EN 124-5:2015
(Main)Gully tops and manhole tops for vehicular and pedestrian areas - Part 5: Gully tops and manhole tops made of composite materials
Gully tops and manhole tops for vehicular and pedestrian areas - Part 5: Gully tops and manhole tops made of composite materials
This European Standard is applicable to manhole tops and gully tops made of composite materials C1, C2 and C3 by using suitably controlled automatic processes that produce a single structure and that do not contain multiple pieces bonded together, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic.
It is applicable to manhole tops and gully tops for use in:
- areas which can only be used by pedestrians and pedal cyclists (class A 15),
- pedestrian areas and comparable areas, car parks or car parking decks (class B 125),
- the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (class C 250),
and in addition to manhole tops for use in
- carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (class D 400).
This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/gratings made from composite materials with frames according to EN 124-2, EN 124-3, EN 124-4 and EN 124-6.
This document is not applicable to:
- manhole tops and gully tops manufactured by means of hand lay-up method,
- gratings/covers as part of prefabricated drainage channels according to EN 1433,
- floor and roof gullies in buildings which are specified in EN 1253 (all parts), and
- surface boxes.
Aufsätze und Abdeckungen für Verkehrsflächen - Teil 5: Aufsätze und Abdeckungen aus Verbundwerkstoffen
Diese Europäische Norm gilt für Abdeckungen und Aufsätze aus Verbundwerkstoffen vom Typ C1, C2 und C3, mit einer lichte Weite bis einschließlich 1 000 mm zum Abdecken von Abläufen, Einsteig- und Kontrollschächten in Flächen, die für Fußgänger- und/oder Fahrzeugverkehr bestimmt sind. Sie werden in geeigneten überwachten automatischen Prozessen als ein Teil gefertigt und bestehen nicht aus mehreren, miteinander verbundenen Einzelteilen.
Sie gilt für Abdeckungen und Aufsätze zum Einbau in
- Flächen, die ausschließlich von Fußgängern und Radfahrern benutzt werden können (mindestens Klasse A 15),
- Fußgängerzonen und vergleichbare Flächen, PKW Parkflächen oder PKW-Parkdecks (mindestens Klasse B 125),
- Bereiche im Bordrinnenbereich von Straßen, der, gemessen ab Bordsteinkante, höchstens 0,5 m in die Fahrbahn und höchstens 0,2 m in die Fußgängerzone hineinreicht (mindestens Klasse C 250),
und zusätzlich gilt sie für Abdeckungen zum Einbau in
- Fahrbahnen von Straßen (auch Fußgängerstraßen), Seitenstreifen von Straßen und Parkflächen, die für alle Arten von Straßenfahrzeugen zugelassen sind (mindestens Klasse D 400),
Diese Europäische Norm ist nur in Verbindung mit FprEN 124-1 anwendbar und enthält Anleitungen für Kombinationen von Deckeln/Rosten aus Verbundwerkstoffen mit Rahmen nach FprEN 124-2, FprEN 124-3, FprEN 124-4 und FprEN 124-6.
Dieses Dokument gilt nicht für
- handgefertigte Abdeckungen und Aufsätze,
- Roste/Deckel als Teil vorgefertigter Entwässerungsrinnen nach EN 1433,
- Dach- und Bodenabläufe in Gebäuden, wie in EN 1253 (alle Teile) festgelegt,
- Straßenkappen.
Dispositifs de couronnement et de fermeture pour les zones de circulation utilisées par les piétons et les véhicules - Partie 5: Dispositifs de couronnement et de fermeture en matériaux composites
La présente Norme européenne est applicable aux dispositifs de fermeture et de couronnement fabriqués en matériaux composites C1, C2 et C3 à l'aide de procédés automatiques convenablement contrôlés qui sont moulés comme une structure unique et qui ne contiennent pas plusieurs pièces collées ensemble, avec une cote de passage inférieure ou égale à 1 000 mm pour la fermeture des ouvertures des avaloirs, des regards de visite et des boîtes d'inspection ou de branchement installés dans des zones soumises à la circulation des piétons et/ou de véhicules.
Elle est applicable aux dispositifs de fermeture et de couronnement à utiliser dans
- les zones susceptibles d’être utilisées exclusivement par des piétons et des cyclistes (classe A 15),
- les zones piétonnes et zones comparables, aires de stationnement ou parkings à étages pour voitures (classe B 125),
- la zone des caniveaux ou bordures longeant les voies de circulation et les trottoirs qui, mesurée à partir de la bordure, s'étend au maximum à 0,5 m côté voie de circulation, et au maximum à 0,2 m côté zone piétonne (classe C 250),
et en plus des dispositifs de fermeture à utiliser dans les
- voies de circulation des routes (y compris les rues piétonnes), les accotements stabilisés et les aires de stationnement pour tous types de véhicules routiers (classe D 400).
La présente Norme européenne n'est pas applicable individuellement, mais uniquement en association avec le FprEN 124 1 et fournit également des lignes directrices pour les combinaisons de tampons/grilles fabriquées en matériaux composites avec des cadres conformément aux FprEN 124 2, FprEN 124 3, FprEN 124 4 et FprEN 124 6.
Le présent document ne s’applique pas
- aux dispositifs de fermeture et de couronnement fabriqués par des méthodes de moulage à la main,
- aux grilles/tampons faisant partie des caniveaux hydrauliques préfabriqués conformes à l'EN 1433,
- aux avaloirs de sol et de toiture dans les bâtiments qui sont spécifiés dans l'EN 1253 (toutes les parties), ni
- aux bouches à clé.
Pokrovi za odtoke in jaške na voznih površinah in površinah za pešce - 5. del: Pokrovi za odtoke in jaške iz kompozitnih materialov
Ta standard se uporablja za pokrove za odtoke in jaške s svetlo odprtino do vključno 1000 mm, ki so nameščeni na območjih s površino za pešce in/ali vozno površino. Ta standard se uporablja za pokrove za jaške in odtoke ter rešetke – razredov A15 do C250, iz kompozita tipa A, ter – razredov A15 in B125 iz kompozita tipa B. OPOMBA 1: Za uporabe pri stalnih temperaturah nad 120 °C so lahko potrebne dodatne zahteve. Pokrovi za jaške in odtoke v skladu s tem standardom so izdelani iz kompozitnih materialov z uporabo ustrezno nadzorovanih samodejnih procesov, ki so oblikovani kot enotna struktura ter ne zajemajo več medsebojno povezanih kosov. Izdelki, izdelani z metodami ročnega laminiranja, so zunaj področja uporabe tega standarda. 5. del se ne uporablja samostojno, ampak samo v kombinaciji s standardom EN 124-1. Ta standard se ne uporablja za polnila, nameščena na kraju, kot so beton, tlakovci itd. Ne uporablja se za rešetke v okviru predizdelane padavinske kanalizacije v skladu s standardom EN 1433 ali za talne odtoke in strešne žlebove v stavbah, ki so navedeni v standardu EN 1253-1, ter za površinske škatle.
General Information
- Status
- Published
- Publication Date
- 09-Jun-2015
- Technical Committee
- CEN/TC 165 - Waste water engineering
- Drafting Committee
- CEN/TC 165/WG 4 - Gullies and tops a.s.o.
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 11-Jun-2021
- Completion Date
- 14-Apr-2025
- Directive
- 89/106/EEC - Construction products
Relations
- Effective Date
- 08-Jun-2022
Overview
EN 124-5:2015 is the CEN European Standard that specifies requirements and test methods for gully tops and manhole tops made of composite materials. It applies to single-piece products manufactured by controlled automatic processes (not hand lay‑up), with a clear opening up to and including 1 000 mm, intended for use in areas subject to pedestrian and/or vehicular traffic. The standard must be used in combination with EN 124-1 and gives guidance for combinations of composite covers/gratings with frames complying with EN 124-2, EN 124-3, EN 124-4 and EN 124-6.
Key Topics
- Scope & materials: Covers composite material types C1, C2 and C3, manufacturing constraints (single-structure parts), and explicit exclusions (hand lay‑up, drainage channels per EN 1433, building gullies per EN 1253, and surface boxes).
- Load classes: Products are intended for defined traffic classes: A 15, B 125, C 250, D 400, with specific application zones (pedestrian areas, car parks, kerbside channels, carriageways).
- Material properties: Requirements include hardness, water absorption, resistance to vehicle fuels, surface resistivity and weathering resistance.
- Mechanical performance: Mandatory tests and criteria for deflection under load, resistance to fatigue, creep resistance, impact resistance and effect of heating.
- Reaction to fire & durability: Guidance on reaction-to-fire classification (referencing EN 13501-1) and long‑term durability considerations for composite materials.
- Conformity & factory control: Assessment and Verification of Constancy of Performance (AVCP), type testing, factory production control (FPC), Declaration of Performance (DoP) and CE marking requirements (Annex ZA).
Applications
EN 124-5:2015 is practical for:
- Manufacturers designing and producing composite gully tops and manhole tops to meet European regulatory and market requirements.
- MEP and civil engineers specifying covers for pedestrian zones, car parks, kerbside channels and road carriageways (load classes A 15–D 400).
- Procurement teams and asset owners requiring compliant products with verified performance, DoP and CE marking.
- Test laboratories and conformity assessment bodies performing type tests, FPC audits and issuing reports per AVCP.
Related Standards
- EN 124-1:2015 (general principles, test methods)
- EN 124-2 / EN 124-3 / EN 124-4 / EN 124-6 (frames and other materials)
- EN 59 (Barcol hardness)
- EN 13501-1, EN 13823 (reaction to fire)
- EN ISO 62, EN ISO 175 (material tests)
- Exclusions referenced: EN 1433 (drainage channels) and EN 1253 (floor/roof gullies)
Use EN 124-5:2015 when specifying or producing composite manhole and gully covers to ensure compliance with European performance, safety and durability expectations for pedestrian and vehicular areas.
Frequently Asked Questions
EN 124-5:2015 is a standard published by the European Committee for Standardization (CEN). Its full title is "Gully tops and manhole tops for vehicular and pedestrian areas - Part 5: Gully tops and manhole tops made of composite materials". This standard covers: This European Standard is applicable to manhole tops and gully tops made of composite materials C1, C2 and C3 by using suitably controlled automatic processes that produce a single structure and that do not contain multiple pieces bonded together, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in: - areas which can only be used by pedestrians and pedal cyclists (class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (class C 250), and in addition to manhole tops for use in - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (class D 400). This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/gratings made from composite materials with frames according to EN 124-2, EN 124-3, EN 124-4 and EN 124-6. This document is not applicable to: - manhole tops and gully tops manufactured by means of hand lay-up method, - gratings/covers as part of prefabricated drainage channels according to EN 1433, - floor and roof gullies in buildings which are specified in EN 1253 (all parts), and - surface boxes.
This European Standard is applicable to manhole tops and gully tops made of composite materials C1, C2 and C3 by using suitably controlled automatic processes that produce a single structure and that do not contain multiple pieces bonded together, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in: - areas which can only be used by pedestrians and pedal cyclists (class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (class C 250), and in addition to manhole tops for use in - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (class D 400). This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/gratings made from composite materials with frames according to EN 124-2, EN 124-3, EN 124-4 and EN 124-6. This document is not applicable to: - manhole tops and gully tops manufactured by means of hand lay-up method, - gratings/covers as part of prefabricated drainage channels according to EN 1433, - floor and roof gullies in buildings which are specified in EN 1253 (all parts), and - surface boxes.
EN 124-5:2015 is classified under the following ICS (International Classification for Standards) categories: 93.080.30 - Road equipment and installations. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 124-5:2015 has the following relationships with other standards: It is inter standard links to EN 124:1994. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 124-5:2015 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 88/379/EEC, 89/106/EEC; Standardization Mandates: M/118 REV1. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 124-5:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Pokrovi za odtoke in jaške na voznih površinah in površinah za pešce - 5. del: Pokrovi za odtoke in jaške iz kompozitnih materialovAufsätze und Abdeckungen für Verkehrsflächen - Teil 5: Aufsätze und Abdeckungen aus VerbundwerkstoffenDispositifs de couronnement et de fermeture pour les zones de circulation utilisées par les piétons et les véhicules - Partie 5: Dispositifs de couronnement et de fermeture en matériaux compositesGully tops and manhole tops for vehicular and pedestrian areas - Part 5: Gully tops and manhole tops made of composite materials93.080.30Cestna oprema in pomožne napraveRoad equipment and installationsICS:Ta slovenski standard je istoveten z:EN 124-5:2015SIST EN 124-5:2015en,fr,de01-september-2015SIST EN 124-5:2015SLOVENSKI
STANDARDSIST EN 124:19961DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 124-5
June 2015 ICS 93.080.30 Supersedes EN 124:1994English Version
Gully tops and manhole tops for vehicular and pedestrian areas -Part 5: Gully tops and manhole tops made of composite materials
Dispositifs de couronnement et de fermeture pour les zones de circulation utilisées par les piétons et les véhicules - Partie 5: Dispositifs de couronnement et de fermeture en matériaux composites
Aufsätze und Abdeckungen für Verkehrsflächen - Teil 5: Aufsätze und Abdeckungen aus Verbundwerkstoffen This European Standard was approved by CEN on 12 March 2015.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 124-5:2015 ESIST EN 124-5:2015
Test of deflection under load . 28 A.1 Test Samples . 28 A.2 Deflection test load, FD . 28 A.3 Apparatus . 28 A.3.1 Testing machine . 28 A.3.2 Test blocks . 28 A.3.3 Deflection measurement device(s) . 28 A.4 Procedure . 28 A.4.1 Procedure for testing rectangular and circular covers/gratings . 28 A.4.2 Procedure for testing multiple and triangular covers/gratings . 29 A.5 Observations and reporting . 29 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 30 ZA.1 Scope and relevant characteristics . 30 ZA.2 Procedures for AVCP of gully tops and manhole tops made of composite materials . 32 ZA.2.1 Systems of AVCP . 32 ZA.2.2 Declaration of performance (DoP) . 33 ZA.2.2.1 General . 33 ZA.2.2.2 Content. 34 ZA.2.2.3 Example of DoP . 34 ZA.3 CE marking and labelling. 36 Bibliography . 38
according to EN 124-1:2015, Clause Relevant for class A 15 B 125 C 250 D 400 a Related to the design Vents in covers 6.1 8.4.1 x x x x Clear opening of manhole tops for man entry 6.2 8.4.2 x x x x Depth of insertion 6.3 8.4.3 – – – x Clearance 6.4 8.4.4 x x x x Compatibility of seatings 6.5 8.4.5 – – – x Handling of covers and gratings 6.7 8.4.7 x x x x SIST EN 124-5:2015
according to EN 124-1:2015, Clause Relevant for class A 15 B 125 C 250 D 400 a Slot dimensions of gratings 6.8 8.4.8 x x x x Dirt pans and dirt buckets 6.9 8.4.9 x x x x Positioning of covers and gratings 6.10 8.4.10 x x x x Flatness of manhole covers and gratings 6.11 8.4.11 – – – x Concaveness of gratings 6.12 8.4.12 x x x x Surface conditions 6.13 8.4.13 x x x x Manhole tops with sealing feature 6.14 Visual inspection of presence of anchors x x x x Frame bearing area 6.15 8.4.14 x x x x Frame depth 6.16 8.4.15 – – – x Opening angle of hinged covers/gratings 6.17 8.4.16 x x x x Appearance 7.1 Visual inspection x x x x Related to the performance Load bearing capacity 7.2 8.3 x x x x Permanent set 7.3 8.2 x x x x Securing of the cover/grating within the frame 6.6 a) or c) 8.4.6 x x x x Skid resistance 7.4 8.4.13 x x x x Child safety 7.5 8.5 x x x x x To be applied. a For manhole tops only. 5.2 Material specific characteristics for gully tops and manhole tops made of composite materials 5.2.1 Reinforcement The dimensions, position, spacing and jointing of the reinforcement and foam, if applicable, shall be in accordance with the design. 5.2.2 Deflection under load When tested the complete composite manhole top and gully top in accordance with 6.2 and when subject to FD = 1/3 FT, the maximum deflection under load shall be ≤ CO/360 for covers to be filled with brittle materials other than concrete. For covers to be filled with concrete, the maximum deflection under load shall be ≤ CO/250. For all other covers according to this standard, the maximum deflection under load shall be declared as mm per mm of clear opening (mm/CO). The load deflection curve shall be smooth and progressive without sudden deviations up to the test load. SIST EN 124-5:2015
FF kN Load application rate
kN/s B 125 10 000 43 7 ± 2 C 250 100 000 92 42 ± 14 D 400 a 100 000 500 000 136 120 70 ± 20 60 ± 20 a Test conditions for class D 400 can be used either or. They both refer to the same stress level. The conditions are selected by the manufacturer. 6.4 Creep resistance A test equipment according to EN 124-1:2015, Annex A, shall be used. A load shall be applied to a manhole top that has not previously been subjected to any prior form of load test, to the permanent set load specified in EN 124-1:2015, 8.2, for a period of ()1060+ minutes. A recover for ()5,005+ minutes after complete removal of the load shall be allowed. The measurement shall be taken in accordance with EN 124-1:2015, Annex A. This test is not required to class A 15. 6.5 Impact resistance Depending on the temperature in the place of use, impact resistance shall be tested in accordance with Table 5 to ensure that the manhole tops and gully tops do not suffer from low temperature embrittlement. SIST EN 124-5:2015
— class B 125 — class C 250 — class D 400 Radius of striker; Rs 50 mm a Cold climate conditions: Products tested at –20 °C shall be marked with a snow flake symbol. Set up the apparatus and support to ensure minimum time elapses from removal of test specimen from chill unit to testing. The longitudinal axis of the impact nose shall be aligned at right angles to the surface of installation of the manhole top or gully top. Condition the test specimen at test temperature for 4 h. Remove and place on support, impact test from a height of 2,0 m from the impact point within 30 s. Impact test shall be carried out at 7 equally spaced points, at least 4 to be around the periphery. The impact nose shall be directed at those areas that would normally be “exposed” when installed. Return the test specimen to the chill unit for between 10 min and 15 min to recondition if the completion of the 7 impacts exceeds 120 s. SIST EN 124-5:2015
...
Die Norm EN 124-5:2015 befasst sich mit den Gully- und Schachtabdeckungen aus Verbundwerkstoffen, die in Bereichen für Fußgänger und Fahrzeuge eingesetzt werden. Der Umfang dieser europäischen Norm ist klar definiert und gilt insbesondere für die Abdeckungen, die unter speziellen, kontrollierten automatisierten Prozessen hergestellt werden. Diese Prozesse tragen dazu bei, dass die Produkte aus einem einzigen Stück bestehen und nicht aus mehreren miteinander verklebten Teilen. Dies sorgt für eine verbesserte Festigkeit und Langlebigkeit der Abdeckungen. Ein wesentliches Merkmal dieser Norm ist die umfassende Anwendbarkeit auf unterschiedliche Klassen, die je nach Nutzung der Fläche variieren. So können die Abdeckungen in Geh- und Radfahrerbereichen (Klasse A 15), in Parkhäusern oder ähnlichen Einrichtungen (Klasse B 125), und in Straßenbereichen (Klasse C 250) eingesetzt werden, wobei hier die Dimensionen klar spezifiziert sind. Besonders hervorzuheben ist die Eignung für Fahrbahnen, einschließlich Fußgängerzonen und Parkplätze für alle Arten von Straßenfahrzeugen (Klasse D 400), was die universelle Anwendbarkeit der Norm unterstreicht. Die Norm EN 124-5:2015 ermöglicht zudem die Kombination von Gully- und Schachtabdeckungen mit Rahmen gemäß den Normen EN 124-1, EN 124-2, EN 124-3, EN 124-4 und EN 124-6. Dies sorgt für eine integrierte Herangehensweise beim Bau und bei der Installation von Entwässerungssystemen. Darüber hinaus sind klare Ausschlüsse definiert, was zur Klarheit und zur Vermeidung von Missverständnissen beiträgt. Abdeckungen und Gullys, die mittels Handschichtverfahren hergestellt werden, sowie Vorfabrikationsteile gemäß EN 1433 fallen nicht unter die Regelungen dieser Norm. Dies ist besonders wichtig für Planer und Ingenieure, die sicherstellen möchten, dass sie die richtigen Produkte für ihre spezifischen Anforderungen wählen. Insgesamt bietet die EN 124-5:2015 eine klare, strukturierte und umfassende Richtlinie für die Verwendung von Gully- und Schachtabdeckungen aus Verbundwerkstoffen, die für die Sicherheit und den Komfort im Straßenverkehr von großer Bedeutung ist. Die Norm ist daher relevant und zeitgemäß, um die Anforderungen an moderne Infrastruktur und Entwässerungssysteme zu erfüllen.
The standard EN 124-5:2015 outlines the requirements for gully tops and manhole tops made of composite materials in vehicular and pedestrian areas. This document is critical for ensuring consistency and safety in urban infrastructure by specifying guidelines for products that cater to a variety of usage scenarios, including areas designated for pedestrians and cyclists (class A 15), pedestrian-related car parks (class B 125), and parts of the carriageway (class C 250 and D 400). One of the significant strengths of this standard is its focus on composite materials, which are increasingly preferred for their durability and lightweight properties. The specification that the tops must be produced from a single structure, rather than bonded pieces, ensures structural integrity and reliability in high-traffic environments. This detail speaks to the relevance of the standard, particularly in today’s engineering landscape where composite materials are becoming standard in construction due to their resilience and lower maintenance needs. Moreover, the standard’s comprehensive scope addresses various classes of loadings, ensuring that the products can effectively withstand the demands of their respective environments. This classification allows for the appropriate selection of manhole and gully covers that are specifically designed for their intended use, promoting safety and reducing the risk of structural failure. Furthermore, by outlining the limitations of applicability, such as excluding products manufactured through hand lay-up methods, the standard clarifies what constitutes compliance, preventing ambiguity in material manufacturing and usage. The emphasis on using EN 124-1 in conjunction with this standard further solidifies its relevance, as it provides a cohesive framework for assessing the performance of covers and gratings made from composite materials. In summary, EN 124-5:2015 effectively fills a critical gap in the regulatory landscape by prescribing requirements for manhole and gully tops made of composite materials, thereby enhancing safety, ensuring compatibility, and promoting the use of advanced materials in public infrastructure.
SIST EN 124-5:2015 표준 문서는 복합 재료로 제작된 맨홀 덮개 및 배수구 덮개에 대한 매우 중요한 지침을 제공합니다. 이 표준의 범위는 보행자와 차량 통행이 있는 지역에서 사용되는 복합 재료로 만들어진 맨홀 및 배수구 덮개의 설계 및 생산에 중점을 둡니다. 표준은 C1, C2, C3 클래스로 분류된 단일 구조물을 다루며, 최대 1,000 mm의 개구부를 허용하여 다양한 사용 환경에 적합하도록 하고 있습니다. 이 표준의 강점은 다양한 사용 조건에 대한 명확한 기준을 제공한다는 점입니다. 특히, 보행자와 자전거 사용자만 이용하는 A15 클래스, 주차장이나 보행자 지역의 B125 클래스, 도로의 커브 사이드 채널인 C250 클래스, 그리고 모든 유형의 도로 차량을 위한 D400 클래스에 대한 명확한 정의를 제공합니다. 이러한 다양한 범주는 복합 재료 덮개가 실질적으로 사용될 수 있는 환경을 보장하며, 설치 및 유지 관리 시 배수구 및 맨홀 덮개에 대한 신뢰성을 높입니다. SIST EN 124-5:2015는 EN 124-1와 함께 사용되어야 하며, 이를 통해 복합 재료로 된 덮개/그레이트와 EN 124-2, EN 124-3, EN 124-4, EN 124-6에 따른 프레임의 조합에 대한 명확한 가이드를 제공합니다. 이러한 통합적 접근은 모든 관련 표준 간의 일관성을 보장하며, 실제 적용 시 조절 및 조화된 방법으로 다양한 구성품이 상호작용할 수 있도록 합니다. 이 표준은 특정 제작 방법을 배제하여 불필요한 혼란을 줄이고, 더욱 정밀하고 안전한 제품 개발을 촉진합니다. 예를 들어, 손으로 수작업으로 제작된 맨홀 덮개 및 배수구 덮개, EN 1433에 따른 프리패브 드레인 채널의 일부로서의 그레이트/덮개, 그리고 EN 1253에 명시된 건물 내 바닥 및 지붕 배수구에 대해서는 적용되지 않습니다. 이러한 명확한 구분은 사용자가 올바른 재료 및 설계지침을 선택할 수 있도록 돕습니다. 결론적으로, SIST EN 124-5:2015는 보행자와 차량 통행이 있는 지역에서 복합 재료로 제작된 덮개와 관련하여 명확하고 신뢰할 수 있는 표준을 제공하며, 해당 분야의 안전성과 성능을 한층 강화합니다.
La norme EN 124-5:2015 spécifie les exigences relatives aux couvercles de regards et de puisards pour les zones piétonnes et de circulation, en se concentrant sur les matériaux composites, notamment les classes C1, C2 et C3. Son champ d'application est clairement défini, englobant une large gamme d'utilisations allant des zones uniquement accessibles aux piétons et cyclistes (classe A 15) jusqu'aux chaussées principales pour tous types de véhicules (classe D 400). Cette diversité d’applications témoigne de la pertinence de la norme dans la conception et l’implémentation des infrastructures urbaines modernes. Parmi ses points forts, cette norme garantit une production contrôlée par des processus automatisés pour créer des structures monoblocs, réduisant ainsi les risques de défaillance associés aux assemblages de pièces multiples. Cela souligne l’importance de la durabilité et de la sécurité dans les zones soumises à un trafic important. En outre, la norme établit des dimensions précises pour les ouvertures allant jusqu'à 1 000 mm, ce qui facilite l’adaptation de ces couvercles aux différents types de puisards et de regards dans des environnements variés. La norme EN 124-5:2015 est également pertinente en interagissant avec d'autres normes européennes telles que EN 124-1, EN 124-2 et EN 124-6, offrant des lignes directrices pour l'intégration de couvercles en matériaux composites avec des cadres correspondant à des standards établis de qualité et de performance. Cela en fait un outil essentiel pour les ingénieurs et concepteurs impliqués dans le développement des infrastructures urbaines. Il est essentiel de noter que la norme exclut certains types de produits tels que ceux fabriqués par la méthode du laminage à la main ou les grilles intégrées dans des systèmes de drainage préfabriqués. Cette délimitation permet d’affiner les applications de la norme et d'assurer que les utilisateurs se concentrent uniquement sur les produits conformes aux exigences spécifiées pour la sécurité et la durabilité. En conclusion, la norme EN 124-5:2015 représente un cadre solide pour la fabrication et l'utilisation de couvercles de regards et de puisards en matériaux composites, garantissant sécurité, fiabilité et conformité aux exigences d'infrastructures variées.
SIST EN 124-5:2015は、歩行者および車両用エリア向けの複合材料で作られたマンホールと排水溝の蓋に関する欧州標準であり、特にその適用範囲と重要性において優れたものです。この標準は、適切に制御された自動プロセスを用いて製造された単一構造の複合材料の蓋を対象としており、これは複数の部品を接合していないことを明確に定義しています。蓋の開口部は最大1,000mmまで対応しており、歩道や車両交通があるエリアに設置するための指針となります。 この標準の強みは、特定の使用条件に応じた分級があり、歩行者や自転車専用道路(クラスA 15)、駐車場(クラスB 125)、および車道の縁から0.5m以内の場所(クラスC 250)や、すべての種類の車両用の車道(クラスD 400)でも使用できることです。これにより、さまざまな交通条件下での安全性と耐久性が確保されています。 加えて、この標準は、EN 124-1や他の関連標準(EN 124-2、EN 124-3、EN 124-4、EN 124-6)と組み合わせて適用される必要があることを強調しており、複合材料製の蓋とフレームの組み合わせに関するガイダンスを提供しています。このことは、設計者や施工業者にとって非常に重要な情報であり、標準に基づいた製品選定の際の混乱を避けることができます。 重要な点として、手作業で製造された蓋、EN 1433に基づくプレファブリケート排水チャネルの一部としてのグレーティング、EN 1253に指定された建物内の床および屋根用排水溝、ならびにサーフェスボックスには適用されないことが明記されています。これにより、使用対象が明確になり、標準の適切な利用が促進されます。 総じて、SIST EN 124-5:2015は、さまざまなエリアでの安全かつ効果的な運用を保証するための明確な基準を提供しており、特に複合材料の利用において確かな指針を示しています。このように、この標準は業界における重要なリソースとなっており、その実用性と関連性は高く評価されています。










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...