3 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.1.1
- Corrigendum3 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.1.1
- Corrigendum2 pagesEnglish and German languagesale 10% offe-Library read for1 day
This Standard is applicable to hand fired appliances whose primary function is to provide heat into the space in which they are installed and which are listed under categories 1b, 1c, 2b, 2c, 3a, 3b and 3c of table 1 of prEN 13229. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occurring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent product or be multi-fuel in accordance with the appliance manufacturer's instructions. The surround of the appliance is integrated with the building with the exception of free-standing appliances and inset appliances which are installed into a fireplace recess or enclosure. This standard is not applicable to appliances having fan assisted combustion air. Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplied for installation inti an existing heat resistant, insulated firebox are not covered by this standard.
- Amendment23 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment23 pagesGerman languagesale 10% offe-Library read for1 day
This Standard is applicable to hand fired appliances whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occuring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent products or be multi-fuel in accordance with the appliance maufacturer's instructions. This standard is not applicable to hopper fed or mechanically fired appliances or those appliances having fan assisted combustion air.
- Amendment22 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment22 pagesGerman languagesale 10% offe-Library read for1 day
The standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn naturally occurring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent product or be multi-fuel in accordance with the appliance manufacturer's instructions.
- Amendment20 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment22 pagesGerman languagesale 10% offe-Library read for1 day
The amendment to be drafted to cover Kachelofen and Putzofen appliances.
- Amendment22 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment21 pagesGerman languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission), instructions and marking together with associated test methods and test fuels for type testing residential cooking appliances fired by solid fuel.
This Standard is applicable to hand fired appliances whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to hopper fed or mechanically fired appliances or those appliances having fan assisted combustion air.
- Standard73 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard59 pagesGerman languagesale 10% offe-Library read for1 day
- Standard – translation81 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission), instructions and marking together with associated test methods for type testing, residential open fires and inset appliances fired by solid fuel.
This standard is applicable to hand fired appliances which are listed under categories 1b, 1c, 2b, 2c, 3a, 3b and 3c of Table 1. The surround of the appliances is integrated with the building with the exception of free-standing appliances and inset appliances which are installed into a fireplace recess or enclosure.
This standard is not applicable to appliances with fan assisted combustion air.
These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. They may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this standard.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard63 pagesGerman languagesale 10% offe-Library read for1 day
- Standard – translation84 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) instructions and marking together with associated test methods and test fuels for type testing residential roomheaters fired by solid fuel.
This Standard is applicable to non-mechanically fired appliances which are listed under categories 1a and 2a of Table 1. These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to appliances with fan assisted combustion air.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements relating to the design, manufacture, construction, performance (efficiency and emission), safety, instructions and marking together with associated test methods and test fuels for type testing residential independent boilers fired by solid fuel.
This standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn either solid mineral fuels, peat briquettes or natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This standard is also not applicable to the design and construction of automatic stoking devices.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard48 pagesGerman languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.8
- Corrigendum2 pagesEnglish and German languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.9
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - Modification to A.6.2.9
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - A.6.2.7.1, replace Equation 18 in E, F and D
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC - A.6.2.7.1, replace Equation 17 in E and D
- Corrigendum2 pagesEnglish and German languagesale 10% offe-Library read for1 day
TC - A.6.2.7.1, replace Equation 17 in E, F and D
- Corrigendum2 pagesEnglish, French and German languagesale 10% offe-Library read for1 day