Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods

This European Standard specifies requirements for the manufacture, performance and testing of emergency exit devices mechanically operated by either a lever handle or a push pad for the purpose of achieving a safe exit under an emergency situation on escape routes.
The suitability of an emergency exit device for use on smoke/fire-resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products.
This European Standard covers emergency exit devices, which are either manufactured and placed on the market in their entirety by one producer, or produced by more than one producer and subsequently placed on the market as a kit in a single transaction.

Schlösser und Baubeschläge - Notausgangsverschlüsse mit Drücker oder Stoßplatte, für Türen in Fluchtwegen - Anforderungen und Prüfverfahren

Diese Europäische Norm legt Anforderungen an Herstellung, Gebrauchstauglichkeit und Prüfung von Notausgangsverschlüssen fest, die mechanisch entweder über einen Drücker oder eine Stoßplatte betätigt werden, um in Notsituationen ein sicheres Entkommen über Fluchtwege zu ermöglichen.
Die Eignung eines Notausgangsverschlusses für den Einsatz an Rauchschutz /Feuerschutztüren wird durch Feuerwiderstandsprüfungen nachgewiesen, die zusätzlich zu den in dieser Europäischen Norm geforderten Prüfungen der Gebrauchstauglichkeit durchgeführt werden. Anhang B enthält zusätzliche Anforderungen an diese Produkte.
Diese Europäische Norm behandelt Notausgangsverschlüsse, die entweder insgesamt durch einen Hersteller gefertigt und auf den Markt gebracht oder durch mehr als einen Hersteller gefertigt und anschließend in einem Vorgang als Montagesatz auf den Markt gebracht werden.

Quincaillerie pour le bâtiment - Fermetures d'urgences manoeuvrées par une béquille ou une plaque de poussée, pour issues de secours situées sur les voies d'évacuation - Prescriptions et méthodes d'essai

La présente Norme européenne spécifie les exigences pour la fabrication, les performances et les essais des
fermetures d’urgence manoeuvrées mécaniquement soit par une béquille, soit par une plaque de poussée, dans le
but d’obtenir une évacuation en toute sécurité dans une situation d’urgence sur des voies d’évacuation.
L’aptitude d'une fermeture d’urgence à équiper des blocs-portes résistant au feu et/ou étanches aux fumées est
déterminée par des essais de performance au feu réalisés en plus des essais de performance exigés par la
présente Norme européenne. L’Annexe B indique les exigences supplémentaires pour ces produits.
La présente Norme européenne couvre les fermetures d’urgence qui sont soit fabriquées ou mises sur le marché
dans leur intégralité par un producteur ou produites par plus d'un producteur et ultérieurement mises sur le marché
en tant que kit au cours d'une transaction unique.

Stavbno okovje - Naprave za zasilne izhode z vzvodno ročico ali pritisnim pedalom za evakuacijske poti - Zahteve in preskusne metode

General Information

Status
Published
Publication Date
06-Apr-2008
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Feb-2008
Due Date
20-Apr-2008
Completion Date
07-Apr-2008

Relations

Buy Standard

Standard
EN 179:2008
English language
61 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methodsQuincaillerie pour le bâtiment - Fermetures d'urgences manoeuvrées par une béquille ou une plaque de poussée, pour issues de secours situées sur les voies d'évacuation - Prescriptions et méthodes d'essaiSchlösser und Baubeschläge - Notausgangsverschlüsse mit Drücker oder Stoßplatte, für Türen in Fluchtwegen - Anforderungen und PrüfverfahrenTa slovenski standard je istoveten z:EN 179:2008SIST EN 179:2008en,fr,de91.190ICS:SIST EN 179:2000/A1:2002/AC:2002SIST EN 179:2000/A1:2002SIST EN 179:20001DGRPHãþDSLOVENSKI
STANDARDSIST EN 179:200801-maj-2008







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 179January 2008ICS 91.190Supersedes EN 179:1997
English VersionBuilding hardware - Emergency exit devices operated by a leverhandle or push pad, for use on escape routes - Requirementsand test methodsQuincaillerie pour le bâtiment - Fermetures d'urgence pourissues de secours manœuvrées par une béquille ou uneplaque de poussée, destinées à être utilisées sur des voiesd'évacuation - Exigences et méthodes d'essaiSchlösser und Baubeschläge - Notausgangsverschlüssemit Drücker oder Stoßplatte für Türen in Rettungswegen -Anforderungen und PrüfverfahrenThis European Standard was approved by CEN on 30 November 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 179:2008: E



EN 179:2008 (E) 2 Contents Page Foreword.4 Introduction.5 1 Scope.7 2 Normative references.7 3 Terms and definitions.7 4 Requirements.11 4.1 Design requirements.11 4.2 Performance requirements.19 4.3 Requirements for product information.24 5 Tests – General and test apparatus.25 5.1 General.25 5.2 Test apparatus.26 6 Test methods – Procedures.28 6.1 General.28 6.2 Test procedure – Test sample A – Environmental tests.28 6.3 Test procedure – Test sample B – Design and performance tests.30 7 Classification.36 7.1 Category of use (1st character).36 7.2 Durability (2nd character).36 7.3 Door mass (3rd character).36 7.4 Suitability for use on fire/smoke doors (4th character).37 7.5 Safety (5th character).37 7.6 Corrosion resistance (6th character).37 7.7 Security (7th character).37 7.8 Projection of operating element (8th character).37 7.9 Type of operation (9th character).38 7.10 Field of door application (10th character).38 7.11 Example of classification.38 8 Marking.39 8.1 On the product.39 8.2 On the packaging.39 8.3 On the installation instructions.39 8.4 Mortise lock combined with a separate operating element.40 9 Evaluation of conformity.40



EN 179:2008 (E) 3 9.1 Initial type test.40 9.2 Sampling, testing and conformity criteria.41 9.3 Factory production control.42 9.4 Periodic testing (for all products).46 9.5 Annual testing (for all products).47 Annex A (normative)
Installation and fixing instructions.48 Annex B (normative)
Additional requirements for emergency exit devices intended for use on smoke/fire resisting door assemblies.51 Annex C (normative)
Maintenance instructions.53 Annex D (normative)
Flow chart of test procedure.54 Annex E (informative)
Guidance for choosing relevant product standards for particular exit door applications.55 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 89/106/EEC, EU Construction Products Directive.56 Bibliography.61



EN 179:2008 (E) 4 Foreword This document (EN 179:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2008, and conflicting national standards shall be withdrawn at the latest by July 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 179:1997. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive 89/106/EEC, see informative Annex ZA which is an integral part of this document. It has been revised to incorporate clarification of the definitions, safety requirements and test procedures, in particular for emergency exit devices intended for use on double leaf doorsets, in order to allow for more reproducible test methods. It incorporates extension of the classification to avoid misuse of the products, extension of the limits of door mass and dimensions as well as extension of the field of application to cover products already available on the market, which were not covered by the 1997 edition of this European Standard. It incorporates additional requirements for emergency exit devices intended for use on inwardly opening single leaf exit doors, which are required by the market. However, no other modifications have been made to the original concept and main requirements. A full contribution to the preparation of this European Standard has been made by The European Federation of Associations of Lock and Builders Hardware Manufacturers (ARGE). This European Standard is part of a group of standards dedicated to building hardware products. It is one of a group of standards for exit devices and exit systems developed by Technical Committee CEN/TC 33. Wherever reference is made to classes, they are considered to be technical classes and not classes according to Article 3(2) of the Construction Products Directive (89/106/EEC). Verification or tests performed by mechanical test laboratory and fire test laboratory are listed in Table 1 summarizing performance characteristics and compliance criteria. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.



EN 179:2008 (E) 5 Introduction Experience relating to escape from buildings, fire and/or smoke hazards and general safety has made it desirable that doors in circulation areas, or those that have to be operated in an emergency situation, be fitted with emergency exit devices to common European Standard specifications. The main purpose of the performance requirements contained in this European Standard is to give safe and effective escape through a doorway with one single operation to release the emergency exit device, although this might require prior knowledge of the door situation (e.g. inwardly opening).
The performance tests incorporated in this European Standard are considered to be reproducible and, as such, will provide a consistent and objective assessment of the performance of these emergency exit devices. Where panic situations are foreseen, reference should be made to EN 1125, covering panic exit devices operated by a horizontal bar. See definition 3.18. Where additional security is required for exit doors, reference should be made to prEN 13633 covering electrically controlled panic exit systems, or to prEN 13637 covering electrically controlled exit systems for use on escape routes. See Bibliography. Due to the wide range of emergency exit devices, the reader is advised to refer to the scope and the detailed contents of this European Standard for coverage but, for information and general guide, this revised European Standard now deals with: • emergency exit devices designed to be used in emergency situations, where people are familiar with the exit and its hardware and therefore a panic situation is most unlikely to develop; • emergency exit devices for use on hinged or pivoted door leaves only; • range of emergency exit devices including those for use on double doorsets (see 7.10); • two specific types of operation: emergency exit devices with “lever handle” operation, type A (see 3.9, see Figures 1 and 3) and emergency exit devices with “push pad” operation, type B (see 3.15, see Figures 2 and 4); • two categories of emergency exit device projection in order to maximize the width of the escape route, and minimize the projection from the door face where either or both of these criteria are of importance (see 4.1.12); • exceptional case of emergency exit devices intended for use on single leaf inwardly opening exit doors. It is assumed throughout this European Standard that emergency exit doors generally open towards the outside in order to assure safe escape. However, there are cases such as hospital or hotel bedroom doors, classroom doors, etc. where local building regulations allow, by way of exception, the exit door to open against the direction of exit; • double doorset emergency exit devices of which the first opening leaf is equipped with a panic exit device conforming to EN 1125 and the second opening leaf is equipped with an emergency exit device conforming to EN 179. It is essential that this combination undergoes an additional test for approval (see 4.2.4). This European Standard does not cover the following:



EN 179:2008 (E) 6 • any particular design of emergency exit devices and only such dimensions as are required for safety reasons are specified; • specific emergency exit devices intended for use on inwardly opening double doorsets; • specific emergency exit devices intended for use by the severely disabled (due to the wide range of disabilities, such emergency exit devices and their performances should be agreed between specifier and producer); • panic exit devices operated by a horizontal bar (see EN 1125) or electrically controlled panic exit systems or electrically controlled exit systems (see prEN 13633 and prEN 13637).



EN 179:2008 (E) 7 1 Scope This European Standard specifies requirements for the manufacture, performance and testing of emergency exit devices mechanically operated by either a lever handle or a push pad for the purpose of achieving a safe exit under an emergency situation on escape routes. The suitability of an emergency exit device for use on smoke/fire-resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products. This European Standard covers emergency exit devices, which are either manufactured and placed on the market in their entirety by one producer, or produced by more than one producer and subsequently placed on the market as a kit in a single transaction. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1125, Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods EN 1634-1, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for doors and shutter assemblies and openable windows EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies EN 1670:2007, Building hardware - Corrosion resistance - Requirements and test methods EN ISO 9001:2000, Quality management systems - Requirements (ISO 9001:2000) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 active leaf first opening and last closing leaf of a rebated single swing double doorset 3.2 automatic relatching device part of an emergency exit device to enable the automatic securing of a door in the closed position, after it has been operated NOTE For example, a spring loaded latch bolt or an automatically thrown bolt head. 3.3 bolt head portion of an emergency exit device that engages with the keeper to secure the door in the closed position



EN 179:2008 (E) 8 3.4 dogging mechanism part of an emergency exit device for holding the bolt head(s) in the withdrawn position until manually reset 3.5 doorset assembly consisting of a single leaf exit door being hinged or pivoted vertically in a frame 3.6 inactive leaf last opening and first closing leaf of a rebated single swing double doorset 3.7 inside face of the door on which the lever handle or push pad is situated for operating an emergency exit device in order to exit 3.8 keeper part of an emergency exit device such as a strike, socket or other fitting with which the bolt head(s) engages 3.9 lever handle rotatable operating element as part of an emergency exit device whose axis of rotation is perpendicular to the face of the door and which operates the emergency exit device mechanism in order to release the bolt head(s) 3.10 producer manufacturer, entity or organization that has legal responsibility for placing the product on the market 3.11 outside face of the door opposite to the face on which the lever handle or push pad for operating the emergency exit device is situated 3.12 outside access device optional part of an emergency exit device for opening an exit device from the outside NOTE An outside access device can be supplied with optional re-entry function. 3.13 operating element abbreviation for lever handle or push pad 3.14 double doorset assembly consisting of two hinged or pivoted exit doors within a single frame NOTE 1 The meeting stiles can be either plain or rebated. NOTE 2 A double doorset where only one leaf is equipped with an emergency exit device is considered to be a single emergency exit doorset. NOTE 3 A double doorset where the first opening leaf is equipped with a panic exit device conforming to EN 1125 and the second opening leaf is equipped with an emergency exit device conforming to EN 179 is considered to be a double emergency exit doorset, or a single panic exit door.



EN 179:2008 (E) 9 3.15 push pad operating element of an emergency exit device that operates the emergency exit device mechanism in order to release the bolt head(s) NOTE The term “pull pad” is sometimes used instead of “push pad” for use on inwardly opening exit doors. 3.16 release force force applied to the operating element, which is necessary to withdraw or release all the bolt head(s) from the keeper(s), such that a door can be opened 3.17 vertical rod extension of the bolt head of an emergency exit device that links it to the operating element via the operating mechanism 3.18 panic exit device exit device conforming to EN 1125 intended to give safe and effective escape through a doorway with minimum effort and without prior knowledge of the panic exit device allowing safe escape even in the event of the door being under pressure such as by people being pushed against the door in the direction of escape NOTE 1 A panic exit device contains bolt head(s) that engage(s) with a keeper(s) in the surrounding door frame and/or floor for securing a door when closed. The bolt head(s) can be released by the bar positioned horizontally across the inside face of the door when it is moved anywhere along its effective length in the direction of travel and/or in an arc downwards. NOTE 2 Panic exit devices are intended for use where panic situations can arise. In a panic situation, a group of people will react differently from an individual. When two or more people are rushing to an escape door, probably in darkness and/or smoke, it is possible that the first one to reach the door will not necessarily operate the panic exit device, but can push the surface of the door (door under pressure) while other people will be trying to operate the horizontal bar by hand or body pressure. NOTE 3 When a door opens in the direction of exit, a panic exit device can be used instead of an emergency exit device subject to local regulations. 3.19 emergency exit device exit device conforming to EN 179 intended for emergency purposes where panic situations are not likely to arise, to give safe and effective escape through a doorway with one single operation to release the emergency exit device, although this can require prior knowledge of its operation (see Figure 1 and Figure 2) NOTE 1 An emergency exit device contains bolt head(s) that engage(s) with a keeper(s) in the surrounding door frame and/or floor for securing a door when closed. The bolt head(s) can be released by the lever handle or the push pad positioned on the inside face of the door. NOTE 2 Exit devices conforming to EN 179 are intended for emergency purposes where panic situations are not likely to arise. Where a pressure against the door caused by people in a panic is foreseen, then a panic exit device conforming to EN 1125 should be used. NOTE 3 Emergency exit devices are suitable also for inwardly opening single leaf exit doors, where local building regulations allow.



EN 179:2008 (E) 10
Figure 1 — Example of type A emergency exit device Figure 2 — Example of type B emergency exit device
3.20 double doorset emergency exit device emergency exit device designed for use on the leaves of double doorsets, such that the operation of either operating element will release at least the door leaf to which it is fitted 3.21 deadbolt part of an emergency exit device that can be deadlocked manually by key or automatically and which is released when the exit device is operated NOTE An emergency exit device can be designed to incorporate additional deadbolt(s) thrown by a key or thumbturn, used only at certain periods of time for additional security. 3.22 exit door door on an escape route equipped with an exit device conforming to EN 179 and/or EN 1125 3.23 free end
furthest point away from the axis or the bearing point of the lever handle or push pad 3.24 re-entry function optional function that allows, for safety reasons, an individual to re-enter a room from outside without a key once the inside operating element has been actuated. After having released the device from the inside, any handle (or other means) to operate the exit device from outside remains unlocked until manually reset by key



EN 179:2008 (E) 11 3.25 field of door application door configurations for which the emergency exit devices are designed and claimed by the producer 3.26 limits of door mass and dimensions
dimensional and mass limits of the doors for which the emergency exit devices are designed 3.27 sub-assemblies pre-assembled set of components that form one part of the emergency exit device, for example: pullman catches, operating boxes and lock cases 3.28 visual inspection
assessment made with the naked eye, adjusted for normal vision and use of the appropriate measurement equipment 3.29 functional test
assessment made by operating the test door (opening or closing) and/or operating any element of
the exit device 3.30 measurement
assessment made by using a measuring tool 4 Requirements 4.1 Design requirements 4.1.1 General Compliance with the design requirements shall be as Table 1.
4.1.2 Release function An emergency exit device shall be designed to release a door at all times from the inside in less than 1 s, by one single hand operation only, not requiring the use of a key or other similar object. It shall be designed to release the door without any delay from the time the operating element is operated to the released position of the mechanism. The operation of the operating element shall enable immediate exit from the inside at all times regardless of any auxiliary locking and/or unlocking means being incorporated, such as a deadbolt or outside access device. Compliance shall be verified by visual inspection, functional tests and/or measurements. 4.1.3 Release operation The release direction of an emergency exit device shall not be opposite to the direction of the door opening. Compliance shall be verified by visual inspection and functional tests.



EN 179:2008 (E) 12 4.1.4 Lever handle design Lever handle operated emergency exit devices shall be designed to release the door following a movement of the lever handle in a downward rotational direction. Compliance shall be verified by visual inspection and functional tests 4.1.5 Push pad design Push pad operated emergency exit devices shall be designed to release the door following a movement in the direction of the door opening in an arc downwards or to the side. This requirement shall also apply to emergency exit devices intended for use on inwardly opening single leaf exit doors. NOTE The term “pull pad” is sometimes used instead of “push pad” for use on inwardly opening single leaf exit doors. Compliance shall be verified by visual inspection and functional tests 4.1.6 Double doorset The design of an emergency exit device intended for use on double doorset leaves shall allow both leaves to be opened simultaneously and to swing freely in the direction of exit once the door has been released. NOTE 1 The construction and installation of a specific doorset assembly, including choice of hinges, leaf thickness and leaf width, can have a significant effect on the ability of both leaves to open simultaneously. These issues are beyond the scope of this European Standard. Additional guidance is given in A.5. NOTE 2 For example, on rebated double doors, operating the emergency exit device on the inactive leaf will release both the inactive and the active leaf. Compliance shall be verified by visual inspection and functional tests carried before and also after durability test. 4.1.7 Corrosion resistance The corrosion resistance shall comply with 4.2.9 or be at least grade 3 in accordance with EN 1670:2007, 5.6.
4.1.8 Exposed edges and corners An emergency exit device shall have all edges and exposed corners, that are likely to cause injury to persons using the exit, rounded to a radius of not less than 0,5 mm. Compliance shall be verified by visual inspection and measurements. 4.1.9 Temperature range Materials selected in the design of an emergency exit device shall be suitable for the operation of the emergency exit device between temperatures of −10 °C and +60 °C. This requirement shall be verified by the test specified in 6.2.2. The maximum operating force at −10 °C and at +60 °C shall not exceed 50 % in excess of the operating forces measured at 20 °C. 4.1.10 Suitability of emergency exit devices for use on smoke/fire-resisting doorsets Emergency exit devices that are suitable for use on smoke/fire-resisting doorsets shall conform to the requirements of 4.2.3, 4.2.4, Annex B and be classified according to 7.4.



EN 179:2008 (E) 13 4.1.11 Push pad installation Push pads shall be designed such that the operating element can be installed at 250 mm or less (dimension Z) from the leading edge of the door when the door is in the closed position. See Figure 4. Compliance shall be verified by visual inspection and measurements 4.1.12 Lever handle installation
Lever handles shall be designed to have a minimum length (dimension X) of 120 mm, measured from the axis of rotation to the free end, and the axis of rotation no more than 150 mm (dimension Z) from the leading edge of the door. See Figure 3. Compliance shall be verified by visual inspection
...