SIST EN 61199:2011/A1:2013
(Amendment)Single-capped fluorescent lamps - Safety specifications
Single-capped fluorescent lamps - Safety specifications
This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1.
It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard.
NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901.
It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347-2-3 or IEC 61347-2-8 with a starting device complying with IEC 60155 (if applicable) and in a luminaire complying with IEC 60598-1.
Einseitig gesockelte Leuchtstofflampen – Sicherheitsanforderungen
Lampes à fluorescence à culot unique - Specifications de sécurité
Fluorescenčne sijalke z enim vznožkom - Varnostne specifikacije
Ta mednarodni standard določa varnostne zahteve za fluorescenčne sijalke z enim vznožkom za splošne potrebe razsvetljave vseh skupin, ki imajo vznožke v skladu s preglednico 1. Prav tako določa metodo, ki jo mora uporabiti proizvajalec, da izkaže skladnost z zahtevami tega standarda na podlagi presoje celotne proizvodnje v povezavi s svojimi zapisi o preskusih končnih izdelkov. Ta metoda se lahko uporablja tudi za certifikacijo. Podrobnosti o šaržnem preskusnem postopku, ki se lahko uporablja za omejeno oceno serij, so prav tako podane v tem standardu. OPOMBA: Skladnost s tem standardom zadeva samo varnostne kriterije in ne upošteva delovanja fluorescenčnih sijalk z enim vznožkom za splošne potrebe razsvetljave z upoštevanjem svetlobnega toka, barve, značilnosti zagona in delovanja. Te informacije bralci najdejo v IEC 60901. Lahko se pričakuje, da bodo sijalke, ki so v skladu s tem standardom, delovale varno pri napajalni napetosti med 90 % in 110 % ocenjene napajalne napetosti uporabljenega balasta, kadar bodo delovale z balastom, ki je v skladu z IEC 61347-2-3 ali IEC 61347-2-8, z zagonsko napravo, ki je v skladu z IEC 60155 (če velja) in v sijalki, ki je v skladu z IEC 60598-1.
General Information
- Status
- Published
- Publication Date
- 11-Jun-2013
- Technical Committee
- IESV - Lamps and related equipment
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 05-Jun-2013
- Due Date
- 10-Aug-2013
- Completion Date
- 12-Jun-2013
Relations
- Effective Date
- 20-Dec-2011
Overview
EN 61199:2011/A1:2013 is the CENELEC amendment to the European version of IEC 61199:2011/A1:2012 and specifies safety requirements for single‑capped fluorescent lamps. The amendment (A1) clarifies electrical safety limits, introduces photobiological safety alignment with IEC 62471, and adjusts safety tables (notably Table F.1) to correctly reflect differences between magnetic and electronic ballast operation. It is intended for general lighting service (GLS) lamps and supports compliance with the Low Voltage Directive (LVD).
Key Topics and Requirements
- Electrical safety limits
- Clarifies the meaning and applicability of the table entries for pre‑heat current, discharge current, and SoS (sum of squares) safety limit.
- Emphasises that the pre‑heat current safety limit applies to magnetic operation with internal or external starters (abnormal operation). Electronic ballasts can exceed this limit without indicating a safety risk when their control gear prevents base overheating (see Annex H of IEC 61199).
- Photobiological safety
- Incorporates horizontal requirements from IEC 62471 and IEC/TR 62471‑2 for photobiological assessment of lamps.
- Defines GLS lamp measurement at an equivalent 500 lx distance and states GLS lamps will typically be below the marking thresholds for blue‑light and infrared (IR) hazards (risk group 1 for blue light; risk group 0 for IR).
- Interchangeability and operation modes
- Table F.1 header revised to explicitly identify operation with starterless (electronic) and starter (magnetic) configurations to avoid misinterpretation of limits.
- Regulatory alignment
- Confirms that the standard covers the Principle Elements of LVD (2006/95/EC) and notes potential patent considerations.
Applications - Who Uses This Standard
- Lamp manufacturers - design and safety verification of single‑capped fluorescent lamps.
- Ballast and control‑gear designers - ensure electronic/magnetic ballast interactions meet safety limits (pre‑heat, discharge, SoS).
- Test laboratories & certification bodies - product testing, photobiological assessment, and conformity assessment.
- Safety engineers, procurement/specification teams, regulators - select compliant lighting components and verify LVD conformity.
- Lighting designers & installers - understand interchangeability constraints and safe usage conditions.
Related Standards
- IEC 61199 (base international standard)
- IEC 62471 & IEC/TR 62471‑2 (photobiological safety guidance)
- Low Voltage Directive (2006/95/EC)
- CENELEC adoption and national standardization references
Keywords: EN 61199:2011/A1:2013, single‑capped fluorescent lamps, safety specifications, photobiological safety, IEC 62471, electronic ballast, magnetic ballast, pre‑heat current, discharge current, lamp safety.
Frequently Asked Questions
SIST EN 61199:2011/A1:2013 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Single-capped fluorescent lamps - Safety specifications". This standard covers: This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901. It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347-2-3 or IEC 61347-2-8 with a starting device complying with IEC 60155 (if applicable) and in a luminaire complying with IEC 60598-1.
This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901. It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347-2-3 or IEC 61347-2-8 with a starting device complying with IEC 60155 (if applicable) and in a luminaire complying with IEC 60598-1.
SIST EN 61199:2011/A1:2013 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61199:2011/A1:2013 has the following relationships with other standards: It is inter standard links to SIST EN 61199:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 61199:2011/A1:2013 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 61199:2011/A1:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2013
)OXRUHVFHQþQHVLMDONH]HQLPY]QRåNRP9DUQRVWQHVSHFLILNDFLMH
Single-capped fluorescent lamps - Safety specifications
Einseitig gesockelte Leuchtstofflampen – Sicherheitsanforderungen
Lampes à fluorescence à culot unique - Specifications de sécurité
Ta slovenski standard je istoveten z: EN 61199:2011/A1:2013
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61199/A1
NORME EUROPÉENNE
February 2013
EUROPÄISCHE NORM
ICS 29.140.30
English version
Single-capped fluorescent lamps -
Safety specifications
(IEC 61199:2011/A1:2012)
Lampes à fluorescence à culot unique - Einseitig gesockelte Leuchtstofflampen -
Specifications de sécurité Sicherheitsanforderungen
(CEI 61199:2011/A1:2012) (IEC 61199:2011/A1:2012)
This amendment A1 modifies the European Standard EN 61199:2011; it was approved by CENELEC on 2012-
11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61199:2011/A1:2013 E
Foreword
The text of document 34A/1538/CDV, future edition 1 of IEC 61199:2011/A1, prepared by SC 34A,
"Lamps", of IEC TC 34, "Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 61199:2011/A1:2013.
The following dates are fixed:
(dop) 2013-08-22
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2015-11-01
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed
for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Endorsement notice
The text of the International Standard IEC 61199:2011/A1:2012 was approved by CENELEC as a
European Standard without any modification.
IEC 61199 ®
Edition 3.0 2012-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Single-capped fluorescent lamps – Safety specifications
Lampes à fluorescence à culot unique – Spécifications de sécurité
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX D
ICS 29.140.30 ISBN 978-2-83220-386-6
® Registered trademark of t
...