ASTM D7458-21
(Test Method)Standard Test Method for Determination of Beryllium in Soil and Sediment Using Ammonium Bifluoride Extraction and Fluorescence Detection
Standard Test Method for Determination of Beryllium in Soil and Sediment Using Ammonium Bifluoride Extraction and Fluorescence Detection
SIGNIFICANCE AND USE
5.1 Exposure to beryllium can cause a potentially fatal disease, and occupational exposure limits for beryllium in air and on surfaces have been established to reduce exposure risks to potentially affected workers (1, 2).5 Measurement of beryllium in matrices such as soil and sediment is important in environmental remediation projects involving beryllium contamination (3) and for establishment of background levels of beryllium at sites where anthropogenic beryllium may have been used (2, 4-6). Sampling and analytical methods for beryllium are needed in order to meet the challenges relating to exposure assessment and risk reduction. Sampling and analysis methods, such as the procedure described in this test method, are desired in order to facilitate measurements of beryllium that can be used as a basis for management of remediation projects and protection of human health.
5.2 This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil.
5.3 The limit of quantification of this test method varies with the dilution factor (see 13.6.1). For the detection solution containing lysine the detection limit is 0.013 mg beryllium per kilogram of sample, based on a 0.5 g sample (7) extracted in a 50 mL extraction solution and analyzed using a dilution factor of 20×. When the lysine-free detection solution is used one may use a 20× dilution factor and obtain the same detection limit or use 5× dilution factor and obtain a detection limit of 0.004 mg/kg of sample.
Note 1: Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
SCOPE
1.1 This test method is intended for use in the determination of beryllium in samples of soil and sediment. This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil.
1.2 This test method assumes that samples of soil or sediment are collected using appropriate and applicable methods.
1.3 This test method includes a procedure for extraction (dissolution) of beryllium in dilute ammonium bifluoride, followed by analysis of aliquots of the extract solution using a beryllium-specific fluorescent dye.
1.4 For a 500 mg sample, the lower limit of the working range is approximately 0.04 mg Be/kg (5× dilution) or 0.1 mg Be/kg (20× dilution). The working range extends to concentrations of at least 500 mg Be/kg.
1.5 No detailed operating instructions are provided because of differences among various makes and models of suitable fluorometric instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument. This test method does not address comparative accuracy of different devices or the precision between instruments of the same make and model.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.
1.7.1 For purposes of comparing a measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal of significant digits in the specified limit.
1.7.2 The procedures used to specify how data are collected/recorded, or calculated, in thi...
General Information
- Status
- Published
- Publication Date
- 31-Aug-2021
- Technical Committee
- D22 - Air Quality
- Drafting Committee
- D22.04 - Workplace Air Quality
Relations
- Effective Date
- 01-Feb-2024
- Effective Date
- 01-Nov-2023
- Effective Date
- 01-Sep-2020
- Effective Date
- 15-Mar-2020
- Effective Date
- 01-Oct-2019
- Effective Date
- 15-Aug-2018
- Effective Date
- 01-Dec-2016
- Effective Date
- 01-Dec-2016
- Effective Date
- 15-Oct-2015
- Effective Date
- 01-Jul-2015
- Effective Date
- 01-May-2015
- Effective Date
- 01-Dec-2014
- Effective Date
- 01-Aug-2014
- Effective Date
- 01-May-2014
- Effective Date
- 01-May-2014
Overview
ASTM D7458-21 is a recognized international standard developed by ASTM International for the determination of beryllium in soil and sediment. This test method utilizes ammonium bifluoride extraction followed by fluorescence detection to quantify beryllium concentrations. Given beryllium’s hazardous nature and the stringent occupational exposure limits imposed due to its toxicity, precise detection and measurement in environmental matrices are crucial for environmental health and safety, especially in contaminated sites or locations of former beryllium use.
Key Topics
Purpose and Significance
Exposure to beryllium can result in serious health effects, including potentially fatal diseases. Monitoring and quantification in soil, sediment, and related matrices are essential for environmental remediation, site characterization, risk assessment, and compliance with health regulations.Scope and Applicability
- Determination of beryllium in:
- Soil
- Sediment
- Applicable for environmental remediation, mining, manufacturing sites, and background studies.
- Determination of beryllium in:
Test Method Summary
- Extraction: Samples (typically 0.5 g) are digested in a 3% ammonium bifluoride solution at 90°C for 40 hours.
- Detection: Aliquots of the extract are measured using a beryllium-specific fluorescent dye in a calibrated fluorometer.
- Quantification limits: Method detection limits can be as low as 0.004 mg/kg, depending on dilution factors and detection reagent used.
Precision and Calibration
The method requires proper calibration with multiple standards, ensuring reliable and accurate results across a wide working range.Safety Considerations
Special precautions are necessary due to the toxicity and corrosiveness of chemicals involved, particularly ammonium bifluoride and potential production of hydrofluoric acid during processing.
Applications
ASTM D7458-21 provides practical value in various fields, especially where beryllium contamination is a concern:
Environmental Remediation
Supports site assessments for hazardous waste cleanup, helping identify and quantify beryllium concentrations for regulatory compliance and remediation planning.Mining and Industry Compliance
Used in establishing baseline and operational levels of beryllium at mining or manufacturing sites, especially where beryllium was processed or used historically.Risk Assessment and Monitoring
Facilitates occupational and environmental risk assessments by enabling accurate background and site-specific beryllium level determinations in soils and sediments.Research and Site Characterization
Supports environmental studies assessing contamination transport, distribution, or long-term monitoring of remediated sites.
Related Standards
For best practices and reliable analysis, ASTM D7458-21 is often used alongside other standards:
- ASTM D3740: Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction.
- ASTM D653 and D1356: Terminology relating to soils, rocks, and atmospheres.
- ASTM D4753: Guide for evaluating, selecting, and specifying laboratory balances.
- ASTM D4840: Guide for sample chain-of-custody procedures.
- ASTM D7202: Test method for determining beryllium by extraction and optical fluorescence detection.
- ISO 594-2: Conical fittings for syringes, ensuring standardization of sampling apparatus.
Conclusion
ASTM D7458-21 ensures a consistent, reliable approach for the measurement of beryllium in soil and sediment using advanced extraction and fluorescence techniques. Its implementation is vital for environmental health professionals, remediation project managers, industrial hygienists, and laboratory analysts seeking to manage beryllium contamination risk and ensure compliance with environmental and occupational health regulations. The standard’s compatibility with other ASTM standards further enhances its practical value for accurate beryllium analysis in a wide range of environmental applications.
Buy Documents
ASTM D7458-21 - Standard Test Method for Determination of Beryllium in Soil and Sediment Using Ammonium Bifluoride Extraction and Fluorescence Detection
REDLINE ASTM D7458-21 - Standard Test Method for Determination of Beryllium in Soil and Sediment Using Ammonium Bifluoride Extraction and Fluorescence Detection
Get Certified
Connect with accredited certification bodies for this standard

NSF International
Global independent organization facilitating standards development and certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Sponsored listings
Frequently Asked Questions
ASTM D7458-21 is a standard published by ASTM International. Its full title is "Standard Test Method for Determination of Beryllium in Soil and Sediment Using Ammonium Bifluoride Extraction and Fluorescence Detection". This standard covers: SIGNIFICANCE AND USE 5.1 Exposure to beryllium can cause a potentially fatal disease, and occupational exposure limits for beryllium in air and on surfaces have been established to reduce exposure risks to potentially affected workers (1, 2).5 Measurement of beryllium in matrices such as soil and sediment is important in environmental remediation projects involving beryllium contamination (3) and for establishment of background levels of beryllium at sites where anthropogenic beryllium may have been used (2, 4-6). Sampling and analytical methods for beryllium are needed in order to meet the challenges relating to exposure assessment and risk reduction. Sampling and analysis methods, such as the procedure described in this test method, are desired in order to facilitate measurements of beryllium that can be used as a basis for management of remediation projects and protection of human health. 5.2 This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil. 5.3 The limit of quantification of this test method varies with the dilution factor (see 13.6.1). For the detection solution containing lysine the detection limit is 0.013 mg beryllium per kilogram of sample, based on a 0.5 g sample (7) extracted in a 50 mL extraction solution and analyzed using a dilution factor of 20×. When the lysine-free detection solution is used one may use a 20× dilution factor and obtain the same detection limit or use 5× dilution factor and obtain a detection limit of 0.004 mg/kg of sample. Note 1: Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors. SCOPE 1.1 This test method is intended for use in the determination of beryllium in samples of soil and sediment. This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil. 1.2 This test method assumes that samples of soil or sediment are collected using appropriate and applicable methods. 1.3 This test method includes a procedure for extraction (dissolution) of beryllium in dilute ammonium bifluoride, followed by analysis of aliquots of the extract solution using a beryllium-specific fluorescent dye. 1.4 For a 500 mg sample, the lower limit of the working range is approximately 0.04 mg Be/kg (5× dilution) or 0.1 mg Be/kg (20× dilution). The working range extends to concentrations of at least 500 mg Be/kg. 1.5 No detailed operating instructions are provided because of differences among various makes and models of suitable fluorometric instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument. This test method does not address comparative accuracy of different devices or the precision between instruments of the same make and model. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. 1.7.1 For purposes of comparing a measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal of significant digits in the specified limit. 1.7.2 The procedures used to specify how data are collected/recorded, or calculated, in thi...
SIGNIFICANCE AND USE 5.1 Exposure to beryllium can cause a potentially fatal disease, and occupational exposure limits for beryllium in air and on surfaces have been established to reduce exposure risks to potentially affected workers (1, 2).5 Measurement of beryllium in matrices such as soil and sediment is important in environmental remediation projects involving beryllium contamination (3) and for establishment of background levels of beryllium at sites where anthropogenic beryllium may have been used (2, 4-6). Sampling and analytical methods for beryllium are needed in order to meet the challenges relating to exposure assessment and risk reduction. Sampling and analysis methods, such as the procedure described in this test method, are desired in order to facilitate measurements of beryllium that can be used as a basis for management of remediation projects and protection of human health. 5.2 This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil. 5.3 The limit of quantification of this test method varies with the dilution factor (see 13.6.1). For the detection solution containing lysine the detection limit is 0.013 mg beryllium per kilogram of sample, based on a 0.5 g sample (7) extracted in a 50 mL extraction solution and analyzed using a dilution factor of 20×. When the lysine-free detection solution is used one may use a 20× dilution factor and obtain the same detection limit or use 5× dilution factor and obtain a detection limit of 0.004 mg/kg of sample. Note 1: Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors. SCOPE 1.1 This test method is intended for use in the determination of beryllium in samples of soil and sediment. This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing applications, and for determination of background levels of beryllium in soil. 1.2 This test method assumes that samples of soil or sediment are collected using appropriate and applicable methods. 1.3 This test method includes a procedure for extraction (dissolution) of beryllium in dilute ammonium bifluoride, followed by analysis of aliquots of the extract solution using a beryllium-specific fluorescent dye. 1.4 For a 500 mg sample, the lower limit of the working range is approximately 0.04 mg Be/kg (5× dilution) or 0.1 mg Be/kg (20× dilution). The working range extends to concentrations of at least 500 mg Be/kg. 1.5 No detailed operating instructions are provided because of differences among various makes and models of suitable fluorometric instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument. This test method does not address comparative accuracy of different devices or the precision between instruments of the same make and model. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. 1.7.1 For purposes of comparing a measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal of significant digits in the specified limit. 1.7.2 The procedures used to specify how data are collected/recorded, or calculated, in thi...
ASTM D7458-21 is classified under the following ICS (International Classification for Standards) categories: 13.080.10 - Chemical characteristics of soils. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM D7458-21 has the following relationships with other standards: It is inter standard links to ASTM D4753-24, ASTM D3740-23, ASTM D1356-20a, ASTM D1356-20, ASTM D3740-19, ASTM D4840-99(2018)e1, ASTM E882-10(2016), ASTM E882-10(2016)e1, ASTM D1356-15a, ASTM D1356-15, ASTM D4753-15, ASTM D1356-14b, ASTM D653-14, ASTM D1356-14a, ASTM E177-14. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM D7458-21 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:D7458 −21
Standard Test Method for
Determination of Beryllium in Soil and Sediment Using
Ammonium Bifluoride Extraction and Fluorescence
Detection
This standard is issued under the fixed designation D7458; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.7.1 For purposes of comparing a measured or calculated
value(s) with specified limits, the measured or calculated
1.1 Thistestmethodisintendedforuseinthedetermination
value(s) shall be rounded to the nearest decimal of significant
of beryllium in samples of soil and sediment.This test method
digits in the specified limit.
can be used for purposes such as environmental remediation
1.7.2 Theproceduresusedtospecifyhowdataarecollected/
projectswhereberylliumisacontaminantofconcern.Itisalso
recorded, or calculated, in this standard are regarded as the
usefulforcharacterizationoflevelsofberylliuminsoilatsites
industry standard. In addition, they are representative of the
where beryllium is in mining or manufacturing applications,
significant digits that generally should be retained. The proce-
and for determination of background levels of beryllium in
dures used do not consider material variation, purpose for
soil.
obtaining the data, special purpose studies, or any consider-
1.2 This test method assumes that samples of soil or
ations for the user’s objectives; and it is common practice to
sediment are collected using appropriate and applicable meth-
increase or reduce significant digits of reported data to be
ods.
commensuratewiththeseconsiderations.Itisbeyondthescope
of this standard to consider significant digits used in analytical
1.3 This test method includes a procedure for extraction
(dissolution) of beryllium in dilute ammonium bifluoride, methods for engineering data.
followed by analysis of aliquots of the extract solution using a
1.8 This standard does not purport to address all of the
beryllium-specific fluorescent dye.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
1.4 For a 500 mg sample, the lower limit of the working
priate safety, health, and environmental practices and deter-
range is approximately 0.04 mg Be/kg (5× dilution) or 0.1 mg
mine the applicability of regulatory limitations prior to use.
Be/kg (20× dilution). The working range extends to concen-
1.9 This international standard was developed in accor-
trations of at least 500 mg Be/kg.
dance with internationally recognized principles on standard-
1.5 No detailed operating instructions are provided because
ization established in the Decision on Principles for the
of differences among various makes and models of suitable
Development of International Standards, Guides and Recom-
fluorometric instruments. Instead, the analyst shall follow the
mendations issued by the World Trade Organization Technical
instructions provided by the manufacturer of the particular
Barriers to Trade (TBT) Committee.
instrument. This test method does not address comparative
accuracy of different devices or the precision between instru-
2. Referenced Documents
ments of the same make and model.
2.1 ASTM Standards:
1.6 The values stated in SI units are to be regarded as
D653Terminology Relating to Soil, Rock, and Contained
standard. No other units of measurement are included in this
Fluids
standard.
D1193Specification for Reagent Water
1.7 All observed and calculated values shall conform to the D1356Terminology Relating to Sampling and Analysis of
guidelines for significant digits and rounding established in Atmospheres
Practice D6026. D3740Practice for Minimum Requirements for Agencies
Engaged in Testing and/or Inspection of Soil and Rock as
This test method is under the jurisdiction of ASTM Committee D22 on Air
Quality and is the direct responsibility of Subcommittee D22.04 on WorkplaceAir
Quality. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Sept. 1, 2021. Published April 2022. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2008. Last previous edition approved in 2014 as D7458–14. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/D7458-21. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D7458−21
Used in Engineering Design and Construction to potentially affected workers (1, 2). Measurement of beryl-
D4753Guide for Evaluating, Selecting, and Specifying Bal- lium in matrices such as soil and sediment is important in
ances and Standard Masses for Use in Soil, Rock, and environmental remediation projects involving beryllium con-
Construction Materials Testing tamination (3) and for establishment of background levels of
D4840Guide for Sample Chain-of-Custody Procedures beryllium at sites where anthropogenic beryllium may have
D5730Guide for Site Characterization for Environmental been used (2, 4-6). Sampling and analytical methods for
Purposes With Emphasis on Soil, Rock, the Vadose Zone berylliumareneededinordertomeetthechallengesrelatingto
and Groundwater (Withdrawn 2013) exposureassessmentandriskreduction.Samplingandanalysis
D6026Practice for Using Significant Digits and Data Re- methods, such as the procedure described in this test method,
cords in Geotechnical Data aredesiredinordertofacilitatemeasurementsofberylliumthat
D7202Test Method for Determination of Beryllium in the can be used as a basis for management of remediation projects
WorkplacebyExtractionandOpticalFluorescenceDetec- and protection of human health.
tion
5.2 This test method can be used for purposes such as
E177Practice for Use of the Terms Precision and Bias in
environmental remediation projects where beryllium is a con-
ASTM Test Methods
taminant of concern. It is also useful for characterization of
E691Practice for Conducting an Interlaboratory Study to
levelsofberylliuminsoilatsiteswhereberylliumisinmining
Determine the Precision of a Test Method
or manufacturing applications, and for determination of back-
E882Guide for Accountability and Quality Control in the
ground levels of beryllium in soil.
Chemical Analysis Laboratory
5.3 The limit of quantification of this test method varies
2.2 Other Standards:
with the dilution factor (see 13.6.1). For the detection solution
ISO594-2Conical Fittings with a 6% (Luer) Taper for
containing lysine the detection limit is 0.013mg beryllium per
Syringes, Needles and Certain Other Medical
kilogram of sample, based on a 0.5g sample (7) extracted in a
Equipment—Part 2: Lock Fittings
50 mLextraction solution and analyzed using a dilution factor
EN ISO 8655-2Piston-Operated Volumetric Pipettes—Part
of 20×. When the lysine-free detection solution is used one
2: Piston Pipettes
may use a 20× dilution factor and obtain the same detection
limit or use 5× dilution factor and obtain a detection limit of
3. Terminology
0.004 mg/kg of sample.
3.1 Definitions—For definitions of common technical terms
NOTE 1—Users of this standard are cautioned that compliance with
used in this standard, refer to Terminology D653 and D1356.
Practice D3740 does not in itself assure reliable results. Reliable results
depend on many factors; Practice D3740 provides a means of evaluating
some of those factors.
4. Summary of Test Method
4.1 This standard test method is used to determine the
6. Interferences
beryllium content of soil or sediment. Samples are collected in
6.1 This test method is specific for beryllium. Other sol-
the field using appropriate and applicable procedures, for
vated metal ions are either bound by ethylenediaminetet-
example,thosedescribedinASTMInternationalstandards;see
raacetic acid (EDTA) in the detection solution, or they precipi-
Guide D5730 for listings of appropriate sample collection
tateoutduetothehighalkalinityofthedetectionsolution.The
standards. A 0.5 g aliquot is extracted using 3% ammonium
fluorophore used for detection is specific for the beryllium
bifluoride solution heated at 90°C for 40 hours. The presence
+2
divalent cation (Be ).
of active fluoride ions (HF by dissociation of ammonium
bifluoride in acidic medium) enables dissolution of refractory
6.2 If iron or titanium are present in high excess in the
forms of beryllium, including silicates, borosilicates, and
sample (typically above 7%), the resulting measurement
oxides. The extraction solution produced from each sample is
solution may appear golden-yellow. In this case the solution is
then filtered and an aliquot of this extract is added to a
left for two hours or more for the iron or titanium (or both) to
pH-adjusted detection solution which contains a beryllium-
precipitate. The solution is then re-filtered using the same
specific fluorescence reagent. The fluorescence of this final
procedure as for filtering the extraction solution (after the
solution is then measured on a calibrated fluorometer to
dissolution step), prior to fluorescence measurement.
quantify the amount of beryllium in the sample. This standard
test method is adapted from Test Method D7202. 7. Apparatus
7.1 Sampling Equipment—Use sampling apparatus appro-
5. Significance and Use
priate for the type of media being collected (for example, soil,
5.1 Exposure to beryllium can cause a potentially fatal
rock, sediment, fly ash) and its location (for example, surface,
disease, and occupational exposure limits for beryllium in air
subsurface,vadosezone).Guidanceonselectionofappropriate
andonsurfaceshavebeenestablishedtoreduceexposurerisks
sampling apparatus can be found as referenced in Guide
D5730.
The last approved version of this historical standard is referenced on
www.astm.org.
4 5
Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St., The boldface numbers in parentheses refer to a list of references at the end of
4th Floor, New York, NY 10036, http://www.ansi.org. this standard.
D7458−21
7.2 Ultraviolet/Visible (UV/Vis) Fluorometer—A device 8.2 Purity of Water—Unless otherwise indicated, references
with irradiance excitation lamp or light-emitting diode (exci- to water shall be understood to mean reagent as defined by
tationλ=365 or 384 nm) and time-integrating visible detector TypeIofSpecificationD1193(ASTMTypeIWater:minimum
(400–700 nm, λmax ≈ 475 nm). resistance of 18 MΩ-cm or equivalent).
7.3 Balance—Balances shall conform to Guide D4753 and
8.3 Calibration Stock Solution—1000 ppm beryllium in
shall have a readability without estimation of 0.1 mg.
dilute nitric acid.
7.4 Oven—Vented,thermostaticallycontrolledovencapable
8.4 Ethylenediaminetetraacetic acid (EDTA) disodium salt
of maintaining a uniform temperature of 90°C 6 2°C
dihydrate.
throughout the drying chamber.
8.5 L-lysine monohydrochloride.
7.5 Centrifuge Tubes—Plastic tubes with a capacity of
8.6 10-hydroxybenzo[h]quinoline-7-sulfonate (10-HBQS).
15mL and if needed, 50mL.
7.6 Polypropylene Bottles—Bottles with screw caps having 8.7 Sodium hydroxide (NaOH).
a capacity between 60mL to 100 mL.
8.8 Extraction (or Dissolution) Solution—Mass fraction
7.7 Syringe Filters—Hydrophilic polypropylene or
3% ammonium bifluoride (NH HF ) solution (aqueous) for
4 2
polyethersulfone filters in plastic housings with a pore size of
dissolution of beryllium in collected specimens. The solution
0.2 to 0.45 µm and having a diameter of 13mm or 25mm. A
may be prepared by dissolving 30g 6 0.3 g of solid NH HF
4 2
0.2 µm pore size filter is preferred.
in Type 1 water to a total volume of 1000 mL. Warning—
Ammonium bifluoride will etch glass, so it is necessary that
7.8 Syringes—Plastic syringes with a capacity of 5mL or
NH HF solutions be contained in plastic labware.
10mL.
4 2
7.9 Pipetters—Mechanical pipetters in an assortment of
8.9 Detection Solution—63.4 µM 10-hydroxybenzo[h]
sizes as needed, with tolerances in accordance with EN ISO quinoline-7-sulfonate (10-HBQS) (8, 9) / 2.5 mM ethylenedi-
8655-2.
aminetetraacetic acid (EDTA)/50.8 mM lysine monohydro-
chloride (pH adjusted to 12.8 with NaOH): The aqueous
7.10 Pipet Tips—Disposable plastic pipet tips in an assort-
detection reagent is prepared by the addition of 12.5 mLof 2.5
ment of sizes sizes as needed, with tolerances in accordance
mM ethylenediaminetetraacetic acid (EDTA) disodium salt
with EN ISO 8655-2.
dihydrate and 25 mL of 107 mM L-lysine monohydrochloride
7.11 Fluorescence Cuvettes—Disposable, low fluorescence,
to 3 mL of 1.1 mM 10-hydroxybenzo[h]quinoline-7-sulfonate
10mm path length, transparent to UV/Visible radiation cu-
(10-HBQS). The pH is adjusted to 12.85 with addition of
vettes.
sodium hydroxide andType 1 water added to a total of 50 mL.
7.12 Thermometric Device—Athermometricdevicecapable
8.9.1 An alternative preparation of dye solution without
of measuring the temperature range within which the test is
lysinemaybemadebyadding1.104gofEDTAand64µmoles
being performed readable to 0.5°C or better and having an
of the 10-HBQS dye in 900 mLof water.After a clear solution
accuracy of at least 60.5°C.
is obtained, 114.5 mL of 2.5 M NaOH is added and mixed to
obtain the final dye solution.
7.13 Miscellaneous Items—The following items may be
needed: plastic beakers, plastic flasks, plastic graduated 8.9.1.1 Check the pH of the dye solution by using the pH
cylinders, plastic or plastic coated forceps, microfilters, meter; the measured pH should be 12.5 to 13.3. If the pH
requiresadjustmenttofallwithinthedesiredpHrange,add2.5
respirators, masks, gloves, lab coats, safety eyewear.
M NaOH dropwise until the measured pH is satisfactory.
7.14 pH Meter—FormeasurementofpHtowithin 60.1pH
unit. NOTE 2—The pH of the dye solution was measured byAdams et al. (7)
as 13.2. The dye solution without lysine may be used for all analytical
purposes and also provides superior detection limits.
8. Reagents
8.1 Purity of Reagents—Reagent grade chemicals shall be
9. Hazards
used.Unlessotherwiseindicated,itisintendedthatallreagents
conform to the specifications of the Committee on Analytical 9.1 Ammonium bifluoride is highly corrosive, and is very
Reagents of the American Chemical Society where such
toxic when in contact with the skin. Effects to the skin,
specifications are available. Other grades may be used, pro- includingirritationandburns,maynotbefeltforseveralhours.
vided it is first ascertained that the reagent is of sufficiently Avoidexposurebycontactwiththeskin.Usesuitablepersonal
high purity to permit its use without lessening the accuracy of protective equipment (including impermeable gloves and eye
the determination. protection)whenworkingwithNH HF .SeeAppendixX1for
4 2
further pertinent safety information.
9.2 Hydrofluoric acid can cause serious medical issues.
ACS Reagent Chemicals, Specifications and Procedures for Reagents and
Standard-Grade Reference Materials, American Chemical Society, Washington,
Uponcontactwithskin,iteasilyandquicklyentersthroughthe
DC. For suggestions on the testing of reagents not listed by theAmerican Chemical
skin and into the tissues in the body where it damages cells.
Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset,
Upon inhalation, it can damage lung tissue and cause swelling
U.K., and the United States Pharmacopeia and National Formulary, U.S. Pharma-
copeial Convention, Inc. (USPC), Rockville, MD. and fluid buildup in the lungs. The seriousness of chemical
D7458−21
NOTE 3—The specimen size of 0.5 g is typically necessary to suffi-
exposure depends on the amount, route, and length of time of
cientlyaccountfortheheterogeneousnatureofsoilandsedimentsamples
exposure. Use appropriate protective equipment as stated in
(14). In cases where the matrix is sufficiently homogenous to allow a
9.1.
smaller specimen size (for example, 50 mg), the amount of extraction
solution may be reduced (for example, to 5 mL instead of 50 mL).
10. Sampling and Test Specimens
10.1 Sample Collection—Collect samples in accordance 11. Preparation of Apparatus
with applicable standards for the type of media of interest (for
11.1 Fluorometer Set-Up—Set up the fluorometer for exci-
example, soil, rock, sediment, fly ash) and the location being
tation radiation from 360nm to 390 nm (peak wavelengths are
sampled (for example, surface, vadose zone). Refer to Guide
365nm or 384nm) and measurement of emission in a spectral
D5730 in selecting applicable standards for sample collection.
window selected from a range of (at least) 440nm to 490 nm.
10.2 Sample Transport—Ifapplicable(thatis,ifsamplesare Allow appropriate warm-up of the system prior to analysis in
transported to a different location prior to sample preparation accordance with the manufacturer’s instructions.
and analysis), follow sampling chain-of-custody procedures to
NOTE 4—For fluorescence measurement, an emission band pass filter
document sample traceability. Make sure that the documenta-
with peak transmission wavelength at ~475 nm and with a full width at
tion that accompanies the samples is suitable for a chain of
half maximum (FWHM) of less than 620 nm have been shown to be
effective (4, 5).
custody to be established in accordance with Guide D4840.
10.3 Wear appropriate personal protection during sample
12. Calibration
aliquoting, specimen preparation, and analysis activities. Per-
12.1 Preparation of Calibration Standards—Using calibra-
form these activities in a clean area that is well removed from
tion stock solution and detection solution, prepare at least four
possible beryllium contamination.
standards covering the concentration range of interest. Record
10.4 Specimen Preparation—Obtain a 0.5 g specimen (ali-
the concentration of each standard.
quot) that is representative of the sample (10-13) (Note 3).
NOTE 5—For example: To measure from about 1mg to 80 mg of
Measure and record the mass of the specimen to the nearest
beryllium in samples, calibration standards from 0parts per billion (ppb)
0.1mgandputitintoapolypropylenebottle.Closethelidand
to800ppbarerecommended(seeTable1).Alternatively,adifferentrange
of calibration standards, covering the range of interest, may be used
gentlytapthelidtomakesurethatallofthespecimen(aliquot)
provided that a linear calibration curve can be produced.
falls to the bottom of the bottle. The bottle size is typically
10mL to 50mL larger than the liquid to be added. 12.2 Calibration and Specifications:
TABLE 1 Preparation of Calibration Standards
Final Concentration of Corresponding Amount of
Specimen Beryllium (ppb) in Beryllium (Be)
A
Calibration Standard Solutions in Sample (mg/kg)
0.1 mL of 0 ppb standard 0.0 Corresponds to 0 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 10 ppb standard 0.50 Corresponds to 1 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 40 ppb standard 2.0 Corresponds to 4 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 200 ppb standard 10.0 Corresponds to 20 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 800 ppb standard 40.0 Corresponds to 80 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.4 mL of 0 ppb standard 0.0 Corresponds to 0 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF=5) when DF = 5
0.4 mL of 1 ppb standard 0.20 Corresponds to 0.1mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF=5) when DF = 5
0.4 mL of 4 ppb standard 0.80 Corresponds to 0.4 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF=5) when DF = 5
0.4 mL of 20 ppb standard 4.0 Corresponds to 2 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF=5) when DF = 5
0.4 mL of 80 ppb standard 16. Corresponds to 8 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF=5) when DF = 5
A
Incorporating sample dilution factor for 50 mL of extraction solution and 0.5 g of sample; note that volumes other than 50 mL and/or a different sample size will require
a different appropriate dilution factor.
D7458−21
acorrelationbetweenvariousstandards,calibrationstandardsolutionsand
12.2.1 Calibration Blank and Calibration Stock Standard
the amount of beryllium in the sampling medium.
Solutions Preparation—Calibration blank is prepared by add-
ing the 0 ppb standard and the detection solution at a volume
13. Procedure
proportion of 1:19 into a cuvette suitable for fluorescence
13.1 Remove the lid of the polypropylene bottle containing
measurements. Calibration standard solutions are also made in
the specimen (aliquot). Use a graduated cylinder to measure
a similar fashion where the calibration standard and the
50mL 6 0.5 mL of extraction solution and then add it to the
detectorsolutionaremixedinavolumetricratioof1:19(a20×
bottle.
dilution) and in a volumetric ratio of 1:4 in case 5× dilution is
used. At least four standard measurement solutions, plus a
13.2 Put the lid back on tightly and swirl the bottle to make
blank, must be made for calibration. Make sure that these are sure that the specimen is completely wetted.
mixed fully.
13.3 Preheat a laboratory oven to 90°C 6 2°C. Place the
12.2.2 For routine beryllium analyses, calibration stock
bottle in the oven for 40h 61h.
standard solution concentrations of 0ppb, 10ppb, 40ppb,
NOTE 10—The 40-hour heating
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7458 − 14 D7458 − 21
Standard Test Method for
Determination of Beryllium in Soil, Rock, Sediment, and Fly
Ash Soil and Sediment Using Ammonium Bifluoride
Extraction and Fluorescence Detection
This standard is issued under the fixed designation D7458; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*Scope
1.1 This test method is intended for use in the determination of beryllium in samples of soil, rock, sediment, and fly ash. soil and
sediment. This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant
of concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing
applications, and for determination of background levels of beryllium in soil.
1.2 This test method assumes that samples of soil, rock, sediment, or fly ash soil or sediment are collected using appropriate and
applicable ASTM International standard practices.methods.
1.3 This test method includes a procedure for extraction (dissolution) of beryllium in dilute ammonium bifluoride, followed by
analysis of aliquots of the extract solution using a beryllium-specific fluorescent dye.
1.4 For a 500 mg sample, the lower limit of the working range is approximately 0.04 mg Be/kg (5× dilution) or 0.1 mg Be/kg
(20× dilution). The working range extends to concentrations of at least 500 mg Be/kg.
1.5 No detailed operating instructions are provided because of differences among various makes and models of suitable
fluorometric instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular
instrument. This test method does not address comparative accuracy of different devices or the precision between instruments of
the same make and model.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice
D6026.
1.7.1 For purposes of comparing a measured or calculated value(s) with specified limits, the measured or calculated value(s) shall
be rounded to the nearest decimal of significant digits in the specified limit.
1.7.2 The procedures used to specify how data are collected/recorded, or calculated, in this standard are regarded as the industry
standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not
This test method is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.
Current edition approved May 1, 2014Sept. 1, 2021. Published June 2014April 2022. Originally approved in 2008. Last previous edition approved in 20082014 as
D7458 – 08.D7458 – 14. DOI: 10.1520/D7458-14.10.1520/D7458-21.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D7458 − 21
consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives;
and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations.
It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design.data.
1.7 This test method contains notes that are explanatory and not part of mandatory requirements of the standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.Specific hazards associated with performance of this test method are described
in Section 9.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2.1 ASTM Standards:
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D1193 Specification for Reagent Water
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in
Engineering Design and Construction
D4753 Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction
Materials Testing
D4840 Guide for Sample Chain-of-Custody Procedures
D5730 Guide for Site Characterization for Environmental Purposes With Emphasis on Soil, Rock, the Vadose Zone and
Groundwater (Withdrawn 2013)
D6026 Practice for Using Significant Digits and Data Records in Geotechnical Data
D7202 Test Method for Determination of Beryllium in the Workplace by Extraction and Optical Fluorescence Detection
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E882 Guide for Accountability and Quality Control in the Chemical Analysis Laboratory
2.2 Other Standards:
ISO 594-2 Conical Fittings with a 6 % (Luer) Taper for Syringes, Needles and Certain Other Medical Equipment—Part 2: Lock
Fittings
EN ISO 8655-2 Piston-Operated Volumetric Pipettes—Part 2: Piston Pipettes
3. Terminology
3.1 Definitions—For definitions of common technical terms used in this standard, see refer to Terminology D653 and D1356.
4. Summary of Test Method
4.1 This standard test method is used to determine the beryllium content of soil, rock, sediment, and fly ash. soil or sediment.
Samples are collected in the field using procedures appropriate and applicable procedures, for example, those described in ASTM
International standards (seestandards; see Guide D5730 for listings of appropriate sample collection standards).standards. A
0.5-gram 0.5 g aliquot is extracted using 3 % ammonium bifluoride solution heated at 90°C90 °C for 40 hours. The presence of
active fluoride ions (HF by dissociation of ammonium bifluoride in acidic medium) enables dissolution of refractory forms of
beryllium, including silicates, borosilicates, and oxides. The extraction solution produced from each sample is then filtered and an
aliquot of this extract is added to a pH-adjusted detection solution which contains a beryllium-specific fluorescence reagent. The
fluorescence of this final solution is then measured on a calibrated fluorometer to quantify the amount of beryllium in the sample.
This standard test method is adapted from Test Method D7202.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
The last approved version of this historical standard is referenced on www.astm.org.
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
D7458 − 21
4.2 The limit of quantification of this test method is 0.013 milligrams beryllium per kilogram of sample, based on a 0.5-gram
sample (1).
5. Significance and Use
5.1 Exposure to beryllium can cause a potentially fatal disease, and occupational exposure limits for beryllium in air and on
surfaces have been established to reduce exposure risks to potentially affected workers (21, 32). Measurement of beryllium in
matrices such as soil, rock, sediment, and fly ash soil and sediment is important in environmental remediation projects involving
beryllium contamination (43) and for establishment of background levels of beryllium at sites where anthropogenic beryllium may
have been used (2, 4-6). Sampling and analytical methods for beryllium are needed in order to meet the challenges relating to
exposure assessment and risk reduction. Sampling and analysis methods, such as the procedure described in this test method, are
desired in order to facilitate measurements of beryllium that can be used as a basis for management of remediation projects and
protection of human health.
5.2 This test method can be used for purposes such as environmental remediation projects where beryllium is a contaminant of
concern. It is also useful for characterization of levels of beryllium in soil at sites where beryllium is in mining or manufacturing
applications, and for determination of background levels of beryllium in soil.
5.3 The limit of quantification of this test method varies with the dilution factor (see 13.6.1). For the detection solution containing
lysine the detection limit is 0.013 mg beryllium per kilogram of sample, based on a 0.5 g sample (7) extracted in a 50 mL extraction
solution and analyzed using a dilution factor of 20×. When the lysine-free detection solution is used one may use a 20× dilution
factor and obtain the same detection limit or use 5× dilution factor and obtain a detection limit of 0.004 mg/kg of sample.
NOTE 1—The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the
equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing,
sampling, inspection, and so forth. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results.
Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
6. Interferences
6.1 This test method is highly specific for beryllium. Other solvated metal ions are either bound by ethylenediaminetetraacetic acid
(EDTA) in the detection solution, or they precipitate out due to the high alkalinity of the detection solution. The fluorophore used
+2
for detection is highly specific for the beryllium divalent cation (Be ).
6.2 If iron or titanium are present in high excess in the sample (typically above 7 %), the resulting measurement solution may
appear golden-yellow. In this case the solution is left for two hours or more for the iron or titanium (or both) to precipitate. The
solution is then re-filtered using the same procedure as for filtering the dissolutionextraction solution (after the dissolution step),
prior to fluorescence measurement.
7. Apparatus
7.1 Sampling Equipment—Use sampling apparatus appropriate for the type of media being collected (for example, soil, rock,
sediment, fly ash) and its location (for example, surface, subsurface, vadose zone). Guidance on selection of appropriate sampling
apparatus is found in the ASTM International standards can be found as referenced in Guide D5730.
7.2 Instrumentation: Ultraviolet/Visible (UV/Vis) Fluorometer—
7.2.1 Ultraviolet/Visible (UV/Vis) Fluorometer, with irradiance excitation lamp or light-emitting diode (excitation λ = 380 nm) and
time-integrating visible detector (400–700 nm, λmax ≈ 475 nm).A device with irradiance excitation lamp or light-emitting diode
(excitation λ = 365 or 384 nm) and time-integrating visible detector (400–700 nm, λmax ≈ 475 nm).
7.2.2 Laboratory Balance, capable of measuring to the nearest 0.1 mg.
7.2.3 Laboratory Oven, capable of maintaining a temperature of 90 6 2°C.
The boldface numbers in parentheses refer to thea list of references at the end of this standard.
D7458 − 21
7.3 Balance—Balances shall conform to Guide D4753 and shall have a readability without estimation of 0.1 mg.
7.4 Oven—Vented, thermostatically controlled oven capable of maintaining a uniform temperature of 90 °C 6 2 °C throughout the
drying chamber.
7.5 Centrifuge Tubes—Plastic tubes with a capacity of 15 mL and if needed, 50 mL.
7.6 Polypropylene Bottles—Bottles with screw caps having a capacity between 60 mL to 100 mL.
7.7 Syringe Filters—Hydrophilic polypropylene or polyethersulfone filters in plastic housings with a pore size of 0.2 to 0.45 μm
and having a diameter of 13 mm or 25 mm. A 0.2 μm pore size filter is preferred.
7.8 Syringes—Plastic syringes with a capacity of 5 mL or 10 mL.
7.9 Pipetters—Mechanical pipetters in an assortment of sizes as needed, with tolerances in accordance with EN ISO 8655-2.
7.10 Laboratory Supplies: Pipet Tips—
7.3.1 Centrifuge Tubes, plastic, 15-mL (plus 50-mL, if necessary).Disposable plastic pipet tips in an assortment of sizes sizes as
needed, with tolerances in accordance with EN ISO 8655-2.
7.3.2 Polypropylene Bottles, 60 to 100 mL, with screw caps.
7.3.3 Syringe Filters, 0.45-μm or smaller pore size filters, for example, 13 or 25-mm diameter nylon filters, in plastic housings.
7.3.4 Syringes, plastic, 5-mL or 10-mL.
7.3.5 Pipetters, mechanical, of assorted sizes as needed, with tolerances in accordance with EN ISO 8655-2.
7.3.6 Pipet Tips, plastic, disposable, of assorted sizes as needed, with tolerances in accordance with EN ISO 8655-2.
7.3.7 Fluorescence Cuvettes, disposable, low fluorescence, 10-mm path length, transparent to UV/Visible radiation.
7.3.8 Labware, plastic (for example, beakers, flasks, graduated cylinders, and so forth), of assorted sizes as needed.
7.3.9 Forceps, plastic or plastic-coated.
7.3.10 Personal Protective Wear, for example, respirators, masks, gloves, lab coats, safety eyewear, and so forth, as needed.
7.3.11 Thermometer, to at least 100°C (accuracy 6 1°C).
7.3.12 Other general laboratory supplies as needed.
7.11 Fluorescence Cuvettes—Disposable, low fluorescence, 10 mm path length, transparent to UV/Visible radiation cuvettes.
7.12 Thermometric Device—A thermometric device capable of measuring the temperature range within which the test is being
performed readable to 0.5 °C or better and having an accuracy of at least 60.5 °C.
7.13 Miscellaneous Items—The following items may be needed: plastic beakers, plastic flasks, plastic graduated cylinders, plastic
or plastic coated forceps, microfilters, respirators, masks, gloves, lab coats, safety eyewear.
7.14 pH Meter—For measurement of pH to within 60.1 pH unit.
D7458 − 21
8. Reagents
8.1 Purity of Reagents—Reagent grade chemicals shall be used. Unless otherwise indicated, it is intended that all reagents conform
to the specifications of the Committee on Analytical Reagents of the American Chemical Society where such specifications are
available. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use
without lessening the accuracy of the determination.
8.2 Purity of Water—Unless otherwise indicated, references to water shall be understood to mean reagent as defined by Type I of
Specification D1193 (ASTM Type I Water: minimum resistance of 18 MΩ-cm or equivalent).
8.3 Calibration Stock Solution—1000 ppm beryllium in dilute nitric acid.
8.4 Ethylenediaminetetraacetic acid (EDTA) disodium salt dihydrate.
8.5 L-lysine monohydrochloride.
8.6 10-hydroxybenzo[h]quinoline-7-sulfonate (10-HBQS).
8.7 Sodium hydroxide (NaOH).
8.8 Extraction (or Dissolution) Solution—Mass fraction 3 % ammonium bifluoride (NH HF ) solution (aqueous) for dissolution
4 2
of beryllium in collected particulate matter. specimens. The solution may be prepared by dissolving 3030 g 6 0.3 g of solid
NH HF in Type 1 water to a total volume of 1000 mL. (Warning—Ammonium bifluoride will etch glass, so it is
4 2
essentialnecessary that all NH HF solutions be contained in plastic labware.)
4 2
8.9 Detection Solution—63.4 μM 10-hydroxybenzo[h] quinoline-7-sulfonate (10-HBQS) (58, 9) / 2.5 mM ethylenediaminetet-
raacetic acid (EDTA)/50.8 mM lysine monohydrochloride (pH adjusted to 12.8 with NaOH): The aqueous detection reagent is
prepared by the addition of 12.5 mL of 2.5 mM ethylenediaminetetraacetic acid (EDTA) disodium salt dihydrate and 25 mL of 107
mM L-lysine monohydrochloride to 3 mL of 1.1 mM 10-hydroxybenzo[h]quinoline-7-sulfonate (10-HBQS). The pH is adjusted
to 12.85 with addition of sodium hydroxide and Type 1 water added to a total of 50 mL.
8.9.1 An alternative preparation of dye solution without lysine may be made by adding 1.104 g of EDTA and 64 μmoles of the
10-HBQS dye in 900 mL of water. After a clear solution is obtained, 114.5 mL of 2.5 M NaOH is added and mixed to obtain the
final dye solution.
8.9.1.1 Check the pH of the dye solution by using the pH meter; the measured pH should be 12.5 to 13.3. If the pH requires
adjustment to fall within the desired pH range, add 2.5 M NaOH dropwise until the measured pH is satisfactory.
NOTE 2—The pH of the dye solution was measured by Adams et al. (7) as 13.2. The dye solution without lysine may be used for all analytical purposes
and also provides superior detection limits.
9. Hazards
9.1 Ammonium bifluoride is highly corrosive, and is very toxic when in contact with the skin. Effects to the skin, including
irritation and burns, may not be felt for several hours. Avoid exposure by contact with the skin. Use suitable personal protective
equipment (including impermeable gloves and eye protection) when working with NH HF . See Appendix X1 for further pertinent
4 2
safety information.
9.2 Hydrofluoric acid can cause serious medical issues. Upon contact with skin, it easily and quickly enters through the skin and
Supporting data have been filed at ASTM International Headquarters and may beACS Reagent Chemicals, Specifications and Procedures for Reagents and
Standard-Grade Reference Materials, obtained by requesting Research ReportAmerican Chemical Society, Washington, DC. For suggestions on the testing of reagents not
listed by the American Chemical RR:D18-1016.Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia
and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville, MD.
D7458 − 21
into the tissues in the body where it damages cells. Upon inhalation, it can damage lung tissue and cause swelling and fluid buildup
in the lungs. The seriousness of chemical exposure depends on the amount, route, and length of time of exposure. Use appropriate
protective equipment as stated in 9.1.
10. Sample Collection and Transport
10.1 Sample Collection—Collect samples in accordance with applicable ASTM International standards for the type of media (for
example, soil, rock, sediment, fly ash) and the location being sampled (for example, surface, vadose zone). Refer to Guide D5730
in selecting applicable ASTM International standards for sample collection.
10.2 Sample Transport—If applicable (that is, if samples are transported to a different location prior to sample preparation and
analysis), follow sampling chain-of-custody procedures to document sample traceability. Make sure that the documentation that
accompanies the samples is suitable for a chain of custody to be established in accordance with Guide D4840.
10. Sampling and Test Specimens
10.1 Sample Collection—Collect samples in accordance with applicable standards for the type of media of interest (for example,
soil, rock, sediment, fly ash) and the location being sampled (for example, surface, vadose zone). Refer to Guide D5730 in selecting
applicable standards for sample collection.
10.2 Sample Transport—If applicable (that is, if samples are transported to a different location prior to sample preparation and
analysis), follow sampling chain-of-custody procedures to document sample traceability. Make sure that the documentation that
accompanies the samples is suitable for a chain of custody to be established in accordance with Guide D4840.
10.3 Wear appropriate personal protection during sample aliquoting, specimen preparation, and analysis activities. Perform these
activities in a clean area that is well removed from possible beryllium contamination.
10.4 Specimen Preparation—Obtain a 0.5 g specimen (aliquot) that is representative of the sample (10-13) (Note 3). Measure and
record the mass of the specimen to the nearest 0.1 mg and put it into a polypropylene bottle. Close the lid and gently tap the lid
to make sure that all of the specimen (aliquot) falls to the bottom of the bottle. The bottle size is typically 10 mL to 50 mL larger
than the liquid to be added.
NOTE 3—The specimen size of 0.5 g is typically necessary to sufficiently account for the heterogeneous nature of soil and sediment samples (14). In cases
where the matrix is sufficiently homogenous to allow a smaller specimen size (for example, 50 mg), the amount of extraction solution may be reduced
(for example, to 5 mL instead of 50 mL).
11. Preparation of Apparatus
11.1 Fluorometer Set-Up—Set up the fluorometer for excitation radiation from 360 nm to 390 nm (peak wavelengths are 365 nm
or 384 nm) and measurement of emission in a spectral window selected from a range of (at least) 440 nm to 490 nm. Allow
appropriate warm-up of the system prior to analysis in accordance with the manufacturer’s instructions.
NOTE 4—For fluorescence measurement, an emission band pass filter with peak transmission wavelength at ~475 nm and with a full width at half
maximum (FWHM) of less than 620 nm have been shown to be effective (4, 5).
12. Calibration
12.1 Preparation of Calibration Standards—Using calibration stock solution and detection solution, prepare at least four standards
covering the concentration range of interest. Record the concentration of each standard.
NOTE 5—For example: To measure from about 1 mg to 80 mg of beryllium in samples, calibration standards from 0 parts per billion (ppb) to 800 ppb
are recommended (see Table 1). Alternatively, a different range of calibration standards, covering the range of interest, may be used provided that a linear
calibration curve can be produced.
12.2 Calibration and Specifications:
12.2.1 Calibration Blank and Calibration Stock Standard Solutions Preparation—Calibration blank is prepared by adding the 0
D7458 − 21
TABLE 1 Preparation of Calibration Standards (Example)
Concentration ofSpecimen Final Concentration of Corresponding Amount of
Beryllium Used in Beryllium (ppb) in Beryllium (Be)
A
Calibration Standards Calibration Standard Solutions in Sample (mg/kg)
0.1 mL of 0 ppb standard 0.0 Corresponds to 0 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 10 ppb standard 0.50 Corresponds to 1 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 40 ppb standard 2.0 Corresponds to 4 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 200 ppb standard 10.0 Corresponds to 20 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.1 mL of 800 ppb standard 40.0 Corresponds to 80 mg/kg
+ 1.9 mL of detection solution beryllium per sample
(DF = 20) when DF = 20
0.4 mL of 0 ppb standard 0.0 Corresponds to 0 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF = 5) when DF = 5
0.4 mL of 1 ppb standard 0.20 Corresponds to 0.1mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF = 5) when DF = 5
0.4 mL of 4 ppb standard 0.80 Corresponds to 0.4 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF = 5) when DF = 5
0.4 mL of 20 ppb standard 4.0 Corresponds to 2 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF = 5) when DF = 5
0.4 mL of 80 ppb standard 16. Corresponds to 8 mg/kg
+ 1.6 mL of detection solution beryllium per sample
(DF = 5) when DF = 5
A
Incorporating sample dilution factor for 50 mL of dissolutionextraction solution and 0.5 g of sample; note that volumes other than 50 mL and/or a different sample size
will require a different appropriate dilution factor.
ppb standard and the detection solution at a volume proportion of 1:19 into a cuvette suitable for fluorescence measurements.
Calibration standard solutions are also made in a similar fashion where the calibration standard and the detector solution are mixed
in a volumetric ratio of 1:19 (a 20× dilution) and in a volumetric ratio of 1:4 in case 5× dilution is used. At least four standard
measurement solutions, plus a blank, must be made for calibration. Make sure that these are mixed fully.
12.2.2 For routine beryllium analyses, calibration stock standard solution concentrations of 0 ppb, 10 ppb, 40 ppb, 200 ppb and
800 ppb are used. When lower detection limits are necessary, concentrations of 0 ppb, 1 ppb, 4 ppb, 20 ppb, and 80 ppb are
recommended; see Table 1 for an example.
NOTE 6—The 0 ppb, 1 ppb, 4 ppb, 20 ppb, and 80 ppb standards may be made by diluting the 0 ppb, 10 ppb, 40 ppb, 200 ppb, and 800 ppb standards in
3 % ammonium bifluoride extraction solution, for example taking 0.1 mL of 800 ppb standard and mixing it with 0.9 mL of 3 % ammonium bifluoride
will result in a standard with 80 ppb beryllium. Concentrations may be adjusted based on anticipated beryllium content. Solutions are preferably made
up in 3 % ammonium bifluoride; alternatively, commercially available solutions using 1 % ammonium bifluoride may be used. Use of either 1 % or 3 %
ammonium bifluoride has been determined to be acceptable (5).
12.2.3 Instrument Calibration:
12.2.3.1 Using the calibration standard solutions prepared above, calibrate the instrument for fluorescence intensity versus the
concentration of beryllium. A calibration curve using linear regression shall be obtained between the fluorescent intensity and the
concentration of beryllium. Samples shall not be left in the instrument for longer than necessary for measurement (see Note 7).
The instrument should be programmed to display the concentrations (in ppb) of the calibration solutions. The correlation coefficient
should be equal or greater than 0.999.
NOTE 7—Leaving samples in the instrument for longer than necessary can cause changes in sample temperature and consequent change in signal intensity.
12.2.3.2 Verify calibration by measuring an intermediate concentration standard, which should yield a value of within 10 % of the
known value. The calibration shall be verified at least once every two hours (for example, after completing the measurement of
the unknowns) to make sure that calibration still holds (Note 8).
D7458 − 21
NOTE 8—Changes in temperature can cause a drift in the readings; thus, it is important to verify calibration periodically.
12.2.4 The calibration of fluorescence intensity due to the amount of beryllium present can be accomplished in either of two ways:
by examining instrument response due to (a) the concentration of beryllium in calibration solutions, or (b) in terms of the amount
of beryllium in the media; see Table 1.
NOTE 9—The intensity calibration on the instrument may have been carried out in terms of absolute intensity or one of the following if the instrument
automatically prepared a correlation using linear regression fit of concentration of beryllium in calibration standards, concentration of beryllium in
calibration standard solutions or in terms of amount of beryllium in the medium (soil, rock, sediment, or fly ash). Table 1 shows a correlation between
various standards, calibration standard solutions and the amount of beryllium in the sampling medium.
13. Procedure
13.1 Remove the lid of the polypropylene bottle containing the specimen (aliquot). Use a graduated cylinder to measure 50 mL
6 0.5 mL of extraction solution and then add it to the bottle.
13.2 Put the lid back on tightly and swirl the bottle to make sure that the specimen is completely wetted.
13.3 Preheat a laboratory oven to 90 °C 6 2 °C. Place the bottle in the oven for 40 h 6 1 h.
NOTE 10—The 40-hour heating step may be reduced by using a more concentrated solution: up to mass fraction 10 % of NH HF can be used. After
4 2
extraction using concentrations at or above mass fraction 5 % NH HF , dilution with water is necessary to maintain a pH of 12 or higher when mixed
4 2
with the dye solution; this pH is necessary to achieve quantitative recovery (7, 8). Method evaluation by using more concentrated NH HF should consider
4 2
the sample media, particle physical characteristics (such as shape and size) and the inertness of beryllium-containing compounds in the specimens being
analyzed.
13.4 Remove the bottle from the oven and allow it to cool to ambient temperature.
13.5 Filtration—It is not necessary to filter all of the specimen and extraction solution since each analysis only needs 0.1 mL of
solution. Therefore, to filter the solution, attach a 25 mm diameter syringe filter to a 5 mL or 10 mL syringe with a lock fitting
(as described in ISO 594-2) and pour a small amount of approximately 5 mL of the solution into the syringe. Force the solution
through the syringe filter over an inert microfilter into a 15 mL centrifuge tube (see Note 11).
NOTE 11—The filtration process given in 13.5 is one way of filtering the solution. Other methods can be used provided they meet the intended results
of the filtration process given in this standard.
13.6 Specimen Preparation—Preparation of Measurement Solution: Wear appropriate personal protection during specimen
preparation and analysis activities. Perform specimen preparation and analysis in a clean area that is well removed from any
possible beryllium contamination.
13.6.1 Digestion of Samples: Pipet 100 μL of the filtered solution into a fluorescence cuvettes. Add by pipetting 1.9 mL of
detection (dye) solution to the cuvette and make sure these are mixed well by vigorous shaking. This proportion of detection
solution to filtered solution represents a 20× dilution factor (DF). E
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...