EN ISO 11092:2014
(Main)Textiles - Physiological effects - Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test) (ISO 11092:2014)
- Abstract
ISO 11092:2014 specifies methods for the measurement of the thermal resistance and water-vapour resistance, under steady-state conditions, of e.g. fabrics, films, coatings, foams and leather, including multilayer assemblies, for use in clothing, quilts, sleeping bags, upholstery and similar textile or textile-like products.
The application of this measurement technique is restricted to a maximum thermal resistance and water-vapour resistance which depend on the dimensions and construction of the apparatus used (e.g. 2 m2·K/W and 700 m2·Pa/W respectively, for the minimum specifications of the equipment referred to in ISO 11092:2014).
- Status
- Withdrawn
- Publication Date
- 02-Sep-2014
- Withdrawal Date
- 17-Nov-2026
- Technical Committee
- CEN/TC 248 - Textiles and textile products
- Drafting Committee
- CEN/TC 248 - Textiles and textile products
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 03-Jun-2026
Overview
EN ISO 11092:2014 specifies a standardized laboratory method - the sweating guarded‑hotplate test (skin model) - for measuring the thermal and water‑vapour transport properties of textile and textile‑like materials under steady‑state conditions. The standard covers measurement of thermal resistance (Rct) and water‑vapour resistance (Ret) for single materials and multilayer assemblies such as fabrics, films, coatings, foams and leather used in clothing, quilts, sleeping bags, upholstery and similar products. The method is intended for textile testing laboratories, R&D and product development teams concerned with clothing comfort and moisture management.
Key topics and technical requirements
- Test principle: A sweating guarded‑hotplate simulates skin; heat and evaporative fluxes through a specimen are measured under steady‑state conditions.
- Measured quantities:
- Thermal resistance (Rct) - temperature difference across the material divided by heat flux (m²·K/W).
- Water‑vapour resistance (Ret) - vapour pressure difference across the material divided by evaporative heat flux (m²·Pa/W).
- Water‑vapour permeability index (imt) - dimensionless ratio combining Rct and Ret to indicate moisture permeability relative to air.
- Water‑vapour permeability (Wd) - expressed in g·m⁻²·h⁻¹·Pa⁻¹ and derived from Ret and latent heat of vaporization.
- Apparatus and limits: Minimum equipment specifications determine maximum measurable values (example: instrument limits cited in the standard are around 2 m²·K/W for Rct and 700 m²·Pa/W for Ret for the minimum apparatus configuration).
- Test procedure elements:
- Determination of apparatus constants and correction terms.
- Specimen preparation and assembly (separate procedures for materials ≤5 mm and >5 mm thickness).
- Measurement steps for Rct and Ret under controlled temperature, humidity and air‑speed.
- Quality and reporting: The standard includes guidance on repeatability, reproducibility, required test report content and normative annexes (mounting procedures, correction-term determination, specimen assembly guidance).
Applications and users
- Practical uses:
- Objective comparison of thermal insulation and moisture resistance of garments, sleeping bags, upholstery and protective clothing.
- Product development to optimize wearer comfort, layering systems and moisture management.
- Performance verification for textile suppliers and OEMs, and for labeling or specification compliance.
- Primary users:
- Textile testing laboratories and certification bodies
- Apparel and outdoor product designers and R&D engineers
- Manufacturers of technical textiles, PPE and bedding products
Related standards
- EN ISO 11092:2014 supersedes earlier EN 31092/ISO 11092 editions and was prepared by ISO/TC 38 (Textiles). It is typically used alongside other textile comfort and moisture‑transport test methods when assessing overall clothing performance.
Relations
- Effective Date
- 10-Sep-2014
- Effective Date
- 22-Jan-2014
- Effective Date
- 18-Jan-2023
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Referred By
EN 4863:2023 - Aerospace series - Rotorcraft immersion suits - Requirements, testing and marking - Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.
Hohenstein Institut
Textile testing and certification.

Bureau Veritas Bangladesh
Bureau Veritas certification services in Bangladesh.
Sponsored listings
Frequently Asked Questions
EN ISO 11092:2014 is a standard published by the European Committee for Standardization (CEN). Its full title is "Textiles - Physiological effects - Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test) (ISO 11092:2014)". This standard covers: ISO 11092:2014 specifies methods for the measurement of the thermal resistance and water-vapour resistance, under steady-state conditions, of e.g. fabrics, films, coatings, foams and leather, including multilayer assemblies, for use in clothing, quilts, sleeping bags, upholstery and similar textile or textile-like products. The application of this measurement technique is restricted to a maximum thermal resistance and water-vapour resistance which depend on the dimensions and construction of the apparatus used (e.g. 2 m2·K/W and 700 m2·Pa/W respectively, for the minimum specifications of the equipment referred to in ISO 11092:2014).
ISO 11092:2014 specifies methods for the measurement of the thermal resistance and water-vapour resistance, under steady-state conditions, of e.g. fabrics, films, coatings, foams and leather, including multilayer assemblies, for use in clothing, quilts, sleeping bags, upholstery and similar textile or textile-like products. The application of this measurement technique is restricted to a maximum thermal resistance and water-vapour resistance which depend on the dimensions and construction of the apparatus used (e.g. 2 m2·K/W and 700 m2·Pa/W respectively, for the minimum specifications of the equipment referred to in ISO 11092:2014).
EN ISO 11092:2014 is classified under the following ICS (International Classification for Standards) categories: 59.080.01 - Textiles in general; 59.080.30 - Textile fabrics; 61.020 - Clothes. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 11092:2014 has the following relationships with other standards: It is inter standard links to EN 31092:1993/A1:2012, EN 31092:1993, EN ISO 11092:2026, EN 50286:2025, EN IEC 63203-201-3:2021, EN 343:2003+A1:2007, EN 342:2017, EN 15614:2007, EN 17528:2022, EN 4863:2023, CEN/TR 16422:2012, EN 16689:2017, EN 471:2003+A1:2007, EN 16781:2018, CEN/TS 14237:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 11092:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2014
1DGRPHãþD
SIST EN 31092:1999
7HNVWLOLMH8JRWDYOMDQMHIL]LRORãNLKODVWQRVWL0HUMHQMHWRSORWQHLQSDUQHXSRUQRVWL
SULXVWDOMHQLKSRJRMLKSUHVNXV]YURþRSORãþR]DãþLWHQRSUHGL]JXER,62
Textiles - Physiological effects - Measurement of thermal and water-vapour resistance
under steady-state conditions (sweating guarded-hotplate test) (ISO 11092:2014)
Textilien - Physiologische Wirkungen - Messung des Wärme- und
Wasserdampfdurchgangswiderstands unter stationären Bedingungen (sweating guarded
-hotplate test) (ISO 11092:2014)
Textiles - Effets physiologiques - Mesurage de la résistance thermique et de la
résistance à la vapeur d'eau en régime stationnaire (essai de la plaque chaude gardée
transpirante) (ISO 11092:2014)
Ta slovenski standard je istoveten z: FprEN ISO 11092 rev
ICS:
59.080.01 Tekstilije na splošno Textiles in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 11092
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2014
ICS 59.080.01 Supersedes EN 31092:1993
English Version
Textiles - Physiological effects - Measurement of thermal and
water-vapour resistance under steady-state conditions (sweating
guarded-hotplate test) (ISO 11092:2014)
Textiles - Effets physiologiques - Mesurage de la résistance Textilien - Physiologische Wirkungen - Messung des
thermique et de la résistance à la vapeur d'eau en régime Wärme- und Wasserdampfdurchgangswiderstands unter
stationnaire (essai de la plaque chaude gardée stationären Bedingungen (sweating guarded-hotplate test)
transpirante) (ISO 11092:2014) (ISO 11092:2014)
This European Standard was approved by CEN on 18 July 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11092:2014 E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
This document (EN ISO 11092:2014) has been prepared by Technical Committee ISO/TC 38 "Textiles" in
collaboration with Technical Committee CEN/TC 248 “Textiles and textile products” the secretariat of which is
held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by March 2015, and conflicting national standards shall be withdrawn at
the latest by March 2015.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 31092:1993.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11092:2014 has been approved by CEN as EN ISO 11092:2014 without any modification.
INTERNATIONAL ISO
STANDARD 11092
Second edition
2014-09-01
Textiles — Physiological effects —
Measurement of thermal and water-
vapour resistance under steady-state
conditions (sweating guarded-
hotplate test)
Textiles — Effets physiologiques — Mesurage de la résistance
thermique et de la résistance à la vapeur d’eau en régime stationnaire
(essai de la plaque chaude gardée transpirante)
Reference number
ISO 11092:2014(E)
©
ISO 2014
ISO 11092:2014(E)
© ISO 2014
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2014 – All rights reserved
ISO 11092:2014(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Terms and definitions . 1
3 Symbols and units . 2
4 Principle . 3
5 Apparatus . 3
6 Test specimens. 6
6.1 Materials ≤ 5 mm thick . 6
6.2 Materials > 5 mm thick . 6
7 Test procedure . 7
7.1 Determination of apparatus constants . 7
7.2 Assembly of test specimens on the measuring unit . 9
7.3 Measurement of thermal resistance R .
ct 9
7.4 Measurement of water-vapour resistance R .
et 10
8 Precision of results.10
8.1 Repeatability .10
8.2 Reproducibility .10
9 Test report .10
Annex A (normative) Mounting procedure for specimens containing loose filling materials or
having uneven thickness .12
Annex B (normative) Determination of correction terms for heating power .13
Annex C (informative) Guidance on test specimen assembly for materials prone to swelling .14
ISO 11092:2014(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any
patent rights identified during the development of the document will be in the Introduction and/or on
the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical Barriers
to Trade (TBT) see the following URL: Foreword - Supplementary information.
The committee responsible for this document is ISO/TC 38, Textiles.
This second edition cancels and replaces the first edition (ISO 11092:1993), which has been technically
revised. It also incorporates Amendment 1 to ISO 11092:1993 (ISO 11092:1993/Amd.1:2012).
iv © ISO 2014 – All rights reserved
ISO 11092:2014(E)
Introduction
This International Standard is the first of a number of standard test methods in the field of clothing
comfort.
The physical properties of textile materials which contribute to physiological comfort involve a complex
combination of heat and mass transfer. Each may occur separately or simultaneously. They are time-
dependent, and may be considered in steady-state or transient conditions.
Thermal resistance is the net result of the combination of radiant, conductive and convective heat
transfer, and its value depends on the contribution of each to the total heat transfer. Although it is an
intrinsic property of the textile material, its measured value may change through the conditions of test
due to the interaction of parameters such as radiant heat transfer with the surroundings.
Several methods exist which may be used to measure heat and moisture properties of textiles, each of
which is specific to one or the other and relies on certain assumptions for its interpretation.
The sweating guarded-hotplate (often referred to as the “skin model”) described in this International
Standard is intended to simulate the heat and mass transfer processes which occur next to human skin.
Measurements involving one or both processes may be carried out either separately or simultaneously
using a variety of environmental conditions, involving combinations of temperature, relative humidity,
air speed, and in the liquid or gaseous phase. Hence transport properties measured with this apparatus
can be made to simulate different wear and environmental situations in both transient and steady-
states. In this International Standard only steady-state conditions are selected.
INTERNATIONAL STANDARD ISO 11092:2014(E)
Textiles — Physiological effects — Measurement of thermal
and water-vapour resistance under steady-state conditions
(sweating guarded-hotplate test)
1 Scope
This International Standard specifies methods for the measurement of the thermal resistance and
water-vapour resistance, under steady-state conditions, of e.g. fabrics, films, coatings, foams and leather,
including multilayer assemblies, for use in clothing, quilts, sleeping bags, upholstery and similar textile
or textile-like products.
The application of this measurement technique is restricted to a maximum thermal resistance and
water-vapour resistance which depend on the dimensions and construction of the apparatus used (e.g.
2 2
2 m ·K/W and 700 m ·Pa/W respectively, for the minimum specifications of the equipment referred to
in this International Standard).
The test conditions used in this International Standard are not intended to represent specific comfort
situations, and performance specifications in relation to physiological comfort are not stated.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
thermal resistance
R
ct
temperature difference between the two faces of a material divided by the resultant heat flux per unit
area in the direction of the gradient
Note 1 to entry: It is a quantity specific to textile materials or composites which determines the dry heat flux
across a given area in response to a steady applied temperature gradient. The dry heat flux may consist of one or
more conductive, convective and radiant components.
Note 2 to entry: Thermal resistance is expressed in square metres kelvin per watt.
2.2
water-vapour resistance
R
et
water-vapour pressure difference between the two faces of a material divided by the resultant
evaporative heat flux per unit area in the direction of the gradient
Note 1 to entry: It is a quantity specific to textile materials or composites which determines the “latent” evaporative
heat flux across a given area in response to a steady applied water-vapour pressure gradient. The evaporative
heat flux may consist of both diffusive and convective components.
Note 2 to entry: Water-vapour resistance is expressed in square metres pascal per watt.
2.3
water-vapour permeability index
i
mt
ratio of thermal and water-vapour resistances in accordance with Formula (1):
R
ct
iS=⋅ (1)
mt
R
et
ISO 11092:2014(E)
where S equals 60 Pa/K
Note 1 to entry: The water-vapour permeability index is dimensionless, and has values between 0 and 1. A value
of 0 implies that the material is water-vapour impermeable, that is, it has infinite water-vapour resistance, and a
material with a value of 1 has both the thermal resistance and water-vapour resistance of an air layer of the same
thickness.
2.4
water-vapour permeability
W
d
characteristic of a textile material or composite depending on water-vapour resistance and temperature
in accordance with Formula (2):
W = (2)
d
RT⋅φ
et m
where ϕT is the latent heat of vaporization of water at the temperature T of the measuring unit,
m m
equals, for example, 0,672 W·h/g at T = 35 °C
m
Note 1 to entry: Water-vapour permeability is expressed in grams per square metre hour pascal.
3 Symbols and units
R is the thermal resistance, in square metres kelvin per watt
ct
R is the water-vapour resistance, in square metres pascal per watt
et
i is the water-vapour permeability index, dimensionless
mt
R is the apparatus constant, in square metres kelvin per watt, for the measurement of
ct0
thermal resistance R
ct
R is the apparatus constant, in square metres pascal per watt, for the measurement of
et0
water vapour resistance R
et
W is the water-vapour permeability, in grams per square meter hour pascal
d
ϕT is the latent heat of vaporization of water at the temperature T , in watt hours per gram
m m
A is the area of the measuring unit, in square metres
T is the air temperature in the test enclosure, in degrees Celsius
a
T is the temperature of the measuring unit, in degrees Celsius
m
T is the temperature of the thermal guard, in degrees Celsius
s
p is the water-vapour partial pressure, in pascals, of the air in the test enclosure at tem-
a
perature T
a
p is the saturation water-vapour partial pressure, in pascals, at the surface of the measur-
m
ing unit at temperature T
m
v is the speed of air above the surface of the test specimen, in metres per second
a
S is the standard deviation of air speed v, in metres per second
v
R.H. is the relative humidity, in percent
H is the heating power supplied to the measuring unit, in watts
2 © ISO 2014 – All rights reserved
ISO 11092:2014(E)
ΔH is the correction term for heating power for the measurement of thermal resistance R
c ct
ΔH is the correction term for heating power for the measurement of water-vapour resist-
e
ance R
et
α is the slope of the correction line for the calculation of ΔH
c
β is the slope of the correction line for the calculation of ΔH
e
4 Principle
The specimen to be tested is placed on an electrically heated plate with conditioned air ducted to flow
across and parallel to its upper surface as specified in this International Standard.
For the determination of thermal resistance, the heat flux through the test specimen is measured after
steady-state conditions have been reached.
The technique described in this International Standard enables the thermal resistance R of a material
ct
to be determined by subtracting the thermal resistance of the boundary air layer above the surface of
the test apparatus from that of a test specimen plus boundary air layer, both measured under the same
conditions.
For the determination of water-vapour resistance, an electrically heated porous plate is covered by
a water-vapour permeable but liquid-water impermeable membrane. Water fed to the heated plate
evaporates and passes through the membrane as vapour, so that no liquid water contacts the test
specimen. With the test specimen placed on the membrane, the heat flux required to maintain a constant
temperature at the plate is a measure of the rate of water evaporation, and from this the water-vapour
resistance of the test specimen is determined.
The technique described in this International Standard enables the water-vapour resistance R of a
et
material to be determined by subtracting the water-vapour resistance of the boundary air layer above
the surface of the test apparatus from that of a test specimen plus boundary air layer, both measured
under the same conditions.
5 Apparatus
5.1 Measuring unit, with temperature and water supply control, consisting of a metal plate
approximately 3 mm thick with a minimum area of 0,04 m (e.g. a square with each side 200 mm in
length, l) fixed to a conductive metal block containing an electrical heating element [see Figure 1,
items (1) and (6)]. For the measurement of water-vapour resistance, the metal plate (1) must be porous.
It is surrounded by a thermal guard [item (8) of Figure 2] which is in turn located within an opening in a
measuring table (11).
The coefficient of radiant emissivity of the plate surface (1) shall be greater than 0,35, measured at 20 °C
between the wavelengths 8 µm to 14 µm, with the primary beam perpendicular to the plate surface and
the reflection hemispherical.
Channels are machined into the face of the heating element block (6) where it contacts the porous plate
to enable water to be fed from a dosing device (5).
...