Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent

This European Standard specifies requirements, test methods, evaluation of conformity and marking for prefabricated secondary treatment units used for the treatment of effluent from septic tanks according to EN 12566-1 or EN 12566-4 in small wastewater treatment systems for up to 50 PT.
NOTE   Equivalent septic effluent may come from existing septic tanks.
It applies to the prefabricated secondary treatment unit, where all its components are packaged or site-assembled and placed on the market as a kit by one manufacturer.
The prefabricated secondary treatment unit consists of one or more tanks made of concrete, steel, unplasticised polyvinylchloride (PVC-U), polyethylene (PE), glass reinforced polyester (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) or container made of flexible sheets (PEHD, PP, PVC, EPDM). Other components specified by the manufacturer, such as pipes, pumps and filter material will be considered as part of the unit.
This standard establishes the performance of the prefabricated secondary treatment units needed to verify their suitability for the end use conditions for which the test methods are specified.
This standard applies for the packaged and/or site assembled secondary treatment units for use on the top of the ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit.
This standard does not cover:
-   non watertight secondary treatment units with direct infiltration into the ground;
-   retrofit kits (see definition in 3.7).

Kleinkläranlagen für bis zu 50 EW - Teil 6: Vorgefertigte Anlagen für die weitergehende Behandlung des aus Faulgruben ablaufenden Abwassers

Diese Europäische Norm legt Anforderungen, Prüfverfahren, die Konformitätsbewertung und die Kennzeich-nung für vorgefertigte Anlagen der zweiten Reinigungsstufe fest, die für die Behandlung des aus Faulgruben ablaufenden Abwassers nach EN 12566-1 oder EN 12566-4 in Kleinkläranlagen für bis zu 50 EW verwendet werden.
ANMERKUNG   Gleichwertiges aus Faulgruben ablaufendes Abwasser kann aus bestehenden Faulgruben stammen.
Sie gilt für vorgefertigte Anlagen der zweiten Reinigungsstufe, bei denen sämtliche Komponenten vorgefertigt sind oder vor Ort montiert werden, und durch den Hersteller als Bausatz auf den Markt gebracht werden.
Die vorgefertigte Anlage der zweiten Reinigungsstufe besteht aus einem Behälter oder mehreren Behältern aus Beton, Stahl, weichmacherfreiem Polyvinylchlorid (PVC-U), Polyethylen (PE), glasfaserverstärktem Kunststoff auf der Basis von ungesättigtem Polyesterharz (GFK-UP), Polypropylen (PP), Polydicyclopentadien (PDCPD) oder aus einem Behälter aus flexiblen Bahnen (PEHD, PP, PVC, EPDM). Weitere, durch den Hersteller spezifizierte Baugruppen, wie Rohrleitungen, Pumpen und Filtermaterial, werden als Teil der Anlage angesehen.
Diese Norm legt die Leistung von vorgefertigten Anlagen der zweiten Reinigungsstufe fest, die zur Verifi-zierung ihrer Eignung für die Endanwendungsbedingungen erforderlich ist, und für die die Prüfverfahren fest-gelegt sind.
Diese Norm gilt für Anlagen der zweiten Reinigungsstufe, die vorgefertigt sind oder vor Ort montiert werden, und die auf der Bodenoberfläche verwendet werden (außerhalb eines Gebäudes) oder so im Boden eingebaut sind, dass keine Fahrzeuglasten auf die Anlage wirken.
Diese Norm behandelt keine:
-   nicht wasserdichten Anlagen der zweiten Reinigungsstufe mit direkter Infiltration in den Boden;
-   Nachrüstsätze (siehe Begriff 3.7).

Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 6: Unités préfabriquées de traitement des effluents de fosses septiques

La présente Norme européenne spécifie les exigences, les méthodes d'essai, l'évaluation de la conformité et le marquage d'unités préfabriquées de traitement secondaire utilisées pour le traitement des effluents s'écoulant de fosses septiques conformément à l'EN 12566-1 ou à l'EN 12566-4 dans les petites installations de traitement des eaux usées jusqu’à 50 PTE.
Elle s'applique à l'unité préfabriquée de traitement secondaire, lorsque tous ses composants sont assemblés en usine ou sur site et mis sur le marché sous forme de kit par un fabricant.
Ces unités préfabriquées de traitement secondaire sont étanches sans aucune infiltration directe dans le sol.
L'unité préfabriquée de traitement secondaire est constituée d'un ou plusieurs réservoirs en béton, en acier, en polychlorure de vinyle non plastifié (PVC-U), en polyéthylène (PE), polyester renforcé de verre (GRP-UP) ou en polypropylène (PP). D'autres composants spécifiés par le fabricant, tels que des tuyaux, des pompes et du matériel de filtration peuvent être utilisés dans l'unité.
La présente norme établit les performances des unités préfabriquées de traitement secondaire nécessaires pour vérifier leur aptitude aux conditions d'usage final pour lesquelles les méthodes d'essai sont spécifiées.
La présente norme est applicable aux unités de traitement secondaires destinées à un usage non enterré (à l’extérieur du bâtiment), ou enterrées à un emplacement où l'unité n’est pas soumise à des charges dues aux véhicules.
Les kits de remise à niveau (voir la définition 3.7) ne relèvent pas de la présente norme.

Male čistilne naprave do 50 PE - 6. del: Predizdelane enote za obdelavo grezničnih odplak

Ta evropski standard določa zahteve, preskusne metode, vrednotenje skladnosti in označevanje predizdelanih sekundarnih enot za obdelavo, ki se uporabljajo pri obdelavi grezničnih odplak v skladu s standardom EN 12566-1 ali EN 12566-4 v malih čistilnih napravah do 50 PE. Uporablja se za predizdelane sekundarne enote za uporabo, ki imajo vse dele pakirane ali izdelane za sestavljanje na mestu in so na trgu na voljo kot kompleti enega proizvajalca. Predizdelana sekundarna enota za obdelavo je sestavljena iz enega ali več rezervoarjev, ki so izdelani iz betona, jekla, neplastificiranega polivinil klorida (PVC-U), polietilena (PE), s steklom ojačanega poliestra (GRP-UP), polipropilena (PP), polidiciklopentadiena (PDCPD), ali iz posode, ki je izdelana iz elastičnih trakov (PEHD, PP, PVC, EPDM). Drugi deli, ki jih navede proizvajalec (npr. cevi, črpalke in material filtra), so obravnavani kot del enote. Ta standard določa zmogljivost predizdelanih sekundarnih enot za obdelavo, ki je potrebna za dokazovanje njihove primernosti za končno uporabo v pogojih, za katere so določene preskusne metode. Ta standard se uporablja za sekundarne enote za uporabo, ki so pakirane in/ali izdelane za sestavljanje na mestu ter se uporabljajo nad zemljo (pred stavbo) ali so zakopane pod zemljo, kjer ni vozil, ki obremenjujejo enoto.

General Information

Status
Withdrawn
Publication Date
12-Feb-2013
Withdrawal Date
13-Apr-2025
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
31-Aug-2016
Completion Date
14-Apr-2025

Relations

Effective Date
07-Sep-2016
Standard – translation

EN 12566-6:2013

Slovenian language
39 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 12566-6:2013 is a standard published by the European Committee for Standardization (CEN). Its full title is "Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent". This standard covers: This European Standard specifies requirements, test methods, evaluation of conformity and marking for prefabricated secondary treatment units used for the treatment of effluent from septic tanks according to EN 12566-1 or EN 12566-4 in small wastewater treatment systems for up to 50 PT. NOTE Equivalent septic effluent may come from existing septic tanks. It applies to the prefabricated secondary treatment unit, where all its components are packaged or site-assembled and placed on the market as a kit by one manufacturer. The prefabricated secondary treatment unit consists of one or more tanks made of concrete, steel, unplasticised polyvinylchloride (PVC-U), polyethylene (PE), glass reinforced polyester (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) or container made of flexible sheets (PEHD, PP, PVC, EPDM). Other components specified by the manufacturer, such as pipes, pumps and filter material will be considered as part of the unit. This standard establishes the performance of the prefabricated secondary treatment units needed to verify their suitability for the end use conditions for which the test methods are specified. This standard applies for the packaged and/or site assembled secondary treatment units for use on the top of the ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not cover: - non watertight secondary treatment units with direct infiltration into the ground; - retrofit kits (see definition in 3.7).

This European Standard specifies requirements, test methods, evaluation of conformity and marking for prefabricated secondary treatment units used for the treatment of effluent from septic tanks according to EN 12566-1 or EN 12566-4 in small wastewater treatment systems for up to 50 PT. NOTE Equivalent septic effluent may come from existing septic tanks. It applies to the prefabricated secondary treatment unit, where all its components are packaged or site-assembled and placed on the market as a kit by one manufacturer. The prefabricated secondary treatment unit consists of one or more tanks made of concrete, steel, unplasticised polyvinylchloride (PVC-U), polyethylene (PE), glass reinforced polyester (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) or container made of flexible sheets (PEHD, PP, PVC, EPDM). Other components specified by the manufacturer, such as pipes, pumps and filter material will be considered as part of the unit. This standard establishes the performance of the prefabricated secondary treatment units needed to verify their suitability for the end use conditions for which the test methods are specified. This standard applies for the packaged and/or site assembled secondary treatment units for use on the top of the ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not cover: - non watertight secondary treatment units with direct infiltration into the ground; - retrofit kits (see definition in 3.7).

EN 12566-6:2013 is classified under the following ICS (International Classification for Standards) categories: 13.060.30 - Sewage water. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 12566-6:2013 has the following relationships with other standards: It is inter standard links to EN 12566-6:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 12566-6:2013 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/118, M/131. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 12566-6:2013 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.RGSODNKleinkläranlagen für bis zu 50 EW - Teil 6: Vorgefertigte Anlagen für die weitergehende Behandlung des aus Faulgruben ablaufenden AbwassersPetites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 6: Unités préfabriquées de traitement des effluents de fosses septiquesSmall wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent13.060.30Odpadna vodaSewage waterICS:Ta slovenski standard je istoveten z:EN 12566-6:2013SIST EN 12566-6:2013en,fr,de01-junij-2013SIST EN 12566-6:2013SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12566-6
February 2013 ICS 13.060.30 English Version
Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units for septic tank effluent
Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 6: Unités préfabriquées de traitement des effluents de fosses septiques
Kleinkläranlagen für bis zu 50 EW - Teil 6: Vorgefertigte Anlagen für die weitergehende Behandlung des aus Faulgruben ablaufenden Abwassers This European Standard was approved by CEN on 7 December 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12566-6:2013: ESIST EN 12566-6:2013

Secondary treatment efficiency test procedure . 23 A.1 Selection of the unit and its preliminary evaluation . 23 A.1.1 General . 23 A.1.2 Installation and commissioning. 23 A.1.3 Operation and maintenance procedures during testing . 23 A.1.4 Data to be monitored . 23 A.2 Test procedure . 24 A.2.1 Time for establishment . 24 A.2.2 Influent characteristics . 24 A.2.3 Daily flow pattern for testing. 24 A.2.4 Test method . 24 A.2.5 Influent and effluent sampling . 26 A.3 Sample analysis . 26 A.4 Test report . 26 Annex B (normative)
Presentation of the micro-organisms test results . 28 Annex C (informative)
Analysis method . 29 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 30 ZA.1 Scope and relevant characteristics . 30 ZA.2 Procedure of attestation of conformity of prefabricated secondary treatment units. 32 ZA.2.1 Systems of attestation of conformity . 32 ZA.2.2 EC certificate of conformity and EC declaration of conformity. 34 ZA.3 CE marking and labelling . 35 Bibliography . 38
Key A raw domestic wastewater 1 prefabricated septic tank B septic tank effluent 2 soil infiltration system C treated infiltrated effluent 3 packaged and/or site assembled domestic wastewater treatment plant D treated wastewater 4 septic tank assembled in situ from prefabricated kit E tertiary treated wastewater 5 pre-treated effluent filtration system
6 prefabricated treatment unit used for septic tank effluent
7 prefabricated tertiary treatment unit
Figure 1 — Scheme related to the arrangement of the parts of EN 12566 or CEN/TR 12566 NOTE National regulations may specify different arrangements between the products described in the series of EN 12566 and CEN/TR 12566. SIST EN 12566-6:2013

NOTE 2 The requirements to provide facility for the access of a person into the prefabricated secondary treatment unit may depend on applicable regulations, valid in the member state for the intended end use conditions. For example, the minimum dimension of the opening for the access of a person in EN 476 is 600 mm. Extension shafts, where applicable, and access covers of the prefabricated secondary treatment unit shall be designed to be fit for purpose. The access dimensions shall be declared. Assessment of access dimension shall be carried out by a measurement with accuracy of 0,5 % of the dimension. 6.2 Load bearing capacity 6.2.1 General For units not including a tank, load bearing capacity assessment is not required. Test methods and values for mechanical characteristics of the materials of the tank, used for calculation of the load bearing capacity of the tank, shall be in accordance with EN 12566-3:2005+A1:2009, Annex C. The prefabricated secondary treatment units shall be able to withstand the loads resulting from handling, installation and use including desludging and maintenance, for its design life. For buried installation, the load bearing capacity of the prefabricated secondary treatment unit (i.e. of the tank of this unit) shall be established:  either by calculation with the knowledge of basic data for material and loads (see 6.2.2);
or  by test directly on the tank component of the unit (see 6.2.3). Where the prefabricated secondary treatment unit includes a watertight extension shaft, and/or the unit is installed in a water table, the relevant loads at the maximum installed depth of the unit shall be taken into account and appropriate tests or calculations made to prove the load bearing capacity of the unit. SIST EN 12566-6:2013

2) Properties of the materials and components: All parameters given in chapter durability (6.6). The manufacturer shall provide in the installation instructions the height of backfill and the possibility to install the unit in a water table or not (WET or DRY), respectively. NOTE If required, the manufacturer may provide the calculation results according to the calculation method valid in the place of use. b) Method 2: Directly declaring the performance using the applicable Eurocode: 1) Eurocode 2 for concrete (where applicable), 2) Eurocode 3 for steel (where applicable). The manufacturer shall provide the calculation results according to the relevant Eurocode in terms of height of backfill and possibility to install the unit in a water table or not (WET or DRY), respectively. 6.2.2.2 Backfill loads Calculation of backfill loads shall be carried out according to EN 12566-3:2005+A1:2009, 6.2.1.2. 6.2.2.3 Hydrostatic loads A vertical and a horizontal component of the hydrostatic loads shall be calculated according to EN 12566-3:2005+A1:2009, 6.2.1.3. 6.2.2.4 Pedestrian loads For pedestrian loads, a value of 2,5 kN/m2 shall be considered in calculation only when the height of the backfill (h) is less than or equal to 1 m. Over 1 m, the pedestrian loads do not need to be taken into account for calculation, as it is assumed to be negligible against other loads. 6.2.3 Load bearing capacity determined by testing The load bearing capacity of the prefabricated secondary treatment unit shall be established by the crushing resistance or maximum load deformation according to EN 12566-3:2005+A1:2009, Annex C. SIST EN 12566-6:2013

Key . friction angle: . ≤ 63° Figure 2 — Pit test for open unit 6.3 Secondary treatment efficiency 6.3.1 General For the purpose of determination of the secondary treatment efficiency, the prefabricated secondary treatment unit shall be tested according to Annex A. 6.3.2 Secondary treatment efficiency ratio The prefabricated secondary treatment unit shall demonstrate compliance with the declared performance. This performance shall be expressed and declared in terms of secondary treatment efficiency ratios on COD, BOD and SS concentration together with:  the tested COD, BOD and SS influent daily load;  or characteristics (hydraulic efficiency, nominal capacity, etc.) of the septic tank used during the test expressed according to EN 12566-1 or EN 12566-4. The tested daily load shall be the mean value of the 20 daily loads measured during the nominal sequences of the test as described in Annex A. The secondary treatment efficiency ratios on COD, BOD and SS shall be given in the documentation. When requested, nitrogen parameters and total phosphorus shall be analysed during the test. In this case related secondary treatment efficiency ratios shall also be declared. SIST EN 12566-6:2013

RST is the secondary treatment efficiency ratio for a given parameter (e.g. COD, BOD, SS); Pi is the value of the given parameter at the inlet of the prefabricated secondary treatment unit; Po is the value of the same given parameter at the outlet of the prefabricated secondary treatment unit. Any secondary treatment efficiency ratio (RST) declared for a given daily load shall not be greater than the mean value of the secondary treatment efficiency ratio obtained during the test made according to Annex A. The secondary treatment efficiency ratios obtained do not automatically mean that the regulatory requirements on effluent qualities in a given place are met. A calculation should be made to indicate the final effluent qualities which will be compared to the requirements valid in the place of intended use of the unit. These ratios are laboratory determined but may not always be obtained when a unit is installed on a user site. 6.3.3 Micro-organism reduction When the micro-organism reduction of the prefabricated secondary treatment unit is to be declared, the results of the tests (i.e. influent and effluent values) shall be expressed and declared in unit (i.e. cfu/100 ml or MPN/100 ml). The reduction shall be expressed in logarithmic unit. All results shall be given in a specific document as described in Annex B. The recorded microorganism reduction does not automatically mean that the regulatory requirements on effluent qualities in a given Member state are met. It should be compared to the requirements valid in the place of intended use. The micro-organism reduction may not always be obtained when the unit is operating in practice. 6.4 Watertightness When tested according to EN 12566-3:2005+A1:2009, Annex A, the prefabricated secondary treatment units for septic tank effluent shall meet the watertightness requirements of EN 12566-3:2005+A1:2009, 6.4. Where the top of the unit is open, the watertightness test shall be performed by filling it up to the top. For a unit made with PDCPD, watertightness test shall be the one given in EN 12566-3:2005+A1:2009, A.2. 6.5 Power consumption Where applicable, the power consumption of the unit shall be declared. It shall be measured during the test described in Annex A and expressed as the consumption for the normal operating conditions (nominal sequences of the test) in kWh/d. The declared power consumption value shall be higher or equal to the measured value during the test in A.2.4.5. Assessment of power consumption shall be done by measurement with accuracy of ± 5 % of the result. SIST EN 12566-6:2013

In most cases Class E is considered to be sufficient as a minimum regulatory requirement for the reaction to fire performance of units used in buried (i.e. underground) applications. Conversely, where use of such a unit is not subject to national regulatory requirements on reaction to fire, either class, determined according to a) or b) or Class F (see Note 2) may be declared. NOTE 2
Class F according to EN 13501-1 is equivalent to "No Performance Determined" (NPD).
6.7.2 Units classified as Class A1 without the need for testing The reaction to fire performance of a unit shall be declared as Class A11) without the need for testing, provided that: a) each of the constituent materials that the tank of the unit is made of, contains not more than 1 % of homogeneously distributed organic material, by mass or volume (whichever is the most onerous), and EXAMPLE
In general, precast reinforced concrete used for prefabricated secondary treatment unit may contain organic materials (e.g. admixtures, additives) if any, but their level is far below 1 %. Similarly, steel, used for the same purpose, is not used in a finely divided form. Thus, on account of their low level of combustibility and subject to the conditions set out (see Footnote 1) both materials may be considered, without testing, as class A1 materials for their reaction to fire performance. b) any external coating, if applied over the surface area of the tank, is made on inorganic material(s) with thickness ≥ 1,0 mm or mass per unit area ≥ 1,0 kg/m2, which is/are also classified as Class A1. 6.7.3 Units classified according to the test results For the purpose of the reaction to fire performance of the unit, each of its constituent materials, including those in the surface coating of the unit, if any, shall be classified according to EN 13501-1 and only the lowest class of such materials shall be declared. The class of an individual constituent material shall be obtained as the result of the test method(s), relevant to this class, and as specified in the standards referred to in EN 13501-1. NOTE
A constituent material of the unit is considered as the material which may have a significant effect on the reaction to fire performance of such unit. According to the definitions given in EN 13501-1, this may be in case of:  homogeneous unit: its material, or  non-homogeneous unit: its substantial component, i.e. a material that constitutes a significant part of such unit. A layer with a mass per unit area ≥ 1,0 kg/m2 or a thickness ≥ 1,0 mm is considered to be a substantial component.
1) See Decision of the Commission 96/603/EC of 1996-10-04 (see OJEU L 267 of 1996-10-19), as twice amended by 2000/605/EC of 2000-09-26 (see OJEU L 258 of 2000-10-12) and by 2003/424/EC of 2003-06-06 (see OJEU L 144 of 2003-06-12). SIST EN 12566-6:2013

In general, this may be considered relevant for the unit where the tank is made from one or more of the following constituent materials: unplasticised polyvinylchloride (PVC-U), polyethylene (PE), glass reinforced polyester (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD); or the container is made from flexible sheets (PEHD, PP, PVC, OR EPDM), with or without surface coating. Test specimens used for the test methods, applicable for this classification, shall be prepared according to EN 13501-1 and to the relevant standards referred therein. 6.8 Dangerous substances National regulations on dangerous substances may require verification and declaration on release, and sometimes content, when construction products covered by this standard are placed on those markets. In the absence of European harmonised test methods, verification and declaration on release/content should be done taking into account national provisions in the place of use. NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/ . 7 Evaluation of conformity 7.1 General The conformity of a prefabricated secondary treatment unit with the requirements of this standard and with the declared performances for the stated characteristics (e.g. values, classes) shall be demonstrated by:  initial type testing (ITT) and type testing (TT), if any (see 7.2);  factory production control by the manufacturer, including unit assessment (see 7.3). The manufacturer shall always retain the overall control and shall have the necessary means to take responsibility for the unit. 7.2 Initial type testing – Type testing 7.2.1 General Initial type testing (ITT) and type testing (TT), if any, shall be performed to demonstrate compliance of the prefabricated secondary treatment unit with this European Standard. All essential characteristics, as given in bold letters in Table 2, for which the performances are to be declared for the relevant intended use of the prefabricated secondary treatment unit, shall be subject to ITT. NOTE 1 In general, ITT may not be needed for characteristics, which performances in this standard are referred to the following cases/uses: previously existing data, CWT or CWFT or conventionally accepted performance (CAP). However, in case where certain requirements are given for application of such case/use (e.g. CWFT), ITT may be limited to meet such requirements using the appropriate test/assessment methods, defined herein. In addition to ITT, type tests (TT) of the prefabricated secondary treatment unit shall be performed to all other characteristics included in this standard, if any (see Table 2), when compliance with this standard is claimed. SIST EN 12566-6:2013

6.2.1 and 6.2.2 According to 6.2.2 One unit of the family b Declared values: max depth of backfill (in m) and Wet or Dry 5.2 Load bearing capacity, tested 6.2.1 and 6.2.3 According to 6.2.3 d and EN 12566-3:2005 +A1:2009, Annex C One unit of the family b Declared values: max depth of backfill (in m) and Wet or Dry 6 Power consumption 6.5 According to 6.5 One unit of the family Declared value: power consumption (in kWh/d) during normal operating conditions (nominal sequences). 7 Durability c
for units made of: Concrete, steel, PVC-U, PE, GRP 6.6.2 EN 12566-3:2005+A1: 2009, 6.5.2 to 6.5.7 – Declared as “Pass” or “Fail” according to material used and test method applied
PDCPD 6.6.3 Acc. to standards referred in 6.6.3 Flexible sheets 6.6.4 Acc. to standards referred in 6.6.4 8 Reaction to fire 6.7.2 - Each material(s) Declared class A1 (CWT) 6.7.3 Acc. to standards referred in 6.7.3 Declared the lowest class acc. to EN 13501-1 of the relevant material 9 Dangerous substances 6.8 As relevant according to substance and intended place of use Each material As relevant, according to substance and intended place of use a The worst case unit for secondary treatment efficiency according to the scaling rules shall be selected for testing. The smallest is generally considered as the worst case, but this shall be verified according to the scaling rules. b The worst case unit for load bearing capacity according to the scaling rules shall be selected for testing. The biggest is generally
considered as the worst case, but this shall be verified according to the scaling rules. c Test methods of the materials, which the unit is made of, including their components (i.e. corrosion protective coating), if they
...


SLOVENSKI SIST EN 12566-6
STANDARD
junij 2013
Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za obdelavo

grezničnih odplak
Small wastewater treatment systems for up to 50 PT – Part 6: Prefabricated

treatment units for septic tank effluent

Petites installations de traitement des eaux usées jusqu'à 50 PTE –

Partie 6: Unités préfabriquées de traitement des effluents de fosses septiques

Kleinkläranlagen für bis zu 50 EW – Teil 6: Vorgefertigte Anlagen für die

weitergehende Behandlung des aus Faulgruben ablaufenden Abwassers

Referenčna oznaka
ICS 13.060.30 SIST EN 12566-6:2013 (sl)

Nadaljevanje na straneh II in III ter od 1 do 37

© 2016-05. Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST EN 12566-6 : 2013
NACIONALNI UVOD
Standard SIST EN 12566-6 (sl), Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za
obdelavo grezničnih odplak, 2013, ima status slovenskega standarda in je istoveten evropskemu
standardu EN 12566-6 (en, de, fr), Small wastewater treatment systems for up to 50 PT – Part 6:
Prefabricated treatment units for septic tank effluent, 2013.

NACIONALNI PREDGOVOR
Evropski standard EN 12566-6:2013 je pripravil tehnični odbor Evropskega komiteja za standardizacijo
CEN/TC 165 Odvajanje in čiščenje odpadne vode. Slovenski standard SIST EN 12566-6:2013 je prevod
evropskega standarda EN 12566-6:2013. V primeru spora glede besedila slovenskega prevoda v tem
standardu je odločilen izvirni evropski standard v enem izmed treh uradnih jezikov CEN. Slovensko
izdajo standarda je potrdil Strokovni svet SIST za splošno področje.

Odločitev za izdajo tega standarda je oktobra 2012 sprejel Strokovni svet SIST za splošno področje.

ZVEZA S STANDARDI
S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST EN 1085:2007 Čiščenje odpadne vode – Slovar
SIST EN 12566-1 Male čistilne naprave do 50 PE – 1. del: Predizdelane greznice
SIST EN 12566-3:2005+A1:2013 Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake
SIST EN 12566-4 Male čistilne naprave do 50 PE – 4. del: Montažne greznice, sestavljene na
mestu vgradnje
SIST EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni in
elastomerni trakovi za tesnjenje streh
SIST EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj
SIST EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine
SIST EN ISO 527-1 Polimerni materiali – Ugotavljanje nateznih lastnosti – 1. del: Splošna načela
(ISO 527-1)
SIST EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)
SIST EN ISO 7899-1 Kakovost vode – Ugotavljanje prisotnosti in števila intestinalnih enterokokov v
površinskih in odpadnih vodah – 1. del: Metoda z miniaturizacijo (najbolj
verjetno število) z nasajanjem v tekočem gojišču (ISO 7899-1)
SIST EN ISO 7899-2 Kakovost vode – Ugotavljanje prisotnosti in števila intestinalnih enterokokov –
2. del: Metoda membranske filtracije (ISO 7899-2)
SIST EN ISO 9308-1 Kakovost vode – Ugotavljanje števila Escherichia coli in koliformnih bakterij –
1. del: Metoda membranske filtracije za vode z majhnim številom
spremljajočih bakterij (ISO 9308-1)
SIST EN ISO 9308-3 Kakovost vode – Ugotavljanje prisotnosti in števila Escherichia coli in
koliformnih bakterij v površinski in odpadnih vodah – 3. del: Metoda z
miniaturizacijo (najbolj verjetno število) z nasajanjem v tekočem gojišču (ISO
9308-3)
II
SIST EN 12566-6 : 2013
OSNOVA ZA IZDAJO STANDARDA
– privzem standarda EN 12566-6:2013

OPOMBE
– Povsod, kjer se v besedilu standarda uporablja izraz “evropski standard”, v SIST EN 12566-6:2013
to pomeni “slovenski standard”.
– Uvod in nacionalni predgovor nista sestavni del standarda.
– Ta nacionalni dokument je istoveten EN 12566-6:2013 in je objavljen z dovoljenjem
CEN
Upravni center
Avenue Marnix 17
B-1000 Bruselj
This national document is identical with EN 12566-6:2013 and is published with the permission of
CEN
Management Centre
Avenue Marnix 17
B-1000 Brussels
III
EVROPSKI STANDARD EN ISO 12566-6
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM februar 2013
ICS 13.060.30
Slovenska izdaja
Male čistilne naprave do 50 PE –
6. del: Predizdelane enote za obdelavo grezničnih odplak

Small wastewater treatment Petites installations de traitement Kleinkläranlagen für bis zu 50
systems for up to 50 PT – des eaux usées jusqu'à 50 PTE – EW – Teil 6: Vorgefertigte
Part 6: Prefabricated treatment Partie 6: Unités préfabriquées de Anlagen für die weitergehende
units for septic tank effluent traitement des effluents de fosses Behandlung des aus Faulgruben
septiques ablaufenden Abwassers

Ta evropski standard je CEN sprejel dne 7. decembra 2012.

Člani CEN morajo izpolnjevati določila notranjih predpisov CEN/CENELEC, s katerimi je predpisano,
da mora biti ta evropski standard brez kakršnihkoli sprememb sprejet kot nacionalni standard. Seznami
najnovejših izdaj teh nacionalnih standardov in njihovi bibliografski podatki so na voljo pri Upravnem
centru ali članih CEN.
Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski in nemški). Izdaje v drugih
jezikih, ki jih člani CEN na lastno odgovornost prevedejo in izdajo ter prijavijo pri upravnem centru CEN,
veljajo kot uradne izdaje.
Člani CEN so nacionalni organi za standarde Avstrije, Belgije, Bolgarije, Cipra, Češke republike, Danske,
Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.
CEN
Evropski komite za standardizacijo
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung

Upravni center: Avenue Marnix, 17, B-1050 Brussels

© 2013 CEN. Lastnice avtorskih pravic so vse države članice CEN Ref. oznaka: EN ISO 12566-6:2013 E

SIST EN 12566-6 : 2013
VSEBINA Stran
Predgovor . 4
1 Področje uporabe . 6
2 Zveze s standardi . 6
3 Izrazi in definicije . 7
4 Simboli in kratice . 7
5 Nazivna oznaka . 8
6 Zahteve . 8
6.1 Projektiranje . 8
6.1.1 Splošno . 8
6.1.2 Skupne dimenzije . 8
6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki . 8
6.1.4 Dostop . 9
6.2 Obremenitvena zmogljivost . 9
6.2.1 Splošno . 9
6.2.2 Obremenitvena zmogljivost, določena z izračunom . 10
6.2.3 Obremenitvena zmogljivost, določena s preskušanjem . 10
6.3 Učinkovitost sekundarnega čiščenja . 11
6.3.1 Splošno . 11
6.3.2 Stopnja učinkovitosti sekundarnega čiščenja . 11
6.3.3 Zmanjšanje količine prisotnih mikroorganizmov . 12
6.4 Vodotesnost . 12
6.5 Poraba energije . 12
6.6 Trajnost . 12
6.6.1 Splošno . 12
6.6.2 Beton, jeklo, PVC-U, PE, GRP . 13
6.6.3 PDCPD . 13
6.6.4 Hidroizolacijski trakovi . 13
6.7 Odziv na ogenj . 13
6.7.1 Splošno . 13
6.7.2 Enote, klasificirane kot razred A1, brez potrebe po preskušanju . 14
6.7.3 Enote, klasificirane v skladu z rezultati preskušanja . 14
6.8 Nevarne snovi . 14
7 Vrednotenje skladnosti . 14
7.1 Splošno . 14
7.2 Začetno tipsko preskušanje – tipsko preskušanje . 15
7.2.1 Splošno . 15
7.2.2 Vzorčenje, preskušanje in merila skladnosti . 17
7.2.3 Poročila o preskusih . 17
7.3 Kontrola proizvodnje v obratu (FPC) . 17
SIST EN 12566-6 : 2013
7.3.1 Splošno . 17
7.3.2 Zahteve . 17
7.3.3 Postopek za spremembe . 19
7.3.4 Začetni pregled obrata in kontrole proizvodnje v obratu . 20
7.3.5 Stalni nadzor nad kontrolo proizvodnje v obratu . 20
8 Označevanje . 20
8.1 Označevanje enote . 20
8.2 Enoti priložene tehnične informacije, . 20
9 Navodila za vgradnjo . 21
10 Navodila za obratovanje in vzdrževanje . 21
Dodatek A (normativni): Postopek za preskušanje učinkovitosti sekundarnega čiščenja . 22
Dodatek B (normativni): Predstavitev rezultatov preskusa prisotnosti mikroorganizmov . 27
Dodatek C (informativni): Analizna metoda . 28
Dodatek ZA (informativni): Točke tega evropskega standarda, v katerih so obravnavane
določbe Direktive EU o gradbenih proizvodih . 29
Literatura. 37

SIST EN 12566-6 : 2013
Predgovor
Ta dokument (EN 12566-6:2013) je pripravil tehnični odbor CEN/TC 165 Odvajanje in čiščenje odpadne
vode, katerega sekretariat vodi DIN.

Ta evropski standard mora dobiti status nacionalnega standarda bodisi z objavo istovetnega besedila
ali z razglasitvijo najpozneje do avgusta 2013, nasprotujoče nacionalne standarde pa je treba
umakniti najpozneje avgusta 2013.

Opozoriti je treba na možnost, da so lahko nekateri elementi tega dokumenta predmet patentnih pravic.
CEN [in/ali CENELEC] ne prevzemata odgovornosti za identifikacijo nekaterih ali vseh takih patentnih
pravic.
Ta dokument je bil pripravljen na podlagi mandata, ki sta ga Evropska komisija in Evropsko
združenje za prosto trgovino podelila CEN, in podpira bistvene zahteve direktive (direktiv) EU.

Za povezavo z direktivo(-ami) Evropske unije glej dodatek ZA, ki je sestavni del tega dokumenta.

Skupina standardov EN 12566 "Male čistilne naprave do 50 PE" vključuje naslednje dele:
– 1. del: Predizdelane greznice
– 3. del: Predizdelane in/ali na mestu postavitve sestavljene čistilne naprave za gospodinjske odplake
– 4. del: Montažne greznice, sestavljene na mestu vgradnje
– 6. del: Predizdelane enote za obdelavo grezničnih odplak (ta standard)
– 7. del: Predizdelane terciarne čistilne enote (v pripravi)

Za sisteme za filtriranje in infiltracijo je CEN/TC 165 objavil naslednji tehnični poročili CEN, ki se
upoštevata kot pravila ravnanja in ne določata zahtev za čiščenje:
– CEN/TR 12566-2, Male čistilne naprave do 50 PE – 2. del: Sistemi za infiltracijo v zemljo
– CEN/TR 12566-5, Male čistilne naprave do 50 PE – 5. del: Filtrirne naprave za predčiščene hišne
odpadne vode
Skladno z notranjimi predpisi CEN/CENELEC morajo ta evropski standard prevzeti nacionalne
organizacije za standarde naslednjih držav: Avstrije, Belgije, Bolgarije, Cipra, Češke republike, Danske,
Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.
SIST EN 12566-6 : 2013
Legenda:
A surova gospodinjska odpadna voda 1 predizdelana greznica
B odpadna voda iz greznice 2 sistem za infiltracijo v tla
C očiščena infiltrirana odpadna voda 3 predizdelana in/ali na mestu vgradnje
sestavljena čistilna naprava za
D očiščena odpadna voda
gospodinjsko odpadno vodo
E terciarno očiščena odpadna voda
4 montažna greznica, sestavljena na mestu
vgradnje
5 filtrirni sistem za predčiščeno odpadno vodo
6 predizdelana čistilna enota za odpadno vodo iz
greznice
7 predizdelana terciarna čistilna enota

Slika 1: Shema ureditve delov standarda EN 12566

OPOMBA: Nacionalni predpisi lahko določajo drugačne razporeditve med proizvodi, opisanimi v standardih skupine EN
12566.
SIST EN 12566-6 : 2013
1 Področje uporabe
Ta evropski standard določa zahteve, preskusne metode, vrednotenje skladnosti in označevanje
predizdelanih sekundarnih čistilnih enot, ki se uporabljajo pri čiščenju odpadne vode iz greznice v skladu
z EN 12566-1 ali EN 12566-4 v malih čistilnih napravah do 50 PE.
OPOMBA: Iz obstoječih greznic lahko izhaja enakovredna odpadna voda.
Uporablja se za predizdelane sekundarne čistilne enote, ki imajo vse dele predizdelane ali izdelane za
vgradnjo na mestu in so na trgu na voljo kot kompleti enega proizvajalca.
Predizdelana sekundarna čistilna enota je sestavljena iz enega ali več rezervoarjev, izdelanih iz betona,
jekla, neplastificiranega polivinilklorida (PVC-U), polietilena (PE), s steklom ojačenega poliestra (GRP-
UP), polipropilena (PP), polidiciklopentadiena (PDCPD), ali iz posode, izdelane iz hidroizolacijskih
trakov (PEHD, PP, PVC, EPDM). Drugi deli, ki jih navede proizvajalec (npr. cevi, črpalke in material
filtra), so obravnavani kot del enote.
Ta standard določa delovanje predizdelanih sekundarnih čistilnih enot, ki je potrebno za preverjanje
njihove primernosti za končno uporabo v pogojih, za katere so določene preskusne metode.
Ta standard se uporablja za sekundarne čistilne enote, ki so predizdelane in/ali izdelane za sestavljanje
na mestu vgradnje ter se uporabljajo nad površino (zunaj stavbe) ali so zakopane pod površino, kjer ni
vozil, ki obremenjujejo enoto.
Ta standard ne zajema:
– nevodotesnih sekundarnih čistilnih enot z neposredno infiltracijo v tla,
– kompletov za rekonstrukcijo (glej definicijo v 3.7).
2 Zveze s standardi
Za uporabo tega dokumenta so, delno ali v celoti, nujni naslednji referenčni dokumenti. Pri datiranih
sklicevanjih se uporablja samo navedena izdaja. Pri nedatiranih sklicevanjih se uporablja zadnja izdaja
referenčnega dokumenta (vključno z morebitnimi dopolnili).
EN 1085:2007 Čiščenje odpadne vode – Slovar
EN 12566-1 Male čistilne naprave do 50 PE – 1. del: Predizdelane greznice
EN 12566-3:2005+A1:2009 Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake
EN 12566-4 Male čistilne naprave do 50 PE – 4. del: Montažne greznice, sestavljene na
mestu vgradnje
EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni
in elastomerni trakovi za tesnjenje streh
EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj
EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine
EN ISO 527-1 Polimerni materiali – Ugotavljanje nateznih lastnosti – 1. del: Splošna načela
(ISO 527-1)
EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)
EN ISO 7899-1 Kakovost vode – Ugotavljanje prisotnosti in števila intestinalnih
enterokokov v površinskih in odpadnih vodah – 1. del: Metoda z
miniaturizacijo (najbolj verjetno število) z nasajanjem v tekočem gojišču
(ISO 7899-1)
SIST EN 12566-6 : 2013
EN ISO 7899-2 Kakovost vode – Ugotavljanje prisotnosti in števila intestinalnih
enterokokov – 2. del: Metoda membranske filtracije (ISO 7899-2)
EN ISO 9308-1 Kakovost vode – Ugotavljanje prisotnosti in števila Escherichia coli in
koliformnih bakterij – 1. del: Metoda membranske filtracije (ISO 9308-1)
EN ISO 9308-3 Kakovost vode – Ugotavljanje prisotnosti in števila Escherichia coli in
koliformnih bakterij v površinski in odpadnih vodah – 3. del: Metoda z
miniaturizacijo (najbolj verjetno število) z nasajanjem v tekočem gojišču
(ISO 9308-3)
3 Izrazi in definicije
V tem dokumentu se uporabljajo izrazi in definicije, navedeni v EN 12566-3:2005+A1:2009 in EN
1085:2007, ter naslednji izrazi in definicije:
3.1
predizdelana sekundarna čistilna enota
tovarniško predizdelana enota, ki prečisti odpadno vodo iz greznice do navedene kakovosti
3.2
na mestu vgradnje sestavljena sekundarna čistilna enota
enota za čiščenje odpadne vode iz greznice do navedene kakovosti, ki jo zagotovi en proizvajalec in je
sestavljena na mestu vgradnje iz predizdelanih sestavnih delov
3.3
odprta enota
predizdelana enota brez pokrova
3.4
nazivna oznaka
ustrezne vrednosti za navedeno dnevno organsko obremenitev, izraženo v kilogramih BPK (ali BPK ) na
5 7
dan, in za navedeni dnevni hidravlični pretok, izražen v kubičnih metrih odpadne vode iz greznice na dan
(Q )
N
3.5
skupina enot
skupina enot, ki jih je izdelal en proizvajalec in za katere rezultati preskusa za vsaj eno lastnost
katerekoli enote iz skupine veljajo za vse ostale enote v skupini
3.6
čistilna naprava za odpadno vodo
kombinacija enot (npr. greznica) in/ali proizvodov (npr. cevi, črpalke), potrebna za izgradnjo naprave za
čiščenje odpadne vode v skladu s sliko 1
3.7
komplet za rekonstrukcijo
niz sestavnih delov, ki jih en proizvajalec zagotovi za vgradnjo v obstoječo greznico
3.8
hidroizolacijski trak
prilagodljiva neprepustna obloga
4 Simboli in kratice
V tem standardu se uporabljajo naslednji simboli in kratice:
BPK (ali BPK ) biokemijska potreba po kisiku po 5 ali 7 dneh
5 7
KPK kemijska potreba po kisiku
KN dušik po Kjeldahlu
SIST EN 12566-6 : 2013
NH4-N amonijev dušik
NS neraztopljene snovi
TOC celotni organski ogljik
5 Nazivna oznaka
Vsaka predizdelana sekundarna čistilna enota mora biti označena glede na:
– nazivno dnevno organsko obremenitev z odpadno vodo iz greznice, izraženo v kg BPK (ali BPK )
5 7
na dan, in
– nazivni dnevni hidravlični pretok Q , izražen v kubičnih metrih odpadne vode iz greznice na dan,
N
ter navedbo ustreznih vrednosti.
OPOMBA: Izbira proizvoda z nazivno oznako. Odvisno od vrste pogojev končne uporabe predizdelane sekundarne čistilne
enote (tj. vgradnje v gospodinjstvih, gostiščih, podjetjih itd.) in predpisov v kraju predvidene uporabe, je morda
treba pri izbiri nazivne oznake enote za skupino proizvodov upoštevati vsaj eno od naslednjih meril projektiranja:
– velikost greznice (v skladu z EN 12566-1 ali EN 12566-4) v povezavi s celotno obremenitvijo prebivalstva;
– navedeno vrednost usedanja neraztopljenih snovi (v gramih kroglic).
6 Zahteve
6.1 Projektiranje
6.1.1 Splošno
Predizdelane sekundarne čistilne enote za odpadno vodo iz greznice morajo imeti stabilno konstrukcijo
in prenesti pričakovane obremenitve v okviru predvidene uporabe. Poleg tega morajo biti enote trajne,
vodotesne in odporne proti koroziji. Določiti je treba pravila, ki zagotavljajo, da rezultati preskusa za eno
ali več lastnosti katerekoli enote iz skupine veljajo za vse ostale enote v tej skupini.
Enote morajo biti opremljene z alarmnim sistemom, ki opozarja na odpoved delovanja (npr. električne,
mehanske ali hidravlične odpovedi), kjer je to primerno. Navesti je treba vrste odpovedi, ki jih zazna
alarm.
Pri zasnovi enote naj se upoštevajo ustrezne varnostne zahteve za gradnjo, namestitev, obratovanje in
vzdrževanje.
6.1.2 Skupne dimenzije
Skupne dimenzije predizdelane sekundarne čistilne enote (npr. višina, širina, dolžina, premeri itd.)
morajo biti izmerjene in navedene skupaj s tolerancami.
Skupne dimenzije morajo biti ocenjene z meritvami s točnostjo ±0,5 % pri posamezni dimenziji.
6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki
Navesti je treba nazivne premere vtočnih in iztočnih cevi predizdelane sekundarne čistilne enote.
Hidravlična zasnova enote, notranji cevovod in priključki morajo preprečevati kakršnekoli povratne
tokove, zamašitve ali preobremenitve pri običajnem obratovanju enote.
Vtočne in iztočne cevi morajo biti združljive s standardiziranimi cevnimi sistemi.
Dimenzije vtočnih in iztočnih cevi, notranjega cevovoda in priključkov morajo biti ocenjene z meritvami
s točnostjo ±0,5 % pri posamezni dimenziji.

SIST EN 12566-6 : 2013
6.1.4 Dostop
Predizdelana sekundarna čistilna enota mora biti projektirana tako, da onemogoča nepooblaščen
dostop (npr. z zaklepnim mehanizmom).
Zasnova enote mora omogočati dostop za potrebe rednega vzdrževalnega vzorčenja, odvzemanja blata
(kjer je to primerno) ter čiščenja in vzdrževanja. Na voljo mora biti odprtina z dimenzijo (tj. širina pri
pravokotni površini ali premer pri krožni površini) vsaj 400 mm. Odprtina za dostop pri odprti enoti ni
potrebna.
OPOMBA 1: Za namestitev odprtih enot lahko veljajo lokalni predpisi za dostop za vzdrževanje.
OPOMBA 2: Zahteve za zagotavljanje dostopa osebe v predizdelano sekundarno čistilno enoto so lahko odvisne od veljavnih
predpisov, ki urejajo pogoje predvidene končne uporabe enote v posamezni državi članici, na primer najmanjša
dolžina odprtine za dostop osebe v skladu z EN 476 je 600 mm.
Jaški (kjer je to primerno) in pokrovi predizdelanih sekundarnih čistilnih enot za dostop morajo biti
zasnovani za svoj namen.
Navesti je treba dimenzije odprtin za dostop. Dimenzije odprtin za dostop je treba oceniti z meritvami s
točnostjo 0,5 % pri posamezni dimenziji.
6.2 Obremenitvena zmogljivost
6.2.1 Splošno
Za enote, ki ne vključujejo rezervoarja, ocena obremenitvene zmogljivosti ni zahtevana.
Preskusne metode in vrednosti za mehanske lastnosti materialov rezervoarja, ki se uporabljajo za izračun
obremenitvene zmogljivosti rezervoarja, morajo biti v skladu z EN 12566-3:2005+A1:2009, dodatek C.
Predizdelane sekundarne čistilne enote morajo v svoji predvideni življenjski dobi prenesti obremenitve,
ki so posledica obratovanja, vgradnje in uporabe, vključno z odvzemanjem blata in vzdrževanjem.
Za zakopane naprave je treba določiti obremenitveno zmogljivost predizdelane sekundarne čistilne
enote (tj. njenega rezervoarja):
– z izračunom ob poznavanju osnovnih podatkov za material in obremenitve (glej 6.2.2)
ali
– s preskusom neposredno na rezervoarju, ki je del enote (glej 6.2.3).
Če predizdelana sekundarna čistilna enota vključuje vodotesni jašek in/ali je vgrajena na nivoju vodne
gladine, je treba upoštevati ustrezne obremenitve pri največji vgradni globini enote in opraviti ustrezne
preskuse ali izračune za določitev obremenitvene zmogljivosti enote.
Obremenitvena zmogljivost je opredeljena kot:
– največja dovoljena višina zasipa (m),
– možnost vgradnje enote na nivoju vodne gladine, izražena kot VLAŽNO ali SUHO.
Obremenitveno zmogljivost predizdelanih sekundarnih čistilnih enot, ki so predvidene samo za uporabo
kot nezakopane, je treba oceniti izključno z izračunom.
Za enoto z vsebnikom iz hidroizolacijskih trakov je treba uporabiti izključno preskus v jami.

SIST EN 12566-6 : 2013
6.2.2 Obremenitvena zmogljivost, določena z izračunom
6.2.2.1 Splošno
Uporabi se lahko ena od naslednjih dveh metod:
a) 1. metoda: posredna metoda, uporabna za vse materiale, z navedbo naslednjih parametrov:
1) geometrijski podatki enote: npr. debelina stene, razdalja med rebri, oblika,
2) lastnosti materialov in sestavnih delov: vsi parametri, podani v točki o trajnosti (6.6).
Proizvajalec mora v navodilih za vgradnjo navesti višino zasipa in možnost vgradnje enote na nivoju
vodne gladine (oznaka VLAŽNO ali SUHO).
OPOMBA: Proizvajalec lahko po potrebi vključi rezultate izračuna v skladu z računsko metodo, veljavno v kraju uporabe.
b) 2. metoda: neposredna navedba delovanja po ustreznem evrokodu:
1) Evrokod 2 za beton (kjer je to primerno),
2) Evrokod 3 za jeklo (kjer je to primerno).
Proizvajalec mora navesti rezultate izračuna v skladu z ustreznim evrokodom v obliki višine zasipa in
možnosti vgradnje enote na nivoju vodne gladine (oznaka VLAŽNO ali SUHO).
6.2.2.2 Obremenitve zasipa
Izračun obremenitev zasipa je treba opraviti v skladu z EN 12566-3:2005+A1:2009, 6.2.1.2.
6.2.2.3 Hidrostatične obremenitve
Izračunati je treba navpično in vodoravno komponento hidrostatičnih obremenitev v skladu z EN 12566-
3:2005+A1:2009, 6.2.1.3.
6.2.2.4 Obremenitev pešcev
Če je višina zasipa (h) ≤ 1 m, je treba za obremenitve pešcev upoštevati vrednost 2,5 kN/m . Če je
višina zasipa več kot 1 m, se predvideva, da so obremenitve pešcev v primerjavi z drugimi
obremenitvami zanemarljive, zato jih ni treba upoštevati.
6.2.3 Obremenitvena zmogljivost, določena s preskušanjem
Obremenitveno zmogljivost predizdelane sekundarne čistilne enote je treba določiti na podlagi odpornosti
proti lomljenju ali deformacije pri največji obremenitvi v skladu z EN 12566-3:2005+A1:2009, dodatek C.
Z rezultati preskušanja je treba zagotoviti, da je obremenitvena zmogljivost v skladu z navedeno
obremenitvijo.
– Preskus odpornosti proti lomljenju (EN 12566-3:2005+A1:2009, C.2 in C.3): navedena vrednost
obremenitve mora biti manjša ali enaka vrednosti obremenitve ob odpovedi, deljeni s faktorjem
najmanj 1,6.
– Podtlačni preskus za enoto iz GRP (EN 12566-3:2005+A1:2009, C.5): enota mora zdržati zunanji
tlak za navedeno obremenitev, pomnoženo s faktorjem najmanj 1,5.
OPOMBA: Pri enačbi (C.2) v EN 12566-3:2005+A1:2009 je L obremenitev v kPa (navpična ali vodoravna obremenitev
zaradi zasipa in hidrostatična obremenitev, kar je večje).
– Preskus v jami (EN 12566-3:2005+A1:2009, C.6): enota mora biti vgrajena v skladu s proizvajalčevimi
navedbami za največjo določeno obremenitev.
Za odprto predizdelano sekundarno čistilno enoto je treba uporabiti izključno preskus v jami (glej primer
na sliki 2).
SIST EN 12566-6 : 2013
Za obremenitveno zmogljivost enote, izdelane iz polidiciklopentadiena, je treba uporabiti preskus v jami
v skladu z EN 12566-3:2005+A1:2009, C.6.

Legenda
 kot trenja:   63°
Slika 2: Preskus odprte enote v jami
6.3 Učinkovitost sekundarnega čiščenja
6.3.1 Splošno
Za ugotavljanje stopenj učinkovitosti sekundarnega čiščenja mora biti predizdelana sekundarna čistilna
enota preskušena v skladu z dodatkom A.
6.3.2 Stopnja učinkovitosti sekundarnega čiščenja
Predizdelana sekundarna čistilna enota mora biti skladna z navedenim delovanjem. To delovanje mora
biti izraženo in navedeno v obliki stopenj učinkovitosti sekundarnega čiščenja za kemijsko potrebo po
kisiku, biokemijsko potrebo po kisiku in koncentracije neraztopljenih snovi skupaj s podatki o:
– preskušeni dnevni obremenitvi vtoka za kemijsko potrebo po kisiku, biokemijsko potrebo po kisiku
in neraztopljene snovi ali
– lastnostih greznice (hidravlična učinkovitost, nazivna zmogljivost itd.), uporabljenih pri preskusu,
izraženih v skladu z EN 12566-1 ali EN 12566-4.
Preskušena dnevna obremenitev mora biti srednja vrednost 20-dnevnih obremenitev, izmerjenih v fazah
preskusa OSNOVNA, kot je opisano v dodatku A. V dokumentaciji je treba navesti stopnje učinkovitosti
sekundarnega čiščenja za kemijsko potrebo po kisiku, biokemijsko potrebo po kisiku in neraztopljene
snovi.
Po potrebi morajo biti v okviru preskusa analizirani dušikovi parametri in celotni fosfor. V tem primeru je
treba navesti tudi povezane stopnje učinkovitosti sekundarnega čiščenja.
Spremljajo in zabeležijo se lahko tudi drugi parametri, navedeni v A.1.4.
Za izračun posamezne stopnje učinkovitosti sekundarnega čiščenja je treba uporabiti naslednjo enačbo:
i o
P  P
ST
R 
i
P
kjer so:
R stopnja učinkovitosti sekundarnega čiščenja za podani parameter (npr. kemijska potreba po
ST
kisiku, biokemijska potreba po kisiku, neraztopljene snovi .)
P vrednost podanega parametra na vtoku predizdelane sekundarne čistilne enote
i
PO vrednost istega podanega parametra na iztoku predizdelane sekundarne čistilne enote
SIST EN 12566-6 : 2013
Katerakoli vrednost stopnje učinkovitosti sekundarnega čiščenja (RST), določena za podano dnevno
obremenitev, ne sme presegati srednje vrednosti stopnje učinkovitosti sekundarnega čiščenja,
pridobljene pri preskusu, opravljenem v skladu z dodatkom A.
Pridobljene vrednosti stopnje učinkovitosti sekundarnega čiščenja neposredno ne pomenijo, da so
predpisane zahteve za kakovost odpadne vode na določenem mestu uporabe izpolnjene. Opravi naj se
izračun, na podlagi katerega se določi končna kakovost odpadne vode, ki jo je treba primerjati z
zahtevami, veljavnimi v kraju predvidene uporabe enote. Te vrednosti stopnje se določijo v laboratoriju,
vendar jih ni mogoče vedno pridobiti, kadar je enota vgrajena na mestu uporabe.
6.3.3 Zmanjšanje količine prisotnih mikroorganizmov
Pri navedbi zmanjšanja količine prisotnih mikroorganizmov v predizdelani sekundarni čistilni enoti
morajo biti rezultati preskusov (tj. vrednosti vtoka in iztoka) izraženi v enotah (tj. cfu/100 ml ali MPN/100
ml). Zmanjšanje mora biti izraženo v logaritemski enoti. Vsi rezultati morajo biti podani v posebnem
dokumentu, kot je opisano v dodatku B.
Zabeleženo zmanjšanje prisotnosti mikroorganizmov neposredno ne pomeni, da so predpisane zahteve
za kakovost odpadne vode v določeni državi članici izpolnjene. Primerja naj se z zahtevami, veljavnimi
v kraju predvidene uporabe. Zmanjšanja prisotnosti mikroorganizmov ni mogoče vedno pridobiti, kadar
enota deluje v praksi.
6.4 Vodotesnost
Pri preskušanju v skladu z EN 12566-3:2005+A1:2009, dodatek A, morajo predizdelane sekundarne
čistilne enote za odpadno vodo iz greznice izpolnjevati zahteve za vodotesnost v skladu z EN 12566-
3:2005+A1:2009, 6.4.
Pri preskusu vodotesnosti enot z odprtim zgornjim delom je treba enoto napolniti do vrha.
Pri preskusu vodotesnosti enot, izdelanih iz polidiciklopentadiena, je treba upoštevati navodila v EN
12566-3:2005+A1:2009, A.2.
6.5 Poraba energije
Kjer je to primerno, morajo biti navedeni podatki o porabi energije enote.
Poraba energije mora biti izmerjena med preskusom, opisanim v dodatku A, in izražena kot poraba pri
običajnih obratovalnih pogojih (faza preskusa OSNOVNA) v kWh/d.
Navedena vrednost porabe energije mora biti večja ali enaka vrednosti, izmerjeni med preskusom iz
A.2.4.5.
Poraba energije mora biti ocenjena z meritvami s točnostjo ±5 % izmerjene vrednosti.
6.6 Trajnost
6.6.1 Splošno
Predizdelane sekundarne čistilne enote za odpadno vodo iz greznice, vključno z vsemi notranjimi
sestavnimi deli, morajo biti izdelane iz materialov, ki z vidika trajnosti zagotavljajo njihovo ustreznost za
uporabo v okolju gospodinjske odpadne vode.
Materiali drugih sestavnih delov enote (tj. material filtra, črpalka itd.) morajo biti v skladu s
specifikacijami, ki jih proizvajalec posreduje dobavitelju materialov/sestavnih delov.

SIST EN 12566-6 : 2013
6.6.2 Beton, jeklo, PVC-U, PE, GRP
Za rezervoar iz betona, jekla, PVC-U, PE, GRP (tj. za osnovni material in premaze, kjer je to primerno)
mora biti material v skladu z EN 12566-3:2005+A1:2009, 6.5.2 do 6.5.7, če je to primerno.
6.6.3 PDCPD
Polidiciklopentadien (PDCPD), oblikovan z injekcijskim brizganjem, ki se uporablja za enoto, mora imeti
naslednje lastnosti:
–3
a) viskoznost sestavnih delov A in B po Brookfieldu pred vbrizgavanjem: > 210 x 10 Pa·s pri (30 ± 1) °C
v skladu z EN ISO 2555;
b) gostota: več kot 1 000 kg/m pri (23 ± 2) °C;
c) natezne lastnosti, določene v skladu z EN ISO 527-1 (hitrost vlečenja = 50 mm/min):
1) E-modul: več kot 1 650 MPa,
2) obremenitev pri meji prožnosti: več kot 40 MPa,
3) raztezek pri meji prožnosti: več kot 3 %.
6.6.4 Hidroizolacijski trakovi
Lastnosti hidroizolacijskih trakov, uporabljenih za enoto, morajo biti v skladu s preglednico 1.
Preglednica 1: Lastnosti hidroizolacijskih trakov

Natezni preskus (kN/m)
Teža Prepustnost za tekočine
Material Debelina
2 pri raztezku 250 %
(g/m ) (EN 14150)
(EN 12311-2)
PEHD ≥ 1,5 mm > 1 400 ≥ 17 Skladno
PP ≥ 1 mm > 800 ≥ 5 Skladno
PVC ≥ 1 mm > 1 300 ≥ 7 Skladno
EPDM ≥ 1 mm > 1 400 ≥ 8 Skladno

6.7 Odziv na ogenj
6.7.1 Splošno
Kadar je uporaba predizdelane sekundarne čistilne enote predmet nacionalno predpisanih zahtev s
področja odziva na ogenj, je treba odziv na ogenj šteti za enega od sestavnih delov enote (tj. materialni
vidik) in mora biti naveden v obliki enega od naslednjih razredov v skladu z EN 13501-1:
a) razred A1 brez potrebe po preskušanju (CWT), kadar so izpolnjene zahteve, opredeljene v 6.7.2
ali kako drugače, ali
b) razred, določen skladno z rezultati preskušanja materiala(-ov), uporabljenega(-ih) v enoti, v skladu
s standardom(-i), navedenim(-i) v EN 13501-1, kot je določeno v 6.7.3.
OPOMBA 1: V večini primerov se šteje, da razred E zadostuje kot minimalna predpisana zahteva za odziv na ogenj pri
zakopanih (tj. podzemnih) enotah.
Če pa uporaba take enote ni predmet nacionalno predpisanih zahtev za odziv na ogenj, se lahko
navede katerikoli razred, določen v skladu z a) ali b), ali razred F (glej opombo 2).
OPOMBA 2: Razred F je v skladu z EN 13501-1 enakovreden možnosti "Lastnost ni določena" (NPD).

SIST EN 12566-6 : 2013
6.7.2 Enote, klasificirane kot razred A1, brez potrebe po preskušanju
1)
Odziv enote na ogenj mora biti naveden kot razred A1 brez potrebe po preskušanju pod naslednjimi
pogoji:
a) nobeden od sestavnih materialov, iz katerih je izdelan rezervoar enote, ne vsebuje več kot 1 %
homogeno porazdeljenega organskega materiala glede na maso ali prostornino (kar se zahteva) in
PRIMER: Montažni armirani beton, ki se uporablja za predizdelano sekundarno čistilno enoto, lahko na splošno vsebuje
organske materiale (npr. dodatke, aditive), če so uporabljeni, vendar je njihova vsebnost precej manjša od 1 %. Podobno se jeklo,
uporabljeno za enak namen, ne uporablja v fino zrnati obliki. Zaradi nizke ravni gorljivosti in pod opisanimi pogoji (glej opombo 1)
se lahko v zvezi z odzivom na ogenj oba materiala brez preskušanja obravnavata kot materiala razreda A1.
b) morebitni zunanji premaz, nanesen po površini rezervoarja, je izdelan iz anorganskega(-ih)
materiala(-ov) z debelino ≥ 1,0 mm ali maso na enoto površine ≥ 1,0 kg/m , ki je (so) ravno tako
klasificiran(-i) kot materiali razreda A1.
6.7.3 Enote, klasificirane v skladu z rezultati preskušanja
Z vidika odziva enote na ogenj morajo biti vsi sestavni materiali enote, vključno z materiali v njenem
površinskem premazu (če je uporabljen), klasificirani v skladu z EN 13501-1, pri čemer je treba navesti samo
najnižji razred teh materialov. Razred posameznega sestavnega materiala mora biti določen z rezultati
preskusne(-ih) metode (metod), ustreznimi za ta razred, in kot to določajo standardi, navedeni v EN
13501-1.
OPOMBA: Sestavni material enote se šteje za material, ki lahko pomembno vpliva na odziv take enote na ogenj. V skladu z
definicijami, podanimi v EN 13501-1, lahko to velja v naslednjih primerih:
– homogena enota: njen material ali
– nehomogena enota: njen bistveni sestavni del, tj. material, ki tvori pomemben del te enote. Sloj s površinsko
gostoto ≥ 1,0 kg/m ali debelino ≥ 1,0 mm se šteje za bistveni sestavni del.
PRIMER: Na splošno se lahko to obravnava kot pomembno za enoto, pri kateri je rezervoar izdelan iz vsaj enega od naslednjih
sestavnih materialov: nemehčani polivinilklorid (PVC-U), polietilen (PE), s steklom ojačeni poliester (GRP-UP), polipropilen (PP)
in polidiciklopentadien (PDCPD); ali je vsebnik izdelan iz hidroizolacijskih trakov (PEHD, PP, PVC, OR EPDM), s površinskim
premazom ali brez njega.
Preskusne vzorce, ki se uporabijo za preskusne metode, primerne za to klasifikacijo, je treba pripraviti
v skladu z EN 13501-1 in ustreznimi standardi, na katere se ta sklicuje.
6.8 Nevarne snovi
Nacionalni predpisi o nevarnih snoveh lahko zahtevajo preverjanje in izjavo o sprostitvi (včasih tudi o
vsebini), kadar so gradbeni proizvodi, zajeti v tem standardu, na voljo na teh trgih.
Če ni evropskih usklajenih preskusnih metod, je treba pri preverjanju in izjavi o sprostitvi/vsebini
upoštevati nacionalne predpise v kraju uporabe.
OPOMBA: Informativna baza podatkov evropskih in nacionalnih predpisov o nevarnih snoveh je na voljo na spletni strani
EUROPA - Construction na naslovu http://ec. europa. eu/enterprise/construction/cpd-ds/.
7 Vrednotenje skladnosti
7.1 Splošno
Skladnost predizdelane sekundarne čistilne enote z zahtevami tega standarda in z navedenimi
vrednostmi za navedene lastnosti (npr. vrednosti, razredi) je treba prikazati:
– z začetnim tipskim preskušanjem (ITT) in tipskim preskušanjem (TT), kjer se uporablja (glej 7.2);
– s kontrolo proizvodnje v obratu, ki jo opravi proizvajalec, vključno z oceno enote (glej 7.3).

1)
Glej Odločbo Komisije 96/603/ES 1996-10-04 (glej OJEU L 267 1996-10-19), kot je bila dvakrat spremenjena z
2000/605/ES 2000-09-26 (glej OJEU L 258 2000-10-12) in z 2003/424/ES 2003-06-06 (glej OJEU L 144 2003-06-12).
SIST EN 12566-6 : 2013
Proizvajalec mora vedno imeti nadzor in mora imeti potrebna sredstva, da prevzame odgovornost za
enoto.
7.2 Začetno tipsko preskušanje – tipsko preskušanje
7.2.1 Splošno
Za prikaz skladnosti predizdelane sekundarne čistilne enote z zahtevami tega evropskega standarda je
treba opraviti začetno tipsko preskušanje (ITT) in tipsko preskušanje (TT), kjer se uporablja.
Vse bistvene lastnosti, zapisane krepko v preglednici 2, za katere je treba navesti vrednosti za ustrezno
predvideno uporabo predizdelane sekundarne čistilne enote, morajo biti predmet začetnega tipskega
preskušanja.
OPOMBA 1: Začetno tipsko preskušanje navadno ni potrebno za lastnosti, katerih delovanje se v tem standardu nanaša na
naslednje primere/načine uporabe: predhodno obstoječi podatki, klasifikacija brez preskušanja (CWT) ali
klasifikacija brez nadaljnjega preskušanja (CWFT) ali po dogovoru sprejeta zmogljivost (CAP). Vendar, kadar so
podane nekatere zahteve za uporabo takega primera/načina uporabe (npr. klasifikacija brez nadaljnjega
preskušanja), se lahko začetno tipsko preskušanje omeji, da se izpolnijo te zahteve, z ustreznimi
preskusnimi/ocenjevalnimi metodami, opredeljenimi v tem dokumentu.
Poleg začetnega tipskega preskušanja je treba v okviru zagotavljanja skladnosti s tem standardom
opraviti tipske preskuse predizdelane sekundarne čistilne enote za vse druge lastnosti, ki jih vključuje
ta standard (glej preglednico 2).

SIST EN 12566-6 : 2013
Preglednica 2: Zahteve za začetne tipske preskuse predizdelanih sekundarnih čistilnih enot

Število
Točka z
Lastnost Ocenjevalna metoda preskusov/ Merila skladnosti
Št.
zahtevo
vz
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...