IEC 60336:2020 applies to FOCAL SPOTS in medical diagnostic X-RAY TUBE ASSEMBLIES for medical use, operating at X-RAY TUBE VOLTAGES up to and including 150 kV.
This document describes the test methods employing digital detectors for determining:
a) FOCAL SPOT dimensions in terms of NOMINAL FOCAL SPOT VALUES, ranging from 0,1 to 3,0;
b) LINE SPREAD FUNCTIONS;
c) one-dimensional MODULATION TRANSFER FUNCTIONS;
d) FOCAL SPOT PINHOLE RADIOGRAMS,
and the means for indicating compliance.
In info...
view more

    • sale 15% off
    • Standard
      90 pages
      English and French language

IEC 63073-1:2020 specifies terminology and test methods for describing the characteristics of SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT) systems designed specifically for tomographic cardiac imaging. This includes dedicated systems or general purpose systems with dedicated sub-systems which are not included in the scope of IEC 61675-2.

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

IEC 60522-1:2020 applies to X-RAY TUBE ASSEMBLIES and to FILTERING MATERIAL, in medical diagnostic applications up to a HIGH VOLTAGE of 150 kV. For HIGH VOLTAGES greater than 50 kV, this document applies to X-RAY TUBE ASSEMBLIES with tungsten or tungsten-alloy TARGETS only.
IEC 60522-1:2021 defines the concept of PERMANENT FILTRATION of X-RAY TUBE ASSEMBLIES, and it defines the term FILTERING MATERIAL.
Methods are given to determine the PERMANENT FILTRATION of an X-RAY TUBE ASSEMBLY and for de...
view more

    • sale 15% off
    • Standard
      37 pages
      English and French language

IEC TR 60522-2:2020 provides guidance on quality equivalent filtration and permanent filtration with regards to the requirements of IEC 60522-1 and its modifications versus IEC 60522:1999.

    • sale 15% off
    • Technical report
      35 pages
      English language

IEC 63073-1:2020 specifies terminology and test methods for describing the characteristics of SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT) systems designed specifically for tomographic cardiac imaging. This includes dedicated systems or general purpose systems with dedicated sub-systems which are not included in the scope of IEC 61675-2.

    • sale 15% off
    • Standard
      58 pages
      English and French language

This report is supplement 11 to the DICOM standard. It defines a number of information objects applicable to the domain of radiation oncology. The intent of these objects is to support the transfer of radiotherapy-related data between devices found within and outside a radiotherapy department.

    • sale 15% off
    • Technical report
      88 pages
      English language

This part of IEC 61223 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when
used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and
dose.
Excluded from the scope of this document are:
– MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC
TOMOSYNTHESIS;
– 2D images synthesised from the tomosynthesis images;
– reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS;
– CT SCANNERS covered by IEC 61223-3-5.
This documen...
view more

    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

2020-01-08 CV: BT decision (D164/C119) to proceed to publication without link to legislation
2019-11-07 mah: consultant assessment missing: blocked.
2019-11-12 - JO: BT document to remove link to the MDD under review

    • sale 10% off
    • Amendment
      20 pages
      English language
    • e-Library read for
      1 day

2020-03-17-JO- BT decision BT164/DG11529/DV to remove the link to the MDD (93/42/EEC)
Publication on hold due to negative assessment

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

EN-IEC 60580 specifies the performance and testing of DOSE AREA PRODUCT METERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. This document is applicable to the following types of DOSE AREA PRODUCT METERS: a) FIELD-CLASS DOSE AREA PRODUCT METERS normally used for the measurement of DOSE AREA PRODUCTS during MEDICAL RADIOLOGICAL EXAMINATIONS; b) REFERENCE-CLASS DOSE AREA PRODUCT METERS normally used for...view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

IEC 61223-3-6:2020 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose. Excluded from the scope of this document are: - MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC TOMOSYNTHESIS; - 2D images synthesised from the tomosynthesis images; - reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS; - CT SCANNERS covered by IEC 61223-3-5. IEC 61223-3-6:2020 define...view more

    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

2020-01-08 CV: BT decision (D164/C119) to proceed to publication without link to legislation
2019-11-07 mah: consultant assessment missing: blocked.
2019-11-12 - JO: BT document to remove link to the MDD under review

    • sale 10% off
    • Amendment
      20 pages
      English language
    • e-Library read for
      1 day

2020-03-17-JO- BT decision BT164/DG11529/DV to remove the link to the MDD (93/42/EEC)
Publication on hold due to negative assessment

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

IEC 60580:2019 is available as IEC 60580:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60580:2019 specifies the performance and testing of Dose Area Product Meters intended to measure Dose Area Product and/or Dose Area Product Rate to which the Patient is exposed during Medical Radiological Examinations. This document is applicable to the following types of Dose Area Product Meters: a)...view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

IEC 61223-3-6:2020 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose.
Excluded from the scope of this document are:
- MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC TOMOSYNTHESIS;
- 2D images synthesised from the tomosynthesis images;
- reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS;
- CT SCANNERS covered by IEC 61223-3-5.
IEC 61223-3-6:2020 ...
view more

    • sale 15% off
    • Standard
      108 pages
      English and French language

IEC 60601-2-28:2010 establishes particular basic safety and essential performance requirements for X-ray tube assemblies for medical diagnosis. This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision. The second edition of this particular standard has been prepared to fit IEC 60601-1:2005 (the third edition of IEC 60601-1), which is referred to as the general standard.

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

This document applies to CT SCANNERS that conform to IEC 60601-2-44:2009, IEC 60601-2-44:2009/AMD1:2012 and IEC 60601-2-44:2009/AMD2:2016. IEC 60601-2-44 and this document - defines the essential parameters which describe the performance of CT SCANNERS wih regard to image quality, RADIATION OUTPUT and PATIENT positioning; the list of parameters to be tested can be found in 4.3, - defines the methods of testing the essential parameters, and - evaluates compliance with the tolerances of the parame...view more

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day

This document applies to - CT SCANNERS that are able to display and report CTDIVOL in accordance with IEC 60601-2-44, and - RADIATION dose index monitoring software (RDIMS) for the purpose of calculating, displaying and recording the SIZE SPECIFIC DOSE ESTIMATE (SSDE) and its associated components. Specifically, this document provides standardized methods and requirements for calculating, displaying, or recording of SSDE, SSDE(z), WATER EQUIVALENT DIAMETER (DW), and DW(z), where z represents a s...view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day

IEC 60601-2-22:2019 is available as IEC 60601-2-22:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60601-2-22:2019 applies to the Basic Safety and Essential Performance of laser equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications, intended for use on humans or animals, classified as Laser Product of Class 1C where the Enclosed Laser is of Class 3B...view more

    • sale 15% off
    • Standard
      62 pages
      English and French language