11.020.99 - Other standards related to health care in general
Other standards related to health care in general
Autres normes relatives a la santé en général
Drugi standardi v zvezi z zdravstvom na splošno
General Information
This document specifies requirements and recommendations for healthcare interpreting services in spoken and signed communication. It is applicable to all situations requiring healthcare interpreting, where the parties involved need to communicate using spoken or signed language, to treat a health-related issue. It is intended for interpreting service providers and healthcare interpreters.
- Standard19 pagesFrench language
sale 15% off- Draft19 pagesFrench language
sale 15% off- Standard18 pagesEnglish language
sale 15% off- Draft18 pagesEnglish language
sale 15% off- Draft23 pagesFrench language
sale 15% off- Draft20 pagesEnglish language
sale 15% off
IEC 63240-2:2020 specifies the AAL architecture model.
This document defines concepts and introduces terminology. IEC 63240-1 provides generic rules for designers of AAL systems and services with the aim to facilitate systems design and enable interoperability between components. This document provides a framework to analyse use cases on a common view and terminology, which is a foundation for communication to discuss the interoperability of the components of the AAL system. This document allow...view more
- Standard19 pagesEnglish language
sale 15% off
IEC 63240-1:2020 specifies the AAL reference architecture.
This document defines concepts and introduces terminology. It provides generic rules for designers of AAL systems and services with the aim to facilitate systems design and enable interoperability between components.
This document identifies safety, security, privacy, and other requirements for AAL systems such as usability, accessibility, and trustworthiness (reliability, resilience).
- Standard13 pagesEnglish language
sale 15% off
This document specifies the general storage requirements for raw materials and decoction pieces. It is applicable to the storage of raw materials and decoction pieces used in traditional Chinese medicine.
- Standard51 pagesEnglish language
sale 15% off- Draft51 pagesEnglish language
sale 15% off
IEC TS 63134:2020 identifies AAL scenarios and use cases based on real-world applications and requirements. The use cases provide a practical context for considerations of interoperability and standards based on user experience. Use cases provide a context for utilizing existing standards and identifying further standardization work. User requirements have also been identified.
This document also highlights potential areas for standardization in the AAL environment to ensure safety, security, p...view more
- Technical specification113 pagesEnglish language
sale 15% off
This document defines terms for the theory, technology and methods of Chinese Materia Medica processing. It is not applicable to Kampo medicine.
- Standard24 pagesEnglish language
sale 15% off
This document specifies an information model within the field of Chinese materia medica processing. It defines a set of domain constraints of sanctioned characteristics, each composed of a relationship and an applicable information model. This model aims at representing the concepts applicable to Chinese materia medica processing in the making of decoction pieces. This document is not applicable to Japanese traditional Kampo medicine.
- Technical specification11 pagesEnglish language
sale 15% off
This document establishes the core classification framework for the integration of clinical terms from traditional Chinese medicine (TCM) and Western medicine. This structure supports terminology integration in standardized electronic medical records, including professional clinical terms in TCM and Western medicine. Non-technical terms for electronic medical records are also included.
- Technical specification8 pagesEnglish language
sale 15% off
This document specifies the general requirements for Chinese materia medica specification. This specification is relevant for dividing Chinese materia medica into categories. It provides guidelines for writing the specifications of individual Chinese materia medica.
- Standard9 pagesEnglish language
sale 15% off
This part of IEC 61340 applies to facilities that provide healthcare including hospitals, care
centres and clinics.
This document provides technical requirements and recommendations for controlling
electrostatic phenomena in healthcare facilities, which includes requirements for equipment,
materials, and products used to control static electricity.
The requirements of this document do not apply to medical electrical equipment specified in
IEC 60601-1 [1] 1 and in vitro diagnostic (IVD) med...view more
- Standard27 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61340-6-1:2018 applies to facilities that provide healthcare including hospitals, care centres and clinics. This document provides technical requirements and recommendations for controlling electrostatic phenomena in healthcare facilities, which includes requirements for equipment, materials, and products used to control static electricity. The requirements of this document do not apply to medical electrical equipment specified in IEC 60601-1 and in vitro diagnostic (IVD) medical equipment s...view more
- Standard27 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61340-6-1:2018 applies to facilities that provide healthcare including hospitals, care centres and clinics. This document provides technical requirements and recommendations for controlling electrostatic phenomena in healthcare facilities, which includes requirements for equipment, materials, and products used to control static electricity. The requirements of this document do not apply to medical electrical equipment specified in IEC 60601-1 and in vitro diagnostic (IVD) medical equipment s...view more
- Standard45 pagesEnglish and French language
sale 15% off
This Technical Specification provides guidance for managing security of (high risk) chemical, biological, radioactive, nuclear or Explosive materials, such as those covered by the EU CBRN action plan, that are used within healthcare facilities (HCF); it covers the lifecycle of such materials within a HCF’s span of control. In this Technical Specification these materials are referred to as ‘CBRNE materials’.
It covers the protection of (high risk) CBRNE materials used in healthcare facilities ag...view more
- Technical specification37 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Specification provides guidance for managing security of (high risk) chemical, biological, radioactive, nuclear or Explosive materials, such as those covered by the EU CBRN action plan, that are used within healthcare facilities (HCF); it covers the lifecycle of such materials within a HCF’s span of control. In this Technical Specification these materials are referred to as ‘CBRNE materials’.
It covers the protection of (high risk) CBRNE materials used in healthcare facilities ag...view more
- Technical specification37 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 18662-1:2017 specifies the basic vocabulary for the Chinese Materia Medica (CMM), including most commonly used CMM species. Each term is provided a Latin name, Chinese name, Pinyin name and English name. Source-related definition of applicable parts and botanical name(s) of the plant, zoological family name of the animal, or mineral stated with mineral or rock title and active ingredients are given as note(s) for each item. ISO 18662-1:2017 is intended to be used by those engaged in the prac...view more
- Standard143 pagesEnglish language
sale 15% off
1.1 This practice outlines the irradiator installation qualifi-cation program and the dosimetric procedures to be followed during operational qualification and performance qualification of the irradiator. Procedures for the routine radiation process-ing of blood product (blood and blood components) are also given. If followed, these procedures will help ensure that blood product exposed to gamma radiation or X-radiation (bremsstrahlung) will receive absorbed doses with a specified range. 1.2 This pr...view more
- Standard13 pagesEnglish language
sale 15% off
ISO 19465:2017 specifies a categorial structure within the subject field of traditional Chinese medicine (TCM) clinical practice. It describes the upper-level categories of TCM clinical terms and the nomenclature of the hierarchical categories. It is applicable only to clinical terminological systems in TCM disciplines, not to a comprehensive categorial structure of TCM, the conceptual definition of the hierarchy categories, and terms for individual TCM concepts. The following are considered out...view more
- Standard8 pagesEnglish language
sale 15% off
This part of ISO 9241 establishes guidelines for the reduction of photosensitive seizures, one of three major undesirable biomedical effects, induced by images presented on electronic visual displays. The guidelines address the conditions essentially produced by electronic visual image contents presented at home and in work environments, but not by electronic visual display. The guideline in the document is for the protection of the vulnerable section of the viewing population who are photosensi...view more
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
The standard will specify requirements for planning, establishing, implementing, operating, monitoring, reviewing, maintaining and continually improving a documented security management system in healthcare facilities.
- Technical specification39 pagesEnglish language
sale 10% off- e-Library read for1 day
The particular requirements of this part of HD 60364 apply to electrical installations in medical locations so as to ensure safety of patients and medical staff. These requirements, in the main, refer to hospitals, private clinics, medical and dental practices, health care centres and dedicated medical rooms in the work place.
The requirements of this part do not apply to ME equipment. This part also applies to electrical installations in locations designed for medical research.
NOTE 1 It may ...view more
- Corrigendum1 pageEnglish language
sale 10% off- e-Library read for1 day