Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components - Rules for d.c. circuit-breakers

In addition to the general requirements of IEC 60077-2, it gives the rules for circuit-breakers, the main contacts of which are to be connected to d.c. power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V d.c. according to IEC 60850.

Applications ferroviaires - Equipements électriques du matériel roulant - Partie 3: Composants électrotechniques - Règles pour disjoncteurs à courant continu

Donne en complément des règles générales de la CEI 60077-2, les règles relatives aux disjoncteurs dont les contacts sont destinés à être connectés aux circuits à courant continu de traction et/ou aux circuits des auxiliaires. La tension continue nominale de ces circuits nexcède pas 3 000 V conformément à la CEI 60850.

General Information

Status
Published
Publication Date
18-Dec-2001
Current Stage
DELPUB - Deleted Publication
Start Date
25-Oct-2019
Completion Date
31-Jul-2018
Ref Project

Relations

Standard
IEC 60077-3:2001 - Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components - Rules for d.c. circuit-breakers Released:12/19/2001 Isbn:283186125X
English and French language
53 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
60077-3
INTERNATIONAL
Première édition
STANDARD
First edition
2001-12
Applications ferroviaires –
Equipements électriques du matériel roulant –
Partie 3:
Composants électrotechniques –
Règles pour disjoncteurs à courant continu
Railway applications –
Electric equipment for rolling stock –
Part 3:
Electrotechnical components –
Rules for d.c. circuit-breakers

Numéro de référence
Reference number
CEI/IEC 60077-3:2001
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1

exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and

base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60077-3
INTERNATIONAL
Première édition
STANDARD
First edition
2001-12
Applications ferroviaires –
Equipements électriques du matériel roulant –
Partie 3:
Composants électrotechniques –
Règles pour disjoncteurs à courant continu
Railway applications –
Electric equipment for rolling stock –
Part 3:
Electrotechnical components –
Rules for d.c. circuit-breakers

 IEC 2001 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
U
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60077-3 © CEI:2001
SOMMAIRE
AVANT-PROPOS .6

1 Domaine d'application et objet .10

2 Références normatives .12

3 Définitions .14

3.1 Composants .14

3.2 Parties de composant .14

3.3 Caractéristiques de fonctionnement .16
3.4 Caractéristiques de coupure .18
4 Classification .22
5 Caractéristiques.22
5.1 Liste des caractéristiques .22
5.2 Type de disjoncteur .22
5.3 Valeurs limites et valeurs assignées du circuit principal.22
5.3.1 Généralités .22
5.3.2 Tensions assignées .24
5.3.3 Courants assignés .24
5.3.4 Constantes de temps assignées.24
5.3.5 Caractéristiques en court-circuit (voir aussi annexe B) .24
5.4 Fréquences de fonctionnement .26
5.5 Circuits de commande électriques et pneumatiques .26
5.6 Circuits auxiliaires électriques et pneumatiques .26
5.7 Déclencheur à maximum de courant .26
5.8 Valeurs crêtes de la tension d’arc .26
6 Information sur le produit .28
6.1 Documentation sur le composant .28
6.2 Marquage .28
7 Conditions normales de service .28
8 Dispositions relatives à la construction et au fonctionnement.28
8.1 Dispositions constructives.28
8.2 Exigences relatives au fonctionnement .28
8.2.1 Conditions de fonctionnement .28

8.2.2 Echauffements.28
8.2.3 Fonctionnement à la mise en service .28
8.2.4 Compatibilité électromagnétique (CEM).28
8.2.5 Emission de bruit acoustique .30
8.2.6 Propriétés diélectriques .30
8.2.7 Surtensions de coupure .30
8.2.8 Aptitude au fonctionnement en service .30
8.2.9 Aptitude à supporter les vibrations et les chocs .32
8.2.10 Aptitude à l’établissement et à la coupure en court-circuit.32
9 Essais .32
9.1 Nature des essais.32
9.1.1 Généralités .32
9.1.2 Essais de type .32

60077-3 © IEC:2001 – 3 –
CONTENTS
FOREWORD.7

1 Scope and object .11

2 Normative references.13

3 Definitions .15

3.1 Components .15

3.2 Component parts .15

3.3 Operational features .17
3.4 Breaking characteristics.19
4 Classification .23
5 Characteristics.23
5.1 List of characteristics.23
5.2 Type of circuit-breaker.23
5.3 Rated values and limiting values for the main circuit.23
5.3.1 General .23
5.3.2 Rated voltages.25
5.3.3 Rated currents .25
5.3.4 Rated time constants .25
5.3.5 Short-circuit characteristics (see also annex B) .25
5.4 Operational frequencies.27
5.5 Electric and pneumatic control circuits .27
5.6 Electric and pneumatic auxiliary circuits .27
5.7 Over-current release.27
5.8 Peak arc voltages .27
6 Product information.29
6.1 Component documentation .29
6.2 Marking .29
7 Normal service conditions .29
8 Constructional and performance requirements .29
8.1 Constructional requirements .29
8.2 Performance requirements.29
8.2.1 Operating conditions .29

8.2.2 Temperature rise .29
8.2.3 Operation following inactivity.29
8.2.4 Electromagnetic compatibility (EMC) .29
8.2.5 Acoustic noise emission.31
8.2.6 Dielectric properties .31
8.2.7 Switching overvoltages .31
8.2.8 Operational performance capability .31
8.2.9 Ability to withstand vibration and shock .33
8.2.10 Ability to make and break under short-circuit conditions.33
9 Tests .33
9.1 Kinds of tests.33
9.1.1 General .33
9.1.2 Type tests.33

– 4 – 60077-3 © CEI:2001
9.1.3 Essais de série .32

9.1.4 Essais d’investigation.34

9.2 Vérification des dispositions constructives .34

9.2.1 Généralités .34

9.2.2 Essais de type .34

9.2.3 Essais de série .34

9.3 Essais de type pour la vérification des dispositions relatives au

fonctionnement.34

9.3.1 Séquences d’essais .34

9.3.2 Conditions générales d'essais .36

9.3.3 Séquence d’essai I: caractéristiques générales de fonctionnement .38
9.3.4 Séquence d’essai II: établissement et coupure assignés en court-
circuit .40
9.3.5 Séquence d’essai III: aptitude à supporter les vibrations et les chocs .44
9.3.6 Séquence d’essai IV: recherche des courants critiques .44
9.3.7 Séquence d’essai V: conditions climatiques.46
9.3.8 Séquence d’essai VI: autres essais .46
9.4 Essais de série pour la vérification des exigences relatives au fonctionnement.46
9.4.1 Généralités .46
9.4.2 Fonctionnement mécanique .46
9.4.3 Etalonnage des déclencheurs .46
9.4.4 Tenue diélectrique .46
9.4.5 Etanchéité (pour les disjoncteurs à air comprimé) .46
Annexe A (normative) Circuit d’essai pour la vérification des pouvoirs de fermeture et
de coupure.48
Annexe B (informative) Vérification des pouvoirs de fermeture et de coupure
en court-circuit .50
Figure A.1 – Schéma du circuit d'essai .26
Figure B.1 – Etalonnage du circuit pour obtenir la valeur crête du courant présumé .27
Figure B.2 – Oscillogramme correspondant à une coupure du courant après le passage
de sa valeur maximale .52
Figure B.3 – Oscillogramme correspondant à la coupure du courant avant sa valeur
maximale (courant limité par le disjoncteur).52

Tableau 1 – Constantes de temps assignées.24
Tableau 2 – Aptitude au fonctionnement.30
Tableau 3 – Liste des séquences d’essais de type pour les dispositions
relatives au fonctionnement.36
Tableau 4 – Tolérances des grandeurs d’essai .38

60077-3 © IEC:2001 – 5 –
9.1.3 Routine tests .33

9.1.4 Investigatory tests.35

9.2 Verification of constructional requirements.35

9.2.1 General .35

9.2.2 Type tests.35

9.2.3 Routine tests .35

9.3 Type tests for verification of performance requirements .35

9.3.1 Test sequences .35

9.3.2 General test conditions .37

9.3.3 Test sequence I: general performance characteristics .39

9.3.4 Test sequence II: rated short-circuit making and breaking capacities.41
9.3.5 Test sequence III: capability to withstand vibration and shock.45
9.3.6 Test sequence IV: searching for critical currents .45
9.3.7 Test sequence V: climatic conditions.47
9.3.8 Test sequence VI: other tests.47
9.4 Routine tests for verification of performance requirements .47
9.4.1 General .47
9.4.2 Mechanical operation .47
9.4.3 Calibration of releases .47
9.4.4 Dielectric withstand.47
9.4.5 Air-tightness (for pneumatic circuit-breaker) .47
Annex A (normative) Test circuit to verify the making and breaking capacities .49
Annex B (informative) Verification of short-circuit making and breaking capacities .51
Figure A.1 – Diagram of the test circuit.26
Figure B.1 – Calibration of the circuit to obtain the prospective peak making current.27
Figure B.2 – Oscillogram corresponding to a break after the current has passed its
maximum value.53
Figure B.3 – Oscillogram corresponding to a break before the current has reached its
maximum value (current limiting circuit-breaker).53
Table 1 – Rated time constants .25
Table 2 – Operational performance capability .31
Table 3 – List of type test sequences for performance requirements .37

Table 4 – Tolerances on test values .39

– 6 – 60077-3 © CEI:2001
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
APPLICATIONS FERROVIAIRES –
ÉQUIPEMENTS ÉLECTRIQUES DU MATÉRIEL ROULANT –

Partie 3: Composants électrotechniques –

Règles pour disjoncteurs à courant continu

AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence
La Norme internationale CEI 60077-3 a été établie par le comité d'études 9 de la CEI: Matériel
électrique ferroviaire.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
9/651/FDIS 9/666/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Elle doit être lue conjointement avec la CEI 60077-1 et la CEI 60077-2.
L'annexe A fait partie intégrante de cette norme.
L'annexe B est donnée uniquement à titre d'information.

60077-3 © IEC:2001 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
RAILWAY APPLICATIONS –
ELECTRIC EQUIPMENT FOR ROLLING STOCK –

Part 3: Electrotechnical components –

Rules for d.c. circuit-breakers

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60077-3 has been prepared by IEC technical committee 9: Electric
railway equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
9/651/FDIS 9/666/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
This standard should be read in conjunction with IEC 60077-1 and IEC 60077-2.
Annex A forms an integral part of this standard.
Annex B is given for information only.

– 8 – 60077-3 © CEI:2001
La CEI 60077 comprend les parties suivantes, présentées sous le titre général Applications
ferroviaires – Equipements électriques du matériel roulant:

– Partie 1 – Conditions générales de service et règles générales

– Partie 2 – Composants électrotechniques – Règles générales

– Partie 3 – Composants électrotechniques – Règles pour disjoncteurs à courant continu

– Partie 4 – Composants électrotechniques – Règles pour disjoncteurs à courant mono-

1)
phasé
1)
– Partie 5 – Composants électrotechniques – Règles pour coupe-circuit à haute tension

Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2008. A cette
date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
___________
1)
En préparation.
60077-3 © IEC:2001 – 9 –
IEC 60077 consists of the following parts under the general title Railway applications – Electric
equipment for rolling stock:
– Part 1 – General service conditions and general rules

– Part 2 – Electrotechnical components – General rules

– Part 3 – Electrotechnical components – Rules for d.c. circuit-breakers

1)
– Part 4 – Electrotechnical components – Rules for a.c. circuit-breakers

1)
– Part 5 – Electrotechnical components – Rules for HV fuses

The committee has decided that the contents of this publication will remain unchanged until

2008. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
___________
1)
In preparation.
– 10 – 60077-3 © CEI:2001
APPLICATIONS FERROVIAIRES –
ÉQUIPEMENTS ÉLECTRIQUES DU MATÉRIEL ROULANT –

Partie 3: Composants électrotechniques –

Règles pour disjoncteurs à courant continu

1 Domaine d'application et objet

La présente partie de la CEI 60077 donne en complément des règles générales de la
CEI 60077-2, les règles relatives aux disjoncteurs dont les contacts sont destinés à être
connectés aux circuits à courant continu de traction et/ou aux circuits des auxiliaires. La
tension continue nominale de ces circuits n’excède pas 3 000 V conformément à la CEI 60850.
En complément de la CEI 60077-2, cette partie de la CEI 60077 précise particulièrement
a) les caractéristiques des disjoncteurs;
b) les conditions de service que les disjoncteurs doivent supporter du point de vue
– du fonctionnement et du comportement en service normal;
– du fonctionnement et du comportement en cas de court-circuit;
– des propriétés diélectriques;
c) les essais de conformité des composants avec les caractéristiques dans les conditions de
service ainsi que les méthodes d’essai correspondantes à utiliser;
d) les informations à donner ou à marquer sur l’appareil.
NOTE 1 Les disjoncteurs qui font l’objet de cette partie de la CEI 60077 peuvent être équipés de dispositifs
d’ouverture automatique dans des conditions prédéterminées autres que celles de la surcharge, comme une
tension insuffisante ou l’inversion du courant par exemple. Cette partie de la CEI 60077 ne traite pas de la
vérification de tels fonctionnements dans de telles conditions prédéterminées.
NOTE 2 L’incorporation de composants électroniques ou de sous-ensembles électroniques dans les composants
électrotechniques est maintenant une pratique courante.
Bien que la présente norme ne soit pas applicable aux matériels électroniques, la présence de composants
électroniques n’est pas une raison suffisante pour exclure ces composants électrotechniques du champ d’appli-
cation de cette norme.
Il convient que les sous-ensembles électroniques inclus dans les disjoncteurs soient conformes à la norme
correspondante applicable à l’électronique (CEI 60571).
NOTE 3 Après accord entre l'utilisateur et le fabricant, certaines de ces règles peuvent être utilisées pour l’appa-
reillage électrique installé dans des véhicules autres que ceux du matériel roulant ferroviaire tels que les
locomotives de mine, les trolleybus, etc. Dans ce cas particulier, des prescriptions complémentaires peuvent être
nécessaires.
Cette norme ne couvre pas
a) l'assemblage de composants électrotechniques destinés à des fonctions particulières;
b) les disjoncteurs industriels spécifiés par la CEI 60947-2;
c) les disjoncteurs à courant continu des installations fixes spécifiés par la CEI 61992-2.

60077-3 © IEC:2001 – 11 –
RAILWAY APPLICATIONS –
ELECTRIC EQUIPMENT FOR ROLLING STOCK –

Part 3: Electrotechnical components –

Rules for d.c. circuit-breakers

1 Scope and object
In addition to the general requirements of IEC 60077-2, this part of IEC 60077 gives the rules
for circuit-breakers, the main contacts of which are to be connected to d.c. power and/or
auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V d.c. according
to IEC 60850.
This part of IEC 60077, together with IEC 60077-2, states specifically
a) the characteristics of the circuit-breakers;
b) the service conditions with which circuit-breakers have to comply with reference to
– operation and behaviour in normal service;
– operation and behaviour in the case of short circuit;
– dielectric properties;
c) the tests for confirming the compliance of the components with the characteristics under
the service conditions and the methods to be adopted for these tests;
d) the information to be marked on, or given with, the circuit breaker.
NOTE 1 Circuit-breakers which are dealt with in this part of IEC 60077 may be provided with devices for automatic
opening under predetermined conditions other than those of over-current, for example, under-voltage and reversal
of power current. This part of IEC 60077 does not deal with the verification of operation under such predetermined
conditions.
NOTE 2 The incorporation of electronic components or electronic sub-assemblies into electrotechnical components is
now common practice.
Although this standard is not applicable to electronic equipment, the presence of electronic components does not
provide a reason to exclude such electrotechnical components from the scope.
Electronic sub-assemblies included in circuit-breakers should comply with the relevant standard for electronics
(IEC 60571).
NOTE 3 Certain of these rules may, after agreement between the user and the manufacturer, be used for electro-
technical components installed on vehicles other than rail rolling stock such as mine locomotives, trolleybuses, etc.
In this case, particular additional requirements may be necessary.
This standard does not cover
a) multi-connection of electro-technical components to achieve a particular duty;
b) industrial circuit-breakers which have to comply with IEC 60947-2;
c) d.c. circuit-breakers for fixed installations which have to comply with IEC 61992-2.

– 12 – 60077-3 © CEI:2001
Pour b) et c) dans le but d’obtenir un fonctionnement satisfaisant, il convient d’employer la
présente norme uniquement pour spécifier les prescriptions particulières relatives à l’appli-

cation ferroviaire. Dans de tels cas, il convient d'indiquer dans un document spécifique les

exigences complémentaires auxquelles il faut que les composants industriels ou les

disjoncteurs pour installations fixes satisfassent, par exemple:

– pour être adaptés (tension de commande, conditions d’environnement, etc.);

– pour être installés et utilisés de sorte qu’ils n’aient pas à subir les conditions particulières

du milieu ferroviaire;
– pour subir des essais complémentaires afin de prouver que ces composants peuvent

supporter de façon satisfaisante les conditions du matériel roulant.

2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 60077.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications ne
s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente partie de
la CEI 60077 sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes
des documents normatifs indiqués ci-après. Pour les références non datées, la dernière édition
du document normatif en référence s’applique. Les membres de la CEI et de l'ISO possèdent
le registre des Normes internationales en vigueur.
CEI 60050(441):1984, Vocabulaire Electrotechnique International – Appareillage et fusibles
CEI 60077-1:1999, Applications ferroviaires – Equipements électriques du matériel roulant –
Partie 1: Conditions générales de service et règles générales
CEI 60077-2:1999, Applications ferroviaires – Equipements électriques du matériel roulant –
Partie 2: Composants électrotechniques – Règles générales
CEI 60529:1989, Degrés de protection procurés par les enveloppes (Code IP)
CEI 60571:1998, Equipements électroniques utilisés sur les véhicules ferroviaires
CEI 60850:2000, Applications ferroviaires – Tensions d’alimentation des systèmes de traction
CEI/TR3 60943:1998, Guide concernant l'échauffement admissible des parties des matériels
électriques, en particulier les bornes de raccordement

CEI 60947-2:1989, Appareillage à basse tension – Deuxième partie: Disjoncteurs
CEI 61373:1999, Applications ferroviaires – Matériel roulant – Essais de chocs et vibrations
CEI 61992-2:2001, Applications ferroviaires – Installations fixes – Appareillage en courant
continu – Partie 2: Disjoncteurs

60077-3 © IEC:2001 – 13 –
For b) and c), in order to ensure satisfactory operation, this standard should be used to specify
only the particular requirements for rolling stock. In such cases, a specific document should

state the additional requirements with which the industrial or fixed installations circuits breakers

are to comply, for example:
– either to be adapted (for example, for control voltage, environmental conditions, etc.);

– or to be installed and used in such a way that they do not have to endure specific rolling

stock conditions;
– or to be additionally tested to prove that these components can withstand satisfactorily the

rolling stock conditions.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 60077. For dated references, subsequent amendments
to, or revisions of, any of these publications do not apply. However, parties to agreements
based on this part of IEC 60077 are encouraged to investigate the possibility of applying the
most recent editions of the normative documents indicated below. For undated references, the
latest edition of the normative document referred to applies. Members of IEC and ISO maintain
registers of currently valid International Standards.
IEC 60050(441):1984, International Electrotechnical Vocabulary – Switchgear, controlgear and
fuses
IEC 60077-1:1999, Railway applications – Electric equipment for rolling stock – Part 1: General
service conditions and general rules
IEC 60077-2:1999; Railway applications – Electric equipment for rolling stock – Part 2:
Electrotechnical components – General rules
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60571:1998, Electronic equipment used on rail vehicles
IEC 60850:2000, Railway applications – Supply voltage of traction systems
IEC/TR3 60943:1998, Guidance concerning the permissible temperature rise for parts of
electrical equipment, in particular for terminals

IEC 60947-2:1989, Low-voltage switchgear and controlgear – Part 2: Circuit-breakers
IEC 61373:1999, Railway applications – Rolling stock equipment – Shock and vibration tests
IEC 61992-2:2001, Railway applications – Fixed installations – DC switchgear – Part 2: Circuit-
breakers
– 14 – 60077-3 © CEI:2001
3 Définitions
Pour les besoins de la présente partie de la CEI 60077, les définitions données dans les

articles 3 de la CEI 60077-1 et de la CEI 60077-2 sont applicables avec les définitions complé-

mentaires ci-après.
3.1 Composants
3.1.1
disjoncteur polarisé
disjoncteur pour lequel les caractéristiques de coupure ne sont définies que pour une direction
du courant dans le circuit principal
3.1.2
disjoncteur bidirectionnel
disjoncteur pour lequel les caractéristiques de coupure sont les mêmes dans les deux sens de
circulation du courant dans le circuit principal
3.1.3
disjoncteur à air
disjoncteur dont les contacts s’ouvrent et se ferment dans l’air à la pression atmosphérique
[VEI 441-14-27]
3.1.4
disjoncteur à semi-conducteur
disjoncteur conçu pour établir et interrompre le courant dans un circuit au moyen de semi-
conducteurs
3.1.5
disjoncteur hybride
disjoncteur muni de contacts mécaniques pour l'isolement associés à un semi-conducteur pour
la coupure
NOTE Les disjoncteurs à semi-conducteur sans contact mécanique pour l'isolement ne sont pas utilisés sur le
matériel roulant.
3.2 Parties de composant
3.2.1
déclencheur
dispositif raccordé mécaniquement à un appareil mécanique de connexion dont il libère les
organes de retenue et qui permet l’ouverture ou la fermeture du disjoncteur.
[VEI 441-15-17 modifié]
NOTE 1 Un disjoncteur peut avoir plusieurs déclencheurs, chacun d’eux fonctionnant dans des conditions
spécifiées.
NOTE 2 Un déclencheur peut être composé de parties mécaniques, électromagnétiques ou électroniques.
3.2.1.1
déclencheur à maximum de courant (instantané)
déclencheur qui provoque une manœuvre de déclenchement sans retard intentionnel lorsque le
courant dans le déclencheur est supérieur à la valeur spécifiée
[VEI 441-16-32, modifiée]
60077-3 © IEC:2001 – 15 –
3 Definitions
For the purpose of this part of IEC 60077, the definitions given in clauses 3 of IEC 60077-1 and

IEC 60077-2 are applicable together with the following additional definitions.

3.1 Components
3.1.1
polarized circuit-breaker
circuit-breaker for which the breaking characteristics are defined for only one prescribed

direction of current in the main circuit
3.1.2
bi-directional circuit-breaker
circuit-breaker for which the breaking characteristics are the same for both directions of current
in main circuit
...