EN 12566-7:2013
(Main)Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units
Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units
This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit (see 3.9).
It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from:
a) units in accordance with EN 12566-3 or EN 12566-6;
b) installations designed and constructed in accordance with CEN/TR 12566-5.
Equivalent secondary treated effluent may come from existing systems.
Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD).
NOTE Some product covered by this standard sold without a tank could be introduced in an existing tank.
This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit.
This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6.
This standard does not cover the systems for micro-organism reduction.
Kleinkläranlagen für bis zu 50 EW - Teil 7: Vorgefertigte Anlagen für eine dritte Reinigungsstufe
Diese Europäische Norm legt Anforderungen, Prüfverfahren, die Kennzeichnung und die Konformitäts-bewertung für vorgefertigte und/oder vor Ort montierte Anlagen für eine dritte Reinigungsstufe fest, die entweder für den separaten Einbau oder den Einbau in eine bestehende Anlage (siehe 3.9) vorgesehen sind.
Sie gilt für als vollständige Produkte auf den Markt gebrachte Anlagen, die für eine dritte Reinigungsstufe von häuslichem Schmutzwasser durch biologische, physikalische, chemische oder elektrische Verfahren verwendet werden, das folgende Herkunft besitzt:
a) Anlagen nach EN 12566 3 oder EN 12566 6;
b) Anlagen, die nach CEN/TR 12566 5 konstruiert und gebaut wurden.
Gleichwertiges Abwasser der zweiten Reinigungsstufe kann aus bestehenden Anlagen stammen.
Vorgefertigte und/oder vor Ort montierte Anlagen für eine dritte Reinigungsstufe nach dieser Norm bestehen aus einem oder mehreren wasserdichten Behälter(n) ohne direkte Bodeninfiltration, hergestellt aus Beton, nichtrostendem oder beschichtetem Stahl, weichmacherfreiem Polyvinylchlorid (PVC U), Polyethylen (PE), glasfaserverstärktem duroplastischem Kunststoff (GFK) auf der Basis von Polyesterharz (UP) (GFK UP), Polypropylen (PP), Polydicyclopentadien (PDCPD) und flexiblen Bahnen (PEHD, PP; PVC und EPDM).
ANMERKUNG Einige in dieser Norm behandelte Produkte, die ohne Behälter verkauft werden, könnten in einen bereits vorhandenen Tank integriert werden.
Die vorliegende Norm gilt für Anlagen für eine dritte Reinigungsstufe, die für den Einsatz oberhalb des Bodens (außerhalb von Gebäuden) vorgesehen sind oder die in Stellen in den Boden eingebaut werden, an denen die Anlage keinen Fahrzeuglasten ausgesetzt ist.
Diese Norm gilt nicht für Anlagen für eine dritte Reinigungsstufe, die Teil von Anlagen nach EN 12566 3 und EN 12566 6 sind.
Diese Norm behandelt keine Anlagen zur Reduzierung von Mikroorganismen.
Petites installations de traitement des eaux usées jusqu'à 50 EH - Partie 7 : Unités de traitement tertiaire préfabriquées
La présente Norme européenne spécifie les exigences, les méthodes d’essai, le marquage et l’évaluation de la conformité d’une unité de traitement tertiaire prête à l’emploi et/ou assemblée sur site installée soit de façon distincte soit dans une unité pré-existante (voir 3.9).
Elle s’applique aux unités de traitement tertiaire introduites sur le marché en tant qu’unités complètes pour le traitement tertiaire des eaux usées domestiques par processus biologique, physique, chimique ou électrique provenant :
a) d’unités conformes à l’EN 12566-3 ou à l’EN 12566-6 ;
b) d’installations conçues et construites conformément au CEN/TR 12566-5.
Un effluent secondaire équivalent peut provenir de systèmes existants.
Conformément à la présente norme, les unités de traitement tertiaire prêtes à l’emploi ou assemblées sur site comprennent un ou plusieurs réservoirs étanches sans aucune infiltration directe dans le sol, fabriqués en béton, en acier résistant à la corrosion ou revêtu, en polychlorure de vinyle non plastifié (PVC-U), en polyéthylène (PE), en plastique renforcé à la fibre de verre (GRP) basé sur de la résine polyester (UP) (GRP-UP), en polypropylène (PP), en polydicyclopentadiène (PDCPD) et en membranes souples (PEHD, PP, PVE et EPDM).
NOTE Certains produits couverts par la présente norme et vendus sans réservoir peuvent être introduits dans un réservoir existant.
La présente norme s’applique aux unités de traitement tertiaire utilisées au-dessus du niveau du sol (à l’extérieur du bâtiment) ou enterrées à un emplacement où l’unité n’est pas soumise à des charges dues aux véhicules.
La présente norme ne s’applique pas aux systèmes de traitement tertiaire faisant partie d’unités visées par l’EN 12566-3 et l’EN 12566-6.
La présente norme ne couvre pas les systèmes de réduction des microorganismes.
Male čistilne naprave do 50 PE - 7. del: Predizdelane terciarne čistilne enote
Ta evropski standard podaja zahteve, preskusne metode, označevanje in ocenjevanje skladnosti za pakirane in/ali na kraju samem sestavljene terciarne čistilne enote za namestitev posebej ali v obstoječe rezervoarje (glej 3.9). Uporablja se za terciarne čistilne enote, ki so na trgu na voljo kot celotne enote za terciarno čiščenje odpadne vode z biološkimi, fizičnimi, kemičnimi in električnimi postopki in izhajajo iz: a) izdelkov, ki so v skladu s standardom EN 12566-3 ali EN 12566-6; b) naprav, ki so načrtovane in izdelane v skladu s standardom CEN/TR 12566-5. Embalaža in/ali na kraju samem sestavljene terciarne čistilne enote, ki so v skladu s tem standardom, so sestavljene iz enega ali več vodotesnih rezervoarjev brez infiltracije v zemljo in so izdelane iz betona, prevlečenega ali proti koroziji odpornega jekla, neplastificiranega polivinilklorida (PVC-U), polietilena (PE), s steklenimi vlakni ojačanih duromernih materialov (GRP) na osnovi nenasičene poliestrske smole (UP) (GRP-UP) in polipropilena (PP). Ta standard se uporablja za terciarne čistilne enote, ki se uporabljajo nad zemljo (pred stavbo) ali so zakopane pod zemljo, kjer ni vozil, ki obremenjujejo izdelek. Ta standard se ne uporablja za sestavne dele terciarnih čistilnih sistemov, ki so obravnavani v standardih EN 12566-3 in EN 12566-6. Ta standard ne obravnava sistemov za znižanje števila mikroorganizmov.
General Information
- Status
- Withdrawn
- Publication Date
- 16-Apr-2013
- Withdrawal Date
- 13-Apr-2025
- Technical Committee
- CEN/TC 165 - Waste water engineering
- Drafting Committee
- CEN/TC 165/WG 41 - Small type sewage treatment plants (< 50 inhabitants)
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 31-Aug-2016
- Completion Date
- 14-Apr-2025
- Directive
- 89/106/EEC - Construction products
Relations
- Effective Date
- 07-Sep-2016
Frequently Asked Questions
EN 12566-7:2013 is a standard published by the European Committee for Standardization (CEN). Its full title is "Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units". This standard covers: This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit (see 3.9). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD). NOTE Some product covered by this standard sold without a tank could be introduced in an existing tank. This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for micro-organism reduction.
This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit (see 3.9). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD). NOTE Some product covered by this standard sold without a tank could be introduced in an existing tank. This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for micro-organism reduction.
EN 12566-7:2013 is classified under the following ICS (International Classification for Standards) categories: 13.060.30 - Sewage water. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 12566-7:2013 has the following relationships with other standards: It is inter standard links to EN 12566-7:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 12566-7:2013 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/118. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 12566-7:2013 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kleinkläranlagen für bis zu 50 EW - Teil 7: Im Werk vorgefertigte Einheiten für eine dritte ReinigungsstufePetites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités de traitement tertiaire préfabriquéesSmall wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units13.060.30Odpadna vodaSewage waterICS:Ta slovenski standard je istoveten z:EN 12566-7:2013SIST EN 12566-7:2013en,de01-julij-2013SIST EN 12566-7:2013SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12566-7
April 2013 ICS 13.060.30 English Version
Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units
Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités de traitement tertiaire préfabriquées
Kleinkläranlagen für bis zu 50 EW - Teil 7: Vorgefertigte Anlagen für eine dritte Reinigungsstufe This European Standard was approved by CEN on 1 March 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12566-7:2013: ESIST EN 12566-7:2013
Tertiary treatment efficiency test procedure . 24 SIST EN 12566-7:2013
Definition of processes . 29 Annex C (informative)
Analysis method . 30 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 31 ZA.1 Scope and relevant characteristics . 31 ZA.2 Procedure of attestation of conformity of units . 33 ZA.2.1 System of attestation of conformity . 33 ZA.2.2 EC declaration of conformity . 35 ZA.3 CE marking . 36 Bibliography . 39
Figures Figure 1 — Scheme related to the arrangement of the parts of EN 12566 . 6 Figure 2 — Pit test for open unit . 13 Figure ZA.1 — Example CE marking information on the prefabricated tertiary treatment unit . 36 Figure ZA.2 — Example CE marking given in the commercial documents accompanying the prefabricated tertiary treatment unit when phosphorus removal . 38
Tables Table 1 — Characteristics of flexible sheets . 15 Table 2 — Requirements for initial type tests of the tertiary treatment units . 19 Table 3 — Minimum frequency of FPC testing for the tertiary treatment units . 22 Table A.1 — Daily flow pattern . 25 Table A.2 — Time test procedures . 26 Table A.3 — Definitions of overloads. 27 Table C.1 — Analysis methods . 30 Table ZA.1 — Scope and relevant characteristics . 32 Table ZA.2 — Attestation of conformity system . 33 Table ZA.3.1 — Assignment of evaluation of conformity tasks for prefabricated tertiary treatment units under system 3 +1 a . 34 SIST EN 12566-7:2013
Key A raw domestic wastewater 1 prefabricated septic tank B septic tank effluent 2 soil infiltration system C treated infiltrated effluent 3 packaged and/or site assembled domestic wastewater treatment plant D treated wastewater 4 septic tank assembled in situ from prefabricated kit E tertiary treated wastewater 5 pre-treated effluent filtration system
6 prefabricated treatment unit used for septic tank effluent
7 prefabricated tertiary treatment unit National regulations may specify different arrangements between the products described in the standard series EN 12566. Figure 1 — Scheme related to the arrangement of the parts of EN 12566 SIST EN 12566-7:2013
EN 12566-6:2013, EN 1085:2007 and the following apply. 3.1 tertiary treatment additional treatment process which results in further purification than that obtained by applying primary and secondary treatment Note 1 to entry: It is recommended that the expression for the treatment, e.g. nitrogen removal, phosphorus removal, polishing effects, suspended solid removal, is used since in some case the tertiary treatment can also be integrated in the secondary treatment. 3.2 packaged unit prefabricated factory-built unit 3.3 site assembled unit unit composed of prefabricated components assembled on site coming from one manufacturer 3.4 biological processes processes in which the treatment is mainly carried out by micro-organism activity 3.5 physical processes processes in which the treatment is mainly carried out by using the physical properties of a media 3.6 chemical processes processes in which the treatment is mainly carried out by the addition of chemical agents 3.7 electrical processes processes in which the treatment is mainly carried out by the use of electricity 3.8 unit family group of units produced by one manufacturer for which the test results for one or more characteristics from any one unit within the family are valid for all other units within this family Note 1 to entry: The definition of family could take into account at least similar shape, equipment, materials and conditions of end use. Note 2 to entry: The minimum level of performance is given by the test carried out on one unit of the family. 3.9 tertiary treatment retrofit unit tertiary treatment unit installed within an existing package and/or site assembled domestic wastewater treatment plant in accordance with EN 12566-3, or a secondary treatment unit in accordance with EN 12566-6 or a pre-treated effluent filtration system in accordance with CEN/TR 12566-5 Note 1 to entry: Where such a retrofit unit affects the declared performance of EN 12566-3 or EN 12566-6 unit in which it is installed, then the overall unit should be tested for its conformity with the relevant standard. 3.10
nominal designation appropriate values for parameters that represent the conditions for which the unit is designed by the manufacturer SIST EN 12566-7:2013
The requirements to provide facility for the access of a person into the prefabricated tertiary treatment unit may depend on applicable regulations, valid in the member state for the intended end use conditions. For example, the minimum dimension of the opening for the access of a person in EN 476 is 600 mm. Extension shafts, where applicable, and access covers of the prefabricated tertiary treatment unit shall be designed to be fit for purpose.
The access dimensions shall be declared. Assessment of access dimension shall be done by measurement with accuracy of 0,5 % of the dimension. 6.2 Load bearing capacity 6.2.1 General For units not including a tank, load bearing capacity assessment is not required. Test methods and values for mechanical characteristics of the materials of the tank, used for calculation of the load bearing capacity of the tank, shall be in accordance with EN 12566-3:2005+A1:2009, Annex C. The prefabricated tertiary treatment units shall resist the loads resulting from handling, installation and use including desludging and maintenance, for their design life. For buried installation, the load bearing capacity of the prefabricated tertiary treatment unit (i.e. of the tank of this unit) shall be established: either by calculation with the knowledge of basic data for material and loads (see 6.2.2); or by test directly on the tank of the unit (see 6.2.3). Where the prefabricated tertiary treatment unit includes watertight extension shaft, and/or the unit is installed in a water table, the relevant loads at the maximum installed depth of the unit shall be taken into account and appropriate tests or calculations made to prove the load bearing capacity of the unit. The load bearing capacity is declared as: maximum allowed height of backfill (m); possibility to install the unit in water table or not, expressed as WET with the indication of the maximum height of watertable measured from the base of the unit or DRY. The load bearing capacity of prefabricated tertiary treatment units that are intended to be used only in non buried conditions shall be assessed only by calculation. For a unit with the container made of flexible sheets, the pit test only shall be used. SIST EN 12566-7:2013
EN 12566-3:2005+A1:2009, 6.2.1.3. 6.2.2.4 Pedestrian loads For pedestrian loads a value of 2,5 N/m2 shall be considered in calculation only when the height of the backfill (h) is less than or equal to 1 m. Over 1 m, the pedestrian loads do not need to be taken into account for calculation, as it is assumed to be negligible against other loads. 6.2.3 Load bearing capacity determined by testing The load bearing capacity of the prefabricated tertiary treatment unit shall be established by the crushing resistance or maximum load deformation according to EN 12566-3:2005+A1:2009, Annex C. The test results shall ensure that the load bearing capacity under the declared load is ensured. Crushing resistance test (EN 12566-3:2005+A1:2009, C.2 and C.3): the declared load shall be lower or equal to the failure load divided by a factor of minimum 1,6. Vacuum test for GPR unit (EN 12566-3:2005+A1:2009, C.5): the unit shall withstand the external pressure for the declared load multiplied by a factor of minimum 1,5. NOTE In Formula (C.2) of EN 12566-3:2005+A1:2009, L is the load in kPa (the greater of the vertical or horizontal load due to backfill and hydrostatic load). SIST EN 12566-7:2013
is the total height of the plant (m); F is the crushing resistance (kN); H2 is the height of backfill (m). Vacuum test for GRP unit (EN 12566-3:2005+A1:2009, C.5): the height of backfill shall be calculated using the following formula: dSfPH×××=5,1 where S is the horizontal surface of the plant (m2); H
is the height of backfill (m); d is the specific weight of the backfill (kN/m3); P is the underpressure (MPa); f is the coefficient (see EN 12566-3:2005+A1:2009, 6.5). SIST EN 12566-7:2013
EN 12566-3:2005+A1:2009, C.6.
Key . friction angle ≤ 63° Figure 2 — Pit test for open unit 6.3 Tertiary treatment efficiency 6.3.1 General For the purpose of determination of the tertiary treatment efficiency the tertiary treatment unit shall be determined by testing in accordance with Annex A. If there is an effect of the tertiary treatment process on BOD5 or BOD7, COD and SS inlet concentrations, then that effect shall be declared. This may happen for retrofit unit or in case of recirculation. 6.3.2 Tertiary treatment efficiency ratio The tertiary treatment efficiency shall be expressed in terms of tertiary treatment efficiency ratios with the indication of the organic load tested and the parameter to be reduced. Each tertiary treatment efficiency ratio shall be calculated using the following formula: ioiTTPtPtPtR−= expressed in %; where RTT is the tertiary treatment efficiency ratio for a given parameter (e.g. BOD5 or BOD7, Total P, Total N); Pti is the figure of the given parameter at the inlet of the tertiary treatment unit; Pto is the figure of the same given parameter at the outlet of the tertiary treatment unit. The declared ratio measured at the tested daily load of the specified parameter shall not be greater than the ratio (mean value of efficiency ratios during nominal sequences) obtained by the test made according to Annex A. The recorded tertiary efficiency ratios do not automatically mean that the regulatory requirements on effluent qualities in a given Member State are met. A calculation should be made using the data given in the test SIST EN 12566-7:2013
6.7 Reaction to fire 6.7.1 General Where use of a prefabricated tertiary treatment unit is subject to national regulatory requirements on reaction to fire, its reaction to fire performance shall be considered as the one of its components (i.e. material approach) and shall be declared as one of the following classes, according to EN 13501-1: a) Class A1, without the need for testing (CWT), when meeting the requirements, specified in 6.7.2, or otherwise, or b) class, defined according to the results of testing of the material(s) used in the unit, according to the standard(s) referred to in EN 13501-1, as specified in 6.7.3. NOTE 1
In most cases Class E is considered to be sufficient as a minimum regulatory requirement for the reaction to fire performance of units used in buried (i.e. underground) applications. Conversely, where use of such a unit is not subject to national regulatory requirements on reaction to fire, either class, determined according to a) or b) or Class F (see NOTE 2) may be declared. NOTE 2 Class F according to EN 13501-1 is equivalent to "No Performance Determined" (NPD).
6.7.2 Units classified as Class A1 without the need for testing The reaction to fire performance of a unit shall be declared as Class A11) without the need for testing, provided that: a) each of the constituent materials that the tank of the unit is made of, contains not more than 1 % of homogeneously distributed organic material, by mass or volume (whichever is the most onerous), and EXAMPLE In general, precast reinforced concrete used for prefabricated tertiary treatment unit might contain organic materials (e.g. admixtures, additives) if any, but their level is far below 1 %. Similarly also steel, used for the same purpose, is not used in a finely divided form. Thus, on account of their low level of combustibility and subject to the conditions set out (see Footnote 1)) both materials might be considered, without testing, as class A1 materials for their reaction to fire performance.
1) See Decision of the Commission 96/603/EC of 1996-10-04 (see OJEU L 267 of 1996-10-19), as twice amended by 2000/605/EC of 2000-09-26 (see OJEU L 258 of 2000-10-12) and by 2003/424/EC of 2003-06-06 (see OJEU L 144 of 2003-06-12). SIST EN 12566-7:2013
In general, this might be considered relevant for the unit where the tank is made from one or more of the following constituent materials: unplasticised polyvinylchloride (PVC-U), polyethylene (PE), glass reinforced polyester (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD); or the container is made from flexible sheets (PEHD, PP, PVC, OR EPDM), with or without surface coating. Test specimens used for the test methods, applicable for this classification, shall be prepared according to EN 13501-1 and to the relevant standards referred therein. 6.8 Dangerous substances National regulations on dangerous substances may require verification and declaration on release, and sometimes content, when construction products covered by this standard are placed on those markets. In the absence of European harmonised test methods, verification and declaration on release/content should be done taking into account national provisions in the place of use. NOTE An informative database covering European and national provisions on dangerous substances is available at the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/. 7 Marking 7.1 Marking of the unit Each prefabricated tertiary treatment unit, complying with this standard, shall be marked with the following information: a) manufacturer and product identification; b) the number of this standard: i.e. EN 12566-7; c) type of material used for the tank where applicable; d) nominal designation; e) date of manufacture. Where regulatory marking provisions require information on some or all items listed in this clause, the requirements of this clause concerning those common items are deemed to be met. SIST EN 12566-7:2013
NOTE 1 These scaling rules are drafted under the responsibility of the manufacturer; this will be used to show the validity of the product selection for the ITT. e) information on the characteristics of the prefabricated tertiary treatment unit: 1) nominal designation of the tertiary treatment unit (see Clause 5); NOTE 2 This information could be accompanied by the equivalence in terms of total population (PT) in the place of intended use of the unit. 2) tertiary treatment efficiency ratios with the indication of the load tested, the parameter to be reduced and the range of ambient air temperature during the test; 3) power consumption of the unit in normal operating conditions (nominal sequences) if applicable; 4) watertightness; 5) load bearing capacity expressed as: i) maximum allowed height of backfill (m); ii) possibility to install the product in a water table or not, expressed as WET or DRY, respectively; NOTE 3 The method of determination of this characteristic is given (i.e. calculation or testing) according to the tank material. 6) durability; f) if there is an effect of the terti
...
SLOVENSKI SIST EN 12566-7
STANDARD
julij 2013
Male čistilne naprave do 50 PE –
7. del: Predizdelane terciarne čistilne enote
Small wastewater treatment systems for up to 50 PT –
Part 7: Prefabricated tertiary treatment units
Petites installations de traitement des eaux usées jusqu'à 50 PTE –
Partie 7: Unités de traitement tertiaire préfabriquées
Kleinkläranlagen für bis zu 50 EW –
Teil 7: Im Werk vorgefertigte Einheiten für eine dritte Reinigungsstufe
Referenčna oznaka
ICS 13.060.30 SIST EN 12566-7:2013 (sl)
Nadaljevanje na straneh II in III ter od 1 do 37
© 2016-05. Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 12566-7 : 2013
NACIONALNI UVOD
Standard SIST EN 12566-7 (sl), Male čistilne naprave do 50 PE – 7. del: Predizdelane terciarne čistilne
enote, 2013, ima status slovenskega standarda in je istoveten evropskemu standardu EN 12566-7 (en,
de, fr), Small wastewater treatment systems for up to 50 PT – Part 7: Prefabricated tertiary treatment
units, 2013.
NACIONALNI PREDGOVOR
Evropski standard EN 12566-7:2013 je pripravil tehnični odbor Evropskega komiteja za standardizacijo
CEN/TC 165 Odvajanje in čiščenje odpadne vode. Slovenski standard SIST EN 12566-7:2013 je prevod
evropskega standarda EN 12566-7:2013. V primeru spora glede besedila slovenskega prevoda v tem
standardu je odločilen izvirni evropski standard v enem izmed treh uradnih jezikov CEN. Slovensko
izdajo standarda je potrdil Strokovni svet SIST za splošno področje.
Odločitev za izdajo tega standarda je oktobra 2012 sprejel Strokovni svet SIST za splošno področje.
ZVEZA S STANDARDI
S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST EN 1085:2007 Čiščenje odpadne vode – Slovar
SIST EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni
in elastomerni trakovi za tesnjenje streh
SIST EN 12566-3:2005+A1:2009 Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake
SIST EN 12566-6:2013 Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za obdelavo
grezničnih odplak
SIST EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj
SIST EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine
SIST EN ISO 527 (vsi deli) Polimerni materiali – Določanje nateznih lastnosti (ISO 527)
SIST EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)
OSNOVA ZA IZDAJO STANDARDA
– privzem standarda EN 12566-7:2013
OPOMBE
– Povsod, kjer se v besedilu standarda uporablja izraz “evropski standard”, v SIST EN 12566-7:2013
to pomeni “slovenski standard”.
– Uvod in nacionalni predgovor nista sestavni del standarda.
II
SIST EN 12566-7 : 2013
– Ta nacionalni dokument je istoveten EN 12566-7:2013 in je objavljen z dovoljenjem
CEN
Upravni center
Avenue Marnix 17
B-1000 Bruselj
This national document is identical with EN 12566-7:2013 and is published with the permission of
CEN
Management Centre
Avenue Marnix 17
B-1000 Brussels
III
EVROPSKI STANDARD EN ISO 12566-7
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM april 2013
ICS 13.060.30
Slovenska izdaja
Male čistilne naprave do 50 PE –
7. del: Predizdelane terciarne čistilne enote
Small wastewater treatment Petites installations de traitement des Kleinkläranlagen für bis zu 50 EW
systems for up to 50 PT – eaux usées jusqu'à 50 PTE – – Teil 7: Im Werk vorgefertigte
Part 7: Prefabricated tertiary Partie 7: Unités de traitement tertiaire Einheiten für eine dritte
treatment units préfabriquées Reinigungsstufe
Ta evropski standard je CEN sprejel dne 1. marca 2013.
Člani CEN morajo izpolnjevati določila notranjih predpisov CEN/CENELEC, s katerimi je predpisano, da
mora biti ta evropski standard brez kakršnih koli sprememb sprejet kot nacionalni standard. Seznami
najnovejših izdaj teh nacionalnih standardov in njihovi bibliografski podatki so na voljo pri Upravnem
centru CEN-CENELEC ali članih CEN.
Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski in nemški). Izdaje v drugih
jezikih, ki jih člani CEN na lastno odgovornost prevedejo in izdajo ter prijavijo pri upravnem centru
CEN-CENELEC, veljajo kot uradne izdaje.
Člani CEN so nacionalni organi za standarde Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.
CEN
Evropski komite za standardizacijo
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung
Upravni center: Avenue Marnix, 17, B-1050 Brussels
© 2013 CEN. Lastnice avtorskih pravic so vse države članice CEN Ref. oznaka: EN ISO 12566-7:2013 E
SIST EN 12566-7 : 2013
VSEBINA Stran
Predgovor . 4
1 Področje uporabe . 6
2 Zveze s standardi . 6
3 Izrazi in definicije . 7
4 Simboli in kratice . 8
5 Nazivna oznaka . 8
6 Zahteve . 8
6.1 Projektiranje . 8
6.1.1 Splošno . 8
6.1.2 Skupne dimenzije . 8
6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki . 8
6.1.4 Dostop . 8
6.2 Obremenitvena zmogljivost . 9
6.2.1 Splošno . 9
6.2.2 Obremenitvena zmogljivost, določena z izračunom . 9
6.2.3 Obremenitvena zmogljivost, določena s preskušanjem . 10
6.3 Učinkovitost terciarnega čiščenja . 12
6.3.1 Splošno . 12
6.3.2 Stopnja učinkovitosti terciarnega čiščenja . 12
6.4 Vodotesnost . 12
6.5 Poraba energije . 13
6.6 Trajnost . 13
6.6.1 Splošno . 13
6.6.2 Beton, jeklo, PVC-U, PE, GRP . 13
6.6.3 PDCPD . 13
6.6.4 Hidroizolacijski trakovi . 13
6.7 Odziv na ogenj . 14
6.7.1 Splošno . 14
6.7.2 Enote, klasificirane kot razred A1, brez potrebe po preskušanju . 14
6.7.3 Enote, klasificirane v skladu z rezultati preskušanja . 14
6.8 Nevarne snovi . 15
7 Označevanje . 15
7.1 Označevanje enote . 15
7.2 Enoti priložene tehnične informacije, . 15
8 Vrednotenje skladnosti . 16
8.1 Splošno . 16
8.2 Začetno tipsko preskušanje – tipsko preskušanje . 16
8.2.1 Splošno . 16
8.2.2 Vzorčenje, preskušanje in merila skladnosti . 19
SIST EN 12566-7 : 2013
8.2.3 Poročila o preskusih . 19
8.3 Kontrola proizvodnje v obratu (FPC) . 19
8.3.1 Splošno . 19
8.3.2 Zahteve . 19
8.3.3 Postopek za spremembe . 21
8.3.4 Začetni pregled obrata in kontrole proizvodnje v obratu . 22
8.3.5 Stalni nadzor nad kontrolo proizvodnje v obratu . 22
9 Navodila za vgradnjo . 22
10 Priročnik o obratovanju . 22
Dodatek A (normativni): Postopek preskusa učinkovitosti terciarnega čiščenja . 23
Dodatek B (normativni): Definicija procesov . 27
Dodatek C (informativni): Analizna metoda . 28
Dodatek ZA (informativni): Točke tega evropskega standarda, ki se nanašajo na določila
Direktive EU o gradbenih proizvodih . 29
Literatura. 37
SIST EN 12566-7 : 2013
Predgovor
Ta dokument (EN 12566-7:2013) je pripravil tehnični odbor CEN/TC 165 Odvajanje in čiščenje odpadne
vode, katerega sekretariat vodi DIN.
Ta evropski standard mora dobiti status nacionalnega standarda z objavo istovetnega besedila ali z
razglasitvijo najpozneje do oktobra 2013. Do istega roka je treba umakniti tudi nacionalne standarde, ki
so v nasprotju s tem standardom.
Opozoriti je treba na možnost, da so lahko nekateri elementi tega dokumenta predmet patentnih pravic.
CEN [in/ali CENELEC] ne prevzema odgovornosti za identifikacijo nekaterih ali vseh takih patentnih
pravic.
Ta dokument je bil pripravljen na podlagi mandata, ki sta ga Evropska komisija in Evropsko združenje
za prosto trgovino podelila CEN, in podpira bistvene zahteve direktive (direktiv) EU.
Za povezavo z direktivami Evropske unije glej dodatek ZA, ki je sestavni del tega dokumenta.
Skupina standardov EN 12566, Male čistilne naprave do 50 PE, vključuje naslednje dele (glej sliko 1):
– 1. del: Predizdelane greznice
– 3. del: Predizdelane in/ali na mestu postavitve sestavljene čistilne naprave za gospodinjske
odplake
– 4. del: Montažne greznice, sestavljene na mestu vgradnje
– 6. del: Predizdelane enote za obdelavo grezničnih odplak
– 7. del: Predizdelane terciarne čistilne enote (ta dokument)
Za sisteme za filtriranje in infiltracijo je CEN/TC 165 objavil naslednji tehnični poročili CEN, ki se
upoštevata kot pravila ravnanja in ne določata zahtev za čiščenje:
– CEN/TR 12566-2, Male čistilne naprave do 50 PE – 2. del: Sistemi za infiltracijo v zemljo
– CEN/TR 12566-5, Male čistilne naprave do 50 PE – 5. del: Filtrirne naprave za predčiščene hišne
odpadne vode
Ta evropski standard določa splošne zahteve za predizdelane in/ali na mestu postavitve sestavljene
terciarne čistilne naprave za čiščenje sekundarne odpadne vode.
V skladu z notranjimi predpisi CEN-CENELEC morajo ta evropski standard obvezno uvesti nacionalne
organizacije za standardizacijo naslednjih držav: Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Hrvaške, Irske, Islandije, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nekdanje jugoslovanske republike Makedonije, Nemčije, Nizozemske, Norveške,
Poljske, Portugalske, Romunije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in Združenega
kraljestva.
SIST EN 12566-7 : 2013
Legenda:
A surova gospodinjska odpadna voda 1 predizdelana greznica
B odpadna voda iz greznice 2 sistem za infiltracijo v tla
C očiščena infiltrirana odpadna voda 3 predizdelana in/ali na mestu vgradnje sestavljena čistilna
naprava za gospodinjsko odpadno vodo
D očiščena odpadna voda
4 montažna greznica, sestavljena na mestu vgradnje
E terciarno očiščena odpadna voda
5 filtrirni sistem za predčiščeno odpadno vodo
6 predizdelana čistilna enota za odpadno vodo iz greznice
7 predizdelana terciarna čistilna enota
Nacionalni predpisi lahko določajo drugačne razporeditve med proizvodi, opisanimi v standardih skupine
EN 12566.
Slika 1: Shema, povezana z razporeditvijo delov standarda EN 12566
SIST EN 12566-7 : 2013
1 Področje uporabe
Ta evropski standard določa zahteve, preskusne metode, označevanje in vrednotenje skladnosti
predizdelanih in/ali na mestu postavitve sestavljenih terciarnih čistilnih enot za namestitev posebej ali v
obstoječe enote (glej 3.9).
Uporablja se za terciarne čistilne enote, ki so na trgu na voljo kot kompletne enote za terciarno čiščenje
gospodinjske odpadne vode z biološkimi, fizikalnimi, kemijskimi in električnimi postopki ter izhajajo:
a) iz enot v skladu s standardom EN 12566-3 ali EN 12566-6,
b) iz naprav, projektiranih in izdelanih v skladu s standardom CEN/TR 12566-5.
Enakovredne sekundarno očiščene odpadne vode lahko izhajajo iz obstoječih sistemov.
Predizdelane in/ali na mestu postavitve sestavljene terciarne čistilne enote, ki so v skladu s tem
standardom, so sestavljene iz enega ali več vodotesnih rezervoarjev brez neposredne infiltracije v tla in
izdelane iz betona, prevlečenega ali proti koroziji odpornega jekla, neplastificiranega polivinilklorida
(PVC-U), polietilena (PE), s steklenimi vlakni ojačenih duromernih materialov (GRP) na osnovi
nenasičene poliestrske smole (UP) (GRP-UP), polipropilena (PP), polidiciklopentadiena (PDCPD) ali
hidroizolacijskih trakov (PEHD, PP, PVE in EPDM).
OPOMBA: Nekateri izdelki, obravnavani v tem standardu, ki se prodajajo brez rezervoarja, se lahko uporabijo v povezavi z
obstoječim rezervoarjem.
Ta standard se uporablja za terciarne čistilne enote, ki se uporabljajo nad površino (zunaj stavb) ali so
zakopane pod površino, kjer niso izpostavljene obremenitvam vozil.
Ta standard se ne uporablja za sestavne dele terciarnih čistilnih naprav, ki so obravnavani v standardih
EN 12566-3 in EN 12566-6.
Ta standard ne obravnava sistemov za znižanje števila mikroorganizmov.
2 Zveze s standardi
Za uporabo tega dokumenta so, delno ali v celoti, nujni naslednji referenčni dokumenti. Pri datiranih
sklicevanjih se uporablja samo navedena izdaja. Pri nedatiranih sklicevanjih se uporablja zadnja izdaja
referenčnega dokumenta (vključno z morebitnimi dopolnili).
EN 1085:2007 Čiščenje odpadne vode – Slovar
EN 12311-2 Hidroizolacijski trakovi – Ugotavljanje nateznih lastnosti – 2. del: Polimerni
in elastomerni trakovi za tesnjenje streh
EN 12566-3:2005+A1:2009 Male čistilne naprave do 50 PE – 3. del: Predizdelane in/ali na mestu
postavitve sestavljene čistilne naprave za gospodinjske odplake
EN 12566-6:2013 Male čistilne naprave do 50 PE – 6. del: Predizdelane enote za obdelavo
grezničnih odplak
EN 13501-1 Požarna klasifikacija gradbenih proizvodov in elementov stavb – 1. del:
Klasifikacija po podatkih iz preskusov odziva na ogenj
EN 14150 Geosintetične ovire – Ugotavljanje prepustnosti za tekočine
EN ISO 527 (vsi deli) Polimerni materiali – Ugotavljanje nateznih lastnosti (ISO 527)
EN ISO 2555 Polimerni materiali – Tekoče smole, emulzije ali disperzije – Preskusna
metoda za določanje navidezne viskoznosti po Brookfieldu (ISO 2555)
SIST EN 12566-7 : 2013
3 Izrazi in definicije
V tem dokumentu se uporabljajo izrazi in definicije, navedeni v EN 12566-3:2005+A1:2009, EN 12566-
6:2013, EN 1085:2007, ter naslednji izrazi in definicije:
3.1
terciarno čiščenje
dodaten postopek čiščenja za dodatno čiščenje primarno in sekundarno očiščene odpadne vode
OPOMBA 1: Priporoča se uporaba izraza za čiščenje (npr. odstranjevanje dušika, odstranjevanje fosforja, učinki poliranja,
odstranjevanje neraztopljenih snovi), saj je v nekaterih primerih lahko postopek terciarnega čiščenja vključen v
postopek sekundarnega čiščenja.
3.2
predizdelana enota
tovarniško predizdelana enota
3.3
na mestu vgradnje sestavljena enota
enota, sestavljena na mestu vgradnje iz predizdelanih sestavnih delov istega proizvajalca
3.4
biološki procesi
procesi, v katerih se čiščenje izvaja v glavnem z dejavnostjo mikroorganizmov
3.5
fizikalni procesi
procesi, v katerih se čiščenje izvaja v glavnem z uporabo fizikalnih lastnosti medija
3.6
kemijski procesi
procesi, v katerih se čiščenje izvaja v glavnem z dodajanjem kemijskih sredstev
3.7
električni procesi
procesi, v katerih se čiščenje izvaja v glavnem z uporabo elektrike
3.8
skupina enot
skupina enot, ki jih je izdelal isti proizvajalec in za katere rezultati preskusa za vsaj eno lastnost
katerekoli enote iz skupine veljajo za vse ostale enote v skupini
OPOMBA 1: Definicija skupine lahko vključuje vsaj podobno obliko, opremo, materiale in pogoje končne uporabe.
OPOMBA 2: Najmanjša raven zmogljivosti se določi na podlagi preskusa ene od enot v skupini.
3.9
terciarna čistilna enota za rekonstrukcijo
terciarna čistilna enota, vgrajena v obstoječo predizdelano in/ali na mestu vgradnje sestavljeno čistilno
napravo za gospodinjsko odpadno vodo v skladu z EN 12566-3 ali sekundarna čistilna enota v skladu
z EN 12566-6 ali filtrirna naprava za predčiščeno gospodinjsko odpadno vodo v skladu s CEN/TR
12566-5
OPOMBA 1: Če enota za rekonstrukcijo vpliva na deklarirane lastnosti enote v skladu z EN 12566- 3 ali EN 12566-6, v katero je
vgrajena, je treba preskusiti celotno enoto in preveriti njeno skladnost z ustreznim standardom.
3.10
nazivna oznaka
ustrezne vrednosti parametrov, ki določajo pogoje, za katere je proizvajalec projektiral enoto
SIST EN 12566-7 : 2013
4 Simboli in kratice
BKP5 (ali BKP7) biokemijska potreba po kisiku po 5 (ali 7) dneh
KPK kemijska potreba po kisiku
NS neraztopljene snovi
celotni N celotni dušik
celotni P celotni fosfor
5 Nazivna oznaka
Nazivna oznaka terciarne čistilne enote mora biti navedena kot:
– dnevni hidravlični pretok Q N (m /d) v običajnih pogojih in
– (za parametre, predvidene za čiščenje) dnevna obremenitev enote v običajnih pogojih za navedene
parametre, tj. BKP5 in/ali BKP7 in/ali KPK in/ali neraztopljene snovi in/ali celotni fosfor in/ali celotni
dušik, izražen v kg/d.
PRIMER: 1,4 m /d in 0,02 kg/d za celotni fosfor.
6 Zahteve
6.1 Projektiranje
6.1.1 Splošno
Terciarne čistilne enote morajo imeti stabilno konstrukcijo in prenesti pričakovane obremenitve v okviru
predvidene uporabe. Poleg tega morajo biti enote trajne, vodotesne in odporne proti koroziji.
Kjer lahko električne, mehanske ali hidravlične okvare enote povzročijo morebitno odpoved, mora biti
enota opremljena z alarmom, ki opozarja na tovrstne odpovedi. Delovanje alarma mora biti preverjeno,
kot je navedeno v preglednici A.2.
6.1.2 Skupne dimenzije
Skupne dimenzije predizdelane terciarne čistilne enote (npr. višina, širina, dolžina, premeri itd.) morajo
biti izmerjene in navedene skupaj s tolerancami.
Skupne dimenzije morajo biti ocenjene z meritvami s točnostjo ±0,5 % pri posamezni dimenziji.
6.1.3 Vtočne in iztočne odprtine, notranji cevovod ter priključki
V tehnični dokumentaciji je treba navesti nazivne premere vtočnih in iztočnih cevi predizdelane terciarne
čistilne enote. Hidravlična zasnova enote, notranji cevovod in priključki morajo preprečevati kakršnekoli
naključne povratne tokove, zamašitve ali preobremenitve pri običajnem obratovanju enote.
Vtočne in iztočne cevi morajo biti združljive s standardiziranimi cevnimi sistemi.
Dimenzije vtočnih in iztočnih cevi, notranjega cevovoda in priključkov morajo biti ocenjene z meritvami
s točnostjo ±0,5 % pri posamezni dimenziji.
6.1.4 Dostop
Predizdelana terciarna čistilna enota mora biti projektirana tako, da onemogoča nepooblaščen dostop
(npr. z zaklepnim mehanizmom).
SIST EN 12566-7 : 2013
Zasnova enote mora omogočati dostop za potrebe rednega vzdrževalnega vzorčenja, odvzemanja blata
(kjer je to primerno) ter čiščenja in vzdrževanja. Na voljo mora biti odprtina z dimenzijo (tj. dolžina pri
pravokotni površini ali premer pri krožni površini) vsaj 400 mm. Dostopna odprtina pri odprti enoti ni
potrebna.
Za namestitve odprtih enot lahko obstajajo lokalni predpisi za dostop za vzdrževanje.
Zahteve za zagotavljanje dostopa osebe v predizdelano terciarno čistilno enoto so lahko odvisne od
veljavnih predpisov, ki urejajo pogoje predvidene končne uporabe enote v posamezni državi članici.
(npr. najmanjša dolžina odprtine za dostop osebe v skladu z EN 476 je 600 mm).
Dostopni jaški (kjer je to primerno) in dostopni pokrovi predizdelanih terciarnih čistilnih enot morajo biti
primerni za svoj namen.
Navesti je treba dimenzije dostopnih odprtin. Dimenzije dostopne odprtine morajo biti ocenjene z
meritvami s točnostjo 0,5 % pri posamezni dimenziji.
6.2 Obremenitvena zmogljivost
6.2.1 Splošno
Za enote, ki ne vključujejo rezervoarja, ocena obremenitvene zmogljivosti ni zahtevana.
Preskusne metode in vrednosti za mehanske lastnosti materialov rezervoarja, ki se uporabljajo za izračun
obremenitvene zmogljivosti rezervoarja, morajo biti v skladu z EN 12566-3:2005+A1:2009, dodatek C.
Predizdelane terciarne čistilne enote morajo v svoji predvideni življenjski dobi prenesti obremenitve, ki
so posledica obratovanja, vgradnje in uporabe, vključno z odvzemanjem blata in vzdrževanjem.
Za zakopane naprave je treba določiti obremenitveno zmogljivost predizdelane terciarne čistilne enote
(tj. njenega rezervoarja):
– z izračunom ob poznavanju osnovnih podatkov za material in obremenitve (glej 6.2.2)
– ali s preskusom neposredno na rezervoarju enote (glej 6.2.3).
Če predizdelana terciarna čistilna enota vključuje vodotesni jašek in/ali je vgrajena na nivoju vodne
gladine, je treba upoštevati ustrezne obremenitve pri največji vgradni globini enote in opraviti ustrezne
preskuse ali izračune za določitev obremenitvene zmogljivosti enote.
Obremenitvena zmogljivost je opredeljena kot:
– največja dovoljena višina zasipa (m),
– možnost vgradnje enote na nivoju vodne gladine z oznako VLAŽNO in navedbo največje višine
vodne gladine, izmerjene od dna enote, ali z oznako SUHO.
Obremenitveno zmogljivost predizdelanih terciarnih čistilnih enot, ki so predvidene samo za uporabo kot
nezakopane, je treba oceniti izključno z izračunom.
Za enoto z vsebnikom iz hidroizolacijskih trakov je treba uporabiti izključno preskus v jami.
6.2.2 Obremenitvena zmogljivost, določena z izračunom
6.2.2.1 Splošno
Uporabi se lahko ena od naslednjih dveh metod:
a) 1. metoda: posredna metoda, uporabna za vse materiale, z navedbo naslednjih parametrov:
1) geometrijski podatki enote: npr. debelina stene, razdalja med rebri, oblika itd.,
SIST EN 12566-7 : 2013
2) lastnosti materialov in sestavnih delov: vsi parametri, podani v točki o trajnosti (6.6).
Proizvajalec mora v navodilih za vgradnjo navesti višino zasipa in največjo višino vodne gladine za
vgradnjo.
b) 2. metoda: neposredna navedba učinkovitosti delovanja po ustreznem evrokodu:
1) Evrokod 2 za beton (kjer je to primerno);
2) Evrokod 3 za jeklo (kjer je to primerno).
Proizvajalec mora navesti rezultate izračuna v skladu z ustreznim evrokodom v obliki višine zasipa in
možnosti za namestitev naprave na suhem ali vlažnem mestu, pri čemer mora biti navedena višina
vodne gladine, izmerjena od dna naprave.
OPOMBA: Če se za oceno obremenitvene zmogljivosti uporabi 1. metoda, priglašeni organ preveri dimenzije izdelka in
lastnosti materiala. Če se uporabi 2. metoda, priglašeni organ preveri vhodne podatke za izračun, preveri izračun
in potrdi rezultate v poročilu o začetnem tipskem preskušanju.
6.2.2.2 Obremenitve zasipa
Izračun obremenitev zasipa je treba opraviti v skladu z EN 12566-3:2005+A1:2009, 6.2.1.2.
6.2.2.3 Hidrostatične obremenitve
Izračunati je treba navpično in vodoravno komponento hidrostatičnih obremenitev v skladu z EN 12566-
3:2005+A1:2009, 6.2.1.3.
6.2.2.4 Obremenitve pešcev
Če je višina zasipa (h) ≤ 1 m, je treba za obremenitve pešcev upoštevati vrednost 2,5 N/m . Če je višina
več kot 1 m, se predvideva, da so obremenitve pešcev v primerjavi z drugimi obremenitvami
zanemarljive, zato jih ni treba upoštevati.
6.2.3 Obremenitvena zmogljivost, določena s preskušanjem
Obremenitveno zmogljivost predizdelane terciarne čistilne enote je treba določiti na podlagi odpornosti
proti lomljenju ali deformacije pri največji obremenitvi v skladu z EN 12566-3:2005+A1:2009, dodatek
C.
Z rezultati preskušanja je treba zagotoviti, da je obremenitvena zmogljivost v skladu z navedeno
obremenitvijo.
– Preskus odpornosti proti lomljenju (EN 12566-3:2005+A1:2009, C.2 in C.3): navedena vrednost
obremenitve mora biti manjša ali enaka vrednosti obremenitve ob odpovedi, deljeni s faktorjem
najmanj 1,6.
– Podtlačni preskus za enoto GRP (EN 12566-3:2005+A1:2009, C.5): enota mora zdržati zunanji tlak
za navedeno obremenitev, pomnoženo s faktorjem najmanj 1,5.
OPOMBA: Pri enačbi (C.2) v EN 12566-3:2005+A1:2009 je L obremenitev v kPa (navpična ali vodoravna obremenitev
zaradi zasipa in hidrostatična obremenitev, kar je večje).
– Preskus v jami (EN 12566-3:2005+A1:2009, C.6): enota mora biti vgrajena v skladu s
proizvajalčevimi navedbami. Preskus odpornost proti lomljenju (EN 12566-3:2005+A1:2009, C.2.1
in C.2.2.2): višini zasipa morata biti najmanjši vrednosti H in H , izračunani s spodnjima enačbama.
1 2
Za navpično obremenitev:
kjer so:
SIST EN 12566-7 : 2013
F obremenitev lomljenja (kN)
S vodoravna površina naprave (m )
HW višina vodne gladine, izmerjena od dna naprave (m)
H višina zasipa (m)
Za vodoravno obremenitev:
kjer so:
K koeficient (glej 6.2.2.2)
F obremenitev lomljenja (kN)
S2 lateralna površina naprave (m )
H višina vodne gladine, izmerjena od dna naprave (m)
W
Hp skupna višina naprave (m)
F obremenitev lomljenja (kN)
H2 višina zasipa (m)
– Podtlačni preskus za enoto iz GRP (EN 12566-3:2005+A1:2009, C.5): višina zasipa mora biti
izračunana z naslednjo enačbo:
kjer so:
S vodoravna površina naprave (m )
H višina zasipa (m)
d specifična teža zasipa (kN/m )
P podtlak (MPa)
f koeficient (glej EN 12566-3:2005+A1:2009, 6.5)
– Preskus v jami (EN 12566-3:2005+A1:2009, C.6): enota mora biti nameščena v skladu s podatki o
največji višini zasipa in možnostmi za namestitev naprave na suhem ali vlažnem mestu (oznaka
SUHO ali VLAŽNO), ki jih navede proizvajalec.
Za odprto predizdelano terciarno čistilno enoto je treba uporabiti izključno preskus v jami (glej primer na
sliki 2).
Za obremenitveno zmogljivost enote, izdelane iz polidiciklopentadiena, je treba uporabiti preskus v jami
v skladu z EN 12566-3:2005+A1:2009, C.6.
SIST EN 12566-7 : 2013
Legenda:
kot trenja ≤ 63º
Slika 2: Preskus odprte enote v jami
6.3 Učinkovitost terciarnega čiščenja
6.3.1 Splošno
Za ugotavljanje učinkovitosti terciarnega čiščenja mora biti terciarna čistilna enota preskušena v skladu
z dodatkom A.
Če postopek terciarnega čiščenja vpliva na vstopne koncentracije BKP5 ali BKP7, KPK in neraztopljene
snovi, je treba ta vpliv navesti.
To se lahko zgodi pri uporabi enote za rekonstrukcijo ali v primeru recirkulacije.
6.3.2 Stopnja učinkovitosti terciarnega čiščenja
Učinkovitost terciarnega čiščenja mora biti izražena v obliki stopenj učinkovitosti terciarnega čiščenja z
oznako preskušene organske obremenitve in parametra za zmanjšanje.
Vsako stopnjo učinkovitosti terciarnega čiščenja je treba izračunati po enačbi:
izraženo v %;
kjer so:
RTT stopnja učinkovitosti terciarnega čiščenja za podani parameter (npr. BPK5 ali BPK7, celotni fosfor,
celotni dušik)
Pti vrednost podanega parametra na vtoku terciarne čistilne enote
Pt vrednost istega podanega parametra na iztoku terciarne čistilne enote
o
Navedena vrednost stopnje, izmerjene pri preskušeni dnevni obremenitvi podanega parametra, ne sme
presegati vrednosti stopnje (srednja vrednost stopenj učinkovitosti v okviru faz OSNOVNA), pridobljenih
s preskusom, opravljenim v skladu z dodatkom A.
Zabeležene vrednosti stopenj učinkovitosti terciarnega čiščenja neposredno ne pomenijo, da so
predpisane zahteve glede kakovosti odpadne vode v določeni državi članici izpolnjene. Opravi naj se
izračun s podatki iz poročila o preskusu, na podlagi katerega se določi končna kakovost odpadne vode,
ki jo je treba primerjati z zahtevami, veljavnimi v kraju predvidene uporabe. Teh stopenj ni mogoče
vedno pridobiti, ko enota deluje v praksi.
6.4 Vodotesnost
Terciarna čistilna enota mora biti vodotesna.
SIST EN 12566-7 : 2013
Pri enotah z rezervoarjem(-i) je treba rezervoar(-je) preskusiti v skladu z EN 12566-3:2005+A1:2009,
dodatek A, rezervoar(-ji) pa mora(-jo) izpolnjevati zahteve EN 12566-3:2005+A1:2009, 6.4.
Preskus vodotesnosti za enote, ki ne vključujejo rezervoarja, ni zahtevan.
Pri odprtih predizdelanih terciarnih čistilnih enotah je treba preskus vodotesnosti opraviti tako, da se
zatesnijo odprtine enote, nato pa se enota napolni do njene največje višine.
Pri preskusu vodotesnosti enot, izdelanih iz polidiciklopentadiena, je treba upoštevati navodila v EN
12566-3:2005+A1:2009, A.2.
6.5 Poraba energije
Kjer je to primerno, morajo biti navedeni podatki o porabi energije enote.
Poraba energije mora biti izmerjena med preskusom, opisanim v dodatku A, in izražena kot poraba pri
običajnih obratovalnih pogojih (faze nazivne obremenitve preskusa) v kWh/d.
Navedena vrednost porabe energije mora biti večja ali enaka vrednosti, izmerjeni med preskusom iz
A.2.4.4.
Poraba energije mora biti ocenjena z meritvami s točnostjo ±5 % izmerjene vrednosti.
6.6 Trajnost
6.6.1 Splošno
Predizdelane terciarne čistilne enote, vključno z vsemi notranjimi sestavnimi deli, morajo biti izdelane iz
materialov, ki z vidika trajnosti zagotavljajo njihovo ustreznost za uporabo v okolju gospodinjske
odpadne vode.
Materiali drugih sestavnih delov enote (tj. material filtra, črpalka itd.) morajo biti v skladu s
specifikacijami, ki jih proizvajalec posreduje dobavitelju materialov/sestavnih delov.
6.6.2 Beton, jeklo, PVC-U, PE, GRP
Za rezervoar iz betona, jekla, PVC-U, PE, GRP (tj. za osnovni material in premazi, kjer je to primerno)
mora biti material v skladu z EN 12566-3:2005+A1:2009, 6.5.2 do 6.5.7, če je to primerno.
6.6.3 PDCPD
Polidiciklopentadien (PDCPD), oblikovan z vbrizgavanjem, ki se uporablja za enoto, mora imeti
naslednje lastnosti:
–3
a) viskoznost sestavnih delov A in B po Brookfieldu pred vbrizgavanjem: > 210 x 10 Pa·s pri (30 ± 1) ºC
v skladu z EN ISO 2555;
b) gostota: več kot 1 000 kg/m pri (23 ± 2) ºC;
c) natezne lastnosti, določene v skladu z EN ISO 527 (vsi deli) (hitrost vlečenja = 50 mm/min):
1) E-modul: več kot 1 650 MPa,
2) obremenitev pri meji prožnosti: več kot 40 MPa,
3) raztezek pri meji prožnosti: več kot 3 %.
6.6.4 Hidroizolacijski trakovi
Lastnosti hidroizolacijskih trakov, uporabljenih za enoto, morajo biti v skladu s preglednico 1.
SIST EN 12566-7 : 2013
Preglednica 1: Lastnosti hidroizolacijskih trakov
Natezni preskus (kN/m)
Teža Prepustnost za tekočine
Material Debelina
pri raztezku 250 %
(g/m ) (glej EN 14150)
(glej EN 12311-2)
PEHD ≥ 1,5 mm > 1 400 ≥ 17 Skladno
PP ≥ 1 mm > 800 ≥ 5 Skladno
PVC ≥ 1 mm > 1 300 ≥ 7 Skladno
EPDM ≥ 1 mm > 1 400 ≥ 8 Skladno
6.7 Odziv na ogenj
6.7.1 Splošno
Kadar je uporaba predizdelane terciarne čistilne enote predmet nacionalno predpisanih zahtev o odzivu
na ogenj, je treba odziv na ogenj šteti za enega od sestavnih delov enote (tj. materialni vidik) in mora
biti naveden v obliki enega od naslednjih razredov v skladu z EN 13501-1:
a) razred A1 brez potrebe po preskušanju (CWT), kadar so izpolnjene zahteve, opredeljene v 6.7.2
ali kako drugače, ali
b) razred, določen skladno z rezultati preskušanja materiala(-ov), uporabljenega(-ih) v enoti, v skladu
s standardom(-i), navedenim(-i) v EN 13501-1, kot je določeno v 6.7.3.
OPOMBA 1: V večini primerov se šteje, da razred E zadostuje kot minimalna predpisana zahteva za odziv na ogenj pri
zakopanih (tj. podzemnih) enotah.
Če pa uporaba take enote ni predmet nacionalno predpisanih zahtev o odzivu na ogenj, se lahko navede
katerikoli razred, določen v skladu s točko a) ali b), ali razred F (glej opombo 2).
OPOMBA 2: Razred F je v skladu z EN 13501-1 enakovreden možnosti "Lastnost ni določena" (NPD).
6.7.2 Enote, klasificirane kot razred A1, brez potrebe po preskušanju
1)
Odziv enote na ogenj mora biti naveden kot razred A1 brez potrebe po preskušanju pod naslednjimi
pogoji:
a) nobeden od sestavnih materialov, iz katerih je izdelan rezervoar enote, ne vsebuje več kot 1 %
homogeno porazdeljenega organskega materiala glede na maso ali prostornino (kar je
zahtevnejše) in
PRIMER: Montažni armirani beton, ki se uporablja za predizdelano terciarno čistilno enoto, lahko na splošno vsebuje
organske materiale (npr. dodatke, aditive (če so uporabljeni), vendar je njihova vsebnost precej manjša od 1 %. Podobno
se jeklo, uporabljeno za enak namen, ne uporablja v finozrnati obliki. Zaradi nizke ravni gorljivosti in pod opisanimi pogoji
(glej opombo 1) se lahko v zvezi z odzivom na ogenj oba materiala brez preskušanja obravnavata kot materiala razreda
A1.
b) morebitni zunanji premaz, nanesen po površini rezervoarja, je izdelan iz anorganskega(-ih)
materiala(-ov), klasificiranega(-ih) kot material(-i) razreda A1 brez preskušanja, z debelino ≥ 1,0
mm ali maso na enoto površine ≥ 1,0 kg/m , ki je (so) ravno tako klasificiran(-i) kot material(-i)
razreda A1.
6.7.3 Enote, klasificirane v skladu z rezultati preskušanja
Z vidika odziva enote na ogenj pri morajo biti vsi sestavni materiali enote, vključno z materiali v njenem
površinskem premazu (če je uporabljen), klasificirani v skladu z EN 13501-1, pri čemer je treba navesti
samo najnižji razred teh materialov. Razred posameznega sestavnega materiala mora biti določen z
1)
Glej Odločbo Komisije 96/603/ES 1996-10-04 (glej OJEU L 267 1996-10-19), kot je bila dvakrat spremenjena z 2000/605/ES
2000-09-26 (glej OJEU L 258 2000-10-12) in z 2003/424/ES 2003-06-06 (glej OJEU L 144 2003-06-12).
SIST EN 12566-7 : 2013
rezultati preskusne(-ih) metode (metod), ustreznimi za ta razred, in kot to določajo standardi, navedeni
v EN 13501-1.
Sestavni material enote se šteje za material, ki lahko pomembno vpliva na odziv take enote na ogenj.
V skladu z definicijami, podanimi v EN 13501-1, lahko to velja v naslednjih primerih:
– homogena enota: njen material ali
– nehomogena enota: njen bistveni sestavni del, tj. material, ki tvori pomemben del te enote. Sloj s
površinsko gostoto ≥ 1,0 kg/m ali debelino ≥ 1,0 mm se šteje za bistveni sestavni del.
PRIMER: Na splošno se lahko to obravnava kot pomembno za enoto, pri kateri je rezervoar izdelan iz vsaj enega od naslednjih
sestavnih materialov: nemehčani polivinilklorid (PVC-U), polietilen (PE), s steklom ojačeni poliester (GRP-UP), polipropilen (PP)
in polidiciklopentadien (PDCPD); ali je vsebnik izdelan iz hidroizolacijskih trakov (PEHD, PP, PVC, OR EPDM), s površinskim
premazom ali brez njega.
Preskusne vzorce, ki se uporabijo za preskusne metode, primerne za to klasifikacijo, je treba pripraviti
v skladu z EN 13501-1 in ustreznimi standardi, na katere se ta sklicuje.
6.8 Nevarne snovi
Nacionalni predpisi o nevarnih snoveh lahko zahtevajo preverjanje in izjavo o sprostitvi (včasih tudi o
vsebini), kadar so gradbeni proizvodi, zajeti v tem standardu, na voljo na teh trgih.
Če ni evropskih usklajenih preskusnih metod, je treba pri preverjanju in izjavi o sprostitvi/vsebini
upoštevati nacionalne predpise v kraju uporabe.
OPOMBA: Informativna baza podatkov evropskih in nacionalnih predpisov o nevarnih snoveh je na voljo na spletni strani
EUROPA – Construction na naslovu http://ec.europa.eu/enterprise/construction/cpd-ds/.
7 Označevanje
7.1 Označevanje enote
Označba vsake predizdelane terciarne čistilne enote v skladu s tem standardom mora vključevati
naslednje informacije:
a) identifikacija proizvajalca in proizvoda,
b) številka tega standarda, tj. EN 12566-7,
c) vrsta materiala, uporabljenega za rezervoar, kjer je to primerno,
d) nazivna oznaka,
e) datum proizvodnje.
Kadar upravne določbe o označevanju zahtevajo informacije o nekaterih ali vseh elementih, navedenih
v tej točki, velja, da so zahteve te točke v zvezi s temi elementi izpolnjene.
7.2 Enoti priložene tehnične informacije
Vsaki predizdelani terciarni čistilni enoti morajo biti priložene naslednje tehnične informacije:
a) identifikacija proizvajalca in proizvoda,
b) številka tega standarda, tj. EN 12566-7,
c) informacije, potrebne pri opisu enote:
1) skupne dimenzije proizvoda,
2) rezervoar: material (vrsta) in premaz (vrsta in debelina), kjer je to primerno,
3) prostornina ali količina proizvodnje blata v nazivnih pogojih,
SIST EN 12566-7 : 2013
d) merila za določitev skupine proizvodov,
OPOMBA 1: Za pripravo teh meril je odgovoren proizvajalec; na ta način bo prikazana veljavnost izbire proizvodov za
začetno tipsko preskušanje.
e) informacije o lastnostih predizdelane terciarne čistilne enote:
1) nazivna oznaka terciarne čistilne enote (glej točko 5),
OPOMBA 2: Tem informacijam je lahko priložena enakovredna informacija v obliki celotne obremenitve (PE) na
predvidenem(-ih) kraju(-ih) uporabe enote.
2) stopnje učinkovitosti terciarnega čiščenja z oznako preskušene obremenitve, parametra za
zmanjšanje in temperaturnega območja zraka okolice med preskusom,
3) poraba energije enote v običajnih obratovalnih pogojih (faza OSNOVNA), če je to primerno,
4) vodotesnost,
5) obremenitvena zmogljivost, izražena kot:
i) največja dovoljena višina zasipa (m),
ii) možnost vgradnje enote na nivoju vodne gladine, izražena kot VLAŽNO ali SUHO,
OPOMBA 3: Metoda za določitev te lastnosti (tj. izračun ali preskušanje) je podana v skladu z materialom
rezervoarja.
6) trajnost,
f) kadar postopek terciarnega čiščenja vpliva na vrednosti BKP ali BKP , KPK in neraztopljene snovi,
5 7
je treba ta vpliv navesti,
g) postopki vgradnje, obratovanja in vzdrževanja,
h) datum proizvodnje,
i) številke poročil o preskusih.
Predvidene so lahko tudi druge tehnične informacije.
Kadar upravne določbe o označevanju zahtevajo informacije o nekaterih ali vseh elementih, navedenih
v tej točki, velja, da so zahteve te točke v zvezi s temi elementi izpolnjene.
8 Vrednotenje skladnosti
8.1 Splošno
Skladnost predizdelane terciarne čistilne enote z zahtevami tega standarda in z navedenimi vrednostmi
za navedene lastnosti (npr. vrednosti, razredi) je treba prikazati:
– z začetnim tipskim preskušanjem (ITT) in tipskim preskušanjem (TT), kjer se uporablja (glej 8.2);
– s kontrolo proizvodnje v obratu, ki jo opravi proizvajalec, vključno z oceno enote (glej 8.3).
Proizvajalec mora vedno imeti nadzor in mora imeti potrebna sredstva, da prevzame odgovornost za
enoto.
8.2 Začetno tipsko preskušanje – tipsko preskušanje
8.2.1 Splošno
Za prikaz skladnosti predizdelane terciarne čistilne enote z zahtevami tega evropskega standarda je
treba opraviti začetno tipsko preskušanje (ITT) in tipsko preskušanje (TT), kjer se uporablja.
Vse bist
...