Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

Corrigendum 1 - Spécification des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Emplacements d'étalonnage d'antenne et emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz

General Information

Status
Published
Publication Date
30-Aug-2020
Current Stage
PPUB - Publication issued
Start Date
31-Aug-2020
Completion Date
01-Oct-2020

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

CISPR 16-1-5:2014/COR1:2020 - Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz Released:8/31/2020

English and French language (2 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

TL 9000 QuEST Forum

Telecommunications quality management system.

ANAB United States Verified

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

Sponsored listings

Frequently Asked Questions

CISPR 16-1-5:2014/COR1:2020 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz". This standard covers: Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

CISPR 16-1-5:2014/COR1:2020 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

CISPR 16-1-5:2014/COR1:2020 has the following relationships with other standards: It is inter standard links to CISPR 16-1-5:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

CISPR 16-1-5:2014/COR1:2020 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


 IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
CISPR 16-1-5 CISPR 16-1-5
Edition 2.0  2014-12 Édition 2.0  2014-12

Specification for radio disturbance and immunity Spécification des méthodes et des appareils de
measuring apparatus and methods – mesure des perturbations
radioélectriques et de l'immunité aux
Part 1-5: Radio disturbance and immunity perturbations radioélectriques –
measuring apparatus – Antenna calibration
sites and reference test sites for 5 MHz to Partie 1-5: Appareils de mesure des
18 GHz perturbations radioélectriques et de l'immunité
aux perturbations radioélectriques –
Emplacements d'étalonnage d'antenne et
emplacements d'essai de référence pour la plage
comprise entre 5 MHz et 18 GHz

CO RRI G E NDUM 1
A.4.2.3 Acceptance criteria A.4.2.3 Critère d'acceptation
Replace, in the third paragraph, the value Remplacer, dans le troisième alinéa, la
for the allowed tolerance "0,025 m" with valeur de la tolérance
...