Performance of buildings — Detection of heat, air and moisture irregularities in buildings by infrared methods — Part 3: Qualifications of equipment operators, data analysts and report writers

ISO 6781-3:2015 specifies the qualifications and competence requirements for personnel who (i) perform thermographic investigations on buildings, (ii) interpret the data emanating from thermographic investigations, and (iii) report the results of thermographic investigations. ISO 6781-3:2015 provides the basis for a statement of conformity, in three classes, of the knowledge, skills and abilities of individuals to perform thermographic measurements, analysis and reporting of results for small buildings, residential buildings, and commercial and institutional buildings. ISO 6781-3:2015 is not applicable to specialized equipment or other specific situations.

Performance des bâtiments — Détection d'irrégularités de chaleur, air et humidité dans les bâtiments par des méthodes infrarouges — Partie 3: Qualification des opérateurs de l'équipement, des analystes de données et des rédacteurs de rapports

ISO 6781-3:2015 spécifie les qualifications et compétences requises pour le personnel qui (i) réalise des études thermographiques de bâtiments, (ii) interprète les données issues des études thermographiques et (iii) établit des rapports sur la base des résultats des études thermographiques. ISO 6781-3:2015 sert de base à une déclaration de conformité, en trois classes, des connaissances, des savoir-faire et des aptitudes des individus chargés de réaliser des mesurages thermographiques, une analyse des résultats et les rapports correspondants pour les petits bâtiments, les bâtiments résidentiels, commerciaux et institutionnels. Un équipement spécial ou d'autres situations spécifiques ne sont pas couverts par la présente partie de l'ISO 6781.

General Information

Status
Published
Publication Date
09-Nov-2015
Current Stage
9020 - International Standard under periodical review
Start Date
15-Jan-2026
Completion Date
15-Jan-2026

Relations

Effective Date
12-Feb-2026
Effective Date
06-Jun-2022
Effective Date
06-Jun-2022

Overview

ISO 6781-3:2015 - Performance of buildings: Detection of heat, air and moisture irregularities in buildings by infrared methods - Part 3 - defines the qualifications and competence required for personnel involved in building thermography. The standard sets out competency classes, training and experience requirements, and assessment principles for equipment operators, data analysts, and report writers who perform or interpret infrared thermographic investigations of buildings.

Key topics and requirements

  • Scope and applicability
    • Covers qualifications for personnel who perform thermographic investigations, interpret thermograms, and report results for small, residential, commercial and institutional buildings.
    • Not applicable to specialized equipment or other specific situations.
  • Personnel classification
    • Three competence levels: Class I, Class II, Class III. Each higher class includes the knowledge and skills of lower classes.
    • Class I: safe operation, basic data collection, basic fault detection and reporting.
    • Class II: advanced measurement and interpretation, specification of hardware/software, advanced post-processing, reporting and corrective action recommendations, supervision of Class I.
    • Class III: program and procedure development, severity/acceptance criteria, selection of methods/equipment, prognostics, and leadership.
  • Training, experience and assessment
    • Specifies education, training and minimum practical experience (summarized in the standard’s tables and normative annexes).
    • Includes test instruments (examinations) to verify knowledge, skills and abilities.
    • Competence assessment should conform to ISO/IEC 17024 requirements and be performed by qualified bodies.
  • Normative annexes
    • Annex A and Annex B provide normative training course requirements and details for thermography personnel.

Practical applications - who uses it

  • Building thermographers, energy auditors, building envelope inspectors, HVAC professionals, moisture investigators, facility managers, architects and engineers.
  • Organizations use ISO 6781-3:2015 to:
    • Specify minimum qualifications for contracting thermographic services.
    • Design training and certification programs for thermographers and analysts.
    • Ensure consistent quality of thermographic inspections used in energy audits, moisture intrusion detection, insulation defect identification, and air leakage diagnostics.
    • Provide a conformity basis for competency statements in procurement, certification and regulatory contexts.

Related standards and context

  • Part of the ISO 6781 series on building thermography (other parts cover procedures and equipment requirements).
  • Normative references include ISO 9288:1989 (radiative heat transfer terms) and ISO/IEC 17024:2012 (requirements for bodies certifying persons).

ISO 6781-3:2015 is a practical reference for organizations and professionals who need to ensure reliable, repeatable and interpretable infrared thermographic services for building performance assessment.

Standard

ISO 6781-3:2015 - Performance of buildings -- Detection of heat, air and moisture irregularities in buildings by infrared methods

English language
18 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 6781-3:2015 - Performance des bâtiments -- Détection d'irrégularités de chaleur, air et humidité dans les bâtiments par des méthodes infrarouges

French language
19 pages
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Building products evaluation and certification.

ANAB United States Verified

QAI Laboratories

Building and construction product testing and certification.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

ISO 6781-3:2015 is a standard published by the International Organization for Standardization (ISO). Its full title is "Performance of buildings — Detection of heat, air and moisture irregularities in buildings by infrared methods — Part 3: Qualifications of equipment operators, data analysts and report writers". This standard covers: ISO 6781-3:2015 specifies the qualifications and competence requirements for personnel who (i) perform thermographic investigations on buildings, (ii) interpret the data emanating from thermographic investigations, and (iii) report the results of thermographic investigations. ISO 6781-3:2015 provides the basis for a statement of conformity, in three classes, of the knowledge, skills and abilities of individuals to perform thermographic measurements, analysis and reporting of results for small buildings, residential buildings, and commercial and institutional buildings. ISO 6781-3:2015 is not applicable to specialized equipment or other specific situations.

ISO 6781-3:2015 specifies the qualifications and competence requirements for personnel who (i) perform thermographic investigations on buildings, (ii) interpret the data emanating from thermographic investigations, and (iii) report the results of thermographic investigations. ISO 6781-3:2015 provides the basis for a statement of conformity, in three classes, of the knowledge, skills and abilities of individuals to perform thermographic measurements, analysis and reporting of results for small buildings, residential buildings, and commercial and institutional buildings. ISO 6781-3:2015 is not applicable to specialized equipment or other specific situations.

ISO 6781-3:2015 is classified under the following ICS (International Classification for Standards) categories: 91.120.10 - Thermal insulation of buildings. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 6781-3:2015 has the following relationships with other standards: It is inter standard links to EN ISO 6781-3:2015, ISO/IEC 15476-6:2006, ISO 16410-1:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 6781-3:2015 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 6781-3
First edition
2015-12-01
Performance of buildings — Detection
of heat, air and moisture irregularities
in buildings by infrared methods —
Part 3:
Qualifications of equipment operators,
data analysts and report writers
Performance des bâtiments — Détection d’irrégularités de chaleur,
air et humidité dans les bâtiments par des méthodes infrarouges —
Partie 3: Qualification des opérateurs de l’équipement, des analystes
de données et des rédacteurs de rapports
Reference number
©
ISO 2015
© ISO 2015, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Classification of personnel . 2
4.1 General . 2
4.2 Class I . 2
4.3 Class II. 2
4.4 Class III . 3
5 Eligibility. 3
5.1 General . 3
5.2 Qualifications — Education, training and experience . 4
5.2.1 Education requirements — General . 4
5.2.2 Qualification requirements — Training . 4
5.2.3 Qualifications — Practical experience . 5
6 Test instruments (examinations) . 6
6.1 Administration of test instruments . 6
6.2 Content . 6
6.2.1 Knowledge . 6
6.2.2 Skills . 6
6.2.3 Abilities . 7
Annex A (normative) Training course requirements for thermography personnel.8
Annex B (normative) Training course details .14
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 163 Thermal performance and energy use in the
built environment, Subcommittee SC 1, Test and measurement methods.
ISO 6781 consists of the following parts under the general title Performance of buildings — Detection of
heat, air and moisture irregularities in buildings by infrared methods
— Part 3: Qualifications of equipment operators, data analysts and report writers
The following parts are under development:
— Part 1: General procedures
— Part 2: Equipment requirements
— Part 4: Conducting thermographic inspections and reporting of results for residential and small buildings
— Part 5: Conducting thermographic inspections and reporting of results for commercial buildings
— Part 6: Conducting thermographic inspections and reporting of results for institutional and special
use buildings
A.1, A.2 and Annex B form normative parts of this part of ISO 6781.
iv © ISO 2015 – All rights reserved

Introduction
Reducing energy use in buildings is paramount to improving our environment. Infrared building
thermography provides a tool to quantitatively and qualitatively identify the presence of energy-
wasting defects and anomalies within building structures. These defects and anomalies can include,
for example, thermal insulation defects, moisture content, and / or unwanted air movement or leakage
within the building envelope.
Building thermography is carried out by means of an infrared radiation sensing system, which produces
an image based on the apparent radiance temperature of the target surface area. The thermal radiation
(infrared radiation density) from the target area is converted by the infrared radiation sensing system
to produce a thermal image (thermogram). This image (thermogram) represents the relative intensity
of thermal radiation from different parts of the surface. The radiation intensity indicated by the image
is directly related to (i) the surface temperature and distribution, (ii) the characteristics of the surface,
(iii) the ambient conditions, and (iv) the sensor itself. Also included in the thermographic process is
valid interpretation of the thermal images.
As a result, surface temperature distribution can be a key parameter for monitoring the performance of
building components, building envelopes and the diagnostics of problems. In use, via analysis of surface
temperature distributions, irregularities in the heat and moisture properties of building envelopes and
components, and air movement within the building envelope, can be indicated. These irregularities can
be due to, for example, thermal insulation defects, moisture content, air leakage within components, or
incorrect installation of components which comprise the construction of the building.
To realize its full utility as an initial qualitative screening technique, or in-depth diagnostic technique,
thermography is often supported and / or validated by other methods. Such methods include, but are
not limited to, infrared photosensitive tracer gas methods, fan pressurization of the building envelope,
heat-flow meters, smoke diffusion, anemometry, etc.
The effectiveness of the investigations depends on the competence of individuals who perform
the measurements and analyse the data. A person or entity wishing to use or implement infrared
thermographic services for buildings can refer to this part of ISO 6781 to understand and specify (i) the
competence required of operators of the thermographic equipment, and (ii) the qualifications required
of interpreters of data gathered from the thermographic surveys.
This part of ISO 6781 sets out the requirements and levels of competence that equipment operators,
data analysts and report writers shall possess in order to undertake thermographic investigations and
the analysis and reporting of thermographic results stemming from investigations.
For validity of requirements to this part of ISO 6781, assessment of competence will be undertaken by
bodies qualified to train and assess the competence of personnel whose duties require the appropriate
theoretical and practical knowledge applicable to thermography of buildings.
INTERNATIONAL STANDARD ISO 6781-3:2015(E)
Performance of buildings — Detection of heat, air and
moisture irregularities in buildings by infrared methods —
Part 3:
Qualifications of equipment operators, data analysts and
report writers
1 Scope
This part of ISO 6781 specifies the qualifications and competence requirements for personnel
who (i) perform thermographic investigations on buildings, (ii) interpret the data emanating from
thermographic investigations, and (iii) report the results of thermographic investigations.
This part of ISO 6781 provides the basis for a statement of conformity, in three classes, of the knowledge,
skills and abilities of individuals to perform thermographic measurements, analysis and reporting of
results for small buildings, residential buildings, and commercial and institutional buildings.
This part of ISO 6781 is not applicable to specialized equipment or other specific situations.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 9288:1989, Thermal insulation — Heat transfer by radiation — Physical quantities and definitions
ISO/IEC 17024:2012, Conformity assessment — General requirements for bodies operating certification of
persons
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 9288:1989 and the
following apply.
3.1
trainee
person who is being trained to become qualified
3.2
significant interruption
absence or change of activity which prevents the assessed individual from practising the duties
corresponding to the defined scope of their classification for (a) a continuous period in excess of 365
days or (b) two or more periods for a total time exceeding two-fifths of the total period of validity of the
certificate or declaration of conformity
3.3
test instrument
any means used (whether oral, written or demonstrative) to test that required knowledge, skills and
abilities have been effectively assimilated, and can be effectively deployed in practice, by an individual
3.4
qualification body
body independent of the employer, able to prepare and administer qualification examinations
4 Classification of personnel
4.1 General
Individuals assessed as conforming to the training and practical experience requirements of this
part of ISO 6781 shall be classified into one of three classes depending upon their qualifications. They
shall have demonstrated the necessary knowledge, skills, abilities and experience in thermography
of buildings for their Class as detailed in Annexes A and B. Training durations shall be at least the
minimum duration summarized in Table 1. Required practical experience will be of duration at least
the minimum as summarized in Table 2.
Personnel classified as Class II need to have all the knowledge, skills and abilities expected of personnel
classified as Class I, while personnel classified as Class III need to have all the knowledge, skills and
abilities expected of personnel classified as Class II.
4.2 Class I
For the requirements of this part of ISO 6781 to be met, training specified in 5.2 shall be delivered
by (i) a qualifying body, (ii) training will be delivered by persons fully qualified as Class III for
thermography of buildings, and (iii) assessments of competence shall conform to the requirements
of ISO/IEC 17024:2012 in assessing the knowledge, skills and abilities of personnel who require the
theoretical and practical knowledge applicable to thermography of buildings.
Individuals classified as Class I are qualified to perform infrared thermography of buildings according
to established and recognized procedures. Personnel classified as Class I shall have the knowledge,
skills and abilities to be able to:
a) apply a specified thermographic measurement technique;
b) have knowledge of, set up and operate the thermal imaging equipment for safe thermographic
data collection;
c) prevent, minimize or control poor data and error sources;
d) perform basic fault detection, severity assessment, and diagnosis in accordance with established
instructions;
e) perform basic image post processing (measurement tools, emissivity adjustments, span and scale
adjustments, etc);
f) maintain a database of results and trends;
g) verify the calibration of thermographic measurement systems;
h) in accordance with established criteria, evaluate and report test results and highlight areas of
concern; and
i) be able to recognize and prevent or control factors that result in the acquisition of poor-quality
data (sources of data error).
4.3 Class II
Individuals classified as Class II are qualified to perform infrared thermography of buildings according
to established and recognized procedures. Preparation of reports involving structural components and
2 © ISO 2015 – All rights reserved

elements of buildings shall be undertaken by registered professionals in accordance with local statutes
and regulations. Personnel classified as Class II shall have the knowledge, skills and abilities to be able to:
a) select the appropriate infrared thermography technique and understand its limitations;
b) apply thermography theory and techniques, including measurement and interpretation of
survey results;
c) specify the appropriate hardware and software;
d) perform advanced diagnoses of irregularities found during thermographic investigations;
e) in accordance with industry-accepted practices, standards and regulations and statutes,
recommend appropriate corrective actions;
f) perform advanced image post processing (image, trending, montage, subtraction, super-imposition,
statistical analysis, etc.);
g) use generally recognized advanced techniques for infrared thermography of buildings and
diagnosis of irregularities in accordance with established procedures;
h) prepare reports on as-found building condition, faults, irregularities and diagnoses, and
recommend corrective actions for repair and remediation;
i) be aware of the use of alternative or supplementary technologies that support or enhance the
effectiveness of thermographic investigations of buildings;
j) provide guidance to and supervise Class I personnel.
4.4 Class III
Individuals classified as Class III are qualified to perform infrared thermography of buildings according
to established and recognized procedures. Personnel classified as Class III shall have the knowledge,
skills and abilities to be able to:
a) develop and establish thermographic programmes, procedures, and instructions including
determination of regimens for periodic / continuous monitoring, frequency of testing, the use of
advanced techniques;
b) determine severity assessment and acceptance criteria for new, existing and renovated buildings;
c) interpret and evaluate codes, standards, specifications and procedures;
d) designate the particular test methods, procedures, equipment and instructions to be used;
e) perform prognostics for detected heat, air movement and moisture irregularities;
f) recommend appropriate types of corrective actions based on sound building technology practices;
g) provide guidance to and supervise Class I and II personnel; and
h) be able to recommend the use of alternative or supplementary technologies for detection of heat,
air and moisture irregularities in buildings by infrared methods.
5 Eligibility
5.1 General
Candidates shall have a combination of education, training and experience to ensure that they
understand the principles and procedures applicable to thermographic measurement, analysis and
report writing.
Candidates shall have colour perception assessed by the Ishihara 24 plate test. A record of test results
shall be retained and presented to the assessment body upon request. In the event that a colour
perception deficiency, indicated by misreading four or more of the 24 plates, is detected during the
Ishihara test, a further ‘task specific’ test is to be carried out by the employer to ascertain whether the
detected colour perception deficiency affects the individual’s ability to satisfactorily perform analysis
of thermographic data using colour palettes. Failure to pass this test shall require the candidate to use
a monochrome palette. This ‘task specific’ test, and any requirement to use a monochrome palette, is to
be documented and the record of the test made available to the assessment body upon request.
5.2 Qualifications — Education, training and experience
5.2.1 Education requirements — General
Candidates seeking classification do not need to provide evidence of formal education to establish
eligibility. Candidates for Class I and II shall have at least a secondary school (i.e. high school) or
equivalent graduate qualification. Class II and III shall be able to manipulate simple algebraic equations,
use a scientific calculator, and be familiar with the operation of personal computers.
It is recommended for candidates seeking classification to Class III that two or more years of mechanical
technology, building technology or mechanical engineering at a college, university, or training at a
technical school, be successfully completed.
5.2.2 Qualification requirements — Training
Candidates shall be qualified by confirming the knowledge, skills and abilities outlined in the essential
learning specified in 4.2, 4.3 and 4.4. The prerequisites required to attain each level of classification are
listed in 5.1 and 5.2. The competence requirements for each of an equipment operator, a data analyst,
and a report writer shall be the same.
5.2.2.1 Structure of training materials
Training shall be modularised into two or more subject areas covering general scientific principles of
thermography, application-specific knowledge of building thermography, and building technology, in
order to allow for mutual recognition between building-thermography training and assessment bodies.
5.2.2.2 Candidate training — Building thermography
To be eligible to apply for a Class based on this part of ISO 6781, candidates shall submit evidence of
training in thermography subjects in accordance with the requirements and minimum training time
of Annex A. Training shall be in the form of lectures, demonstrations, practical exercises or formal
training courses.
5.2.2.3 Candidate training — Building technology
Candidates shall attend and successfully complete building technology training, or equivalent on-the-job
training, as assessed by the qualification body (3.4), of at least a similar duration as specified in Annex A.
Building technology training shall be in addition to the general education requirements in 5.2.1.
Class I training shall consist of the design, construction, installation and maintenance of building
materials and systems as it relates to the heat, air and moisture flow in buildings.
Class II training shall consist of the building science principles related to the degradation and failure of
materials and systems as it relates to the heat, air and moisture flow in buildings.
Class III training shall consist of the building science principles related to the mitigation, remediation
and/or replacement of materials and systems as it relates to the heat, air and moisture flow in buildings.
4 © ISO 2015 – All rights reserved

Training shall include the design, manufacturing, installation, operation, and maintenance principles
of building construction and components, the failure modes and mechanisms associated with each
principle, and the typical thermodynamic behaviours associated with each mechanism. Records of
training shall be provided.
5.2.2.4 Total minimum training time
For ab-initio trainees, the total minimum training time to cover all subjects in accordance with Annex A
is summarized in Table 1:
Table 1 — Minimum duration of training in each class (hours)
Class I Class II Class III
60 60 40
5.2.3 Qualifications — Practical experience
Candidates shall submit verified documented evidence of practical experience in thermographic
building investigations and evaluations in accordance with 4.2, 4.3 and 4.4 and of at least the duration
shown on Table 2.
Verifiable documentary evidence of hours and nature of candidate’s thermography-based building
investigations experience shall be provided for Class I. Class I candidates shall have this evidence
validated by a Class II or III person and by a second qualified independent person or body. Class II
candidates shall have this evidence validated by a Class III person and by a second qualified independent
person or body. The validation process for all categories requires the signature of the validating
persons on the documentary evidence. The validating persons shall augment this validation process
via oral assessment based on the requirements of this part of ISO 6781, accompanied task performance,
reports’ submission and review, procedures’ submission and review, or a combination thereof in order
to ensure confidence in the validation.
Attainment of the next Class requires that the previous Class practical work experience has been attained.
Table 2 — Minimum practical, interpretation and programme-management experience
requirements (months and hours)
Class I Class II Class III
12 months 24 months 48 months
a a a
400 h 1200 h 1920 h
a Denotes the actual hours of practical thermography experience that are required.
5.2.3.1 Candidates with practical experience in other fields of thermography
For candidates with verified practical experience in fields of thermography other than buildings, and
complying with this part of ISO 6781, a modular supplementary training course designed to cover the
topics particular to thermographic investigations of building performance shall be undertaken.
The supple
...


NORME ISO
INTERNATIONALE 6781-3
Première édition
2015-12-01
Performance des bâtiments —
Détection d’irrégularités de chaleur,
air et humidité dans les bâtiments par
des méthodes infrarouges —
Partie 3:
Qualification des opérateurs de
l’équipement, des analystes de
données et des rédacteurs de rapports
Performance of buildings — Detection of heat, air and moisture
irregularities in buildings by infrared methods —
Part 3: Qualifications of equipment operators, data analysts and
report writers
Numéro de référence
©
ISO 2015
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2015, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2015 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Classification du personnel . 2
4.1 Généralités . 2
4.2 Classe I. 2
4.3 Classe II . 3
4.4 Classe III . 3
5 Admissibilité . 4
5.1 Généralités . 4
5.2 Qualifications — Formation théorique, formation pratique et expérience . 4
5.2.1 Exigences relatives à la formation théorique — Généralités. 4
5.2.2 Exigences relatives à la qualification — Formation . 4
5.2.3 Qualifications — Expérience pratique . 5
6 Instruments de test (examens) . 6
6.1 Administration des instruments de test . 6
6.2 Contenu . 6
6.2.1 Connaissances . 7
6.2.2 Savoir-faire . 7
6.2.3 Aptitudes . 7
Annexe A (normative) Annexe AExigences relatives aux cours de formation pour le
personnel en charge de la thermographie . 9
Annexe B (normative) Annexe BDétails des cours de formation .15
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer
un engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à l’évaluation
de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes de l’OMC
concernant les obstacles techniques au commerce (OTC), voir le lien suivant : Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 163 Performance thermique et
utilisation de l’énergie en environnement bâti, sous-comité SC 1, Méthodes d’essais et de mesurage.
L’ISO 6781 comprend les parties suivantes, présentées sous le titre général Performance des bâtiments —
Détection d’irrégularités de chaleur, air et humidité dans les bâtiments par des méthodes infrarouges
— Partie 3 : Qualification des opérateurs de l’équipement, des analystes de données et des rédacteurs de
rapports
Les parties suivantes sont en préparation:
— Partie 1 : Modes opératoires généraux
— Partie 2 : Exigences relatives à l’équipement
— Partie 4: Conduite de contrôles thermographiques et consignation des résultats pour les petits bâtiments
et les bâtiments résidentiels
— Partie 5: Conduite de contrôles thermographiques et consignation des résultats pour les petits
bâtiments commerciaux
— Partie 6: Conduite de contrôles thermographiques et consignation des résultats pour les bâtiments
institutionnels et les bâtiments à usage spécial
Les Articles A.1, A.2 et l’Annexe B constituent des parties normatives de la présente partie de l’ISO 6781.
iv © ISO 2015 – Tous droits réservés

Introduction
Il est primordial de réduire l’utilisation de l’énergie dans les bâtiments pour améliorer notre
environnement. La thermographie infrarouge appliquée aux bâtiments fournit un outil permettant
d’identifier quantitativement et qualitativement la présence de défauts et d’anomalies dans les
structures de bâtiments à l’origine d’une déperdition d’énergie. Ces défauts et anomalies peuvent
inclure, par exemple, les défauts d’isolation thermique, la teneur en humidité et/ou une circulation d’air
ou des fuites indésirables dans l’enveloppe du bâtiment.
La thermographie appliquée aux bâtiments est réalisée au moyen d’un système de détection de
rayonnement infrarouge qui produit une image basée sur la température apparente de la surface
cible. Le rayonnement thermique (densité du rayonnement infrarouge) émis par la surface cible est
converti par le système de détection de rayonnement infrarouge pour produire une image thermique
(thermogramme). Cette image (thermogramme) représente l’intensité relative du rayonnement
thermique émis par les différentes parties de la surface. L’intensité du rayonnement indiquée par
l’image est directement liée (i) à la température de surface et sa distribution, (ii) aux caractéristiques
de la surface, (iii) aux conditions ambiantes et (iv) au capteur lui-même. Le procédé thermographique
comprend également une interprétation valable des images thermiques.
De ce fait, la distribution de la température de surface peut être un paramètre clé pour la surveillance
de la performance des éléments du bâtiment, des enveloppes de bâtiment et le diagnostic des problèmes.
Dans la pratique, elle permet d’indiquer, par le biais d’une analyse des distributions de température de
surface, toute irrégularité dans les caractéristiques de chaleur et d’humidité des enveloppes et éléments
du bâtiment, et dans la circulation d’air à l’intérieur de l’enveloppe du bâtiment. Ces irrégularités
peuvent être dues, par exemple, à des défauts d’isolation thermique, à la teneur en humidité, à des fuites
d’air dans les éléments ou à une installation incorrecte des éléments qui constituent le bâtiment.
Pour tirer pleinement profit de la thermographie en tant que technique de contrôle qualitatif initial ou
de technique de diagnostic approfondi, elle est souvent complétée et/ou validée par d’autres méthodes.
Ces méthodes comprennent, sans toutefois s’y limiter, des méthodes utilisant un gaz de dépistage
photosensible à l’infrarouge, une pressurisation par ventilateur de l’enveloppe du bâtiment, des
fluxmètres thermiques, une diffusion de fumée, l’anémométrie, etc.
L’efficacité des études dépend des compétences des individus réalisant les mesurages et analysant
les données. Une personne ou une entité souhaitant utiliser ou mettre en œuvre des services de
thermographie infrarouge pour les bâtiments peut se reporter à la présente partie de l’ISO 6781 pour
comprendre et spécifier (i) les compétences requises des opérateurs de l’équipement thermographique
et (ii) les qualifications requises des personnes chargées de l’interprétation des données rassemblées
lors des relevés thermographiques.
La présente partie de l’ISO 6781 spécifie les exigences et les niveaux de compétence définis que doivent
posséder les opérateurs de l’équipement, les analystes de données et les rédacteurs de rapports pour
réaliser des études thermographiques, analyser les résultats thermographiques obtenus lors de ces
études et établir les rapports correspondants.
Pour valider la conformité aux exigences de la présente partie de l’ISO 6781, l’évaluation des compétences
sera réalisée par des organismes qualifiés pour former et évaluer les compétences du personnel dont
les fonctions nécessitent des connaissances théoriques et pratiques appropriées dans le domaine de la
thermographie appliquée aux bâtiments.
NORME INTERNATIONALE ISO 6781-3:2015(F)
Performance des bâtiments — Détection d’irrégularités
de chaleur, air et humidité dans les bâtiments par des
méthodes infrarouges —
Partie 3:
Qualification des opérateurs de l’équipement, des
analystes de données et des rédacteurs de rapports
1 Domaine d’application
La présente partie de l’ISO 6781 spécifie les qualifications et compétences requises pour le personnel
qui (i) réalise des études thermographiques de bâtiments, (ii) interprète les données issues des études
thermographiques et (iii) établit des rapports sur la base des résultats des études thermographiques.
La présente partie de l’ISO 6781 sert de base à une déclaration de conformité, en trois classes, des
connaissances, des savoir-faire et des aptitudes des individus chargés de réaliser des mesurages
thermographiques, une analyse des résultats et les rapports correspondants pour les petits bâtiments,
les bâtiments résidentiels, commerciaux et institutionnels.
Un équipement spécial ou d’autres situations spécifiques ne sont pas couverts par la présente partie
de l’ISO 6781.
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 9288:1989, Isolation thermique — Transfert de chaleur par rayonnement — Grandeurs physiques
et définitions
ISO/IEC 17024:2012, Évaluation de la conformité — Exigences générales pour les organismes de
certification procédant à la certification de personnes
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 9288:1989 ainsi que
les termes et définitions suivants s’appliquent.
3.1
stagiaire
personne qui est formée en vue d’une qualification
3.2
interruption significative
absence ou changement d’activité qui empêche l’individu évalué de pratiquer les tâches correspondant
au périmètre défini de sa classification pendant (a) une période continue de plus de 365 jours ou
(b) deux périodes ou plus dont la durée totale dépasse les deux cinquièmes de la durée totale de validité
du certificat ou de la déclaration de conformité
3.3
instrument de test
tout moyen utilisé (oral, écrit ou pratique) pour évaluer si les connaissances, le savoir-faire et les
aptitudes requises ont été effectivement assimilées et peuvent être déployées efficacement dans la
pratique par un individu
3.4
organisme de qualification
organisme, indépendant de l’employeur, ayant la capacité de préparer et gérer les examens de
qualification
4 Classification du personnel
4.1 Généralités
Les individus évalués comme répondant aux exigences relatives à la formation et à l’expérience pratique
de la présente partie de l’ISO 6781 doivent être classés dans l’une des trois classes en fonction de leurs
qualifications. Ils doivent avoir démontré qu’ils possèdent les connaissances, le savoir-faire et les
aptitudes en thermographie appliquée aux bâtiments nécessaires pour leur classe, telles que présentées
aux Annexes A et B. Les durées de formation doivent correspondre aux durées minimales spécifiées
dans le Tableau 1. La durée de l’expérience pratique requise doit correspondre à la durée minimale telle
que spécifiée dans le Tableau 2.
Le personnel classé en Classe II doit posséder toutes les connaissances, le savoir-faire et les aptitudes
attendues pour le personnel classé en Classe I, alors que le personnel classé en Classe III doit posséder
toutes les connaissances, le savoir-faire et les aptitudes attendues pour le personnel classé en Classe II.
4.2 Classe I
Pour que les exigences de la présente partie de l’ISO 6781 soient satisfaites, la formation spécifiée
au 5.2 doit être dispensée par (i) un organisme de qualification, (ii) des personnes disposant d’une
qualification de Classe III en thermographie appliquée aux bâtiments, et (iii) des évaluations de
compétence, qui doivent être conformes aux exigences de l’ISO/IEC 17024:2012 relatives à l’évaluation
des connaissances, du savoir-faire et des aptitudes du personnel qui doit posséder des connaissances
théoriques et pratiques en matière de thermographie appliquée aux bâtiments.
Les individus classés en Classe I sont qualifiés pour réaliser une thermographie infrarouge des
bâtiments conformément à des modes opératoires établis et reconnus. Le personnel classé en Classe I
doit posséder les connaissances, le savoir-faire et les aptitudes lui permettant :
a) d’appliquer une technique spécifiée de mesurage thermographique ;
b) de connaître, de régler et d’utiliser l’équipement d’imagerie thermique pour recueillir les données
thermographiques en toute sécurité ;
c) de prévenir, de réduire au minimum ou de contrôler les données de mauvaise qualité et les
sources d’erreur ;
d) d’effectuer une détection des défauts de base, une évaluation de la gravité et un diagnostic
conformément à des instructions établies ;
e) d’effectuer le post-traitement d’image de base (outils de mesure, réglages de l’émissivité, réglages
de l’intervalle de mesure et de l’échelle, etc.) ;
f) de tenir à jour une base de données des résultats et des tendances ;
g) de vérifier l’étalonnage des systèmes de mesure thermographique ;
h) d’évaluer les résultats d’essai, conformément à des critères établis, d’établir les rapports
correspondants et de mettre en évidence les sujets de préoccupation ; et
2 © ISO 2015 – Tous droits réservés

i) d’être en mesure de reconnaître et de prévenir ou de maîtriser les facteurs à l’origine de l’acquisition
de données de mauvaise qualité (sources d’erreur de données).
4.3 Classe II
Les individus classés en Classe II sont qualifiés pour réaliser une thermographie infrarouge des
bâtiments conformément à des modes opératoires établis et reconnus. Les rapports concernant les
composants et éléments de structure des bâtiments doivent être élaborés par des professionnels agréés
conformément à la législation et aux réglementations locales. Le personnel classé en Classe II doit
posséder les connaissances, le savoir-faire et les aptitudes lui permettant :
a) de choisir la technique de thermographique infrarouge appropriée et d’en comprendre les limites ;
b) d’appliquer la théorie et les techniques de thermographie, y compris le mesurage et l’interprétation
des résultats des relevés ;
c) de spécifier le matériel et le logiciel appropriés ;
d) de réaliser un diagnostic approfondi des irrégularités observées pendant les études
thermographiques ;
e) de recommander des actions correctives appropriées, conformément à des pratiques acceptées
dans l’industrie, des normes, des réglementations et des textes législatifs ;
f) d’effectuer un post-traitement d’image avancé (analyse de tendance, montage, soustraction,
superposition, analyse statistique de l’image, etc.) ;
g) d’utiliser des techniques de pointe généralement reconnues pour la thermographie infrarouge
appliquée aux bâtiments et le diagnostic des irrégularités conformément à des modes
opératoires établis ;
h) d’élaborer des rapports sur l’état observé du bâtiment, les défauts, les irrégularités et les
diagnostics, et de recommander des actions correctives pour la réparation et la restauration ;
i) d’être sensibilisé à l’utilisation de technologies de remplacement ou complémentaires pour appuyer
ou renforcer l’efficacité des études thermographiques de bâtiments ;
j) de donner des directives au personnel de Classe I et de le superviser.
4.4 Classe III
Les individus classés en Classe III sont qualifiés pour réaliser une thermographie infrarouge des
bâtiments conformément à des modes opératoires établis et reconnus. Le personnel classé en Classe III
doit posséder les connaissances, le savoir-faire et les aptitudes lui permettant :
a) de développer et d’établir des programmes thermographiques, des modes opératoires et des
instructions, y compris la détermination des régimes de surveillance périodique/continue, la
fréquence d’essai, l’utilisation de techniques avancées ;
b) de déterminer les critères d’évaluation de la gravité et d’acceptation pour les bâtiments neufs,
existants et rénovés ;
c) d’interpréter et d’évaluer les codes, les normes, les spécifications et les modes opératoires ;
d) de désigner les méthodes d’essai, les modes opératoires, l’équipement et les instructions
particulières à appliquer ;
e) d’établir un pronostic pour les irrégularités de chaleur, de circulation d’air et d’humidité détectées ;
f) de recommander les types appropriés d’actions correctives sur la base de pratiques saines en
matière de techniques du bâtiment ;
g) de donner des directives au personnel de Classes I et II et de le superviser ; et
h) d’être en mesure de recommander l’utilisation de techniques complémentaires ou de remplacement
pour la détection des irrégularités de chaleur, de circulation d’air et d’humidité dans les bâtiments
par des méthodes infrarouges.
5 Admissibilité
5.1 Généralités
Les candidats doivent disposer à la fois d’une formation initiale et continue et d’une expérience
permettant de s’assurer qu’ils comprennent les principes et les modes opératoires applicables au
mesurage thermographique, à l’analyse et à la rédaction de rapports.
La perception des couleurs par les candidats doit être évaluée par le test d’Ishihara édition 24 planches.
Un enregistrement des résultats du test doit être conservé et présenté à l’organisme d’évaluation sur
demande. Lorsqu’une déficience dans la perception des couleurs, indiquée par une mauvaise lecture
d’au moins quatre des 24 planches, est détectée lors du test d’Ishihara, un test supplémentaire
« spécifique à la tâche » doit être effectué par l’employeur afin de déterminer si la déficience dans la
perception des couleurs affecte l’aptitude de l’individu à réaliser de manière satisfaisante une analyse
de données thermographiques en utilisant des palettes de couleurs. En cas d’échec à ce test, le candidat
doit utiliser une palette monochrome. Ce test « spécifique à la tâche » et toute exigence d’utiliser une
palette monochrome doivent être documentés et l’enregistrement du test doit être mis à la disposition
de l’organisme d’évaluation sur demande.
5.2 Qualifications — Formation théorique, formation pratique et expérience
5.2.1 Exigences relatives à la formation théorique — Généralités
Les candidats recherchant une classification n’ont pas à fournir la preuve d’une éducation formelle
pour établir leur admissibilité. Les candidats aux Classes I et II doivent au moins posséder un diplôme
de niveau secondaire (c’est-à-dire d’études secondaires) ou un diplôme équivalent. Les candidats aux
Classes II et III doivent être en mesure de manipuler des équations algébriques simples, d’utiliser une
calculatrice scientifique et d’être familiarisés avec l’utilisation d’ordinateurs personnels.
Il est recommandé pour les candidats recherchant une classification en Classe III qu’au moins deux
années d’études dans le domaine de la technologie mécanique, des techniques de construction ou du
génie mécanique, menées dans un collège, une université ou une formation dans une école technique
soient validées.
5.2.2 Exigences relatives à la qualification — Formation
Les candidats doivent être qualifiés en confirmant qu’ils possèdent les connaissances, le savoir-faire
et les aptitudes indiquées dans l’apprentissage de base spécifié en 4.2, 4.3 et 4.4. Les prérequis pour
atteindre chaque niveau de classification sont énumérées en 5.1 et 5.2. Les exigences en termes de
compétence pour chaque opérateur d’équipement, analyste de données et rédacteur de rapports doivent
être identiques.
5.2.2.1 Structure du matériel de formation
La formation doit être modularisée en deux domaines, ou plus, couvrant les principes scientifiques
généraux appliqués à la thermographie et les connaissances spécifiques à l’application de la
thermographie aux bâtiments et aux techniques du bâtiment, afin de permettre une reconnaissance
mutuelle entre les organismes de formation et d’évaluation en thermographie appliquée aux bâtiments.
4 © ISO 2015 – Tous droits réservés

5.2.2.2 Formation des candidats — Thermographie appliquée aux bâtiments
Pour être admissible à une Classe fondée sur la présente partie de l’ISO 6781, les candidats doivent
fournir la preuve d’une formation dans le domaine de la thermographie en conformité aux exigences et
à la durée minimale de formation selon l’Annexe A. La formation doit prendre la forme de lectures, de
démonstrations, d’exercices pratiques ou de séances de formation théorique.
5.2.2.3 Formation des candidats — Techniques du bâtiment
Les candidats doivent suivre et valider une formation en techniques du bâtiment, ou une formation
équivalente en milieu de travail, telle qu’évaluée par l’organisme de qualification (3.4), d’une durée au
moins égale à celle spécifiée dans l’Annexe A.
La formation en techniques du bâtiment doit venir compléter les exigences générales relatives à la
formation initiale en 5.2.1.
La formation relative à la Classe I doit couvrir la conception, la construction, l’installation et la
maintenance des matériaux et systèmes de construction dans la mesure où ils se rapportent aux flux de
chaleur, d’air et d’humidité dans les bâtiments.
La formation relative à la Classe II doit couvrir les principes de la science du bâtiment liés à la dégradation
et à la défaillance des matériaux et systèmes de construction dans la mesure où ils se rapportent aux
flux de chaleur, d’air et d’humidité dans les bâtiments.
La formation relative à la Classe III doit couvrir les principes de la science du bâtiment liés à l’atténuation
des impacts, à la restauration et/ou au remplacement des matériaux et systèmes de construction dans
la mesure où ils se rapportent aux flux de chaleur, d’air et d’humidité dans les bâtiments.
La formation doit inclure les principes de conception, de fabrication, d’installation, de fonctionnement
et de maintenance de la construction et des éléments des bâtiments, les modes de défaillance et les
mécanismes associés à chaque principe, ainsi que les comportements thermodynamiques types
associés à chaque mécanisme. Les enregistrements relatifs à la formation doivent être fournis.
5.2.2.4 Durée minimale de formation totale
Pour les stagiaires débutants, la durée minimale cumulée de formation pour couvrir tous les aspects du
programme conformément à l’Annexe A est spécifiée dans le Tableau 1 :
Tableau 1 — Durée minimale de formation (heures)
Classe I Classe II Classe III
60 60 40
5.2.3 Qualifications — Expérience pratique
Les candidats doivent fournir une preuve documentée de leur expérience pratique dans le domaine des
études et évaluations thermographiques des bâtiments conformément aux 4.2, 4.3 et 4.4 et d’une durée
minimale telle qu’indiquée dans le Tableau 2.
Une preuve documentaire vérifiable du nombre d’heures et de la nature des travaux des candidats
correspondant à leur expérience dans le domaine des études thermographiques des bâtiments doit être
fournie pour la Classe I. Les candidats de Classe I doivent faire valider cette preuve par une personne de
Classe II ou III, ainsi que par une autre personne ou un autre organisme indépendant(e) qualifié(e). Les
candidats de Classe II doivent faire valider cette preuve par une personne de Classe III et par une autre
personne ou un autre organisme indépendant(e) qualifié(e). Pour toutes les catégories, le processus
de validation nécessite que les personnes assurant la validation signent la preuve documentaire. Les
personnes assurant la validation doivent compléter ce processus de validation par une évaluation
orale, basée sur les exigences relatives à la présente partie de l’ISO 6781, accompagnée de l’exécution
de tâches, d’une soumission et d’une revue de rapports, d’une soumission et d’une revue de modes
opératoires, ou d’une combinaison de celles-ci, afin de consolider la validation.
L’obtention de la classe suivante nécessite l’acquisition d’une expérience professionnelle pratique dans
la classe précédente.
Tableau 2 — Exigences minimales en termes d’expérience pratique, d’interprétation et de
gestion de programme (mois et heures)
Classe I Classe II Classe III
12 mois 24 mois 48 mois
a a a
400 h 1200 h 1920 h
a Indique le nombre d’heures d’expérience réelle en thermographie qui est requis.
5.2.3.1 Candidats ayant une expérience pratique dans d’autres domaines de la thermographie
En ce qui concerne les candidats ayant une expérience pratique avérée dans les domaines de la
thermographie autres que ceux relatifs aux bâtiments, et conforme à la présen
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...