Abstract

On-site paging systems and relevant measuring methods ranging from LF up to and including UHF

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Documents

Standardization document

SIST ETS 300 224 E1:2003

English language (65 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 224 E1:2003 is the Slovenian standard from SIST that corresponds to ETS 300 224 Edition 1 from ETSI. It specifies minimum technical and functional characteristics, together with test methods, for on-site paging systems and their transmitters and receivers. The document is used by manufacturers, accredited test laboratories, and system buyers who need to check radio and loop paging equipment from LF up to UHF.

What does SIST ETS 300 224 E1:2003 specify?

SIST ETS 300 224 E1:2003 specifies the wireless part of on-site paging service equipment and the methods used to measure its performance. It covers fixed base station transmitters and receivers, pocket units, and inductive loop systems, with attention to type testing and presentation for test.

The scope is limited to radio and loop communications for a privately owned and operated paging system in a restricted site. It does not extend to radiation below 25 MHz except for loop equipment output, and additional standards may be needed when equipment interfaces with the Public Switched Telephone Network (PSTN).

The document is organized into 11 clauses and 6 annexes.

AnnexWhat it covers
Annex ARadiated measurements, test sites, antennas, and anechoic chamber guidance
Annex BInformative description of on-site paging, typical users, and spectrum efficiency
Annex CNormative support for pocket equipment
Annex DNormative specification of the power measuring receiver
Annex ENormative spurious radiation limits for loop systems
Annex FInformative bibliography

What are the key requirements of SIST ETS 300 224 E1:2003?

SIST ETS 300 224 E1:2003 focuses on how equipment is prepared for type testing, how measurements are made, and which transmitter, receiver, and loop-system characteristics are checked. In practice, this means the standard tells a test laboratory what to measure, under what conditions, and with what setup, so results are comparable across labs.

Equipment presentation and general rules

Clause 5 requires each submitted unit to meet the standard on all operating frequencies intended for use. For equipment with variable output power, measurements start at the highest setting and are repeated at the lowest setting for key transmitter tests. If the unit operates intermittently, the declared transmit time and duty cycle must be respected during testing.

Clause 5 also sets practical rules for test samples. Equipment must be marked with the manufacturer identity and type designation, controls that could increase interference should not be easy for the user to adjust, and any automatic transmitter shut-off or receiver mute/squelch or battery-saving function is made inoperative during the tests. This matters because the lab needs to see the underlying RF performance, not a protected or altered operating mode.

Test conditions and test setup

Clauses 6 and 7 define normal and extreme test conditions, power sources, and ambient temperatures. Transmitter tests use a 50 ohm non-reactive, non-radiating artificial load, and equipment with an integral antenna may need a test fixture that couples the antenna to a 50 ohm RF terminal. That allows conducted measurements where a normal connector is not available.

For radiated measurements, the test site must be an open-air arrangement, with Annex A giving guidance on outdoor and indoor sites, including anechoic chambers. Receiver input signals must be applied through a network that presents 50 ohm impedance. This keeps the measurement conditions controlled and repeatable.

Transmitter requirements

Clause 8 covers the core transmitter checks: frequency error, carrier power, adjacent channel power, frequency deviation, spurious radiations, and transient behaviour. These checks show whether the transmitter stays on frequency, stays within its intended channel, and avoids unwanted emissions when it keys on and off. For intermittent systems, the declared transmit limits apply, and the report must note the maximum transmit time.

Clause 8 also uses declared test paths for frequency error and extreme-condition testing. For variable-power units, the important transmitter measurements are repeated at lower power too. In practice, buyers and integrators use this part to confirm that the transmitter behaves properly across the full operating range, not only at one preferred setting.

Receiver requirements

Clause 9 separates pocket paging receivers from base station receivers. Pocket receivers are checked for spurious radiations, while base station receivers are evaluated for measured sensitivity, co-channel rejection, adjacent channel selectivity, spurious response immunity, intermodulation immunity, blocking or desensitisation, and spurious radiations for both analogue speech and messages.

These receiver tests matter because on-site paging often operates in busy radio environments. The standard checks whether a receiver can still respond to the wanted call while ignoring nearby or unwanted signals, and whether it can support both speech and message services where those functions are implemented.

Inductive loop systems

Clause 10 adds requirements for inductive loop paging systems, which use VLF and LF frequencies to transfer information to pocket receivers. It defines additional terms, covers single-carrier and multi-carrier loop equipment, and sets transmitter and receiver requirements for carrier power, operating frequency range, frequency error, modulation bandwidth, and spurious radiations.

Clause 10 is especially important because loop systems have their own emission limits, including different limits below 25 MHz and above 25 MHz. Annex E gives the graphical representation of those limits. In practice, this clause is the part to use when the paging system is based on building loops rather than conventional radio antennas.

Measurement uncertainty

Clause 11 ties the test results to measurement uncertainty values from ETR 028. The standard requires the uncertainty to be stated in the test report and kept within the figures referenced there. That is important for type testing because a result is only meaningful when the laboratory can show the uncertainty behind it.

What terms does SIST ETS 300 224 E1:2003 define?

  • Pocket unit: Pocket-size equipment carried by a person or held in the hand, with an integral antenna.
  • Preamble facility: A signal used to wake up and prepare battery-saving receivers for incoming calls.
  • Talk-back facility: A mode that lets a pocket unit send speech messages back to the base stations after a selective call.
  • Call acknowledgement facility: A short return signal from the pocket unit to confirm reception of a call.
  • Public Switched Telephone Network (PSTN): The public telephone network that may need separate interface requirements when equipment connects to it.
  • Signal + Noise And Distortion / (Noise + Distortion) ratio (SINAD): A receiver performance ratio used in sensitivity and blocking measurements.
  • Voltage Standing Wave Ratio (VSWR): A measure used here for matching and artificial-load performance during transmitter tests.

Who uses SIST ETS 300 224 E1:2003?

Manufacturers use SIST ETS 300 224 E1:2003 when designing and submitting on-site paging transmitters, receivers, pocket units, and loop equipment for type testing. Accredited test laboratories use it to plan measurements, choose test sites, and report results in a consistent way.

System integrators and engineering teams use it when combining paging with PBX, intercom, security, or nurse-call systems, because the standard describes the paging side of the installation. Buyers and quality managers in hospitals, industry, public administration, and hotel or department-store environments use it to understand what kind of paging equipment and testing approach the standard covers.

What changed in SIST ETS 300 224 E1:2003 from the previous edition?

SIST ETS 300 224 E1:2003 corresponds to ETS 300 224 Edition 1. The history notes that the original first edition was issued in May 1994, and that the document was converted to PDF in March 1996.

Which standards are used with SIST ETS 300 224 E1:2003?

ETR 027, Radio Equipment and Systems (RES); Methods of measurement for mobile radio equipment, supports the radiated measurement sites and arrangements used in Annex A.

ETR 028, Radio Equipment and Systems (RES); Uncertainties in the measurement of mobile radio equipment characteristics, provides the uncertainty figures used in Clause 11 and in test reporting.

The foreword says the ETS is based mainly on CEPT Recommendation T/R 20-05 and ESPA publication 4.2.6, with ESPA publication 4.2.6.a for loop systems. Annex F lists those publications in the bibliography.

What does the SIST ETS 300 224 E1:2003 document contain?

The document contains clause-by-clause test methods for transmitter and receiver performance, plus setup rules for type testing. It includes measurement procedures for frequency error, carrier power, adjacent channel power, frequency deviation, spurious radiations, transient behaviour, sensitivity, rejection, selectivity, immunity, and blocking.

It also contains supporting material that test labs use directly: radiated test-site guidance in Annex A, pocket-equipment support in Annex C, and the power measuring receiver specification in Annex D. Annex E presents loop-system spurious radiation limits graphically, while Annex B explains the on-site paging service and its typical users.

Buy Documents

Standardization document

SIST ETS 300 224 E1:2003

English language (65 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 224 E1:2003 is a standardization document published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio Equipment and Systems (RES); On-site paging service; Technical and functional characteristics for on-site paging systems, including test methods". This standard covers: On-site paging systems and relevant measuring methods ranging from LF up to and including UHF

On-site paging systems and relevant measuring methods ranging from LF up to and including UHF

SIST ETS 300 224 E1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.070.20 - Paging systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 224 E1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Definitions and abbreviations
  • 3.1 Definitions
  • 3.2 Abbreviations
  • 4 Functional characteristics
  • 4.1 On-site paging system description
  • 4.2 On-site paging system basic services
  • 4.3 Description of additional functional characteristics
  • 5 General
  • 5.1 Presentation of radio paging equipment for testing purposes
  • 5.2 Mechanical and electrical design
  • 5.3 Marking (Equipment Identification)
  • 5.4 Controls
  • 5.5 Transmitter shut-off facility
  • 5.6 Receiver mute or squelch circuit
  • 5.7 Declarations by the manufacturer
  • 5.8 Auxiliary test equipment
  • 5.9 Categories of emission
  • 5.10 Interpretation of the measurement results
  • 6 Test conditions, power sources and ambient temperatures
  • 6.1 Normal and extreme test conditions
  • 6.2 Normal operational test conditions
  • 6.3 Extreme test conditions
  • 7 Electrical test conditions
  • 7.1 Normal test signals and test modulation
  • 7.2 Artificial load
  • 7.3 Test fixture for transmitters with an integral antenna
  • 7.4 Test site and general arrangements for the measurement of radiated fields
  • 7.5 Arrangements for test signals applied to the receiver input
  • 8 Transmitter requirements
  • 8.1 Frequency error
  • 8.2 Carrier power
  • 8.3 Adjacent channel power
  • 8.4 Frequency deviation
  • 8.5 Spurious radiations
  • 8.6 Transmitter transient behaviour
  • 9 Receiver requirements
  • 9.1 Pocket paging receivers
  • 9.2 Base station receivers
  • 10 Inductive loop systems
  • 10.1 Additional definitions for inductive systems
  • 10.2 General
  • 10.3 Loop transmitter requirements
  • 10.4 Receiver requirements
  • 11 Measurement uncertainty
  • 11.1 Absolute measurement uncertainties: maximum values
  • Annex A (normative): Radiated measurements
  • 1. Equipment under test
  • 2. Test antenna
  • 3. High pass filter (may not be necessary)
  • 4. Spectrum analyzer or measuring receiver
  • 30 AAAAAAAAAAAAAAAAAAA
  • Annex B (informative): Detailed on-site description
  • Annex C (normative): Support for pocket equipment
  • Annex D (normative): Specification of power measuring receiver
  • Annex E (normative): Spurious radiation limits for loop systems
  • Annex F (informative): Bibliography

1 Scope

This ETS specifies the minimum performance characteristic and the related methods of measurement for on-site paging transmitters and receivers. Although this ETS covers the general operational aspects of onsite paging systems, it is restricted to the wireless (radio and loop) communications of the service. It is assumed that the radio type of system will operate in the frequency range of 25 MHz to 470 MHz, and loop systems below 150 kHz.

This ETS does not cover radiation below 25 MHz, except for the output of loop equipment. Additional standards or specifications may be required for equipment intended to interface to the Public Switched Telephone Network (PSTN).

This ETS may be used by accredited test laboratories for type testing of the equipment. This ETS also contains instructions for the presentation of equipment for type testing purposes. The types of equipment covered by this ETS are as follows:

  • base station transmitters (radio and loop), with or without an external 50 W antenna connector;
  • base station receivers, with a permanent 50 W connector;
  • pocket unit (receiver, transceiver or transmitter), with or without an external 50 W antenna connector.

Annex A: provides information concerning test sites and general arrangements for measurements involving the use of radiated fields.

Annex B: provides information concerning the on-site paging service. Annex C: provides normative information concerning measuring support for pocket equipment. Annex D: contains normative specifications for adjacent channel power measuring receiver. Annex E: is a graphic representation of the normative subclause 10.4.1.3 referring to the limits for spurious radiations of loop receivers.

Annex F: contains a list of informative references.

2 Normative references

This ETS incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.

[1] ETR 027: "Radio Equipment and Systems (RES); Methods of measurement for mobile radio equipment".

[2] ETR 028: "Radio Equipment and Systems (RES); Uncertainties in the measurement of mobile radio equipment characteristics".

SIST ETS 300 224 E1:2003 Page 12 ETS 300 224: May 1994

3 Definitions and abbreviations

3.1 Definitions

For the purpose of this ETS, the following definitions apply:

Constant envelope modulation: either phase or frequency modulation with or without pre-emphasis. Integral antenna: an antenna designed as an indispensable part of the equipment, with or without the use of an antenna connector.

Coded messages: the transmission of messages to a paging receiver via coded signals. Base station transmitter: transmitter intended for use in a fixed location. Base station receiver: receiver intended for use in a fixed location. Pocket unit: pocket size equipment fitted with an integral antenna carried on a person or held in the hand. Preamble facility: a signal, needed in a system in which a battery saving system is used, in order to activate and prepare receivers for the calls to come.

Category AR1: see subclause 5.1.3.

Category AR2: see subclause 5.1.3.

3.2 Abbreviations

For the purpose of this ETS, the following abbreviations apply:

dBm DeciBels relative to 1 mW emf electro-motive force LF The frequency range 30 kHz to 300 kHz (Low Frequency) PBX Private Branch Exchange PSTN Public Switched Telephone Network RF Radio Frequency rms root-mean-squared Rx Receiver SINAD (Signal + Noise And Distortion) / (Noise + Distortion) ratio Tx Transmitter VLF The frequency range 3 kHz to 30 kHz (Very Low Frequency) VSWR Voltage Standing Wave Ratio

4 Functional characteristics

4.1 On-site paging system description

An on-site paging system is a privately owned and operated, wireless communication system, used in a restricted and predefined area, with the primary function to alert and/or inform ambulant people. The air interface of the system, using a single radio channel, comprises at least one transmitter. The paging system may be extended with a return frequency. This return or talk-back frequency is mainly used for call acknowledgement but may also be used to supply some of the features of a mobile radio service or other two-way radio services, without the need to use a separate system. The radio part of an approved on-site paging system is made up exclusively from equipment that has been approved according to this ETS. Other equipment that may be connected to it shall fulfil the standards applicable to that equipment (if any).

SIST ETS 300 224 E1:2003 Page 13 ETS 300 224: May 1994 Annex B provides a more detailed description of the on-site paging system.

4.2 On-site paging system basic services

The main services that can be obtained through an on-site paging system are a function of the capabilities of the pocket units.

The simplest and most well known paging receiver is a selective call receiver with an alerting device. When paged, the pocket unit generates a certain alerting pattern and the user should take some pre-determined actions. The receiver may also receive a spoken message after the alert signal. When the receiver is equipped with a visual display, limited text messages can be presented to the user by additional transmission of data. If the receiver is equipped with a transmitter, the user can acknowledge a message and/or establish a speech connection.

System configurations include:

  • alert only;
  • alert + data one way;
  • alert + data two ways;
  • alert + voice one way;
  • alert + voice two ways;
  • alert + data + voice one way;
  • alert + data + voice two ways.

Different users have different communication requirements. Therefore, most paging systems allow any mixture of pocket units. The size of an on-site paging system, in number of pocket units, may vary from one to several thousand units.

4.3 Description of additional functional characteristics

Call acknowledgement facility: call acknowledgement is the feature enabling the transmission of a short signal from the pocket unit to the base station(s) to confirm the reception of a call. Dial-in facility: dial-in is the facility whereby a pocket transceiver forming part of a paging system is able to initiate a call to the base station(s).

Dial-out facility: dial-out is the facility allowing a pocket paging transceiver to initiate a call, via a base station, to another external on-site communication network, accessible from the paging system, e.g. a Private Branch Exchange (PBX).

Dial-through facility: dial-through is the facility allowing a pocket paging transceiver to initiate a call to another pocket unit belonging to the same paging system via the base station. Periodic calls facility: periodic calls are paging calls which are transmitted at regular intervals by the base station(s) e.g. "time of day" and "out of range".

Preamble facility: a preamble is a signal needed in a system in which a battery saving system is used in order to activate and prepare receivers for the calls to come.

SIST ETS 300 224 E1:2003 Page 14 ETS 300 224: May 1994 Speech facility: the speech facility is the mode of operation allowing the transmission of speech messages from the base stations to the paging receivers.

Talk-back facility: talk-back is the mode of operation enabling the transmission of speech messages from the pocket units to the base stations after the reception of a selective call from the base station. Talk-through facility: talk-through is the application in which a speech signal from a pocket transceiver is relayed by the base station(s) and transmitted to another pocket transceiver of the same system and site. In order to make maximum use of the allocated radio channels (1 outgoing and 1 return), and to give maximum flexibility to the user, the user may install and use any combination of the features of the system. In addition to normal paging calls this includes:

Call acknowledgement:

  • speech;
  • talk-back;
  • talk-through.

Dial-in:

  • dial-out;
  • dial-through;
  • the use of multi-transmitter systems (working on 1 frequency);
  • the use of diversity (multi-receiver) reception for the base station receiver system;
  • the transmission of periodic calls and preambles.

Where spectrum is available, there will be no restrictions on the use of these functions, nor will there be any time limitations. However, giving the fact that frequencies for on-site paging are never exclusive, an excessive use of the possible facilities will be no justification for further spectrum allocation for the same system and site.

Moreover, in order to cope with practical situations it is recommended that base transmitters with a maximum rated output power of more than 1 Watt (W) should be set to operate between 1 W and their rated maximum output power.

5 General

5.1 Presentation of radio paging equipment for testing purposes

Each equipment submitted for type testing shall fulfil the requirements of this ETS on all frequencies over which it is intended to operate.

To simplify and harmonise the type testing procedures between the different test laboratories, measurements shall be performed according to this ETS. The following subclauses are intended to give confidence that the requirements set out in this ETS have been met.

SIST ETS 300 224 E1:2003 Page 15 ETS 300 224: May 1994

5.1.1 Choice of model for type approval

The manufacturer shall provide one or more production models of equipment, as appropriate, for type testing. If type approval is given on the basis of tests on a preliminary model, the corresponding production models shall be identical in all respects with the preliminary model tested. In the case of equipment without an external antenna connector see subclause 5.1.7.

5.1.2 Definition of alignment range

The manufacturer shall, when submitting equipment for test, state the alignment range for the receiver or the transmitter. The alignment range is defined as the frequency range over which the receiver or the transmitter can be programmed and/or re-aligned to operate without any physical change of components other than programmable read only memories or crystals (for the receiver and the transmitter). For the purpose of all measurements the receiver and transmitter shall be considered separately.

5.1.3 Definition of the categories of the alignment range (AR1 and AR2)

Category AR1 corresponds to a limit of the alignment range of the receiver and transmitter which is less than, or equal to, 10 % of the highest frequency of the alignment range. Category AR2 corresponds to a limit of the alignment range of the receiver and transmitter which is greater than 10 % of the highest frequency of the alignment range.

5.1.4 Choice of frequencies

The frequencies for testing shall be chosen by the manufacturer in accordance with subclauses 5.1.5 and 5.1.6.

5.1.5 Testing of equipment of category AR1 Full tests shall be carried out on a channel within 100 kHz of the center frequency of the alignment range of one sample of the equipment.

5.1.6 Testing of equipment of category AR2 Full tests shall be carried out on three samples of the equipment, each sample aligned to a different channel.

The frequency of the channel of:

  • the first sample shall be within 100 kHz of the lowest frequency of the alignment range;
  • the second sample shall be within 100 kHz of the center frequency of the alignment range;
  • the third sample shall be within 100 kHz of the highest frequency of the alignment range.
5.1.7 Testing of equipment without an external 50 W antenna connector

To facilitate relative measurements, use can be made of a test fixture as described in subclause 7.3, or the equipment can be supplied with a permanent or temporary internal 50 W connector or a temporary external 50 W connector.

5.1.7.1 Equipment with a permanent internal 50 W RF connector

The way to access a permanent internal 50 W RF connector shall be stated by the manufacturer with the aid of a diagram. The fact that use has been made of a permanent internal 50 W Radio Frequency (RF) socket shall be recorded in the test report.

SIST ETS 300 224 E1:2003 Page 16 ETS 300 224: May 1994

5.1.7.2 Equipment with a temporary 50 W connector

The applicant shall submit two sets of equipment to the test laboratory, one fitted with a temporary 50 W RF connector with the antenna disconnected and the other with the antenna connected. Each equipment shall be used for the appropriate tests.

The way the temporary 50 W RF connector is implemented shall be stated by the manufacturer with the aid of a diagram. The fact that use has been made of the temporary 50 W RF connector to facilitate measurements shall be stated in the test report. The addition of a temporary 50 W RF connector shall not influence the performance of the equipment under test.

5.2 Mechanical and electrical design

Transmitters and receivers may be individual or combination units but shall operate with the correct power source. The equipment submitted shall be designed, constructed and manufactured in accordance with sound engineering practice, and with the aim of minimising harmful interference to other equipment and services.

5.3 Marking (Equipment Identification)

The equipment shall be marked in a visible place. This marking shall be legible and durable. The marking shall include as a minimum:

  • the name of the manufacturer or his trademark;
  • the type designation.

The type designation shall allow recognition of the multiple unit type of assembly.

5.4 Controls

Those controls, which if maladjusted might increase the interfering potentialities of the equipment, shall not be easily accessible to the user.

5.5 Transmitter shut-off facility

If the transmitter is fitted with an automatic shut-off facility, it should be made inoperative for the duration of the test.

5.6 Receiver mute or squelch circuit

If the receiver is equipped with a mute, squelch or battery-saving circuit, this circuit shall be made inoperative for the duration of the tests.

5.7 Declarations by the manufacturer

When submitting equipment for type testing, the manufacturer shall supply the necessary information according to the appropriate application form.

5.8 Auxiliary test equipment

All necessary test signal sources and setting up information shall accompany the equipment when it is submitted for type testing.

SIST ETS 300 224 E1:2003 Page 17 ETS 300 224: May 1994

5.9 Categories of emission

All types of constant envelope modulation by code and speech are permitted, which shall meet the limits of this ETS.

5.10 Interpretation of the measurement results

The interpretation of the results recorded in a test report for the measurements described in this ETS shall be as follows.

The measured value related to the corresponding limit shall be used to decide whether an equipment meets the requirements of the standard.

The measurement uncertainty value for the measurement of each parameter shall be included in the test report.

The recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures in the table of measurement uncertainty as published in ETR 028 [2].

6 Test conditions, power sources and ambient temperatures

6.1 Normal and extreme test conditions

Type tests shall be made under normal operational conditions, and where stated under extreme conditions. The test conditions and procedures shall be as specified in subclauses 6.2 and 6.3.

6.2 Normal operational test conditions

6.2.1 Normal temperature and humidity

The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:

  • temperature: +15 °C to +35 °C;
  • relative humidity: 20 % to 75 %.

When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report.

6.2.2 Normal test power source

a) Mains supply:

The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of type testing to this ETS, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.

The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz. b) Other power sources:

For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer and approved by the test authority. Such values shall be stated in the test report.

SIST ETS 300 224 E1:2003 Page 18 ETS 300 224: May 1994 NOTE: In pocket equipment with integral antenna, the battery cannot be replaced with an external power source when making radiating measurements, because this external power source could influence the test results.

6.3 Extreme test conditions

6.3.1 Procedure for tests at extreme temperatures

Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched to stand-by during the temperature stabilising period. In the case of equipment containing stabilisation circuits designed to operate continuously, the temperature stabilisation arrangements shall be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source to the rest of the equipment.

a) Procedure for equipment designed for continuous operation.

If the manufacturer states that the equipment is designed for continuous operation, the procedure shall be as follows:

- before tests at the upper temperature, the equipment shall be placed in the test chamber and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition for a period of half an hour, after which the equipment shall meet the specified requirements. For tests at the lower temperatures, the equipment shall be left in the test chamber until thermal balance is attained, after which the equipment shall meet the specified requirements. b) Procedure for equipment designed for intermittent operation. If the applicant states that the equipment is designed for intermittent operation, the test procedure shall be as follows:

  • before tests at the upper extreme temperature are made, the equipment shall be placed in the test chamber and left until thermal balance is attained in the test chamber. The equipment shall then either:
  • transmit "on" and "off", according to the duty cycle as declared by the applicant, for a period of 5 minutes; or
  • if the "on" period as declared by the applicant exceeds 1 minute, transmit in the "on" condition for a period not exceeding 1 minute, followed by a period in the "off" or "standby" mode for 4 minutes, after which the equipment shall meet the specified requirements. For tests at the lower extreme temperature the equipment shall be left in the test chamber until thermal balance is attained, then the equipment shall be switched to the "standby" or "receive" condition for 1 minute, after which the equipment shall meet the specified requirements.
6.3.2 Extreme temperature limits

For tests at extreme temperatures, measurements shall be made in accordance with procedures specified in subclause 6.3.1 over an ambient temperature range of:

...