Workplace atmospheres - Part 1: Gas detectors - Performance requirements of detectors for toxic gases (IEC 62990-1:2019 + COR1:2019)

This part of IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications. This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present.
This document applies to two types of equipment:
- Type HM (Health Monitoring) ‘occupational exposure’ equipment: For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1.
- Type SM (Safety Monitoring) ‘general gas detection’ equipment: For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment. In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM. For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour.
This document is not applicable to equipment:
- with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
- used for the measurement of gases and vapours related to the risk of explosion;
- used for the measurement of oxygen; – used only in laboratories for analysis or measurement;
- used only for process measurement purposes;
- used in the domestic environment;
- used in environmental air pollution monitoring;
- used for open-path (line of sight) area gas measurement;
- used for ventilation control in car parks or tunnels.

Arbeitsplatzatmosphäre - Teil 1: Gasmessgeräte - Anforderungen an das Betriebsverhalten von Geräten für die Messung toxischer Gase (IEC 62990-1:2019 + COR1:2019)

Atmosphères des lieux de travail - Partie 1: Détecteurs de gaz - Exigences d'aptitude à la fonction des détecteurs de gaz toxiques (IEC 62990-1:2019 + COR1:2019)

IEC 62990-1:2019 spécifie les exigences générales pour la conception, la fonction et l’aptitude au fonctionnement, et décrit les méthodes d’essai qui s’appliquent aux matériels portables, transportables et fixes pour la détection et le mesurage de la concentration des gaz et des vapeurs toxiques dans les atmosphères des lieux de travail et d’autres applications industrielles et commerciales.
Le présent document s’applique aux matériels à fonctionnement continu dont l’objectif principal est de donner une indication, une alarme et/ou une autre fonction de sortie, le but étant de signaler la présence d’un gaz ou d’une vapeur toxique dans l’atmosphère et, dans certains cas, de déclencher une ou des actions protectrices manuelles ou automatiques. Il s’applique aux matériels dont le capteur produit un signal électrique en présence d’un gaz.
Le présent document s’applique à deux types de matériels:
• Les matériels “d'exposition professionnelle” de type HM (surveillance de la santé):
Pour le mesurage de l’exposition professionnelle, les exigences d’aptitude à la fonction ciblent l'incertitude de mesure des concentrations de gaz dans l’étendue d’application des valeurs limites d’exposition professionnelle (OELV – Occupational Exposure Limit Values). La limite supérieure de mesure est définie par le constructeur conformément à 4.2.1.
• Les matériels de “détection générale de gaz” de type SM (surveillance de la sécurité):
Pour les applications de détection générale de gaz (par exemple, avertissement de sécurité, détection de fuite), les exigences d’aptitude à la fonction ciblent la signalisation d’alarme. La limite supérieure de mesure est définie par le constructeur en fonction de l’utilisation prévue du matériel.
Généralement, les exigences d’exactitude sont plus strictes pour les matériels de type HM que pour les matériels de type SM. Les mêmes matériels peuvent satisfaire aux exigences applicables aux deux types HM et SM.
Pour les matériels qui permettent de détecter la présence de plusieurs gaz, le présent document s’applique uniquement pour la détection des gaz ou vapeurs toxiques.
Le présent document ne s’applique pas aux matériels:
- comportant des échantillonneurs et des concentrateurs tels que des sorbants ou une bande de papier qui présentent une indication irréversible;
- utilisés pour le mesurage des gaz et vapeurs liés au risque d’explosion;
- utilisés pour le mesurage de l’oxygène;
- utilisés uniquement en laboratoires pour l’analyse ou le mesurage;
- utilisés uniquement pour la mesure de processus;
- utilisés dans l’environnement domestique;
- utilisés dans la surveillance de la pollution atmosphérique;
- utilisés pour le mesurage des gaz avec emplacement à chemin ouvert (champ de vision);
- utilisés pour la commande de la ventilation dans les parcs de stationnement ou les tunnels.
Le contenu du corrigendum de décembre 2019 a été pris en considération dans cet exemplaire.

Zrak na delovnem mestu - 1. del: Detektorji plina - Zahteve za delovanje detektorjev strupenih plinov (IEC 62990-1:2019 + COR1:2019)

Ta del standarda IEC 62990 določa splošne zahteve za zasnovo, delovanje in zmogljivost ter opisuje preskusne metode, ki se uporabljajo za prenosno, premično in fiksno opremo za zaznavanje oziroma merjenje koncentracij strupenih plinov ali hlapov v zraku na delovnem mestu ter pri drugih industrijskih in komercialnih aplikacijah. Ta dokument se uporablja za neprekinjeno delujočo merilno opremo, katere primarni namen je izdati opozorilo, alarm in/ali drugo izhodno funkcijo, ki opozori na prisotnost strupenih plinov ali hlapov v ozračju in v nekaterih primerih tudi sproži samodejne ali ročne zaščitne ukrepe. Uporablja se za opremo, v kateri senzor ob prisotnosti plina ustvari električni signal.
Dokument se uporablja za dve vrsti opreme:
• Oprema za »poklicno izpostavljenost« vrste HM (Health Monitoring): za merjenje poklicne izpostavljenosti so zahteve za delovanje osredotočene na negotovost merjenja koncentracij plinov v območju mejnih vrednosti poklicne izpostavljenosti (OELV). Zgornjo mejo meritev določi proizvajalec v skladu s točko 4.2.1.
• Oprema vrste SM (Safety Monitoring) za »splošno zaznavanje plina«: za splošno zaznavanje plina (npr. varnostno opozorilo, zaznavanje puščanja) so zahteve za delovanje osredotočene na alarmno signalizacijo. Zgornjo mejo meritev določi proizvajalec v skladu s predvideno uporabo opreme. Na splošno so zahteve glede natančnosti višje za opremo vrste HM kot za opremo vrste SM. Ista oprema lahko izpolnjuje zahteve za vrsto HM in vrsto SM. Pri opremi, ki se uporablja za zaznavanje prisotnosti več plinov, se ta dokument uporablja le za zaznavanje strupenih plinov ali hlapov.
Ta dokument se ne uporablja za opremo, ki se uporablja:
– z vzorčevalniki in koncentratorji, kot so sorbenti ali papirnati trakovi, ki imajo nepovratni prikaz;
– za merjenje plinov in hlapov v zvezi z nevarnostjo eksplozije;
– za merjenje kisika;
– le v laboratorijih za analize ali merjenje;
– samo za namene merilnega postopka;
– v domačem okolju;
– pri nadzoru onesnaženja zraka v okolju;
– za merjenje plina z odprto merilno potjo (linija pogleda);
– za nadzor prezračevanja v parkirnih hišah in predorih.

General Information

Status
Published
Public Enquiry End Date
27-Feb-2022
Publication Date
22-Nov-2022
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
18-Oct-2022
Due Date
23-Dec-2022
Completion Date
23-Nov-2022

Relations

Buy Standard

Standard
EN IEC 62990-1:2023 - BARVE
English language
64 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN IEC 62990-1:2022 - BARVE
English language
64 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 62990-1:2023
01-januar-2023
Nadomešča:
SIST EN 45544-1:2015
SIST EN 45544-2:2015
SIST EN 45544-3:2015
Zrak na delovnem mestu - 1. del: Detektorji plina - Zahteve za delovanje
detektorjev strupenih plinov (IEC 62990-1:2019 + COR1:2019)
Workplace atmospheres - Part 1: Gas detectors - Performance requirements of detectors
for toxic gases (IEC 62990-1:2019 + COR1:2019)
Arbeitsplatzatmosphäre - Teil 1: Gasmessgeräte - Anforderungen an das
Betriebsverhalten von Geräten für die Messung toxischer Gase (IEC 62990-1:2019 +
COR1:2019)
Atmosphères des lieux de travail - Partie 1: Détecteurs de gaz - Exigences d'aptitude à
la fonction des détecteurs de gaz toxiques (IEC 62990-1:2019 + COR1:2019)
Ta slovenski standard je istoveten z: EN IEC 62990-1:2022
ICS:
13.040.30 Kakovost zraka na delovnem Workplace atmospheres
mestu
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST EN IEC 62990-1:2023 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 62990-1:2023

---------------------- Page: 2 ----------------------
SIST EN IEC 62990-1:2023


EUROPEAN STANDARD EN IEC 62990-1

NORME EUROPÉENNE

EUROPÄISCHE NORM October 2022
ICS 29.260.20 Supersedes EN 45544-1:2015; EN 45544-3:2015;
EN 45544-2:2015
English Version
Workplace atmospheres - Part 1: Gas detectors - Performance
requirements of detectors for toxic gases
(IEC 62990-1:2019 + COR1:2019)
Atmosphères des lieux de travail - Partie 1: Détecteurs de Arbeitsplatzatmosphäre - Teil 1: Gasmessgeräte -
gaz - Exigences d'aptitude à la fonction des détecteurs de Anforderungen an das Betriebsverhalten von Geräten für
gaz toxiques die Messung toxischer Gase
(IEC 62990-1:2019 + COR1:2019) (IEC 62990-1:2019 + COR1:2019)
This European Standard was approved by CENELEC on 2022-08-17. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 62990-1:2022 E

---------------------- Page: 3 ----------------------
SIST EN IEC 62990-1:2023
EN IEC 62990-1:2022 (E)
European foreword
This document (EN IEC 62990-1:2022) consists of the text of IEC 62990-1:2019 and
IEC 62990-1:2019/COR1:2019 prepared by IEC/TC 31 “Equipment for explosive atmospheres” in cooperation
with ISO/TC 146 “Air quality, sub-committee 2: Workplace atmospheres”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2023-08-27
implemented at national level by publication of an
identical national standard or by endorsement
• latest date by which the national standards (dow) 2025-08-27
conflicting with this document have to be withdrawn
This document, together with EN IEC 62990-1/A11:2022, supersedes EN 45544-1:2015, EN 45544-2:2015
and EN 45544-3:2015.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 62990-1:2019 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60079-29-1 NOTE Harmonized as EN 60079-29-1
IEC 60079-29-2 NOTE Harmonized as EN 60079-29-2
IEC 60079-29-3 NOTE Harmonized as EN 60079-29-3
IEC 60079-29-4 NOTE Harmonized as EN 60079-29-4
ISO 6145-1 NOTE Harmonized as EN ISO 6145-1
ISO 6145-4 NOTE Harmonized as EN ISO 6145-4
ISO 6145-5 NOTE Harmonized as EN ISO 6145-5
ISO 6145-6 NOTE Harmonized as EN ISO 6145-6
ISO 6145-7 NOTE Harmonized as EN ISO 6145-7
ISO 6145-9 NOTE Harmonized as EN ISO 6145-9
ISO 6145-10 NOTE Harmonized as EN ISO 6145-10
ISO 20581 NOTE Harmonized as EN 482

2

---------------------- Page: 4 ----------------------
SIST EN IEC 62990-1:2023




IEC 62990-1


Edition 1.0 2019-06




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Workplace atmospheres –

Part 1: Gas detectors – Performance requirements of detectors for toxic gases




Atmosphères des lieux de travail –

Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs

de gaz toxiques















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.260.20 ISBN 978-2-8322-7080-6




Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

---------------------- Page: 5 ----------------------
SIST EN IEC 62990-1:2023
– 2 – IEC 62990-1:2019 © IEC 2019

CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 8
3 Terms and definitions . 8
4 General requirements . 16
4.1 Overview. 16
4.2 Design . 17
4.2.1 General . 17
4.2.2 Indicating devices . 17
4.2.3 Alarm signal . 19
4.2.4 Fault signals . 19
4.2.5 Adjustments . 20
4.2.6 Battery-powered equipment . 20
4.2.7 Gas detection transmitter for use with separate gas detection control
units . 20
4.2.8 Separate gas detection control units for use with gas detection
transmitter(s) . 21
4.2.9 Software-controlled equipment . 21
4.3 Labelling and marking . 22
4.4 Instruction manual . 23
5 Test methods . 25
5.1 General . 25
5.2 General requirements for tests . 26
5.2.1 Samples and sequence of tests . 26
5.2.2 Preparation of equipment before each test. 27
5.2.3 Mask for calibration and test . 28
5.3 Normal conditions for test . 28
5.3.1 General . 28
5.3.2 Test gas(es) . 28
5.3.3 Flow rate for test gases . 28
5.3.4 Power supply . 29
5.3.5 Temperature . 29
5.3.6 Pressure . 29
5.3.7 Humidity . 29
5.3.8 Acclimation time . 29
5.3.9 Orientation . 29
5.3.10 Communications options . 29
5.3.11 Gas detection equipment as part of systems . 30
5.4 Tests . 30
5.4.1 General . 30
5.4.2 Unpowered storage . 30
5.4.3 Measurement of deviations . 31
5.4.4 Mechanical tests . 31
5.4.5 Environmental tests . 33
5.4.6 Performance tests . 36
5.4.7 Electrical tests . 41

---------------------- Page: 6 ----------------------
SIST EN IEC 62990-1:2023
IEC 62990-1:2019 © IEC 2019 – 3 –
5.4.8 Stability . 44
5.4.9 Fault signal tests . 45
5.4.10 Software controlled equipment . 46
5.4.11 Protection against water . 46
6 Uncertainty of measurement and lower limit of measurement for type HM

equipment . 47
6.1 General . 47
6.2 Method of calculation of uncertainty of measurement . 47
6.2.1 Basic concept . 47
6.2.2 Sources of uncertainty . 48
6.2.3 Calculation of relative expanded uncertainty . 53
6.3 Method of calculation of lower limit of measurement . 54
6.4 Acceptance criteria . 55
6.4.1 Uncertainty of measurement . 55
6.4.2 Lower limit of measurement . 55
6.5 Relation between uncertainty and accuracy . 55
Annex A (normative) Gas specific performance requirements . 56
Annex B (informative) Determination of time of response and time of recovery . 57
B.1 Aspirated equipment . 57
B.1.1 Test rig . 57
B.1.2 Equipment without internal pump . 57
B.1.3 Equipment with internal pump . 57
B.2 Equipment that samples by diffusion . 58
B.2.1 Calibration mask method . 58
B.2.2 Diffusion or flow methods . 58
Bibliography . 60

Figure 1 – Relationship between indication range and measuring range . 14
Figure 2 – Warm-up time in clean air (typical) . 15
Figure 3 – Warm-up time in standard test gas (typical) . 15
Figure 4 – Example of zero uncertainty . 16
Figure B.1 – Schematic example of test rig for use with aspirated equipment . 58
Figure B.2 – Schematic example of test chamber for diffusion method . 59
Figure B.3 – Schematic example of test chamber for flow method . 59

Table 1 – Factors to be considered in the expanded uncertainty estimate . 48
Table A.1 – Gas specific performance requirements . 56

---------------------- Page: 7 ----------------------
SIST EN IEC 62990-1:2023
– 4 – IEC 62990-1:2019 © IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

WORKPLACE ATMOSPHERES –

Part 1: Gas detectors –
Performance requirements of detectors for toxic gases

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62990-1 has been prepared by Joint Working Group (JWG) 45 of
IEC technical committee 31: Equipment for explosive atmospheres in cooperation with
ISO technical committee 146: Air quality, sub-committee 2: Workplace atmospheres.
It is published as a dual logo standard.
The text of this International Standard is based on the following documents:
FDIS Report on voting
31/1463/FDIS 31/1480/RVD

Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.

---------------------- Page: 8 ----------------------
SIST EN IEC 62990-1:2023
IEC 62990-1:2019 © IEC 2019 – 5 –
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 62990 series, published under the general title Workplace
atmospheres, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of December 2019 have been included in this copy.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 9 ----------------------
SIST EN IEC 62990-1:2023
– 6 – IEC 62990-1:2019 © IEC 2019
INTRODUCTION
This part of IEC 62990 specifies general requirements for construction, testing and
performance of equipment intended to measure the concentration of toxic gas and vapour in
workplace atmospheres and other industrial and commercial applications. The performance
requirements are intended to apply under environmental conditions present at the site of
operation. However, because a wide range of environmental conditions are encountered in
practise, this document specifies requirements that have to be fulfilled by equipment when
tested under prescribed laboratory conditions.
This document applies to the following types of equipment: Health Monitoring (HM) and Safety
Monitoring (SM). For a given measurement task of Type HM equipment the range over which
the requirements must be met depends on the occupational exposure limit value. However, for
most toxic gases and vapours the occupational exposure limit values have not been
harmonized at the international level. Therefore, it was decided to use a reference value
instead of the occupational exposure limit value for the performance tests. The list of
reference values is given in Annex A. The reference values chosen are equal to or close to
the occupational exposure limit values used in different countries but are intended to be used
only for type testing equipment without any legal implications.
Electrical equipment used for the direct detection and direct concentration measurement of
toxic gases and vapours generate readings in clean air (nominally zero), which vary with
environmental conditions and time. This document therefore includes test methods and
requirements for acceptable variations in measured values at application of zero gas and of
defined test gases.
For gas detection equipment including additional function for detecting flammable gas and/or
oxygen, consideration should be given to the relevant standards.
General requirements for construction, testing and performance of gas detectors for
flammable gases and vapours are set out in IEC 60079-29-1, Explosive atmospheres –
Part 29-1: Gas detectors – Performance requirements of detectors for flammable gases.
General requirements for construction, testing and performance of open path detectors for
flammable gases are set out in IEC 60079-29-4, Explosive atmospheres – Part 29-4: Gas
detectors – Performance requirements of open path detectors for flammable gases.
Guidance for the selection, installation, use and maintenance of gas detecting equipment is
set out in IEC 60079-29-2: Explosive atmospheres – Part 29-2, Gas detectors – Selection,
installation, use and maintenance of detectors for flammable gases and oxygen.
Guidance for functional safety of fixed gas detection systems is set out in IEC 60079-29-3:
Explosive atmospheres – Part 29-3, Gas detectors – Guidance on functional safety of fixed
gas detection systems.

---------------------- Page: 10 ----------------------
SIST EN IEC 62990-1:2023
IEC 62990-1:2019 © IEC 2019 – 7 –
WORKPLACE ATMOSPHERES –

Part 1: Gas detectors –
Performance requirements of detectors for toxic gases



1 Scope
This part of IEC 62990 specifies general requirements for design, function and performance,
and describes the test methods that apply to portable, transportable, and fixed equipment for
the detection and concentration measurement of toxic gases and vapours in workplace
atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to
provide an indication, alarm and/or other output function the purpose of which is to indicate
the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate
automatic or manual protective action(s). It is applicable to equipment in which the sensor
generates an electrical signal when gas is present.
This document applies to two types of equipment:
• Type HM (Health Monitoring) ‘occupational exposure’ equipment:
For occupational exposure measurement, the performance requirements are focused on
uncertainty of measurement of gas concentrations in the region of Occupational Exposure
Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer
in accordance with 4.2.1.
• Type SM (Safety Monitoring) ‘general gas detection’ equipment:
For general gas detection applications (e.g. safety warning, leak detection), the
performance requirements are focused on alarm signalling. The upper limit of
measurement will be defined by the manufacturer according to the intended use of the
equipment.
In general, the requirements for accuracy will be higher for Type HM equipment than for Type
SM equipment. The same equipment may meet the requirements of both Type HM and Type
SM.
For equipment used for sensing the presence of multiple gases this document applies only to
the detection of toxic gas or vapour.
This document is not applicable to equipment:
– with samplers and concentrators such as sorbents or paper tape having an irreversible
indication;
– used for the measurement of gases and vapours related to the risk of explosion;
– used for the measurement of oxygen;
– used only in laboratories for analysis or measurement;
– used only for process measurement purposes;
– used in the domestic environment;
– used in environmental air pollution monitoring;
– used for open-path (line of sight) area gas measurement;
– used for ventilation control in car parks or tunnels.

---------------------- Page: 11 ----------------------
SIST EN IEC 62990-1:2023
– 8 – IEC 62990-1:2019 © IEC 2019
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal)
IEC 60079-0, Explosive atmospheres – Part 0: Equipment – General requirements
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 61000-4-29, Electromagnetic compatibility (EMC) – Part 4-29: Testing and measurement
techniques – Voltage dips, short interruptions and voltage variations on d.c. input power port
immunity tests
IEC 61000-6-3, Electromagnetic compatibility (EMC) – Part 6-3: Generic standards –
Emission standard for residential, commercial and light-industrial environments
IEC 61000-6-4, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards –
Emission standard for industrial environments
IEC 61326-1, Electrical equipment for measurement, control and laboratory use – EMC
requirements – Part 1: General requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
gas properties
3.1.1
ambient air
normal atmosphere surrounding the equipment
3.1.2
clean air
air that is free of gases or vapours which the sensor is sensitive to or which influence the
performance of the sensor
3.1.3
occupational exposure limit value
OELV
limit of the time-weighted average of the concentration of a chemical agent in the air within
the breathing zone of a worker in relation to a specified reference period
Note 1 to entry: The term “limit value” is often used as a synonym for “occupational exposure limit value”, but the
term “occupational exposure limit value” is preferred because there is more than one limit value (e.g., biological
limit value and occupational exposure limit value).

---------------------- Page: 12 ----------------------
SIST EN IEC 62990-1:2023
IEC 62990-1:2019 © IEC 2019 – 9 –
Note 2 to entry: Occupational exposure limit values (OELVs) are often set for reference periods of 8 h, but can
also be set for shorter periods or concentration excursions.
[SOURCE: ISO 18158:2016, 2.1.5.4, modified (Note 2 to entry is shortened)]
3.1.4
reference value
value used as the basis to specify requirements such as measuring
range, resolution and alarm set point
Note 1 to entry: The term reference value is used in this document because for most toxic gases and vapours the
occu
...

SLOVENSKI STANDARD
oSIST prEN IEC 62990-1:2022
01-februar-2022
Zrak na delovnem mestu - 1. del: Detektorji plina - Zahteve za delovanje
detektorjev strupenih plinov
Workplace Atmospheres - Part 1: Gas detectors - Performance requirements of
detectors for toxic gases
Atmosphères des lieux de travail - Partie 1: Détecteurs de gaz - Exigences d'aptitude à
la fonction des détecteurs de gaz toxiques
Ta slovenski standard je istoveten z: prEN IEC 62990-1
ICS:
13.040.30 Kakovost zraka na delovnem Workplace atmospheres
mestu
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
oSIST prEN IEC 62990-1:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 62990-1:2022

---------------------- Page: 2 ----------------------
oSIST prEN IEC 62990-1:2022


EUROPEAN STANDARD DRAFT
prEN IEC 62990-1
NORME EUROPÉENNE

EUROPÄISCHE NORM

December 2021
ICS 29.260.20

English Version
Workplace Atmospheres - Part 1: Gas detectors - Performance
requirements of detectors for toxic gases
(IEC 62990-1:2019 + COR1:2019)
Atmosphères des lieux de travail - Partie 1: Détecteurs de To be completed
gaz - Exigences d'aptitude à la fonction des détecteurs de (IEC 62990-1:2019 + COR1:2019)
gaz toxiques
(IEC 62990-1:2019 + COR1:2019)
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2022-03-04.

The text of this draft consists of the text of IEC 62990-1:2019 (31/1463/FDIS) + COR1:2019.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 71712 Ref. No. prEN IEC 62990-1 E

---------------------- Page: 3 ----------------------
oSIST prEN IEC 62990-1:2022
prEN IEC 62990-1:2021 (E)
European foreword
This document (prEN IEC 62990-1:2021) consists of the text of IEC 62990-1:2019 and
IEC 62990-1:2019/COR1:2019 prepared by IEC/TC 31 “Equipment for explosive atmospheres” in cooperation
with ISO/TC 146 “Air quality, sub-committee 2: Workplace atmospheres”.
This document is currently submitted to the Enquiry.
The following dates are proposed:
• latest date by which the existence of this document (doa) dor + 6 months
has to be announced at national level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of an
identical national standard or by endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to be withdrawn (to be confirmed or
modified when voting)

2

---------------------- Page: 4 ----------------------
oSIST prEN IEC 62990-1:2022




IEC 62990-1


Edition 1.0 2019-06




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Workplace atmospheres –

Part 1: Gas detectors – Performance requirements of detectors for toxic gases




Atmosphères des lieux de travail –

Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs

de gaz toxiques















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 29.260.20 ISBN 978-2-8322-7080-6




Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

---------------------- Page: 5 ----------------------
oSIST prEN IEC 62990-1:2022
– 2 – IEC 62990-1:2019 © IEC 2019

CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 8
3 Terms and definitions . 8
4 General requirements . 16
4.1 Overview. 16
4.2 Design . 17
4.2.1 General . 17
4.2.2 Indicating devices . 17
4.2.3 Alarm signal . 19
4.2.4 Fault signals . 19
4.2.5 Adjustments . 20
4.2.6 Battery-powered equipment . 20
4.2.7 Gas detection transmitter for use with separate gas detection control
units . 20
4.2.8 Separate gas detection control units for use with gas detection
transmitter(s) . 21
4.2.9 Software-controlled equipment . 21
4.3 Labelling and marking . 22
4.4 Instruction manual . 23
5 Test methods . 25
5.1 General . 25
5.2 General requirements for tests . 26
5.2.1 Samples and sequence of tests . 26
5.2.2 Preparation of equipment before each test. 27
5.2.3 Mask for calibration and test . 28
5.3 Normal conditions for test . 28
5.3.1 General . 28
5.3.2 Test gas(es) . 28
5.3.3 Flow rate for test gases . 28
5.3.4 Power supply . 29
5.3.5 Temperature . 29
5.3.6 Pressure . 29
5.3.7 Humidity . 29
5.3.8 Acclimation time . 29
5.3.9 Orientation . 29
5.3.10 Communications options . 29
5.3.11 Gas detection equipment as part of systems . 30
5.4 Tests . 30
5.4.1 General . 30
5.4.2 Unpowered storage . 30
5.4.3 Measurement of deviations . 31
5.4.4 Mechanical tests . 31
5.4.5 Environmental tests . 33
5.4.6 Performance tests . 36
5.4.7 Electrical tests . 41

---------------------- Page: 6 ----------------------
oSIST prEN IEC 62990-1:2022
IEC 62990-1:2019 © IEC 2019 – 3 –
5.4.8 Stability . 44
5.4.9 Fault signal tests . 45
5.4.10 Software controlled equipment . 46
5.4.11 Protection against water . 46
6 Uncertainty of measurement and lower limit of measurement for type HM

equipment . 47
6.1 General . 47
6.2 Method of calculation of uncertainty of measurement . 47
6.2.1 Basic concept . 47
6.2.2 Sources of uncertainty . 48
6.2.3 Calculation of relative expanded uncertainty . 53
6.3 Method of calculation of lower limit of measurement . 54
6.4 Acceptance criteria . 55
6.4.1 Uncertainty of measurement . 55
6.4.2 Lower limit of measurement . 55
6.5 Relation between uncertainty and accuracy . 55
Annex A (normative) Gas specific performance requirements . 56
Annex B (informative) Determination of time of response and time of recovery . 57
B.1 Aspirated equipment . 57
B.1.1 Test rig . 57
B.1.2 Equipment without internal pump . 57
B.1.3 Equipment with internal pump . 57
B.2 Equipment that samples by diffusion . 58
B.2.1 Calibration mask method . 58
B.2.2 Diffusion or flow methods . 58
Bibliography . 60

Figure 1 – Relationship between indication range and measuring range . 14
Figure 2 – Warm-up time in clean air (typical) . 15
Figure 3 – Warm-up time in standard test gas (typical) . 15
Figure 4 – Example of zero uncertainty . 16
Figure B.1 – Schematic example of test rig for use with aspirated equipment . 58
Figure B.2 – Schematic example of test chamber for diffusion method . 59
Figure B.3 – Schematic example of test chamber for flow method . 59

Table 1 – Factors to be considered in the expanded uncertainty estimate . 48
Table A.1 – Gas specific performance requirements . 56

---------------------- Page: 7 ----------------------
oSIST prEN IEC 62990-1:2022
– 4 – IEC 62990-1:2019 © IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

WORKPLACE ATMOSPHERES –

Part 1: Gas detectors –
Performance requirements of detectors for toxic gases

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62990-1 has been prepared by Joint Working Group (JWG) 45 of
IEC technical committee 31: Equipment for explosive atmospheres in cooperation with
ISO technical committee 146: Air quality, sub-committee 2: Workplace atmospheres.
It is published as a dual logo standard.
The text of this International Standard is based on the following documents:
FDIS Report on voting
31/1463/FDIS 31/1480/RVD

Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.

---------------------- Page: 8 ----------------------
oSIST prEN IEC 62990-1:2022
IEC 62990-1:2019 © IEC 2019 – 5 –
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 62990 series, published under the general title Workplace
atmospheres, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of December 2019 have been included in this copy.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 9 ----------------------
oSIST prEN IEC 62990-1:2022
– 6 – IEC 62990-1:2019 © IEC 2019
INTRODUCTION
This part of IEC 62990 specifies general requirements for construction, testing and
performance of equipment intended to measure the concentration of toxic gas and vapour in
workplace atmospheres and other industrial and commercial applications. The performance
requirements are intended to apply under environmental conditions present at the site of
operation. However, because a wide range of environmental conditions are encountered in
practise, this document specifies requirements that have to be fulfilled by equipment when
tested under prescribed laboratory conditions.
This document applies to the following types of equipment: Health Monitoring (HM) and Safety
Monitoring (SM). For a given measurement task of Type HM equipment the range over which
the requirements must be met depends on the occupational exposure limit value. However, for
most toxic gases and vapours the occupational exposure limit values have not been
harmonized at the international level. Therefore, it was decided to use a reference value
instead of the occupational exposure limit value for the performance tests. The list of
reference values is given in Annex A. The reference values chosen are equal to or close to
the occupational exposure limit values used in different countries but are intended to be used
only for type testing equipment without any legal implications.
Electrical equipment used for the direct detection and direct concentration measurement of
toxic gases and vapours generate readings in clean air (nominally zero), which vary with
environmental conditions and time. This document therefore includes test methods and
requirements for acceptable variations in measured values at application of zero gas and of
defined test gases.
For gas detection equipment including additional function for detecting flammable gas and/or
oxygen, consideration should be given to the relevant standards.
General requirements for construction, testing and performance of gas detectors for
flammable gases and vapours are set out in IEC 60079-29-1, Explosive atmospheres –
Part 29-1: Gas detectors – Performance requirements of detectors for flammable gases.
General requirements for construction, testing and performance of open path detectors for
flammable gases are set out in IEC 60079-29-4, Explosive atmospheres – Part 29-4: Gas
detectors – Performance requirements of open path detectors for flammable gases.
Guidance for the selection, installation, use and maintenance of gas detecting equipment is
set out in IEC 60079-29-2: Explosive atmospheres – Part 29-2, Gas detectors – Selection,
installation, use and maintenance of detectors for flammable gases and oxygen.
Guidance for functional safety of fixed gas detection systems is set out in IEC 60079-29-3:
Explosive atmospheres – Part 29-3, Gas detectors – Guidance on functional safety of fixed
gas detection systems.

---------------------- Page: 10 ----------------------
oSIST prEN IEC 62990-1:2022
IEC 62990-1:2019 © IEC 2019 – 7 –
WORKPLACE ATMOSPHERES –

Part 1: Gas detectors –
Performance requirements of detectors for toxic gases



1 Scope
This part of IEC 62990 specifies general requirements for design, function and performance,
and describes the test methods that apply to portable, transportable, and fixed equipment for
the detection and concentration measurement of toxic gases and vapours in workplace
atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to
provide an indication, alarm and/or other output function the purpose of which is to indicate
the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate
automatic or manual protective action(s). It is applicable to equipment in which the sensor
generates an electrical signal when gas is present.
This document applies to two types of equipment:
• Type HM (Health Monitoring) ‘occupational exposure’ equipment:
For occupational exposure measurement, the performance requirements are focused on
uncertainty of measurement of gas concentrations in the region of Occupational Exposure
Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer
in accordance with 4.2.1.
• Type SM (Safety Monitoring) ‘general gas detection’ equipment:
For general gas detection applications (e.g. safety warning, leak detection), the
performance requirements are focused on alarm signalling. The upper limit of
measurement will be defined by the manufacturer according to the intended use of the
equipment.
In general, the requirements for accuracy will be higher for Type HM equipment than for Type
SM equipment. The same equipment may meet the requirements of both Type HM and Type
SM.
For equipment used for sensing the presence of multiple gases this document applies only to
the detection of toxic gas or vapour.
This document is not applicable to equipment:
– with samplers and concentrators such as sorbents or paper tape having an irreversible
indication;
– used for the measurement of gases and vapours related to the risk of explosion;
– used for the measurement of oxygen;
– used only in laboratories for analysis or measurement;
– used only for process measurement purposes;
– used in the domestic environment;
– used in environmental air pollution monitoring;
– used for open-path (line of sight) area gas measurement;
– used for ventilation control in car parks or tunnels.

---------------------- Page: 11 ----------------------
oSIST prEN IEC 62990-1:2022
– 8 – IEC 62990-1:2019 © IEC 2019
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal)
IEC 60079-0, Explosive atmospheres – Part 0: Equipment – General requirements
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 61000-4-29, Electromagnetic compatibility (EMC) – Part 4-29: Testing and measurement
techniques – Voltage dips, short interruptions and voltage variations on d.c. input power port
immunity tests
IEC 61000-6-3, Electromagnetic compatibility (EMC) – Part 6-3: Generic standards –
Emission standard for residential, commercial and light-industrial environments
IEC 61000-6-4, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards –
Emission standard for industrial environments
IEC 61326-1, Electrical equipment for measurement, control and laboratory use – EMC
requirements – Part 1: General requirements
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
gas properties
3.1.1
ambient air
normal atmosphere surrounding the equipment
3.1.2
clean air
air that is free of gases or vapours which the sensor is sensitive to or which influence the
performance of the sensor
3.1.3
occupational exposure limit value
OELV
limit of the time-weighted average of the concentration of a chemical agent in the air within
the breathing zone of a worker in relation to a specified reference period
Note 1 to entry: The term “limit value” is often used as a synonym for “occupational exposure limit value”, but the
term “occupational exposure limit value” is preferred because there is more than one limit value (e.g., biological
limit value and occupational exposure limit value).

---------------------- Page: 12 ----------------------
oSIST prEN IEC 62990-1:2022
IEC 62990-1:2019 © IEC 2019 – 9 –
Note 2 to entry: Occupational exposure limit values (OELVs) are often set for reference periods of 8 h, but can
also be set for shorter periods or concentration excursions.
[SOURCE: ISO 18158:2016, 2.1.5.4, modified (Note 2 to entry is shortened)]
3.1.4
reference value
value used as the basis to specify requirements such as measuring
range, resolution and alarm set point
Note 1 to entry: The term reference value is used in this document because for most toxic gases and vapours the
occupational exposure limit values have not been harmonized at the International level.
3.1.5
poisons
substances that lead to temporary or permanent change of
performance, particularly loss of sensitivity of the sensing element
3.1.6
toxic gas
gas or vapour that can be harmful to human health and/or the performance of persons due to
its physical or physico-chemical properties
Note 1 to entry: For the purpose of this document, the term “toxic gas” includes “toxic vapours”.
3.1.7
volume fraction
quotient of the volume of a specified component and the sum of the volumes of all
components of a gas mixture before mixing, all volumes referring to the pressure and the
temperature of the gas mixture
Note 1 to entry: The volume fraction and volume concentration take the same value if, at the same state
conditions, the sum of the component volumes before mixing and the volume of the mixture are equal. However,
because the mixing of two or more gases at the same state conditions is usually accompanied by a slight
contraction or, less frequently, a slight expansion,
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.