Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications (IEC 61326-2-1:2020)

IEC 61326-2-1:2020 is available as IEC 61326-2-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61326:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (internal or, external to the equipment, or both) that are not EMC protected for operational and/or functional reasons, as specified by the manufacturer. The manufacturer specifies the environment for which the product is intended to be used and selects the appropriate test level specifications of IEC 61326-1:2020.

Elektrische Mess-, Steuer-, Regel- und Laborgeräte – EMV-Anforderungen – Teil 2-1: Besondere Anforderungen – Prüfanordnung, Betriebsbedingungen und Leistungsmerkmale für empfindliche Prüf- und Messgeräte für Anwendungen ohne EMV-Schutzmaßnahme (IEC 61326-2-1:2020)

Matériel électrique de mesure, de commande et de laboratoire - Exigences relatives à la CEM - Partie 2-1: Exigences particulières - Configurations d'essai, conditions fonctionnelles et critères de performance pour essai de sensibilité et équipement de mesure pour les applications non protégées de la CEM (IEC 61326-2-1:2020)

IEC 61326-2-1:2020 est disponible sous forme de IEC 61326-2-1:2020 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.

L’IEC 61326:2020 donne des spécifications plus détaillées des configurations d’essai, des conditions fonctionnelles et des critères de performance pour les matériels avec des circuits d’essai et de mesure (internes et/ou externes au matériel) qui n’ont pas de protection CEM pour des raisons opérationnelles et/ou fonctionnelles, comme spécifié par le fabricant. Le fabricant spécifie l’environnement auquel le produit est destiné et sélectionne les spécifications pertinentes du niveau d’essai de l’IEC 61326-1:2020.

Električna oprema za merjenje, nadzor in laboratorijsko uporabo - Zahteve za elektromagnetno združljivost (EMC) - 2-1. del: Posebne zahteve - Preskusne konfiguracije, obratovalni pogoji in merila učinkovitosti za delovanje občutljive preskusne in merilne opreme za nezaščiteno uporabo EMC (IEC 61326-2-1:2020)

General Information

Status
Published
Public Enquiry End Date
30-Oct-2019
Publication Date
02-Sep-2021
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
11-Jun-2021
Due Date
16-Aug-2021
Completion Date
03-Sep-2021

Relations

Effective Date
08-Jun-2021

Overview

EN IEC 61326-2-1:2021 (CLC adoption of IEC 61326-2-1:2020) defines EMC requirements for sensitive test and measurement equipment used in EMC unprotected applications. It is a particular-part standard that must be used together with IEC 61326-1:2020 (general requirements). The document specifies detailed test configurations, operational conditions and performance criteria for equipment whose test and measurement circuits (internal and/or external) are intentionally not EMC protected for functional reasons.

Key topics and requirements

  • Scope and applicability: Targets equipment such as oscilloscopes, spectrum analysers, network analysers, logic analysers, digital multimeters and board test systems - i.e., devices with exposed test/measurement ports.
  • EMC test plan: Guidance on preparing an EMC test plan in line with IEC 61326-1, with additional detail for sensitive, unprotected instruments.
  • Configuration of EUT during testing: Rules for how the equipment under test (EUT) is arranged, including the handling of I/O ports - e.g., covering and terminating test input ports with appropriate impedances unless that prevents realistic measurement.
  • Operational conditions: Defines required operating modes and signal conditions during immunity and emission testing so performance is assessed in representative use states.
  • Performance criteria: Specifies functional performance levels and acceptance criteria to determine pass/fail under immunity or emission stress.
  • Immunity and emissions: Adds particular immunity test requirements and emission considerations specific to sensitive, unshielded test instruments.
  • Annexes:
    • Annex A (normative): Immunity test requirements for portable test and measurement equipment powered by battery or the circuit under test.
    • Annex B (informative): Guidance for analysis and assessment of electromagnetic compatibility.

Practical applications and users

Who uses EN IEC 61326-2-1:2021:

  • Manufacturers of test and measurement instruments - to define intended environment, select test levels and demonstrate EMC behavior for unprotected ports.
  • Compliance and EMC engineers - to develop test plans, set up test configurations and interpret performance criteria.
  • Test laboratories - as a reference for conducting immunity and emission testing on sensitive equipment.
  • R&D and QA teams - for designing instruments with predictable EMC performance when shielding is not feasible.

Practical value:

  • Ensures consistent, repeatable EMC testing of sensitive measurement equipment.
  • Helps manufacturers declare suitable operating environments and compliance evidence.
  • Reduces risk of measurement errors or device malfunction in real-world installations.

Related standards

  • IEC 61326-1:2020 / EN IEC 61326-1:2021 - General EMC requirements (used in conjunction).
  • IEC 60050-161 - Terminology references used for definitions.

Keywords: EN IEC 61326-2-1:2021, EMC requirements, test and measurement equipment, EMC unprotected applications, immunity testing, emissions, test configurations, performance criteria.

Standard

SIST EN IEC 61326-2-1:2021

English language
13 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN IEC 61326-2-1:2021 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications (IEC 61326-2-1:2020)". This standard covers: <!-- NEW! -->IEC 61326-2-1:2020 is available as <a href="https://webstore.iec.ch/publication/67772">IEC 61326-2-1:2020 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 61326:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (internal or, external to the equipment, or both) that are not EMC protected for operational and/or functional reasons, as specified by the manufacturer. The manufacturer specifies the environment for which the product is intended to be used and selects the appropriate test level specifications of IEC 61326-1:2020.

<!-- NEW! -->IEC 61326-2-1:2020 is available as <a href="https://webstore.iec.ch/publication/67772">IEC 61326-2-1:2020 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.</br></br>IEC 61326:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (internal or, external to the equipment, or both) that are not EMC protected for operational and/or functional reasons, as specified by the manufacturer. The manufacturer specifies the environment for which the product is intended to be used and selects the appropriate test level specifications of IEC 61326-1:2020.

SIST EN IEC 61326-2-1:2021 is classified under the following ICS (International Classification for Standards) categories: 19.080 - Electrical and electronic testing; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC 61326-2-1:2021 has the following relationships with other standards: It is inter standard links to SIST EN 61326-2-1:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC 61326-2-1:2021 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/552. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN IEC 61326-2-1:2021 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2021
Nadomešča:
SIST EN 61326-2-1:2013
Električna oprema za merjenje, nadzor in laboratorijsko uporabo - Zahteve za
elektromagnetno združljivost (EMC) - 2-1. del: Posebne zahteve - Preskusne
konfiguracije, obratovalni pogoji in merila učinkovitosti za delovanje občutljive
preskusne in merilne opreme za nezaščiteno uporabo EMC (IEC 61326-2-1:2020)
Electrical equipment for measurement, control and laboratory use - EMC requirements -
Part 2-1: Particular requirements - Test configurations, operational conditions and
performance criteria for sensitive test and measurement equipment for EMC unprotected
applications (IEC 61326-2-1:2020)
Elektrische Mess-, Steuer-, Regel- und Laborgeräte – EMV-Anforderungen – Teil 2-1:
Besondere Anforderungen – Prüfanordnung, Betriebsbedingungen und
Leistungsmerkmale für empfindliche Prüf- und Messgeräte für Anwendungen ohne EMV-
Schutzmaßnahme (IEC 61326-2-1:2020)
Matériel électrique de mesure, de commande et de laboratoire - Exigences relatives à la
CEM - Partie 2-1: Exigences particulières - Configurations d'essai, conditions
fonctionnelles et critères de performance pour essai de sensibilité et équipement de
mesure pour les applications non protégées de la CEM (IEC 61326-2-1:2020)
Ta slovenski standard je istoveten z: EN IEC 61326-2-1:2021
ICS:
19.080 Električno in elektronsko Electrical and electronic
preskušanje testing
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61326-2-1

NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2021
ICS 25.040.40; 17.220.20; 33.100.20 Supersedes EN 61326-2-1:2013 and all of its
amendments and corrigenda (if any)
English Version
Electrical equipment for measurement, control and laboratory
use - EMC requirements - Part 2-1: Particular requirements -
Test configurations, operational conditions and performance
criteria for sensitive test and measurement equipment for EMC
unprotected applications
(IEC 61326-2-1:2020)
Matériel électrique de mesure, de commande et de Elektrische Mess-, Steuer-, Regel- und Laborgeräte - EMV-
laboratoire - Exigences relatives à la CEM - Partie 2-1: Anforderungen - Teil 2-1: Besondere Anforderungen -
Exigences particulières - Configurations d'essai, conditions Prüfanordnung, Betriebsbedingungen und
fonctionnelles et critères de performance pour essai de Leistungsmerkmale für empfindliche Prüf- und Messgeräte
sensibilité et matériel de mesure pour les applications non für Anwendungen ohne EMV-Schutzmaßnahmen
protégées de la CEM (IEC 61326-2-1:2020)
(IEC 61326-2-1:2020)
This European Standard was approved by CENELEC on 2020-11-27. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61326-2-1:2021 E

European foreword
The text of document 65A/976/FDIS, future edition 3 of IEC 61326-2-1, prepared by SC 65A "System
aspects" of IEC/TC 65 "Industrial-process measurement, control and automation" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61326-2-1:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-12-04
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-06-04
document have to be withdrawn
This document supersedes EN 61326-2-1:2013 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
Endorsement notice
The text of the International Standard IEC 61326-2-1:2020 was approved by CENELEC as a
European Standard without any modification.

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
The Annex ZA of EN IEC 61326-1:2021 applies with the following additions:
Publication Year Title EN/HD Year
IEC 61326-1 2020 Electrical equipment for measurement, EN IEC 61326-1 2021
control and laboratory use - EMC
requirements - Part 1: General
requirements
IEC 61326-2-1 ®
Edition 3.0 2020-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Electrical equipment for measurement, control and laboratory use –

EMC requirements –
Part 2-1: Particular requirements – Test configurations, operational conditions

and performance criteria for sensitive test and measurement equipment for

EMC unprotected applications
Matériel électrique de mesure, de commande et de laboratoire –

Exigences relatives à la CEM –

Partie 2-1: Exigences particulières – Configurations d'essai, conditions

fonctionnelles et critères de performance pour essai de sensibilité et matériel

de mesure pour les applications non protégées de la CEM

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 17.220.20; 25.040.40; 33.100.20 ISBN 978-2-8322-8949-5

– 2 – IEC 61326-2-1:2020 © IEC 2020
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 General . 5
5 EMC test plan . 6
5.1 General . 6
5.2 Configuration of EUT during testing . 6
5.3 Operation conditions of EUT during testing . 6
5.4 Specification of FUNCTIONAL PERFORMANCE . 7
5.5 Test description . 7
6 Immunity requirements . 7
6.1 Conditions during the tests. 7
6.2 Immunity test requirements . 7
6.3 Random aspects . 7
6.4 Performance criteria . 7
7 Emission requirements . 7
8 Test results and test report . 7
9 Instructions for use . 8
Annex A (normative) Immunity test requirements for PORTABLE TEST AND MEASUREMENT
EQUIPMENT powered by battery or from the circuit being measured . 9
Annex B (informative) Guide for analysis and assessment for electromagnetic
compatibility. 10

IEC 61326-2-1:2020 © IEC 2020 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTRICAL EQUIPMENT FOR MEASUREMENT,
CONTROL AND LABORATORY USE –
EMC REQUIREMENTS –
Part 2-1: Particular requirements –
Test configurations, operational conditions and performance
criteria for sensitive test and measurement equipment
for EMC unprotected applications

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entruste
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

記事タイトル:SIST EN IEC 61326-2-1:2021 - 測定、制御、および研究室用電気機器 - EMC要件 - 第2-1部:特定要件 - EMC保護されていないアプリケーション向けの感度の高い試験および測定機器の試験構成、運用条件、および性能基準(IEC 61326-2-1:2020) 記事内容:IEC 61326-1の範囲に加えて、IEC 61326のこの部分では、メーカーによって指定された運用および/または機能的な理由により、EMC保護されていない試験および測定回路(機器内部または機器外部、または両方)に対して、より詳細な試験構成、運用条件、および性能基準を指定しています。メーカーは製品の使用環境を指定し、適切な試験レベル仕様をIEC 61326-1:2020から選択します。 注:この規格に含まれる機器の例には、オシロスコープ、ロジックアナライザ、スペクトラムアナライザ、ネットワークアナライザ、アナログ計測器、デジタルマルチメータ(DMM)、ボードテストシステムなどがあります。

제목: SIST EN IEC 61326-2-1:2021 - 측정, 제어 및 실험실용 전기장비 - EMC 요구사항 - 파트 2-1: 특정 요구사항 - EMC 보호되지 않은 애플리케이션용 민감한 시험 및 측정장비를 위한 시험 구성, 운영 조건 및 성능 기준 (IEC 61326-2-1:2020) 기사 내용: IEC 61326-1의 범위에 추가하여, 이 IEC 61326의 파트는 제조업체가 지정하는 운영 및/또는 기능적인 이유로 EMC 보호되지 않은 장비의 시험 및 측정 회로 (장비 내부 또는 외부, 또는 둘 다)에 대한 더 자세한 시험 구성, 운영 조건 및 성능 기준을 명시합니다. 제조업체는 제품이 사용될 환경을 지정하고 IEC 61326-1:2020의 적절한 시험 수준 사양을 선택합니다. 참고: 장비의 예로는 오실로스코프, 논리 분석기, 스펙트럼 분석기, 네트워크 분석기, 아날로그 장비, 디지털 멀티미터(DMM) 및 보드 테스트 시스템이 포함됩니다.

The article discusses the standard SIST EN IEC 61326-2-1:2021, which pertains to electrical equipment used for measurement, control, and laboratory purposes. This standard provides detailed requirements for test configurations, operational conditions, and performance criteria specifically for sensitive test and measurement equipment that is not electromagnet compatibility (EMC) protected. The manufacturer of such equipment determines the intended usage environment and selects the appropriate test level specifications. Examples of equipment covered by this standard include oscilloscopes, logic analyzers, spectrum analyzers, network analyzers, and digital multimeters.