Abstract

This document specifies calculation methods for determining the required mass flow to be relieved for each specified conditions described in Table 1.
Recommendations for pressure relief devices for cryostats are given in Annex A.

Status
Published
Publication Date
20-Oct-2026
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
21-Oct-2026
Due Date
21-Oct-2026
Completion Date
21-Oct-2026

Buy Documents

Standard

EN ISO 21013-3:2026

English language (46 pages)
Preview
Preview
e-Library read for
×1 day

EN ISO 21013-3:2026 is a CEN standard for cryogenic vessels that covers pressure-relief accessories for cryogenic service. It specifies calculation methods for the mass flow that must be relieved under defined conditions, so designers can size pressure relief valves and bursting discs and check the effect of piping, heat leak, loss of vacuum, and fire cases.

What does EN ISO 21013-3:2026 specify?

EN ISO 21013-3:2026 specifies separate calculation methods for determining the required mass flow to be relieved for the conditions listed in the standard’s condition table. It also gives recommendations for pressure relief devices for cryostats in Annex A.

The document is organized into:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Symbols
  • Clause 4 Heat transfer calculations
  • Clause 5 Mass flow to be relieved
  • Clause 6 Piping for pressure relief devices
  • Clause 7 Sizing of pressure relief devices
  • Annex A on cryostats
  • Annex ZA on the relationship with the Pressure Equipment Directive
  • Bibliography
AnnexWhat it covers
Annex ACryostats and design recommendations for their pressure relief devices
Annex ZARelationship between this European Standard and Directive 2014/68/EU

In practice, the standard is about turning operating and upset conditions into a required discharge capacity, then using that requirement to size the relief system.

What are the key requirements of EN ISO 21013-3:2026?

EN ISO 21013-3:2026 builds the sizing method in three steps: estimate heat input, convert that heat input into required mass flow, then verify that the complete relief path can pass that flow. The clause structure matters because it separates vessel heat loads, piping effects, and the final device sizing.

Heat transfer cases in Clause 4

Clause 4 covers the heat transferred from the warm side to the cold side of the vessel in the main service cases. EN ISO 21013-3:2026 distinguishes normal operation, pressure build-up device operation, loss of vacuum, fire exposure, and air or nitrogen condensation.

In practice, this means you do not size a relief device from one generic heat load. You choose the case that matches the vessel construction and upset condition, because different insulation states and different ambient conditions can change the required relieving capacity.

Fire and pressure build-up conditions

Clause 4 treats fire as a separate case, using an external fire temperature of 922 K, and it also requires pressure build-up device conditions to be considered. The text notes that fire may not be the worst case, so fire and PBU conditions both have to be checked.

In practice, a vessel that is safe for normal service can still need a larger relief system for fire exposure or for a pressure build-up circuit. If the PBU arrangement changes later in the field, the sizing needs to be reviewed again.

Loss of vacuum and low-temperature condensation

Clause 4 also covers loss of vacuum and, for fluids with a saturation temperature below 75 K at 1 bar, air or nitrogen condensation. The document applies this to multi-layer insulated containers and gives guidance for handling other insulation types.

In practice, this matters for very cold fluids such as liquid hydrogen. The relief load may be governed by condensation and insulation performance rather than by the vessel contents alone.

Converting heat load to mass flow in Clause 5

Clause 5 turns total heat transfer into the mass flow to be relieved. For pressures below the critical pressure, the method is based on heat input or on normal evaporation rate. For pressures at or above the critical pressure, it uses the relieving temperature approach with thermophysical properties.

In practice, the relieving pressure determines which calculation route to use. That choice affects the discharge rate that must be met by the relief device.

Piping effects in Clause 6

Clause 6 requires pressure drop, back pressure, and heat transfer in the piping to be taken into account. The text also says that if piping between the outer jacket and the safety relief device is longer than 0.6 m, heat transfer to the flowing fluid must be included.

In practice, the relief valve or bursting disc cannot be sized in isolation. The upstream and downstream piping can reduce capacity, increase back pressure, and change the fluid temperature before discharge.

Final sizing in Clause 7

Clause 7 gives separate sizing methods for pressure relief valves and bursting discs. It distinguishes critical and subcritical gas flow, requires the selected device capacity to meet or exceed the required mass flow, and explains how to combine multiple devices when they discharge together.

In practice, the selected orifice or net flow area must match the actual system conditions, including inlet pressure drops and outlet back pressure. For bursting discs, the flow resistance of the complete pipe network is part of the sizing check.

Cryostat-specific guidance in Annex A

Annex A adds cryostat-specific recommendations. It says to include heat generated by upset process conditions, and it gives design advice on gas space volume, set pressure, outlet pressure, and certified flow area after rupture for bursting discs.

In practice, cryostats can need extra attention because process upsets can add heat load and create mixed flow in the relief piping.

What terms does EN ISO 21013-3:2026 define?

  • NER - Normal evaporation rate, the fraction of vessel mass that evaporates per day and can be used as an alternate basis for heat leak.
  • PBU - Pressure build-up, the condition where a pressure build-up device adds heat input to the system.
  • Relieving pressure, P - The absolute inner-vessel pressure used to calculate required relief capacity.
  • Critical flow - A gas or vapour flow regime where lowering outlet pressure no longer increases discharge capacity.
  • Subcritical flow - A gas flow regime where outlet pressure still influences the discharge capacity.
  • Built-up back pressure - The pressure rise at the relief outlet caused by flow through the downstream piping and fittings.
  • Coefficient of discharge, Kd - The discharge coefficient used in valve capacity calculations, with a derated form used in the sizing equations.

Who uses EN ISO 21013-3:2026?

EN ISO 21013-3:2026 is used by engineers who design cryogenic vessels, pressure-relief systems, and the piping connected to them. It is also used by manufacturers and suppliers of pressure relief valves and bursting discs when they need to rate device capacity for a specific cryogenic application.

Quality managers, buyers, and certifiers use it to check that a proposed relief system has been sized against the correct vessel condition and that piping effects have been considered. It is particularly relevant in cryogenic industries such as liquid hydrogen, helium, nitrogen, oxygen, and other low-temperature storage and transport applications. Cryostat designers use Annex A when the vessel protects low-temperature test or operating equipment such as superconducting devices.

What changed in EN ISO 21013-3:2026 from the previous edition?

EN ISO 21013-3:2026 is the third edition and it cancels and replaces ISO 21013-3:2016. The foreword says the document was technically revised.

The changes stated in the document are:

  • precision added on the total outer surface area of the pipe network containing flow of fluid
  • inclusion of the coefficient of discharge symbol
  • precision added on the overall convective heat transfer coefficient of the ambient air vaporizer
  • additional information added on the fire case and PBU conditions
  • correction of the molar mass in kg/kmol and modification of formulas 32 and 43
  • supplementary information added on cryostats

Which standards are used with EN ISO 21013-3:2026?

The document lists no normative references. Its bibliography names these related pressure-relief standards:

  • ISO 4126-1 - safety valves for protection against excessive pressure
  • ISO 4126-6 - application, selection, and installation of bursting disc safety devices
  • ISO 4126-10 - sizing of safety valves and bursting discs for gas/liquid two-phase flow

These references help readers place EN ISO 21013-3:2026 in the wider pressure-relief family, especially when comparing valve sizing, disc selection, and two-phase flow practice.

What does the EN ISO 21013-3:2026 document contain?

EN ISO 21013-3:2026 contains the calculation framework, symbols, thermophysical-property tables, and worked methods needed to size relief devices for cryogenic vessels. It includes tables for fluid properties, pipe friction and transition resistance, and flow coefficients used in the sizing equations.

The document also contains a figure for air or nitrogen condensation, examples for relief valve sizing and bursting disc sizing, and detailed pipe-network analysis steps. Annex A adds cryostat-specific design guidance, while Annex ZA maps the European standard to Directive 2014/68/EU for pressure equipment.

Relations

Effective Date
18-Jan-2023
Effective Date
28-Oct-2026
Effective Date
28-Oct-2026
Effective Date
28-Oct-2026
Effective Date
28-Oct-2026
Effective Date
12-Feb-2026

Buy Documents

Standard

EN ISO 21013-3:2026

English language (46 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Institut za varilstvo d.o.o. (Welding Institute)

Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN ISO 21013-3:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Cryogenic vessels - Pressure-relief accessories for cryogenic service - Part 3: Sizing and capacity determination (ISO 21013-3:2026)". This standard covers: This document specifies calculation methods for determining the required mass flow to be relieved for each specified conditions described in Table 1. Recommendations for pressure relief devices for cryostats are given in Annex A.

This document specifies calculation methods for determining the required mass flow to be relieved for each specified conditions described in Table 1. Recommendations for pressure relief devices for cryostats are given in Annex A.

EN ISO 21013-3:2026 is classified under the following ICS (International Classification for Standards) categories: 23.020.40 - Cryogenic vessels. The ICS classification helps identify the subject area and facilitates finding related standards.

EN ISO 21013-3:2026 has the following relationships with other standards: It is inter standard links to EN ISO 21013-3:2016, EN 13648-2:2002, EN 14398-1:2003, EN 14398-2:2003+A2:2008, EN 13458-2:2002, ISO 21013-3:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN ISO 21013-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2008/68/EC, 2014/68/EU; Standardization Mandates: M/071, M/601, M/TDG. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN ISO 21013-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and symbols
  • 3.1 Symbols
  • 4 Calculation of the total quantity of heat transferred per unit time from the hot wall
  • 4.1 General
  • 4.2 Under conditions other than fire
  • 4.3 Under fire conditions
  • 4.4 Air or nitrogen condensation
  • 4.5 Heat transfer per unit time (watts)
  • 5 Calculation of the mass flow to be relieved by pressure relief devices
  • 5.1 Relieving pressure, P, less than the critical pressure
  • 5.2 Relieving pressure, P, equal to or greater than the critical pressure
  • 5.3 Example
  • 6 Piping for pressure relief devices
  • 6.1 Pressure drop
  • 6.2 Back pressure consideration
  • 6.3 Heat transfer
  • 7 Sizing of pressure relief devices
  • 7.1 General
  • 7.2 Sizing of pressure relief valves
  • 7.3 Sizing of bursting discs
  • Annex A
  • Bibliography

1 Scope

This document specifies calculation methods for determining the required mass flow to be relieved for each specified conditions described in Table 1.

a Table 1 — Subclause required for calculating mass flow rate based on specified condition Insulation Type of system (outer Pressure Use clauses insu- Vacuum Inner vessel jacket + Ambient buildup Condition including any lation status temperature insulating conditions system subclauses system material) condition condition normal (ambient 4.2.3,4.2.4, 4.5.1, 1 intact tempera- 4.5.2, 4.5.7, 5, 6, 7 nonture) N/A vacuum normal fully or condition 4.3.1, 4.5.1, 4.5.7, 5, 2 partially in fire (922 K) 6, 7 tempera- place ture of the 4.2.1, 4.2.4, 4.5.1,

contents at 4.5.2, 4.5.7, 5, 6, 7 the specified normal normal 4.2.1, 4.2.2, 4.2.4, relieving (ambient 4 intact full open 4.5.1, 4.5.3, 4.5.7, 5, pressure tempera- 6, 7 ture) 4.2.3, 4.2.4, 4.5.1,

4.5.4, 4.5.7 ,5, 6, 7 loss of fully or vacuum vacuum 4.3.1, 4.4.3, 4.5.1, 6 partially in fire (922 K) 4.5.5, 4.5.7, 5, 6, 7 place normal (ambient 4.4.2, 4.5.1, 4.5.4, 7 normal loss of tempera- 4.5.7, 5, 6 ,7 condition intact vacuum ture) contents with with air or relieving 4.4.3, 4.5.1, 4.5.5, 8 nitrogen temperature 4.5.7, 5, 6, 7 in the below 75 K Vacuum vacuum fire (922 K) and 4.5.1, 4.5.6, 4.5.7, 5, space 9 totally lost non- 6, 7 vacuum When no appropriate calculation method is provided for a condition, the required mass flow is determined using good engineering practice based on well-established theoretical physical science. Recommendations for pressure relief devices for cryostats are given in Annex A.

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en)

2 Normative references

There are no normative references in this document.

3 Terms, definitions and symbols

No terms and definitions are listed in this document.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 Symbols

A arithmetic mean of inner and outer surface areas of vessel insulating material m

A actual flow area of a pipe element m B

A total outer surface area of the pipe network containing flow of fluid, from the outer m e jacket up to the flow temperature location x under consideration; applicable only when l > 0,6 m (See 6.1.1)

A minimum flow area (reference area) in a pipe network m F

A minimum flow area (reference area) in the pipe network, downstream of relief valve m Fd

A minimum flow area (reference area) in the pipe network, upstream of relief valve m Fu

A total outside surface area of inner vessel m

A total outer surface area of pipe network between the inner and outer jackets m j (interspace)

A larger flow area of a pipe element containing two different flow area sizes m L

A cross-sectional area, support, or pipe material m n A area ratio, A /A — R S L

A smaller flow area of a pipe element containing two different flow area sizes m S

A actual flow (orifice) area of a pressure relief valve mm V

A actual flow (orifice) area of pressure relief valve selected for final analysis mm Va

A minimum required relief valve flow (orifice) area mm V1

A external heat transfer surface area of ambient air vaporizer m

C experimentally determined flow rate through a pipe element or device m /h V K flow resistance coefficient of a pipe element in terms of A — A F K flow resistance coefficient of a pipe element in terms of A — B B K subcritical flow coefficient — b K coefficient of discharge — d

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en) K derated coefficient of discharge — dr K derated coefficient of discharge of next largest available valve orifice area greater — dr,a than A V1 K derated coefficient of discharge of initially analysed valve — dr,1 K flow resistance coefficient of complete pipe network in terms of reference area, A — R F K flow resistance coefficient at the transition between critical and subcritical flow — RC K overall flow resistance coefficient of pipe network, downstream of pressure relief — Rd valve K overall flow resistance coefficient of pipe network, upstream of pressure relief valve — Ru K total flow resistance coefficient of a series or parallel pipe network — SUM 3 1) K experimentally determined flow rate through a pipe element or device m /h/bar V L latent heat of vaporization of cryogenic liquid at relieving conditions kJ/kg 1) L latent heat of vaporization of cryogenic liquid at a pressure of 1,013 bar kJ/kg a L’ enthalpy-to-volume expansion ratio for critical or all-gas fluid flow conditions kJ/kg M molar mass kg/kmol N normal evaporation rate (NER) %/day P relieving pressure, inner vessel in absolute pressure bar P pressure, safety relief valve outlet in absolute pressure bar b P pressure at relief valve outlet for a downstream built-up backpressure of 10 % bar b10 P pressure at pipe network exit in absolute pressure bar exit P pressure, safety relief valve inlet in absolute pressure bar

P pressure relief valve set pressure in absolute pressure bar S Q mass flow rate kg/h m Q mass flow rate of a relief valve within a given pipe network kg/h ma Q mass flow rate due to the normal evaporation rate kg/h mNER R universal gas constant J/(mol·K) T relieving temperature, inner vessel K T maximum external ambient temperature, non-fire condition K a T temperature at relief valve outlet K b,Pb T temperature at relief valve outlet for a downstream built-up backpressure of 10 % K b10 T external temperature for a given condition K e 5 2 1) bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm .

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en) T temperature at pipe network exit K exit,Pb T external temperature, fire condition K f T temperature, safety relief valve inlet K

T temperature of fluid at a given flow start location along the pipe network K n T saturation temperature of fluid at a pressure of 1 bar K sat T temperature of fluid at a given location x along the pipe network K

U heat transfer coefficient of insulating material, normal vacuum, non-fire condition W/ (m ·K)

U overall convective heat transfer coefficient of ambient air vaporizer W/ (m ·K)

U heat transfer coefficient of insulating material with air or gaseous lading, non-fire W/ (m ·K)

condition

U heat transfer coefficient, air or nitrogen condensation, loss of vacuum, non-fire W/m 3a condition

U heat transfer coefficient of insulating material with air or gaseous lading, fire W/ (m ·K)

condition

U heat transfer coefficient, air or nitrogen condensation, loss of vacuum, fire condition W/m 5a

U overall heat transfer coefficient of a pipe network for given temperature conditions W/ (m ·K) p W total heat transfer rate for specified conditions Watt [W] T W total heat transfer rate under normal operation Watt [W] T1 W total NER heat transfer rate under normal operation Watt [W] T1NER W total heat transfer rate under normal operation, including pressure build-up device Watt [W] T2 W total NER heat transfer rate under normal operation, including pressure build-up Watt [W] T2NER device W total heat transfer rate, loss of vacuum, insulation in place, non-fire condition, Watt [W] T3 T ˃ 75 K sat W total heat transfer rate, loss of vacuum, insulation in place, non-fire condition, Watt [W] T3a T ≤ 75 K sat W total heat transfer rate, loss of vacuum, insulation in place, fire condition, T ˃ 75 K Watt [W] T5 sat W total heat transfer rate, loss of vacuum, insulation in place, fire condition, T ≤ 75 K Watt [W] T5a sat W total heat transfer rate, loss of vacuum, insulation not in place, fire condition Watt [W] T6 W heat transfer rate through insulation system, normal vacuum, non-fire condition Watt [W]

W heat transfer rate through pressure build-up device, fully open regulator Watt [W]

W heat transfer rate through insulation system, loss of vacuum, non-fire condition Watt [W]

W heat transfer rate through air or nitrogen condensation, loss of vacuum, Watt [W] 3a non-fire condition W heat transfer rate through interspace supports and piping Watt [W]

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en) W heat transfer rate through vessel walls, insulation in place, fire condition Watt [W]

W heat transfer rate through air or nitrogen condensation, loss of vacuum, Watt [W] 5a fire condition W heat transfer rate through vessel walls, insulation not in place, fire condition Watt [W]

X number of insulation layers — Y heat transfer rate U or U — 3a 5a Z compressibility factor at pressure P and temperature T — i i i a c constant pressure specific heat capacity at the average of T and T kJ/(kg·K) p n e e nominal insulating material thickness, in normal vacuum, non-fire condition m

e minimum insulating material thickness, considering loss of vacuum, non-fire m

condition e insulating material thickness remaining in place during fire conditions m

f pipe flow friction coefficient — T h enthalpy of fluid at conditions of ν kJ/kg h specific enthalpy at relief valve inlet and outlet kJ/kg r k mean thermal conductivity of insulating material, normal vacuum, W/(m·K)

non-fire condition k mean thermal conductivity of insulating material with air or gaseous lading, W/(m·K)

non-fire condition k mean thermal conductivity of an individual support or pipe, between T and T W/(m·K) n a l length, pipe element m l length of support or pipe in vacuum interspace m n m maximum mass capacity of vessel kg max r pipe elbow transition radius m x lengthwise location along a pipe network m φ — PP P exit exit pressure ratio 1 P P κ isentropic exponent — λ subcritical flow coefficient —

ν specific volume of critical or all-gas fluid at a given temperature at pressure P m /kg

ν specific volume at relief valve outlet for a downstream built-up backpressure of 10 % m /kg b10

ν specific volume at pressure relief valve outlet, evaluated at h and a trial value of P m /kg b,Pb r b

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en)

ν average downstream specific volume, for a downstream built-up backpressure m /kg d10 of 10 %

ν maximum average downstream specific volume, as per desired backpressure limit m /kg dmax

ν specific volume at pipe network exit for a downstream built-up backpressure of 10 % m /kg exit10

ν specific volume at pipe network exit, evaluated at P and T m /kg exit,Pb exit exit,Pb

ν specific volume of saturated gas at relieving pressure, P m /kg g

ν specific volume of saturated gas at a pressure of 1,013 bar m /kg ga

ν specific volume, safety relief valve inlet m /kg

ν specific volume of saturated liquid at relieving pressure, P m /kg

ν specific volume of saturated liquid at a pressure of 1,013 bar m /kg la

ν average specific volume of flowing fluid upstream of pressure relief valve inlet m /kg u 3/2 1/2 ψ expression for determining Q and T for critical or gas-full-vessel fluid flow m ·kg / m conditions kJ

4 Calculation of the total quantity of heat transferred per unit time from the hot wall

(outer jacket) to the cold wall (inner vessel)

4.1 General

P (in bar absolute) is the actual relieving pressure inside the vessel which is used for calculating the required mass flow through pressure relief devices.

T (in K) is the maximum ambient temperature for conditions other than fire (as specified, for example, by a a regulation or standard).

T (in K) is the external environment temperature under fire conditions which is taken to be 922 K in this f document.

T (in K) is the relieving temperature in the vessel to be taken into account. a) For subcritical fluids, T is the saturation temperature of the liquid at pressure P. b) For critical or supercritical fluids, T is calculated from 5.2.

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en)

4.2 Under conditions other than fire

4.2.1 Vacuum-insulated vessels under normal vacuum

W is the quantity of heat transferred per unit time (in watts) by heat leak through the insulation system, as

per Formula (1).

WUAT T (1)

11 a where U is the overall heat transfer coefficient of the insulating material under normal vacuum, in W/

k

(m ⋅K): U = ;

e

k is the mean thermal conductivity of the insulating material under normal vacuum, between T

and T , in W/(m⋅K); a e is the nominal insulating material thickness, in m;

A is the arithmetic mean of the inner and outer surface areas of the vessel insulating material, in

m ; T is the relieving temperature, inner vessel; T is the maximum external ambient temperature, non-fire condition. a

4.2.2 Pressure build-up device

W is the quantity of heat transferred per unit time (in watts) by the pressure build-up device circuit with

the regulator fully open. W is determined from the type (ambient air, water or steam, electrical, etc.) and

design of the pressure build-up device circuit. For example, in the case of an ambient air vaporizer, W is

calculated using Formula (2):

WUAT T (2)

22 2 a where

U is the overall convective heat transfer coefficient of the ambient air vaporizer, in W/(m ⋅K);

A is the external heat transfer surface area of the vaporizer, in m ;

T is the relieving temperature, inner vessel; T is the maximum external ambient temperature, non-fire condition. a As a first approximation, Formula (3) or Formula (4) may be used:

UT TT19 000 W/mfor 75K (3)

2 a

UT TT2 850 W/mfor 75K (4)

2 a U shall not be lower than the values proposed but manufacturers can use greater values if their design

requires.

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en)

4.2.3 Vacuum-insulated vessels in the case of loss of vacuum and non-vacuum insulated vessels

W is the quantity of heat transferred per unit time (in watts) by heat leak through the insulating material. It

is calculated using Formula (5):

WUAT T (5)

33 a where U is the overall heat transfer coefficient of the insulating material when saturated with

gaseous lading or air at atmospheric pressure, whichever is greater, in W/(m ·K); T is the relieving temperature, inner vessel; T is the maximum external ambient temperature, non-fire condition; a A is the arithmetic mean of inner and outer surface areas of vessel insulating material. If the insulation is fully effective for conduction, convection, and radiation heat transfer at 328 K, U may be

calculated using Formula (6):

k

U = (6)

e

where k is the mean thermal conductivity of the insulating material saturated with gaseous lading

or air at atmospheric pressure, whichever provides the greater coefficient, between T and T , in W/(m·K) (values of k for gases are listed in Table 2); a 3 e is the minimum insulating material thickness taking into account the manufacturing

tolerances or effects of sudden loss of vacuum, in m.

NOTE This formula might not be applicable at temperatures below 75 K with a small thickness of insulating material as the maximum heat transfer coefficient would be given by air condensation. Vacuum space, gas space, or space occupied by the deteriorated insulation shall not be included in the thickness of the insulation. The effectiveness of these spaces or deteriorated insulation in reducing conduction, convection, or radiation heat transfer may be evaluated separately and included in the overall heat transfer coefficient, U , using methods found in published heat transfer literature. Deterioration of the

insulation can be caused by the following:

  • moisture condensation;
  • air condensation;
  • increase in the density of the insulation due to a sudden loss of vacuum.

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en) Table 2 — Thermal conductivity for refrigerated (cryogenic) fluids at the mean temperature between saturation and 328 K (k) and 922 K (k) at 1 bar 3 5 k k 3 5 Fluid [W/(m·K)] [W/(m·K)] Air 0,019 0,043 Argon 0,013 0,027 Carbon dioxide 0,017 0,039 Carbon monoxide 0,020 0,039 Helium 0,104 0,211 Hydrogen 0,116 0,217 Methane 0,024 0,074 Neon 0,034 0,067 Nitrogen 0,019 0,040 Oxygen 0,019 0,043 Krypton 0,007 0,015 Xenon 0,005 0,009 Ethane 0,016 0,064 Trifluoromethane 0,012 0,027 Ethylene (ethene) 0,015 0,056 Nitrous oxide 0,014 0,038 Values are for reference only. Use fluid properties given in current databases, such as from NIST.

4.2.4 Supports and piping

W is the quantity of heat transferred per unit time (in watts) by supports and piping located in the

interspace, given by Formula (7):

WwwwwT T (7)

41 23 na where w is the heat leak per degree K contributed by one of the supports or the pipes, in W/K, given by n Formula (8):

 A  n wk (8)

nn

n where k is the mean thermal conductivity of the support or pipe material between T and T , in n a W/(m⋅K);

A is the support or pipe section area, in m ; n l is the support or pipe length in the vacuum interspace, in m. n

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en)

4.3 Under fire conditions

4.3.1 Insulation system remains fully or partially in place during fire conditions

W is the quantity of heat transferred per unit time (in watts) by heat leak through the vessel walls, given by

Formula (9):

08, 2 WT26, 922 UA (9)

where if the insulation is fully effective for conduction, convection, and radiation heat transfer for an external temperature of 922 K, U may be calculated using Formula (10):

k

U = (10)

e

where U is the overall heat transfer coefficient of the container-insulating material when saturated

with gaseous lading or air at atmospheric pressure, whichever is greater, in W/(m ·K); k is the mean thermal conductivity of the insulating material saturated with gaseous lading

or air at atmospheric pressure, whichever provides the greater coefficient, between T and 922 K, in W/(m·K) (values of k for gases are listed in Table 2);

e is the thickness of the insulating material remaining in place during fire conditions, in m;

A is the arithmetic mean of the inner and outer surface areas of the insulating material

remaining in place during fire conditions, in m ; T is the relieving temperature, inner vessel.

Vacuum space, gas space, or space occupied by the deteriorated insulation shall not be included in the thickness of the insulation. The effectiveness of these spaces or deteriorated insulation in reducing conduction, convection, or radiation heat transfer may be evaluated separately and included in the overall heat transfer coefficient, U , using methods found in published heat transfer literature. Deterioration of the

insulation can be caused by the following:

  • moisture condensation;
  • air condensation;
  • increase in the density of the insulation due to a sudden loss of vacuum;
  • degradation due to heat.

If the outer jacket remains in place during fire conditions, but the insulating material is entirely destroyed, U is equal to the overall heat transfer coefficient with gaseous lading or air at atmospheric pressure in the

space between the outer jacket and the inner vessel, whichever provides the greater coefficient, between T and 922 K. A is equal to the mean surface area of the interspace.

4.3.2 Insulation system does not remain in place during fire conditions

W is the quantity of heat transferred per unit time (in watts) by heat leak through the vessel walls,

calculated using Formula (11):

40,82 WA71, 10  (11) 6 i

where A is the total outside surface area of the inner vessel, in m .

SIST EN ISO 21013-3:2026 ISO 21013-3:2026(en) The heat transferred by supports and piping located in the interspace can be neglected in this case.

4.4 Air or nitrogen condensation

4.4.1 General

The air or nitrogen condensation case for the loss of vacuum condition shall be considered for fluids with a saturation temperature below 75 K at 1 bar.

...