This document specifies procedures for assessment and verification of constancy of performance (AVCP).
This document is applicable to roomheaters, inset appliances and cookers which can be fired batchwise in fuel baskets for wood pellets (freestanding manually fuelled intermittent burning appliances).
This document is applicable to appliances with fully integrated baskets for wood pellets which are integral component of the appliance. If the appliance is to be fired with wood logs or compressed untreated wood (wood briquettes), the configuration of the combustion chamber can be changed according to the instructions. Different fuels cannot be operated at the same time and they can be tested separately according the relevant part of EN 16510-2-x.
The intended use of the appliances is space heating in residential buildings and can be cooking (when tested accordingly).
These appliances can be supplied either as an assembled appliance or as a predesigned unit consisting of prefabricated components designed to be built on site in accordance with the specified assembly instructions.
They only operate with the firedoors closed.
This document is not applicable to:
- mechanically fed appliances;
- appliances with fan assisted combustion air;
- appliances with boiler.
Häusliche Feuerstätten für feste Brennstoffe - Teil 2-9: Geräte, die chargenweise mit Holzpellets in Brennstoffkörben befeuert werden
Dieses Dokument legt das Verfahren für die Bewertung und Überprüfung der Leistungsbeständigkeit (en: assessment and verification of constancy of performance, AVCP) fest.
Dieses Dokument ist anzuwenden für Raumheizer, Einsätze und Herde, die chargenweise mit Holzpellets in Brennstoffkörben befeuert werden (freistehende, manuell beschickte Zeitbrand-Feuerstätten).
Dieses Dokument ist anzuwenden für Geräte mit vollständig integrierten Körben für Holzpellets, die einen integralen Bestandteil der Feuerstätte darstellen. Wenn das Gerät mit Scheitholz oder verdichtetem, unbehandeltem Holz (Holzbriketts) betrieben werden soll, kann die Ausführung des Brennraums nach den Anleitungen geändert werden. Unterschiedliche Brennstoffe dürfen nicht gleichzeitig betrieben werden; sie können jedoch jeweils separat nach dem relevanten Teil von EN 16510-2-x geprüft werden.
Der Verwendungszweck der Geräte ist Raumheizung in Wohngebäuden und kann (bei entsprechender Prüfung) das Kochen sein.
Diese Feuerstätten können entweder als fertig montiertes Gerät geliefert werden oder als vorgeplante Einheit aus vorgefertigten Komponenten, die vor Ort gemäß den angegebenen Montageanleitungen aufgebaut werden.
Sie werden nur mit geschlossenen Feuerraumtüren betrieben.
Dieses Dokument ist nicht anzuwenden für:
- mechanisch beschickte Geräte;
- Geräte mit Verbrennungsluftgebläse;
- wasserführende Geräte.
Appareils de chauffage domestiques à combustible solide - Partie 2-9: Appareils alimentés par charge de granulés en panier
Le présent document spécifie des modes opératoires pour l’évaluation et la vérification de la constance des performances (EVCP).
Il s’applique aux poêles, inserts et cuisinières alimentés en charge par lot de granulés en panier (appareils de chauffage indépendants à combustion intermittente alimentés manuellement).
Le présent document s’applique aux appareils qui disposent de paniers destinés au chargement des granulés de bois, qui font partie intégrante de l’appareil. Si l’appareil est destiné à être alimenté en bûches de bois ou en bois compressé non traité (briquettes de bois), la configuration de la chambre de combustion peut être modifiée, conformément aux instructions. Il n’est pas possible d’utiliser simultanément différents combustibles, et ceux-ci peuvent être soumis à essai séparément, conformément à la partie pertinente de l’EN 16510-2-x.
L’usage prévu des appareils est le chauffage des locaux dans les bâtiments résidentiels et éventuellement la cuisson (cet usage prévu étant alors soumis aux essais correspondants).
Ces appareils peuvent être fournis sous la forme soit d’un appareil assemblé, soit d’une unité conçue au préalable, constituée d’éléments préfabriqués, destinés à être montés sur le site conformément aux instructions d’assemblage spécifiées.
Ils ne fonctionnent qu’avec les portes foyères fermées.
Le présent document ne s’applique pas:
- aux appareils à alimentation mécanique;
- aux appareils dont l’air de combustion est assisté par un ventilateur;
- aux appareils avec bouilleur.
Grelne naprave na trdna goriva za stanovanjske stavbe - 2-9. del: Naprave za serijsko kurjenje lesnih peletov v košarah za gorivo
General Information
- Status
- Not Published
- Publication Date
- 16-Sep-2027
- Technical Committee
- CEN/TC 295 - Residential solid fuel burning appliances
- Drafting Committee
- CEN/TC 295/WG 1 - Cookers
- Current Stage
- 4020 - Submission to enquiry - Enquiry
- Start Date
- 29-Jan-2026
- Due Date
- 01-May-2026
- Completion Date
- 29-Jan-2026
Overview
prEN 16510-2-9:2026 is a draft European Standard developed by CEN that specifies requirements and procedures for the assessment and verification of constancy of performance (AVCP) for residential solid fuel burning appliances. This part focuses especially on appliances that are fired batchwise with wood pellets in fuel baskets, such as roomheaters, inset appliances, and cookers. These are manually fueled, intermittent burning appliances intended primarily for space heating and, in some configurations, also cooking applications in residential buildings.
The standard applies to appliances only when operated with closed firedoors and with fully integrated wood pellet baskets that are an integral appliance component. The combustion chamber may be reconfigured, as per manufacturer’s instructions, to allow alternate use with wood logs or briquettes, but these fuels are not used simultaneously.
Key Topics
- Assessment and Verification of Constancy of Performance (AVCP): Defines procedures for verifying that appliances meet consistent performance criteria over time.
- Emission Limits: Establishes requirements for carbon monoxide (CO), nitrogen oxides (NOx), organic gaseous compounds (OGC), and particulate matter (PM) emissions at various heat outputs.
- Efficiency and Performance: Specifies methods to measure space and water heat output, minimum efficiencies, and energy efficiency classifications.
- Safety and Installation: Covers safety in everyday use, installation proximity to combustible materials, flue gas temperatures, and minimum draught requirements.
- Environmental Sustainability: Refers to life cycle assessment following EN 15804, addressing global warming potential and other sustainability metrics.
- Descriptive Features: Stipulates information to support correct appliance selection and installation, such as compatibility with ventilation systems and appliance mass for building statics.
- Scope Limitations: Excludes mechanically fed appliances, those with fan-assisted combustion air, or integrated boilers from its scope.
Applications
Appliances covered by prEN 16510-2-9 are intended for:
- Space Heating: Heating residential spaces using wood pellets loaded in integrated baskets.
- Cooking: When tested and designed for this use, these appliances can also serve as residential cookers.
- Flexible Fuel Use: While optimized for pellet burning, many models can be reconfigured for wood logs or briquettes, with performance verified separately per fuel.
- Site-Specific Installation: Appliances may be supplied fully assembled or as prefabricated components for on-site assembly, following detailed installation instructions.
- Building Integration: The standard supports architects, builders, and installation professionals by ensuring compatibility with standard building features, including ventilation and structural support.
Related Standards
prEN 16510-2-9 works in conjunction with related European standards to create a consistent regulatory environment for solid fuel appliances:
- EN 16510-1:2022 - General requirements and test methods for residential solid fuel burning appliances. Acts as the foundational standard referenced throughout Part 2-9.
- EN 15804:2012+A2:2019 - Provides rules for developing Environmental Product Declarations (EPDs), used here for environmental sustainability assessments.
- EN 16510-2 series - Other parts of EN 16510-2 cover roomheaters, inset appliances, slow heat release stoves, mechanically fed pellet stoves, and combination or gravimetric appliances.
- National Building Codes and CEN/CENELEC Internal Regulations - These ensure consistent application of this draft standard across European countries.
prEN 16510-2-9 supports improved safety, energy efficiency, and sustainability in residential heating, ensuring that pellet-fired appliances contribute positively to modern, low-emission home environments. By complying with this standard, manufacturers, installers, and homeowners benefit from robust product performance, regulatory confidence, and environmental consideration.
Frequently Asked Questions
prEN 16510-2-9 is a draft published by the European Committee for Standardization (CEN). Its full title is "Residential solid fuel burning appliances - Part 2-9: Appliances fired batchwise with wood pellets in fuel baskets". This standard covers: This document specifies procedures for assessment and verification of constancy of performance (AVCP). This document is applicable to roomheaters, inset appliances and cookers which can be fired batchwise in fuel baskets for wood pellets (freestanding manually fuelled intermittent burning appliances). This document is applicable to appliances with fully integrated baskets for wood pellets which are integral component of the appliance. If the appliance is to be fired with wood logs or compressed untreated wood (wood briquettes), the configuration of the combustion chamber can be changed according to the instructions. Different fuels cannot be operated at the same time and they can be tested separately according the relevant part of EN 16510-2-x. The intended use of the appliances is space heating in residential buildings and can be cooking (when tested accordingly). These appliances can be supplied either as an assembled appliance or as a predesigned unit consisting of prefabricated components designed to be built on site in accordance with the specified assembly instructions. They only operate with the firedoors closed. This document is not applicable to: - mechanically fed appliances; - appliances with fan assisted combustion air; - appliances with boiler.
This document specifies procedures for assessment and verification of constancy of performance (AVCP). This document is applicable to roomheaters, inset appliances and cookers which can be fired batchwise in fuel baskets for wood pellets (freestanding manually fuelled intermittent burning appliances). This document is applicable to appliances with fully integrated baskets for wood pellets which are integral component of the appliance. If the appliance is to be fired with wood logs or compressed untreated wood (wood briquettes), the configuration of the combustion chamber can be changed according to the instructions. Different fuels cannot be operated at the same time and they can be tested separately according the relevant part of EN 16510-2-x. The intended use of the appliances is space heating in residential buildings and can be cooking (when tested accordingly). These appliances can be supplied either as an assembled appliance or as a predesigned unit consisting of prefabricated components designed to be built on site in accordance with the specified assembly instructions. They only operate with the firedoors closed. This document is not applicable to: - mechanically fed appliances; - appliances with fan assisted combustion air; - appliances with boiler.
prEN 16510-2-9 is classified under the following ICS (International Classification for Standards) categories: 97.100.30 - Solid fuel heaters. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN 16510-2-9 is associated with the following European legislation: EU Directives/Regulations: 305/2011. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN 16510-2-9 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2026
Grelne naprave na trdna goriva za stanovanjske stavbe - 2-9. del: Naprave za
serijsko kurjenje lesnih peletov v košarah za gorivo
Residential solid fuel burning appliances - Part 2-9: Appliances fired batchwise with
wood pellets in fuel baskets
Häusliche Feuerstätten für feste Brennstoffe - Teil 2-9: Geräte, die chargenweise mit
Holzpellets in Brennstoffkörben befeuert werden
Appareils de chauffage domestiques à combustible solide - Partie 2-9: Appareils
alimentés par charge de granulés en panier
Ta slovenski standard je istoveten z: prEN 16510-2-9
ICS:
97.100.30 Grelniki na trdo gorivo Solid fuel heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2026
ICS 97.100.30
English Version
Residential solid fuel burning appliances - Part 2-9:
Appliances fired batchwise with wood pellets in fuel
baskets
Appareils de chauffage domestiques à combustible Häusliche Feuerstätten für feste Brennstoffe - Teil 2-9:
solide - Partie 2-9 : appareils alimentés par charge de Geräte, die chargenweise mit Holzpellets in
granulé en panier Brennstoffkörben befeuert werden
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 295.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16510-2-9:2026 E
worldwide for CEN national Members.
prEN 1650-2-9:2026 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Characteristics . 6
4.1 Load bearing capacity . 6
4.2 Subclause title . 6
4.3 Carbon monoxide emission (CO) . 7
4.4 Nitrogen oxides (NO ) emissions . 8
x
4.5 Emission of organic gaseous compounds (OGC) . 8
4.6 Particulate matter (PM) emissions . 8
4.7 Safety and accessibility in use . 9
4.7.1 General. 9
4.7.2 Flue gas outlet temperature at nominal heat output . 9
4.7.3 Flue gas outlet temperature at part load heat output . 9
4.7.4 Minimum flue draught at nominal heat output . 9
4.7.5 Minimum flue draught at part load heat output . 9
4.7.6 Flue gas mass flow at nominal heat output . 10
4.7.7 Flue gas mass flow at part load heat output . 10
4.7.8 Fire safety of installation to the chimney . 10
4.8 Energy economy and heat retention . 10
4.8.1 Space heat output at nominal heat output . 10
4.8.2 Water heat output, if existing at nominal heat output . 11
4.8.3 Efficiency at nominal heat output . 11
4.8.4 Space heat output at part load heat output . 11
4.8.5 Water heat output, if existing at part load heat output . 11
4.8.6 Efficiency at part load heat output . 11
4.8.7 Seasonal space heating efficiency at appliance’s nominal heat output . 11
4.8.8 Energy efficiency . 12
4.8.9 Electric power consumption at nominal heat output, if existing . 13
4.8.10 Electric power consumption at part load heat output, if existing . 13
4.8.11 Standby mode power consumption, if existing . 13
4.9 Environmental sustainability . 13
5 Descriptive features . 15
5.1 Data for potential use with room ventilation systems: type of appliance (in relation to
its tightness to the room) . 15
5.2 Data for the building's statics: appliance's mass . 15
5.3 Materials and construction elements . 15
5.3.1 General. 15
5.3.2 General stresses . 15
5.3.3 Pellet basket compartment . 16
5.4 Risk of burning fuel falling out. 16
5.5 Temperature rise in the fuel storage, if any . 16
5.6 Temperature rise of the operating components . 16
5.7 Spillage of flue gases into the room . 16
5.7.1 Possible spillage of CO, if relevant for the fuel type . 16
5.8 Cleanability . 16
5.8.1 Heating surfaces . 16
5.8.2 Flueways . 16
5.8.3 Ashpan . 16
5.8.4 bottomgrate . 16
5.8.5 Pellet basket bottomgrid . 16
5.8.6 Damper . 17
5.8.7 Fan-cut-out-device . 17
6 Assessment and verification of constancy of performance - AVCP . 17
6.1 General . 17
6.2 Assessment of performance . 17
6.2.1 General . 17
6.2.2 Test samples, testing and compliance criteria . 18
6.3 Verification of constancy of performance. 19
6.3.1 Factory production control (FPC) . 19
Annex A (normative) Test methods . 24
Annex IA (informative) Operating principle of the batchwise basket pellet-fed roomheater
................................................................................................................................................................... 30
prEN 1650-2-9:2026 (E)
European foreword
This document (prEN 16510-2-9:2026) has been prepared by Technical Committee CEN/TC 295
“Residential solid fuel burning appliances”, the secretariat of which is held by BSI.
This document is currently submitted to CEN Enquiry.
The structure of EN 16510, Residential solid fuel burning appliances, is as follows:
— Part 1: General requirements and test methods;
— Part 2-1: Roomheaters;
— Part 2-2: Inset appliances including open fires;
— Part 2-3: Cookers;
— Part 2-4: Independent boilers — Nominal heat output up to 50 kW;
— Part 2-5: Slow heat release appliances;
— Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers;
— Part 2-7: Combination appliances fired by wood logs and pellets;
— Part 2-8: Gravimetrically pellet-fed roomheaters (under development);
— Part 2-9: Appliances fired batchwise with wood pellets in fuel baskets (This document);
— Part 2-10: Multi-firing sauna stoves fired by natural wood logs - Requirements and test methods.
Other sections of Part 2 will be added to cover residential solid fuel burning appliances not included in
parts 2-1 to 2-10.
Subclauses and Figures which are additional to those in EN 16510-1:2022 are numbered starting with
901. Annexes which are additional to those in EN 16510-1:2022 are numbered starting with IA.
1 Scope
This document specifies procedures for assessment and verification of constancy of performance (AVCP).
This document is applicable to roomheaters, inset appliances and cookers which can be fired batchwise
in fuel baskets for wood pellets (freestanding manually fuelled intermittent burning appliances).
This document is applicable to appliances with fully integrated baskets for wood pellets which are
integral component of the appliance. If the appliance is to be fired with wood logs or compressed
untreated wood (wood briquettes), the configuration of the combustion chamber can be changed
according to the instructions. Different fuels cannot be operated at the same time and they can be tested
separately according the relevant part of EN 16510-2-x.
The intended use of the appliances is space heating in residential buildings and can be cooking (when
tested accordingly).
These appliances can be supplied either as an assembled appliance or as a predesigned unit consisting of
prefabricated components designed to be built on site in accordance with the specified assembly
instructions.
They only operate with the firedoors closed.
This document is not applicable to:
— mechanically fed appliances;
— appliances with fan assisted combustion air;
— appliances with boiler.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 15804:2012+A2:2019, Sustainability of construction works - Environmental product declarations - Core
rules for the product category of construction products
EN 16510-1:2022, Residential solid fuel burning appliances - Part 1: General requirements and test methods
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 16510-1:2022 apply with the
following additions.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.901
pellet basket
integral part, removable or not, of the appliance at the base of the combustion chamber which contains
the wood pellet batch load and carries the wood pellet gasification process through which combustion
air and/or combustion gases may be drawn
prEN 1650-2-9:2026 (E)
3.902
pellet basket bottomgrid
part of the basket at the base of it which supports the pellets through which the residue falls into the
ashpan or ashpit and through which combustion air and/or combustion gases may be drawn
3.903
pellet basket compartment
specific part in the appliance where the pellet basket is fit through which combustion air and/or
combustion gases may be drawn and that grants perfect pellet basket positioning
Note 1 to entry: Ashpan or ashpit can be part of this compartment.
4 Characteristics
4.1 Load bearing capacity
The performance of the appliance in relation to the ability to carry a chimney shall be determined in
accordance with EN 16510-1:2022, 4.6.
If for an appliance with an upper outlet the ability to carry a chimney is specified the value of the
maximum load shall be given in [kg] as an integer in accordance with EN 16510-1:2022, Table 22, no. 57
(m ).
chim
4.2 Subclause title
The performance of the appliance in relation to protection of combustible materials shall be determined
in accordance with EN 16510-1:2022, 5.6.
When tested in accordance with EN 16510-1:2022, 5.6, the protection measure(s) as specified in
accordance with Table 1 shall be given as minimum distance to combustible materials and if appropriate
as material type and thickness of protective insulation material.
The protection measures as specified shall be given in [mm] as an integer in accordance
, d , d , d , d , d , d , s).
with EN 16510-1:2022, Table 22, no. 33, 34, 35, 36, 37, 38, 39 and 41 (d
R S C P F L B
Table 1 — Protection of combustible materials
Protection measure Declared clearance distance to Protective
combustible material or insulation material
thickness of protective if any
insulation material
[mm]
Minimum distance to -
combustible materials - bottom
)
(d
B
Minimum distance to -
combustible materials – floor in
front (d )
F
Minimum distance to -
combustible materials – ceiling
(d )
C
Minimum distance to -
combustible materials – rear (d )
R
Minimum distance to -
combustible materials – side (d )
S
Minimum distance to -
combustible materials – side
)
radiation area (d
L
Minimum distance to adjacent -
combustible materials (e.g.
furniture) (d )
P
Protective insulation material (s)
4.3 Carbon monoxide emission (CO)
The performance of the appliance in relation to carbon monoxide emission at nominal heat output and at
part load heat output (if part load is specified) shall be determined in accordance with EN 16510-1:2022,
6.3.1 and 6.3.2.
The CO value if specified at nominal heat output and at part load heat output (if part load is specified)
shall be given in [mg/m ] as an integer in accordance with EN 16510-1:2022, Table 22, no. 17
(CO (13 % O )).
nom 2
When tested in accordance with EN 16510-1:2022, 6.3.2 the CO emission at nominal heat output shall
not exceed the threshold levels as given in Table 2.
There is no CO emission threshold at part load heat output, as there is no experience right now.
prEN 1650-2-9:2026 (E)
Table 2 — Threshold levels for CO emission at NHO
Appliance type Threshold level at 13 % O
closed fronted solid fuel local space heaters using
solid fuel other than compressed wood in the form 1250 mg/m
of pellets including cookers
closed fronted solid fuel local space heaters using
compressed wood in form of pellets including
750 mg/m
cookers
4.4 Nitrogen oxides (NO ) emissions
x
The performance of the appliance in relation to nitrogen oxides emissions at nominal heat output and at
part load heat output (if part load is specified) shall be determined in accordance with EN 16510-1:2022,
6.3.1 and 6.3.3.
The NO value if specified at nominal heat output and at part load heat output (if part load is specified)
x
shall be given in [mg/m ] as an integer in accordance with EN 16510-1:2022, Table 22, no. 20 (NO
xnom
(13 % O )).
When tested in accordance with EN 16510-1:2022, 6.3.3 the NO emissions at nominal heat output shall
x
not exceed the threshold levels as given in Table 3.
There is no NO emission threshold at part load heat output, as there is no experience right now.
x
Table 3 — Threshold levels for NO emissions at NHO (expressed as NO )
x 2
Appliance type Threshold level at 13 % O
closed fronted solid fuel local space heaters using
solid fuel other than compressed wood in the form 200 mg/m
of pellets including cookers
closed fronted solid fuel local space heaters using
compressed wood in form of pellets including
200 mg/m
cookers
4.5 Emission of organic gaseous compounds (OGC)
The performance of the appliance in relation to organic gaseous compounds emission at nominal heat
output and at part load heat output (if part load is specified) shall be determined in accordance with
EN 16510-1:2022, 6.3.1 and 6.3.4.
The OGC value if specified at nominal heat output and at part load heat output (if part load is specified)
shall be given in [mg/m ] as an integer in accordance with EN 16510-1:2022, Table 22, no. 23 (OGC
nom
(13 % O )).
When tested in accordance with EN 16510-1:2022, 6.3.4 the OGC emission at nominal heat output shall
comply with the combined OGC+PM threshold levels as given in Table 4.
There is no OGC+PM emission threshold at part load heat output, as there is no experience right now.
4.6 Particulate matter (PM) emissions
The performance of the appliance in relation to particulate matter emissions at nominal heat output and
at part load heat output (if part load is specified) shall be determined in accordance with
EN 16510-1:2022,6.3.1 and 6.3.5.
The particulate matter value if specified at nominal heat output and at part load heat output (if part load
is specified) shall be given in [mg/m ] as an integer in accordance with EN 16510-1:2022, Table 22,
no. 26 (PM (13 % O )).
nom 2
When tested in accordance with EN 16510-1:2022, 6.3.5 the particulate matter (PM) emissions at
nominal heat output shall comply with the combined OGC+PM threshold levels as given in Table 4.
There is no OGC+PM emission threshold at part load heat output, as there is no experience right now.
Table 4 — Threshold levels for OGC+PM at NHO emissions
Appliance type Threshold level at 13 % O
closed fronted solid fuel local space heaters using
solid fuel other than compressed wood in the form 135 mg/m
of pellets including cookers
closed fronted solid fuel local space heaters using
compressed wood in form of pellets including 80 mg/m
cookers
4.7 Safety and accessibility in use
4.7.1 General
The data for the installation to a chimney are to be evaluated at nominal heat output. Specific data are to
be evaluated at safety test heat output. Additional data are to be evaluated at part load heat output, if part
load is specified.
4.7.2 Flue gas outlet temperature at nominal heat output
The performance of the appliance in relation to flue gas outlet temperature at nominal heat output shall
be determined in accordance with EN 16510-1:2022, 6.2.1.
The value of the flue gas outlet temperature for the installation of the appliance to a chimney if specified
shall be given in [°C] as an integer in accordance with EN 16510-1:2022, Table 22, no. 47 (T ).
snom
4.7.3 Flue gas outlet temperature at part load heat output
The performance of the appliance in relation to flue gas outlet temperature at part load heat output
(if part load is specified) shall be determined in accordance with EN 16510-1:2022, 6.2.1.
The value of the flue gas outlet temperature at part load heat output (if part load is specified) for the
installation of the appliance to a chimney if specified shall be given in [°C] as an integer in accordance
).
with EN 16510-1:2022, Table 22, no. 48 (T
spart
4.7.4 Minimum flue draught at nominal heat output
The performance of the appliance in relation to the minimum flue draught at nominal heat output shall
be determined in accordance with EN 16510-1:2022, 6.5.
The value of the minimum flue draught if specified at nominal heat output for the installation of the
appliance to a chimney shall be given in [Pa] as an integer in accordance with EN 16510-1:2022, Table 22,
no. 29 (p ).
nom
4.7.5 Minimum flue draught at part load heat output
The performance of the appliance in relation to the minimum flue draught at part load heat output (if part
load is specified) shall be determined in accordance with EN 16510-1:2022, 6.5.
prEN 1650-2-9:2026 (E)
The minimum value of the flue draught if specified at part load heat output (if part load is specified) for
the installation of the appliance to a chimney shall be given in [Pa] as an integer in accordance with
EN 16510-1:2022, Table 22, no. 30 (p ).
part
4.7.6 Flue gas mass flow at nominal heat output
The performance of the appliance in relation to the flue gas mass flow at nominal heat output shall be
determined in accordance with EN 16510-1:2022, 6.12.
The flue gas mass flow value if specified at nominal heat output for the installation of the appliance to a
chimney shall be given in [g/s] with 1 decimal in accordance with EN 16510-1:2022, Table 22, no. 50
).
(ϕ
f,g nom
4.7.7 Flue gas mass flow at part load heat output
The performance of the appliance in relation to the flue gas mass flow at part load heat output (if part
load is specified) shall be determined in accordance with EN 16510-1:2022, 6.12.
The flue gas mass flow value if specified at part load heat output (if part load is specified) for the
installation of the appliance to a chimney shall be given in [g/s] with 1 decimal in accordance with
EN 16510-1:2022, Table 22, no. 51 (ϕ ).
f,g part
4.7.8 Fire safety of installation to the chimney
The performance of the appliance in relation to the flue gas temperature (mean value) at safety test shall
be determined firstly according to pellet in accordance with A.4.10.4.2 of this document and secondly if
declared according to wood log in accordance with EN 16510-1:2022, A.4.10.4. The flue gas temperature
shall be measured and the mean value of the cycle giving the highest mean value between e different fuels
is determined.
The data for installation of the appliance to a chimney with regards to the fire safety if specified shall be
given as the T of the chimney required in accordance with EN 16510-1:2022, 6.2.2 and
class
EN 16510-1:2022, Table 22, no. 49.
4.8 Energy economy and heat retention
4.8.1 Space heat output at nominal heat output
The performance of the appliance in relation to space heat output at nominal heat output shall be
determined in accordance with EN 16510-1:2022, 6.8.
The space heat output of the appliance if specified at nominal heat output shall be given in [kW] with 1
decimal in accordance with EN 16510-1:2022, Table 22, no. 2 (P ).
SHnom
For the proper performance of the appliance the following shall be considered as well for those essential
characteristics and descriptive features assessed during the nominal heat output test (A.4.7).
Additional devices, such as flue gas outlet components, components built-in the flue ways, combustion
air supply control devices, charging doors and ash-pit doors, flue bypass devices, internal flue gas
diverters, front fire bars and/or draught regulators for the safety or function of the appliance may be
present.
Some of these devices are optional, but if present their influence on the performance of the appliance
shall be checked in accordance with EN 16510-1:2022, 4.4.4, 4.4.6, 4.4.9, 4.4.11, 4.4.12, 4.4.13, 4.4.14,
and 4.4.16.
4.8.2 Water heat output, if existing at nominal heat output
The performance of the appliance in relation to water heat output (where appropriate) at nominal heat
output shall be determined in accordance with EN 16510-1:2022, 6.9.
The water heat output of the appliance if specified at nominal heat output shall be given in [kW] with
1 decimal in accordance with EN 16510-1:2022, Table 22, no. 3 (P ).
Wnom
4.8.3 Efficiency at nominal heat output
The performance of the appliance in relation to efficiency at nominal heat output shall be determined in
accordance with EN 16510-1:2022, 6.4 with the following modification.
Tests shall be carried out on 2 separates cycles with starting on cold condition as defined in A.4.7.3;
The efficiency of the appliance if specified at nominal heat output shall be given in [%] as an integer in
accordance with EN 16510-1:2022, Table 22, no. 13 (η ).
nom
4.8.4 Space heat output at part load heat output
The performance of the appliance in relation to space heat output at part load heat output (if part load is
specified) shall be determined in accordance with EN 16510-1:2022, 6.8.
The space heat output of the appliance if specified at part load heat output (if part load is specified shall
be given in [kW] with 1 decimal in accordance with EN 16510-1:2022, Table 22, no. 5 (P ).
SHpart
For the proper performance of the appliance the following shall be considered as well for those essential
characteristics and descriptive features assessed during the part load heat output test (A.4.8).
Additional devices, such as flue gas outlet components, components built-in the flue ways, combustion
air supply control devices, charging doors and ash-pit doors, flue bypass devices, internal flue gas
diverters, front fire bars and/or draught regulators for the safety or function of the appliance may be
present.
Some of these devices are optional, but if present their influence on the performance of the appliance
shall be considered in accordance with EN 16510-1:2022, 4.4.4, 4.4.6, 4.4.9, 4.4.11, 4.4.12, 4.4.13, 4.4.14,
and 4.4.16.
4.8.5 Water heat output, if existing at part load heat output
The performance of the appliance in relation to water heat output (where appropriate) at part load heat
output (if part load is specified) shall be determined in accordance with EN 16510-1:2022, 6.9.
The water heat output of the appliance if specified at part load heat output (if part load is specified) shall
be given in [kW] with 1 decimal in accordance with EN 16510-1:2022, Table 22, no. 6 (P ).
Wpart
4.8.6 Efficiency at part load heat output
The performance of the appliance in relation to efficiency at part load heat output (if part load is specified)
shall be determined in accordance with EN 16510-1:2022, 6.4.
The efficiency of the appliance if specified at part load heat output (if part load is specified) shall be given
in [%] as an integer in accordance with EN 16510-1:2022, Table 22, no. 14 (η ).
part
4.8.7 Seasonal space heating efficiency at appliance’s nominal heat output
The performance of the appliance in relation to seasonal space heating efficiency at nominal heat output
shall be determined in accordance with EN 16510-1:2022, 6.4.2.
The seasonal space heating efficiency of the appliance if specified at nominal heat output shall be given
in [%] as an integer in accordance with EN 16510-1:2022, Table 22, no. 15 (η ).
S
prEN 1650-2-9:2026 (E)
When tested in accordance with EN 16510-1:2022, 6.4.2 the seasonal space heating efficiency at nominal
heat output shall not underrun the threshold levels as given in Table 5.
Table 5 — Threshold level of seasonal space heating energy efficiency
Appliance type Threshold level
closed fronted solid fuel local space heaters using
solid fuel other than compressed wood in the form 65 %
of pellets including cookers
closed fronted solid fuel local space heaters using
compressed wood in form of pellets including 79 %
cookers
4.8.8 Energy efficiency
The performance of the appliance in relation to energy efficiency classification shall be determined in
accordance with EN 16510-1:2022, 6.4.3.
The energy efficiency classification of the appliance if specified shall be given in accordance with
EN 16510-1:2022, Table 22, no. 16 (EEI) and shall be determined as described in Table 6.
Table 6 — Energy efficiency classification based on the energy efficiency index (EEI)
Energy efficiency class Energy efficiency index (EEI)
A++ EEI ≥ 130
A+ 107 ≤ EEI < 130
A 88 ≤ EEI < 107
B 82 ≤ EEI < 88
C 77 ≤ EEI < 82
D 72 ≤ EEI < 77
E 62 ≤ EEI < 72
F 42 ≤ EEI < 62
G EEI < 42
4.8.9 Electric power consumption at nominal heat output, if existing
The performance of the appliance in relation to electric power consumption at nominal heat output shall
be determined in accordance with EN 16510-1:2022, 6.11.
The electric power consumption of the appliance if specified at nominal heat output shall be given in [kW]
with 3 decimals in accordance with EN 16510-1:2022, Table 22, no. 43 (el ).
max
4.8.10 Electric power consumption at part load heat output, if existing
The performance of the appliance in relation to electric power consumption at part load heat output
(if part load is specified) shall be determined in accordance with EN 16510-1:2022, 6.11.
The electric power consumption of the appliance if specified at part load heat output (if part load is
specified) shall be given in [kW] with 3 decimals in accordance with EN 16510-1:2022, Table 22,
no. 44 (el ).
min
4.8.11 Standby mode power consumption, if existing
The performance of the appliance in relation to standby mode power consumption at standby mode
(where appropriate) shall be determined in accordance with EN 16510-1:2022, 6.11.
The standby mode power consumption of the appliance if specified shall be given in [kW] with 3 decimals
in accordance with EN 16510-1:2022, Table 22, no. 42 (el ).
SB
4.9 Environmental sustainability
All relevant elements of the performance related to the whole life cycle of the appliance shall be identified
and enumerated on the basis on the information modules of EN 15804:2012+A2:2019.
The necessary environmental sustainability information shall be determined to enable the life cycle
analysis of the appliance concerned and the declaration of its performance in relation to the essential
characteristic environmental sustainability. This shall comprise in particular the definition of the
scenarios required for this complete period, including the reference service life, where appropriate.
The performance of the appliance in relation to the environmental sustainability shall be determined in
accordance with EN 16510-1:2022, Clause 8.
The environmental sustainability elements are given in Table 7.
prEN 1650-2-9:2026 (E)
Table 7 — Elements for the environmental sustainability
Environmental sustainability elements to be given in
Global Warming Potential total (GWP-total) kg CO equivalent
Global Warming Potential (GWP-fossil) kg CO equivalent
Global Warming Potential (GWP-biogenic) kg CO equivalent
Global Warming Potential land use and land use change (GWP-luluc) kg CO equivalent
Depletion potential of the stratospheric ozone layer (ODP) kg CFC 11 equivalent
+
Acidification potential, Accumulated Exceedance (AP)
mol H equivalent
Eutrophication potential, Fraction of nutrients reaching freshwater kg P equivalent
end compartment (EP-freshwater)
Eutrophication potential, Fraction of nutrients reaching freshwater kg N equivalent
end compartment (EP-marine)
Eutrophication potential, Accumulated Exceedance (EP-terrestrial) mol N equivalent
Formation potential of tropospheric ozone (POCP) kg NMVOC equivalent
Abiotic depletion potential for non-fossil resources (ADP-minerals kg Sb equivalent
and metals)
Abiotic depletion potential for fossil resources (ADP-fossil) MJ, net calorific value
Water (user) deprivation potential, deprivation-weighted water
m world equivalent deprived
consumption (WDP)
Potential incidence of disease due to PM emissions (PM) Disease incidence
• Potential Human exposure efficiency relative to U235 (IRP) kBq U235 eq.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) CTUe
Potential Comparative Toxic Unit for humans (HTP-c) CTUh
Potential Comparative Toxic Unit for humans (HTP-nc) CTUh
Potential soil quality index (SQP) dimensionless
Non-hazardous waste disposed kg
Radioactive waste disposed kg
Use of renewable primary energy excluding renewable primary MJ, net calorific value
energy resources used as raw materials
• Use of renewable primary energy resources used as raw materials MJ, net calorific value
Total use of renewable primary energy resources (primary energy MJ, net calorific value
and primary energy resources used as raw materials)
Use of non-renewable primary energy excluding non-renewable MJ, net calorific value
primary energy resources used as raw materials
Use of non-renewable primary energy resources used as raw MJ, net calorific value
materials
Total use of non-renewable primary energy resources (primary MJ, net calorific value
energy and primary energy resources used as raw materials)
Use of secondary material kg
Use of renewable secondary fuels MJ, net calorific value
Use of non-renewable secondary fuels MJ, net calorific value
Use of net fresh water
M
Components for re-use kg
Materials for recycling kg
Materials for energy recovery kg
Exported energy MJ per energy carrier
5 Descriptive features
5.1 Data for potential use with room ventilation systems: type of appliance (in relation
to its tightness to the room)
The designation of the appliance in relation to the potential use with ventilation systems shall be given
in accordance with EN 16510-1:2022, 4.1.
5.2 Data for the building's statics: appliance's mass
The appliance’s mass in relation to the building’s statics shall be given in accordance with
EN 16510-1:2022, 7.2, paragraph 8.
5.3 Materials and construction elements
5.3.1 General
The shape and dimensions of the components and equipment and the method of design and manufacture
and, if assembled on site, the method of assembly and installation, shall ensure that, when operated as
specified in accordance with the test procedures of this document and exposed to the associated
mechanical, chemical and thermal stresses, the appliance shall operate reliably and safely such that
during normal operation no combustion gas posing a hazard can escape into the room in which the
appliance is installed nor can embers fall out.
Non-combustible materials (materials in accordance with EN 16510-1:2022, 4.4.1.1) shall be used,
except that it shall be permissible to use combustible materials for the following applications:
— components or accessories fitted outside the appliance;
— internal components of controls and safety equipment;
— operating handles;
— electrical equipment.
5.3.2 General stresses
The proper operation of the appliance in relation to the general stresses to materials and construction
elements shall be tested in accordance with EN 16510-1:2022, 4.4.1 and 4.4.2.
prEN 1650-2-9:2026 (E)
5.3.3 Pellet basket compartment
Where the pellet basket is removable, the pellet basket compartment shall be designed or marked to
ensure correct assembly and positioning.
If the ashpan or the ashpit is part of the pellet basket compartment, the de-ashing operation should be
possible without undue effort. If it is necessary to remove the ashpit door to de-ash the fire, the appliance
should be designed such that there is no undue spillage of ash or fuel from the appliance during the de-
ashing operation.
The preferred design should allow the pellet basket removal for extraordinary maintenance but at the
same time should allow the de-ashing without necessarily removing the pellet basket.
5.4 Risk of burning fuel falling out
This subclause is not applicable.
5.5 Temperature rise in the fuel storage, if any
The rise of the temperature above ambient temperature in the fuel storage shall be tested in accordance
with EN 16510-1:2022, 5.4. This rise of the temperature shall not exceed 65 K.
5.6 Temperature rise of the operating components
The rise of the temperature above ambient temperature of the operation components shall be tested in
accordance with EN 16510-1:2022, 5.5. This rise of the temperature shall not exceed the material specific
limits given in EN 16510-1:2022, 5.5.
5.7 Spillage of flue gases into the room
5.7.1 Possible spillage of CO, if relevant for the fuel type
The prevention of possible spillage of CO shall be tested in accordance with EN 16510-1:2022, 5.1
and A.4.10.5 depending on the intended fuel type.
5.8 Cleanability
5.8.1 Heating surfaces
The safety of the heating surfaces especially in relation to cleanability shall be tested in accordance with
EN 16510-1:2022, 4.4.3.
5.8.2 Flueways
The safety of the flueways especially in relation to cleanability shall be tested in accordance with
EN 16510-1:2022, 4.4.5.
5.8.3 Ashpan
If an ashpan is fitted its safety especially in relation to cleanability shall be tested in accordance with
EN 16510-1:2022, 4.4.7.
5.8.4 bottomgrate
If a bottomgrate is fitted its safety especially in relation to cleanability shall be tested in accordance with
EN 16510-1:2022, 4.4.8.
5.8.5 Pellet basket bottomgrid
Where the pellet basket bottomgrid is removable it shall be so designed or marked as to ensure correct
fitting.
If a de-ashing mechanism is fitted it shall be capable of effectively de-ashing the firebed. The pellet basket
bottomgrid shall not become dislodged during the de-ashing process.
The preferred design with the charging door(s) and ashpit door(s) closed shall allow de-ashing to be
carried out. The de-ashing shall be possible without undue effort.
If it is necessary to remove the ashpit door to de-ash the fire, the appliance shall be designed to minimize
ash or fuel spillage during the de-ashing operation.
5.8.6 Damper
If a damper is fitted its safety especially in relation to cleanability shall be tested in accordance with
EN 16510-1:2022, 4.4.10.
5.8.7 Fan-cut-out-device
This subclause is not applicable.
6 Assessment and verification of constancy of performance - AVCP
6.1 General
The technical details necessary for the implementation of the system of assessment and verification of
constancy of performance comprise provisions with regards to:
— the assessment of the performance of the residential solid fuel burning appliance, which may be
carried out on the basis of testing (including sampling), calculation, tabulated values or descriptive
documentation of the product and
— the applicable factory production control
6.2 Assessment of performance
6.2.1 General
When the intention shall declare any performance related to characteristics included in Annex A of this
document this shall be carried out on the basis of testing (including sampling), calculation, tabulated
values or descriptive documentation of the product, in accordance with clause 'characteristics'.
Assessment previously performed in accordance with the provisions of this document may be considered
provided that this assessment was made to the same or a more rigorous assessment method, under the
same AVCP system on the same product or products of similar design, construction and functionality,
such that the results are applicable to the product in question.
For the purposes of assessment, the products may
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...