Abstract

This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport.
This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids.
This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc.
NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985.
NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.

Status
Not Published
Public Enquiry End Date
02-Apr-2025
Technical Committee
TLP - Pressure vessels
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
02-Oct-2026
Due Date
20-Nov-2026
Completion Date
10-Nov-2026

Buy Documents

Draft

oSIST prEN ISO 20421-1:2025 - BARVE

English language (129 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN ISO 20421-1:2026 is a SIST standard for large transportable vacuum-insulated cryogenic vessels. It specifies requirements for the design, fabrication, inspection and testing of vessels above 450 l used on one or more modes of transport, for cryogenic fluids. The standard is aimed at manufacturers, inspectors, operators, and anyone specifying or approving fixed tanks, demountable tanks, or portable tanks.

What does kSIST FprEN ISO 20421-1:2026 specify?

kSIST FprEN ISO 20421-1:2026 covers the complete technical basis for large transportable vacuum-insulated cryogenic vessels: what they are, how they are designed, how they are made, how they are inspected, and how they are marked and accepted. It applies to vessels for the cryogenic fluids defined in Clause 3 and excludes vessels designed for toxic fluids, as well as general vehicle equipment such as running gear, brakes, and lighting.

The standard is organized into clauses on scope, normative references, terms and definitions, symbols, general requirements, mechanical loads, chemical effects, thermal conditions, materials, design, fabrication, inspection and testing, marking and labelling, final acceptance, periodic inspection, and documentation.

It also uses annexes for special methods and special cases.

AnnexWhat it covers
Annex AExamples of tank plates for complete tanks and inner vessels
Annex BElastic stress analysis
Annex CSpecific requirements for vessels constructed of 9 % Ni steels
Annex DPressure strengthening
Annex EWeld details in common cryogenic-vessel use
Annex FOuter-jacket relief devices
Annex HAlternative calculation methods for external pressure on cylinders and stiffening rings
Annex IAlternative methods for opening reinforcement
Annex JEquivalent thickness methods
Annex KRefrigerated liquefied gases

What are the key requirements of kSIST FprEN ISO 20421-1:2026?

kSIST FprEN ISO 20421-1:2026 sets requirements that make the vessel safe for transport, filling, operation, inspection, and acceptance. The main idea is that the complete assembly - inner vessel, outer jacket, valves, service equipment, and structural parts - has to work as a transportable pressure vessel, not just as a tank shell.

Design basis, loads, and operating safety

Clause 5.1 requires the vessel to withstand the mechanical and thermal loads, and the chemical effects, encountered during pressure test and normal operation. In practice, this means the design has to be checked for service conditions, not only for a one-time test.

Clause 6.1 allows three ways to validate resistance to mechanical loads: calculation, calculation with pressure strengthening where allowed, or calculation supplemented by experimental methods. Clause 6.2 defines the pressure-test load calculation and includes an allowance for external vacuum. That matters because the vessel must survive both internal pressure and the vacuum-jacket conditions that occur in service.

Clause 5.2 says valves, pressure-relief devices, and similar equipment have to be configured and installed so the vessel can be operated safely, and the number of openings in the inner vessel should be kept to a minimum. This reduces leakage paths and simplifies maintenance.

Materials and compatibility

Clause 7 states that chemical action on the inner surfaces in contact with cryogenic fluids can be neglected under the stated conditions, and that corrosion allowance is not required on surfaces in contact with the operating fluid or exposed to the vacuum interspace. The outer surfaces exposed to atmosphere still need a material and protection system suitable for the intended environment.

Clause 9.1 requires materials in contact with cryogenic fluids to comply with ISO 21010, and low-temperature materials to meet the relevant toughness requirements in ISO 21028-1 and ISO 21028-2. Clause 9.2 requires inspection documentation for materials. In practice, buyers and manufacturers need traceable material evidence, not just nominal grade designations.

Design details and calculation methods

Clause 10 sets out the core design rules for pressure, openings, cones, flat ends, attachments, piping, valves, insulation, filling degree, and electrical continuity. It covers internal and external pressure, fatigue, pressure relief, and the loads on supports and fastening points. That matters because transport tanks see more than steady internal pressure - they also see handling, lifting, vibration, and thermal cycling.

Clause 10.3 provides detailed calculation rules for shells, spheres, dished ends, cones, flat ends, and openings. Annex H gives two accepted methods for external-pressure calculations, and Annex I gives two accepted methods for opening reinforcement; both are stated to give comparable results and are equally accepted. Annex B gives rules for elastic stress analysis, including stress categories and allowable stress limits when that approach is used.

Clause 10.3.7 points to Annex B or ASME VIII-2 for terminology and acceptable stress limits in elastic stress analysis. That gives designers a defined route when they use analysis instead of only direct formulae.

Fabrication, welding, and tolerances

Clause 11 covers cutting, cold forming, hot forming, tolerances, welding, and non-welded joints. Thermally cut material has to be dressed back, and welding procedures and personnel have to be qualified. For non-welded pressure-retaining joints, the standard requires established procedures and qualified operators in the same way as for welding.

Clause 11.5 sets fabrication tolerances for items such as circumference, out-of-roundness, and axis straightness. Clause 11.6 points to Annex E for specific weld details, which is useful because weld geometry and access affect both fatigue life and inspection.

Inspection, testing, marking, and documentation

Clause 12 requires a quality plan, inspection stages during manufacture, production control test plates, non-destructive testing, rectification, pressure testing, and leakproofness tests. Repaired welds have to be re-examined to the original acceptance standard, and every inner vessel has to pass a pressure test and demonstrate leak tightness. For a buyer or inspector, this means the standard is not only a design document - it also defines the verification route before release.

Clause 13 requires marking and labelling on a corrosion-resistant metal plate permanently attached to the outer jacket, and Annex A gives examples of the tank plates. Clauses 14 and 15 cover final acceptance and periodic inspection, and Clause 16 defines the documentation to be delivered to the owner, including conformity evidence, vessel description, a fluid list with net mass, and an operating manual.

Special cases

Annex C gives extra rules for 9 % Ni steels, including design and inspection points specific to that material family. Annex D covers pressure-strengthened vessels, where the vessel is intentionally pressurised after completion to raise its proof strength. Annex F covers relief devices for the outer jacket, which are needed to prevent accidental pressure build-up in the vacuum space.

What terms does kSIST FprEN ISO 20421-1:2026 define?

  • cryogenic fluid - A refrigerated liquefied gas, including totally evaporated liquids and supercritical fluids; in this document it refers to the non-toxic refrigerated gases and gas mixtures listed in Table K.1.
  • large transportable cryogenic vessel - A thermally insulated vessel of more than 450 l intended for transport of one or more cryogenic fluids, complete with the inner vessel, outer jacket, valves, service equipment, and structural parts.
  • inner vessel - The pressure vessel that contains the cryogenic fluid to be transported.
  • outer jacket - The gas-tight enclosure around the inner vessel that enables the vacuum to be established.
  • maximum allowable working pressure (MAWP) - The maximum gauge pressure permitted at the top of the vessel in normal operating position.
  • pressure-strengthened vessel - A vessel that is deliberately pressurised after completion so its wall thickness is based on the strengthening pressure rather than the conventional design stress value.
  • leakproofness test - A gas test of the shell and service equipment at an effective internal pressure of at least 90 % of MAWP and not greater than the design pressure.
  • demountable tank - A large transportable vessel that is not permanently attached to a vehicle and is designed to be lifted only when empty.

Who uses kSIST FprEN ISO 20421-1:2026?

kSIST FprEN ISO 20421-1:2026 is used by manufacturers of cryogenic tanks, design engineers, welding engineers, inspection bodies, and quality managers. It is also used by owners, buyers, and operators who need to define what has to be built, tested, marked, documented, and periodically inspected.

In practice, the standard supports:

  • tank and vessel design
  • welding procedure qualification and welder qualification
  • non-destructive testing planning and acceptance
  • pressure testing and leakproofness verification
  • marking, acceptance, and periodic inspection
  • documentation handover to the owner or operator

It is relevant to transport equipment such as fixed tanks, demountable tanks, portable tanks, tank containers, road tankers, and tank swap bodies.

Which standards are used with kSIST FprEN ISO 20421-1:2026?

StandardWhat it contributes
ISO 20421-2Operational requirements and periodic inspection for these vessels
ISO 23208Cleanliness for cryogenic service
ISO 21010Gas/material compatibility
ISO 21011Valves for cryogenic service
ISO 21028-1 / ISO 21028-2Toughness requirements at cryogenic temperature
ISO 21013-3Sizing and capacity determination for pressure-relief accessories
ISO 3834-2Quality requirements for fusion welding
ISO 9606-1 / ISO 9606-2Welder qualification testing
ISO 9712Qualification and certification of NDT personnel
ISO 15613 / ISO 15614-1 / ISO 15614-2Welding procedure qualification
ISO 17635 / ISO 17637General NDT rules and visual testing of welds
ISO 5817 / ISO 10042Imperfection quality levels for welded joints
ISO 10474Inspection documents for steel and steel products
ISO 10675-1Radiographic acceptance levels for welds
ASME VIII-2Alternative rules and stress-analysis terminology
EN 13445-3Alternative design rules for unfired pressure vessels

What does the kSIST FprEN ISO 20421-1:2026 document contain?

kSIST FprEN ISO 20421-1:2026 contains symbol definitions, design formulae, and detailed calculation methods for pressure parts such as shells, spheres, cones, flat ends, openings, and reinforcement. It also includes figures that show opening factors, pad reinforcement, nozzle reinforcement, and stiffening-ring arrangements.

The annexes add practical material and construction content: tank-plate examples in Annex A, elastic stress analysis in Annex B, special provisions for 9 % Ni steels in Annex C, pressure strengthening in Annex D, common weld details in Annex E, and outer-jacket relief devices in Annex F. Annexes H, I, and J provide alternative calculation methods for external pressure, opening reinforcement, and equivalent thickness.

Annex K gives the list of refrigerated liquefied gases used by the document, organized by classification group.

Relations

Effective Date
04-Oct-2023
Effective Date
04-Oct-2023

Buy Documents

Draft

oSIST prEN ISO 20421-1:2025 - BARVE

English language (129 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Institut za varilstvo d.o.o. (Welding Institute)

Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN ISO 20421-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Cryogenic vessels - Large transportable vacuum-insulated vessels - Part 1: Design, fabrication, inspection and testing (ISO/FDIS 20421-1:2026)". This standard covers: This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport. This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids. This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.

This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport. This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids. This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.

kSIST FprEN ISO 20421-1:2026 is classified under the following ICS (International Classification for Standards) categories: 23.020.40 - Cryogenic vessels. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN ISO 20421-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 13530-1:2002, SIST EN 13530-2:2003. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN ISO 20421-1:2026 is associated with the following European legislation: EU Directives/Regulations: 2008/68/EC; Standardization Mandates: M/TDG. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN ISO 20421-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 cryogenic fluid
  • 3.2 large transportable cryogenic vessel
  • 3.3 insulation
  • 3.4 inner vessel
  • 3.5 outer jacket
  • 3.6 normal operation
  • 3.7 handling load
  • 3.8 piping system
  • 3.9 service equipment
  • 3.10 manufacturer
  • 3.11 gross volume
  • 3.12 tare mass
  • 3.13 net volume
  • 3.14 net mass
  • 3.15 gross mass
  • 3.16 pressure
  • 3.17 fixed tank
  • 3.18 demountable tank
  • 3.19 portable tank
  • 3.20 maximum allowable working pressure
  • 3.21 relief plate
  • 3.22 bursting disc device
  • 3.23 pressure-strengthened vessel
  • 3.24 residual elongation
  • 3.25 leakproofness test
  • 4 Symbols
  • 5 General requirements
  • 5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting
  • 6 Mechanical loads
  • 6.1 General
  • 6.2 Load during the pressure test
  • 7 Chemical effects
  • 8 Thermal conditions
  • 9 Materials
  • 9.1 Selection of materials
  • 9.2 Inspection documentation
  • 10 Design
  • 10.1 Design options
  • 10.2 Common design requirements
  • 10.3 Design by calculation
  • 2. Cylindrical part: h ≥ s
  • 11 Fabrication
  • 11.1 General
  • 11.2 Cutting
  • 11.3 Cold forming
  • 11.4 Hot forming
  • 11.5 Manufacturing tolerances
  • 11.6 Welding
  • 11.7 Non-welded joints
  • 12 Inspection and testing
  • 12.1 Quality plan
  • 12.2 Production control test plates
  • 12.3 Non-destructive testing
  • 12.4 Rectification
  • 12.5 Pressure testing
  • 13 Marking and labelling
  • 14 Final acceptance test
  • 15 Periodic inspection
  • 16 Documentation
  • Annex A
  • 2 Approval number given by the competent authority or body designated by this authority
  • 15 Month and year of the pressure test of the inner vessel
  • 16 Stamp of the inspector who witnessed the pressure test
  • Annex B
  • Annex C
  • Annex D
  • 1 T (at T=20 °C) R ≥ σ ; A ≥ 25 %
  • 3 IW (at T ) 40 J/cm (0,38 mm)
  • Annex E
  • Annex F
  • Annex G
  • Annex H
  • 10 × E
  • Annex I
  • 10 Aσ 2 S
  • 3 Area available in inward nozzle; use smaller value

Introduction

[1] This document has been written so that it is suitable to be referenced in the UN Model Regulations . This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc., for which the relevant standards/regulations apply.

oSIST prEN ISO 20421-1:2025 DRAFT International Standard ISO/DIS 20421-1:2025(en) Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1:

Design, fabrication, inspection and testing

1 Scope

This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport.

This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids.

This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3834-2, Quality requirements for fusion welding of metallic materials — Part 2: Comprehensive quality requirements ISO 4126-2, Safety devices for protection against excessive pressure — Part 2: Bursting disc safety devices ISO 5817, Welding — Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) — Quality levels for imperfections ISO 9606-1, Qualification testing of welders — Fusion welding — Part 1: Steels ISO 9606-2, Qualification test of welders — Fusion welding — Part 2: Aluminium and aluminium alloys ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel ISO 10042, Welding — Arc-welded joints in aluminium and its alloys — Quality levels for imperfections ISO 10474:2013, Steel and steel products — Inspection documents ISO 10675-1, Non-destructive testing of welds — Acceptance levels for radiographic testing — Part 1: Steel, nickel, titanium and their alloys ISO 14732, Welding personnel — Qualification testing of welding operators and weld setters for mechanized and automatic welding of metallic materials

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en) ISO 15613, Specification and qualification of welding procedures for metallic materials — Qualification based on pre-production welding test ISO 15614-1, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys ISO 15614-2, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 2: Arc welding of aluminium and its alloys ISO 17635, Non-destructive testing of welds — General rules for metallic materials ISO 17637, Non-destructive testing of welds — Visual testing of fusion-welded joints ISO 20421-2, Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 2: Operational requirements ISO 21010, Cryogenic vessels — Gas/material compatibility ISO 21011, Cryogenic vessels — Valves for cryogenic service ISO 21028-1, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 1:

Temperatures below -80 degrees C ISO 21028-2, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 2:

Temperatures between -80 degrees C and -20 degrees C ISO 21013-3, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 3: Sizing and capacity determination ISO 23208, Cryogenic vessels — Cleanliness for cryogenic service ASME VIII-2, Rules for construction of pressure vessels, Division 2, Alternative Rules EN 13445-3, Unfired pressure vessels — Part 3: Design

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 cryogenic fluid

refrigerated liquefied gas gas which is partially liquid because of its low temperature (see Table K.1) Note 1 to entry: This includes totally evaporated liquids and supercritical fluids. Note 2 to entry: In the context of this document, the refrigerated but non-toxic gases and gas mixtures given in Table K.1 are referred to as cryogenic fluids.

3.2 large transportable cryogenic vessel

tank thermally insulated vessel of more than 450 l intended for the transport of one or more cryogenic fluids (3.1), consisting of an inner vessel (3.4), an outer jacket (3.5), all of the valves and service equipment (3.9) together with the structural parts Note 1 to entry: The large transportable cryogenic vessel comprises a complete assembly that is ready for service.

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en)

3.3 insulation

vacuum interspace between the inner vessel (3.4) and the outer jacket (3.5) Note 1 to entry: The space may or may not be filled with material to reduce the heat transfer between the inner vessel and the outer jacket.

3.4 inner vessel

pressure (3.16) vessel intended to contain the cryogenic fluid (3.1) to be transported

3.5 outer jacket

gas-tight enclosure which contains the inner vessel (3.4) and enables the vacuum to be established

3.6 normal operation

intended operation of the vessel at a pressure (3.16) not greater than the maximum allowable working pressure including the handling loads (3.7)

3.7 handling load

load exerted on the transportable cryogenic vessel in all normal conditions of transport including loading, unloading, moving and lifting

3.8 piping system

all pipes, tubes and associated components which can come in contact with cryogenic fluids (3.1) including valves, fittings, pressure-relief devices and their supports

3.9 service equipment

measuring instruments and filling, discharge, venting, safety, heating, cooling and insulating devices including any equipment for storing cooling fluids

3.10 manufacturer

<large transportable cryogenic vessel> company that carries out the final assembly, including the final acceptance test, of the large transportable cryogenic vessel (3.2)

3.11 gross volume

<of the inner vessel> internal volume of the inner vessel (3.4), excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)

3.12 tare mass

mass of the empty large transportable cryogenic vessel (3.2)

3.13 net volume

volume of the inner vessel (3.4), below the inlet to the relief devices, excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)

3.14 net mass

maximum allowable mass of the cryogenic fluid (3.1) which may be filled Note 1 to entry: The maximum allowable mass is equal to the mass of the cryogenic liquid occupying 98 % of the net volume (3.13)of the inner vessel (3.4) under conditions of incipient opening of the relief device with the vessel in a level attitude and the mass of the gas at the same conditions in the remaining volume of the inner vessel.

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en) Note 2 to entry: Cryogenic liquid helium can occupy 100 % of the volume of the inner vessel at any pressure (3.16).

3.15 gross mass

sum of tare mass (3.12) plus net mass (3.14)

3.16 pressure

gauge pressure pressure relative to atmospheric pressure

3.17 fixed tank

tank vehicle large transportable vessel permanently attached to a vehicle or to units of running gear

3.18 demountable tank

large transportable vessel non-permanently attached to a vehicle Note 1 to entry: When attached to the carrier vehicle, the demountable tank meets the requirements prescribed for a fixed tank. It is designed to be lifted only when empty.

3.19 portable tank

a thermally insulated tank having a capacity of more than 450 litres fitted with service equipment (3.9) and structural equipment necessary for the transport of refrigerated liquefied gases Note 1 to entry: It can be lifted full and loaded and discharged without removal of structural element. Note 2 to entry: The list of the refrigerated liquefied gases is available in Annex K.

3.20 maximum allowable working pressure

ps maximum gauge pressure (3.16) permissible at the top of the vessel in its normal operating position

3.21 relief plate

relief plug plate or plug retained by atmospheric pressure (3.16) which allows relief of excess internal pressure, generally from the vacuum jacket

3.22 bursting disc device

non-reclosing pressure-relief device ruptured by differential pressure (3.16) Note 1 to entry: It is the complete assembly of installed components including the bursting disc holder, where appropriate.

3.23 pressure-strengthened vessel

pressure (3.16) vessel which has been subjected to a calculated and controlled internal pressure (strengthening pressure) after completion, the wall thickness of which is calculated on the basis of the stress at the strengthening pressure and not on the basis of the conventional design stress value of the material used Note 1 to entry: Pressure (3.16) vessels made from solution heat-treated material are subject to a controlled plastic deformation during the strengthening operation as its yield point is raised. Pressure vessels made from work-hardened material are subject to little or no plastic deformation.

3.24 residual elongation

original elongation of the steel minus the elongation created by the cold-forming deformation

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en)

3.25 leakproofness test

test using gas subjecting the shell and its service equipment (3.9), to an effective internal pressure (3.16) not less than 90 % of the MAWP but not greater than the design pressure

4 Symbols

Symbol Definition Unit b width of pad, ring or shell reinforcement mm c allowance for corrosion mm d diameter of opening mm

d outside diameter of tube or nozzle mm a f narrow side of rectangular or elliptical plate mm h thickness of pad reinforcement mm l cone length between effective stiffenings (see Figure 5) mm

l ligament (web) between two nozzles mm l l′ buckling length mm b, b l length of nozzle reinforcement outstanding mm s n number of lobes — p design pressure as defined in 10.3.2.2 — p calculation pressure as defined in 10.2.3.2.1 a) bar (or MPa)

p allowable external pressure limited by elastic buckling bar (or MPa) e p strengthening pressure bar (or MPa) k p liquid pressure bar (or MPa) L p allowable external pressure limited by plastic deformation bar (or MPa) p p maximum allowable gauge pressure bar (or MPa) s p test pressure (see 6.2) bar (or MPa) T r radius, e.g. inside knuckle radius of dished end and cones mm s minimum thickness mm s required wall thickness at opening edge mm A s actual wall thickness mm e s required wall thickness outside corner area mm g s thickness of nozzle reinforcement in stand mm n s wall thickness of nozzle mm S s required wall thickness within corner area mm

t in this context, centre-to-centre distance between two nozzles mm x (decay-length zone) distance over which governing stress is assumed to act mm x characteristic lengths (i = 1,2,3) to define corner area [Figure 7 a) and mm

Figure 7 b) and 10.3.6.5.4] η factor indicative of the utilization of the permissible design stress in joints or — factor allowing for weakenings

A cross-sectional area of reinforcing element mm C, β design factors — D shell diameter mm D outside diameter, e.g. of a cylindrical shell mm a D outside diameter of connected cylinder (see Figure 7) mm a1 D outside diameter at effective stiffening (see Figure 9) mm a2 D internal diameter, e.g. of a cylindrical shell mm

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en) Symbol Definition Unit D design diameter (see Figure 7) mm k D shell diameter at nozzle (see Figure 8) mm s

E Young’s modulus N/mm

I moment of inertia of reinforcing element mm

R minimum guaranteed yield stress or 0,2 % proof stress at 20 °C (1 % proof N/mm e stress for austenitic steel)

R minimum guaranteed tensile strength at 20 °C N/mm m

K material property used for design (see 10.3.2.3) N/mm

K material property at temperature T in °C (e.g. K for material property at 20 °C N/mm T 20 (see 10.3.2.3.2) R radius of curvature, e.g. inside crown radius of dished end mm S safety factor at design pressure, in relation with R — e S safety factor against elastic buckling at design pressure — k S safety factor against plastic deformation — p Z auxiliary value — v Poisson’s ratio — u out of roundness (see 11.5.5.2) — φ cone angle °

5 General requirements

5.1 The large transportable cryogenic vessel shall safely withstand the mechanical and thermal loads and the chemical effects encountered during pressure test and normal operation. These requirements are deemed to be satisfied if Clauses 6 to 12 are fulfilled. The vessel shall be marked in accordance with Clause 13, tested in accordance with Clause 14 and operated in accordance with ISO 20421-2. 5.2 Large transportable cryogenic vessels shall be equipped with valves, pressure-relief devices, etc., configured and installed in such a way that the vessel can be operated safely. The number of openings in the inner vessel for this equipment shall be kept to a minimum.

5.3 The large transportable cryogenic vessel shall be clean for the intended service in accordance with ISO 23208.

5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting

documentation (including that from his subcontractors, if any), for a required period (e.g. product liability). In addition, the manufacturer shall retain all supporting and background documentation (including that from his subcontractors, if any) which establishes that the vessel conforms to this document.

6 Mechanical loads

6.1 General

The large transportable cryogenic vessel shall resist the mechanical loads mentioned in 10.2.3 without such deformation which can affect safety and which can lead to leakage. This requirement can be validated by:

  • the calculation;
  • the calculation and pressure-strengthening method, if allowed;
  • the calculation and experimental method.

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en)

6.2 Load during the pressure test

The load exerted during the pressure test shall be calculated with Formula (1):

pp≥+13,b1 ar or pp≥+1,30,1 MPa (1)

TS TS where p is the test pressure (in bar); T p is the maximum allowable pressure (in bar); S +1 is the allowance for external vacuum (in bar).

+0,1 is the allowance for external vacuum (in MPa).

7 Chemical effects

Due to operating temperatures and the materials of construction, the possibility of chemical action on the inner surfaces in contact with the cryogenic fluids can be neglected. Due to the fact that the inner vessel is inside an evacuated outer jacket, neither external corrosion of the inner vessel, nor corrosion on the inner surfaces of the outer jacket will occur. Therefore, inspection openings are not required in the inner vessel or the outer jacket.

Corrosion allowance is also not required on surfaces in contact with the operating fluid or exposed to the vacuum interspace between the inner vessel and the outer jacket. The material and the protection for the surfaces exposed to the atmosphere shall be suitable for intended use (e.g. resistant to industrial and marine atmospheres).

8 Thermal conditions

The following thermal conditions shall be taken into account:

For the inner vessel and its associated equipment the full range of temperature expected. For the outer jacket and equipment thereof (other than equipment covered in Clause 7):

  • a minimum working temperature of −20 °C;
  • a maximum working temperature of 50 °C.

NOTE 1 Some locations require lower minimum working temperature e.g. –40 °C and/or higher maximum working temperature, e.g. +65 °C.

NOTE 2 This does not apply if the jacket is designed for a lower temperature to be marked on the nameplate.

9 Materials

9.1 Selection of materials

9.1.1 Materials which are, or can be, in contact with cryogenic fluids shall be in accordance with ISO 21010.

9.1.2 Materials used at low temperatures shall follow the requirements of the relevant parts of

ISO 21028-1 and ISO 21028-2; for non-metallic materials, low-temperature suitability shall be validated by an experimental method, taking into account operating temperatures.

oSIST prEN ISO 20421-1:2025 ISO/DIS 20421-1:2025(en) 9.1.3 The base materials, listed in Annex G, subject to meeting the extra requirements given in Clauses 5 to 16, are suitable for and may be employed in the manufacture of the cryogenic vessels, in conformance with this document.

9.2 Inspection documentation

9.2.1 The material according to ISO 21028-1 and ISO 21028-2 shall be declared by an inspection certificate 3.1 in accordance with ISO 10474:2013, 5.1.

9.2.2 The material manufactured to a recognized International Standard shall meet the testing

requirements of ISO 21028-1 and ISO 21028-2 and shall be declared by an inspection certificate 3.1 in accordance with ISO 10474:2013, 5.1.

9.2.3 The delivery of material which is not manufactured to a recognized International Standard shall be guaranteed by an inspection certificate 3.2 in accordance with ISO 10474:2013, 5.2 confirming that the material fulfils the requirements in 9.1. The material manufacturer shall follow a recognized International Standard for processing and establishing the guaranteed material properties. 9.2.4 The outer jacket and the equipment not subjected to low temperature shall be manufactured from material suitable for the intended service.

10 Design

10.1 Design options

10.1.1 General

The design shall be carried out in accordance with one of the options given in 10.1.2, 10.1.3 or 10.1.4. Metallic materials used at cryogenic temperatures shall meet the requirements of the relevant clauses of ISO 21028-1 and ISO 21028-2.

In the case of 9 % Ni steel, the additional requirements in Annex C shall be satisfied.

10.1.2 Design by calculation

Calculation of all pressure- and load-bearing components shall be carried out. The pressure part thicknesses of the inner vessel and outer jacket shall not be less than required by 10.3. Additional calculations may be required to ensure the design is satisfactory for the operating conditions including an allowance for dynamic loads.

10.1.3 Design by calculation and pressure strengthening

The pressure-retaining capability of inner vessels manufactured from austenitic stainless steel, strengthened by pressure, shall be calculated in accordance with Annex D.

...