CISPR 16-4-2:2011/AMD2:2018/COR1:2019
(Amendment)Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
Corrigendum 1 - Amendement 2 - Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de l'instrumentation
General Information
- Status
- Published
- Publication Date
- 15-Jan-2019
- Technical Committee
- CIS/A - Radio-interference measurements and statistical methods
- Current Stage
- PPUB - Publication issued
- Start Date
- 16-Jan-2019
- Completion Date
- 14-Mar-2019
Relations
- Effective Date
- 05-Sep-2023
CISPR 16-4-2:2011/AMD2:2018/COR1:2019 - Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty Released:1/16/2019
Frequently Asked Questions
CISPR 16-4-2:2011/AMD2:2018/COR1:2019 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty". This standard covers: Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
Corrigendum 1 - Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
CISPR 16-4-2:2011/AMD2:2018/COR1:2019 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
CISPR 16-4-2:2011/AMD2:2018/COR1:2019 has the following relationships with other standards: It is inter standard links to CISPR 16-4-2:2011/AMD2:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
CISPR 16-4-2:2011/AMD2:2018/COR1:2019 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
CISPR 16-4-2:2011/AMD2:2018/
COR1:2019 IEC 2019 – 1 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
CISPR 16-4-2 CISPR 16-4-2
Edition 2.0 2011-06 Édition 2.0 2011-06
Amendment 2: 2018-08 Amendement 2:2018-08
Specification for radio disturbance and immunity Spécifications des méthodes et des appareils de
measuring apparatus mesure des perturbations
and methods – radioélectriques et de l'immunité aux
perturbations radioélectriques –
Part 4-2: Uncertainties, statistics and limit
modelling – Measurement Partie 4-2: Incertitudes, statistiques et
instrumentation uncertainty modélisation des limites – Incertitudes
de mesure de l’instrumentation
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
Table B.8 − Conducted disturbances measurements from 150 kHz to 30 MHz using a 150
Ω Δ-AN
Replace the existing values for the input quantity AN Impedance (CM) tolerancesδΖ as
AN-CM
follows:
B26)
δΖ + 5,37/- 3,67 Triangular 1,84
AN Impedance (CM) tolerances
AN-CM
Replace the existing values for the combined standard uncertainty u and the expanded
c
uncertainty (U ) 2 u as follows:
CISPR c
u
Combined standard uncertainty 2,93
c
Expanded uncertainty (U ) 2 u
5,86
CISPR c
B.10 Rationale for the estimates of input quantities specific to the measurement method
using a Δ-AN
Replace the existing second sentence in Superscript B2
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...