Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW

This document specifies, for the purpose of type examination, the requirements and test methods for construction, safety, marking and rational use of energy of 2nd and 3rd family gas-fired domestic flueless space heating appliances having a nominal input not exceeding 6 kW (based on net calorific value).
It covers the following Type AAS fixed flueless heaters:
NOTE   These are type A appliances fitted with an atmosphere sensing device, with or without a fan.
a)   heaters with or without a catalytic converter;
b)   Category 1 appliances burning gases of the second family;
c)   Category 2 appliances burning gases of the second and third families.
It does not cover
i.   Mobile heaters.
ii.   Category 1 appliances burning gases of the third family.
iii.   Portable flueless heaters.
iv.   Diffusive catalytic combustion heaters.
There are no specific thermal efficiency requirements appropriate to these types of appliance as:
   All the heat produced by the combustion process is released into the space to be heated.
   The requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas.
This standard is only applicable to appliances which are to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.

Konvektions-Raumheizer ohne Abgasabführung für gasförmige Brennstoffe mit einer Nennwärmebelastung kleiner oder gleich 6 kW

Dieses Dokument legt Anforderungen und Prüfbestimmungen für Bau, Sicherheit, Kennzeichnung und
rationelle Energienutzung von Konvektions-Raumheizern ohne Abgasabführung für gasförmige Brennstoffe
mit einer Nennwärmebelastung kleiner oder gleich 6 kW (bezogen auf den unteren Heizwert) fest, die für
Gase der 2. und 3. Familie gebaut sind. Diese Norm gilt für Baumusterprüfungen.
Sie gilt für folgende fest eingebaute Heizer ohne Abgasführung vom Typ AAS:
ANMERKUNG Die Geräte vom Typ A, mit und ohne Gebläse, sind mit einem atmosphärischen Fühler ausgestattet.
a) Heizer mit oder ohne Katalysator;
b) Geräte der Kategorie 1, die Gase der 2. Familie verbrennen;
c) Geräte der Kategorie 2, die Gase der 2. und 3. Familie verbrennen.
Sie gilt nicht für
i) mobile Heizgeräte,
ii) Geräte der Kategorie 1, die Gase der 3. Familie verbrennen,
iii) tragbare Heizer ohne Abgasabführung,
iv) diffuse katalytische Verbrennungsheizgeräte.
Es gibt keine spezifischen Bestimmungen des thermischen Wirkungsgrades, die für diese Gerätetypen
geeignet sind wie:
EN 14829:2007 (D)
7
⎯ Die gesamte Hitze, die durch den Verbrennungsprozess entsteht, gelangt an die Stelle, die beheizt
werden soll.
⎯ Die Bestimmungen bezüglich der Verbrennungsleistung, die eine Sicherheitsangelegenheit darstellt,
stellen die wirkungsvolle Verbrennung der Abgase sicher.
Diese Norm ist lediglich anwendbar auf Geräte, die geprüft werden sollen. Angelegenheiten im Zusammenhang
mit Qualitätssicherungssystemen, laufenden Produktionskontrollen und Konformitätszertifizierungen von
Zusatzeinrichtungen sind nicht Gegenstand dieser Norm.

Appareils de chauffage domestiques non raccordés indépendants utilisant les combustibles gazeux pour un débit calorifique nominal inférieur ou égal a 6 kW

Le présent document spécifie, pour les besoins d'un examen de type, les exigences et les méthodes d'essai relatives à la construction, la sécurité, le marquage et l'utilisation rationnelle de l'énergie par les appareils de chauffage domestiques non raccordés utilisant les combustibles gazeux des deuxième et troisième familles, dont le débit nominal est inférieur ou égal à 6 kW (sur la base du pouvoir calorifique inférieur).
La présente norme couvre les appareils fixes non raccordés de type AAS suivants :
NOTE   Ce sont des appareils de type A équipés d’un dispositif de contrôle d’atmosphère, avec ou sans ventilateur.
a)   les appareils de chauffage avec ou sans convertisseur catalytique ;
b)   les appareils de catégorie 1 utilisant des gaz de la deuxième famille ;
c)   les appareils de catégorie 2 utilisant des gaz des deuxième et troisième familles.
La présente norme ne couvre pas :
i)   les appareils de chauffage mobiles ;
ii)   les appareils de catégorie 1 utilisant des gaz de la troisième famille ;
iii)   les appareils de chauffage non raccordés portatifs ;
iv)   Les appareils à combustion catalytique diffusive.
Il n'existe aucune exigence spécifique concernant le rendement thermique, appropriée à ces types d'appareils, dans la mesure où :
   Toute la chaleur produite par le processus de combustion se dégage dans l'espace à chauffer ;
                Les exigences concernant les performances de combustion, qui relèvent de la sécurité, assurent la combustion effective du combustible gazeux.
La présente norme s'applique uniquement aux appareils devant être soumis à un essai de type. Les aspects relatifs aux systèmes d’assurance qualité, aux essais pendant la production et aux certificats de conformités des équipements auxiliaires ne sont pas considérés dans cette norme.

Prostostoječi plinski grelniki za gretje prostorov brez priključka na dimnik z imensko močjo do vključno 6 kW

General Information

Status
Published
Publication Date
02-Dec-2007
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
25-Sep-2007
Due Date
30-Nov-2007
Completion Date
03-Dec-2007
Standard
SIST EN 14829:2008
English language
81 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kWAppareils de chauffage domestiques non raccordés indépendants utilisant les combustibles gazeux pour un débit calorifique nominal inférieur ou égal a 6 kWKonvektions-Raumheizer ohne Abgasabführung für gasförmige Brennstoffe mit einer Nennwärmebelastung kleiner oder gleich 6 kWTa slovenski standard je istoveten z:EN 14829:2007SIST EN 14829:2008en97.100.20Plinski grelnikiGas heatersICS:SLOVENSKI
STANDARDSIST EN 14829:200801-januar-2008

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14829August 2007ICS 97.100.20 English VersionIndependent gas-fired flueless space heaters for nominal heatinput not exceeding 6 kWAppareils de chauffage domestiques non raccordésindépendants utilisant les combustibles gazeux pour undébit calorifique nominal inférieur ou égal à 6 kWKonvektions-Raumheizer ohne Abgasabführung fürgasförmige Brennstoffe mit einer Nennwärmebelastungkleiner oder gleich 6 kWThis European Standard was approved by CEN on 24 June 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14829:2007: E

....................................................................................................................................29 6.8.2 Limit gas
............................................................................................................................................29 6.8.3 Appliances fitted with a fan to assist in the evacuation of the products of combustion..........................................................................................................................................29 6.8.4 Normal and abnormal voltage fluctuation .......................................................................................29 6.8.5 Measurement of nitrogen dioxide (NO2)...........................................................................................29 6.8.6 Values to be used in Annex G...........................................................................................................29 6.9 Sooting.................................................................................................................................................29 6.9.1 Cold condition.....................................................................................................................................29

National situations.55 A.1 General.55 A.2 Marketing in different countries of the categories listed in the text of the standard.55 A.3 Supply pressures for the appliances corresponding to the categories given in A.2.57 A.4 Special categories marketed nationally or locally.59 A.4.1 General.59 A.4.2 Definition of special categories.60 A.4.3 Gas rate adjusters, aeration adjusters and regulators.62 A.4.4 Conversion to different gases.62 A.5 Test gases corresponding to the special categories given in A.4.62 A.6 Gas connections in the various countries.65 Annex B (informative)
Gas valve arrangements for automatic controls for automatic control.66

Means of identification of the types of gas in use in the various countries.67 Annex D (normative)
Apparatus for the determination of the smoke number.68 D.1 Pump.68 D.2 Sampling tube.68 D.3 Filter paper.68 D.4 Grey scale.68 Annex E (normative)
Dress guards.70 E.1 Scope.70 E.2 Requirements.70 E.2.1 Access.70 E.2.2 Strength.70 E.3 Tests.70 E.3.1 Access.70 E.3.2 Strength.71 Annex F (normative)
Vitiation room.73 F.1 Dimensions.73 F.2 Sealing requirement.73 F.3 Construction.73 Annex G (normative)
Room size and ventilation.75 G.1 General.75 G.2 Room size.75 G.2.1 General.75 G.2.2 Maximum allowable gas input with regard to CO emissions.76 G.2.3 Maximum allowable gas input with regard to NO2 emissions.76 G.2.4 Calculation of minimum room size.77 G.2.5 Ventilation.77 Annex H (informative) A-deviation.78 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 90/396/EEC.79 Bibliography.81

c) Category 2 appliances burning gases of the second and third families. It does not cover
i. Mobile heaters. ii. Category 1 appliances burning gases of the third family. iii. Portable flueless heaters. iv. Diffusive catalytic combustion heaters. There are no specific thermal efficiency requirements appropriate to these types of appliance as:  All the heat produced by the combustion process is released into the space to be heated.  The requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas. This standard is only applicable to appliances which are to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 88-1, Pressure regulators and associated safety devices for gas appliances – Part 1: Pressure regulators for inlet pressures up to and including 500 mbar EN 125, Flame supervision devices for gas burning appliances — Thermoelectric flame supervision devices EN 126, Multifunctional controls for gas burning appliances EN 161, Automatic shut-off valves for gas burners and gas appliances EN 257, Mechanical thermostats for gas-burning appliances

Symbol Hs  the net calorific value in which the water produced by combustion is assumed to be in the vapour state.
Symbol Hi
Units: either:  megajoules per cubic metre (MJ/m3) of dry gas at the reference conditions; or  megajoules per kilogram (MJ/kg) of dry gas. 3.18 reference conditions  for calorific values, temperature: 15 °C;  for gas and air volumes dry, brought to 15 °C and an absolute pressure of 1 013,25 mbar.
3.19 Gas supply pressure 3.19.1 test pressure gas pressure used to verify the operational characteristics of appliances using combustible gases, consisting of normal and limit pressures They are expressed in millibar (mbar). NOTE 1 mbar = 100 Pa. 3.19.2 normal pressure pressure under which appliances operate in nominal conditions, when supplied with the corresponding reference gas Symbol: pn
3.19.3 limit pressures pressures representative of the extreme variations in appliance supply condition

3.19.4 pressure couple combination of two distinct gas distribution pressures applied by reason of the significant difference existing between the Wobbe indices within a single family or group in which:  the higher pressure corresponds only to gases of low Wobbe index; and  the lower pressure corresponds to gases of high Wobbe index. 3.20 light back phenomenon characterized by the return of the flame inside the body of the burner 3.21 tap device to adjust the heat input during use and/or isolate the gas supply to the various burners 3.22 sealing of an adjuster action whereby the locking of an adjuster is achieved by a means such that any attempt to change the adjustment makes the interference with the adjuster apparent (e.g. breaking of a sealing material) 3.23 soft solder solder for which the lowest temperature of the melting range, after application, is less than 450 °C 3.24 stability of flames condition of the flames at the burner ports or the flame contact area provided by the design when the phenomena of flame lift or light back do not occur 3.25 thermostat device to maintain automatically a selected constant temperature, it may include a graduated scale for the selection of the temperature 3.26 close-fronted appliance appliance which has no exposed flames or exposed incandescent areas 3.27 open-fronted appliance appliance which has exposed flames or exposed incandescent areas 3.28 cold condition condition of the appliance required for some tests and obtained by allowing the unit appliance to attain equilibrium at room temperature 3.29 hot condition condition of the appliance required for some tests and obtained by heating for one hour at the normal test pressure

non-volatile lock-out safety shut-down condition of the system, such that a restart can only be accomplished by a manual reset of the system and by no other means 3.38 safety time interval between the ignition burner gas valve, the start gas valve or main gas valve, as applicable, being energised and the ignition gas valve, start gas valve or main gas valve, as applicable, being de-energised if the flame detector signals the absence of a flame 3.39
spark restoration process by which, after disappearance of the flame signal in the running condition, the ignition device is energised again without the gas supply having been totally interrupted.
This process ends with the restoration of the running condition or, if there is no flame signal at the end of the safety time, with non-volatile lock-out 3.40
automatic recycling process by which, following loss of flame signal during the running condition or accidental interruption of the operation of the appliance, the gas supply is inte
...