SIST EN 13757-4:2019
(Main)Communication systems for meters - Part 4: Wireless M-Bus communication
Communication systems for meters - Part 4: Wireless M-Bus communication
This European Standard specifies the requirements of parameters for the physical and the link layer for systems using radio to read remote meters. The primary focus is to use the Short Range Device (SRD) unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed installations. As a broad definition, this European Standard can be applied to various application layers.
Kommunikationssysteme für Zähler und deren Fernablesung - Teil 4: Zählerauslesung über Funk (Fernablesung von Zählern im SRD-Band)
Systèmes de communication pour compteurs - Partie 4 : Communication sans fil M-Bus
La présente Norme européenne spécifie les exigences applicables aux paramètres de la couche physique et de la couche liaison associées aux systèmes de télérelevé de compteurs par radio. Elle est centrée essentiellement sur l’utilisation des bandes de télémesure libres pour dispositifs à courte portée (SRD). Elle traite à la fois des systèmes de relevé mobile à pied ou par véhicule et des installations fixes. La présente Norme européenne peut s’appliquer, par extension, à diverses couches application.
Komunikacijski sistemi za števce - 4. del: Brezžično komuniciranje po M-vodilu
Ta evropski standard določa zahteve parametrov za fizično plast in plast podatkovne povezave za sisteme, ki za daljinsko odbiranje števcev uporabljajo radijske valove. Osnovni cilj je uporaba nelicenciranih telemetričnih pasov za naprave kratkega dosega (SRD). Standard zajema sisteme za prehodne, prevozne in stacionarne naprave. Ta evropski standard se lahko kot široka definicija uporablja za različne aplikacijske nivoje.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 13757-4:2019
01-julij-2019
Nadomešča:
SIST EN 13757-4:2013
Komunikacijski sistemi za števce - 4. del: Brezžično komuniciranje po M-vodilu
Communication systems for meters - Part 4: Wireless M-Bus communication
Kommunikationssysteme für Zähler und deren Fernablesung - Teil 4: Zählerauslesung
über Funk (Fernablesung von Zählern im SRD-Band)
Systèmes de communication pour compteurs - Partie 4 : Communication sans fil M-Bus
Ta slovenski standard je istoveten z: EN 13757-4:2019
ICS:
33.200 Daljinsko krmiljenje, daljinske Telecontrol. Telemetering
meritve (telemetrija)
35.100.10 Fizični sloj Physical layer
35.100.20 Podatkovni povezovalni sloj Data link layer
SIST EN 13757-4:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 13757-4:2019
---------------------- Page: 2 ----------------------
SIST EN 13757-4:2019
EN 13757-4
EUROPEAN STANDARD
NORME EUROPÉENNE
May 2019
EUROPÄISCHE NORM
ICS 33.200; 35.100.10; 35.100.20 Supersedes EN 13757-4:2013
English Version
Communication systems for meters - Part 4: Wireless M-
Bus communication
Systèmes de communication pour compteurs - Partie 4 Kommunikationssysteme für Zähler - Teil 4: Drahtlose
: Communication sans fil M-Bus M-Bus-Kommunikation
This European Standard was approved by CEN on 25 February 2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13757-4:2019 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
Contents Page
European foreword . 6
Introduction . 7
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Abbreviations and symbols . 11
4.1 Abbreviation . 11
4.2 Symbols . 12
5 General . 12
5.1 Modes of operation . 12
5.2 Meter communications types. 13
5.3 Performance Classes . 15
6 Mode S . 16
6.1 Channel properties . 16
6.2 Transmitter . 17
6.3 Receiver . 18
6.4 Data encoding and preamble . 19
6.4.1 Data encoding . 19
6.4.2 Order of transmission of the encoded data . 19
6.4.3 Preamble and synchronization pattern . 19
7 Mode T . 19
7.1 Channel properties . 19
7.2 Transmitter . 19
7.3 Receiver (T2 only) . 22
7.4 Data encoding and preamble . 22
7.4.1 General . 22
7.4.2 Meter transmit, “3 out of 6” data encoding . 22
7.4.3 Other Device transmit, Manchester encoding . 24
8 Mode R2 . 24
8.1 Channel properties . 24
8.2 Transmitter . 24
8.3 Receiver . 26
8.4 Data encoding and preamble . 26
8.4.1 Data encoding . 26
8.4.2 Order of transmission of the encoded data . 26
8.4.3 Preamble and synchronization pattern . 26
9 Mode C . 27
9.1 Channel properties . 27
9.2 Transmitter . 27
9.3 Receiver . 29
9.4 Data encoding and preamble . 29
2
---------------------- Page: 4 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
9.4.1 Encoding . 29
9.4.2 Preamble and synchronization pattern . 29
10 Mode N . 30
10.1 Channel properties . 30
10.2 Physical link parameters . 31
10.3 Receiver sensitivity . 34
10.4 Data encoding and preamble . 34
10.4.1 Encoding . 34
10.4.2 Preamble and synchronization pattern . 34
11 Mode F . 35
11.1 Channel properties . 35
11.2 Physical link parameters . 35
11.3 Receiver sensitivity . 37
11.4 Data encoding and preamble . 37
11.4.1 Data Encoding . 37
11.4.2 Preamble and synchronization pattern . 37
12 Data Link Layer . 37
12.1 General . 37
12.2 Order of multi byte fields . 38
12.3 Frame format A . 38
12.4 Frame format B . 38
12.5 Field definitions . 39
12.5.1 General . 39
12.5.2 Multi byte fields . 39
12.5.3 Length field (L-Field) . 39
12.5.4 Control field (C-Field). 39
12.5.5 Manufacturer ID (M-field) . 41
12.5.6 Address (A-field) . 42
12.5.7 Cyclic redundancy check (CRC-field) . 42
12.5.8 Control information field (CI-field) . 42
12.6 Timing . 42
12.6.1 Timing for installation messages . 42
12.6.2 Synchronous transmissions of meter messages . 43
12.6.3 Access timing . 45
12.7 Repeated or duplicate messages . 46
12.8 Forward Error Correction (FEC) . 46
12.8.1 Overview . 46
12.8.2 Datagram structure. 46
12.8.3 FEC Algorithm . 47
13 Connection to higher protocol layers . 48
13.1 The Control Information Field (CI-field) . 48
13.2 CI-fields for the Extended Link Layer . 49
13.2.1 General . 49
13.2.2 CI-field = 8C . 50
h
13.2.3 CI-field = 8D . 50
h
13.2.4 CI-field = 8E . 50
h
13.2.5 CI-field = 8F . 51
h
13.2.6 CI-field = 86 . 51
h
13.2.7 Communication Control Field (CC-field) . 52
13.2.8 Access Number Field (ACC-field) . 54
3
---------------------- Page: 5 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
13.2.9 Manufacturer ID 2 (M2-field). 54
13.2.10 Address 2 (A2-field) . 54
13.2.11 Session Number Field (SN-field) . 54
13.2.12 AES-128 Counter Mode Encryption . 55
13.2.13 Run Time Delay field (RTD-field) . 56
13.2.14 Reception Level field (RXL-field) . 56
13.2.15 Payload Checksum Field (PayloadCRC-field) . 58
13.3 CI-fields for the Transport Layer . 58
13.3.1 General . 58
13.3.2 Short Transport Layer . 59
13.3.3 Long Transport Layer . 59
14 Management functions for link control . 59
14.1 General . 59
14.2 Set Radio Parameters . 63
14.2.1 General . 63
14.2.2 Command . 63
14.2.3 Response . 67
14.3 Get Radio Parameters . 69
14.3.1 General . 69
14.3.2 Command . 69
14.3.3 Response . 69
14.4 Set limited radio parameters . 71
14.4.1 General . 71
14.4.2 Command . 71
14.4.3 Response . 72
14.5 Confirm Radio Parameters . 73
14.5.1 General . 73
14.5.2 Command . 73
14.5.3 Response: . 73
14.6 Set manufacturer specific parameters . 74
14.6.1 General . 74
14.6.2 Command . 74
14.6.3 Response . 75
Annex A (informative) Frequency allocation and band usage for the 868 MHz band . 76
Annex B (informative) Frequency allocation for the 169 MHz band . 77
B.1 Frequencies and allowed power levels . 77
B.2 Frequencies and allowed duty cycles . 77
Annex C (informative) Frame examples . 78
C.1 Example of a frame from a meter in mode S . 78
C.1.1 Conditions . 78
C.1.2 Block content . 78
C.1.3 Bit string . 79
C.2 Example of a frame from a meter in mode T1 . 80
C.2.1 Condition . 80
C.2.2 Block Content . 80
C.2.3 Bit string . 81
4
---------------------- Page: 6 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
C.3 Example of a frame from a meter in mode C1 . 81
C.3.1 Conditions . 81
C.3.2 Block content . 82
C.3.3 Bit string . 82
Annex D (informative) Example of predictive reception of synchronous messages . 83
Annex E (informative) Timing diagrams . 84
Annex F (informative) Counter Mode Flow . 99
Bibliography . 100
5
---------------------- Page: 7 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
European foreword
This document (EN 13757-4:2019) has been prepared by Technical Committee CEN/TC 294
“Communication systems for meters”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2019, and conflicting national standards
shall be withdrawn at the latest by November 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 13757-4:2013.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
The main changes since EN 13757-4:2013 are as follows:
— Referenced standards have been updated to the most recent versions;
— Mode N, in the 169 MHz band has been extended to cover more frequencies see Clause 10;
— New C-field function code (Send User Data – No reply) added see 12.5.4;
— Extended timing tolerances for synchronous transmission see 12.6.2;
— Optional Forward Error Correction in the Link Layer added see 12.8;
— CI field for selectable Extended Link Layer added see 13.2;
— Management functions for link control added see Clause 14.
The standard is not affected by any of the requirements in Directive 2004/22/EC as it only covers the
basic transmission of information from the meter to an external entity. The standard ensures that data
transmitted cannot be modified without it being detected. Confidentiality, integrity and authenticity are
provided by the capabilities specified in other parts of the EN 13757 series of standards. The standard
does not specify any of the metering capabilities of the meter nor the metrological capabilities of the
meter.
The standard enables encrypted transfer data either directly or as specified in other parts of the
EN 13757 series of standards. The encryption ensures the confidentiality of any personal data.
The standard provides capabilities of interoperability of meters as requested in M/441 which can be
used to improve the customer awareness of actual consumption.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
6
---------------------- Page: 8 ----------------------
SIST EN 13757-4:2019
EN 13757-4:2019 (E)
Introduction
This European Standard belongs to the EN 13757 series, which covers communication systems for
meters.
EN 13757-1 contains generic descriptions and a communication protocol.
EN 13757-2 contains a physical and a link layer for twisted pair based Meter-Bus (M-Bus).
EN 13757-3 describes the application layer protocol
...
SLOVENSKI STANDARD
oSIST prEN 13757-4:2018
01-januar-2018
.RPXQLNDFLMVNLVLVWHPL]DãWHYFHGHO%UH]åLþQRNRPXQLFLUDQMHSR0YRGLOX
Communication systems for meters - Part 4: Wireless M-Bus communication
Kommunikationssysteme für Zähler und deren Fernablesung - Teil 4: Zählerauslesung
über Funk (Fernablesung von Zählern im SRD-Band)
Systèmes de communication pour compteurs - Partie 4 : Communication sans fil M-Bus
Ta slovenski standard je istoveten z: prEN 13757-4
ICS:
33.200 Daljinsko krmiljenje, daljinske Telecontrol. Telemetering
meritve (telemetrija)
35.100.10 )L]LþQLVORM Physical layer
35.100.20 Podatkovni povezovalni sloj Data link layer
oSIST prEN 13757-4:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 13757-4:2018
---------------------- Page: 2 ----------------------
oSIST prEN 13757-4:2018
DRAFT
EUROPEAN STANDARD
prEN 13757-4
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2017
ICS 33.200; 35.100.10; 35.100.20 Will supersede EN 13757-4:2013
English Version
Communication systems for meters - Part 4: Wireless M-
Bus communication
Systèmes de communication des compteurs - Partie 4: Kommunikationssysteme für Zähler und deren
Communication par radio, protocole M-bus Fernablesung - Teil 4: Zählerauslesung über Funk
(Fernablesung von Zählern im SRD-Band)
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 294.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13757-4:2017 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
Contents Page
European foreword . 6
Introduction . 7
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Symbols and abbreviations . 11
5 General . 12
5.1 Modes of operation . 12
5.2 Meter communications types. 13
5.3 Performance Classes . 15
6 Mode S . 16
6.1 Channel properties . 16
6.2 Transmitter . 17
6.3 Receiver . 18
6.4 Data encoding and preamble . 19
6.4.1 Data encoding . 19
6.4.2 Order of transmission of the encoded data . 19
6.4.3 Preamble and synchronization pattern . 19
7 Mode T . 19
7.1 Channel properties . 19
7.2 Transmitter . 19
7.3 Receiver (T2 only) . 21
7.4 Data encoding and preamble . 22
7.4.1 General . 22
7.4.2 Meter transmit, “3 out of 6” data encoding . 22
7.4.3 Other Device transmit, Manchester encoding . 24
8 Mode R2 . 24
8.1 Channel properties . 24
8.2 Transmitter . 24
8.3 Receiver . 25
8.4 Data encoding and preamble . 26
8.4.1 Data encoding . 26
8.4.2 Order of transmission of the encoded data . 26
8.4.3 Preamble and synchronization pattern . 26
9 Mode C . 27
9.1 Channel properties . 27
9.2 Transmitter . 27
9.3 Receiver . 28
9.4 Data encoding and preamble . 29
9.4.1 Encoding . 29
9.4.2 Preamble and synchronization pattern . 29
2
---------------------- Page: 4 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
10 Mode N . 30
10.1 Channel properties . 30
10.2 Physical link parameters . 31
10.3 Receiver sensitivity . 34
10.4 Data encoding and preamble . 35
10.4.1 Encoding . 35
10.4.2 Preamble and synchronization pattern . 35
11 Mode F . 36
11.1 Channel properties . 36
11.2 Physical link parameters . 36
11.3 Receiver sensitivity . 38
11.4 Data encoding and preamble . 38
11.4.1 Data Encoding . 38
11.4.2 Preamble and synchronization pattern . 38
12 Data Link Layer . 38
12.1 General . 38
12.2 Order of multi byte fields . 39
12.3 Frame format A . 39
12.4 Frame format B . 39
12.5 Field definitions . 40
12.5.1 General . 40
12.5.2 Multi byte fields . 40
12.5.3 Length field (L-Field) . 40
12.5.4 Control field (C-Field). 40
12.5.5 Manufacturer ID (M-field) . 42
12.5.6 Address (A-field) . 43
12.5.7 Cyclic redundancy check (CRC-field) . 43
12.5.8 Control information field (CI-field) . 43
12.6 Timing . 43
12.6.1 Timing for installation messages . 43
12.6.2 Synchronous transmissions of meter messages . 44
12.6.3 Access timing . 45
12.7 Repeated or duplicate messages . 47
12.8 Forward Error Correction (FEC) . 47
12.8.1 Overview . 47
12.8.2 Datagram structure. 47
12.8.3 FEC Algorithm . 48
13 Connection to higher protocol layers . 49
13.1 The Control Information Field (CI-field) . 49
13.2 CI –fields for the Extended Link Layer . 50
13.2.1 General . 50
13.2.2 CI-field = 8C . 51
h
13.2.3 CI-field = 8D . 51
h
13.2.4 CI-field = 8E . 51
h
13.2.5 CI-field = 8F . 52
h
13.2.6 CI-field = 86 . 52
h
13.2.7 Communication Control Field (CC-field) . 53
13.2.8 Access Number Field (ACC-field) . 55
13.2.9 Manufacturer ID 2 (M2-field) . 55
13.2.10 Address 2 (A2-field) . 55
3
---------------------- Page: 5 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
13.2.11 Session Number Field (SN-field) . 55
13.2.12 AES-128 Counter Mode Encryption . 56
13.2.13 Run Time Delay field (RTD-field) . 57
13.2.14 Reception Level field (RXL-field) . 57
13.2.15 Payload Checksum Field (PayloadCRC-field) . 59
13.3 CI-fields for the Transport Layer . 59
13.3.1 General . 59
13.3.2 Short Transport Layer . 59
13.3.3 Long Transport Layer . 60
14 Management functions for link control . 60
14.1 General . 60
14.2 Set Radio Parameters . 63
14.2.1 General . 63
14.2.2 Command . 63
14.2.3 Response . 67
14.3 Get Radio Parameters . 69
14.3.1 General . 69
14.3.2 Command . 69
14.3.3 Response . 69
14.4 Set limited radio parameters . 71
14.4.1 General . 71
14.4.2 Command . 71
14.4.3 Response . 72
14.5 Confirm Radio Parameters . 72
14.5.1 General . 72
14.5.2 Command . 73
14.5.3 Response: . 73
14.6 Set manufacturer specific parameters . 74
14.6.1 General . 74
14.6.2 Command . 74
14.6.3 Response . 75
Annex A (informative) Frequency allocation and band usage for the 868 MHz band . 76
Annex B (informative) Frequency allocation for the 169 MHz band . 77
B.1 Frequencies and allowed power levels . 77
B.2 Frequencies and allowed duty cycles . 77
Annex C (informative) Frame examples . 79
C.1 Example of a frame from a meter in mode S . 79
C.1.1 Conditions . 79
C.1.2 Block content . 79
C.1.3 Bit string . 80
C.2 Example of a frame from a meter in mode T1 . 80
C.2.1 Condition . 80
C.2.2 Block Content . 81
C.2.3 Bit string . 82
C.3 Example of a frame from a meter in mode C1 . 82
C.3.1 Conditions . 82
C.3.2 Block content . 83
C.3.3 Bit string . 83
Annex D (informative) Example of predictive reception of synchronous messages . 84
4
---------------------- Page: 6 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
Annex E (informative) Timing diagrams . 85
Annex F (informative) Counter Mode Flow . 99
Bibliography . 100
5
---------------------- Page: 7 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
European foreword
This document (prEN 13757-4:2017) has been prepared by Technical Committee CEN/TC 294
“Communication systems for meters”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 13757-4:2013.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
The main changes since EN 13757-4:2013 are as follows:
— referenced standards have been updated to the most recent versions;
— Mode N, in the 169 MHz band has been extended to cover more frequencies see Clause 10;
— new C-field function code (Send User Data - No reply) added see 12.5.4;
— optional Forward Error Correction in the Link Layer added see 12.8;
— CI field for selectable Extended Link Layer added see 13.2;
— management functions for link control added see Clause 14.
The standard is not affected by any of the requirements in Directive 2004/22/EC as it only covers the
basic transmission of information from the meter to an external entity. The standard ensures that data
transmitted cannot be modified without it being detected. Confidentiality, integrity and authenticity are
provided by the capabilities specified in other part of the EN 13757 series of standards. The standard
does not specify any of the metering capabilities of the meter nor the metrological capabilities of the
meter.
The standard enables encrypted transfer data either directly or as specified in other parts of the
EN 13757 series of standards. The encryption ensures the confidentiality of any personal data.
The standard provides capabilities of interoperability of meters as requested in M/441 which can be
used to improve the customer awareness of actual consumption.
6
---------------------- Page: 8 ----------------------
oSIST prEN 13757-4:2018
prEN 13757-4:2017 (E)
Introduction
This draft European Standard belongs to the EN 13757 series, which covers communication systems for
meters. EN 13757-1 contains generic descriptions and a communication protocol. EN 13757-2 contains
a physical and a link layer for twisted pair based Meter-Bus (M-Bus).
prEN 13757-3 describes the application layer protocols (often called M-Bus).
EN 13757-5 describes the wireless network used for repeating, relaying and routing for the different
modes of EN 13757-4.
EN 13757-6 describes a twisted pair local bus for short distance (Lo-Bus).
prEN 13757-7 describes transport and security services.
These upper M-Bus protocol layers can be used with various physical layers and with link layers and
network layers, which support the transmission of variable length binary transparent messages.
Frequently, the physical and link layers of EN 13757-2 (twisted pair) and EN 13757-4 (wireless) as well
as EN 13757-5 (wireless with routing function) or the alternatives described in EN 13757-1 are used.
The different parts of this standard are complemented by FprCEN/TR xxxxx that provides examples and
supplementary information related to prEN 13757-3 and prEN 13757-7.
These upper M-Bus protocol layers have been optimized for minimum
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.