Maintenance for lifts and escalators - Rules for maintenance instructions

This document specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and moving walks.
This document does not cover:
a)   instructions for the installation and the dismantling;
b)   any legal examinations and tests based on national regulations.
Existing installations are not covered by this document, but it can be taken as a reference.

Instandhaltung von Aufzügen und Fahrtreppen - Regeln für Instandhaltungsanweisungen

Maintenance des ascenseurs et des escaliers mécaniques - Règles pour les instructions de maintenance

Vzdrževanje dvigal (liftov) in tekočih stopnic - Pravila za navodila o vzdrževanju

General Information

Status
Not Published
Public Enquiry End Date
04-Apr-2017
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
17-Nov-2022
Due Date
22-Nov-2022
Completion Date
17-Nov-2022

Relations

Draft
oSIST prEN 13015:2017
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN 13015:2017
01-marec-2017
9]GUåHYDQMHGYLJDO OLIWRY LQWHNRþLKVWRSQLF3UDYLOD]DQDYRGLODRY]GUåHYDQMX
Maintenance for lifts and escalators - Rules for maintenance instructions
Instandhaltung von Aufzügen und Fahrtreppen - Regeln für Instandhaltungsanweisungen
Maintenance des ascenseurs et des escaliers mécaniques - Règles pour les instructions
de maintenance
Ta slovenski standard je istoveten z: prEN 13015
ICS:
91.140.90 'YLJDOD7HNRþHVWRSQLFH Lifts. Escalators
oSIST prEN 13015:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN 13015:2017
oSIST prEN 13015:2017
DRAFT
EUROPEAN STANDARD
prEN 13015
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2017
ICS 91.140.90 Will supersede EN 13015:2001+A1:2008
English Version
Maintenance for lifts and escalators - Rules for
maintenance instructions
Maintenance des ascenseurs et des escaliers
mécaniques - Règles pour les instructions de
maintenance
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 10.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13015:2017 E
worldwide for CEN national Members.

oSIST prEN 13015:2017
prEN 13015:2017 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Elaboration of maintenance instructions . 7
4.1 General . 7
4.2 Elements to be taken into account for the maintenance instructions . 7
4.3 Information to be included in the maintenance instructions . 8
4.3.1 General . 8
4.3.2 Information to the owner of the installation . 8
4.3.3 Information for the maintenance organization . 11
5 Risk assessment . 12
5.1 General . 12
5.2 Information for the maintenance organization . 13
6 Information to the owner for lift rescue operations . 14
7 Markings, signs, pictograms and written warnings . 14
8 Format of the maintenance instructions . 14
Annex A (informative) Typical examples of checks to be taken into account in maintenance
instructions . 16
A.1 Electric lifts . 16
A.2 Hydraulic lifts . 18
A.3 Escalators and moving walks . 20
Annex B (informative) Examples of elements to be taken into account in risk assessment
for maintenance operations . 21
Annex ZA (informative) Relationship between this European Standard and the Essential
Requirements of EU Directive 2006/42/EC on machinery . 24
Annex ZB (informative) Relationship between this European Standard and the Essential
Requirements of EC Directive 95/16/EC . 25
Bibliography . 26

oSIST prEN 13015:2017
prEN 13015:2017 (E)
European foreword
This document (prEN 13015:2017) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving work”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 13915:2001+A1:2008.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA and ZB, which is an integral part of this
document.
oSIST prEN 13015:2017
prEN 13015:2017 (E)
Introduction
This European Standard is a type C standard as stated in EN ISO 12100.
Only correct and preventative maintenance performed by a competent maintenance person in
conformity with the maintenance instructions can ensure the safe and intended functioning of an
installation.
oSIST prEN 13015:2017
prEN 13015:2017 (E)
1 Scope
This European Standard specifies the elements necessary for the preparation of the instructions for the
maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods
passenger lifts, accessible goods only lifts, service lifts, escalators and moving walks.
This European Standard does not cover:
a) instructions for the installation and the dismantling;
b) any legal examinations and tests based on national regulations.
Existing installations are not covered by this standard, but it can be taken as a reference.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 81-3, Safety rules for the construction and installation of lifts — Part 3: Electric and hydraulic service
lifts
EN 81-20:2014, Safety rules for the construction and installation of lifts - Lifts for the transport of persons
and goods - Part 20: Passenger and goods passenger lifts
EN 81-28, Safety rules for the construction and installation of lifts - Lifts for the transport of persons and
goods - Part 28: Remote alarm on passenger and goods passenger lifts
EN 81-31, Safety rules for the construction and installation of lifts - Lifts for the transport of goods only -
Part 31: Accessible goods only lifts
EN 81-50, Safety rules for the construction and installation of lifts - Examinations and tests - Part 50:
Design rules, calculations, examinations and tests of lift components
EN 115-1, Safety rules for the construction and installation of escalators and moving walks — Part
1:Construction and Installation
EN ISO 12100:2011, Safety of machinery —- General principles for design — Risk assessment and risk
reduction
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 81-20, EN 81-50, EN 81-3,
EN 81-31, EN 81-28, EN 115-1, EN ISO 12100 and the following apply.
3.1
maintenance
all the necessary operations to ensure the safe and intended functioning of the installation and its
components after the completion of the installation and throughout its life cycle
Note 1 to entry: For the purpose of this standard and of “maintenance”, the definition of 3.1 in EN 81–20:2014,
3.30 is clarified as follows:
Maintenance includes:
oSIST prEN 13015:2017
prEN 13015:2017 (E)
a) lubrication, cleaning, etc.;
However, the following cleaning operations can be not considered as maintenance:
1) cleaning of the external parts of the well;
2) cleaning of the external parts of the escalator or passenger conveyor;
3) cleaning of the inside of the car.
b) checks;
c) rescue operations;
d) the operations of setting and adjustment;
e) repair or changing of components which may occur due to wear or tear and do not affect the
characteristics of the installation.
The following are not considered as maintenance operations:
f) changing of a major component such as the machine, the car, the control panel, etc., or safety
component such as safety gear, etc., even if the characteristics of the new component are the same as
the original;
g) replacement of the installation;
h) modernization of the installation, including the changing of any characteristic of the installation (such
as speed, load, etc.);
i) rescue operations carried out by Fire Brigades.
3.2
maintenance organization
company or part of company where competent maintenance person(s) carry out maintenance
operations on behalf of the owner of the installation
3.3
competent person
person, suitably trained, qualified by knowledge and practical experience, provided with necessary
instructions to safely carry out the required operations for maintaining or inspecting the equipment, or
rescuing users
Note 1 to entry: National Regulation may require certification of competence.
3.4
manufacturer
natural or legal person who takes responsibility for the design, manufacture either of safety
components for lifts or of machinery (accessible goods only lift, service lift, escalator and moving walk)
3.5
installer
see EN 81-20:2014, 3.20
oSIST prEN 13015:2017
prEN 13015:2017 (E)
3.6
installation
completely installed passenger lift, good passenger lift, accessible goods only lift, service lift, escalator
or moving walk
3.7
owner of the installation
natural or legal person who has the power of disposal of the installation and takes the responsibility for
its operation and use
3.8
rescue operations
see EN 81-20:2014, 3.46
4 Elaboration of maintenance instructions
4.1 General
The installations covered by this European Standard shall be maintained in accordance with the
installer's/manufacturer’s instructions. To this effect, regular maintenance of the installation shall be
carried out, to ensure, in particular, the safety of the installation. The safety of an installation shall take
into account the ability to be maintained without causing injury or damage to health.
Regular maintenance of the installation shall be carried out to ensure the reliability of the installation.
The access and the associated environment shall be maintained in good working order in accordance
with the installer/manufacturer’s instructions.
In order that the aim of the maintenance instructions can be achieved, they shall be formulated so that
they can be clearly and easily understood by competent maintenance persons.
The competence of the maintenance person within the maintenance organization shall be continuously
updated.
The owner of the installation should be informed that the qualification of the maintenance organization
is in conformity with the regulations applicable in the country in which the installation operates; if no
regulations exist, the qualification can be ensured by a certified quality system in accordance with
EN ISO 9001 supplemented if necessary to take into account the specific features of the installation.
The installer/manufacturer shall provide maintenance instructions intended for the owner of the
installation (see 4.3.2) including information intended for the maintenance organization (see 4.3.3).
4.2 Elements to be taken into account for the maintenance instructions
When preparing the content of the maintenance instructions the following elements shall be taken into
account:
a) the specifications and the intended use of the installation (type of installation, performance, type of
goods to be transported, type of users, etc.);
b) the environment in which the installation and its components are installed (weather conditions,
vandalism, etc.);
c) any restriction of use;
d) the result of the risk assessment (see Clause 5) for every working area and for every task to be
undertaken;
oSIST prEN 13015:2017
prEN 13015:2017 (E)
e) the specific maintenance instructions provided by the manufacturer of safety components;
f) in case of components other than safety components, where maintenance is necessary, the
maintenance instructions provided by the manufacturer of these components.
4.3 Information to be included in the maintenance instructions
4.3.1 General
The maintenance instructions shall contain information relating to the tasks of the owner and
respectively the maintenance organization.
4.3.2 Information to the owner of the installation
The information relating to the tasks of the owner of the installation shall include the following:
4.3.2.1 The need for the owner to keep the installation in a safe operating condition. To fulfil this
the owner shall use a maintenance organization complying with the requirements of the Standard.
It is recommended to inform the owner of the installation about the need to use a maintenance
organization with adequate and proper insurance cover provided by an insurance company.
4.3.2.2 The need for the owner to take care of any National regulations and other requirements,
where relevant, and their implications on maintenance.
4.3.2.3 The need for planned maintenance to be carried out by a maintenance organization, at the
latest when the installation is put into service or if the installation is to remain unused for a long period
of time before first being put into service.
4.3.2.4 The importance for the owner of the installation to have the same maintenance organization
in the case of several installations having common well/spaces and/or machine room.
4.3.2.5 The need for the owner of a passenger-/goods passenger lift to keep, as described in EN 81-
28, the two-way means of communication efficient and linked to a 24 h rescue service for the whole of
the time that the installation can be used.
4.3.2.6 The need for the owner to remove the passenger-/goods passenger lift from service when
the two-way means of communication is out of order.
4.3.2.7 The need for the owner to put the installation out of service in case of dangerous situations.
4.3.2.8 The need for the owner of the installation to inform the maintenance organization:
a) immediately about any perceived abnormal operation of the installation or abnormal change in its
direct environment;
b) immediately after putting the installation out of service in the case of a dangerous situation;
c) after any rescue intervention by their authorized and instructed person(s) (see Clause 6);
d) before any modification related to the installation and/or its environment or use;
The owner of the installation should obtain from the company carrying out the relevant modification
the maintenance instructions for the maintenance organization.
oSIST prEN 13015:2017
prEN 13015:2017 (E)
e) before any authorized third party inspection or works other than maintenance works are carried
out on the installation;
f) before taking the installation out of service for a prolonged period of time;
g) before putting the installation back into service after a prolonged period of non-operating time.
4.3.2.9 The need for the owner of the installation to take into consideration the consequences of the
risk assessment carried out by the maintenance organization (see 4.3.3.4 and 5.1).
4.3.2.10 The need for the owner of the installation to make sure that the risk assessment for
maintenance is carried out:
a) if the maintenance organization is replaced;
b) if the use of the building and/or the installation changes;
c) after a major modification of the installation or of the building;
d) if it is the case, after an accident involving the installation.
4.3.2.11 The need for the building owner to ensure, through a risk assessment, that:
a) their premises are safe and free from risk to health as far as is practicable. This includes access to
the premises and installation equipment, and articles or substances used according to national
regulations;
b) the persons using the premises are informed about any remaining risks;
c) any action to be done as a consequence of his risk assessment is carried out.
Regarding the access ways to areas reserved to maintenance persons, the need for the owner of the
installation to inform the maintenance organization, in particular about:
1) the access ways to be used and fire evacuating procedures from the building;
2) the place where the keys of the reserved areas can be found;
3) if necessary, the persons who shall accompany the maintenance persons to the installation;
4) if necessary, personal protective equipment to be used in the access ways, and, possibly, where this
equipment can be found.
The information shall be made available also on site to the maintenance organization.
4.3.2.12 The need for the owner of the installation to ensure that the name and the telephone
number of the maintenance organization are always available to the user of the installation,
permanently affixed and clearly visible.
4.3.2.13 The need for the owner of the installation to ensure that the keys of machine and pulley
room doors (trap doors) and of inspection and emergency doors (trap doors) are permanently available
in the building and are used only by persons authorized to gain access.
4.3.2.14 The need for the owner of the installation to provide, in all circumstances, safe access to the
building and to the installation for the maintenance organization involved in the rescue of persons.
oSIST prEN 13015:2017
prEN 13015:2017 (E)
4.3.2.15 The need for the owner of the installation to keep the access to working areas and working
rooms safe and free for the maintenance persons and to inform the maintenance organization about any
hazard or change in the workplace and/or the access ways (lighting, obstructions, ground conditions,
etc.).
4.3.2.16 In addition to those examinations and tests which the owner of the installation entrusts to
the maintenance organization, the need for the owner to carry out periodically, in their own interests,
the following:
a) for lifts
A full ascent and descent to assess any changes in the quality of the ride or damage to the
equipment. Typical items to be checked to ensure that they are in place, undamaged and
functioning correctly are:
— landing doors and bottom door tracks;
— stopping accuracy;
— indicators that are not located in a reserved area;
— landing push controls;
— car push controls;
— door open controls;
— two-way means of communication in the car which provides permanent contact with a rescue
service;
— normal car lighting;
— door reversal device;
— safety signs/pictograms.
For goods only and service lifts the checks to be carried out are the same, when relevant.
b) for escalators/moving walks
A full travel in both directions, when they exist, to assess any changes in the quality of the ride or
damage to the equipment.
Typical items to be checked to ensure that they are in place, undamaged and functioning correctly
are:
— all lighting and indicators;
— emergency stopping device;
— hand rails;
— skirting/deflector devices;
oSIST prEN 13015:2017
prEN 13015:2017 (E)
— combs ;
— safety signs/pictograms;
— approximation of speed between handrail and steps/pallets;
— steps/pallets;
— balustrade and panels;
— head guard and decking;
— safe and unobstructed access to entry and exit areas.
4.3.3 Information for the maintenance organization
The information relating to the tasks of the maintenance organization shall include the following:
4.3.3.1 The need to carry out the work of maintenance in conformity with the maintenance
instructions and based on systematic maintenance checks.
After these checks, the maintenance organization shall decide in conformity with the maintenance
instructions what is required to be done.
A list of typical examples of maintenance checks to maintain the installation is shown in Annex A.
NOTE Due to the fact that the components can be different in design and operation, it is therefore not
possible to give specific guidelines in this standard.
4.3.3.2 The need to update the original maintenance instructions if the installation changes its
intended use and/or the environmental conditions existing on the completion of the installation.
The maintenance organization should be provided by the owner of the installation with the relevant