Water meters - Part 4: Additional functionalities

This European Standard specifies definitions, requirements and testing of additional functionalities for water
meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in
response to EU/EFTA Mandate M/441 EN. These AFDs are to be considered as “ancillary devices" as defined
in EN ISO 4064-1 and EN ISO 4064-4.
This European Standard does not cover the changing of metrological software within the meter or the
upload/download of metrological software.

Wasserzähler - Teil 4: Zusätzliche Funktionalitäten

Definition, Anforderungen und Prüfung hinsichtlich zusätzlichen Funktionalitäten für Wasserzähler in Kombination mit Zusatzfunktionsgeräten (ZFG) nach Teil 1 der EN 14154 entsprechend EU/EFTA-Mandat M/441 EN.
Die vorliegende Norm gilt für ZFG an Aufstellungsorten mit geringfügigen Erschütterungen und Stößen sowie an:
-   geschlossenen Aufstellungsorten (Innen- oder Außenbereich mit vom Hersteller festgelegtem Schutz) mit kondensierender oder nicht-kondensierender Feuchtigkeit;
oder, sofern vom Hersteller festgelegt:
-   offenen Aufstellungsorten (Außenbereich ohne Abdeckung) mit kondensierender oder nicht-konden-sierender Feuchtigkeit;
-   Aufstellungsorten, die vorübergehender Sättigung unterliegen,
sowie an Aufstellungsorten mit elektromagnetischen Störungen entsprechend jenen, deren Auftreten in Wohn- und Gewerbegebäuden oder ähnlichen Gebäuden wahrscheinlich ist.
Die vorliegende Norm behandelt nicht die Änderung messtechnischer Software innerhalb des Zählers oder deren Hoch-/Herunterladen.

Compteurs d'eau - Partie 4: Fonctions additionnelles

Définition, exigences et essai des fonctionnalités additionnelles des compteurs d'eau, en combinaison avec les dispositifs à fonctionnalités additionnelles (AFD) normalisés dans la Partie 1 de l'EN 14154 en réponse au mandat UE/EFTA M/441 EN.
La présente norme s'applique aux AFD qui sont installés à des endroits où se produisent des vibrations et des chocs peu significatifs et :
-   dans des lieux fermés (intérieurs ou extérieurs avec protection spécifiée par le fabricant) avec condensation ou avec humidité sans condensation ;
ou, si le fabricant le spécifie :
-   dans des lieux ouverts (à l'extérieur, sans aucune protection) avec humidité de condensation ou avec humidité sans condensation ;
-   à des emplacements sujets à une saturation temporaire,
et à des emplacements où existent des perturbations électromagnétiques correspondant à celles que l'on est susceptible de trouver dans des bâtiments résidentiels, commerciaux ou dans des bâtiments similaires.
La présente norme ne traite pas la modification du logiciel de métrologie dans le compteur ou le téléchargement d'un logiciel de métrologie.

Vodomeri - 4. del: Dodatne funkcije

Ta evropski standard določa definicije, zahteve in preskušanje dodatnih funkcij za vodomere, brez meroslovnega vpliva, v kombinaciji z napravami z dodatnimi funkcijami (AFD) in kot odziv na mandat EU/EFTA M/441 EN. Te naprave z dodatnimi funkcijami se upoštevajo kot »pomožne naprave«, kot je definirano v standardih EN ISO 4064-1 in EN ISO 4064-4.
Ta evropski standard ne zajema sprememb meroslovne programske opreme merilnika ali
prenosa/nalaganja meroslovne programske opreme.

General Information

Status
Withdrawn
Publication Date
14-Dec-2014
Withdrawal Date
04-Apr-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
05-Apr-2023
Due Date
28-Apr-2023
Completion Date
05-Apr-2023

Relations

Buy Standard

Standard
EN 14154-4:2015
English language
23 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vodomeri - 4. del: Dodatne funkcijeWasserzähler - Teil 4: Zusätzliche FunktionalitätenCompteurs d'eau - Partie 4: Fonctions additionnellesWater meters - Part 4: Additional functionalities91.140.60Sistemi za oskrbo z vodoWater supply systemsICS:Ta slovenski standard je istoveten z:EN 14154-4:2014SIST EN 14154-4:2015en,fr,de01-februar-2015SIST EN 14154-4:2015SLOVENSKI
STANDARD



SIST EN 14154-4:2015



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14154-4
November 2014 ICS 91.140.60 English Version
Water meters - Part 4: Additional functionalities
Compteurs d'eau - Partie 4: Fonctionnalités additionnelles Wasserzähler - Teil 4: Zusätzliche Funktionalitäten This European Standard was approved by CEN on 6 September 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14154-4:2014 ESIST EN 14154-4:2015



EN 14154-4:2014 (E) 2 Contents Page Foreword .4 Introduction .5 1 Scope .6 2 Normative references .6 3 Terms and definitions .6 4 General requirements .7 4.1 Types of additional functionality devices and requirements .7 4.2 Connection requirements .8 4.3 Environmental conditions .8 4.4 Security .9 4.4.1 General .9 4.4.2 Software, data and hardware security .9 4.4.3 Firmware upgrade of AFD .9 4.4.4 Software identification .9 4.5 Power supply .9 4.6 Data storage . 10 4.7 Clock requirements . 10 4.7.1 General . 10 4.7.2 Clock synchronisation . 10 4.7.3 Clock setting . 10 4.8 Marking . 10 4.8.1 Requirements . 10 4.8.2 Test . 11 4.9 Documentation . 11 4.9.1 General . 11 4.9.2 Declaration of conformity . 11 4.9.3 Instruction manual . 11 4.10 Display . 12 4.10.1 General . 12 4.10.2 Requirements . 12 4.10.3 Test . 12 4.11 Metrological influence . 12 4.11.1 Requirement . 12 4.11.2 Test . 12 4.12 Input to AFD / Output from AFD . 13 4.12.1 General . 13 4.12.2 Requirement . 13 4.12.3 Test . 13 5 Additional functionalities . 13 5.1 General . 13 5.2 Use cases . 13 5.2.1 Scheduled read . 13 5.2.2 Pre-programmed reading date . 14 5.2.3 On demand read. 14 5.2.4 History of consumption . 14 5.2.5 Background leak . 14 5.2.6 Burst . 15 5.2.7 Reverse flow . 15 SIST EN 14154-4:2015



EN 14154-4:2014 (E) 3 5.2.8 Zero flow . 16 5.2.9 Tamper of AFD . 16 5.2.10 Tamper of meter . 16 5.2.11 Battery low . 16 5.2.12 Presence of air . 17 5.2.13 Access profiles . 17 6 Environmental considerations . 17 Annex A (normative)
Declaration of conformity to EN 14154-4 . 18 Annex B (informative)
Smart Metering, overview, core functionalities and definitions . 19 B.1 General . 19 B.2 M2M Gateway . 19 B.3 Clusters . 20 B.4 Primary Use Cases . 20 B.5 Secondary Use Cases . 20 B.6 Primary Actors . 20 B.7 Actors . 20 B.8 Use Cases . 20 Annex C (informative)
References to EN 14154-1, EN 14154-2 and EN 14154-3 and
EN ISO 4064-1, EN ISO 4064-2, EN ISO 4064-3, EN ISO 4064-4, EN ISO 4064-5 . 21 Bibliography . 23
SIST EN 14154-4:2015



EN 14154-4:2014 (E) 4 Foreword This document (EN 14154-4:2014) has been prepared by Technical Committee CEN/TC 92 “Water meters”, the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2015, and conflicting national standards shall be withdrawn at the latest by May 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 5 Introduction This European Standard has been defined as part of the work being undertaken by the European Standards Organizations (CEN/CENELEC/ETSI) under the Commission Mandate M/441. This standard utilizes the six functionalities agreed by the Smart Meters Coordination Group (SM-CG) (see Annex B) as the basis for its additional functionalities. It is not required for the Additional Functionality Device (AFD) to incorporate all functions defined in this standard. Communications for water meters are outside the scope of this standard and are covered by the appropriate parts of EN 13757-1, EN 13757-2, EN 13757-3, EN 13757-4, EN 13757-5 and EN 13757-6 which provide a number of protocols and transport layers for meter communications for Gas, Water and Heat meters. The additional functionality for water meters can be provided by a number of methods; these are illustrated below, see Figure 1, and described in detail within this standard. The AFD can be integrated in the meter, attached to the meter or remote from the meter. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 6 1 Scope This European Standard specifies definitions, requirements and testing of additional functionalities for water meters, without metrological impact, in combination with Additional Functionality Devices (AFD) and in response to EU/EFTA Mandate M/441 EN. These AFDs are to be considered as “ancillary devices" as defined in EN ISO 4064-1 and EN ISO 4064-4. This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software. NOTE
A manufacturer can claim compliance only for additional functionalities described in this European Standard. It is not mandatory that an AFD complies with all additional functionalities described herein. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 14154-1, Water meters – Part 1: General requirements EN 14154-2, Water meters – Part 2: Installation and conditions of use EN 14154-3, Water meters – Part 3: Test methods and equipment EN ISO 4064-1, Water meters for cold potable water and hot water - Part 1: Metrological and technical requirements (ISO 4064-1) EN ISO 4064-2, Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2) EN ISO 4064-4, Water meters for cold potable water and hot water - Part 4: Non-metrological requirements not covered in ISO 4064-1 (ISO 4064-4) EN ISO 4064-5, Water meters for cold potable water and hot water - Part 5: Installation requirements (ISO 4064-5) EN 60529:1991, Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989) 3 Terms and definitions The terms, definitions and symbols of EN ISO 4064-1, EN ISO 4064-2, EN ISO 4064-4 and EN ISO 4064-5, EN 14154-1, EN 14154-2 and EN 14154-3 apply. NOTE Additionally for the purposes of this part of the European Standard, the following terms and definitions only related to additional functionalities apply. 3.1 functionality process which constantly or at defined intervals, automatically or on demand, performs specific activities such as sampling data, reading a data set, verifying or changing a status, or activating a switch 3.2 additional functionality functionality that a smart meter provides, over and above the metrological functionality covered by the Measuring Instruments Directive SIST EN 14154-4:2015



EN 14154-4:2014 (E) 7 3.3 additional functionality device device providing any additional functionality 3.4 additional functionality device type 1 (AFD1) additional functionality device integrated into the meter 3.5 additional functionality device type 2 (AFD2) additional functionality device directly attached to the meter 3.6 additional functionality device type 3 (AFD3) additional functionality device remotely connected to the meter 3.7 automatic meter reading technology for obtaining metering data from an on-site meter by communication from a remote access point 3.8 universal time coordinated (UTC) world time, without daylight savings 3.9 reading primary indication of the total volume passed through the meter 3.10 metrological software software identified during the type testing examination, which is part of the meter and is critical to its metrological characteristics 3.11 register Indication of the specific section in the memory of the control and metering unit that records data as determined by the programme in the unit 3.12 event condition requiring action or to log an action 3.13 event log temporary or mid-term memorized listing of events, containing their occurrence, actions taken and their reset 3.14 interface point or means of interaction between two systems 4 General requirements 4.1 Types of additional functionality devices and requirements The additional functionality shall be provided by one of the following devices: — AFD1; where all functions are within the same metrological enclosure as the meter; SIST EN 14154-4:2015



EN 14154-4:2014 (E) 8 — AFD2; where the AFD is attached directly to the meter. The manufacturer shall declare the appropriate device compatibility; — AFD3; where the AFD is located remotely and connected to the meter. The manufacturer shall declare the appropriate device compatibility.
Figure 1 — Additional functionality devices 4.2 Connection requirements The AFD2 and AFD3 shall be connected to the meter and tested as a combined unit in all the tests given in 4.11.2 to ensure the connection of the AFD to the meter has no metrological influence. The connection of the AFD to the meter or any labelling on the meter or the AFD shall not obscure or damage any metrological seal of the meter. The primary indication on the meter shall not be obscured by the connection of the AFD and the indicating device shall be accessible to the consumer without the use of tools. 4.3 Environmental conditions The AFD shall work with the meter at all operating conditions of the meter as required by the appropriate standards. Any AFD should be suitable to meet one of the environmental classes from EN ISO 4064-1, A.2 and A.3 and the related tests. An AFD3 may have a different environmental class to that of the meter. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 9 4.4 Security 4.4.1 General The AFD shall be constructed in such a way that any unauthorized intervention shall either cause permanently visible damage to the AFD or its protective seals, or creates a report in the event log. Any physical seals shall be visibly fixed, and easily accessible. 4.4.2 Software, data and hardware security 4.4.2.1 Requirement When tested in accordance with 4.4.2.2 the requirements below shall be met. All available connections, ports and interfaces of the AFD which can be used for unauthorized adjustment of the AFDs characteristics and additional functionality shall be effectively secured by protective seals. No access shall be allowed to software and firmware by unauthorised persons. Software and data shall be protected against accidental or intentional changes by the breaking of a physical seal or by using an electronic seal. For electronic seals the following requirements shall be met: a) access shall only be obtained by using a password or a code; b) unauthorized intervention shall be registered in the event log and the type of intervention identified, and where available date and time to be included. In the case of intended consumer access to the AFD, it shall be ensured that the access by the consumer cannot inadvertently drain the battery capacity, where applicable. 4.4.2.2 Test Compliance with the above requirements shall be checked by visual inspection and evaluation of the manufacturer’s technical documentation. 4.4.3 Firmware upgrade of AFD This part of the standard covers non-metrological upgrades only, providing there is clear separation between the metrological and non-metrological functions. Following any upgrade the information/functionality of the AFD shall be as declared by the manufacturer. Any data still present shall be the same as prior to the upgrade. NOTE An example of a suitable routine is given in the WELMEC Guide 7.2. 4.4.4 Software identification The software (including version) shall have an unambiguous identifier that is retrievable. 4.5 Power supply The power supply of the AFD shall comply with EN ISO 4064-1, EN ISO 4064-4 and EN 14154-1 and shall be tested accordingly. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 10 4.6 Data storage The AFD shall be capable of storing data such as interval and event data. The manufacturer shall declare which data are stored and how to access the stored data. The stored data shall be retained in the event of power failure as tested according to EN 14154-3 and EN ISO 4064-2. 4.7 Clock requirements 4.7.1 General Stored data shall be time stamped. The time stamps shall be generated by a clock which gives: — a relative time stamp, or — a non-synchronized time stamp, or — a synchronized time stamp. It is recommended that the synchronized time stamp within the AFD uses UTC. The accuracy of the time stamp shall be suitable for its intended use. 4.7.2 Clock synchronisation If the manufacturer declares that the AFD has a clock that can be synchronised with the clock of the meter, then it shall be possible to carry out this synchronization. A record shall also be placed in the event log showing what action was taken. 4.7.3 Clock setting If the manufacturer allows setting of the clock, access shall only be achieved by the use of an electronic seal or the breaking of a physical seal. A record shall also be placed in the event log showing what action was taken. 4.8 Marking 4.8.1 Requirements When tested in accordance with 4.8.2 the AFD shall as a minimum be marked as follows: a) the number and date of this standard; b) identification mark or name of the manufacturer; c) serial number and year of manufacture; d) mark with respective IP rating (EN 60529:1991); e) ambient temperature range; f) information about the type of battery (for security, transport and recycling purposes); g) any additional marking as required by legislation. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 11 With the exception of b), c) and g), if all applicable information cannot be shown on the AFD this shall be provided on the packaging or with the documentation provided. 4.8.2 Test This test is carried out by visual inspection. 4.9 Documentation 4.9.1 General The following information shall be provided with each AFD or group of AFD’s used in the same location. 4.9.2 Declaration of conformity For each AFD a Declaration of Conformity as per Annex A shall be available in written form or electronic format and shall identify the name and address of the manufacturer and the date of issue. 4.9.3 Instruction manual The operating instructions manual shall cover installation, operation and maintenance and shall be available in written form or electronic format and shall identify the name and address of the manufacturer and the date of issue. Each AFD or meter-AFD combination or packaging units of those shall be delivered with installation, operation and maintenance appropriate instruction manuals, including: — safe use and hazards arising from misuse and particular features of the design when appropriate; — rated operating conditions; — mechanical and electromagnetic environment classes; — safe disposal and/or recycling guidance; — conditions for compatibility with interfaces and type of communication protocol, and — storage requirements. The manuals may include the following optional information: — possible installation positions; — safety requirements concerning commissioning and de-commissioning procedures; — statement if a maintenance is possible and a relevant instruction; — way of controlling the proper installation and operation; — provisions, if any, for transport and handling; — how to trace the right spare parts, and — a description of each of the additional functionalities. SIST EN 14154-4:2015



EN 14154-4:2014 (E) 12 4.10 Display 4.10.1 General This subclause specifies general requirements for an electronic display that may be incorporated in the AFD. 4.10.2 Requirements Displayed data that is consumer relevant shall be easily legible and available without the use of tools. When tested in accordance with 4.10.3, information shall be indicated either on: a) the display fitted to the meter; b) the display of an AFD; c) a combination of the above. The information and flags shall be displayed by means of user action or by means of automatic and sequential scrolling for at least 10 seconds: The identification and the unit of each information or parameter shall be clear and unambiguous. The manufacturer shall declare what information can be displayed. 4.10.3 Test A test shall be executed by visual inspection. 4.11 Metrological influence 4.11.1 Requirement When tested in accordance with 4.11.2, the AFD shall have no influence on the metrological characteristics of the meter. If the AFD provides a facsimile/copy of the meter’s results, it shall be tested in accordance with 4.11.2 to ensure these results are identical to those on the meter. When tested in accordance with 4.11.2 the AFD shall operate with the interfaces specified by the manufacturer and display the information as specified by the manufacturer. 4.11.2 Test Test the meter with the AFD incorporated according to the appropriate standard, i.e. EN ISO 4064-1 to ensure conformity. Verify the AFD is interoperable with those interfaces specified by the manufacturer. In case of AFD2 or AFD3, examine the meter and AFD and ensure there is the possibility to apply a protective seal between the AFD and the meter. With water passing through the meter under test at the flow rates of Q1 and Q3, operate each additional function that could have an effect on the metrological characteristics of the meter separately. Operate each additional function as specified by the manufacturer continuously for 1 h or for a minimum of 10 operations at Q1 and Q3. The meter performance shall be within the relevant MPE. Establish a reference result by repeating the identical test procedure with either; SIST EN 14154-4:2015



EN 14154-4:2014 (E) 13 — the same meter under test with the additional functionalities of the AFD completely disabled, or — the same meter with a standard counter without the additional functionalities. Compare the value reading of the established reference to the value reading of the meter under test and ensure that the reading has not deviated by more than one third of the MPE. If the AFD provides a facsimile/copy of the meter under test results, verify that the results provided by the AFD are identical to those on the meter under test. 4.12 Input to AFD / Output from AFD 4.12.1 General The manufacturer shall specify the interface to the AFD (e.g. incremental volume pulses or data stream). 4.12.2 Requirement The manufacturer shall specify the proper connections to and from the AFD. The AFD instructions shall define the corresponding counterparts or the electrical characteristics and parameters, the type and method of connection, installation, operating system of the AFD. When tested in accordance with 4.12.3, a signal as described by the manufacturer shall be detected. 4.12.3 Test Connect in accordance with the manufacturer's instructions and ensure a signal is recognized and correct assembly is obvious. 5 Additional functionalities 5.1 General The additional functionalities to be provided by the AFD are to be described in full by the manufacturer, and shall comply with the tests described below. The additional functionalities described below are not mandatory and are offered at the
...