SIST EN 12221:2026
(Main)Child care articles - Changing units and changing pads for domestic use - Safety requirements and test methods
- Abstract
This document specifies safety requirements and test methods for changing units, changing pads and changing unit accessories for domestic use.
This document only covers the function of the item as a changing unit. If the item can be converted or used for another function (e.g. cots, storage furniture, bath tubs and stands, etc.), other relevant European Standards apply.
The changing unit can be foldable and can be fitted with a child bathtub or other additional items.
- Status
- Published
- Public Enquiry End Date
- 19-Jan-2024
- Publication Date
- 18-Jun-2026
- Technical Committee
- OTR - Child use and care article
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 10-Jun-2026
- Due Date
- 15-Aug-2026
- Completion Date
- 19-Jun-2026
- Directive
- 2001/95/EC - General product safety
SIST EN 12221:2026 is the Slovenian adoption of EN 12221:2026. It specifies safety requirements and test methods for changing units, changing pads and changing unit accessories for domestic use. In practice, it tells manufacturers and test labs how to check that the changing surface, barriers, folding parts, materials and product information reduce the main hazards for a child during changing.
What does SIST EN 12221:2026 specify?
SIST EN 12221:2026 covers only the changing-unit function of the product. If a product can also be used as a cot, storage furniture, bath tub, stand or another item, the relevant European Standards for those other functions apply as well.
The document is organized into Clauses 1 to 9, plus Annex A. The main technical content is in the test equipment, test conditions, hazard requirements and product information clauses.
| Annex | What it covers |
|---|---|
| Annex A | Rationales for selected requirements in Clauses 6 to 8 |
The main clauses are:
- Clause 4 - test equipment and probes
- Clause 5 - general test conditions and the protected volume
- Clause 6 - chemical hazards
- Clause 7 - thermal hazards
- Clause 8 - mechanical hazards
- Clause 9 - product information, marking and instructions
What are the key requirements of SIST EN 12221:2026?
The standard is built around a protected volume and controlled test conditions
SIST EN 12221:2026 uses a defined protected volume for the child area, measured above and around the changing surface. Safety checks in Clauses 6 to 8 focus on what the child can reach while lying on the unit.
Clause 5 also fixes the way products are prepared and tested. Samples are conditioned indoors, products are tested as delivered and assembled according to the instructions, and the most onerous intended configuration is used. That matters because a product must pass in the way it is actually sold and used, not only in an easy configuration.
Chemical and thermal hazards are limited on the materials inside the protected volume
Clause 6 limits migration of certain elements from materials on surfaces within the protected volume and limits formaldehyde in textile components there. The standard also points to the relevant test methods in EN 71-3 and EN ISO 14184-1. For buyers and quality teams, that means the materials close to the child are treated as safety-critical, not just the structure.
Clause 7 applies flammability-related checks to textiles, coated textile supports and plastic coverings. These materials should not show surface flash and should meet the stated flame-spread condition when tested to EN 71-2. In practical terms, the changing area is expected to be made from materials that do not spread flame rapidly if they meet an ignition source.
The changing surface must be large enough and must not trap the child
Clause 8.2 sets minimum changing-area dimensions for changing units and changing unit accessories. That is the basic size check: the child should fit on the support without being crowded to the edge.
Clauses 8.3 and 8.4 address entrapment and moving-part hazards. Finger, limb, head, neck and torso openings are checked with defined probes, and accessible compression or shear points in the protected volume must not close to hazardous gaps during use, movement or external loading. In practice, this means openings, hinges, folding joints and similar features must be designed so they do not trap fingers or larger body parts.
The child must be protected from falling, folding, cords and small parts
Clause 8.5 requires barriers and prohibits harness systems, belts, toys and toy bars on the changing function. The barrier layout depends on the shape of the changing area, and barrier performance is checked with inclined test arrangements and test masses. For users, this means the unit must rely on its structure and barriers to keep the child in place, not on restraint accessories.
Clause 8.6 covers foldable products and locking mechanisms. Folding units that could collapse while the child is supported must have locking arrangements and must resist unintentional release and repeated loading. This matters because accidental folding can create both fall and crush hazards.
Clause 8.7 limits cords, ribbons and similar parts in the protected volume, and Clause 8.8 limits detachable small parts and the accessibility of filling materials. Clauses 8.9 and 8.10 cover packaging suffocation risk and hazardous edges, corners and protruding parts. Together, these requirements reduce strangulation, choking, ingestion, suffocation and cut hazards.
The structure, stability and mobility of the unit are also tested
Clause 8.11 checks structural integrity, including static load, durability and, where relevant, the strength of changing board flaps. Clause 8.12 checks stability for floor standing units, bathtub mounted units and changing unit accessories. Clause 8.13 covers castors, wheels and parking devices, and Clause 8.14 requires effective open stops for extension elements above the changing area.
For day-to-day use, these clauses matter because a product must stay usable after loading, repeated cycling and side forces, and it must not overturn when the child moves or the carer applies a normal force.
Product information is part of safety
Clause 9 requires permanent marking, purchase information and instructions for use. The standard requires the manufacturer or responsible seller to be identified, the product itself to be identified, and clear warnings to be provided in the language of sale.
The instructions also include the intended child weight or age, assembly guidance, maintenance advice, compatibility guidance for changing pads and a warning not to use the product if components are broken or missing. In practice, the document treats labeling and instructions as part of safety control, not as optional paperwork.
What terms does SIST EN 12221:2026 define?
- changing unit - an elevated structure designed to support a child lying down so a caregiver can clean or change the child.
- bathtub mounted changing unit - a changing unit intended to be mounted on an adult household bathtub.
- wall mounted changing unit - a non-standalone changing unit attached to a wall, with or without support legs.
- changing pad - a pad with side barriers made specifically for changing a child; flat mats without barriers are excluded from this term.
- changing unit accessory - an accessory that attaches to a cot, crib or playpen so the combination can be used as a changing unit.
- locking mechanism - an assembly of one or more locking devices and one or more operating devices.
- locking device - the mechanical part that keeps the item in the erected, in-use position.
- protected volume - the space around the changing area where the child can reach and where specific safety requirements apply.
Who uses SIST EN 12221:2026?
SIST EN 12221:2026 is used by manufacturers and designers of baby changing units, changing pads and changing unit accessories who need to build products to a defined safety standard. It is also used by test laboratories that perform the mechanical, chemical and flammability-related checks.
Quality managers, compliance teams and buyers use it to specify what evidence they need from suppliers, especially for barriers, stability, foldability, markings and instructions. Retailers and importers can also use it to verify that product information and warnings match the intended use.
What changed in SIST EN 12221:2026 from the previous edition?
SIST EN 12221:2026 supersedes EN 12221-1:2008+A1:2013 and EN 12221-2:2008+A1:2013. The standard states these main technical changes:
- adoption of a hazard-based format
- unification of the two former parts into one document
- inclusion of changing pads and changing unit accessories
- updated terms and definitions
- updated chemical hazards
- updated thermal hazards
- general update of the mechanical requirements to current practice
- added requirements for accessibility filling materials
- added durability requirements
- revised product information and added specific symbols
- added rationales
Which standards are used with SIST EN 12221:2026?
| Normative reference | What it contributes |
|---|---|
| EN 71-2:2020+A1:2025 | Flammability test methods used for textile, coated textile and plastic coverings |
| EN 71-3:2019+A2:2024 | Migration of certain elements from materials within the protected volume |
| EN ISO 14184-1:2011 | Test method for free and hydrolysed formaldehyde in textile components |
| ISO 48-4:2018 | Shore hardness method used for the rubber layer on the side impactor |
What does the SIST EN 12221:2026 document contain?
SIST EN 12221:2026 contains detailed test equipment descriptions for masses, probes, test floors, walls, bases, beams, impactors, loading pads, abrasive paper and a test rig. It also includes figures that show the probes and test set-ups used for measuring openings, barriers, folding and stability.
Clause 8 gives the practical test methods for size, entrapment, moving parts, falling, folding, cords, small parts, packaging, edges, structural integrity, stability, castors and extension elements. Clause 9 contains the marking, purchase information and instructions that have to accompany the product.
Annex A gives the rationales behind the safety requirements. That annex helps readers understand why the standard focuses on the protected volume, barriers, entrapment, folding, structural integrity and stability.
Relations
- Effective Date
- 01-Jul-2026
- Effective Date
- 01-Jul-2026
- Effective Date
- 08-Apr-2026
- Effective Date
- 08-Apr-2026
- Effective Date
- 08-Apr-2026
Frequently Asked Questions
SIST EN 12221:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Child care articles - Changing units and changing pads for domestic use - Safety requirements and test methods". This standard covers: This document specifies safety requirements and test methods for changing units, changing pads and changing unit accessories for domestic use. This document only covers the function of the item as a changing unit. If the item can be converted or used for another function (e.g. cots, storage furniture, bath tubs and stands, etc.), other relevant European Standards apply. The changing unit can be foldable and can be fitted with a child bathtub or other additional items.
This document specifies safety requirements and test methods for changing units, changing pads and changing unit accessories for domestic use. This document only covers the function of the item as a changing unit. If the item can be converted or used for another function (e.g. cots, storage furniture, bath tubs and stands, etc.), other relevant European Standards apply. The changing unit can be foldable and can be fitted with a child bathtub or other additional items.
SIST EN 12221:2026 is classified under the following ICS (International Classification for Standards) categories: 97.190 - Equipment for children. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 12221:2026 has the following relationships with other standards: It is inter standard links to SIST EN 12221-2:2008+A1:2013, SIST EN 12221-1:2008+A1:2013, SIST EN ISO 14184-1:2011, SIST EN 71-3:2019+A2:2025, SIST EN 71-2:2021+A1:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 12221:2026 is associated with the following European legislation: EU Directives/Regulations: 2001/95/EC, 2023/988/EU; Standardization Mandates: M/264. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 12221:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 changing unit
- 3.2 bathtub mounted changing unit
- 3.3 wall mounted changing unit
- 3.4 changing board flap
- 3.5 changing pad
- 3.6 changing unit accessory
- 3.7 locking mechanism
- 3.8 locking device
- 3.9 operating device
- 3.10 protected volume
- 4 Test equipment
- 4.1 Test mass A
- 4.2 Test mass B
- 4.3 Small parts cylinder
- 4.4 Feeler gauge
- 4.5 Test probes for finger entrapment
- 1 Line ascribed around circumference showing depth of penetration
- 4.6 Test probes for limb entrapment
- 4.7 Test probes for head entrapment
- 4.8 Test floor for floor standing units
- 4.9 Test wall for wall mounted changing units
- 4.10 Test base for bath mounted units
- 4.11 Stops
- 4.12 Test beam
- 4.13 Measuring rod for test beam
- 4.14 Side impactor
- 4.15 Loading pad
- 4.16 Aluminium oxide abrasive paper
- 4.17 Test rig
- 5 General requirements and test conditions
- 5.1 Product conditioning
- 5.2 Test conditions
- 5.3 Application of forces
- 5.4 Tolerances of the test equipment
- 5.5 Determination of protected volume (see A.4.1)
- 5.6 Order of tests
- 6 Chemical hazards (see A.2)
- 6.1 General
- 6.2 Migration of certain elements
- 6.3 Formaldehyde
- 7 Thermal hazards (see A.3)
- 8 Mechanical hazards
- 8.1 Changing pads
- 8.2 Hazards due to inadequate size (see A.4.2)
- 8.3 Entrapment hazards
- 1 PASS
- 2 PASS
- 1 PASS
- 1 PASS
- 2 FAIL
- 8.4 Hazards due to moving parts (see A.4.4)
- 8.5 Hazards due to falling of the child (see A.4.5)
- 8.6 Hazards due to folding of the product (see A.4.6)
- 8.7 Hazards from entanglement in cords, ribbons and similar parts (see A.4.7)
- 8.8 Choking and ingestion hazard (see A.4.8)
- 8.9 Suffocation hazards from plastic packaging (see A.4.9)
- 8.10 Hazards from edges, corners and protruding parts (see A.4.10)
- 8.11 Hazards from inadequate structural integrity (see A.4.11)
- 8.12 Hazards from inadequate stability (see A.4.12)
- 8.13 Castors and wheels
- 8.14 Extension elements
- 9 Product information
- 9.1 General
- 9.2 Marking of the product
- 9.3 Purchase information
- 9.4 Instructions for use
- Annex A
- Bibliography
1 Scope
This document specifies safety requirements and test methods for changing units, changing pads and changing unit accessories for domestic use.
This document only covers the function of the item as a changing unit. If the item can be converted or used for another function (e.g. cots, storage furniture, bath tubs and stands, etc.), other relevant European Standards apply.
The changing unit can be foldable and can be fitted with a child bathtub or other additional items.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 71-2:2020+A1:2025, Safety of toys — Part 2: Flammability EN 71-3:2019+A2:2024, Safety of toys — Part 3: Migration of certain elements EN ISO 14184-1:2011, Textiles — Determination of formaldehyde — Part 1: Free and hydrolysed formaldehyde (water extraction method) (ISO 14184-1:2011) ISO 48-4:2018, Rubber, vulcanized or thermoplastic — Determination of hardness — Part 4: Indentation hardness by durometer method (Shore hardness)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
3.1 changing unit
elevated structure designed to support a child in a lying position for the purpose of allowing a caregiver to clean and/or change the child
3.2 bathtub mounted changing unit
changing unit intended to be mounted on an adult household bathtub
3.3 wall mounted changing unit
non-standalone changing unit intended to be attached to a wall, with or without support legs Note 1 to entry: A floor standing changing unit for which the manufacturer recommends an additional fixation to a wall is not considered to be a wall mounted changing unit
SIST EN 12221:2026 EN 12221:2026 (E)
3.4 changing board flap
changing surface that is movable or removable for storage purposes or to provide access to another function, e.g. a bathtub
3.5 changing pad
pad with side barriers specifically designed for the purpose of changing the child Note 1 to entry: Flat mats and similar items without barriers intended only to offer hygienic protection or comfort during changing are not included in the definition.
Note 2 to entry: Outer rims of a pad are considered as barriers if the thickness of the rim is greater than the thickness of the changing surface.
3.6 changing unit accessory
accessory that attaches to a cot, crib or playpen designed to enable the combination to be used as a changing unit
3.7 locking mechanism
assembly of components consisting of one or more locking device(s) and one or more operating device(s)
3.8 locking device
mechanical component that maintains part(s) of the item erected in the position of use (e.g. latch(es), hooks, over centre lock...) which could be deactivated or activated by action(s) on the operating device
3.9 operating device
part of the locking mechanism(s) designed to be activated by the carer through one or several positive action(s)
3.10 protected volume
volume accessible by the child (occupant) when lying on the changing area, where specific safety requirements are necessary
4 Test equipment
4.1 Test mass A
Test mass A is a rigid cylinder (160 ± 5) mm in diameter and (300 ± 5) mm in height, having a mass of +01, 9 kg and with its centre of gravity in the centre of the cylinder. All edges shall have a radius of (5 ± 1)
mm (see Figure 1).
SIST EN 12221:2026 EN 12221:2026 (E) Dimensions in millimetres
Key 1 radius: (5 ± 1) mm Figure 1 — Test mass A
4.2 Test mass B
Test mass B is a rigid cylinder (200 ± 5) mm in diameter and (300 ± 5) mm in height, having a mass of +01, 15 kg and with its centre of gravity in the centre of the cylinder. All edges shall have a radius of (5 ± 1)
mm (see Figure 2).
Dimensions in millimetres
Key 1 radius: (5 ± 1) mm Figure 2 — Test mass B
SIST EN 12221:2026 EN 12221:2026 (E)
4.3 Small parts cylinder
Small parts cylinder for the assessment of small components, having dimensions in accordance with Figure 3.
Dimension in millimetres
Figure 3 — Small parts cylinder
4.4 Feeler gauge
Gauge with a thickness of (0,4 ± 0,02) mm and an insertion edge radius of (3 ± 0,5) mm (see Figure 4). Dimensions in millimetres
Figure 4 — Feeler gauge
4.5 Test probes for finger entrapment
4.5.1 Test probes with hemispherical end
Probes made from plastic or other hard, smooth material, that can be mounted on a force-measuring 0 +01, device, with diameters mm and 12 mm and a full hemispherical end and a line ascribed around
−01, 0 the circumference at 10mm from the hemispherical end, see Figure 5.
SIST EN 12221:2026 EN 12221:2026 (E) Dimensions in millimetres
Key Probe type 7 mm probe 12 mm probe
+01,
Diameter ØA 7
−01,
Radius RB Half of diameter A Half of diameter A
1 Line ascribed around circumference showing depth of penetration
Figure 5 — Test probes with hemispherical end
4.5.2 Test probe for mesh
Mesh probe made from plastic or other hard, smooth material as shown in Figure 6. Dimensions in millimetres
Key Probe type mesh probe
mm Diameter ØA 7 −01,
5,6 mm Diameter ØB −01, Radius RB half of diameter B Figure 6 — Test probe for mesh
SIST EN 12221:2026 EN 12221:2026 (E)
4.5.3 Shape assessment probe
Probe made from plastic or other hard, smooth material with the dimensions shown in Figure 7. Dimensions in millimetres
Key A front view B top view C side view D 3D view Figure 7 — Shape assessment probe
4.6 Test probes for limb entrapment
+01,
Probes made from plastic or other hard, smooth material of diameters 25 mm and 45 mm with a −01, 0 conical end that can be mounted on a force-measuring device, see Figure 8.
Key Probe type 25 mm probe 45 mm probe
+01, 25 mm Diameter ØA 45 mm −01,
Figure 8 — Test probes with conical end
SIST EN 12221:2026 EN 12221:2026 (E)
4.7 Test probes for head entrapment
4.7.1 Small head probe
Probe made of hard and smooth material with dimensions as shown in Figure 9. Dimensions in millimetres
Key 1 handle Figure 9 — Small head probe
4.7.2 Large head probe
Cylindrical probe made of hard and smooth material with dimensions as shown in Figure 10. Dimensions in millimetres
Key 1 handle Figure 10 — Large head probe
SIST EN 12221:2026 EN 12221:2026 (E)
4.7.3 Template for partially bound and V shaped openings
Probe made of hard and smooth material with dimensions as shown in Figure 11. Dimensions in millimetres
a) Front view b) Side view Key A “A” portion of the probe B “B” portion of the probe B1 Shoulder section, either 25 mm or 45 mm dimension is acceptable Figure 11 — Template for partially bound and V shaped openings
4.8 Test floor for floor standing units
The test floor shall be horizontal, rigid, flat and smooth.
4.9 Test wall for wall mounted changing units
The test wall shall be vertical, rigid, flat and smooth.
4.10 Test base for bath mounted units
Test base for bath mounted units represents the upper bath wall section made of hard and smooth material with dimensions in accordance with Figure 12. The profiles shall be fixed parallel to the distance equal to the minimum bath dimension recommended by the manufacturer.
SIST EN 12221:2026 EN 12221:2026 (E) Dimensions in millimetres
Key 1 inside 2 outside Figure 12 — Cross section; bath test base, right side
4.11 Stops
Stops to prevent the article from sliding but not tilting, not higher than 12 mm except in cases where the design of the item necessitates the use of higher stops, in which case the lowest that will prevent the item from moving shall be used.
4.12 Test beam
Test beam with a width of 80 mm, a length of 1 100 mm and a mass of 1,75 kg ± 0,03 kg. The test beam shall have holes with a diameter of 8 (+ 0,2/0) mm, drilled through its 80 mm wide face and symmetrically placed about its centre point.
There shall be pairs of holes with distances between the centre points of the two holes equal to: 372 mm, 492mm, 642 mm. An additional hole is required at the centre point of the test beam. NOTE The distances between the centre points of the pair of holes are equal to the minimum length and width specified in 8.2.1, minus 8 mm, in such a way that the distance between the furthest points of two holes is equal to the minimum length and width specified in 8.2.1.
4.13 Measuring rod for test beam
Measuring rod of 8 (−0,2/0) mm diameter with an adjustable collar and its lower end hemispherical. The total mass of one measuring rod and collar shall be (0,12 ± 0,01) kg.
4.14 Side impactor
A pendulum with a cylindrical head made of steel (Figure 13). The head of the pendulum shall be surrounded by a 10 mm thick layer of rubber of hardness (77 ± 5) Shore A in accordance with ISO 48-4:2018. The total mass shall be 2 kg.
SIST EN 12221:2026 EN 12221:2026 (E) Dimensions in millimetres
Key 1 pivot point 2 centre of gravity 3 rubber (77 ± 5) Shore A Figure 13 — Side impactor
4.15 Loading pad
A rigid cylindrical object, 100 mm in diameter, having a smooth hard surface and rounded edge, with radius of 12 mm.
4.16 Aluminium oxide abrasive paper
Aluminium oxide abrasive paper, 80 grit (P80).
4.17 Test rig
A rigid flat surface made of any suitable material, having dimensions greater than the dimensions of the changing pad to be tested, with at least one rigid barrier adjustable to the height recommended in the manufacturer's instructions.
SIST EN 12221:2026 EN 12221:2026 (E)
5 General requirements and test conditions
5.1 Product conditioning
The sample for testing shall be stored in indoor ambient conditions for at least 24 h prior to testing. Before testing, any fabrics used shall be cleaned or washed and dried twice in accordance with the manufacturer's instructions.
5.2 Test conditions
The tests shall be carried out in ambient conditions of (21 ± 6) °C. The product shall be tested as delivered. The product shall be assembled according to the instructions supplied with the unit. If the product can be assembled or combined in different ways, the most onerous combinations shall be used for each test. All fittings shall be tightened in accordance with the manufacturer's instructions and shall not be retightened throughout the test procedure.
5.3 Application of forces
The tests are described in terms of the application of forces. Masses can however be used. The relationship 10 N = 1 kg may be used for this purpose.
The forces in the static load tests shall be applied sufficiently slowly to ensure that negligible dynamic force is applied.
The forces in the durability tests shall be applied at a rate to ensure that excessive heating does not occur. Unless otherwise specified, the test forces may be applied by any suitable device which does not adversely affect the results.
5.4 Tolerances of the test equipment
Unless otherwise stated, the tolerance of the test equipment shall be:
- Forces: ±5 % of the nominal force;
- Masses: ±0,5 % of the nominal mass;
- Dimensions: ±1 mm;
- Angles: ±0,5°;
- Time: ±1 s;
- Positioning of loading pads: ±5 mm;
SIST EN 12221:2026 EN 12221:2026 (E)
5.5 Determination of protected volume (see A.4.1)
The protected volume is the space contained within 550 mm above the changing area and within 200 mm around the changing area measured horizontally from the inner side of the barriers at their base or from the upper edge of the changing area on a side where there is no barrier (see Figure 14a, Figure 14b and Figure 14c).
Dimensions in millimetres
a) Top view
b) Front view
SIST EN 12221:2026 EN 12221:2026 (E)
c) Side view Figure 14 — Protected volume
5.6 Order of tests
Unless otherwise stated in the test methods, the tests shall be carried out on the same product in the order listed in this standard.
6 Chemical hazards (see A.2)
6.1 General
If testing is required, a separate unconditioned sample shall be used for the tests in Clause 6. NOTE A list of relevant EU legislation can be found in the Bibliography.
6.2 Migration of certain elements
The migration of elements from materials on surfaces within the protected volume shall not exceed the limits defined in EN 71-3:2019+A2:2024.
When testing is performed, the method specified in EN 71-3:2019+A2:2024 shall be used.
6.3 Formaldehyde
Textile components within the protected volume shall not contain free and hydrolysed formaldehyde in excess of 30 mg/kg.
When testing is performed, the method specified in EN ISO 14184-1:2011 shall be used.
7 Thermal hazards (see A.3)
The sample shall be prepared in accordance with Clause 5.4.1.1 and 5.4.1.2 of EN 71-2:2020+A1:2025. Textiles, coated textile supports, and plastic coverings should not have surface flash when tested in accordance with EN 71-2:2020+A1:2025, 5.5. Textiles, coated textile supports, and plastic coverings
SIST EN 12221:2026 EN 12221:2026 (E) showing no sudden area of flame over the area remote from the test flame are considered to meet this requirement.
Textiles, coated textile supports, and plastic coverings should have a maximum rate of spread of flame of 50 mm/s when tested in accordance with EN 71-2:2020+A1:2025, 5.4.2, 5.4.3, 5.4.4, 5.4.5 and 5.4.6. The term “soft-filled toys” in the referenced clauses shall be substituted by “the childcare article under test”.
A separate sample, conditioned according to 5.1, can be used for these tests.
8 Mechanical hazards
8.1 Changing pads
Changing pads intended to be used on a defined list of changing unit(s) shall be tested in conjunction with the compatible changing unit(s).
For changing pads intended to be used on non-specified changing units, the applicable clauses of Clause 8 are 8.3, 8.4, 8.5, 8.7, 8.8, 8.9, 8.10.
For changing pads not intended to be used on any changing unit nor on an elevated surface, the applicable clauses of Clause 8 are 8.3, 8.4, 8.7, 8.8, 8.9, 8.10.
8.2 Hazards due to inadequate size (see A.4.2)
8.2.1 Requirements
The minimum dimensions of the changing area, when measured in accordance with 8.2.2 shall be according to Table 1:
Table 1 — Minimum dimensions of the changing area Changing unit type Width Length Changing unit 380 mm 650 mm Changing unit accessory 380 mm 500 mm The length of the changing area is the intended longitudinal position of the child on the unit. The width of the changing area is the measurement perpendicular to the length.
8.2.2 Test methods
8.2.3 Measurement of width
Position the changing unit on the relevant base (see 4.8, 4.9, 4.10) or attach the changing unit accessory to the product it is intended to be used with.
Measure the width in the middle of the flat area; if the width is greater than the minimum required, then the width requirement is met.
If not, place the test beam (see 4.12) in the middle and across the width of the changing area (as shown in Figure 15). Place a measurement rod (see 4.13) through the central hole of the test beam so that it rests on the top of the changing surface. h is the distance that the measuring rod protrudes below the underside of the test beam. Place two measuring rods, adjusted to extend one third of h below the underside of the test beam, through the relevant holes in the test beam.
If the collars on these two measuring rods rest on the upper surface of the test beam and the rods are within the space enclosed by the barriers, then the width requirement is met.
SIST EN 12221:2026 EN 12221:2026 (E)
Key 1 minimum width Figure 15 — Method of measurement of the width
8.2.4 Measurement of the length
Measure the length in the middle of the flat area; if the length is greater than the minimum required, the length requirement is met.
If not, measure the length of the changing area in the middle of the flat area by the same procedure as specified for the measurement of width in 8.2.3, except that the relevant holes for the minimum length shall be used.
If the vertical projections of the rods are within the area of the changing units and the collars rest on the upper surface of the test beam then the length requirement is met.
8.3 Entrapment hazards
8.3.1 Entrapment of fingers (see A.4.3.1)
8.3.1.1 Requirements
When tested in accordance with 8.3.1.2, there shall be no completely bounded openings in rigid materials, within the protected volume, that let the 7 mm probe (see 4.5.1) go through unless the depth of penetration is less than 10 mm or unless the shape assessment probe (see 4.5.3) enters. When tested in accordance with 8.3.1.2, there shall be no openings in mesh, within the protected volume, that allow the test probe for mesh (see 4.5.2) to penetrate to the 7 mm diameter section. The test shall be carried out with the product in any intended position of use.
8.3.1.2 Test methods
Check whether the 7 mm probe (see 4.5.1), with an applied force of up to 30 N, enters 10 mm or more into any accessible completely bounded opening in any possible orientation. If the 7 mm probe enters 10 mm or more, then the shape assessment probe (see 4.5.3) shall also enter 10 mm or more with an applied force of up to 5 N.
Check whether the test probe for mesh (see 4.5.2), with an applied force of up to 30 N, penetrates accessible openings in mesh up to the 7 mm diameter section.
SIST EN 12221:2026 EN 12221:2026 (E)
8.3.2 Entrapment of limbs
8.3.2.1 Requirements
When tested in accordance with 8.3.2.2, there shall be no gaps and openings in rigid materials, within the protected volume, that let the 25 mm probe (see 4.6) go through unless the 45 mm probe (see 4.6) enters.
8.3.2.2 Test methods
Check whether the 25 mm probe (see 4.6), with an applied force of up to 30 N, enters with the full diameter into any accessible gap or opening in any possible orientation. If the 25 mm probe enters, then the 45 mm probe (see 4.6) shall also enter with the full diameter with an applied force of up to 5 N.
8.3.3 Entrapment of head, neck and torso (see A.4.3.2)
8.3.3.1 Requirements
When tested in accordance with 8.3.3.2.1, openings with the lowest point higher than 600 mm above the floor that allow the passage of the small head probe (4.7.1), shall also allow the passage of the large head probe (4.7.2).
Partially bound, V and irregular shaped openings with the lowest point higher than 200 mm above the floor that allow the passage of small head probe shall be constructed so that:
a) portion B of the template (see 4.7.3) does not enter the opening when tested in accordance with 8.3.3.2.2, see Figure 16 and Figure 17; or b) if a) fails, the apex of portion A of the template (see 4.7.3) contacts the base of the opening when tested in accordance with 8.3.3.2.2, see Figure 18.
8.3.3.2 Test methods
8.3.3.2.1 Head first openings Push the small head probe (see 4.7.1) with an applied force of up to 30 N into the opening. If the small head probe passes completely through the opening, then the large head probe (see 4.7.2) shall pass completely through the opening with a force of up to 5 N. The probes shall be inserted along the longitudinal axis of the probe. If openings contain V or irregular shaped openings, these shall be assessed in accordance with 8.3.3.2.2.
...