17.240 - Radiation measurements
Radiation measurements
Strahlungsmessungen
Mesurage des rayonnements
Merjenje sevanja
General Information
This standard describes the requirements for rapid testing of water samples under emergency situations in laboratories:
- taking into account a special context for analyses, e.g. an unknown and unusual contamination;
- using or adapting if possible radioactivity measurements methods used in routine to get a result
rapidly or applying specific rapid methods previously tested by the laboratory, e.g. for 89Sr determination ;
- preparing the laboratory to analyse a large number of potentially co...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft25 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a method for the measurement of 210Po in all types of waters by alpha spectrometry.
The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample may be required.
The detection limit depends on the sample volume, the instrument used, the count...view more
- Standard28 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft24 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61228:2020 is available as IEC 61228:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61228:2020 describes the method of measuring, evaluating and specifying the UV irradiation characteristics of fluorescent ultraviolet lamps that are used in appliances for tanning purposes. It includes specific requirements regarding the marking of such lamps. This third edition cancels and replaces...view more
- Standard38 pagesEnglish and French language
sale 15% off
2018-12-10: WI started as prA1 on 2010 edition and updated to read prA1 on future 2019 edition (IEC ed 4)
- Amendment20 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non‑negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, the measu...view more
- Standard97 pagesEnglish language
sale 15% off- Standard99 pagesFrench language
sale 15% off- Draft99 pagesFrench language
sale 15% off- Draft97 pagesEnglish language
sale 15% off
This document provides guidelines for testing laboratories wanting to use rapid test methods on water samples that may be contaminated following a nuclear or radiological emergency incident. In an emergency situation, consideration should be given to: — taking into account the specific context for the tests to be performed, e.g. a potentially high level of contamination; — using or adjusting, when possible, radioactivity test methods implemented during routine situations to obtain a result rapid...view more
- Standard20 pagesEnglish language
sale 15% off- Standard22 pagesFrench language
sale 15% off- Draft20 pagesEnglish language
sale 15% off
This document specifies methods and procedures for characterizing the responses of devices used
for the determination of ambient dose equivalent for the evaluation of exposure to cosmic radiation in
civilian aircraft. The methods and procedures are intended to be understood as minimum requirements.
- Standard45 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft43 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a method for the measurement of 210Po in all types of waters by alpha spectrometry. The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample may be required. The detection limit depends on the sample volume, the instrument used, the countin...view more
- Standard19 pagesEnglish language
sale 15% off- Standard20 pagesFrench language
sale 15% off- Draft19 pagesEnglish language
sale 15% off
The primary purpose of this document is to provide minimum acceptable criteria required to establish a procedure for retrospective dosimetry by electron paramagnetic resonance spectroscopy and to report the results. The second purpose is to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories. This document covers the determination of absorbed dose in the measured material. It does not cover the calculation of dose to organs or to the b...view more
- Standard19 pagesEnglish language
sale 15% off- Standard21 pagesFrench language
sale 15% off- Draft19 pagesEnglish language
sale 15% off
The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel. This document covers the determination of absorbed dose in tooth enamel (hydroxyapatite). It does not cover the calculation of dose to organs or to the body. This document ...view more
- Standard22 pagesEnglish language
sale 15% off- Draft22 pagesEnglish language
sale 15% off
This practice covers dosimetric procedures to be followed in installation qualification, operational qualification and performance qualification (IQ, OQ, PQ), and routine processing at electron beam facilities to ensure that the product has been treated with an acceptable range of absorbed doses. Other procedures related to IQ, OQ, PQ, and routine product processing that may influence absorbed dose in the product are also discussed. The electron beam energy range covered in this practice is betw...view more
- Standard13 pagesEnglish language
sale 15% off- Draft13 pagesEnglish language
sale 15% off
This document specifies the characteristics of reference measurement standards of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This document relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV. It does not describe the procedures involved in the use of these reference measurement standards for the calibration of surface contamination monitors. Such...view more
- Standard13 pagesEnglish language
sale 15% off- Standard14 pagesFrench language
sale 15% off- Draft13 pagesEnglish language
sale 15% off
EN-IEC 60580 specifies the performance and testing of DOSE AREA PRODUCT METERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. This document is applicable to the following types of DOSE AREA PRODUCT METERS: a) FIELD-CLASS DOSE AREA PRODUCT METERS normally used for the measurement of DOSE AREA PRODUCTS during MEDICAL RADIOLOGICAL EXAMINATIONS; b) REFERENCE-CLASS DOSE AREA PRODUCT METERS normally used for...view more
- Standard38 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard3 pagesEnglish and French language
sale 15% off
This procedure specifies a method for the determination of 228Ra activity in drinking waters by radium
extraction, purification and liquid scintillation counting.
- Standard37 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft34 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 13164-3:2013 specifies a test method for the determination of radon-222 activity concentration in a sample of water following its transfer from the aqueous phase to the air phase by degassing and its detection. It gives recommendations for rapid measurements performed within less than 1 h.
The radon-222 activity concentrations, which can be measured by this test method utilizing currently available instruments, range from 0,1 Bq l−1 to several hundred thousand becquerels per litre for a 100...view more
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft28 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 13165-2:2014 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by emanometry. The method specified is suitable for the determination of the soluble, suspended, and total 226Ra activity concentration in all types of water with soluble 226Ra activity concentrations greater than 0,02 Bq l−1. In water containing high activity concentrations of 228Th, interference from 220Rn decay products can lead to overestimation of measured levels.
- Standard23 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft20 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 13165-3:2016 specifies the determination of radium-226 (226Ra) activity concentration in all types of water by coprecipitation followed by gamma-spectrometry (see ISO 18589‑3).
The method described is suitable for determination of soluble 226Ra activity concentrations greater than 0,02 Bq l−1 using a sample volume of 1 l to 100 l of any water type.
For water samples smaller than a volume of 1 l, direct gamma-spectrometry can be performed following ISO 10703 with a higher detection limit.
...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft19 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 13164-1:2013 gives general guidelines for sampling, packaging, and transporting of all kinds of water samples, for the measurement of the activity concentration of radon-222.
The test methods fall into two categories: a) direct measurement of the water sample without any transfer of phase (see ISO 13164‑2); b) indirect measurement involving the transfer of the radon-222 from the aqueous phase to another phase (see ISO 13164‑3).
The test methods can be applied either in the laboratory or on...view more
- Standard33 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft30 pagesEnglish language
sale 10% off- e-Library read for1 day