ISO 20421-1
(Main)Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing
- Abstract
This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport. This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids. This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.
- Status
- Not Published
- Technical Committee
- ISO/TC 220 - Cryogenic vessels
- Drafting Committee
- ISO/TC 220/WG 1 - Design and construction
- Current Stage
- 6000 - International Standard under publication - 60 Publication
- Start Date
- 19-Nov-2026
Buy Documents
ISO/FDIS 20421-1 - Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing
REDLINE ISO/FDIS 20421-1 - Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing
ISO/FDIS 20421-1 - Récipients cryogéniques — Grands récipients transportables isolés sous vide — Partie 1: Conception, fabrication, inspection et essais
ISO 20421-1 is an ISO standard for large transportable vacuum-insulated cryogenic vessels. It specifies requirements for the design, fabrication, inspection and testing of vessels over 450 l that are permanently or non-permanently attached to transport equipment, for use in one or more transport modes. The document is intended for manufacturers, designers, inspectors and buyers of cryogenic transport equipment, and it excludes vessels designed for toxic fluids, general vehicle equipment and fuel tanks covered by ISO 13985.
What does ISO 20421-1 specify?
ISO 20421-1 specifies the technical requirements for large transportable vacuum-insulated cryogenic vessels, including fixed tanks, demountable tanks and portable tanks. The standard is organized into clauses 1 to 16, from scope and definitions through design, fabrication, inspection and testing, marking, final acceptance, periodic inspection and documentation.
| Annex | What it covers |
|---|---|
| Annex A | Examples of tank plates and their markings |
| Annex B | Elastic stress analysis |
| Annex C | Additional requirements for 9 % Ni steel |
| Annex D | Pressure strengthening of vessels from austenitic stainless steels |
| Annex E | Specific weld details |
| Annex F | Outer-jacket relief devices |
| Annex G | Base materials |
| Annex H | Components subject to external pressure - calculation |
| Annex I | Design of openings in cylinders, spheres and cones - calculation |
| Annex J | Reference material and equivalent thickness |
| Annex K | Refrigerated liquefied gases |
What are the key requirements of ISO 20421-1?
ISO 20421-1 is built around safe pressure containment, transport loads, cryogenic compatibility and verifiable manufacturing control. The most important requirements are in Clauses 5 to 16 and in the calculation annexes.
Safety basis and service conditions
- Clause 5.1 requires the vessel to withstand the mechanical loads, thermal loads and chemical effects encountered in pressure testing and normal operation. In practice, the design has to cover the whole service condition, not just the pressure boundary.
- Clause 5.2 requires the vessel to be configured for safe operation, with valves and pressure-relief devices, and the number of openings in the inner vessel kept to a minimum. Fewer openings reduce leakage points and simplify inspection.
- Clause 5.3 requires cleanliness for the intended service in accordance with ISO 23208. This matters because contamination can create safety risks in cryogenic service.
- Clause 5.4 requires the manufacturer to retain the conformity documents and all supporting records, including subcontractor records. That supports traceability, audits and product liability review.
Loads, materials and design
- Clause 6.1 requires the vessel to resist the mechanical loads defined in the design section without deformation that could affect safety or cause leakage. The standard allows three validation routes: calculation, calculation plus pressure strengthening where permitted, or calculation plus experiment.
- Clause 6.2 defines the pressure-test load relationship, so the proof test pressure is not chosen arbitrarily. This gives the basis for setting the test condition used to verify strength.
- Clause 7 states that chemical action on internal surfaces in contact with cryogenic fluids can be neglected, and corrosion allowance is not required on surfaces in contact with the operating fluid or the vacuum interspace. Surfaces exposed to the atmosphere still need materials and protection suitable for the intended environment.
- Clause 8 requires the inner vessel and its associated equipment to cover the full expected temperature range, while the outer jacket and its equipment are designed for a minimum working temperature of -20 °C and a maximum of 50 °C, unless a lower temperature is marked. This is what drives material choice and low-temperature qualification.
- Clause 9 links material selection to cryogenic service and low-temperature toughness, with inspection documentation required for the material supply. The outer jacket and equipment not exposed to low temperature are treated separately from the cryogenic parts.
Design checks and calculation methods
- Clause 10.2 sets the common design requirements for loads, fatigue, corrosion allowance, inspection openings, pressure relief, valves, insulation, degree of filling and electrical continuity. This means the vessel is designed as a complete system, not only as a shell and head set.
- Clause 10.2.11 sets an electrical continuity limit of 5 ohms. That matters where bonding or static control is needed.
- Clause 10.3 provides the calculation rules for inner vessel, outer jacket, attachments, piping and accessories, including the formulas for cylindrical shells, spheres, cones, flat ends and openings. Engineers use this section to size the pressure-retaining parts and check local reinforcement.
- Annex B gives rules for elastic stress analysis under operating loads, including stress categories and allowable limits. If a finite element or similar analysis is used, Annex B is the reference for how to judge the results.
- Annex H and Annex I give calculation methods for external pressure and openings, and the standard says the methods in those annexes are equally accepted. That gives the designer a choice of calculation route while keeping the acceptance basis fixed.
- Annex C adds specific requirements for 9 % Ni steel, and Annex D gives a pressure-strengthening route for austenitic stainless steels within the stated application limits. These annexes matter when the vessel uses a special material or when the manufacturer wants to use strengthening as part of the design approach.
- Annex F covers outer-jacket relief devices. This is important because the vacuum jacket also needs pressure protection, not only the inner vessel.
Fabrication, inspection and acceptance
- Clause 11 requires suitable equipment, controlled cutting and forming, manufacturing tolerances, welding qualification and qualified non-welded joints. In practice, the manufacturer has to control the work process, not just the final dimensions.
- Clause 12 requires a quality plan, production control test plates, non-destructive testing, rectification and pressure testing. Repaired welds must be examined and tested again to the original acceptance standard.
- Clause 12.5 requires every inner vessel to be pressure tested, the piping system to be tested at the pressure tied to the design load, and leakproofness testing where applicable. This is the final proof that the vessel is tight and fit for service.
- Clause 13 requires marking on a corrosion-resistant metal plate permanently attached to the outer jacket in a visible and accessible position. The marking must include the size limitations for operation and transportation mode.
- Clauses 14 and 15 connect the final acceptance test and periodic inspection to dated stamps by the expert or inspector. Clause 16 requires delivery of conformity documents, a short vessel description, the list of fluids and net mass, and a user operating manual with normal-operation instructions.
What terms does ISO 20421-1 define?
- Cryogenic fluid - a gas that is partially liquid because of its low temperature; in this document, it also includes totally evaporated liquids and supercritical fluids.
- Large transportable cryogenic vessel - a thermally insulated vessel of more than 450 l for transporting one or more cryogenic fluids, complete with the inner vessel, outer jacket, valves, service equipment and structural parts.
- Inner vessel - the pressure vessel intended to contain the cryogenic fluid.
- Outer jacket - the gas-tight enclosure around the inner vessel that allows the vacuum to be established.
- Operating load - the load exerted during normal transport conditions, including loading, unloading, moving and lifting.
- Maximum allowable working pressure - the maximum gauge pressure permitted at the top of the vessel in its normal operating position.
- Pressure-strengthened vessel - a pressure vessel that has been intentionally pressurized after completion so that its wall thickness is based on the strengthening stress rather than the conventional design stress value.
- Leakproofness test - a gas test applied to the shell and service equipment at an effective internal pressure not less than 90 % of the maximum allowable working pressure and not greater than the design pressure.
Who uses ISO 20421-1?
ISO 20421-1 is used by manufacturers of cryogenic transport tanks, design engineers, welding coordinators, NDT personnel, inspection bodies and competent authorities. It is also used by owners, operators and buyers who need to check whether a vessel is suitable for a transport application, what documents should be delivered, and how final acceptance and periodic inspection are handled.
Typical tasks include:
- designing the inner vessel, outer jacket, supports, piping and relief systems
- selecting materials for cryogenic compatibility and toughness
- qualifying welding and inspection procedures
- checking pressure testing, leakproofness and marking
- preparing acceptance, service and periodic inspection records
What changed in ISO 20421-1 from the previous edition?
ISO 20421-1 is the third edition and it replaces ISO 20421-1:2019, including Amendment 1:2022. The changes stated in the foreword are:
- Clause 12.3 was revised
- load factors for normal operation in fatigue analysis were corrected for specified transportation modes in Table 2
- loads for piping and valves were divided for road/water and rail conditions in 10.2.3.11
- Table 3 was corrected
- the material property K used in 10.3.2.3.1 was corrected for calculations considering ADR/RID/IMDG-Code/49CFR
- material Table D.1 was split into European Material Table D.1 and Non-European Material Table D.2
- requirements for testing plates under cold strengthening were corrected in Table D.3
- Table J.1 was corrected considering ADR/RID/IMDG-Code/49CFR
Which standards are used with ISO 20421-1?
ISO 20421-1 relies on a set of welding, testing, materials and cryogenic-service standards to support fabrication and validation.
| Reference | What it contributes |
|---|---|
| ISO 3834-2 | Comprehensive quality requirements for fusion welding |
| ISO 4126-2 | Bursting disc safety devices |
| ISO 5817, ISO 10042 | Quality levels for weld imperfections |
| ISO 9606-1, ISO 9606-2 | Welder qualification |
| ISO 9712 | Qualification and certification of NDT personnel |
| ISO 10474 | Inspection documents for steel and steel products |
| ISO 10675-1, ISO 10675-2 | Acceptance levels for radiographic testing |
| ISO 14732 | Qualification of welding operators and weld setters |
| ISO 15613, ISO 15614-1, ISO 15614-2 | Welding procedure qualification |
| ISO 17635, ISO 17637, ISO 17636-1, ISO 3452-1, ISO 23277 | NDT rules, visual testing, radiography and penetrant testing acceptance |
| ISO 20421-2 | Operational requirements for the vessels after fabrication |
| ISO 21010 | Gas/material compatibility |
| ISO 21011 | Cryogenic service valves |
| ISO 21013-1, ISO 21013-2, ISO 21013-3 | Pressure-relief accessories and their sizing |
| ISO 21028-1, ISO 21028-2 | Toughness requirements at cryogenic temperature |
| ISO 23208 | Cleanliness for cryogenic service |
| ASME VIII-2, EN 13445-3 | Alternative pressure-vessel design rules used for comparison or calculation support |
What does the ISO 20421-1 document contain?
ISO 20421-1 contains a symbol list, design formulas, fabrication rules, inspection and test requirements, and annexes with worked calculation methods and examples. The document includes formulas and figures for shells, spheres, cones, flat ends, openings, reinforcement and operating-load checks, plus procedures for welding, non-welded joints, quality plans, non-destructive testing, pressure testing and leakproofness testing.
It also includes example tank plates in Annex A, elastic stress analysis in Annex B, special material and weld rules for 9 % Ni steel in Annex C, pressure-strengthening rules in Annex D, weld details in Annex E, outer-jacket relief devices in Annex F, calculation methods for external pressure in Annex H and openings in Annex I, and equivalent-thickness methods in Annex J. Annex K lists the refrigerated liquefied gases referred to by the standard.
Relations
- Effective Date
- 12-Feb-2026
- Effective Date
- 24-Jun-2023
- Effective Date
- 24-Jun-2023
Buy Documents
ISO/FDIS 20421-1 - Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing
REDLINE ISO/FDIS 20421-1 - Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing
ISO/FDIS 20421-1 - Récipients cryogéniques — Grands récipients transportables isolés sous vide — Partie 1: Conception, fabrication, inspection et essais
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
ISO 20421-1 is a draft published by the International Organization for Standardization (ISO). Its full title is "Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 1: Design, fabrication, inspection and testing". This standard covers: This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport. This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids. This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.
This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport. This document applies to large transportable vacuum-insulated cryogenic vessels for fluids specified in 3.1 and does not apply to vessels designed for toxic fluids. This document does not include the general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE 1 This document does not cover specific requirements for refillable liquid-hydrogen tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in land vehicles, see ISO 13985. NOTE 2 This document does not cover specific requirements for refillable liquid hydrogen and LNG tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.
ISO 20421-1 is classified under the following ICS (International Classification for Standards) categories: 23.020.40 - Cryogenic vessels. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 20421-1 has the following relationships with other standards: It is inter standard links to FprEN ISO 20421-1, ISO 20421-1:2019, ISO 20421-1:2019/Amd 1:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 20421-1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 cryogenic fluid
- 3.2 large transportable cryogenic vessel
- 3.3 insulation
- 3.4 inner vessel
- 3.5 outer jacket
- 3.6 normal operation
- 3.7 operating load
- 3.8 piping system
- 3.9 service equipment
- 3.10 manufacturer
- 3.11 gross volume
- 3.12 tare mass
- 3.13 net volume
- 3.14 net mass
- 3.15 gross mass
- 3.16 pressure
- 3.17 fixed tank
- 3.18 demountable tank
- 3.19 portable tank
- 3.20 maximum allowable working pressure
- 3.21 relief plate
- 3.22 bursting disc device
- 3.23 pressure-strengthened vessel
- 3.24 residual elongation
- 3.25 leakproofness test
- 4 Symbols
- 5 General requirements
- 5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting
- 6 Mechanical loads
- 6.1 General
- 6.2 Load during the pressure test
- 7 Chemical effects
- 8 Thermal conditions
- 9 Materials
- 9.1 Selection of materials
- 9.2 Inspection documentation
- 10 Design
- 10.1 Design options
- 10.2 Common design requirements
- 10.3 Design by calculation
- 15 K
- 11 Fabrication
- 11.1 General
- 11.2 Cutting
- 11.3 Cold forming
- 11.4 Hot forming
- 11.5 Manufacturing tolerances
- 11.6 Welding
- 11.7 Non-welded joints
- 12 Inspection and testing
- 12.1 Quality plan
- 12.2 Production control test plates
- 12.3 Non-destructive testing
- 12.4 Rectification
- 12.5 Pressure testing
- 13 Marking and labelling
- 14 Final acceptance test
- 15 Periodic inspection
- 16 Documentation
- Annex A
- 15 Month and year of the pressure test of the inner vessel
- 16 Stamp of the inspector who witnessed the pressure test
- Annex B
- Annex C
- Annex D
- 1 T (at T=20 °C) R ≥ σ ; A ≥ 25 %
- 3 IW (at T ) 40 J/cm (0,38 mm)
- Annex E
- Annex F
- Annex G
- Annex H
- Annex I
- 10 A 2 S
- Annex J
- Annex K
- Bibliography
1 Scope
This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport.
This document applies to large transportable vacuum-insulated cryogenic vessels for fluids and does not apply to vessels designed for toxic fluids.
This document does not specify general vehicle requirements, e.g. running gear, brakes, lighting. NOTE This document does not cover specific requirements for refillable liquid hydrogen and liquified natural gas (LNG) tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3834-2, Quality requirements for fusion welding of metallic materials — Part 2: Comprehensive quality requirements ISO 4126-2, Safety devices for protection against excessive pressure — Part 2: Bursting disc safety devices ISO 5817, Welding — Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) — Quality levels for imperfections ISO 9606-1, Qualification testing of welders — Fusion welding — Part 1: Steels ISO 9606-2, Qualification test of welders — Fusion welding — Part 2: Aluminium and aluminium alloys ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel ISO 10042, Welding — Arc-welded joints in aluminium and its alloys — Quality levels for imperfections ISO 10474:2013, Steel and steel products — Inspection documents ISO 10675-1, Non-destructive testing of welds — Acceptance levels for radiographic testing — Part 1: Steel, nickel, titanium and their alloys ISO 10675-2, Non-destructive testing of welds — Acceptance levels for radiographic testing — Part 2: Aluminium and its alloys ISO 14732, Welding personnel — Qualification testing of welding operators and weld setters for mechanized and automatic welding of metallic materials
ISO/FDIS 20421-1:2026(en) ISO 15613, Specification and qualification of welding procedures for metallic materials — Qualification based on a pre-production welding test ISO 15614-1, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys ISO 15614-2, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 2: Arc welding of aluminium and its alloys ISO 17635, Non-destructive testing of welds — General rules for metallic materials ISO 17637, Non-destructive testing of welds — Visual testing of fusion-welded joints ISO 20421-2, Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 2: Operational requirements ISO 21010, Cryogenic vessels — Gas/material compatibility ISO 21011, Cryogenic vessels — Valves for cryogenic service ISO 21028-1, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 1:
Temperatures below -80 °C ISO 21028-2, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 2:
Temperatures between ‒80 degrees C and ‒20 degrees C ISO 21013-1, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 1: Reclosable pressurerelief valves ISO 21013-2, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 2: Non-reclosable pressure-relief devices ISO 21013-3, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 3: Sizing and capacity determination ISO 23208, Cryogenic vessels — Cleanliness for cryogenic service ISO 17636-1, Non-destructive testing of welds — Radiographic testing — Part 1: X- and gamma-ray techniques with film ISO 23277, Non-destructive testing of welds — Penetrant testing — Acceptance levels ASME VIII-2, Rules for construction of pressure vessels, Division 2, Alternative Rules EN 13445-3, Unfired pressure vessels — Part 3: Design
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 cryogenic fluid
gas which is partially liquid because of its low temperature Note 1 to entry: This includes totally evaporated liquids and supercritical fluids. Note 2 to entry: In the context of this document, the refrigerated but non-toxic gases and gas mixtures given in Table K.1 are referred to as cryogenic fluids.
ISO/FDIS 20421-1:2026(en)
3.2 large transportable cryogenic vessel
thermally insulated vessel of more than 450 l intended for the transport of one or more cryogenic fluids (3.1), consisting of an inner vessel (3.4), an outer jacket (3.5), all of the valves and service equipment (3.9) together with the structural parts Note 1 to entry: The large transportable cryogenic vessel comprises a complete assembly that is ready for service. Note 2 to entry: Large transportable cryogenic vessels are equivalent to large transportable cryogenic tanks.
3.3 insulation
vacuum interspace between the inner vessel (3.4) and the outer jacket (3.5) Note 1 to entry: The space can be filled with material to reduce the heat transfer between the inner vessel and the outer jacket.
3.4 inner vessel
pressure (3.16) vessel intended to contain the cryogenic fluid (3.1) to be transported
3.5 outer jacket
gas-tight enclosure which contains the inner vessel (3.4) and enables the vacuum to be established
3.6 normal operation
intended operation of the vessel at a pressure (3.16) not greater than the maximum allowable working pressure (3.20) including the handling loads
3.7 operating load
load exerted on the transportable cryogenic vessel in all normal conditions of transport including loading, unloading, moving and lifting
3.8 piping system
all pipes, tubes and associated components which can come in contact with cryogenic fluids (3.1) including valves, fittings, pressure-relief devices and their supports
3.9 service equipment
measuring instruments and filling, discharge, venting, safety, heating, cooling and insulating devices including any equipment for storing cooling fluids
3.10 manufacturer
<large transportable cryogenic vessel> company that carries out the final assembly, including the final acceptance test, of the large transportable cryogenic vessel (3.2)
3.11 gross volume
<of the inner vessel> internal volume of the inner vessel (3.4), excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)
3.12 tare mass
mass of the empty large transportable cryogenic vessel (3.2)
ISO/FDIS 20421-1:2026(en)
3.13 net volume
volume of the inner vessel (3.4), below the inlet to the relief devices, excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)
3.14 net mass
maximum allowable mass of the cryogenic fluid (3.1) which may be filled Note 1 to entry: The maximum allowable mass is equal to the mass of the cryogenic liquid occupying 98 % of the net volume (3.13) of the inner vessel (3.4) under conditions of incipient opening of the relief device with the vessel in a level attitude and the mass of the gas at the same conditions in the remaining volume of the inner vessel. Note 2 to entry: Cryogenic liquid helium can occupy 100 % of the volume of the inner vessel at any pressure (3.16).
3.15 gross mass
sum of tare mass (3.12) and net mass (3.14)
3.16 pressure
gauge pressure pressure relative to atmospheric pressure
3.17 fixed tank
large transportable (cryogenic) vessel having a capacity of more than 1 000 litres which is permanently attached to a vehicle (which then becomes a tank-vehicle) or is an integral part of the frame of such vehicle
3.18 demountable tank
large transportable vessel non-permanently attached to a vehicle Note 1 to entry: When attached to the carrier vehicle, the demountable tank meets the requirements prescribed for a fixed tank (3.17). It is designed to be lifted only when empty.
3.19 portable tank
thermally insulated multimodal tank having a capacity of more than 450 litres fitted with service equipment (3.9) and structural equipment necessary for the carriage of refrigerated liquefied gases Note 1 to entry: It can be lifted full and loaded and discharged without removal of structural element. Note 2 to entry: The list of the refrigerated liquefied gases is available in Annex K.
3.20 maximum allowable working pressure
p s maximum gauge pressure (3.16) permissible at the top of the vessel in its normal operating position
3.21 relief plate
relief plug plate or plug retained by atmospheric pressure (3.16) which allows relief of excess internal pressure, generally from the vacuum jacket
3.22 bursting disc device
non-reclosing pressure-relief device ruptured by differential pressure (3.16) Note 1 to entry: It is the complete assembly of installed components including the bursting disc holder, where appropriate.
ISO/FDIS 20421-1:2026(en)
3.23 pressure-strengthened vessel
pressure vessel which has been subjected to a calculated and controlled internal pressure (strengthening pressure) after completion, the wall thickness of which is calculated on the basis of the stress at the strengthening pressure and not on the basis of the conventional design stress value of the material used Note 1 to entry: Pressure (3.16) vessels made from solution heat-treated material are subject to a controlled plastic deformation during the strengthening operation as its yield point is raised. Pressure vessels made from work-hardened material are subject to little or no plastic deformation.
3.24 residual elongation
original elongation of the steel minus the elongation created by the cold-forming deformation
3.25 leakproofness test
test using gas subjecting the shell and its service equipment (3.9), to an effective internal pressure (3.16) not less than 90 % of the maximum allowable working pressure but not greater than the design pressure
4 Symbols
Symbol Definition Unit b width of pad, ring or shell reinforcement mm c allowance for corrosion mm d distance mm d diameter of opening mm
d outside diameter of tube or nozzle mm a f narrow side of rectangular or elliptical plate mm l cone length between effective stiffenings (see Figure 5) mm
l ligament (web) between two nozzles mm l l′ buckling length mm b, b l length of nozzle reinforcement outstanding mm s n number of lobes — p design pressure as defined in 10.3.2.2 — p calculation pressure as defined in 10.2.3.2.1 a) bar
p allowable external pressure limited by elastic buckling bar e p strengthening pressure bar k p liquid pressure bar L p allowable external pressure limited by plastic deformation bar p p maximum allowable gauge pressure bar s p test pressure (see 6.2) bar T r radius, e.g. inside knuckle radius of dished end and cones mm s minimum thickness mm s required wall thickness at opening edge mm A s actual wall thickness mm e s required wall thickness outside corner area mm g s thickness of nozzle reinforcement in stand mm n s wall thickness of nozzle mm s s required wall thickness within corner area mm
t in this context, centre-to-centre distance between two nozzles mm x (decay-length zone) distance over which governing stress is assumed to act mm
ISO/FDIS 20421-1:2026(en) Symbol Definition Unit x characteristic lengths (i = 1,2,3) to define corner area [Figure 10 a) and mm
Figure 10 b) and 10.3.6.5.4] η factor indicative of the utilization of the permissible design stress in joints or — factor allowing for weakenings
A cross-sectional area of reinforcing element mm C, β design factors — D shell diameter mm D outside diameter, e.g. of a cylindrical shell mm a D outside diameter of connected cylinder (see Figure 10) mm a1 D outside diameter at effective stiffening (see Figure 12) mm a2 D internal diameter, e.g. of a cylindrical shell mm
D design diameter (see Figure 10) mm k D shell diameter at nozzle (see Figure 11) mm s
E Young’s modulus N/mm G Gravity point —
I moment of inertia of reinforcing element mm
R minimum guaranteed yield stress or 0,2 % proof stress at 20 °C (1 % proof N/mm e stress for austenitic steel)
R minimum guaranteed tensile strength at 20 °C N/mm m
R minimum guaranteed yield strength with 1,0 % plastic deformation N/mm p1,0
K material property used for design (see 10.3.2.3) N/mm
K material property at temperature T in °C (e.g. K for material property at 20 °C N/mm T 20 (see 10.3.2.3.2) R radius of curvature, e.g. inside crown radius of dished end mm S safety factor at design pressure, in relation with R — e S safety factor against elastic buckling at design pressure — k S safety factor against plastic deformation — p Z auxiliary value — v Poisson’s ratio — u out of roundness (see 11.5.5.2) — φ cone angle °
σ design stress value (strengthening stress value in Annex D) N/mm k
5 General requirements
5.1 Large transportable cryogenic vessels shall safely withstand the mechanical and thermal loads and the chemical effects encountered during pressure test and normal operation. These requirements are deemed to be satisfied if Clauses 6 to 12 are fulfilled. The vessel shall be marked in accordance with Clause 13, tested in accordance with Clause 14 and operated in accordance with ISO 20421-2. 5.2 Large transportable cryogenic vessels shall be configured in such a way that the vessel can be operated safely (e.g. valves, pressure-relief devices). The number of openings in the inner vessel for this equipment shall be kept to a minimum.
5.3 Large transportable cryogenic vessel shall be clean for the intended service in accordance with ISO 23208.
5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting
documentation (including that from his subcontractors, if any), for a required period (e.g. product liability).
ISO/FDIS 20421-1:2026(en) In addition, the manufacturer shall retain all supporting and background documentation (including that from his subcontractors, if any) which establishes that the vessel conforms to this document.
6 Mechanical loads
6.1 General
The large transportable cryogenic vessel shall resist the mechanical loads mentioned in 10.2.3 without such deformation which can affect safety and which can lead to leakage. This requirement can be validated by:
- the calculation;
- the calculation and pressure-strengthening method, if allowed;
- the calculation and experimental method.
6.2 Load during the pressure test
The load exerted during the pressure test shall be calculated with Formula (1):
pp13, 1 (1)
Ts where p is the test pressure (in bar); T P is the maximum allowable pressure (in bar); s +1 is the allowance for external vacuum (in bar).
7 Chemical effects
Due to operating temperatures and the materials of construction, the possibility of chemical action on the inner surfaces in contact with the cryogenic fluids can be neglected. Due to the fact that the inner vessel is inside an evacuated outer jacket, neither external corrosion of the inner vessel, nor corrosion on the inner surfaces of the outer jacket will occur. Therefore, inspection openings are not required in the inner vessel or the outer jacket.
Corrosion allowance is also not required on surfaces in contact with the operating fluid or exposed to the vacuum interspace between the inner vessel and the outer jacket. The material and the protection for the surfaces exposed to the atmosphere shall be suitable for intended use (e.g. resistant to industrial and marine atmospheres).
8 Thermal conditions
The following thermal conditions shall be taken into account:
- for the inner vessel and its associated equipment, the full range of temperature expected;
- for the outer jacket and equipment thereof (other than equipment covered in Clause 7):
- a minimum working temperature of −20 °C;
- a maximum working temperature of 50 °C.
NOTE 1 Some locations require lower minimum working temperature e.g. –40 °C and/or higher maximum working temperature, e.g. +65 °C.
NOTE 2 This does not apply if the jacket is designed for a lower temperature to be marked on the nameplate.
ISO/FDIS 20421-1:2026(en)
9 Materials
9.1 Selection of materials
9.1.1 Materials which are, or can be, in contact with cryogenic fluids shall be in accordance with ISO 21010. 9.1.2 Materials used at low temperatures shall follow the requirements of the relevant clauses of ISO 21028-1 and ISO 21028-2; for non-metallic materials, low-temperature suitability shall be validated by an experimental method, taking into account operating temperatures. 9.1.3 The base materials, listed in Annex G, subject to meeting the extra requirements given in Clauses 5 to 16, are suitable for and may be employed in the manufacture of the cryogenic vessels, in conformance with this document.
9.2 Inspection documentation
9.2.1 The material according to ISO 21028-1 and ISO 21028-2 shall be declared by an inspection certificate 3.1 in accordance with ISO 10474:2013, 5.1.
9.2.2 The material manufactured to a recognized International Standard shall meet the testing
requirements of ISO 21028-1 and ISO 21028-2 and shall be declared by an inspection certificate 3.1 in accordance with ISO 10474:2013, 5.1.
9.2.3 The delivery of material which is not manufactured to a recognized International Standard shall be guaranteed by an inspection certificate 3.2 in accordance with ISO 10474:2013, 5.2 confirming that the material fulfils the requirements in 9.1. The material manufacturer shall follow a recognized International Standard for processing and establishing the guaranteed material properties. 9.2.4 The outer jacket and the equipment not subjected to low temperature shall be manufactured from material suitable for the intended service.
10 Design
10.1 Design options
10.1.1 General
The design shall be carried out in accordance with one of the options given in 10.1.2, 10.1.3 or 10.1.4. Metallic materials used at cryogenic temperatures shall meet the requirements of the relevant clauses of ISO 21028-1 and ISO 21028-2.
In the case of 9 % Ni steel, the additional requirements in Annex C shall be satisfied.
10.1.2 Design by calculation
Calculation of all pressure-bearing and load-bearing components shall be carried out. The pressure part thicknesses of the inner vessel and outer jacket shall not be less than required by 10.3. Additional calculations are required to ensure the design is satisfactory for the operating conditions including an allowance for dynamic loads.
10.1.3 Design by calculation and pressure strengthening
The pressure-retaining capability of inner vessels manufactured from austenitic stainless steel, strengthened by pressure, shall be calculated in accordance with Annex D.
ISO/FDIS 20421-1:2026(en)
10.1.4 Design of components by calculation supplemented with experimental methods
Where it is not possible to design non-inner vessel components by calculation alone, planned and controlled experimental means may be used provided that the results confirm the safety factors required in 10.3. An example is the application of strain gauges to assess stress levels.
...
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 cryogenic fluid
- 3.2 large transportable cryogenic vessel
- 3.3 insulation
- 3.4 inner vessel
- 3.5 outer jacket
- 3.6 normal operation
- 3.7 operating load
- 3.8 piping system
- 3.9 service equipment
- 3.11 gross volume
- 3.12 tare mass
- 3.13 net volume
- 3.14 net mass
- 3.15 gross mass
- 3.16 pressure
- 3.17 fixed tank
- 3.18 demountable tank
- 3.19 portable tank
- 3.20 maximum allowable working pressure
- 3.21 relief plate
- 3.22 bursting disc device
- 3.23 pressure-strengthened vessel
- 3.24 residual elongation
- 3.25 leakproofness test
- 4 Symbols
- 5 General requirements
- 5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting
- 6 Mechanical loads
- 6.1 General
- 6.2 Load during the pressure test
- 7 Chemical effects
- 8 Thermal conditions
- 9 Materials
- 9.1 Selection of materials
- 9.2 Inspection documentation
- 10 Design
- 10.1 Design options
- 10.2 Common design requirements
- 10.3 Design by calculation
- 15 K ×η
- 15 K ×η
- 11 Fabrication
- 11.1 General
- 11.2 Cutting
- 11.3 Cold forming
- 11.4 Hot forming
- 11.5 Manufacturing tolerances
- 11.6 Welding
- 11.7 Non-welded joints
- 12 Inspection and testing
- 12.1 Quality plan
- 12.2 Production control test plates
- 12.3 Non-destructive testing
- 12.4 Rectification
- 12.5 Pressure testing
- 13 Marking and labelling
- 14 Final acceptance test
- 15 Periodic inspection
- 16 Documentation
- Annex A
- 15 Month and year of the pressure test of the inner vessel
- 16 Stamp of the inspector who witnessed the pressure test
- Annex B
- Annex C
- Annex D
- 1 T (at T=20 °C) R ≥ σ ; A ≥ 25 %
- 1 Ma (not pre-
- 3 IW (at T ) 40 J/cm (0,38 mm)
- 1 T (at T=20 °C) R ≥ σ ; A ≥ 25 %
- 1 Ma (not pre-
- Annex E
- Annex F
- Annex G
- Annex H
- Annex I
- Annex J
- Annex K
1 Scope
This document specifies requirements for the design, fabrication, inspection and testing of large transportable vacuum-insulated cryogenic vessels of more than 450 l volume, which are permanently (fixed tanks) or not permanently (demountable tanks and portable tanks) attached to a means of transport, for one or more modes of transport.
This document applies to large transportable vacuum-insulated cryogenic vessels for fluids and does not apply to vessels designed for toxic fluids.
This document does not specify general vehicle requirements, e.g. running gear, brakes, lighting, etc. NOTE This document does not cover specific requirements for refillable liquid hydrogen and liquified natural gas (LNG) tanks that are primarily dedicated as fuel tanks in vehicles. For fuel tanks used in vehicles, see ISO 13985.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3834-2, Quality requirements for fusion welding of metallic materials — Part 2: Comprehensive quality requirements ISO 4126-2, Safety devices for protection against excessive pressure — Part 2: Bursting disc safety devices ISO 5817, Welding — Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) — Quality levels for imperfections ISO 9606-1, Qualification testing of welders — Fusion welding — Part 1: Steels ISO 9606-2, Qualification test of welders — Fusion welding — Part 2: Aluminium and aluminium alloys ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel ISO 10042, Welding — Arc-welded joints in aluminium and its alloys — Quality levels for imperfections ISO 10474:2013, Steel and steel products — Inspection documents ISO 10675-1, Non-destructive testing of welds — Acceptance levels for radiographic testing — Part 1: Steel, nickel, titanium and their alloys ISO 10675--2, Non-destructive testing of welds — Acceptance levels for radiographic testing — Part 2:
Aluminium and its alloys ISO 14732, Welding personnel — Qualification testing of welding operators and weld setters for mechanized and automatic welding of metallic materials
ISO/FDIS 20421-1:2026(en) ISO 15613, Specification and qualification of welding procedures for metallic materials — Qualification based on a pre-production welding test ISO 15614-1, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys ISO 15614-2, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 2: Arc welding of aluminium and its alloys ISO 17635, Non-destructive testing of welds — General rules for metallic materials ISO 17637, Non-destructive testing of welds — Visual testing of fusion-welded joints ISO 20421-2, Cryogenic vessels — Large transportable vacuum-insulated vessels — Part 2: Operational requirements ISO 21010, Cryogenic vessels — Gas/material compatibility ISO 21011, Cryogenic vessels — Valves for cryogenic service ISO 21028-1, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 1: Temperatures below -80 degrees °C ISO 21028-2, Cryogenic vessels — Toughness requirements for materials at cryogenic temperature — Part 2: Temperatures between -‒80 degrees C and -‒20 degrees C ISO 21013-1, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 1: Reclosable pressure-relief valves ISO 21013-2, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 2: Non-reclosable pressure-relief devices ISO 21013-3, Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 3: Sizing and capacity determination ISO 23208, Cryogenic vessels — Cleanliness for cryogenic service Non-destructive testing of welds — Radiographic testing — Part 1: X- and gamma-ray ISO 17636--1, techniques with film ISO 3452-1, Non-destructive testing — Penetrant testing — Part 1: General principles ISO 23277, Non-destructive testing of welds — Penetrant testing — Acceptance levels ASME VIII-2, Rules for construction of pressure vessels, Division 2, Alternative Rules EN 13445-3, Unfired pressure vessels — Part 3: Design
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
ISO/FDIS 20421-1:2026(en)
3.1 cryogenic fluid
gas which is partially liquid because of its low temperature Note 1 to entry: This includes totally evaporated liquids and supercritical fluids. Note 2 to entry: In the context of this document, the refrigerated but non-toxic gases and gas mixtures given in Table K.1 are referred to as cryogenic fluids.
3.2 large transportable cryogenic vessel
thermally insulated vessel of more than 450 l intended for the transport of one or more cryogenic fluids (3.1), consisting of an inner vessel (3.4), an outer jacket (3.5), all of the valves and service equipment (3.9) together with the structural parts Note 1 to entry: The large transportable cryogenic vessel comprises a complete assembly that is ready for service. Note 2 to entry: Large transportable cryogenic vessels are equivalent to large transportable cryogenic tanks.
3.3 insulation
vacuum interspace between the inner vessel (3.4) and the outer jacket (3.5) Note 1 to entry: The space can be filled with material to reduce the heat transfer between the inner vessel and the outer jacket.
3.4 inner vessel
pressure (3.16) vessel intended to contain the cryogenic fluid (3.1) to be transported
3.5 outer jacket
gas-tight enclosure which contains the inner vessel (3.4) and enables the vacuum to be established
3.6 normal operation
intended operation of the vessel at a pressure (3.16) not greater than the maximum allowable working pressure (3.20) including the handling loads (3.7)
3.7 operating load
load exerted on the transportable cryogenic vessel in all normal conditions of transport including loading, unloading, moving and lifting
3.8 piping system
all pipes, tubes and associated components which can come in contact with cryogenic fluids (3.1) including valves, fittings, pressure-relief devices and their supports
3.9 service equipment
measuring instruments and filling, discharge, venting, safety, heating, cooling and insulating devices including any equipment for storing cooling fluids 3.10
ISO/FDIS 20421-1:2026(en) manufacturer <large transportable cryogenic vessel> company that carries out the final assembly, including the final acceptance test, of the large transportable cryogenic vessel (3.2)
3.11 gross volume
<of the inner vessel> internal volume of the inner vessel (3.4), excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)
3.12 tare mass
mass of the empty large transportable cryogenic vessel (3.2)
3.13 net volume
volume of the inner vessel (3.4), below the inlet to the relief devices, excluding nozzles, pipes, etc., determined at minimum design temperature and atmospheric pressure (3.16)
3.14 net mass
maximum allowable mass of the cryogenic fluid (3.1) which may be filled Note 1 to entry: The maximum allowable mass is equal to the mass of the cryogenic liquid occupying 98 % of the net volume (3.13) of the inner vessel (3.4) under conditions of incipient opening of the relief device with the vessel in a level attitude and the mass of the gas at the same conditions in the remaining volume of the inner vessel. Note 2 to entry: Cryogenic liquid helium can occupy 100 % of the volume of the inner vessel at any pressure (3.16).
3.15 gross mass
sum of tare mass (3.12) plus and net mass (3.14)
3.16 pressure
gauge pressure pressure relative to atmospheric pressure
3.17 fixed tank
large transportable (cryogenic) vessel having a capacity of more than 1 000 litres which is permanently attached to a vehicle (which then becomes a tank-vehicle) or is an integral part of the frame of such vehicle 3.18
3.18 demountable tank
large transportable vessel non-permanently attached to a vehicle Note 1 to entry: When attached to the carrier vehicle, the demountable tank meets the requirements prescribed for a fixed tank (3.17). It is designed to be lifted only when empty.
3.19 portable tank
thermally insulated multimodal tank having a capacity of more than 450 litres fitted with service equipment (3.9) and structural equipment necessary for the carriage of refrigerated liquefied gases
ISO/FDIS 20421-1:2026(en) Note 1 to entry: It can be lifted full and loaded and discharged without removal of structural element. Note 2 to entry: The list of the refrigerated liquefied gases is available in Annex K.
3.20 maximum allowable working pressure
p s maximum gauge pressure (3.16) permissible at the top of the vessel in its normal operating position
3.21 relief plate
relief plug plate or plug retained by atmospheric pressure (3.16) which allows relief of excess internal pressure, generally from the vacuum jacket
3.22 bursting disc device
non-reclosing pressure-relief device ruptured by differential pressure (3.16) Note 1 to entry: It is the complete assembly of installed components including the bursting disc holder, where appropriate.
3.23 pressure-strengthened vessel
pressure vessel which has been subjected to a calculated and controlled internal pressure (strengthening pressure) after completion, the wall thickness of which is calculated on the basis of the stress at the strengthening pressure and not on the basis of the conventional design stress value of the material used Note 1 to entry: Pressure (3.16) vessels made from solution heat-treated material are subject to a controlled plastic deformation during the strengthening operation as its yield point is raised. Pressure vessels made from work-hardened material are subject to little or no plastic deformation.
3.24 residual elongation
original elongation of the steel minus the elongation created by the cold-forming deformation
3.25 leakproofness test
test using gas subjecting the shell and its service equipment (3.9), to an effective internal pressure (3.16) not less than 90 % of the maximum allowable working pressure but not greater than the design pressure
4 Symbols
Symbol Definition Unit b width of pad, ring or shell reinforcement mm c allowance for corrosion mm d distance mm d diameter of opening mm
d outside diameter of tube or nozzle mm a f narrow side of rectangular or elliptical plate mm lc cone length between effective stiffenings (see Figure 5) mm
ISO/FDIS 20421-1:2026(en) l ligament (web) between two nozzles mm lb, l′b buckling length mm l length of nozzle reinforcement outstanding mm s n number of lobes — p design pressure as defined in 10.3.2.2 — pc calculation pressure as defined in 10.2.3.2.1 a) bar p allowable external pressure limited by elastic buckling bar e pk strengthening pressure bar pL liquid pressure bar p allowable external pressure limited by plastic deformation bar p p maximum allowable gauge pressure bar s pT test pressure (see 6.2) bar r radius, e.g. inside knuckle radius of dished end and cones mm s minimum thickness mm s required wall thickness at opening edge mm A se actual wall thickness mm sg required wall thickness outside corner area mm s thickness of nozzle reinforcement in stand mm n Ssss wall thickness of nozzle mm s1 required wall thickness within corner area mm t in this context, centre-to-centre distance between two nozzles mm x (decay-length zone) distance over which governing stress is assumed to act mm xi characteristic lengths (i = 1,2,3) to define corner area [Figure 10 a) and mm Figure 10 b) and 10.3.6.5.4] η factor indicative of the utilization of the permissible design stress in joints or — factor allowing for weakenings
A cross-sectional area of reinforcing element mm C, β design factors — D shell diameter mm Da outside diameter, e.g. of a cylindrical shell mm Da1 outside diameter of connected cylinder (see Figure 10) mm D outside diameter at effective stiffening (see Figure 12) mm a2 D internal diameter, e.g. of a cylindrical shell mm
Dk design diameter (see Figure 10) mm Ds shell diameter at nozzle (see Figure 11) mm
E Young’s modulus N/mm G Gravity point —
I moment of inertia of reinforcing element mm
R minimum guaranteed yield stress or 0,2 % proof stress at 20 °C (1 % proof N/mm e stress for austenitic steel)
ISO/FDIS 20421-1:2026(en)
Rm minimum guaranteed tensile strength at 20 °C N/mm
Rp1,0 minimum guaranteed yield strength with 1,0 % plastic deformation N/mm
K material property used for design (see 10.3.2.3) N/mm
K material property at temperature T in °C (e.g. K for material property at N/mm T 20 20 °C (see 10.3.2.3.2) R radius of curvature, e.g. inside crown radius of dished end mm S safety factor at design pressure, in relation with R — e Sk safety factor against elastic buckling at design pressure — Sp safety factor against plastic deformation — Z auxiliary value — v Poisson’s ratio — u out of roundness (see 11.5.5.2) — φ cone angle °
σ design stress value (strengthening stress value in Annex D) N/mm k
5 General requirements
5.1 Large transportable cryogenic vessels shall safely withstand the mechanical and thermal loads and the chemical effects encountered during pressure test and normal operation. These requirements are deemed to be satisfied if Clauses 6 to 12 are fulfilled. The vessel shall be marked in accordance with Clause 13, tested in accordance with Clause 14 and operated in accordance with ISO 20421-2. 5.2 Large transportable cryogenic vessels shall be configured in such a way that the vessel can be operated safely (e.g. valves, pressure-relief devices). The number of openings in the inner vessel for this equipment shall be kept to a minimum.
5.3 Large transportable cryogenic vessel shall be clean for the intended service in accordance with ISO 23208.
5.4 The manufacturer shall retain the documents referred to in Clause 16, and all supporting
documentation (including that from his subcontractors, if any), for a required period (e.g. product liability). In addition, the manufacturer shall retain all supporting and background documentation (including that from his subcontractors, if any) which establishes that the vessel conforms to this document.
6 Mechanical loads
6.1 General
The large transportable cryogenic vessel shall resist the mechanical loads mentioned in 10.2.3 without such deformation which can affect safety and which can lead to leakage. This requirement can be validated by:
- the calculation;
- the calculation and pressure-strengthening method, if allowed;
- the calculation and experimental method.
ISO/FDIS 20421-1:2026(en)
6.2 Load during the pressure test
The load exerted during the pressure test shall be calculated with Formula (1):
pp≥ 13, + 1 𝑝𝑝 ≥ 1,3𝑝𝑝 + 1 baror (1)
T s Ts where p is the test pressure (in bar); T P is the maximum allowable pressure (in bar); s +1 is the allowance for external vacuum (in bar).
p is the test pressure (in bar); T P is the maximum allowable pressure (in bar); s +1 is the allowance for external vacuum (in bar).
7 Chemical effects
Due to operating temperatures and the materials of construction, the possibility of chemical action on the inner surfaces in contact with the cryogenic fluids can be neglected. Due to the fact that the inner vessel is inside an evacuated outer jacket, neither external corrosion of the inner vessel, nor corrosion on the inner surfaces of the outer jacket will occur. Therefore, inspection openings are not required in the inner vessel or the outer jacket. Corrosion allowance is also not required on surfaces in contact with the operating fluid or exposed to the vacuum interspace between the inner vessel and the outer jacket. The material and the protection for the surfaces exposed to the atmosphere shall be suitable for intended use (e.g. resistant to industrial and marine atmospheres).
8 Thermal conditions
The following thermal conditions shall be taken into account:
- for the inner vessel and its associated equipment, the full range of temperature expected;
- for the outer jacket and equipment thereof (other than equipment covered in Clause 7):
- a minimum working temperature of −20 °C;
- a maximum working temperature of 50 °C.
NOTE 1 Some locations require lower minimum working temperature e.g. –40 °C and/or higher maximum working temperature, e.g. +65 °C.
NOTE 2 This does not apply if the jacket is designed for a lower temperature to be marked on the nameplate.
9 Materials
9.1 Selection of materials
9.1.1 Materials which are, or can be, in contact with cryogenic fluids shall be in accordance with ISO 21010.
ISO/FDIS 20421-1:2026(en) 9.1.2 Materials used at low temperatures shall follow the requirements of the relevant partsclauses of ISO 21028-1 and ISO 21028-2; for non-metallic materials, low-temperature suitability shall be validated by an experimental method, taking into account operating temperatures. 9.1.3 The base materials, listed in Annex G, subject to meeting the extra requirements given in Clauses 5 to 16, are suitable for and may be employed in the manufacture of the cryogenic vessels, in conformance with this document.
9.2 Inspection documentation
9.2.1 The material according to ISO 21028-1 and ISO 21028-2 shall be declared by an inspection
certificate 3.1 in accordance with ISO 10474:2013, 5.1.
9.2.2 The material manufactured to a recognized International Standard shall meet the testing
requirements of ISO 21028-1 and ISO 21028-2 and shall be declared by an inspection certificate 3.1 in accordance with ISO 10474:2013, 5.1.
9.2.3 The delivery of material which is not manufactured to a recognized International Standard shall be guaranteed by an inspection certificate 3.2 in accordance with ISO 10474:2013, 5.2 confirming that the material fulfils the requirements in 9.1. The material manufacturer shall follow a recognized International Standard for processing and establishing the guaranteed material properties. 9.2.4 The outer jacket and the equipment not subjected to low temperature shall be manufactured from material suitable for the intended service.
10 Design
10.1 Design options
10.1.1 General
The design shall be carried out in accordance with one of the options given in 10.1.2, 10.1.3 or 10.1.4. Metallic materials used at cryogenic temperatures shall meet the requirements of the relevant clauses of ISO 21028-1 and ISO 21028-2.
In the case of 9 % Ni steel, the additional requirements in Annex C shall be satisfied.
10.1.2 Design by calculation
Calculation of all pressure-bearing and load-bearing components shall be carried out. The pressure part thicknesses of the inner vessel and outer jacket shall not be less than required by 10.3. Additional calculations are required to ensure the design is satisfactory for the operating conditions including an allowance for dynamic loads.
10.1.3 Design by calculation and pressure strengthening
The pressure-retaining capability of inner vessels manufactured from austenitic stainless steel, strengthened by pressure, shall be calculated in accordance with Annex D.
...
Contents
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 fluide cryogénique
- 3.2 grand récipient cryogénique transportable
- 3.3 isolation
- 3.4 récipient intérieur
- 3.5 enveloppe extérieure
- 3.6 fonctionnement normal
- 3.7 charge de fonctionnement
- 3.8 système de canalisations
- 3.9 équipement de service
- 3.10 fabricant
- 3.11 volume brut
- 3.12 tare
- 3.13 volume net
- 3.14 masse nette
- 3.15 masse brute
- 3.16 pression
- 3.17 citerne fixe
- 3.18 citerne démontable
- 3.19 citerne mobile
- 3.20 pression de service maximale admissible
- 3.21 plaque de décharge
- 3.22 dispositif à disque de rupture
- 3.23 récipient à pression renforcée
- 3.24 allongement résiduel
- 3.25 essai d'étanchéité
- 4 Symboles
- 5 Exigences générales
- 6 Charges mécaniques
- 6.1 Généralités
- 6.2 Charge pendant l'essai de pression
- 7 Effets chimiques
- 8 Conditions thermiques
- 9 Matériaux
- 9.1 Choix des matériaux
- 9.2 Documents de contrôle
- 10 Conception
- 10.1 Options de conception
- 10.2 Exigences générales de conception
- 10.3 Conception par calcul
- 15 K
- 11 Fabrication
- 11.1 Généralités
- 11.2 Découpe
- 11.3 Formage à froid
- 11.4 Formage à chaud
- 11.5 Tolérances de fabrication
- 11.6 Soudage
- 11.7 Assemblages non soudés
- 12 Inspection et essais
- 12.1 Plan qualité
- 12.2 Plaques d'essai de contrôle de la production
- 12.3 Essais non destructifs
- 12.4 Rectification
- 12.5 Essais de pression
- 13 Marquage et étiquetage
- 14 Essai de réception final
- 15 Inspection périodique
- 16 Documentation
- Annexe A
- Annexe B
- Annexe C
- Annexe D
- 1 T (avec T = 20 °C) R ≥ σ ; A ≥ 25 %
- 3 IW (à T ) 40 J/cm (0,38 mm)
- 1 T (avec T = 20 °C) R ≥ σ ; A ≥ 25 %
- Annexe E
- Annexe F
- Annexe G
- Annexe H
- Annexe I
- 10 A 2 S
- Annexe J
- Annexe K
- Bibliographie
1 Domaine d'application
Le présent document spécifie les exigences relatives à la conception, à la fabrication, à l'inspection et aux essais des grands récipients cryogéniques transportables isolés sous vide d'une contenance supérieure à 450 l, qui sont fixés à demeure (réservoirs fixes) ou non (réservoirs démontables et réservoirs portables) à un moyen de transport, pour un ou plusieurs modes de transport. Le présent document s'applique aux grands récipients cryogéniques transportables isolés sous vide utilisés pour les fluides et ne s'applique pas aux récipients conçus pour les fluides toxiques. Le présent document ne spécifie pas les exigences générales relatives aux véhicules, par exemple les trains de roulement, les freins, l'éclairage.
NOTE Le présent document ne couvre pas les exigences spécifiques applicables aux réservoirs d'hydrogène liquide et de gaz naturel liquéfié (GNL) rechargeables qui sont principalement utilisés comme réservoirs de carburant dans les véhicules. Pour les réservoirs de carburant utilisés dans les véhicules, voir l'ISO 13985.
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements). ISO 3834-2, Exigences de qualité en soudage par fusion des matériaux métalliques — Partie 2: Exigences de qualité complète ISO 4126-2, Dispositifs de sécurité pour protection contre les pressions excessives — Partie 2: Dispositifs de sûreté à disque de rupture ISO 5817, Soudage — Assemblages en acier, nickel, titane et leurs alliages soudés par fusion (soudage par faisceau exclu) — Niveaux de qualité par rapport aux défauts ISO 9606-1, Épreuve de qualification des soudeurs — Soudage par fusion — Partie 1: Aciers ISO 9606-2, Épreuve de qualification des soudeurs — Soudage par fusion — Partie 2: Aluminium et alliages d'aluminium ISO 9712, Essais non destructifs — Qualification et certification du personnel END ISO 10042, Soudage — Assemblages en aluminium et alliages d'aluminium soudés à l'arc — Niveaux de qualité par rapport aux défauts ISO 10474:2013, Aciers et produits sidérurgiques — Documents de contrôle ISO 10675-1, Essais non destructifs des assemblages soudés — Niveaux d'acceptation pour évaluation par radiographie — Partie 1: Acier, nickel, titane et leurs alliages
ISO/FDIS 20421-1:2026(fr) ISO 10675-2, Essais non destructifs des assemblages soudés — Niveaux d'acceptation pour évaluation par radiographie — Partie 2: Aluminium et ses alliages ISO 14732, Personnel en soudage — Épreuve de qualification des opérateurs soudeurs et des régleurs en soudage pour le soudage mécanisé et le soudage automatique des matériaux métalliques ISO 15613, Descriptif et qualification d'un mode opératoire de soudage pour les matériaux métalliques — Qualification sur la base d'un assemblage soudé de préproduction ISO 15614-1, Descriptif et qualification d’un mode opératoire de soudage pour les matériaux métalliques — Épreuve de qualification d’un mode opératoire de soudage — Partie 1: Soudage à l’arc et aux gaz des aciers et soudage à l’arc du nickel et des alliages de nickel ISO 15614-2, Descriptif et qualification d'un mode opératoire de soudage pour les matériaux métalliques — Épreuve de qualification d'un mode opératoire de soudage — Partie 2: Soudage à l'arc de l'aluminium et de ses alliages ISO 17635, Essais non destructifs des assemblages soudés — Règles générales pour les matériaux métalliques ISO 17637, Contrôle non destructif des assemblages soudés — Contrôle visuel des assemblages soudés par fusion ISO 20421-2, Récipients cryogéniques — Grands récipients transportables, isolés, sous vide — Partie 2: Exigences de fonctionnement ISO 21010, Récipients cryogéniques — Compatibilité gaz/matériaux ISO 21011, Récipients cryogéniques — Robinets pour usage cryogénique ISO 21028-1, Récipients cryogéniques — Exigences de ténacité pour les matériaux à température cryogénique - Partie 1: Températures inférieures à ‒80 °C ISO 21028-2, Récipients cryogéniques — Exigences de ténacité pour les matériaux à température cryogénique - Partie 2: Températures comprises entre -80 degrés C et -20 degrés C ISO 21013-1, Récipients cryogéniques — Dispositifs de sécurité pour le service cryogénique — Partie 1: Soupapes de sûreté pour service cryogénique ISO 21013-2, Récipients cryogéniques — Dispositifs de sécurité pour le service cryogénique — Partie 2:
Dispositifs de sécurité non refermables ISO 21013-3, Récipients cryogéniques — Dispositifs de sécurité pour le service cryogénique — Partie 3:
Détermination de la taille et du volume ISO 23208, Récipients cryogéniques — Propreté en service cryogénique ISO 17636-1, Essais non destructifs des assemblages soudés — Contrôle par radiographie — Partie 1: Techniques par rayons X ou gamma à l'aide de film ISO 23277, Contrôle non destructif des assemblages soudés — Contrôle par ressuage — Niveaux d'acceptation ASME VIII-2, Rules for construction of pressure vessels, Division 2, Alternative Rules EN 13445-3, Récipients sous pression non soumis à la flamme — Partie 3: Conception
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s'appliquent. L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l'adresse https:// www .iso .org/ obp
ISO/FDIS 20421-1:2026(fr) - IEC Electropedia: disponible à l'adresse https:// www .electropedia .org/
3.1 fluide cryogénique
gaz qui est partiellement liquide à cause de sa basse température Note 1 à l'article: Cela comprend les liquides totalement évaporés et les fluides supercritiques. Note 2 à l'article: Dans le contexte du présent document, les gaz et mélanges gazeux réfrigérés mais non toxiques indiqués dans le Tableau K.1 sont appelés “fluides cryogéniques”.
3.2 grand récipient cryogénique transportable
récipient isolé thermiquement d'une contenance supérieure à 450 l destiné au transport d'un ou plusieurs fluides cryogéniques (3.1), constitué d'un récipient intérieur (3.4), d'une enveloppe extérieure (3.5), de tous les robinets et équipement de service (3.9) ainsi que des éléments de structure Note 1 à l'article: Un grand récipient cryogénique transportable constitue un ensemble complet prêt à l'emploi. Note 2 à l'article: Les grands récipients cryogéniques transportables sont équivalents à de grandes citernes cryogéniques transportables.
3.3 isolation
espace de vide entre le récipient intérieur (3.4) et l'enveloppe extérieure (3.5) Note 1 à l'article: L'espace peut être rempli de matière pour réduire le transfert de chaleur entre le récipient intérieur et l'enveloppe extérieure.
3.4 récipient intérieur
récipient sous pression (3.16) destiné à contenir le fluide cryogénique (3.1) à transporter
3.5 enveloppe extérieure
enceinte étanche au gaz contenant le récipient intérieur (3.4) et permettant d'établir le vide
3.6 fonctionnement normal
fonctionnement prévu du récipient à une pression (3.16) ne dépassant pas la pression de service maximale admissible (3.20), en tenant compte des charges de manutention
3.7 charge de fonctionnement
charge exercée sur le récipient cryogénique transportable dans toutes les conditions normales de transport, notamment le chargement, le déchargement, le déplacement et le levage
3.8 système de canalisations
ensemble des tuyaux, tubes et composants associés pouvant entrer en contact avec des fluides cryogéniques (3.1), comprenant les robinets, raccords, dispositifs de décharge et leurs supports
3.9 équipement de service
instruments de mesure et dispositifs de remplissage, de vidange, d'évacuation, de sécurité, de chauffage, de refroidissement et d'isolation, comprenant tout équipement de stockage des fluides de refroidissement
3.10 fabricant
<grand récipient cryogénique transportable> entreprise qui effectue l'assemblage final, y compris l'essai de réception final, du grand récipient cryogénique transportable (3.2)
ISO/FDIS 20421-1:2026(fr)
3.11 volume brut
<du récipient intérieur> volume interne du récipient intérieur (3.4), à l'exclusion des piquages, tuyaux, etc., déterminé à une température de calcul minimale et à la pression (3.16) atmosphérique
3.12 tare
masse du grand récipient cryogénique transportable (3.2) vide
3.13 volume net
volume du récipient intérieur (3.4), sous l'entrée des dispositifs de décharge, à l'exclusion des piquages, tuyaux, etc., déterminé à une température de calcul minimale et à la pression (3.16) atmosphérique
3.14 masse nette
masse maximale admissible du fluide cryogénique (3.1) pouvant être rempli Note 1 à l'article: La masse maximale admissible est égale à la masse du liquide cryogénique occupant 98 % du volume net (3.13) du récipient intérieur (3.4) dans des conditions d'ouverture initiale du dispositif de décharge, le récipient ayant une assiette horizontale et la masse du gaz se trouvant dans les mêmes conditions que celles du volume restant du récipient intérieur.
Note 2 à l'article: L'hélium liquide cryogénique peut occuper 100 % du volume du récipient intérieur à une pression (3.16) quelconque.
3.15 masse brute
somme de la tare (3.12) et de la masse nette (3.14)
3.16 pression
pression effective pression relative à la pression atmosphérique
3.17 citerne fixe
grand récipient (cryogénique) transportable, d'une capacité supérieure à 1 000 l, qui est fixé à demeure à un véhicule (qui devient alors un véhicule-citerne) ou qui fait partie intégrante du châssis de ce véhicule
3.18 citerne démontable
grand récipient transportable non fixé à demeure à un véhicule Note 1 à l'article: Lorsqu'elle est fixée au véhicule de transport, la citerne démontable satisfait aux exigences spécifiées pour une citerne fixe (3.17). Cette citerne est conçue pour être soulevée uniquement à vide.
3.19 citerne mobile
citerne multimodale isolée thermiquement, d'une capacité supérieure à 450 l, qui dispose de l'équipement de service (3.9) et de l'équipement de structure nécessaires au transport de gaz liquéfiés réfrigérés Note 1 à l'article: Cette citerne peut être soulevée pleine, et être chargée et déchargée sans retirer l'élément de structure.
Note 2 à l'article: La liste des gaz liquéfiés réfrigérés est disponible à l'Annexe K.
3.20 pression de service maximale admissible
p s pression (3.16) effective maximale admissible au-dessus du récipient dans sa position de fonctionnement normale
ISO/FDIS 20421-1:2026(fr)
3.21 plaque de décharge
bouchon de décharge plaque ou bouchon retenu par la pression (3.16) atmosphérique, qui permet de décharger l'excès de pression interne, provenant généralement de l'enveloppe à vide isolant
3.22 dispositif à disque de rupture
dispositif de décharge de pression sans fermeture, dont la rupture est déclenchée par la pression (3.16) différentielle Note 1 à l'article: Il s'agit de l'assemblage complet des composants installés comprenant, le cas échéant, le support de disque de rupture.
3.23 récipient à pression renforcée
récipient sous pression qui, après sa réalisation, a été soumis à une pression interne calculée et contrôlée (pression de renforcement), et dont l'épaisseur de paroi est calculée à partir de la contrainte à la pression de renforcement et non à partir de la valeur de contrainte de calcul conventionnelle du matériau utilisé Note 1 à l'article: Les récipients sous pression (3.16) fabriqués à partir d'un matériau traité thermiquement sont soumis à une déformation plastique contrôlée pendant l'opération de renforcement à mesure qu'augmente leur limite d'élasticité. Les récipients sous pression fabriqués à partir d'un matériau écroui sont soumis à une déformation plastique mineure, voire inexistante.
3.24 allongement résiduel
allongement initial de l'acier moins l'allongement créé par la déformation due au formage froid
3.25 essai d'étanchéité
essai utilisant un gaz qui consiste à exposer la coque et son équipement de service (3.9) à une pression (3.16) interne efficace au moins égale à 90 % de la pression de service maximale admissible, sans toutefois excéder la pression de calcul
4 Symboles
Symbole Définition Unité b largeur du renfort de type plaque, anneau ou coque mm c surépaisseur pour corrosion mm d distance mm d diamètre d'ouverture mm
d diamètre extérieur du tube ou du piquage mm a f côté étroit de la plaque rectangulaire ou elliptique mm l longueur du cône entre des raidisseurs efficaces (voir la Figure 5) mm
l ligament (âme) entre deux piquages mm l l′ longueur de flambement mm b, b l longueur de dépassement du renfort du piquage mm s n nombre de lobes — p pression de calcul, telle que définie en 10.3.2.2 — p pression calculée, telle que définie en 10.2.3.2.1 a) bar
p pression externe admissible limitée par le flambement élastique bar e p pression de renforcement bar k p pression du liquide bar L p pression externe admissible limitée par la déformation plastique bar p
ISO/FDIS 20421-1:2026(fr) Symbole Définition Unité p pression effective maximale admissible bar s p pression d'essai (voir 6.2) bar T r rayon, par exemple rayon de carre intérieur de fonds bombés et de cônes mm s épaisseur minimale mm s épaisseur de paroi requise au bord de l'ouverture mm A s épaisseur de paroi réelle mm e s épaisseur de paroi requise à l'extérieur de la zone d'angle mm g s épaisseur du renfort du piquage dans le support mm n s épaisseur de paroi du piquage mm s s épaisseur de paroi requise dans la zone d'angle mm
t dans ce contexte, entraxe entre deux piquages mm x (zone de la longueur de décroissance) distance sur laquelle la contrainte dominante mm est présumée agir x longueurs caractéristiques (i = 1,2,3) permettant de définir la zone d'angle mm
[Figure 10 a) et Figure 10 b) et 10.3.6.5.4] η facteur indicatif de l'utilisation de la contrainte de calcul admissible dans les — assemblages ou facteur tenant compte des affaiblissements
A section d'un élément de renfort mm C, β coefficients de sécurité — D diamètre de la coque mm D diamètre extérieur, par exemple d'une coque cylindrique mm a D diamètre extérieur du cylindre raccordé (voir la Figure 10) mm a1 D diamètre extérieur à un raidissement effectif (voir la Figure 12) mm a2 D diamètre intérieur, par exemple d'une coque cylindrique mm
D diamètre de calcul (voir la Figure 10) mm k D diamètre de la coque au niveau du piquage (voir la Figure 11) mm s
E module de Young N/mm G Point de gravité —
I moment d'inertie de l'élément de renfort mm
R contrainte d'élasticité minimale garantie ou limite conventionnelle d'élasticité à N/mm e 0,2 % à 20 °C (limite conventionnelle d'élasticité à 1 % pour l'acier austénitique)
R résistance à la traction minimale garantie à 20 °C N/mm m
R limite d'élasticité minimale garantie avec une déformation plastique de 1,0 % N/mm p1,0
K propriété de matériau utilisée pour le calcul (voir 10.3.2.3) N/mm
K propriété de matériau à la température T en °C (par exemple K pour une propriété N/mm T 20 de matériau à 20 °C (voir 10.3.2.3.2) R rayon de courbure, par exemple rayon intérieur de bombage d'un fond bombé mm S coefficient de sécurité à la pression de calcul, par rapport à R — e S coefficient de sécurité contre le flambement élastique à la pression de calcul — k S coefficient de sécurité contre la déformation plastique — p Z valeur auxiliaire — v coefficient de Poisson — u ovalisation (voir 11.5.5.2) — φ angle du cône °
σ valeur de contrainte de calcul (valeur de contrainte de renforcement à l'Annexe D) N/mm k
ISO/FDIS 20421-1:2026(fr)
5 Exigences générales
5.1 Les grands récipients cryogéniques transportables doivent résister en toute sécurité aux charges mécaniques et thermiques, ainsi qu'aux effets chimiques rencontrés au cours de l'essai de pression et du fonctionnement normal. Ces exigences sont considérées comme respectées si les conditions des Articles 6 à 12 sont remplies. Le récipient doit être marqué conformément à l'Article 13, soumis à essai conformément à l'Article 14 et utilisé conformément à l'ISO 20421-2.
5.2 Les grands récipients cryogéniques transportables doivent être configurés de telle manière que le récipient puisse être utilisé en toute sécurité (par exemple, robinets, dispositifs de décharge). Le nombre d'ouvertures dans le récipient intérieur de tels équipements doit être réduit autant que possible. 5.3 Le grand récipient cryogénique transportable doit être propre pour le service prévu, conformément à l'ISO 23208.
5.4 Le fabricant doit conserver les documents mentionnés à l'Article 16 ainsi que l'ensemble de la documentation d'accompagnement (y compris celle de ses sous-traitants, le cas échéant) pendant une période spécifiée (par exemple, responsabilité du fait du produit). En outre, le fabricant doit conserver toute la documentation d'accompagnement et de fond (y compris celle de ses sous-traitants, le cas échéant) établissant la conformité du récipient au présent document.
6 Charges mécaniques
6.1 Généralités
Le grand récipient cryogénique transportable doit résister aux charges mécaniques mentionnées en 10.2.3 sans subir une déformation telle qu'elle puisse compromettre la sécurité et entraîner des fuites. Cette exigence peut être validée:
- par calcul;
- par calcul et à l'aide de la méthode du renforcement de pression, si elle est admise;
- par calcul et par méthode expérimentale.
6.2 Charge pendant l'essai de pression
La charge exercée pendant l'essai de pression doit être calculée à l'aide de la Formule (1):
pp13, 1 (1)
Ts où p est la pression d'essai (en bar); T P est la pression maximale admissible (en bar); s +1 est la tolérance pour le vide externe (en bar).
7 Effets chimiques
En raison des températures de fonctionnement et des matériaux de construction, la possibilité d'une action chimique sur les surfaces intérieures en contact avec les fluides cryogéniques peut être négligée. La position du récipient intérieur à l'intérieur d'une enveloppe extérieure évacuée exclut toute possibilité de corrosion extérieure du récipient intérieur et toute possibilité de corrosion des surfaces intérieures de l'enveloppe extérieure. Par conséquent, il n'est pas nécessaire d'aménager des regards dans le récipient intérieur ou dans l'enveloppe extérieure.
ISO/FDIS 20421-1:2026(fr) De même, il n'est pas nécessaire de prévoir une surépaisseur de corrosion sur les surfaces qui sont en contact avec le fluide de service ou qui sont exposées à l'espace de vide entre le récipient intérieur et l'enveloppe extérieure.
Le matériau et la protection des surfaces exposées à l'atmosphère doivent être adaptés à l'usage prévu (par exemple, résistants aux atmosphères industrielles et marines).
8 Conditions thermiques
Les conditions thermiques suivantes doivent être prises en compte:
- pour le récipient intérieur et son équipement associé, la plage de température totale prévue;
- pour l'enveloppe extérieure et son équipement (autre que l'équipement décrit à l'Article 7):
- une température minimale de fonctionnement de −20 °C;
- une température maximale de fonctionnement de 50 °C.
NOTE 1 Certains emplacements imposent une température minimale de fonctionnement plus basse (par exemple −40 °C) et/ou une température maximale de fonctionnement plus élevée (par exemple +65 °C). NOTE 2 Cela ne s'applique pas si l'enveloppe est conçue pour une température plus faible devant être marquée sur la plaque signalétique.
9 Matériaux
9.1 Choix des matériaux
9.1.1 Les matériaux qui sont ou peuvent être en contact avec des fluides cryogéniques doivent être conformes à l'ISO 21010.
...