CISPR 16-4-2:2011/COR1:2013
(Corrigendum)Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty
Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty
Corrigendum 1 - Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de l'instrumentation
General Information
- Status
- Published
- Publication Date
- 10-Apr-2013
- Technical Committee
- CIS/A - Radio-interference measurements and statistical methods
- Current Stage
- PPUB - Publication issued
- Start Date
- 11-Apr-2013
- Completion Date
- 15-Apr-2013
Relations
- Effective Date
- 05-Sep-2023
CISPR 16-4-2:2011/COR1:2013 - Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty Released:4/11/2013
Frequently Asked Questions
CISPR 16-4-2:2011/COR1:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty". This standard covers: Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty
Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrument uncertainty
CISPR 16-4-2:2011/COR1:2013 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
CISPR 16-4-2:2011/COR1:2013 has the following relationships with other standards: It is inter standard links to CISPR 16-4-2:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
CISPR 16-4-2:2011/COR1:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
CISPR 16-4-2 CISPR 16-4-2
(Second edition – 2011) (Deuxième édition – 2011)
Specification for radio disturbance Spécifications des méthodes et des appareils
and immunity measuring apparatus and de mesure des perturbations
methods – radioélectriques et de l'immunité
aux perturbations radioélectriques –
Part 4-2: Uncertainties, statistics
and limit modelling – Partie 4-2: Incertitudes, statistiques
Measurement et modélisation des limites –
instrumentation uncertainty Incertitudes de
mesure de l’instrumentation
CO RRI G E NDUM 1
Table D.3 – Horizontally polarized radiated Tableau D.3 – Perturbations rayonnées
disturbances from 200 MHz to 1 GHz using polarisées horizontalement de 200 MHz à
an LPDA antenna at a distance of 3 m, 10 1 GHz, en utilisant une antenne log-
m, or 30 m périodique à doublet (LPDA) à une
distance de 3 m, 10 m ou 30 m
Add, in the row starting with “Noise floor Ajouter, dans la ligne commençant par
c
proximity”, a new footnote after the value "Rapport signal à bruit du récepteur", une
c
“0,63” in the last column. nouvelle note après la valeur "0,63" de la
dernière colonne.
Add, at the bottom of this table, the Ajouter, à la fin de ce tableau, la nouvelle
c c
following new footnote to table : note de bas de tableau suivante:
...